{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,27]],"date-time":"2026-09-27T22:43:39Z","timestamp":1790549019179,"version":"4.1.0"},"reference-count":43,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2015,3,1]],"date-time":"2015-03-01T00:00:00Z","timestamp":1425168000000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BioMed Eng OnLine"],"published-print":{"date-parts":[[2015,12]]},"DOI":"10.1186\/s12938-015-0011-y","type":"journal-article","created":{"date-parts":[[2015,2,28]],"date-time":"2015-02-28T04:15:58Z","timestamp":1425096958000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":55,"title":["A flexible and low power telemetric sensing and monitoring system for chronic wound diagnostics"],"prefix":"10.1186","volume":"14","author":[{"given":"Nasir","family":"Mehmood","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alex","family":"Hariz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sue","family":"Templeton","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nicolas H","family":"Voelcker","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2015,3,1]]},"reference":[{"key":"11_CR1","doi-asserted-by":"crossref","first-page":"44","DOI":"10.7748\/ns2011.11.26.11.44.c8821","volume":"26","author":"J Cadogan","year":"2011","unstructured":"Cadogan J, Baldwin D, Carpenter S, Davey J, Harris H, Purser K, et al.: Identification, diagnosis and treatment of wound infection. Nurs Stand 2011, 26: 44\u201348. 10.7748\/ns2011.11.26.11.44.c8821","journal-title":"Nurs Stand"},{"key":"11_CR2","volume-title":"Evidence-Based Wound Surveillance-A Three-Dimensional Approach To Measuring, Imaging and Documenting Wounds","author":"MD Nixon Mark","year":"2014","unstructured":"Nixon Mark MD, Christine M. \u201cEvidence-Based Wound Surveillance-A Three-Dimensional Approach To Measuring, Imaging and Documenting Wounds,\u201d Aranz Medical 2014."},{"key":"11_CR3","unstructured":"The Economic Cost of Wounds. 2014. Available: http:\/\/www.smith-nephew.com\/about-us\/what-we-do\/advanced-wound-management\/economic-cost-of-wounds\/., The Economic Cost of Wounds. 2014. Available: . http:\/\/www.smith-nephew.com\/about-us\/what-we-do\/advanced-wound-management\/economic-cost-of-wounds\/"},{"key":"11_CR4","unstructured":"Wound Management Innovation CRC. 2013. Available: http:\/\/www.woundcrc.com\/mediareleases.html., Wound Management Innovation CRC. 2013. Available: . http:\/\/www.woundcrc.com\/mediareleases.html"},{"key":"11_CR5","volume-title":"Bacteria and wound healing vol. 17","author":"KG Harding","year":"2004","unstructured":"Harding KG, Edwards R: Bacteria and wound healing vol. 17. Lippincott Williams & Wilkins, United States; 2004."},{"key":"11_CR6","doi-asserted-by":"crossref","first-page":"19","DOI":"10.1016\/j.clindermatol.2006.12.005","volume":"25","author":"NB Menke","year":"2007","unstructured":"Menke NB, Ward KR, Witten TM, Bonchev DG, Diegelmann RF: Impaired wound healing. Clin Dermatol 2007, 25: 19\u201325. 10.1016\/j.clindermatol.2006.12.005","journal-title":"Clin Dermatol"},{"key":"11_CR7","volume-title":"Factors affecting wound healing vol. 89","author":"LA Dipietro","year":"2010","unstructured":"Dipietro LA, Guo S: Factors affecting wound healing vol. 89. Sage Publications Inc, United States; 2010."},{"key":"11_CR8","unstructured":"Higher wound care costs are driving treatment research (McKnight\u2019s Long-Term Care News, published in Jun, 2012 Issue). 2014. Available: http:\/\/www.mcknights.com\/higher-wound-care-costs-are-driving-treatment-research\/article\/244578\/"},{"key":"11_CR9","doi-asserted-by":"crossref","first-page":"491","DOI":"10.1016\/j.mpsur.2011.06.007","volume":"29","author":"T Abdelrahman","year":"2011","unstructured":"Abdelrahman T, Newton H: \u201cWound dressings: principles and practice\u201d. Surgery (Oxford) 2011, 29: 491\u2013495. 10.1016\/j.mpsur.2011.06.007","journal-title":"Surgery (Oxford)"},{"key":"11_CR10","first-page":"600","volume":"34","author":"H Partsch","year":"2008","unstructured":"Partsch H, Clark M, Mosti G, Steinlechner E, Schuren J, Abel M, et al.: \u201cClassification of compression bandages: practical aspects\u201d. Dermatol Surg 2008, 34: 600\u2013609.","journal-title":"Dermatol Surg"},{"key":"11_CR11","doi-asserted-by":"crossref","first-page":"576","DOI":"10.1136\/bmj.315.7108.576","volume":"315","author":"A Fletcher","year":"1997","unstructured":"Fletcher A, Cullum N, Sheldon TA: A systematic review of compression treatment for venous leg ulcers. Br Med J 1997, 315: 576. 10.1136\/bmj.315.7108.576","journal-title":"Br Med J"},{"key":"11_CR12","unstructured":"Hopkins A. \u201cHow to apply effective multilayer compression bandaging.\u201d 2006. Wound Essentials (Wounds UK), vol. 1."},{"key":"11_CR13","doi-asserted-by":"crossref","first-page":"115","DOI":"10.1016\/j.jtv.2012.09.002","volume":"21","author":"B Kumar","year":"2012","unstructured":"Kumar B, Das A, Alagirusamy R: Analysis of sub-bandage pressure of compression bandages during exercise. J Tissue Viability 2012, 21: 115\u2013124. 10.1016\/j.jtv.2012.09.002","journal-title":"J Tissue Viability"},{"key":"11_CR14","doi-asserted-by":"crossref","first-page":"33","DOI":"10.1016\/j.clindermatol.2006.09.003","volume":"25","author":"LG Ovington","year":"2007","unstructured":"Ovington LG: Advances in wound dressings. Clin Dermatol 2007, 25: 33\u201338. 10.1016\/j.clindermatol.2006.09.003","journal-title":"Clin Dermatol"},{"key":"11_CR15","doi-asserted-by":"crossref","first-page":"366","DOI":"10.1016\/j.nurpra.2010.01.025","volume":"6","author":"G Lagana","year":"2010","unstructured":"Lagana G, Anderson EH: \u201cMoisture dressings: the new standard in wound care\u201d. J Nurse Pract 2010, 6: 366\u2013370. 10.1016\/j.nurpra.2010.01.025","journal-title":"J Nurse Pract"},{"key":"11_CR16","volume-title":"Diagnostics and wounds","author":"K Harding","year":"2007","unstructured":"Harding K: Diagnostics and wounds. A consensus document, World Union of Wound Healing Societies (WUWHS); 2007."},{"key":"11_CR17","doi-asserted-by":"crossref","first-page":"30","DOI":"10.1016\/j.bios.2012.09.029","volume":"41","author":"TR Dargaville","year":"2013","unstructured":"Dargaville TR, Farrugia BL, Broadbent JA, Pace S, Upton Z, Voelcker NH: \u201cSensors and imaging for wound healing: a review. Biosensors Bioelectronics 2013, 41: 30\u201342. 10.1016\/j.bios.2012.09.029","journal-title":"Biosensors Bioelectronics"},{"key":"11_CR18","doi-asserted-by":"crossref","first-page":"3533","DOI":"10.1109\/IECON.2011.6119881","volume-title":"IECON 2011 - 37th Annual Conference on IEEE Industrial Electronics Society","author":"G Matzeu","year":"2011","unstructured":"Matzeu G, Losacco M, Parducci E, Pucci A, Dini V, Romanelli M. \u201cSkin temperature monitoring by a wireless sensor,\u201d in IECON 2011 - 37th Annual Conference on IEEE Industrial Electronics Society, 2011, pp. 3533\u2013 3535"},{"key":"11_CR19","doi-asserted-by":"crossref","first-page":"1349","DOI":"10.1109\/JMEMS.2007.908437","volume":"16","author":"Y Moser","year":"2007","unstructured":"Moser Y, Gijs Martin AM: Miniaturized flexible temperature sensor. J Microelectromech Syst 2007, 16: 1349\u20131354. 10.1109\/JMEMS.2007.908437","journal-title":"J Microelectromech Syst"},{"key":"11_CR20","doi-asserted-by":"crossref","first-page":"316","DOI":"10.1016\/j.ijsu.2007.02.008","volume":"5","author":"D McColl","year":"2007","unstructured":"McColl D, Cartlidge B, Connolly P: Real-time monitoring of moisture levels in wound dressings in vitro: An experimental study. Int J Surg 2007, 5: 316\u2013322. 10.1016\/j.ijsu.2007.02.008","journal-title":"Int J Surg"},{"key":"11_CR21","unstructured":"Ohmedics Ltd. WoundSense product information. 2014. Available: http:\/\/www.ohmedics.com\/resources\/IFU3+Eng+A6+v1.1+Aug+11.pdf., Ohmedics Ltd. WoundSense product information. 2014. Available: . http:\/\/www.ohmedics.com\/resources\/IFU3+Eng+A6+v1.1+Aug+11.pdf"},{"key":"11_CR22","first-page":"430","volume-title":"Biomedical Engineering (ICoBE)","author":"J Al Khaburi","year":"2012","unstructured":"Al Khaburi J, Dehghani-Sanij A, Nelson EA, Hutchinson J et al. \u201cPressure mapping bandage prototype: Development and testing,\u201d in Biomedical Engineering (ICoBE), 2012 International Conference on, 2012, pp. 430\u2013435."},{"key":"11_CR23","first-page":"41","volume-title":"Sensors Applications Symposium (SAS)","author":"V Casey","year":"2010","unstructured":"Casey V, McAree B, Moloney MC, Grace P. \u201cWearable sub-bandage pressure measurement system,\u201d in Sensors Applications Symposium (SAS), 2010 IEEE, 2010, pp. 41\u201345."},{"key":"11_CR24","unstructured":"Codman Microsensor and ICP Transducer. 2014. Available: http:\/\/emea.depuysynthes.com\/hcp\/codman-neuro\/products\/qs\/icp-monitoring-system., Codman Microsensor and ICP Transducer. 2014. Available: . http:\/\/emea.depuysynthes.com\/hcp\/codman-neuro\/products\/qs\/icp-monitoring-system"},{"key":"11_CR25","doi-asserted-by":"crossref","first-page":"589","DOI":"10.12968\/jowc.2012.21.12.589","volume":"21","author":"J Mejzlik","year":"2012","unstructured":"Mejzlik J: Use of a silicon microsensor for pressure monitoring inside the wound and outcomes on healing. J Wound Care 2012, 21: 589. 10.12968\/jowc.2012.21.12.589","journal-title":"J Wound Care"},{"key":"11_CR26","doi-asserted-by":"crossref","first-page":"1338","DOI":"10.1109\/JMEMS.2012.2206072","volume":"21","author":"N Xue","year":"2012","unstructured":"Xue N, Chang SP, Lee JB: A SU-8-based microfabricated implantable inductively coupled passive RF wireless intraocular pressure sensor. J Microelectromech Syst 2012, 21: 1338\u20131346. 10.1109\/JMEMS.2012.2206072","journal-title":"J Microelectromech Syst"},{"key":"11_CR27","first-page":"2430","volume-title":"26th Annual International Conference of the IEEE, 2004","author":"FE Sauser","year":"2004","unstructured":"Sauser FE, Glos D, Bylski-Austrow D, Papautsky I: \u201cPressure sensors for in vivo measurements on spinal growth plates,\u201d in Engineering in Medicine and Biology Society, IEMBS \u201904. 26th Annual International Conference of the IEEE, 2004 2004, 2430\u20132433."},{"key":"11_CR28","volume-title":"Annual International Conference of the IEEE Engineering in Medicine and Biology Society, United States","author":"I Clausen","year":"2011","unstructured":"Clausen I, Moe ST, Tvedt LGW, Vogl A, Wang DT. \u201cA miniaturized pressure sensor with inherent biofouling protection designed for in vivo applications,\u201d in Annual International Conference of the IEEE Engineering in Medicine and Biology Society, United States, 2011"},{"key":"11_CR29","doi-asserted-by":"crossref","first-page":"819","DOI":"10.1007\/s10544-012-9661-8","volume":"14","author":"W Hasenkamp","year":"2012","unstructured":"Hasenkamp W, Forchelet D, Pataky K, Villard J, Lintel HV, Bertsch A, et al.: Polyimide\/SU-8 catheter-tip MEMS gauge pressure sensor. Biomed Microdevices 2012, 14: 819\u2013828. 10.1007\/s10544-012-9661-8","journal-title":"Biomed Microdevices"},{"key":"11_CR30","doi-asserted-by":"crossref","first-page":"52","DOI":"10.1016\/j.sna.2007.04.047","volume":"138","author":"GC Hill","year":"2007","unstructured":"Hill GC, Melamud R, Declercq FE, Davenport AA, Chan IH, Hartwell PG, et al.: SU-8 MEMS Fabry-Perot pressure sensor. Sensors Actuators A Phys 2007, 138: 52\u201362. 10.1016\/j.sna.2007.04.047","journal-title":"Sensors Actuators A Phys"},{"key":"11_CR31","volume-title":"A wireless microsystem for the remote sensing of pressure, temperature, and relative humidity","author":"AD DeHennis","year":"2005","unstructured":"DeHennis AD, Wise KD. \u201cA wireless microsystem for the remote sensing of pressure, temperature, and relative humidity.\u201d 2005; 14."},{"key":"11_CR32","doi-asserted-by":"crossref","first-page":"S98","DOI":"10.1088\/0960-1317\/17\/7\/S06","volume":"17","author":"R Schlierf","year":"2007","unstructured":"Schlierf R, Horst U, Ruhl M, Schmitz-Rode T, Mokwa W, Schnakenberg U, et al.: A fast telemetric pressure and temperature sensor system for medical applications. J Micromech Microeng 2007, 17: S98-S102. 10.1088\/0960-1317\/17\/7\/S06","journal-title":"J Micromech Microeng"},{"key":"11_CR33","volume-title":"J Biomed Mater ResPart B: Appl Biomater","author":"N Mehmood","year":"2013","unstructured":"Mehmood N, Hariz A, Fitridge R, Voelcker NH. \u201cApplications of modern sensors and wireless technology in effective wound management.\u201d J Biomed Mater ResPart B: Appl Biomater, pp. n\/a-n\/a, 2013."},{"key":"11_CR34","first-page":"20","volume-title":"Australian Biomedical Engineering Conference, Canberra, Australia","author":"N Mehmood","year":"2014","unstructured":"Mehmood N, Hariz A, Templeton S, Voelcker NH. \u201cAn Innovative Sensing Technology for Chronic Wound Monitoring,\u201d in Australian Biomedical Engineering Conference, Canberra, Australia, 20\u2013 22. 2014."},{"key":"11_CR35","doi-asserted-by":"crossref","first-page":"23","DOI":"10.1016\/j.sbsr.2014.10.005","volume":"2","author":"N Mehmood","year":"2014","unstructured":"Mehmood N, Hariz A, Templeton S, Voelcker NH: Calibration of sensors for reliable radio telemetry in a prototype flexible wound monitoring device. Sensing Bio-Sensing Res 2014, 2: 23\u201330. 10.1016\/j.sbsr.2014.10.005","journal-title":"Sensing Bio-Sensing Res"},{"key":"11_CR36","doi-asserted-by":"crossref","first-page":"73","DOI":"10.1109\/RBME.2013.2295817","volume":"7","author":"M Ochoa","year":"2014","unstructured":"Ochoa M, Rahimi R, Ziaie B: \u201cFlexible sensors for chronic wound management\u201d. Biomed Eng, IEEE Rev 2014, 7: 73\u201386. 10.1109\/RBME.2013.2295817","journal-title":"Biomed Eng, IEEE Rev"},{"key":"11_CR37","unstructured":"Online datasheet Texas Instruments temperature sensor LM94021. 2013. Available: http:\/\/www.ti.com\/lit\/ds\/symlink\/lm94021.pdf., Online datasheet Texas Instruments temperature sensor LM94021. 2013. Available: . http:\/\/www.ti.com\/lit\/ds\/symlink\/lm94021.pdf"},{"key":"11_CR38","unstructured":"Online datasheet of RF transceiver ATMega128RFA1. 2013. Available: http:\/\/www.atmel.com\/devices\/ATMEGA128RFA1.aspx., Online datasheet of RF transceiver ATMega128RFA1. 2013. Available: . http:\/\/www.atmel.com\/devices\/ATMEGA128RFA1.aspx"},{"key":"11_CR39","unstructured":"Online datasheet of RF Balun 2450FB15L0001E by Johanson Technology. 2013. Available: http:\/\/www.johansontechnology.com\/datasheets\/balun-filter\/2450FB15L0001.pdf., Online datasheet of RF Balun 2450FB15L0001E by Johanson Technology. 2013. Available: . http:\/\/www.johansontechnology.com\/datasheets\/balun-filter\/2450FB15L0001.pdf"},{"key":"11_CR40","unstructured":"Online datasheet of 2.4GHz chip antenna model 2450AT43B100 by Johanson Technology. 2013. Available: http:\/\/www.johansontechnology.com\/datasheets\/antennas\/2450AT43B100.pdf., Online datasheet of 2.4GHz chip antenna model 2450AT43B100 by Johanson Technology. 2013. Available: . http:\/\/www.johansontechnology.com\/datasheets\/antennas\/2450AT43B100.pdf"},{"key":"11_CR41","unstructured":"Online datasheet of DS-G160128STBWW LCD module. 2013. Available: https:\/\/www.sparkfun.com\/datasheets\/LCD\/DS-G160128STBWW.pdf., Online datasheet of DS-G160128STBWW LCD module. 2013. Available: . https:\/\/www.sparkfun.com\/datasheets\/LCD\/DS-G160128STBWW.pdf"},{"key":"11_CR42","unstructured":"Online datasheet of Toshiba T6963C dot matrix LCD controller. 2013. Available: http:\/\/www.mikroe.com\/downloads\/get\/1910\/t6963c_spec.pdf., Online datasheet of Toshiba T6963C dot matrix LCD controller. 2013. Available: . http:\/\/www.mikroe.com\/downloads\/get\/1910\/t6963c_spec.pdf"},{"key":"11_CR43","doi-asserted-by":"crossref","first-page":"324","DOI":"10.1111\/j.1742-481X.2009.00621.x","volume":"6","author":"A Keller","year":"2009","unstructured":"Keller A, M\u00fcller ML, Calow T, Kern IK, Schumann H: Bandage pressure measurement and training: simple interventions to improve efficacy in compression bandaging. Int Wound J 2009, 6: 324. 10.1111\/j.1742-481X.2009.00621.x","journal-title":"Int Wound J"}],"container-title":["BioMedical Engineering OnLine"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s12938-015-0011-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1186\/s12938-015-0011-y\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s12938-015-0011-y","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,3,26]],"date-time":"2019-03-26T18:40:02Z","timestamp":1553625602000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.biomedical-engineering-online.com\/content\/14\/1\/17"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,3,1]]},"references-count":43,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2015,12]]}},"alternative-id":["11"],"URL":"https:\/\/doi.org\/10.1186\/s12938-015-0011-y","relation":{},"ISSN":["1475-925X"],"issn-type":[{"value":"1475-925X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2015,3,1]]},"article-number":"17"}}