{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,6,12]],"date-time":"2024-06-12T07:56:33Z","timestamp":1718178993975},"reference-count":25,"publisher":"Springer Science and Business Media LLC","issue":"1","content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BioMed Eng OnLine"],"published-print":{"date-parts":[[2016,12]]},"DOI":"10.1186\/s12938-016-0144-7","type":"journal-article","created":{"date-parts":[[2016,3,9]],"date-time":"2016-03-09T06:38:59Z","timestamp":1457505539000},"update-policy":"http:\/\/dx.doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":10,"title":["Monitoring of CRT-D devices during radiation therapy in vitro"],"prefix":"10.1186","volume":"15","author":[{"given":"Martin","family":"Augustynek","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"David","family":"Korpas","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Marek","family":"Penhaker","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jakub","family":"Cvek","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Andrea","family":"Binarova","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2016,3,9]]},"reference":[{"issue":"12","key":"144_CR1","doi-asserted-by":"crossref","first-page":"2153","DOI":"10.1016\/j.jacc.2005.09.019","volume":"46","author":"JJ Bax","year":"2005","unstructured":"Bax JJ, et al. Cardiac resynchronization therapy: part 1\u2013issues before device implantation. J Am Coll Cardiol. 2005;46(12):2153\u201367.","journal-title":"J Am Coll Cardiol"},{"issue":"6","key":"144_CR2","doi-asserted-by":"crossref","first-page":"474","DOI":"10.1016\/j.ctrv.2005.05.002","volume":"31","author":"S Sundar","year":"2005","unstructured":"Sundar S, Symonds RP, Deehan C. Radiotherapy to patients with artificial cardiac pacemakers. Cancer Treat Rev. 2005;31(6):474\u201386.","journal-title":"Cancer Treat Rev"},{"issue":"2","key":"144_CR3","doi-asserted-by":"crossref","first-page":"89","DOI":"10.1056\/NEJM199601113340206","volume":"334","author":"FM Kusumoto","year":"1996","unstructured":"Kusumoto FM, Goldschlager N. Cardiac pacing. N Engl J Med. 1996;334(2):89\u201397.","journal-title":"N Engl J Med"},{"issue":"5","key":"144_CR4","doi-asserted-by":"crossref","first-page":"863","DOI":"10.1046\/j.1460-9592.2001.00863.x","volume":"24","author":"H Ector","year":"2001","unstructured":"Ector H, et al. The World survey of cardiac pacing and implantable cardioverter defibrillators: calendar year 1997\u2013Europe. Pacing Clin Electrophysiol. 2001;24(5):863\u20138.","journal-title":"Pacing Clin Electrophysiol"},{"issue":"5","key":"144_CR5","doi-asserted-by":"crossref","first-page":"842","DOI":"10.1046\/j.1460-9592.2001.00842.x","volume":"24","author":"AD Bernstein","year":"2001","unstructured":"Bernstein AD, Parsonnet V. Survey of cardiac pacing and implanted defibrillator practice patterns in the United States in 1997. Pacing Clin Electrophysiol. 2001;24(5):842\u201355.","journal-title":"Pacing Clin Electrophysiol"},{"issue":"6","key":"144_CR6","doi-asserted-by":"crossref","first-page":"727","DOI":"10.1111\/j.1540-8159.2008.01077.x","volume":"31","author":"S Kapa","year":"2008","unstructured":"Kapa S, et al. Effects of scatter radiation on ICD and CRT function. Pacing Clin Electrophysiol. 2008;31(6):727\u201332.","journal-title":"Pacing Clin Electrophysiol"},{"issue":"1","key":"144_CR7","doi-asserted-by":"crossref","first-page":"85","DOI":"10.1118\/1.597259","volume":"21","author":"JR Marbach","year":"1994","unstructured":"Marbach JR, et al. Management of radiation oncology patients with implanted cardiac pacemakers: report of AAPM Task Group No. 34. American Association of Physicists in Medicine. Med Phys. 1994;21(1):85\u201390.","journal-title":"Med Phys"},{"issue":"841","key":"144_CR8","doi-asserted-by":"crossref","first-page":"4","DOI":"10.1259\/bjr.71.841.9534692","volume":"71","author":"A Last","year":"1998","unstructured":"Last A. Radiotherapy in patients with cardiac pacemakers. Br J Radiol. 1998;71(841):4\u201310.","journal-title":"Br J Radiol"},{"issue":"2","key":"144_CR9","doi-asserted-by":"crossref","first-page":"160","DOI":"10.1111\/j.1540-8159.1982.tb02208.x","volume":"5","author":"RV Calfee","year":"1982","unstructured":"Calfee RV. Therapeutic radiation and pacemakers. Pacing Clin Electrophysiol. 1982;5(2):160\u20131.","journal-title":"Pacing Clin Electrophysiol"},{"issue":"1","key":"144_CR10","doi-asserted-by":"crossref","first-page":"282","DOI":"10.1016\/j.ijrobp.2005.04.047","volume":"63","author":"CW Hurkmans","year":"2005","unstructured":"Hurkmans CW, et al. Influence of radiotherapy on the latest generation of implantable cardioverter-defibrillators. Int J Radiat Oncol Biol Phys. 2005;63(1):282\u20139.","journal-title":"Int J Radiat Oncol Biol Phys"},{"issue":"12","key":"144_CR11","doi-asserted-by":"crossref","first-page":"2143","DOI":"10.1111\/j.1540-8159.1991.tb06485.x","volume":"14","author":"F Rodriguez","year":"1991","unstructured":"Rodriguez F, et al. Radiation-induced effects in multiprogrammable pacemakers and implantable defibrillators. Pacing Clin Electrophysiol. 1991;14(12):2143\u201353.","journal-title":"Pacing Clin Electrophysiol"},{"issue":"2","key":"144_CR12","doi-asserted-by":"crossref","first-page":"146","DOI":"10.1111\/j.1540-8159.1982.tb02205.x","volume":"5","author":"R Adamec","year":"1982","unstructured":"Adamec R, et al. Damaging effect of therapeutic radiation on programmable pacemakers. Pacing Clin Electrophysiol. 1982;5(2):146\u201350.","journal-title":"Pacing Clin Electrophysiol"},{"issue":"1","key":"144_CR13","doi-asserted-by":"crossref","first-page":"81","DOI":"10.1016\/S0167-8140(85)80011-6","volume":"3","author":"JL Venselaar","year":"1985","unstructured":"Venselaar JL. The effects of ionizing radiation on eight cardiac pacemakers and the influence of electromagnetic interference from two linear accelerators. Radiother Oncol. 1985;3(1):81\u20137.","journal-title":"Radiother Oncol"},{"issue":"3 Pt 1","key":"144_CR14","doi-asserted-by":"crossref","first-page":"538","DOI":"10.1111\/j.1540-8159.1987.tb04517.x","volume":"10","author":"JL Venselaar","year":"1987","unstructured":"Venselaar JL, Van Kerkoerle HL, Vet AJ. Radiation damage to pacemakers from radiotherapy. Pacing Clin Electrophysiol. 1987;10(3 Pt 1):538\u201342.","journal-title":"Pacing Clin Electrophysiol"},{"issue":"2","key":"144_CR15","first-page":"153","volume":"166","author":"J Salmi","year":"1990","unstructured":"Salmi J, et al. The influence of electromagnetic interference and ionizing radiation on cardiac pacemakers. Strahlenther Onkol. 1990;166(2):153\u20136.","journal-title":"Strahlenther Onkol"},{"issue":"1","key":"144_CR16","doi-asserted-by":"crossref","first-page":"105","DOI":"10.1111\/j.1440-1673.1993.tb00027.x","volume":"37","author":"SL Ngu","year":"1993","unstructured":"Ngu SL, et al. Pacemaker function during irradiation: in vivo and in vitro effect. Australas Radiol. 1993;37(1):105\u20137.","journal-title":"Australas Radiol"},{"issue":"10","key":"144_CR17","first-page":"330","volume":"14","author":"G Uiterwaal","year":"2006","unstructured":"Uiterwaal G, et al. Interference detection in implantable defibrillators induced by therapeutic radiation therapy. Netherlands Heart J. 2006;14(10):330.","journal-title":"Netherlands Heart J"},{"issue":"12","key":"144_CR18","doi-asserted-by":"crossref","first-page":"1964","DOI":"10.1016\/j.hrthm.2012.08.018","volume":"9","author":"A Makkar","year":"2012","unstructured":"Makkar A, et al. Effect of radiation therapy on permanent pacemaker and implantable cardioverter-defibrillator function. Heart Rhythm. 2012;9(12):1964\u20138.","journal-title":"Heart Rhythm"},{"issue":"4","key":"144_CR19","doi-asserted-by":"crossref","first-page":"612","DOI":"10.1093\/europace\/eut249","volume":"16","author":"T Zaremba","year":"2014","unstructured":"Zaremba T, et al. The effect of radiotherapy beam energy on modern cardiac devices: an in vitro study. Europace. 2014;16(4):612\u20136.","journal-title":"Europace"},{"issue":"3","key":"144_CR20","doi-asserted-by":"crossref","first-page":"840","DOI":"10.1016\/j.ijrobp.2012.05.043","volume":"85","author":"H Hashii","year":"2013","unstructured":"Hashii H, et al. Comparison of the effects of high-energy photon beam irradiation (10 and 18\u00a0MV) on 2 types of implantable cardioverter-defibrillators. Int J Radiat Oncol Biol Phys. 2013;85(3):840\u20135.","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"144_CR21","unstructured":"Guidant Corporation Cardiac Rhythm Management Technical Services. Impact of therapeutic radiation and guidant ICD\/CRTD\/CRT-P\/pacing systems. St. Paul MN, Guidant Corporation, 2004, Revision. pp. 1\u20136."},{"issue":"5","key":"144_CR22","doi-asserted-by":"crossref","first-page":"1525","DOI":"10.1016\/j.ijrobp.2008.06.1903","volume":"73","author":"DY Gelblum","year":"2009","unstructured":"Gelblum DY, Amols H. Implanted cardiac defibrillator care in radiation oncology patient population. Int J Radiat Oncol Biol Phys. 2009;73(5):1525\u201331.","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"144_CR23","unstructured":"Therapeutic radiation and implantable device Systems. 2012, Boston Scientific."},{"key":"144_CR24","unstructured":"Kobayashi H, et al. Soft errors in SRAM devices induced by high energy neutrons, thermal neutrons and alpha particles. in Electron Devices Meeting, 2002. IEDM\u201902. International. 2002. IEEE."},{"issue":"3","key":"144_CR25","doi-asserted-by":"crossref","first-page":"449","DOI":"10.1109\/TDMR.2005.858342","volume":"5","author":"JD Wilkinson","year":"2005","unstructured":"Wilkinson JD, et al. Cancer-radiotherapy equipment as a cause of soft errors in electronic equipment. Device and Materials Reliability, IEEE Transactions on. 2005;5(3):449\u201351.","journal-title":"Device and Materials Reliability, IEEE Transactions on"}],"container-title":["BioMedical Engineering OnLine"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s12938-016-0144-7","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2017,6,24]],"date-time":"2017-06-24T03:58:24Z","timestamp":1498276704000},"score":1,"resource":{"primary":{"URL":"http:\/\/www.biomedical-engineering-online.com\/content\/15\/1\/29"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,3,9]]},"references-count":25,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2016,12]]}},"alternative-id":["144"],"URL":"https:\/\/doi.org\/10.1186\/s12938-016-0144-7","relation":{},"ISSN":["1475-925X"],"issn-type":[{"value":"1475-925X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2016,3,9]]},"article-number":"29"}}