{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,4,10]],"date-time":"2025-04-10T20:28:52Z","timestamp":1744316932269,"version":"3.37.3"},"reference-count":33,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2018,10,23]],"date-time":"2018-10-23T00:00:00Z","timestamp":1540252800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100000024","name":"Canadian Institutes of Health Research","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100000024","id-type":"DOI","asserted-by":"crossref"}]},{"name":"Canada Research Chair (CRC) program"},{"DOI":"10.13039\/501100000038","name":"Natural Sciences and Engineering Research Council of Canada","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100000038","id-type":"DOI","asserted-by":"crossref"}]},{"name":"Canada Foundation for Innovation Leader\u2019s Opportunity Fund","award":["CFI IOF 2013-26913"],"award-info":[{"award-number":["CFI IOF 2013-26913"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BioMed Eng OnLine"],"published-print":{"date-parts":[[2018,12]]},"DOI":"10.1186\/s12938-018-0593-2","type":"journal-article","created":{"date-parts":[[2018,10,23]],"date-time":"2018-10-23T15:15:19Z","timestamp":1540307719000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":12,"title":["Regressing grasping using force myography: an exploratory study"],"prefix":"10.1186","volume":"17","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-9683-0388","authenticated-orcid":false,"given":"Rana","family":"Sadeghi Chegani","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Carlo","family":"Menon","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2018,10,23]]},"reference":[{"issue":"3","key":"593_CR1","doi-asserted-by":"publisher","first-page":"422","DOI":"10.1016\/j.apmr.2007.11.005","volume":"89","author":"K Ziegler-Graham","year":"2008","unstructured":"Ziegler-Graham K, MacKenzie EJ, Ephraim PL, Travison TG, Brookmeyer R. Estimating the prevalence of limb loss in the united states: 2005 to 2050. Arch Phys Med Rehabil. 2008;89(3):422\u20139.","journal-title":"Arch Phys Med Rehabil"},{"issue":"5","key":"593_CR2","doi-asserted-by":"crossref","first-page":"534","DOI":"10.1097\/SAP.0b013e3181bffcaf","volume":"64","author":"N Gavrilova","year":"2010","unstructured":"Gavrilova N, Harijan A, Schiro S, Hultman CS, Lee C. Patterns of finger amputation and replantation in the setting of a rapidly growing immigrant population. Ann Plast Surg. 2010;64(5):534\u20136.","journal-title":"Ann Plast Surg"},{"key":"593_CR3","doi-asserted-by":"publisher","first-page":"32","DOI":"10.1109\/RBME.2016.2523799","volume":"9","author":"I Imbinto","year":"2016","unstructured":"Imbinto I, Peccia C, Controzzi M, Cutti AG, Davalli A, Sacchetti R, Cipriani C. Treatment of the partial hand amputation: an engineering perspective. IEEE Rev Biomed Eng. 2016;9:32\u201348.","journal-title":"IEEE Rev Biomed Eng"},{"issue":"6","key":"593_CR4","doi-asserted-by":"publisher","first-page":"857","DOI":"10.1097\/PRS.0000000000004368","volume":"141","author":"PL Reavey","year":"2018","unstructured":"Reavey PL, Stranix JT, Muresan H, Soares M, Thanik V. Disappearing digits: analysis of national trends in amputation and replantation in the United States. Plast Reconstr Surg. 2018;141(6):857\u201367.","journal-title":"Plast Reconstr Surg"},{"key":"593_CR5","doi-asserted-by":"crossref","unstructured":"Adewuyi AA, Hargrove LJ, Kuiken TA. Towards improved partial-hand prostheses: the effect of wrist kinematics on pattern-recognition-based control. In: 2013 6th international IEEE\/EMBS conference on neural engineering (NER). New York: IEEE; 2013. p. 1489\u201392.","DOI":"10.1109\/NER.2013.6696227"},{"key":"593_CR6","doi-asserted-by":"crossref","first-page":"69","DOI":"10.1097\/JPO.0000000000000180","volume":"30","author":"LR Whelan","year":"2018","unstructured":"Whelan LR, Farley J. Functional outcomes with externally powered partial hand prostheses. J Prosthet Orthot. 2018;30:69\u201373.","journal-title":"J Prosthet Orthot"},{"key":"593_CR7","doi-asserted-by":"crossref","unstructured":"Krasoulis A, Member S, Vijayakumar S. Evaluation of regression methods for the continuous decoding of finger movement from surface EMG and accelerometry. In: 7th annual international IEEE EMBS conference on neural engineering, Montpellier. 2015. p. 631\u20134.","DOI":"10.1109\/NER.2015.7146702"},{"key":"593_CR8","doi-asserted-by":"crossref","unstructured":"Smith RJ, Tenore F, Huberdeau D, Etienne-Cummings R, Thakor NV. Continuous decoding of finger position from surface EMG signals for the control of powered prostheses. In: Engineering in Medicine and Biology Society, 2008. EMBS 2008. 30th annual international conference of the IEEE; New York: IEEE; 2008. p. 197\u2013200.","DOI":"10.1109\/IEMBS.2008.4649124"},{"key":"593_CR9","doi-asserted-by":"crossref","unstructured":"Ngeo J, Tamei T, Shibata T. Continuous estimation of finger joint angles using muscle activation inputs from surface EMG signals. In: Engineering in Medicine and Biology Society (EMBC), 2012 annual international conference of the IEEE. New York: IEEE; 2012. p. 2756\u20139.","DOI":"10.1109\/EMBC.2012.6346535"},{"key":"593_CR10","doi-asserted-by":"publisher","first-page":"493","DOI":"10.1007\/978-3-642-40852-6_50","volume-title":"Intelligent Robotics and Applications","author":"Lizhi Pan","year":"2013","unstructured":"Pan L, Sheng X, Zhang D, Zhu X. Simultaneous and proportional estimation of finger joint angles from surface EMG signals during mirrored bilateral movements. In: International conference on intelligent robotics and applications. Berlin: Springer; 2013. p. 493\u20139."},{"key":"593_CR11","doi-asserted-by":"publisher","first-page":"265","DOI":"10.1016\/j.bspc.2014.08.004","volume":"14","author":"L Pan","year":"2014","unstructured":"Pan L, Zhang D, Liu J, Sheng X, Zhu X. Continuous estimation of finger joint angles under different static wrist motions from surface EMG signals. Biomed Signal Process Control. 2014;14:265\u201371.","journal-title":"Biomed Signal Process Control"},{"key":"593_CR12","doi-asserted-by":"publisher","first-page":"22","DOI":"10.3389\/fnbot.2014.00022","volume":"8","author":"C Castellini","year":"2014","unstructured":"Castellini C, Artemiadis P, Wininger M, Ajoudani A, Alimusaj M, Bicchi A, Caputo B, Craelius W, Dosen S, Englehart K. Proceedings of the first workshop on peripheral machine interfaces: going beyond traditional surface electromyography. Front Neurorobotics. 2014;8:22.","journal-title":"Front Neurorobotics"},{"issue":"6","key":"593_CR13","doi-asserted-by":"publisher","first-page":"883","DOI":"10.1682\/JRRD.2007.11.0187","volume":"45","author":"M Wininger","year":"2008","unstructured":"Wininger M, Kim N-H, Craelius W. Pressure signature of forearm as predictor of grip force. J Rehabil Res Dev. 2008;45(6):883.","journal-title":"J Rehabil Res Dev"},{"key":"593_CR14","doi-asserted-by":"crossref","unstructured":"Xiao ZG, Menon C. Counting grasping action using force myography: an exploratory study with healthy individuals. JMIR Rehabil Assistive Technol. 2017;4(1)","DOI":"10.2196\/rehab.6901"},{"issue":"1","key":"593_CR15","doi-asserted-by":"publisher","first-page":"39","DOI":"10.1016\/S1672-6529(11)60095-4","volume":"9","author":"N Li","year":"2012","unstructured":"Li N, Yang D, Jiang L, Liu H, Cai H. Combined use of FSR sensor array and SVM classifier for finger motion recognition based on pressure distribution map. J Bionic Eng. 2012;9(1):39\u201347.","journal-title":"J Bionic Eng"},{"key":"593_CR16","doi-asserted-by":"crossref","unstructured":"Castellini C, Ravindra V. A wearable low-cost device based upon force-sensing resistors to detect single-finger forces. In: 2014 5th IEEE RAS & EMBS international conference on biomedical robotics and biomechatronics. New York: IEEE; 2014. p. 199\u2013203.","DOI":"10.1109\/BIOROB.2014.6913776"},{"issue":"4","key":"593_CR17","doi-asserted-by":"publisher","first-page":"443","DOI":"10.1682\/JRRD.2015.03.0041","volume":"53","author":"Ashkan Radmand","year":"2016","unstructured":"Radmand A, Scheme E, Englehart K. High-density force myography: a possible alternative for upper-limb prosthetic control. J Rehabil Res Dev. 2016;53(4).","journal-title":"Journal of Rehabilitation Research and Development"},{"key":"593_CR18","doi-asserted-by":"publisher","first-page":"63","DOI":"10.1016\/j.medengphy.2017.01.015","volume":"41","author":"X Jiang","year":"2017","unstructured":"Jiang X, Merhi L-K, Xiao ZG, Menon C. Exploration of force myography and surface electromyography in hand gesture classification. Med Eng Phys. 2017;41:63\u201373.","journal-title":"Med Eng Phys"},{"key":"593_CR19","doi-asserted-by":"publisher","first-page":"17","DOI":"10.3389\/fnbot.2016.00017","volume":"10","author":"M Connan","year":"2016","unstructured":"Connan M, Ruiz Ram\u00edrez E, Vodermayer B, Castellini C. Assessment of a wearable force-and electromyography device and comparison of the related signals for myocontrol. Front Neurorobotics. 2016;10:17.","journal-title":"Front Neurorobotics"},{"key":"593_CR20","doi-asserted-by":"publisher","first-page":"18","DOI":"10.3389\/fbioe.2016.00018","volume":"4","author":"E Cho","year":"2016","unstructured":"Cho E, Chen R, Merhi L-K, Xiao Z, Pousett B, Menon C, et al. Force myography to control robotic upper extremity prostheses: a feasibility study. Front Bioeng Biotechnol. 2016;4:18.","journal-title":"Front Bioeng Biotechnol"},{"issue":"4","key":"593_CR21","doi-asserted-by":"publisher","first-page":"102","DOI":"10.1109\/MRA.2017.2747899","volume":"24","author":"C Ahmadizadeh","year":"2017","unstructured":"Ahmadizadeh C, Merhi L-K, Pousett B, Sangha S, Menon C. Toward intuitive prosthetic control: solving common issues using force myography, surface electromyography, and pattern recognition in a pilot case study. IEEE Robot Autom Mag. 2017;24(4):102\u201311.","journal-title":"IEEE Robot Autom Mag"},{"issue":"3","key":"593_CR22","doi-asserted-by":"publisher","first-page":"277","DOI":"10.1017\/S0263574704001298","volume":"23","author":"SL Phillips","year":"2005","unstructured":"Phillips SL, Craelius W. Residual kinetic imaging: a versatile interface for prosthetic control. Robotica. 2005;23(3):277\u201382.","journal-title":"Robotica"},{"issue":"4","key":"593_CR23","doi-asserted-by":"publisher","first-page":"594","DOI":"10.1007\/s40846-016-0151-y","volume":"36","author":"A Kadkhodayan","year":"2016","unstructured":"Kadkhodayan A, Jiang X, Menon C. Continuous prediction of finger movements using force myography. J Med Biol Eng. 2016;36(4):594\u2013604. https:\/\/doi.org\/10.1007\/s40846-016-0151-y .","journal-title":"J Med Biol Eng"},{"issue":"1","key":"593_CR24","doi-asserted-by":"publisher","first-page":"5","DOI":"10.1023\/A:1010933404324","volume":"45","author":"L Breiman","year":"2001","unstructured":"Breiman L. Random forests. Mach Learn. 2001;45(1):5\u201332.","journal-title":"Mach Learn"},{"issue":"3","key":"593_CR25","first-page":"18","volume":"2","author":"A Liaw","year":"2002","unstructured":"Liaw A, Wiener M. Classification and regression by randomforest. R News. 2002;2(3):18\u201322.","journal-title":"R News"},{"key":"593_CR26","unstructured":"Interlink Electronics: FSR\u00ae 400 Series datasheet. Interlink Electronics"},{"key":"593_CR27","unstructured":"Interlink Electronics: FSR\u00ae Integration Guide. Interlink Electronics. Rev. C"},{"issue":"3","key":"593_CR28","doi-asserted-by":"publisher","first-page":"269","DOI":"10.1109\/70.34763","volume":"5","author":"MR Cutkosky","year":"1989","unstructured":"Cutkosky MR. On grasp choice, grasp models, and the design of hands for manufacturing tasks. IEEE Trans Robot Autom. 1989;5(3):269\u201379.","journal-title":"IEEE Trans Robot Autom"},{"issue":"4","key":"593_CR29","doi-asserted-by":"publisher","first-page":"418","DOI":"10.1109\/TMECH.2007.901936","volume":"12","author":"L Zollo","year":"2007","unstructured":"Zollo L, Roccella S, Guglielmelli E, Carrozza MC, Dario P. Biomechatronic design and control of an anthropomorphic artificial hand for prosthetic and robotic applications. IEEE\/ASME Trans Mechatron. 2007;12(4):418\u201329.","journal-title":"IEEE\/ASME Trans Mechatron"},{"issue":"3","key":"593_CR30","doi-asserted-by":"publisher","first-page":"107","DOI":"10.1089\/soro.2015.0009","volume":"2","author":"M Manti","year":"2015","unstructured":"Manti M, Hassan T, Passetti G, D\u2019Elia N, Laschi C, Cianchetti M. A bioinspired soft robotic gripper for adaptable and effective grasping. Soft Robot. 2015;2(3):107\u201316. https:\/\/doi.org\/10.1089\/soro.2015.0009 .","journal-title":"Soft Robot"},{"key":"593_CR31","doi-asserted-by":"publisher","unstructured":"Jiang H, Wachs JP, Duerstock BS. Integrated vision-based robotic arm interface for operators with upper limb mobility impairments. In: 2013 IEEE 13th international conference on rehabilitation robotics (ICORR), Seattle. 2013. p. 1\u20136. https:\/\/doi.org\/10.1109\/ICORR.2013.6650447","DOI":"10.1109\/ICORR.2013.6650447"},{"issue":"2","key":"593_CR32","doi-asserted-by":"publisher","first-page":"284","DOI":"10.1016\/S1672-6529(16)60398-0","volume":"14","author":"ZG Xiao","year":"2017","unstructured":"Xiao ZG, Menon C. Performance of forearm FMG and SEMG for estimating elbow, forearm and wrist positions. J Bionic Eng. 2017;14(2):284\u201395.","journal-title":"J Bionic Eng"},{"issue":"3","key":"593_CR33","doi-asserted-by":"publisher","first-page":"553","DOI":"10.1037\/0033-2909.113.3.553","volume":"113","author":"JL Rogers","year":"1993","unstructured":"Rogers JL, Howard KI, Vessey JT. Using significance tests to evaluate equivalence between two experimental groups. Psychol Bull. 1993;113(3):553.","journal-title":"Psychol Bull"}],"container-title":["BioMedical Engineering OnLine"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s12938-018-0593-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1186\/s12938-018-0593-2\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s12938-018-0593-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,9,4]],"date-time":"2022-09-04T13:59:48Z","timestamp":1662299988000},"score":1,"resource":{"primary":{"URL":"https:\/\/biomedical-engineering-online.biomedcentral.com\/articles\/10.1186\/s12938-018-0593-2"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,10,23]]},"references-count":33,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2018,12]]}},"alternative-id":["593"],"URL":"https:\/\/doi.org\/10.1186\/s12938-018-0593-2","relation":{},"ISSN":["1475-925X"],"issn-type":[{"type":"electronic","value":"1475-925X"}],"subject":[],"published":{"date-parts":[[2018,10,23]]},"assertion":[{"value":"22 June 2018","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"15 October 2018","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"23 October 2018","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}}],"article-number":"159"}}