{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,9]],"date-time":"2026-01-09T23:20:10Z","timestamp":1768000810605,"version":"3.49.0"},"reference-count":39,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2019,7,24]],"date-time":"2019-07-24T00:00:00Z","timestamp":1563926400000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2019,7,24]],"date-time":"2019-07-24T00:00:00Z","timestamp":1563926400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100006769","name":"Russian Science Foundation","doi-asserted-by":"publisher","award":["16-15-10327"],"award-info":[{"award-number":["16-15-10327"]}],"id":[{"id":"10.13039\/501100006769","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BioMed Eng OnLine"],"published-print":{"date-parts":[[2019,12]]},"DOI":"10.1186\/s12938-019-0699-1","type":"journal-article","created":{"date-parts":[[2019,7,24]],"date-time":"2019-07-24T15:02:45Z","timestamp":1563980565000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":14,"title":["Evaluation of flow changes after telescopic stenting of a giant fusiform aneurysm of the vertebrobasilar junction"],"prefix":"10.1186","volume":"18","author":[{"given":"Sergey","family":"Sindeev","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jan Stephan","family":"Kirschke","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sascha","family":"Prothmann","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sergey","family":"Frolov","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dieter","family":"Liepsch","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Philipp","family":"Berg","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Claus","family":"Zimmer","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2198-9925","authenticated-orcid":false,"given":"Benjamin","family":"Friedrich","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2019,7,24]]},"reference":[{"key":"699_CR1","first-page":"13","volume":"1","author":"CJ Griessenauer","year":"2018","unstructured":"Griessenauer CJ, Ogilvy CS, Adeeb N, Dmytriw AA, Foreman PM, Shallwani H, et al. Pipeline embolization of posterior circulation aneurysms: a multicenter study of 131 aneurysms. J Neurosurg. 2018;1:13.","journal-title":"J Neurosurg."},{"key":"699_CR2","doi-asserted-by":"publisher","first-page":"259","DOI":"10.1007\/s00701-004-0473-3","volume":"147","author":"G Clarke","year":"2005","unstructured":"Clarke G, Mendelow AD, Mitchell P. Predicting the risk of rupture of intracranial aneurysms based on anatomical location. Acta Neurochir (Wien). 2005;147:259\u201363 (discussion 263).","journal-title":"Acta Neurochir (Wien)."},{"key":"699_CR3","doi-asserted-by":"publisher","first-page":"189","DOI":"10.4103\/sni.sni_133_18","volume":"9","author":"EA Barletta","year":"2018","unstructured":"Barletta EA, Ricci RL, Silva RDG, Gaspar RHML, Ara\u00fajo JFM, Neves MWF, et al. Fusiform aneurysms: a review from its pathogenesis to treatment options. Surg Neurol Int. 2018;9:189.","journal-title":"Surg Neurol Int."},{"key":"699_CR4","doi-asserted-by":"publisher","first-page":"790","DOI":"10.1093\/neuros\/nyx561","volume":"83","author":"AN Wallace","year":"2018","unstructured":"Wallace AN, Grossberg JA, Almandoz JED, Kamran M, Roy AK, Kayan Y, et al. Endovascular treatment of posterior cerebral artery aneurysms with flow diversion: case series and systematic review. Neurosurgery. 2018;83:790\u20139.","journal-title":"Neurosurgery."},{"key":"699_CR5","doi-asserted-by":"publisher","first-page":"391","DOI":"10.1007\/s00234-016-1649-2","volume":"58","author":"C-B Wang","year":"2016","unstructured":"Wang C-B, Shi W-W, Zhang G-X, Lu H-C, Ma J. Flow diverter treatment of posterior circulation aneurysms. A meta-analysis. Neuroradiology. 2016;58:391\u2013400.","journal-title":"Neuroradiology."},{"key":"699_CR6","doi-asserted-by":"publisher","first-page":"855","DOI":"10.3171\/jns.2007.106.5.855","volume":"106","author":"BA Coert","year":"2007","unstructured":"Coert BA, Chang SD, Do HM, Marks MP, Steinberg GK. Surgical and endovascular management of symptomatic posterior circulation fusiform aneurysms. J Neurosurg. 2007;106:855\u201365.","journal-title":"J Neurosurg"},{"key":"699_CR7","doi-asserted-by":"publisher","first-page":"E14","DOI":"10.3171\/2017.3.FOCUS1748","volume":"42","author":"AJ Awad","year":"2017","unstructured":"Awad AJ, Mascitelli JR, Haroun RR, De Leacy RA, Fifi JT, Mocco J. Endovascular management of fusiform aneurysms in the posterior circulation: the era of flow diversion. Neurosurg Focus. 2017;42:E14.","journal-title":"Neurosurg Focus"},{"key":"699_CR8","doi-asserted-by":"publisher","first-page":"641","DOI":"10.1136\/neurintsurg-2014-011340","volume":"7","author":"FC Albuquerque","year":"2015","unstructured":"Albuquerque FC, Park MS, Abla AA, Crowley RW, Ducruet AF, McDougall CG. A reappraisal of the Pipeline embolization device for the treatment of posterior circulation aneurysms. J Neurointerv Surg. 2015;7:641\u20135.","journal-title":"J Neurointerv Surg."},{"key":"699_CR9","doi-asserted-by":"publisher","first-page":"883","DOI":"10.1227\/NEU.0b013e31828ba984","volume":"72","author":"N Chalouhi","year":"2013","unstructured":"Chalouhi N, Tjoumakaris S, Dumont AS, Gonzalez LF, Randazzo C, Starke RM, et al. Treatment of posterior circulation aneurysms with the pipeline embolization device. Neurosurgery. 2013;72:883\u20139.","journal-title":"Neurosurgery."},{"key":"699_CR10","doi-asserted-by":"publisher","first-page":"111","DOI":"10.3171\/2015.6.JNS1565","volume":"125","author":"SK Natarajan","year":"2016","unstructured":"Natarajan SK, Lin N, Sonig A, Rai AT, Carpenter JS, Levy EI, et al. The safety of Pipeline flow diversion in fusiform vertebrobasilar aneurysms: a consecutive case series with longer-term follow-up from a single US center. J Neurosurg. 2016;125:111\u20139.","journal-title":"J Neurosurg"},{"key":"699_CR11","doi-asserted-by":"publisher","first-page":"66","DOI":"10.1177\/1971400915621321","volume":"29","author":"X Lv","year":"2016","unstructured":"Lv X, Yang H, Liu P, Li Y. Flow-diverter devices in the treatment of intracranial aneurysms: a meta-analysis and systematic review. Neuroradiol J. 2016;29:66\u201371.","journal-title":"Neuroradiol J."},{"key":"699_CR12","doi-asserted-by":"publisher","first-page":"2346","DOI":"10.1161\/STROKEAHA.106.479576","volume":"38","author":"DF Kallmes","year":"2007","unstructured":"Kallmes DF, Ding YH, Dai D, Kadirvel R, Lewis DA, Cloft HJ. A new endoluminal, flow-disrupting device for treatment of saccular aneurysms. Stroke. 2007;38:2346\u201352.","journal-title":"Stroke"},{"key":"699_CR13","doi-asserted-by":"publisher","first-page":"300","DOI":"10.1177\/1591019915583119","volume":"21","author":"A Mpotsaris","year":"2015","unstructured":"Mpotsaris A, Skalej M, Beuing O, Eckert B, Behme D, Weber W. Long-term occlusion results with SILK flow diversion in 28 aneurysms: do recanalizations occur during follow-up? Interv Neuroradiol. 2015;21:300\u201310.","journal-title":"Interv Neuroradiol."},{"key":"699_CR14","doi-asserted-by":"publisher","first-page":"365","DOI":"10.1177\/1971400915602803","volume":"28","author":"F Briganti","year":"2015","unstructured":"Briganti F, Leone G, Marseglia M, Mariniello G, Caranci F, Brunetti A, et al. Endovascular treatment of cerebral aneurysms using flow-diverter devices: a systematic review. Neuroradiol J. 2015;28:365\u201375.","journal-title":"Neuroradiol J."},{"key":"699_CR15","doi-asserted-by":"publisher","first-page":"E1","DOI":"10.3174\/ajnr.A2613","volume":"34","author":"JJ Schneiders","year":"2013","unstructured":"Schneiders JJ, VanBavel E, Majoie CB, Ferns SP, van den Berg R. A flow-diverting stent is not a pressure-diverting stent. AJNR Am J Neuroradiol. 2013;34:E1\u20134.","journal-title":"AJNR Am J Neuroradiol"},{"key":"699_CR16","doi-asserted-by":"publisher","first-page":"202","DOI":"10.1016\/j.wneu.2017.07.157","volume":"107","author":"W Li","year":"2017","unstructured":"Li W, Liu J, Zhang Y, Wang K, Tian Z, Zhang Q, et al. Flow diversion and outcomes of vertebral fusiform aneurysms after stent-only treatment: a hemodynamic study. World Neurosurg. 2017;107:202\u201310.","journal-title":"World Neurosurg."},{"key":"699_CR17","doi-asserted-by":"publisher","first-page":"493","DOI":"10.1136\/neurintsurg-2017-013312","volume":"10","author":"S Kiyofuji","year":"2017","unstructured":"Kiyofuji S, Graffeo CS, Perry A, Murad MH, Flemming KD, Lanzino G, et al. Meta-analysis of treatment outcomes of posterior circulation non-saccular aneurysms by flow diverters. J Neurointerv Surg. 2017;10:493\u20139.","journal-title":"J Neurointerv Surg."},{"key":"699_CR18","doi-asserted-by":"publisher","first-page":"E17","DOI":"10.3171\/2017.3.FOCUS16450","volume":"42","author":"G Zhou","year":"2017","unstructured":"Zhou G, Su M, Yin Y-L, Li M-H. Complications associated with the use of flow-diverting devices for cerebral aneurysms: a systematic review and meta-analysis. Neurosurg Focus. 2017;42:E17.","journal-title":"Neurosurg Focus"},{"key":"699_CR19","doi-asserted-by":"publisher","first-page":"1097","DOI":"10.1007\/s11517-008-0420-1","volume":"46","author":"L Antiga","year":"2008","unstructured":"Antiga L, Piccinelli M, Botti L, Ene-Iordache B, Remuzzi A, Steinman DA. An image-based modeling framework for patient-specific computational hemodynamics. Med Biol Eng Comput. 2008;46:1097\u2013112.","journal-title":"Med Biol Eng Comput."},{"key":"699_CR20","doi-asserted-by":"publisher","first-page":"371","DOI":"10.1016\/B978-0-12-811018-8.00014-X","volume-title":"Computing and visualization for intravascular imaging and computer-assisted stenting","author":"P Berg","year":"2017","unstructured":"Berg P, Dar\u00f3czy L, Janiga G. Virtual stenting for intracranial aneurysms. Computing and visualization for intravascular imaging and computer-assisted stenting. New York: Elsevier; 2017. p. 371\u2013411."},{"key":"699_CR21","doi-asserted-by":"publisher","first-page":"7","DOI":"10.1016\/j.jbiomech.2012.08.047","volume":"46","author":"G Janiga","year":"2013","unstructured":"Janiga G, R\u00f6ssl C, Skalej M, Th\u00e9venin D. Realistic virtual intracranial stenting and computational fluid dynamics for treatment analysis. J Biomech. 2013;46:7\u201312.","journal-title":"J Biomech"},{"key":"699_CR22","doi-asserted-by":"publisher","first-page":"4","DOI":"10.1016\/j.jbiomech.2015.10.047","volume":"49","author":"P Berg","year":"2016","unstructured":"Berg P, Iosif C, Ponsonnard S, Yardin C, Janiga G, Mounayer C. Endothelialization of over- and undersized flow-diverter stents at covered vessel side branches: an in vivo and in silico study. J Biomech. 2016;49:4\u201312.","journal-title":"J Biomech"},{"key":"699_CR23","doi-asserted-by":"publisher","first-page":"648","DOI":"10.1038\/jcbfm.2014.241","volume":"35","author":"L Zarrinkoob","year":"2015","unstructured":"Zarrinkoob L, Ambarki K, W\u00e5hlin A, Birgander R, Eklund A, Malm J. Blood flow distribution in cerebral arteries. J Cereb Blood Flow Metab. 2015;35:648\u201354.","journal-title":"J Cereb Blood Flow Metab"},{"key":"699_CR24","doi-asserted-by":"publisher","first-page":"303","DOI":"10.1515\/bmt-2012-0119","volume":"58","author":"G Janiga","year":"2013","unstructured":"Janiga G, Berg P, Beuing O, Neugebauer M, Gasteiger R, Preim B, et al. Recommendations for accurate numerical blood flow simulations of stented intracranial aneurysms. Biomed Technol (Berl). 2013;58:303\u201314.","journal-title":"Biomed Technol (Berl)."},{"key":"699_CR25","doi-asserted-by":"publisher","first-page":"H1916","DOI":"10.1152\/ajpheart.00897.2003","volume":"286","author":"HA Himburg","year":"2004","unstructured":"Himburg HA, Grzybowski DM, Hazel AL, LaMack JA, Li X-M, Friedman MH. Spatial comparison between wall shear stress measures and porcine arterial endothelial permeability. Am J Physiol Heart Circ Physiol. 2004;286:H1916\u201322.","journal-title":"Am J Physiol Heart Circ Physiol."},{"key":"699_CR26","doi-asserted-by":"publisher","first-page":"061013","DOI":"10.1115\/1.3127252","volume":"131","author":"S-W Lee","year":"2009","unstructured":"Lee S-W, Antiga L, Steinman DA. Correlations among indicators of disturbed flow at the normal carotid bifurcation. J Biomech Eng. 2009;131:061013.","journal-title":"J Biomech Eng"},{"key":"699_CR27","doi-asserted-by":"publisher","first-page":"595","DOI":"10.1093\/neuros\/nyw123","volume":"81","author":"JM Pumar","year":"2017","unstructured":"Pumar JM, Banguero A, Cuellar H, Guimaraens L, Masso J, Miralbes S, et al. Treatment of intracranial aneurysms with the SILK embolization device in a multicenter study. A retrospective data analysis. Neurosurgery. 2017;81:595\u2013601.","journal-title":"Neurosurgery."},{"key":"699_CR28","doi-asserted-by":"publisher","first-page":"252","DOI":"10.1016\/j.wneu.2015.09.088","volume":"85","author":"G Zhou","year":"2016","unstructured":"Zhou G, Su M, Zhu Y-Q, Li M-H. Efficacy of flow-diverting devices for cerebral aneurysms: a systematic review and meta-analysis. World Neurosurg. 2016;85:252\u201362.","journal-title":"World Neurosurg."},{"key":"699_CR29","doi-asserted-by":"publisher","first-page":"1258","DOI":"10.3171\/2012.2.JNS111942","volume":"116","author":"AH Siddiqui","year":"2012","unstructured":"Siddiqui AH, Abla AA, Kan P, Dumont TM, Jahshan S, Britz GW, et al. Panacea or problem: flow diverters in the treatment of symptomatic large or giant fusiform vertebrobasilar aneurysms. J Neurosurg. 2012;116:1258\u201366.","journal-title":"J Neurosurg"},{"key":"699_CR30","doi-asserted-by":"publisher","first-page":"118","DOI":"10.3174\/ajnr.A5452","volume":"39","author":"N Lv","year":"2018","unstructured":"Lv N, Cao W, Larrabide I, Karmonik C, Zhu D, Liu J, et al. Hemodynamic changes caused by multiple stenting in vertebral artery fusiform aneurysms: a patient-specific computational fluid dynamics study. AJNR Am J Neuroradiol. 2018;39:118\u201322.","journal-title":"AJNR Am J Neuroradiol"},{"key":"699_CR31","doi-asserted-by":"publisher","first-page":"1288","DOI":"10.1136\/neurintsurg-2015-012154","volume":"8","author":"R Ouared","year":"2016","unstructured":"Ouared R, Larrabide I, Brina O, Bouillot P, Erceg G, Yilmaz H, et al. Computational fluid dynamics analysis of flow reduction induced by flow-diverting stents in intracranial aneurysms: a patient-unspecific hemodynamics change perspective. J Neurointerv Surg. 2016;8:1288\u201393.","journal-title":"J Neurointerv Surg."},{"key":"699_CR32","doi-asserted-by":"publisher","first-page":"1366","DOI":"10.1007\/s10439-012-0723-0","volume":"41","author":"JR Cebral","year":"2013","unstructured":"Cebral JR, Raschi M. Suggested connections between risk factors of intracranial aneurysms: a review. Ann Biomed Eng. 2013;41:1366\u201383.","journal-title":"Ann Biomed Eng"},{"key":"699_CR33","doi-asserted-by":"publisher","first-page":"1254","DOI":"10.3174\/ajnr.A3558","volume":"35","author":"H Meng","year":"2014","unstructured":"Meng H, Tutino VM, Xiang J, Siddiqui A. High WSS or low WSS? Complex interactions of hemodynamics with intracranial aneurysm initiation, growth, and rupture: toward a unifying hypothesis. AJNR Am J Neuroradiol. 2014;35:1254\u201362.","journal-title":"AJNR Am J Neuroradiol"},{"key":"699_CR34","doi-asserted-by":"publisher","first-page":"832","DOI":"10.3171\/2014.11.JNS14497","volume":"123","author":"J Xiang","year":"2015","unstructured":"Xiang J, Damiano RJ, Lin N, Snyder KV, Siddiqui AH, Levy EI, et al. High-fidelity virtual stenting: modeling of flow diverter deployment for hemodynamic characterization of complex intracranial aneurysms. J Neurosurg. 2015;123:832\u201340.","journal-title":"J Neurosurg"},{"key":"699_CR35","doi-asserted-by":"publisher","first-page":"144","DOI":"10.1161\/STROKEAHA.110.592923","volume":"42","author":"J Xiang","year":"2011","unstructured":"Xiang J, Natarajan SK, Tremmel M, Ma D, Mocco J, Hopkins LN, et al. Hemodynamic\u2013morphologic discriminants for intracranial aneurysm rupture. Stroke. 2011;42:144\u201352.","journal-title":"Stroke"},{"key":"699_CR36","doi-asserted-by":"publisher","first-page":"153","DOI":"10.1136\/neurintsurg-2018-014246","volume":"11","author":"L Liang","year":"2019","unstructured":"Liang L, Steinman DA, Brina O, Chnafa C, Cancelliere NM, Pereira VM. Towards the Clinical utility of CFD for assessment of intracranial aneurysm rupture\u2014a systematic review and novel parameter-ranking tool. J Neurointerv Surg. 2019;11:153\u20138.","journal-title":"J Neurointerv Surg."},{"key":"699_CR37","doi-asserted-by":"publisher","first-page":"317","DOI":"10.3233\/THC-161132","volume":"24","author":"SV Frolov","year":"2016","unstructured":"Frolov SV, Sindeev SV, Liepsch D, Balasso A. Experimental and CFD flow studies in an intracranial aneurysm model with Newtonian and non-Newtonian fluids. Technol Health Care. 2016;24:317\u201333.","journal-title":"Technol Health Care"},{"key":"699_CR38","doi-asserted-by":"publisher","first-page":"351","DOI":"10.1136\/neurintsurg-2011-010089","volume":"4","author":"J Xiang","year":"2012","unstructured":"Xiang J, Tremmel M, Kolega J, Levy EI, Natarajan SK, Meng H. Newtonian viscosity model could overestimate wall shear stress in intracranial aneurysm domes and underestimate rupture risk. J Neurointerv Surg. 2012;4:351\u20137.","journal-title":"J Neurointerv Surg."},{"key":"699_CR39","unstructured":"Yamaguchi R, Tanaka G, Liu H. Effect of elasticity on flow characteristics inside intracranial aneurysms. Int J Neurol Neurother. 2016. \n                              https:\/\/clinmedjournals.org\/articles\/ijnn\/international-journal-of-neurology-and-neurotherapy-ijnn-3-049.php?jid=ijnn\n                              \n                           . Accessed 22 Aug 2018."}],"container-title":["BioMedical Engineering OnLine"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s12938-019-0699-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1186\/s12938-019-0699-1\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s12938-019-0699-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,7,22]],"date-time":"2020-07-22T23:12:23Z","timestamp":1595459543000},"score":1,"resource":{"primary":{"URL":"https:\/\/biomedical-engineering-online.biomedcentral.com\/articles\/10.1186\/s12938-019-0699-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,7,24]]},"references-count":39,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2019,12]]}},"alternative-id":["699"],"URL":"https:\/\/doi.org\/10.1186\/s12938-019-0699-1","relation":{},"ISSN":["1475-925X"],"issn-type":[{"value":"1475-925X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,7,24]]},"assertion":[{"value":"23 January 2019","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"11 July 2019","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"24 July 2019","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"As our experiments were conducted retrospectively with permanently anonymized patient data, our local ethics committee deemed the study exempt from the requirement for approval.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"Other than the grants listed in the acknowledgement section, the authors declare that they have no competing interests.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"82"}}