{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,26]],"date-time":"2026-10-26T17:36:29Z","timestamp":1793036189897,"version":"4.5.0"},"reference-count":41,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2020,9,14]],"date-time":"2020-09-14T00:00:00Z","timestamp":1600041600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2020,9,14]],"date-time":"2020-09-14T00:00:00Z","timestamp":1600041600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BioMed Eng OnLine"],"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>Numerous sensing techniques have been investigated in an effort to monitor the main parameters influencing the residual limb\/prosthesis interface, fundamental to the optimum design of prosthetic socket solutions. Sensing integration within sockets is notoriously complex and can cause user discomfort. A personalised prosthetic liner with embedded sensors could offer a solution. However, to allow for a functional and comfortable instrumented liner, highly customised designs are needed. The aim of this paper is to presents a novel approach to manufacture fully personalised liners using scanned three-dimensional image data of the patient\u2019s residual limb, combined with designs that allow for sensor integration. To demonstrate the feasibility of the proposed approach, a personalised liner with embedded temperature and humidity sensors was realised and tested on a transtibial amputee, presented here as a case study.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>The residual limb of a below knee amputee was first scanned and a three-dimensional digital image created. The output was used to produce a personalised prosthesis. The liner was manufactured using a cryogenic Computer Numeric Control (CNC) machining approach. This method enables fast, direct and precise manufacture of soft elastomer products. Twelve Hygrochron Data Loggers, able to measure both temperature and humidity, were embedded in specific liner locations, ensuring direct sensor-skin contact. The sensor locations were machined directly into the liner, during the manufacturing process. The sensors outputs were assessed on the below amputee who took part in the study, during resting (50\u00a0min) and walking activities (30\u00a0min). To better describe the relative thermal properties of new liner, the same tests were repeated with the amputee wearing his existing liner. Quantitative comparisons of the thermal properties of the new liner solution with that currently used in clinical practice are, therefore, reported.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>The liner machining process took approximately 4\u00a0h. Fifteen minutes after donning the prosthesis, the skin temperature reached a plateau. Physical activity rapidly increased residuum skin temperatures, while cessation of activity caused a moderate decrease. Humidity increased throughout the observation period. In addition, the new liner showed better thermal properties with respect to the current liner solution (4% reduction in skin temperature).<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusions<\/jats:title>\n                <jats:p>This work describes a personalised liner solution, with embedded temperature and humidity sensors, developed through an innovative approach. This new method allows for a range of sensors to be smoothly embedded into a liner, which is capable of measuring changes in intra-socket microclimate conditions, resulting in the design of advanced socket solutions personalised specifically for individual requirements. In future, this method will not only provide a personalised liner but will also enable dynamic assessment of how a residual limb behaves within the socket during daily activities.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s12938-020-00814-y","type":"journal-article","created":{"date-parts":[[2020,9,14]],"date-time":"2020-09-14T12:02:53Z","timestamp":1600084973000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":25,"title":["A personalised prosthetic liner with embedded sensor technology: a case study"],"prefix":"10.1186","volume":"19","author":[{"given":"Linda","family":"Patern\u00f2","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Vimal","family":"Dhokia","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Arianna","family":"Menciassi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"James","family":"Bilzon","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6736-893X","authenticated-orcid":false,"given":"Elena","family":"Seminati","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2020,9,14]]},"reference":[{"issue":"2","key":"814_CR1","first-page":"161","volume":"38","author":"AF Mak","year":"2001","unstructured":"Mak AF, Zhang M, Boone DA. State-of-the-art research in lower-limb prosthetic biomechanics-socket interface: a review. JRRD. 2001;38(2):161\u201374.","journal-title":"JRRD"},{"issue":"2","key":"814_CR2","doi-asserted-by":"publisher","first-page":"146","DOI":"10.3109\/03093641003645528","volume":"34","author":"GK Klute","year":"2010","unstructured":"Klute GK, Glaister BC, Berge JS. Prosthetic liners for lower limb amputees: a review of the literature. Prosthet Orthot Int. 2010;34(2):146\u201353.","journal-title":"Prosthet Orthot Int"},{"key":"814_CR3","unstructured":"Kapp S, Miller JA \u201cChapter 20 Lower Limb Prosthetic.\u201d"},{"issue":"4","key":"814_CR4","first-page":"395","volume":"33","author":"Q He","year":"2015","unstructured":"He Q, Johnston J, Zeitlinger J, City K, City K. HHS Public Access\u201d. PLos ONE. 2015;33(4):395\u2013401.","journal-title":"PLos ONE."},{"issue":"7315","key":"814_CR5","doi-asserted-by":"publisher","first-page":"732","DOI":"10.1136\/bmj.323.7315.732","volume":"323","author":"LJ Marks","year":"2001","unstructured":"Marks LJ, Michael JW. Artificial limbs. BMJ. 2001;323(7315):732.","journal-title":"BMJ"},{"issue":"1","key":"814_CR6","doi-asserted-by":"publisher","first-page":"6","DOI":"10.1177\/0309364616631343","volume":"41","author":"A Richardson","year":"2017","unstructured":"Richardson A, Dillon MP. User experience of transtibial prosthetic liners: a systematic review. Prosthet Orthot Int. 2017;41(1):6\u201318.","journal-title":"Prosthet Orthot Int"},{"key":"814_CR7","unstructured":"\u201cCustom Fabrication of Injection Molded Renew\u2122 Silicone Liners.\u201dhttps:\/\/www.smooth-on.com\/tutorials\/custom-fabrication-injection-molded-renew-trade-silicone-liners\/. Accessed 12 Jun 2019."},{"issue":"4","key":"814_CR8","doi-asserted-by":"publisher","first-page":"591","DOI":"10.1682\/JRRD.2004.04.0591","volume":"41","author":"KL Coleman","year":"2004","unstructured":"Coleman KL, Boone DA, Laing LS, Mathews DE, Smith DG. Quantification of prosthetic outcomes: elastomeric gel liner with locking pin suspension versus polyethylene foam liner with neoprene sleeve suspension. J Rehabil Res Dev. 2004;41(4):591\u2013602.","journal-title":"J Rehabil Res Dev"},{"key":"814_CR9","doi-asserted-by":"crossref","unstructured":"Sanders J. \u201cStump-socket interface conditions\u201d in Pressure Ulcer Research: Current and Future Perspectives, 2005; 129\u2013147.","DOI":"10.1007\/3-540-28804-X_9"},{"issue":"3","key":"814_CR10","doi-asserted-by":"publisher","first-page":"292","DOI":"10.1080\/03093640601042554","volume":"31","author":"GK Klute","year":"2007","unstructured":"Klute GK, Rowe GI, Mamishev AV, Ledoux WR. The thermal conductivity of prosthetic sockets and liners. Prosthet Orthot Int. 2007;31(3):292\u20139.","journal-title":"Prosthet Orthot Int"},{"issue":"7","key":"814_CR11","doi-asserted-by":"publisher","first-page":"1119","DOI":"10.3390\/s16071119","volume":"16","author":"EA Al-Fakih","year":"2016","unstructured":"Al-Fakih EA, Abu Osman NA, Mahmad Adikan FR. Techniques for interface stress measurements within prosthetic sockets of transtibial amputees: a review of the past 50\u00a0years of research. Sensors. 2016;16(7):1119.","journal-title":"Sensors."},{"issue":"9","key":"814_CR12","doi-asserted-by":"publisher","first-page":"1996","DOI":"10.1109\/TBME.2017.2775100","volume":"65","author":"L Paterno","year":"2018","unstructured":"Paterno L, Ibrahimi M, Gruppioni E, Menciassi A, Ricotti L. Sockets for limb prostheses: a review of existing technologies and open challenges. IEEE Trans Biomed Eng. 2018;65(9):1996\u20132010.","journal-title":"IEEE Trans Biomed Eng"},{"issue":"S2","key":"814_CR13","doi-asserted-by":"publisher","first-page":"145","DOI":"10.1186\/s12938-018-0577-2","volume":"17","author":"C-H Hsu","year":"2018","unstructured":"Hsu C-H, Ou C-H, Hong W-L, Gao Y-H. Comfort level discussion for prosthetic sockets with different fabricating processing conditions. Biomed Eng Online. 2018;17(S2):145.","journal-title":"Biomed Eng Online"},{"issue":"2","key":"814_CR14","doi-asserted-by":"publisher","first-page":"141","DOI":"10.1682\/JRRD.2004.08.0134","volume":"42","author":"N Herbert","year":"2005","unstructured":"Herbert N, Simpson D, Spence WD, Ion W. A preliminary investigation into the development of 3-D printing of prosthetic sockets. J Rehabil Res Dev. 2005;42(2):141.","journal-title":"J Rehabil Res Dev"},{"key":"814_CR15","doi-asserted-by":"crossref","unstructured":"Comotti C, Regazzoni D, Rizzi C, Vitali A. Multi-material design and 3D printing method of lower limb prosthetic sockets,\u201d in ACM International Conference Proceeding Series. 2015; 42-45).","DOI":"10.1145\/2838944.2838955"},{"issue":"3","key":"814_CR16","doi-asserted-by":"publisher","first-page":"129","DOI":"10.1097\/JPO.0b013e31829be19c","volume":"25","author":"DM Sengeh","year":"2013","unstructured":"Sengeh DM, Herr H. A variable-impedance prosthetic socket for a transtibial amputee designed from magnetic resonance imaging data. J. Prosthetics Orthosis. 2013;25(3):129\u201337.","journal-title":"J. Prosthetics Orthosis"},{"issue":"3","key":"814_CR17","doi-asserted-by":"publisher","first-page":"1","DOI":"10.4015\/S1016237216500228","volume":"28","author":"C Nayak","year":"2016","unstructured":"Nayak C, Singh A, Chaudhary H, Tripathi A. A novel approach for customized prosthetic socket design. Biomed Eng Appl Basis Commun. 2016;28(3):1\u201310.","journal-title":"Biomed Eng Appl Basis Commun."},{"issue":"5","key":"814_CR18","doi-asserted-by":"publisher","first-page":"1","DOI":"10.4015\/S1016237215500441","volume":"27","author":"MJ Tzeng","year":"2015","unstructured":"Tzeng MJ, Hsu LH, Chang SH. Development and evaluation of a CAD\/3DP process for transtibial socket fabrication. Biomed Eng Appl Basis Commun. 2015;27(5):1\u20139.","journal-title":"Biomed Eng Appl Basis Commun."},{"issue":"6","key":"814_CR19","doi-asserted-by":"publisher","first-page":"513","DOI":"10.1016\/j.compind.2010.03.008","volume":"61","author":"G Colombo","year":"2010","unstructured":"Colombo G, Filippi S, Rizzi C, Rotini F. Computers in Industry A new design paradigm for the development of custom-fit soft sockets for lower limb prostheses. Comput Ind. 2010;61(6):513\u201323.","journal-title":"Comput Ind"},{"issue":"7633","key":"814_CR20","doi-asserted-by":"publisher","first-page":"371","DOI":"10.1038\/nature21003","volume":"540","author":"RL Truby","year":"2016","unstructured":"Truby RL, Lewis JA. Printing soft matter in three dimensions. Nature. 2016;540(7633):371\u20138.","journal-title":"Nature"},{"issue":"1","key":"814_CR21","doi-asserted-by":"publisher","first-page":"243","DOI":"10.1080\/14686996.2018.1431862","volume":"19","author":"JZ Gul","year":"2018","unstructured":"Gul JZ, et al. 3D printing for soft robotics\u2013a review. Sci Technol Advanc Mater. 2018;19(1):243\u201362.","journal-title":"Sci Technol Advanc Mater"},{"key":"814_CR22","doi-asserted-by":"publisher","first-page":"476","DOI":"10.1016\/j.procir.2017.02.049","volume":"60","author":"V Dhokia","year":"2017","unstructured":"Dhokia V, Bilzon J, Seminati E, Talamas DC, Young M, Mitchell W. The design and manufacture of a prototype personalized liner for lower limb amputees. Procedia CIRP. 2017;60:476\u201381.","journal-title":"Procedia CIRP"},{"issue":"6","key":"814_CR23","doi-asserted-by":"publisher","first-page":"972","DOI":"10.1016\/j.rcim.2009.04.016","volume":"25","author":"P Crabtree","year":"2009","unstructured":"Crabtree P, Dhokia VG, Newman ST, Ansell MP. Manufacturing methodology for personalised symptom-specific sports insoles. Robot Comput Integr Manuf. 2009;25(6):972\u20139.","journal-title":"Robot Comput Integr Manuf."},{"key":"814_CR24","unstructured":"Selinger D. Weight of prefabricated transtibial gel prosthetic liners a standardized sample."},{"issue":"1","key":"814_CR25","doi-asserted-by":"publisher","first-page":"132","DOI":"10.1016\/j.medengphy.2014.10.002","volume":"37","author":"P Laszczak","year":"2015","unstructured":"Laszczak P, Jiang L, Bader DL, Moser D, Zahedi S. Development and validation of a 3D-printed interfacial stress sensor for prosthetic applications. Med Eng Phys. 2015;37(1):132\u20137.","journal-title":"Med Eng Phys"},{"issue":"7","key":"814_CR26","doi-asserted-by":"publisher","first-page":"695","DOI":"10.1016\/j.medengphy.2016.04.007","volume":"38","author":"P Laszczak","year":"2016","unstructured":"Laszczak P, et al. A pressure and shear sensor system for stress measurement at lower limb residuum\/socket interface. Med Eng Phys. 2016;38(7):695\u2013700.","journal-title":"Med Eng Phys"},{"issue":"10","key":"814_CR27","doi-asserted-by":"publisher","first-page":"3062","DOI":"10.1007\/s11999-014-3741-4","volume":"472","author":"GK Klute","year":"2014","unstructured":"Klute GK, Huff E, Ledoux WR. Does activity affect residual limb skin temperatures? Clin Orthop Relat Res. 2014;472(10):3062\u20137.","journal-title":"Clin Orthop Relat Res"},{"issue":"4","key":"814_CR28","doi-asserted-by":"publisher","first-page":"170","DOI":"10.1097\/JPO.0b013e3181875b17","volume":"20","author":"EA Huff","year":"2008","unstructured":"Huff EA, Ledoux WR, Berge JS, Klute GK. Measuring residual limb skin temperatures at the skin-prosthesis interface. JPO J Prosthetics Orthot. 2008;20(4):170\u20133.","journal-title":"JPO J Prosthetics Orthot."},{"issue":"2","key":"814_CR29","doi-asserted-by":"publisher","first-page":"147","DOI":"10.1682\/JRRD.2004.01.0013","volume":"42","author":"JT Peery","year":"2005","unstructured":"Peery JT, Ledoux WR, Klute GK. Residual-limb skin temperature in transtibial sockets. J Rehabil Res Dev. 2005;42(2):147\u201354.","journal-title":"J Rehabil Res Dev"},{"issue":"5","key":"814_CR30","doi-asserted-by":"publisher","first-page":"603","DOI":"10.4065\/78.5.603","volume":"78","author":"N Charkoudian","year":"2003","unstructured":"Charkoudian N. Skin blood flow in adult human thermoregulation: how it works, when it does not, and why. Mayo Clin Proceed. 2003;78(5):603\u201312.","journal-title":"Mayo Clin Proceed"},{"issue":"3","key":"814_CR31","doi-asserted-by":"publisher","first-page":"5041","DOI":"10.3390\/s140305041","volume":"14","author":"A Cutti","year":"2014","unstructured":"Cutti A, Perego P, Fusca M, Sacchetti R, Andreoni G. Assessment of lower limb prosthesis through wearable sensors and thermography. Sensors. 2014;14(3):5041\u201355.","journal-title":"Sensors"},{"key":"814_CR32","doi-asserted-by":"publisher","first-page":"94","DOI":"10.1016\/j.medengphy.2019.04.003","volume":"68","author":"JE Sanders","year":"2019","unstructured":"Sanders JE, et al. A motor-driven adjustable prosthetic socket operated using a mobile phone app: a technical note. Med Eng Phys. 2019;68:94\u2013100.","journal-title":"Med Eng Phys"},{"key":"814_CR33","unstructured":"\u201cDS1923 iButton hygrochron temperature\/humidity logger with 8\u00a0kb datalog memory absolute maximum ratings electrical characteristics. https:\/\/datasheets.maximintegrated.com\/en\/ds\/DS1923.pdf. Accessed 25 Jul 2020."},{"key":"814_CR34","doi-asserted-by":"publisher","first-page":"208","DOI":"10.1016\/j.physbeh.2017.06.019","volume":"179","author":"M Shin","year":"2017","unstructured":"Shin M, Patton R, Mahar T, Ireland A, Swan P, Chow CM. Calibration and validation processes for relative humidity measurement by a Hygrochron iButton. Physiol Behav. 2017;179:208\u201312.","journal-title":"Physiol Behav"},{"issue":"4\u20135","key":"814_CR35","doi-asserted-by":"publisher","first-page":"489","DOI":"10.1016\/j.physbeh.2006.04.026","volume":"88","author":"WD van Marken Lichtenbelt","year":"2006","unstructured":"van Marken Lichtenbelt WD, et al. Evaluation of wireless determination of skin temperature using iButtons. Physiol Behav. 2006;88(4\u20135):489\u201397.","journal-title":"Physiol Behav."},{"issue":"9","key":"814_CR36","doi-asserted-by":"publisher","first-page":"e0184498","DOI":"10.1371\/journal.pone.0184498","volume":"12","author":"E Seminati","year":"2017","unstructured":"Seminati E, Canepa Talamas D, Young M, Twiste M, Dhokia V, Bilzon JLJ. Validity and reliability of a novel 3D scanner for assessment of the shape and volume of amputees\u2019 residual limb models. PLoS ONE. 2017;12(9):e0184498.","journal-title":"PLoS ONE"},{"key":"814_CR37","unstructured":"Seminati E, et al. Residuum volume and shape assessment after lower limb amputation: validity and reliability of a new structured light 3D scanner,\u201d 16th World Congr. Int Soc Prosthetics Orthot ISPO 2017; 316."},{"issue":"9","key":"814_CR38","doi-asserted-by":"publisher","first-page":"1482","DOI":"10.1177\/0954405411415318","volume":"225","author":"VG Dhokia","year":"2011","unstructured":"Dhokia VG, Newman ST, Crabtree P, Ansell MP. Adiabatic shear band formation as a result of cryogenic CNC machining of elastomers. Proc Inst Mech Eng Part B J Eng Manuf. 2011;225(9):1482\u201392.","journal-title":"Proc Inst Mech Eng Part B J Eng Manuf."},{"key":"814_CR39","unstructured":"\u201cMulti-Spectral Dynamic Imaging | FLIR Systems.\u201d https:\/\/www.flir.eu\/instruments\/multi-spectral-dynamic-imaging\/. Accessed 14 Jan 2020]."},{"issue":"22","key":"814_CR40","doi-asserted-by":"publisher","first-page":"1278","DOI":"10.1080\/09638280310001603983","volume":"25","author":"RS Hanspal","year":"2003","unstructured":"Hanspal RS, Fisher K, Nieveen R. Prosthetic socket fit comfort score. Disabil Rehabil. 2003;25(22):1278\u201380.","journal-title":"Disabil Rehabil"},{"key":"814_CR41","doi-asserted-by":"crossref","unstructured":"Use of the Prosthesis evaluation questionnaire (PEQ). JPO J. Prosthetics Orthot. 2006; 18(6): 68\u2013P79.","DOI":"10.1097\/00008526-200601001-00008"}],"updated-by":[{"DOI":"10.1186\/s12938-023-01154-3","type":"correction","label":"Correction","source":"publisher","updated":{"date-parts":[[2023,9,21]],"date-time":"2023-09-21T00:00:00Z","timestamp":1695254400000}}],"container-title":["BioMedical Engineering OnLine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12938-020-00814-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12938-020-00814-y\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12938-020-00814-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,22]],"date-time":"2023-09-22T06:02:43Z","timestamp":1695362563000},"score":1,"resource":{"primary":{"URL":"https:\/\/biomedical-engineering-online.biomedcentral.com\/articles\/10.1186\/s12938-020-00814-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,9,14]]},"references-count":41,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2020,12]]}},"alternative-id":["814"],"URL":"https:\/\/doi.org\/10.1186\/s12938-020-00814-y","relation":{"correction":[{"id-type":"doi","id":"10.1186\/s12938-023-01154-3","asserted-by":"object"}]},"ISSN":["1475-925X"],"issn-type":[{"value":"1475-925X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,9,14]]},"assertion":[{"value":"8 March 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"4 September 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"14 September 2020","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"21 September 2023","order":4,"name":"change_date","label":"Change Date","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Correction","order":5,"name":"change_type","label":"Change Type","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"A Correction to this paper has been published:","order":6,"name":"change_details","label":"Change Details","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"https:\/\/doi.org\/10.1186\/s12938-023-01154-3","URL":"https:\/\/doi.org\/10.1186\/s12938-023-01154-3","order":7,"name":"change_details","label":"Change Details","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Ethics approval and consent to participate approval was obtained from the Research Ethics Approval Committee (REACH) of the Department for Health of the University of Bath.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Written informed consent for publication was obtained from the participant of this study, as approved by the REACH committee (see previous statement).","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they have no competing interests.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"71"}}