{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,2]],"date-time":"2026-11-02T20:03:54Z","timestamp":1793649834717,"version":"4.5.1"},"reference-count":46,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2022,6,10]],"date-time":"2022-06-10T00:00:00Z","timestamp":1654819200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,6,10]],"date-time":"2022-06-10T00:00:00Z","timestamp":1654819200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/100016692","name":"key research and development program of Ningxia Hui Autonomous Region","doi-asserted-by":"crossref","award":["2020BEG03038"],"award-info":[{"award-number":["2020BEG03038"]}],"id":[{"id":"10.13039\/100016692","id-type":"DOI","asserted-by":"crossref"}]},{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"crossref","award":["82060331"],"award-info":[{"award-number":["82060331"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"crossref"}]},{"DOI":"10.13039\/501100004772","name":"Natural Science Foundation of Ningxia","doi-asserted-by":"crossref","award":["2020A0459"],"award-info":[{"award-number":["2020A0459"]}],"id":[{"id":"10.13039\/501100004772","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BioMed Eng OnLine"],"published-print":{"date-parts":[[2022,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>There are a variety of internal fixation methods for unstable femoral neck fractures (FNFs), but the best method is still unclear. Femoral neck system (FNS) is a dynamic angular stabilization system with cross screws, and is a new internal fixation implant designed for minimally invasive fixation of FNFs. In this study, we conducted a biomechanical comparison of FNS, InterTan nail and three cannulated screws for the treatment of Pauwels III FNFs and investigate the biomechanical properties of FNS.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>A total of 18 left artificial femurs were selected and randomly divide into Group A (fixation with FNS), Group B (fixation with InterTan nail) and Group C (fixation with three cannulated screws), with 6 specimens in each group. After creating Pauwels type III FNF models, the specimens in each were tested with non-destructive quasi-static tests, including torsion, A-P bending and axial compression tests. The average slope of the linear load\u2013deformation curve obtained from quasi-static tests defines the initial torsional stiffness, A-P bending stiffness, and axial compression stiffness. After cyclic loading test was applied, the overall deformation of models and local deformation of implant holes in each group were assessed. The overall deformation was estimated as the displacement recorded by the software of the mechanical testing apparatus. Local deformation was defined as interfragmental displacement. Data were analyzed by one-way analysis of variance (ANOVA) followed by Bonferroni post hoc test using the SPSS software (version 24.0, IBM, New York, NY, USA). Correlation analysis was performed using Pearson\u2019s correlation analysis.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>Group B exhibited significantly higher axial stiffness and A-P bending stiffness than the other two groups (<jats:italic>P<\/jats:italic>\u2009&lt;\u20090.01), while Group A had significantly higher axial stiffness and A-P bending stiffness than Group C (<jats:italic>P<\/jats:italic>\u2009&lt;\u20090.01). Groups A and B exhibited significantly higher torsional stiffness than Group C (<jats:italic>P<\/jats:italic>\u2009&lt;\u20090.01), no statistical significance was observed between Groups A and B (<jats:italic>P<\/jats:italic>\u2009&gt;\u20090.05). Group B exhibited significantly lower overall and local deformations than the other two groups (<jats:italic>P<\/jats:italic>\u2009&lt;\u20090.01), while Group A had significantly lower overall and local deformations than Group C (<jats:italic>P<\/jats:italic>\u2009&lt;\u20090.01). Correlation analysis revealed positive correlation between axial stiffness and A-P bending stiffness (<jats:italic>r<\/jats:italic>\u2009=\u20090.925, <jats:italic>P<\/jats:italic>\u2009&lt;\u20090.01), torsional stiffness (<jats:italic>r<\/jats:italic>\u2009=\u20090.727, <jats:italic>P<\/jats:italic>\u2009&lt;\u20090.01), between torsional stiffness and A-P bending stiffness; negative correlation between overall, local deformations and axial stiffness (<jats:italic>r<\/jats:italic>\u2009=\u2009\u2212\u20090.889, \u2212\u20090.901, respectively, both <jats:italic>P<\/jats:italic>\u2009&lt;\u20090.01), and positive correlation between the two deformations (<jats:italic>r<\/jats:italic>\u2009=\u2009\u2212\u20090.978, <jats:italic>P<\/jats:italic>\u2009&lt;\u20090.01).<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusion<\/jats:title>\n                <jats:p>For fixation of unstable FNFs, InterTan nail showed the highest axial stiffness and A-P bending stiffness, followed by FNS, and then three cannulated screws. Torsional stiffness of FNS was comparable to that of the InterTan nail. FNS, as a novel minimally invasive implant, can create good mechanical environment for the healing of unstable FNFs. Clinical studies are needed to confirm the potential advantages of FNS observed in this biomechanical study.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s12938-022-01006-6","type":"journal-article","created":{"date-parts":[[2022,6,10]],"date-time":"2022-06-10T15:04:04Z","timestamp":1654873444000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":32,"title":["Biomechanical comparison of the femoral neck system versus InterTan nail and three cannulated screws for unstable Pauwels type III femoral neck fracture"],"prefix":"10.1186","volume":"21","author":[{"given":"Zheng","family":"Wang","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yong","family":"Yang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gangning","family":"Feng","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Haohui","family":"Guo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zhirong","family":"Chen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yaogeng","family":"Chen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Qunhua","family":"Jin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2022,6,10]]},"reference":[{"issue":"Suppl 3","key":"1006_CR1","doi-asserted-by":"publisher","first-page":"C1","DOI":"10.1016\/S0020-1383(02)00324-8","volume":"33","author":"K Thorngren","year":"2002","unstructured":"Thorngren K, Hommel A, Norrman PO, et al. Epidemiology of femoral neck fractures. Injury. 2002;33(Suppl 3):C1-7.","journal-title":"Injury"},{"issue":"7","key":"1006_CR2","doi-asserted-by":"publisher","first-page":"937","DOI":"10.1302\/0301-620X.82B7.0820937","volume":"82","author":"MJ Parker","year":"2000","unstructured":"Parker MJ. The management of intracapsular fractures of the proximal femur. J Bone Joint Surg Br. 2000;82(7):937\u201341.","journal-title":"J Bone Joint Surg Br"},{"issue":"3","key":"1006_CR3","doi-asserted-by":"publisher","first-page":"484","DOI":"10.1016\/j.injury.2014.10.010","volume":"46","author":"G Slobogean","year":"2015","unstructured":"Slobogean G, Sprague SA, Scott T, et al. Complications following young femoral neck fractures. Injury. 2015;46(3):484\u201391.","journal-title":"Injury"},{"issue":"6","key":"1006_CR4","doi-asserted-by":"publisher","first-page":"549","DOI":"10.1016\/j.injury.2011.03.037","volume":"42","author":"PV Giannoudis","year":"2011","unstructured":"Giannoudis PV, Jones E, Einhorn TA. Fracture healing and bone repair. Injury. 2011;42(6):549\u201350.","journal-title":"Injury"},{"issue":"3","key":"1006_CR5","doi-asserted-by":"publisher","first-page":"283","DOI":"10.1016\/j.injury.2008.08.041","volume":"40","author":"WH Roerdink","year":"2009","unstructured":"Roerdink WH, Aalsma AM, Nijenbanning G, et al. The dynamic locking blade plate, a new implant for intracapsular hip fractures: biomechanical comparison with the sliding hip screw and twin hook. Injury. 2009;40(3):283\u20137.","journal-title":"Injury"},{"issue":"11","key":"1006_CR6","doi-asserted-by":"publisher","first-page":"954","DOI":"10.1007\/s00132-017-3473-8","volume":"46","author":"LL Zhang","year":"2017","unstructured":"Zhang LL, Zhang Y, Ma X, et al. Multiple cannulated screws vs. dynamic hip screws for femoral neck fractures: a meta-analysis. Orthopade. 2017;46(11):954\u201362.","journal-title":"Orthopade"},{"issue":"3","key":"1006_CR7","doi-asserted-by":"publisher","first-page":"303","DOI":"10.3109\/17453670902967281","volume":"80","author":"H Palm","year":"2009","unstructured":"Palm H, Gosvig K, Krasheninnikoff M, et al. A new measurement for posterior tilt predicts reoperation in undisplaced femoral neck fractures: 113 consecutive patients treated by internal fixation and followed for 1\u00a0year. Acta Orthop. 2009;80(3):303\u20137.","journal-title":"Acta Orthop"},{"issue":"3","key":"1006_CR8","doi-asserted-by":"publisher","first-page":"201","DOI":"10.3109\/17453679108993593","volume":"62","author":"JI Ragnarsson","year":"1991","unstructured":"Ragnarsson JI, K\u00e4rrholm J. Stability of femoral neck fracture. Roentgen stereophotogrammetry of 29 hook-pinned fractures. Acta Orthop Scand. 1991;62(3):201\u20137.","journal-title":"Acta Orthop Scand"},{"issue":"2","key":"1006_CR9","doi-asserted-by":"publisher","first-page":"152","DOI":"10.1097\/00005131-199206000-00004","volume":"6","author":"JI Ragnarsson","year":"1992","unstructured":"Ragnarsson JI, K\u00e4rrholm J. Factors influencing postoperative movement in displaced femoral neck fractures: evaluation by conventional radiography and stereoradiography. J Orthop Trauma. 1992;6(2):152\u20138.","journal-title":"J Orthop Trauma"},{"issue":"2","key":"1006_CR10","doi-asserted-by":"publisher","first-page":"409","DOI":"10.1007\/s00264-017-3587-y","volume":"42","author":"M Knobe","year":"2018","unstructured":"Knobe M, Altgassen S, Maier KJ, et al. Screw-blade fixation systems in Pauwels three femoral neck fractures: a biomechanical evaluation. Int Orthop. 2018;42(2):409\u201318.","journal-title":"Int Orthop"},{"issue":"2","key":"1006_CR11","doi-asserted-by":"publisher","first-page":"292","DOI":"10.1016\/j.injury.2018.10.038","volume":"50","author":"M Knobe","year":"2019","unstructured":"Knobe M, Bettag S, Kammerlander C, et al. Is bone-cement augmentation of screw-anchor fixation systems superior in unstable femoral neck fractures? A biomechanical cadaveric study. Injury. 2019;50(2):292\u2013300.","journal-title":"Injury"},{"issue":"9","key":"1006_CR12","doi-asserted-by":"publisher","first-page":"e221","DOI":"10.1097\/BOT.0000000000000080","volume":"28","author":"K Luttrell","year":"2014","unstructured":"Luttrell K, Beltran M, Collinge CA. Preoperative decision making in the treatment of high-angle \u201cvertical\u201d femoral neck fractures in young adult patients. An expert opinion survey of the Orthopaedic Trauma Association\u2019s (OTA) membership. J Orthop Trauma. 2014;28(9):e221\u20135. https:\/\/doi.org\/10.1097\/BOT.0000000000000080.","journal-title":"J Orthop Trauma"},{"issue":"4","key":"1006_CR13","doi-asserted-by":"publisher","first-page":"297","DOI":"10.5435\/JAAOS-D-15-00661","volume":"25","author":"G Slobogean","year":"2017","unstructured":"Slobogean G, Stockton DJ, Zeng B, et al. Femoral neck fractures in adults treated with internal fixation: a prospective multicenter chinese cohort. J Am Acad Orthop Surg. 2017;25(4):297\u2013303.","journal-title":"J Am Acad Orthop Surg"},{"issue":"3","key":"1006_CR14","doi-asserted-by":"publisher","first-page":"131","DOI":"10.1097\/BOT.0000000000000739","volume":"31","author":"K Stoffel","year":"2017","unstructured":"Stoffel K, Zderic I, Gras F, et al. Biomechanical evaluation of the femoral neck system in unstable pauwels III femoral neck fractures: a comparison with the dynamic hip screw and cannulated screws. J Orthop Trauma. 2017;31(3):131\u20137.","journal-title":"J Orthop Trauma"},{"issue":"1","key":"1006_CR15","doi-asserted-by":"publisher","first-page":"22","DOI":"10.1097\/BOT.0b013e31819211b2","volume":"23","author":"AH Ruecker","year":"2009","unstructured":"Ruecker AH, Rupprecht M, Gruber M, Gebauer M, Barvencik F, Briem D, Rueger JM. The treatment of intertrochanteric fractures: results using an intramedullary nail with integrated cephalocervical screws and linear compression. J Orthop Trauma. 2009;23(1):22\u201330. https:\/\/doi.org\/10.1097\/BOT.0b013e31819211b2.","journal-title":"J Orthop Trauma"},{"issue":"3","key":"1006_CR16","first-page":"625","volume":"71","author":"M Rupprecht","year":"2011","unstructured":"Rupprecht M, Grossterlinden L, Ruecker AH, et al. A comparative biomechanical analysis of fixation devices for unstable femoral neck fractures: the Intertan versus cannulated screws or a dynamic hip screw. J Trauma. 2011;71(3):625\u201334.","journal-title":"J Trauma"},{"issue":"9","key":"1006_CR17","doi-asserted-by":"publisher","first-page":"933","DOI":"10.1016\/S0021-9290(97)00057-2","volume":"30","author":"GN Duda","year":"1997","unstructured":"Duda GN, Schneider E, Chao EY. Internal forces and moments in the femur during walking. J Biomech. 1997;30(9):933\u201341.","journal-title":"J Biomech"},{"issue":"6","key":"1006_CR18","first-page":"1537","volume":"69","author":"R Zdero","year":"2010","unstructured":"Zdero R, Keast-Butler O, Schemitsch EH, et al. A biomechanical comparison of two triple-screw methods for femoral neck fracture fixation in a synthetic bone model. J Trauma. 2010;69(6):1537\u201344.","journal-title":"J Trauma"},{"key":"1006_CR19","doi-asserted-by":"publisher","first-page":"28","DOI":"10.1016\/j.clinbiomech.2018.03.024","volume":"55","author":"JE Brattgjerd","year":"2018","unstructured":"Brattgjerd JE, Loferer M, Niratisairak S, et al. Increased torsional stability by a novel femoral neck locking plate. The role of plate design and pin configuration in a synthetic bone block model. Clin Biomech (Bristol, Avon). 2018;55:28\u201335.","journal-title":"Clin Biomech (Bristol, Avon)"},{"issue":"2","key":"1006_CR20","doi-asserted-by":"publisher","first-page":"213","DOI":"10.1016\/j.clinbiomech.2013.11.008","volume":"29","author":"T Basso","year":"2014","unstructured":"Basso T, Klaksvik J, Foss OA. The effect of interlocking parallel screws in subcapital femoral-neck fracture fixation: a cadaver study. Clin Biomech (Bristol, Avon). 2014;29(2):213\u20137.","journal-title":"Clin Biomech (Bristol, Avon)"},{"issue":"5","key":"1006_CR21","doi-asserted-by":"publisher","first-page":"595","DOI":"10.1016\/j.clinbiomech.2014.03.006","volume":"29","author":"T Basso","year":"2014","unstructured":"Basso T, Klaksvik J, Foss OA. Locking plates and their effects on healing conditions and stress distribution: a femoral neck fracture study in cadavers. Clin Biomech (Bristol, Avon). 2014;29(5):595\u20138.","journal-title":"Clin Biomech (Bristol, Avon)"},{"key":"1006_CR22","doi-asserted-by":"publisher","first-page":"300","DOI":"10.1097\/00003086-199910000-00037","volume":"367","author":"AC Baitner","year":"1999","unstructured":"Baitner AC, Maurer SG, Hickey DG, et al. Vertical shear fractures of the femoral neck. A biomechanical study. Clin Orthop Relat Res. 1999;367:300\u20135.","journal-title":"Clin Orthop Relat Res"},{"issue":"5","key":"1006_CR23","doi-asserted-by":"publisher","first-page":"566","DOI":"10.1007\/s40846-015-0085-9","volume":"35","author":"S Samsami","year":"2015","unstructured":"Samsami S, Saberi S, Sadighi S, et al. Comparison of three fixation methods for femoral neck fracture in young adults: experimental and numerical investigations. J Med Biol Eng. 2015;35(5):566\u201379.","journal-title":"J Med Biol Eng"},{"issue":"8","key":"1006_CR24","doi-asserted-by":"publisher","first-page":"544","DOI":"10.1097\/BOT.0b013e31814b822e","volume":"21","author":"A Aminian","year":"2007","unstructured":"Aminian A, Gao F, Fedoriw WW, et al. Vertically oriented femoral neck fractures: mechanical analysis of four fixation techniques. J Orthop Trauma. 2007;21(8):544\u20138.","journal-title":"J Orthop Trauma"},{"issue":"1","key":"1006_CR25","doi-asserted-by":"publisher","first-page":"1","DOI":"10.4055\/cios.2019.11.1.1","volume":"11","author":"YH Cha","year":"2019","unstructured":"Cha YH, Yoo JI, Hwang SY, et al. Biomechanical evaluation of internal fixation of pauwels type III femoral neck fractures: a systematic review of various fixation methods. Clin Orthop Surg. 2019;11(1):1\u201314.","journal-title":"Clin Orthop Surg"},{"issue":"4","key":"1006_CR26","doi-asserted-by":"publisher","first-page":"1030","DOI":"10.2106\/JBJS.H.01532","volume":"92","author":"EH Schemitsch","year":"2010","unstructured":"Schemitsch EH, Bhandari M, Boden SD, et al. The evidence-based approach in bringing new orthopaedic devices to market. J Bone Joint Surg Am. 2010;92(4):1030\u20137.","journal-title":"J Bone Joint Surg Am"},{"issue":"10","key":"1006_CR27","doi-asserted-by":"publisher","first-page":"e170","DOI":"10.1097\/BOT.0b013e31823b4cd1","volume":"26","author":"M Berkes","year":"2012","unstructured":"Berkes M, Little MT, Lazaro LE, et al. Catastrophic failure after open reduction internal fixation of femoral neck fractures with a novel locking plate implant. J Orthop Trauma. 2012;26(10):e170-176.","journal-title":"J Orthop Trauma"},{"issue":"3","key":"1006_CR28","doi-asserted-by":"publisher","first-page":"595","DOI":"10.1007\/s00264-013-2176-y","volume":"38","author":"R Biber","year":"2014","unstructured":"Biber R, Brem M, Bail HJ. Targon Femoral Neck for femoral-neck fracture fixation: lessons learnt from a series of one hundred and thirty five consecutive cases. Int Orthop. 2014;38(3):595\u20139.","journal-title":"Int Orthop"},{"issue":"11","key":"1006_CR29","doi-asserted-by":"publisher","first-page":"2555","DOI":"10.1016\/j.injury.2017.08.063","volume":"48","author":"Z Alshameeri","year":"2017","unstructured":"Alshameeri Z, Elbashir M, Parker MJ. The outcome of intracapsular hip fracture fixation using the Targon Femoral Neck (TFN) locking plate system or cannulated cancellous screws: a comparative study involving 2004 patients. Injury. 2017;48(11):2555\u201362.","journal-title":"Injury"},{"key":"1006_CR30","first-page":"30","volume":"52","author":"H Yin","year":"2018","unstructured":"Yin H, Pan Z, Jiang H. Is dynamic locking plate(Targon FN) a better choice for treating of intracapsular hip fracture? A meta-analysis Int J Surg. 2018;52:30\u20134.","journal-title":"A meta-analysis Int J Surg"},{"issue":"6","key":"1006_CR31","doi-asserted-by":"publisher","first-page":"1802","DOI":"10.1111\/os.13098","volume":"13","author":"XQ Zhou","year":"2021","unstructured":"Zhou XQ, Li ZQ, Xu RJ, et al. Comparison of early clinical results for femoral neck system and cannulated screws in the treatment of unstable femoral neck fractures. Orthop Surg. 2021;13(6):1802\u20139.","journal-title":"Orthop Surg"},{"issue":"1","key":"1006_CR32","doi-asserted-by":"publisher","first-page":"12","DOI":"10.1115\/1.2401178","volume":"129","author":"M Papini","year":"2007","unstructured":"Papini M, Zdero R, Schemitsch EH, et al. The biomechanics of human femurs in axial and torsional loading: comparison of finite element analysis, human cadaveric femurs, and synthetic femurs. J Biomech Eng. 2007;129(1):12\u20139.","journal-title":"J Biomech Eng"},{"issue":"16","key":"1006_CR33","doi-asserted-by":"publisher","first-page":"3898","DOI":"10.1016\/j.jbiomech.2014.10.025","volume":"47","author":"T Basso","year":"2014","unstructured":"Basso T, Klaksvik J, Syversen U, et al. A biomechanical comparison of composite femurs and cadaver femurs used in experiments on operated hip fractures. J Biomech. 2014;47(16):3898\u2013902.","journal-title":"J Biomech"},{"issue":"9","key":"1006_CR34","doi-asserted-by":"publisher","first-page":"841","DOI":"10.1016\/S0021-9290(98)00080-3","volume":"31","author":"GN Duda","year":"1998","unstructured":"Duda GN, Heller M, Albinger J, et al. Influence of muscle forces on femoral strain distribution. J Biomech. 1998;31(9):841\u20136.","journal-title":"J Biomech"},{"key":"1006_CR35","doi-asserted-by":"publisher","first-page":"207","DOI":"10.1097\/01.blo.0000238867.15228.8d","volume":"454","author":"M Heetveld","year":"2007","unstructured":"Heetveld M, Raaymakers EL, Luitse JS, et al. Rating of internal fixation and clinical outcome in displaced femoral neck fractures: a prospective multicenter study. Clin Orthop Relat Res. 2007;454:207\u201313.","journal-title":"Clin Orthop Relat Res"},{"key":"1006_CR36","doi-asserted-by":"publisher","first-page":"59","DOI":"10.1097\/00003086-200206000-00009","volume":"399","author":"U Bosch","year":"2002","unstructured":"Bosch U, Schreiber T, Krettek C, et al. Reduction and fixation of displaced intracapsular fractures of the proximal femur. Clin Orthop Relat Res. 2002;399:59\u201371.","journal-title":"Clin Orthop Relat Res"},{"issue":"7","key":"1006_CR37","doi-asserted-by":"publisher","first-page":"1058","DOI":"10.2106\/00004623-199507000-00012","volume":"77","author":"M Baumgaertner","year":"1995","unstructured":"Baumgaertner M, Curtin SL, Lindskog DM, et al. The value of the tip-apex distance in predicting failure of fixation of peritrochanteric fractures of the hip. J Bone Joint Surg Am. 1995;77(7):1058\u201364.","journal-title":"J Bone Joint Surg Am"},{"issue":"3","key":"1006_CR38","doi-asserted-by":"publisher","first-page":"155","DOI":"10.1097\/00005131-199903000-00001","volume":"13","author":"JI Kauffman","year":"1999","unstructured":"Kauffman JI, Simon JA, Kummer FJ, et al. Internal fixation of femoral neck fractures with posterior comminution: a biomechanical study. J Orthop Trauma. 1999;13(3):155\u20139.","journal-title":"J Orthop Trauma"},{"key":"1006_CR39","doi-asserted-by":"publisher","first-page":"26","DOI":"10.1186\/1475-925X-6-26","volume":"6","author":"S Yoshioka","year":"2007","unstructured":"Yoshioka S, Nagano A, Himeno R, et al. Computation of the kinematics and the minimum peak joint moments of sit-to-stand movements. Biomed Eng Online. 2007;6:26.","journal-title":"Biomed Eng Online"},{"issue":"7","key":"1006_CR40","doi-asserted-by":"publisher","first-page":"859","DOI":"10.1016\/S0021-9290(01)00040-9","volume":"34","author":"G Bergmann","year":"2001","unstructured":"Bergmann G, Deuretzbacher G, Heller M, et al. Hip contact forces and gait patterns from routine activities. J Biomech. 2001;34(7):859\u201371.","journal-title":"J Biomech"},{"issue":"6","key":"1006_CR41","doi-asserted-by":"publisher","first-page":"340","DOI":"10.1097\/BOT.0b013e3182163345","volume":"25","author":"B Gueorguiev","year":"2011","unstructured":"Gueorguiev B, Ockert B, Schwieger K, et al. Angular stability potentially permits fewer locking screws compared with conventional locking in intramedullary nailed distal tibia fractures: a biomechanical study. J Orthop Trauma. 2011;25(6):340\u20136.","journal-title":"J Orthop Trauma"},{"issue":"3","key":"1006_CR42","doi-asserted-by":"publisher","first-page":"550","DOI":"10.1302\/0301-620X.41B3.550","volume":"41","author":"RA Denham","year":"1959","unstructured":"Denham RA. Hip mechanics. J Bone Joint Surg Br. 1959;41(3):550\u20137.","journal-title":"J Bone Joint Surg Br"},{"issue":"1","key":"1006_CR43","doi-asserted-by":"publisher","first-page":"12","DOI":"10.1097\/00005131-200401000-00003","volume":"18","author":"EN Kubiak","year":"2004","unstructured":"Kubiak EN, Bong M, Park SS, et al. Intramedullary fixation of unstable intertrochanteric hip fractures: one or two lag screws. J Orthop Trauma. 2004;18(1):12\u20137.","journal-title":"J Orthop Trauma"},{"issue":"4","key":"1006_CR44","first-page":"478","volume":"65","author":"JO Laursen","year":"1999","unstructured":"Laursen JO. Treatment of intracapsular fractures of the femoral neck in Denmark: trends in indications over the past decade. Acta Orthop Belg. 1999;65(4):478\u201384.","journal-title":"Acta Orthop Belg"},{"key":"1006_CR45","doi-asserted-by":"publisher","first-page":"85","DOI":"10.1097\/00003086-199106000-00011","volume":"267","author":"ER Springer","year":"1991","unstructured":"Springer ER, Lachiewicz PF, Gilbert JA, et al. Internal fixation of femoral neck fractures. A comparative biomechanical study of knowles pins and 6.5\u00a0mm cancellous screws. Clin Orthop Relat Res. 1991;267:85\u201392.","journal-title":"Clin Orthop Relat Res"},{"issue":"11","key":"1006_CR46","doi-asserted-by":"publisher","first-page":"1889","DOI":"10.1016\/j.injury.2019.07.020","volume":"50","author":"F Kuan","year":"2019","unstructured":"Kuan F, Hsu KL, Lin CL, et al. Biomechanical properties of off-axis screw in pauwels III femoral neck fracture fixation: bicortical screw construct is superior to unicortical screw construct. Injury. 2019;50(11):1889\u201394.","journal-title":"Injury"}],"container-title":["BioMedical Engineering OnLine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12938-022-01006-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12938-022-01006-6\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12938-022-01006-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,6,10]],"date-time":"2022-06-10T16:21:34Z","timestamp":1654878094000},"score":1,"resource":{"primary":{"URL":"https:\/\/biomedical-engineering-online.biomedcentral.com\/articles\/10.1186\/s12938-022-01006-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,6,10]]},"references-count":46,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2022,12]]}},"alternative-id":["1006"],"URL":"https:\/\/doi.org\/10.1186\/s12938-022-01006-6","relation":{},"ISSN":["1475-925X"],"issn-type":[{"value":"1475-925X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,6,10]]},"assertion":[{"value":"7 November 2021","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"26 May 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"10 June 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they have no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"34"}}