{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,2,21]],"date-time":"2025-02-21T11:11:09Z","timestamp":1740136269936,"version":"3.37.3"},"reference-count":20,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2022,9,7]],"date-time":"2022-09-07T00:00:00Z","timestamp":1662508800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,9,7]],"date-time":"2022-09-07T00:00:00Z","timestamp":1662508800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/100019266","name":"Korea Medical Device Development Fund","doi-asserted-by":"publisher","award":["HW20C2151","HW20C2151","HW20C2151","HW20C2151","HW20C2151"],"award-info":[{"award-number":["HW20C2151","HW20C2151","HW20C2151","HW20C2151","HW20C2151"]}],"id":[{"id":"10.13039\/100019266","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BioMed Eng OnLine"],"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>Estimating relative tidal volume is an important factor when monitoring breathing status. The relationship between temperature and respiration volume has rarely been studied. In this paper, a formula was derived for calculating thermodiluted respiration volume from temperature changes in the nasal cavity. To evaluate the proposed formula, the study compared the relative tidal volume estimated by the proposed formula with that recorded by a respiration volume monitor (Exspiron1Xi, RVM). Thermal data were obtained for 8 cases at a rate of 10 measurements per second. Simultaneous recordings by the RVM are regarded as the reference.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>The mean of ICC coefficient is 0.948\u2009\u00b1\u20090.030, RMSE is 0.1026\u2009\u00b1\u20090.0284, R-squared value is 0.8962\u2009\u00b1\u20090.065 and linear regression coefficient <jats:inline-formula><jats:alternatives><jats:tex-math>$$\\mathrm{\\alpha }$$<\/jats:tex-math><mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\">\n                    <mml:mi>\u03b1<\/mml:mi>\n                  <\/mml:math><\/jats:alternatives><\/jats:inline-formula> is 0.966\u2009\u00b1\u20090.104, <jats:inline-formula><jats:alternatives><jats:tex-math>$$\\upbeta$$<\/jats:tex-math><mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\">\n                    <mml:mi>\u03b2<\/mml:mi>\n                  <\/mml:math><\/jats:alternatives><\/jats:inline-formula> is 0.042\u2009\u00b1\u20090.057. Bland\u2013Altman plot showed 96.01% of samples that the difference between the measured and estimated values exists within 2 standard deviations.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusions<\/jats:title>\n                <jats:p>In this paper, a model that can thermodynamically calculate the relationship between thermal energy and respiration volume is proposed. The thermodiluted model is a feasible method for estimating relative respiration tidal volumes.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s12938-022-01028-0","type":"journal-article","created":{"date-parts":[[2022,9,7]],"date-time":"2022-09-07T10:06:37Z","timestamp":1662545197000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Thermodiluted relative tidal volume estimation using a thermal camera in operating room under spinal anesthesia"],"prefix":"10.1186","volume":"21","author":[{"given":"JunHwan","family":"Kwon","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Oyun","family":"Kwon","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"KyeongTeak","family":"Oh","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jeongmin","family":"Kim","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Cheung Soo","family":"Shin","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sun K.","family":"Yoo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2022,9,7]]},"reference":[{"key":"1028_CR1","unstructured":"Braun SR. Respiratory rate and pattern. In: Walker HK, Hall WD, Hurst JW (eds). Clinical methods: the history, physical, and laboratory examinations. 3rd ed Boston: Butterworths; 1990 Chapter 43."},{"key":"1028_CR2","doi-asserted-by":"publisher","first-page":"1625","DOI":"10.1164\/ajrccm\/138.6.1625","volume":"138","author":"MJ Tobin","year":"1988","unstructured":"Tobin MJ. Respiratory monitoring in the intensive care unit. Am Rev Respir Dis. 1988;138:1625\u201342.","journal-title":"Am Rev Respir Dis"},{"key":"1028_CR3","doi-asserted-by":"publisher","first-page":"5","DOI":"10.1183\/09041950.005s1693","volume":"6","author":"PH Quanjer","year":"1993","unstructured":"Quanjer PH, Tammeling GJ, Cotes JE, Pedersen OF, Peslin R, Yernault JC. Lung volumes and forced ventilatory flows. Eur Respir J. 1993;6:5\u201340.","journal-title":"Eur Respir J"},{"key":"1028_CR4","doi-asserted-by":"publisher","first-page":"291","DOI":"10.1513\/AnnalsATS.201807-502CME","volume":"16","author":"JW Kreit","year":"2019","unstructured":"Kreit JW. Volume capnography in the intensive care unit: physiological principles, measurements, and calculations. Ann Am Thorac Soc. 2019;16:291\u2013300.","journal-title":"Ann Am Thorac Soc"},{"key":"1028_CR5","doi-asserted-by":"publisher","first-page":"379","DOI":"10.1213\/01.ANE.0000131964.67524.E7","volume":"99","author":"RG Soto","year":"2004","unstructured":"Soto RG, Fu ES, Vila H, Miguel RV. Capnography accurately detects apnea during monitored anesthesia care. Anesth Analg. 2004;99:379\u201382.","journal-title":"Anesth Analg"},{"key":"1028_CR6","doi-asserted-by":"publisher","first-page":"191","DOI":"10.1109\/TBME.1970.4502733","volume":"BME-17","author":"AS Khalafalla","year":"1970","unstructured":"Khalafalla AS, Stackhouse SP, Schmitt OH. Thoracic impedance gradient with respect to breathing. IEEE Trans Biomed Eng. 1970;BME-17:191\u20138.","journal-title":"IEEE Trans Biomed Eng"},{"key":"1028_CR7","doi-asserted-by":"publisher","first-page":"97","DOI":"10.1016\/j.ijpsycho.2005.02.003","volume":"59","author":"JH Houtveen","year":"2006","unstructured":"Houtveen JH, Groot PFC, de Geus EJC. Validation of the thoracic impedance derived respiratory signal using multilevel analysis. Int J Psychophysiol. 2006;59:97\u2013106.","journal-title":"Int J Psychophysiol"},{"key":"1028_CR8","doi-asserted-by":"publisher","DOI":"10.1117\/3.2588945","volume-title":"Spectral dependence In Common sense approach to thermal imaging","author":"GC Holst","year":"2000","unstructured":"Holst GC. Spectral dependence In Common sense approach to thermal imaging. Washington, DC: SPIE Optical Engineering Press; 2000."},{"key":"1028_CR9","doi-asserted-by":"crossref","unstructured":"Fei J, Pavlidis I. Virtual thermistor. In: 2007 29th annual international conference of the IEEE engineering in medicine and biology society. Lyon: IEEE; 2007. 250\u20133.","DOI":"10.1109\/IEMBS.2007.4352271"},{"key":"1028_CR10","doi-asserted-by":"publisher","first-page":"988","DOI":"10.1109\/TBME.2009.2032415","volume":"57","author":"F Jin","year":"2010","unstructured":"Jin F, Pavlidis I. Thermistor at a distance: unobtrusive measurement of breathing. IEEE Trans Biomed Eng. 2010;57:988\u201398.","journal-title":"IEEE Trans Biomed Eng"},{"key":"1028_CR11","first-page":"4250","volume":"2015","author":"CB Pereira","year":"2015","unstructured":"Pereira CB, Xinchi Y, Blazek V, Leonhardt S. Robust remote monitoring of breathing function by using infrared thermography. In, 37th annual international conference of the IEEE engineering in medicine and biology society (EMBC) Milan, Italy. IEEE. 2015;2015:4250\u20133.","journal-title":"IEEE"},{"key":"1028_CR12","doi-asserted-by":"publisher","first-page":"1105","DOI":"10.1109\/TBME.2018.2866878","volume":"66","author":"CB Pereira","year":"2019","unstructured":"Pereira CB, Yu X, Goos T, Reiss I, Orlikowsky T, Heimann K, et al. Noncontact monitoring of respiratory rate in newborn infants using thermal imaging. IEEE Trans Biomed Eng. 2019;66:1105\u201314.","journal-title":"IEEE Trans Biomed Eng"},{"key":"1028_CR13","doi-asserted-by":"publisher","first-page":"491","DOI":"10.1161\/01.RES.10.3.491","volume":"10","author":"KF Hosie","year":"1962","unstructured":"Hosie KF. Thermal-dilution technics. Circ Res. 1962;10:491\u2013504.","journal-title":"Circ Res"},{"key":"1028_CR14","doi-asserted-by":"publisher","first-page":"731","DOI":"10.1152\/jappl.1954.6.12.731","volume":"6","author":"P Meier","year":"1954","unstructured":"Meier P, Zierler KL. On the theory of the indicator-dilution method for measurement of blood flow and volume. J Appl Physiol. 1954;6:731\u201344.","journal-title":"J Appl Physiol"},{"key":"1028_CR15","doi-asserted-by":"publisher","first-page":"93","DOI":"10.1186\/1475-925X-10-93","volume":"10","author":"AK Abbas","year":"2011","unstructured":"Abbas AK, Heimann K, Jergus K, Orlikowsky T, Leonhardt S. Neonatal non-contact respiratory monitoring based on real-time infrared thermography. Biomed Eng Online. 2011;10:93.","journal-title":"Biomed Eng Online"},{"key":"1028_CR16","unstructured":"Mosby. Mosby's medical dictionary. 9th ed Louis, MO: Elsevier; 2012"},{"key":"1028_CR17","doi-asserted-by":"publisher","first-page":"33","DOI":"10.1007\/s10877-015-9674-y","volume":"30","author":"K Holley","year":"2015","unstructured":"Holley K, MacNabb CM, Georgiadis P, Minasyan H, Shukla A, Mathews D. Monitoring minute ventilation versus respiratory rate to measure the adequacy of ventilation in patients undergoing upper endoscopic procedures. J Clin Monit Comput. 2015;30:33\u20139.","journal-title":"J Clin Monit Comput"},{"key":"1028_CR18","doi-asserted-by":"publisher","first-page":"223","DOI":"10.1007\/s10877-014-9596-0","volume":"29","author":"CJ Voscopoulos","year":"2015","unstructured":"Voscopoulos CJ, MacNabb CM, Brayanov J, Qin L, Freeman J, Mullen GJ, et al. The evaluation of a non-invasive respiratory volume monitor in surgical patients undergoing elective surgery with general anesthesia. J Clin Monit Comput. 2015;29:223\u201330.","journal-title":"J Clin Monit Comput"},{"key":"1028_CR19","doi-asserted-by":"publisher","first-page":"91","DOI":"10.1213\/ANE.0b013e3182918098","volume":"117","author":"C Voscopoulos","year":"2013","unstructured":"Voscopoulos C, Brayanov J, Ladd D, Lalli M, Panasyuk A, Freeman J. Evaluation of a novel noninvasive respiration monitor providing continuous measurement of minute ventilation in ambulatory subjects in a variety of clinical scenarios. Anesth Analg. 2013;117:91\u2013100.","journal-title":"Anesth Analg"},{"key":"1028_CR20","doi-asserted-by":"publisher","first-page":"647","DOI":"10.1007\/s10877-018-0214-4","volume":"33","author":"J Kim","year":"2019","unstructured":"Kim J, Kwon JH, Kim E, Yoo SK, Shin C-S. Respiratory measurement using infrared thermography and respiratory volume monitor during sedation in patients undergoing endoscopic urologic procedures under spinal anesthesia. J Clin Monit Comput. 2019;33:647\u201356.","journal-title":"J Clin Monit Comput"}],"container-title":["BioMedical Engineering OnLine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12938-022-01028-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12938-022-01028-0\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12938-022-01028-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,10,5]],"date-time":"2022-10-05T12:42:04Z","timestamp":1664973724000},"score":1,"resource":{"primary":{"URL":"https:\/\/biomedical-engineering-online.biomedcentral.com\/articles\/10.1186\/s12938-022-01028-0"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,9,7]]},"references-count":20,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2022,12]]}},"alternative-id":["1028"],"URL":"https:\/\/doi.org\/10.1186\/s12938-022-01028-0","relation":{},"ISSN":["1475-925X"],"issn-type":[{"type":"electronic","value":"1475-925X"}],"subject":[],"published":{"date-parts":[[2022,9,7]]},"assertion":[{"value":"3 June 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"24 August 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"7 September 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"All procedures performed in studies involving human participants were in accordance with the ethical standards of the institutional and\/or national research committee and with the 1964 Helsinki declaration and its later amendments or comparable ethical standards.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Informed consent was obtained from all individual participants included in the study.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they have no conflict of interest.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"64"}}