{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,22]],"date-time":"2026-01-22T17:45:28Z","timestamp":1769103928968,"version":"3.49.0"},"reference-count":13,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2023,3,10]],"date-time":"2023-03-10T00:00:00Z","timestamp":1678406400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2023,3,10]],"date-time":"2023-03-10T00:00:00Z","timestamp":1678406400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BioMed Eng OnLine"],"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>Heart auscultation is an easy and inexpensive tool for early diagnosis of congenital heart defects. In this regard, a simple device which can be used easily by physicians for heart murmur detection will be very useful. The current study was conducted to evaluate the validity of a Doppler-based device named \u201cDoppler Phonolyser\u201d for the diagnosis of structural heart diseases in pediatric patients. In this cross-sectional study, 1272 patients under 16 years who were referred between April 2021 and February 2022, to a pediatric cardiology clinic in Mofid Children Hospital, Tehran, Iran, were enrolled. All the patients were examined by a single experienced pediatric cardiologist using a conventional stethoscope at the first step and a Doppler Phonolyser device at the second step. Afterward, the patient underwent trans-thoracic echocardiography, and the echocardiogram results were compared with the conventional stethoscope as well as the Doppler Phonolyser findings.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>Sensitivity of the Doppler Phonolyser for detecting congenital heart defects was 90.5%. The specificity of the Doppler Phonolyser in detecting heart disease was 68.9% in compared with the specificity of the conventional stethoscope, which was 94.8%. Among the most common congenital heart defects in our study population, the sensitivity of the Doppler Phonolyser was 100% for detection of tetralogy of Fallot (TOF); In contrast, sensitivity of both the conventional stethoscope and the Doppler Phonolyser was relatively low for detecting atrial septal defect.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusions<\/jats:title>\n                <jats:p>Doppler Phonolyser could be useful as a diagnostic tool for the detection of congenital heart defects. The main advantages of the Doppler Phonolyser over the conventional stethoscope are no need for operator experience, the ability to distinguish innocent murmurs from the pathologic ones and no effect of environmental sounds on the performance of the device.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s12938-023-01084-0","type":"journal-article","created":{"date-parts":[[2023,3,26]],"date-time":"2023-03-26T20:19:22Z","timestamp":1679861962000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Evaluation of the heart sounds in children using a Doppler Phonolyser"],"prefix":"10.1186","volume":"22","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-6365-2530","authenticated-orcid":false,"given":"Mohammad Reza","family":"Khalilian","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2081-1308","authenticated-orcid":false,"given":"Mahsa","family":"Safari","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8187-9114","authenticated-orcid":false,"given":"Mahmoud","family":"Hajipour","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1734-040X","authenticated-orcid":false,"given":"Khosro","family":"Rahmani","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0289-3722","authenticated-orcid":false,"given":"Mahmoud","family":"Safari","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mohammad Hassan","family":"Ahmadpour","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7554-7770","authenticated-orcid":false,"given":"Tahmineh","family":"Tahouri","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2023,3,10]]},"reference":[{"issue":"4","key":"1084_CR1","first-page":"445","volume":"23","author":"A Kocharian","year":"2013","unstructured":"Kocharian A, Sepehri AA, Janani A, Malakan-Rad E. Efficiency, sensitivity and specificity of automated auscultation diagnosis device for detection and discrimination of cardiac murmurs in children. Iran J Pediatr. 2013;23(4):445\u201350.","journal-title":"Iran J Pediatr"},{"issue":"4","key":"1084_CR2","doi-asserted-by":"publisher","first-page":"1376","DOI":"10.3390\/s21041376","volume":"21","author":"K Takahashi","year":"2021","unstructured":"Takahashi K, Ono K, Arai H, Adachi H, Ito M, Kato A, Takahashi T. Detection of Pathologic Heart Murmurs Using a Piezoelectric Sensor. Sensors (Basel). 2021;21(4):1376. https:\/\/doi.org\/10.3390\/s21041376.","journal-title":"Sensors (Basel)"},{"key":"1084_CR3","doi-asserted-by":"publisher","first-page":"1900312","DOI":"10.1109\/JTEHM.2018.2847329","volume":"6","author":"H Ren","year":"2018","unstructured":"Ren H, Jin H, Chen C, Ghayvat H, Chen W. A novel cardiac auscultation monitoring system based on wireless sensing for healthcare. IEEE J Transl Eng Health Med. 2018;6:1900312. https:\/\/doi.org\/10.1109\/JTEHM.2018.2847329.","journal-title":"IEEE J Transl Eng Health Med"},{"key":"1084_CR4","doi-asserted-by":"publisher","first-page":"29","DOI":"10.2147\/MDER.S135882","volume":"11","author":"S Swarup","year":"2018","unstructured":"Swarup S, Makaryus AN. Digital stethoscope: technology update. Med Devices (Auckl). 2018;11:29\u201336. https:\/\/doi.org\/10.2147\/MDER.S135882.","journal-title":"Med Devices (Auckl)"},{"issue":"1","key":"1084_CR5","first-page":"1","volume":"5","author":"AF G\u00fcnd\u00fcz","year":"2022","unstructured":"G\u00fcnd\u00fcz AF, Karci A. Heart sound classification for murmur abnormality detection using an ensemble approach based on traditional classifiers and feature sets. Computer Sci. 2022;5(1):1\u201313.","journal-title":"Computer Sci"},{"issue":"2","key":"1084_CR6","doi-asserted-by":"publisher","first-page":"e49","DOI":"10.2196\/mhealth.8946","volume":"6","author":"SH Kang","year":"2018","unstructured":"Kang SH, Joe B, Yoon Y, Cho GY, Shin I, Suh JW. Cardiac Auscultation Using Smartphones: Pilot Study. Mhealth Uhealth. 2018;6(2):e49. https:\/\/doi.org\/10.2196\/mhealth.8946.","journal-title":"Mhealth Uhealth"},{"issue":"21","key":"1084_CR7","doi-asserted-by":"publisher","first-page":"5867","DOI":"10.1126\/sciadv.abo5867","volume":"8","author":"SH Lee","year":"2022","unstructured":"Lee SH, Kim YS, Yeo MK, Mahmood M, Zavanelli N, Chung C, Heo JY, Kim Y, Jung SS, Yeo WH. Fully portable continuous real-time auscultation with a soft wearable stethoscope designed for automated disease diagnosis. Sci Adv. 2022;8(21):5867. https:\/\/doi.org\/10.1126\/sciadv.abo5867.","journal-title":"Sci Adv"},{"issue":"5","key":"1084_CR8","doi-asserted-by":"publisher","first-page":"373","DOI":"10.1007\/s002460010253","volume":"22","author":"WR Thompson","year":"2001","unstructured":"Thompson WR, Hayek CS, Tuchinda C, Telford JK, Lombardo JS. Automated cardiac auscultation for detection of pathologic heart murmurs. Pediatr Cardiol. 2001;22(5):373\u20139. https:\/\/doi.org\/10.1007\/s002460010253.","journal-title":"Pediatr Cardiol"},{"key":"1084_CR9","doi-asserted-by":"publisher","first-page":"9640821","DOI":"10.1155\/2020\/9640821","volume":"2020","author":"J Wang","year":"2020","unstructured":"Wang J, You T, Yi K, Gong Y, Xie Q, Qu F, Wang B, He Z. Intelligent Diagnosis of heart murmurs in children with congenital heart Disease. J Healthc Eng. 2020;2020:9640821. https:\/\/doi.org\/10.1155\/2020\/9640821.","journal-title":"J Healthc Eng"},{"issue":"2","key":"1084_CR10","doi-asserted-by":"publisher","first-page":"244","DOI":"10.1109\/TBME.2006.886660","volume":"54","author":"JP de Vos","year":"2007","unstructured":"de Vos JP, Blanckenberg MM. Automated pediatric cardiac auscultation. IEEE Trans Biomed Eng. 2007;54(2):244\u201352. https:\/\/doi.org\/10.1109\/TBME.2006.886660.","journal-title":"IEEE Trans Biomed Eng"},{"issue":"6","key":"1084_CR11","doi-asserted-by":"publisher","first-page":"307","DOI":"10.3109\/03091902.2014.921253","volume":"38","author":"DA Kelmenson","year":"2014","unstructured":"Kelmenson DA, Heath JK, Ball SA, Kaafarani HM, Baker EM, Yeh DD, Bittner EA, Eikermann M, Lee J. Prototype electronic stethoscope vs conventional stethoscope for auscultation of heart sounds. J Med Eng Technol. 2014;38(6):307\u201310. https:\/\/doi.org\/10.3109\/03091902.2014.921253.","journal-title":"J Med Eng Technol"},{"issue":"1","key":"1084_CR12","doi-asserted-by":"publisher","first-page":"11551","DOI":"10.1038\/s41598-018-29984-5","volume":"8","author":"C Will","year":"2018","unstructured":"Will C, Shi K, Schellenberger S, Steigleder T, Michler F, Fuchs J, Weigel R, Ostgathe C, Koelpin A. Radar-based heart sound detection. Sci Rep. 2018;8(1):11551. https:\/\/doi.org\/10.1038\/s41598-018-29984-5.","journal-title":"Sci Rep"},{"issue":"2","key":"1084_CR13","first-page":"558","volume":"60","author":"ME McConnell","year":"1999","unstructured":"McConnell ME, Adkins SB 3rd, Hannon DW. Heart murmurs in pediatric patients: when do you refer? Am Fam Physician. 1999;60(2):558\u201365.","journal-title":"Am Fam Physician"}],"container-title":["BioMedical Engineering OnLine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12938-023-01084-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12938-023-01084-0\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12938-023-01084-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,3,26]],"date-time":"2023-03-26T20:21:18Z","timestamp":1679862078000},"score":1,"resource":{"primary":{"URL":"https:\/\/biomedical-engineering-online.biomedcentral.com\/articles\/10.1186\/s12938-023-01084-0"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,3,10]]},"references-count":13,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2023,12]]}},"alternative-id":["1084"],"URL":"https:\/\/doi.org\/10.1186\/s12938-023-01084-0","relation":{},"ISSN":["1475-925X"],"issn-type":[{"value":"1475-925X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,3,10]]},"assertion":[{"value":"15 September 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"21 February 2023","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"10 March 2023","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The ethics committee of Shahid Beheshti University of Medical Science approved the study protocol by reference number of IR.SBMU.MSP.REC.1400.641. Informed consent was obtained from the parent of the child to participate in this research. The consent form is available upon request.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Informed consent was obtained from the parents of the children to publish this article. The consent form is available upon request.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors certify that they have no affiliations with or involvement in any organization or entity with any financial interest (such as honoraria, educational grants, participation in speakers\u2019 bureaus; membership, employment, consultancies, stock ownership, or other equity interest; and expert testimony or patent-licensing arrangements), or non-financial interest (such as personal or professional relationships, affiliations, knowledge or beliefs) in the subject matter or materials discussed in this manuscript.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"24"}}