{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,23]],"date-time":"2026-07-23T15:33:24Z","timestamp":1784820804806,"version":"3.55.0"},"reference-count":49,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,2,27]],"date-time":"2025-02-27T00:00:00Z","timestamp":1740614400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2025,2,27]],"date-time":"2025-02-27T00:00:00Z","timestamp":1740614400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"funder":[{"name":"Natural Science Foundation of Guangdong Province, China","award":["2021A1515011822"],"award-info":[{"award-number":["2021A1515011822"]}]},{"name":"Natural Science Foundation of Guangdong Province, China","award":["2021A1515011822"],"award-info":[{"award-number":["2021A1515011822"]}]},{"name":"Natural Science Foundation of Guangdong Province, China","award":["2021A1515011822"],"award-info":[{"award-number":["2021A1515011822"]}]},{"name":"Natural Science Foundation of Guangdong Province, China","award":["2021A1515011822"],"award-info":[{"award-number":["2021A1515011822"]}]},{"name":"Natural Science Foundation of Guangdong Province, China","award":["2021A1515011822"],"award-info":[{"award-number":["2021A1515011822"]}]},{"name":"Natural Science Foundation of Guangdong Province, China","award":["2021A1515011822"],"award-info":[{"award-number":["2021A1515011822"]}]},{"name":"Natural Science Foundation of Guangdong Province, China","award":["2021A1515011822"],"award-info":[{"award-number":["2021A1515011822"]}]},{"name":"Natural Science Foundation of Guangdong Province, China","award":["2021A1515011822"],"award-info":[{"award-number":["2021A1515011822"]}]},{"name":"Medical Scientific Research Foundation of Guangdong Province, China","award":["A2019231& B2019101"],"award-info":[{"award-number":["A2019231& B2019101"]}]},{"name":"Medical Scientific Research Foundation of Guangdong Province, China","award":["A2019231& B2019101"],"award-info":[{"award-number":["A2019231& B2019101"]}]},{"name":"Medical Scientific Research Foundation of Guangdong Province, China","award":["A2019231& B2019101"],"award-info":[{"award-number":["A2019231& B2019101"]}]},{"name":"Medical Scientific Research Foundation of Guangdong Province, China","award":["A2019231& B2019101"],"award-info":[{"award-number":["A2019231& B2019101"]}]},{"name":"Medical Scientific Research Foundation of Guangdong Province, China","award":["A2019231& B2019101"],"award-info":[{"award-number":["A2019231& B2019101"]}]},{"name":"Medical Scientific Research Foundation of Guangdong Province, China","award":["A2019231& B2019101"],"award-info":[{"award-number":["A2019231& B2019101"]}]},{"name":"Medical Scientific Research Foundation of Guangdong Province, China","award":["A2019231& B2019101"],"award-info":[{"award-number":["A2019231& B2019101"]}]},{"name":"Medical Scientific Research Foundation of Guangdong Province, China","award":["A2019231& B2019101"],"award-info":[{"award-number":["A2019231& B2019101"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BioMed Eng OnLine"],"DOI":"10.1186\/s12938-025-01343-2","type":"journal-article","created":{"date-parts":[[2025,2,28]],"date-time":"2025-02-28T07:47:29Z","timestamp":1740728849000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["A novel corneal indentation device for comparison of corneal tangent modulus before and after FS-LASIK in vivo"],"prefix":"10.1186","volume":"24","author":[{"given":"Yan","family":"Zhang","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Junyu","family":"Lin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shu-Hao","family":"Lu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jones Iok-Tong","family":"Chong","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Cheng","family":"Yang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jianqing","family":"Lan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wenjuan","family":"Xie","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Juan","family":"Li","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David Chuen-Chun","family":"Lam","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dan","family":"Cao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jin","family":"Zeng","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,2,27]]},"reference":[{"key":"1343_CR1","doi-asserted-by":"publisher","first-page":"65","DOI":"10.1016\/j.ajo.2017.03.013","volume":"178","author":"D Wen","year":"2017","unstructured":"Wen D, McAlinden C, Flitcroft I, et al. Postoperative efficacy, predictability, safety, and visual quality of laser corneal refractive surgery: a network meta-analysis. Am J Ophthalmol. 2017;178:65\u201378.","journal-title":"Am J Ophthalmol"},{"key":"1343_CR2","doi-asserted-by":"publisher","first-page":"28","DOI":"10.1136\/bjophthalmol-2015-306770","volume":"100","author":"L Spadea","year":"2016","unstructured":"Spadea L, Giammaria D, Trabucco P. Corneal wound healing after laser vision correction. Br J Ophthalmol. 2016;100:28\u201333.","journal-title":"Br J Ophthalmol"},{"issue":"4","key":"1343_CR3","doi-asserted-by":"publisher","first-page":"388","DOI":"10.1097\/01.ico.0000222479.68242.77","volume":"25","author":"SR Klein","year":"2006","unstructured":"Klein SR, Epstein RJ, Randleman JB, et al. Corneal ectasia after laser in situ keratomileusis in patients without apparent preoperative risk factors. Cornea. 2006;25(4):388\u2013403.","journal-title":"Cornea"},{"key":"1343_CR4","doi-asserted-by":"publisher","first-page":"875","DOI":"10.3928\/1081597X-20090917-09","volume":"25","author":"AS Roy","year":"2009","unstructured":"Roy AS, Dupps WJ. Effects of altered corneal stiffness on native and postoperative LASIK corneal biomechanical behavior: a whole-eye finite element analysis. J Refract Surg. 2009;25:875\u201387.","journal-title":"J Refract Surg"},{"issue":"1","key":"1343_CR5","doi-asserted-by":"publisher","first-page":"156","DOI":"10.1016\/j.jcrs.2004.10.044","volume":"31","author":"DA Luce","year":"2005","unstructured":"Luce DA. Determining in vivo biomechanical properties of the cornea with an ocular response analyzer. J Cataract Refract Surg. 2005;31(1):156\u201362.","journal-title":"J Cataract Refract Surg"},{"issue":"2","key":"1343_CR6","doi-asserted-by":"publisher","first-page":"127","DOI":"10.1111\/aos.13906","volume":"97","author":"P Raevdal","year":"2019","unstructured":"Raevdal P, Grauslund J, Vestergaard AH. Comparison of corneal biomechanical changes after refractive surgery by noncontact tonometry: small-incision lenticule extraction versus flap-based refractive surgery - a systematic review. Acta Ophthalmol. 2019;97(2):127\u201336.","journal-title":"Acta Ophthalmol"},{"issue":"6","key":"1343_CR7","doi-asserted-by":"publisher","first-page":"862","DOI":"10.1016\/j.jcrs.2014.04.019","volume":"40","author":"CJ Roberts","year":"2014","unstructured":"Roberts CJ. Concepts and misconceptions in corneal biomechanics. J Cart Refract Surg. 2014;40(6):862\u20139.","journal-title":"J Cart Refract Surg"},{"issue":"7","key":"1343_CR8","doi-asserted-by":"publisher","first-page":"553","DOI":"10.3109\/02713683.2012.669007","volume":"37","author":"N Terai","year":"2012","unstructured":"Terai N, Raiskup F, Haustein M, et al. Identification of biomechanical properties of the cornea: the ocular response analyzer. Curr Eye Res. 2012;37(7):553\u201362.","journal-title":"Curr Eye Res"},{"issue":"6","key":"1343_CR9","doi-asserted-by":"publisher","first-page":"445","DOI":"10.1097\/OPX.0b013e3181783a70","volume":"85","author":"KE Hamilton","year":"2008","unstructured":"Hamilton KE, Pye DC. Young \u2019 s modulus in normal corneas and the effect on applanation tonometry. Optom Vis Sci. 2008;85(6):445\u201350.","journal-title":"Optom Vis Sci"},{"issue":"3","key":"1343_CR10","doi-asserted-by":"publisher","first-page":"155","DOI":"10.1089\/ten.teb.2010.0520","volume":"17","author":"CT McKee","year":"2011","unstructured":"McKee CT, Last JA, Russell P, et al. Indentation versus tensile measurements of Young\u2019s modulus for soft biological tissues. Tissue Eng Part B Rev. 2011;17(3):155\u201364.","journal-title":"Tissue Eng Part B Rev"},{"issue":"4","key":"1343_CR11","first-page":"251","volume":"9","author":"MW Ko","year":"2012","unstructured":"Ko MW, Leung LK, Lam DC. Partial contact indentation tonometry for measurement of corneal properties-independent intraocular pressure. Mol Cell Biomech. 2012;9(4):251\u201368.","journal-title":"Mol Cell Biomech"},{"issue":"9","key":"1343_CR12","doi-asserted-by":"publisher","first-page":"1115","DOI":"10.1016\/j.medengphy.2014.06.003","volume":"36","author":"MWL Ko","year":"2014","unstructured":"Ko MWL, Leung LKK, Lam DCC. Comparative study of corneal tangent elastic modulus measurement using corneal indentation device. Med Eng Phys. 2014;36(9):1115\u201321.","journal-title":"Med Eng Phys"},{"issue":"4","key":"1343_CR13","doi-asserted-by":"publisher","first-page":"e263","DOI":"10.1111\/aos.12066","volume":"91","author":"MW Ko","year":"2013","unstructured":"Ko MW, Leung LK, Lam DC, et al. Characterization of corneal tangent modulus in vivo. Acta Ophthalmol. 2013;91(4):e263\u20139.","journal-title":"Acta Ophthalmol"},{"issue":"4","key":"1343_CR14","doi-asserted-by":"publisher","first-page":"455","DOI":"10.1111\/opo.12219","volume":"35","author":"AK Lam","year":"2015","unstructured":"Lam AK, Hon Y, Leung LK, et al. Repeatability of a novel corneal indentation device for corneal biomechanical measurement. Ophthalmic Physiol Opt. 2015;35(4):455\u201361.","journal-title":"Ophthalmic Physiol Opt"},{"issue":"1","key":"1343_CR15","doi-asserted-by":"publisher","first-page":"20","DOI":"10.1186\/s12938-017-0311-5","volume":"16","author":"X Wang","year":"2017","unstructured":"Wang X, Li X, Chen W, et al. Effects of ablation depth and repair time on the corneal elastic modulus after laser in situ keratomileusis. Biomed Eng Online. 2017;16(1):20.","journal-title":"Biomed Eng Online"},{"issue":"1","key":"1343_CR16","doi-asserted-by":"publisher","first-page":"32","DOI":"10.1016\/j.ajo.2014.03.018","volume":"158","author":"PR Ruise\u00f1or V\u00e1zquez","year":"2014","unstructured":"Ruise\u00f1or V\u00e1zquez PR, Galletti JD, Minguez N, et al. Pentacam Scheimpflug tomography findings in topographically normal patients and subclinical keratoconus cases. Am J Ophthalmol. 2014;158(1):32-40.e2.","journal-title":"Am J Ophthalmol"},{"issue":"2","key":"1343_CR17","doi-asserted-by":"publisher","first-page":"136","DOI":"10.1016\/j.zemedi.2015.11.001","volume":"26","author":"BT Lopes","year":"2016","unstructured":"Lopes BT, Ramos IC, Dawson DG, et al. Detection of ectatic corneal diseases based on pentacam. Z Med Phys. 2016;26(2):136\u201342.","journal-title":"Z Med Phys"},{"issue":"10","key":"1343_CR18","doi-asserted-by":"publisher","first-page":"753","DOI":"10.3928\/1081597X-20110721-01","volume":"27","author":"R Ambr\u00f3sio Jr","year":"2011","unstructured":"Ambr\u00f3sio R Jr, Caiado AL, Guerra FP, et al. Novel pachymetric parameters based on corneal tomography for diagnosing keratoconus. J Refract Surg. 2011;27(10):753\u20138.","journal-title":"J Refract Surg"},{"issue":"1","key":"1343_CR19","doi-asserted-by":"publisher","first-page":"28","DOI":"10.1007\/s40135-012-0003-z","volume":"1","author":"R Ambr\u00f3sio Jr","year":"2013","unstructured":"Ambr\u00f3sio R Jr, Faria-Correia F, Ramos I, et al. Enhanced screening for ectasia susceptibility among refractive candidates: the role of corneal tomography and biomechanics. Current Ophthalmology Reports. 2013;1(1):28\u201338.","journal-title":"Current Ophthalmology Reports"},{"issue":"1","key":"1343_CR20","doi-asserted-by":"publisher","first-page":"225","DOI":"10.1186\/s12886-019-1236-5","volume":"19","author":"M Chen","year":"2019","unstructured":"Chen M, Zhang L, Xu J, et al. Comparability of three intraocular pressure measurements: iCare pro rebound, non-contact, and Goldmann applanation tonometry in different IOP groups. BMC Ophthalmol. 2019;19(1):225.","journal-title":"BMC Ophthalmol"},{"issue":"1","key":"1343_CR21","doi-asserted-by":"publisher","first-page":"233","DOI":"10.1186\/s12886-018-0900-5","volume":"18","author":"M Lanza","year":"2018","unstructured":"Lanza M, Rinaldi M, Carnevale UAG, et al. Analysis of differences in intraocular pressure evaluation performed with contact and non-contact devices. BMC Ophthalmol. 2018;18(1):233.","journal-title":"BMC Ophthalmol"},{"key":"1343_CR22","volume-title":"Roark \u2019 s formulas for stress and strain","author":"WC Young","year":"1989","unstructured":"Young WC, Budynas RG. Roark \u2019 s formulas for stress and strain. New York: McGraw-Hill Book Co; 1989."},{"issue":"1","key":"1343_CR23","doi-asserted-by":"publisher","first-page":"9","DOI":"10.1097\/ICO.0b013e31826ab0a7","volume":"31","author":"DT Azar","year":"2012","unstructured":"Azar DT, Chang JH, Han KY. Wound healing after keratorefractive surgery: review of biological and optical considerations. Cornea. 2012;31(1):9\u201319.","journal-title":"Cornea"},{"issue":"7\u20138","key":"1343_CR24","doi-asserted-by":"publisher","first-page":"869","DOI":"10.1080\/08820538.2018.1539183","volume":"33","author":"M Bohac","year":"2018","unstructured":"Bohac M, Koncarevic M, Pasalic A, et al. Incidence and clinical characteristics of post LASIK ectasia: a review of over 30,000 LASIK cases. Semin Ophthalmol. 2018;33(7\u20138):869\u201377.","journal-title":"Semin Ophthalmol"},{"issue":"3","key":"1343_CR25","doi-asserted-by":"publisher","first-page":"262","DOI":"10.1016\/j.joco.2019.02.002","volume":"31","author":"R Salouti","year":"2019","unstructured":"Salouti R, Khalili MR, Zamani M, et al. Assessment of the changes in corneal biomechanical properties after collagen cross-linking in patients with keratoconus. J Curr Ophthalmol. 2019;31(3):262\u20137.","journal-title":"J Curr Ophthalmol"},{"key":"1343_CR26","doi-asserted-by":"publisher","DOI":"10.1016\/j.medntd.2021.100073","volume":"11","author":"BT Lopes","year":"2021","unstructured":"Lopes BT, Bao FJ, Wang JJ, et al. Review of in-vivo characterisation of corneal biomechanics. Med Novel Technol Dev. 2021;11: 100073.","journal-title":"Med Novel Technol Dev"},{"key":"1343_CR27","doi-asserted-by":"publisher","DOI":"10.3389\/fmed.2021.695697","volume":"8","author":"J Shang","year":"2021","unstructured":"Shang J, Shen Y, Jhanji V, et al. Comparison of corneal biomechanics in post-SMILE, Post-LASEK, and Keratoconic Eyes. Front Med (Lausanne). 2021;8: 695697.","journal-title":"Front Med (Lausanne)"},{"issue":"7","key":"1343_CR28","doi-asserted-by":"publisher","first-page":"967","DOI":"10.1097\/j.jcrs.0000000000000204","volume":"46","author":"S Chen","year":"2020","unstructured":"Chen S, Lopes BT, Huang W, et al. Effectiveness of 4 tonometers in measuring IOP after femtosecond laser-assisted LASIK, SMILE, and transepithelial photorefractive keratectomy. J Cataract Refract Surg. 2020;46(7):967\u201374.","journal-title":"J Cataract Refract Surg"},{"key":"1343_CR29","doi-asserted-by":"publisher","first-page":"740","DOI":"10.3389\/fphys.2019.00740","volume":"10","author":"Y Zhao","year":"2019","unstructured":"Zhao Y, Shen Y, Yan Z, et al. Relationship among corneal stiffness, thickness, and biomechanical parameters measured by Corvis ST, pentacam and ORA in keratoconus. Front Physiol. 2019;10:740.","journal-title":"Front Physiol"},{"key":"1343_CR30","doi-asserted-by":"publisher","first-page":"2367","DOI":"10.1016\/j.jbiomech.2006.12.001","volume":"40","author":"BL Boyce","year":"2007","unstructured":"Boyce BL, Jones RE, Nguyen TD, et al. Stress-controlled viscoelastic tensile response of bovine cornea. J Biomech. 2007;40:2367\u201376.","journal-title":"J Biomech"},{"key":"1343_CR31","doi-asserted-by":"publisher","first-page":"783","DOI":"10.1016\/j.exer.2008.02.006","volume":"86","author":"A Elsheikh","year":"2008","unstructured":"Elsheikh A, Alhasso D, Rama P. Biomechanical properties of human and porcine corneas. Exp Eye Res. 2008;86:783\u201390.","journal-title":"Exp Eye Res"},{"key":"1343_CR32","doi-asserted-by":"publisher","first-page":"551","DOI":"10.1006\/bulm.1999.0102","volume":"61","author":"GJ Orssengo","year":"1999","unstructured":"Orssengo GJ, Pye DC. Determination of the true intraocular pressure and modulus of elasticity of the human cornea in vivo. Bull Math Biol. 1999;61:551\u201372.","journal-title":"Bull Math Biol"},{"key":"1343_CR33","doi-asserted-by":"publisher","first-page":"240","DOI":"10.1111\/opo.12345","volume":"37","author":"S Kling","year":"2017","unstructured":"Kling S, Hafezi F. Corneal biomechanics \u2013 a review. Ophthalmic Physiol Opt. 2017;37:240\u201352.","journal-title":"Ophthalmic Physiol Opt"},{"key":"1343_CR34","doi-asserted-by":"publisher","first-page":"123","DOI":"10.1186\/s12886-016-0304-3","volume":"16","author":"IM Osman","year":"2016","unstructured":"Osman IM, Helaly HA, Abdalla M, et al. 2016 Corneal biomechanical changes in eyes with small incision lenticule extraction and laser assisted in situ keratomileusis. BMC Ophthalmol. 2016;16:123. https:\/\/doi.org\/10.1186\/s12886-016-0304-3.","journal-title":"BMC Ophthalmol"},{"issue":"1","key":"1343_CR35","doi-asserted-by":"publisher","first-page":"39","DOI":"10.1016\/j.ajo.2006.09.036","volume":"143","author":"JS Pepose","year":"2007","unstructured":"Pepose JS, Feigenbaum SK, Qazi MA, et al. Changes in corneal biomechanics and intraocular pressure following LASIK using static, dynamic, and noncontact tonometry. Am J Ophthalmol. 2007;143(1):39\u201348.","journal-title":"Am J Ophthalmol"},{"issue":"3","key":"1343_CR36","doi-asserted-by":"publisher","first-page":"175","DOI":"10.1016\/j.joco.2017.05.002","volume":"29","author":"R Elham","year":"2017","unstructured":"Elham R, Jafarzadehpur E, Hashemi H, et al. Keratoconus diagnosis using Corvis ST measured biomechanical parameters. J Curr Ophthalmol. 2017;29(3):175\u201381.","journal-title":"J Curr Ophthalmol"},{"issue":"4","key":"1343_CR37","doi-asserted-by":"publisher","first-page":"409","DOI":"10.4103\/joco.joco_177_21","volume":"34","author":"A Hamid","year":"2023","unstructured":"Hamid A, Jahadi-Hosseini H, Khalili MR, et al. Corneal biomechanical changes after corneal cross-linking in patients with keratoconus. J Curr Ophthalmol. 2023;34(4):409\u201313.","journal-title":"J Curr Ophthalmol"},{"issue":"1","key":"1343_CR38","doi-asserted-by":"publisher","first-page":"2","DOI":"10.1186\/s40662-023-00371-0","volume":"11","author":"PT Yuhas","year":"2024","unstructured":"Yuhas PT, Fortman MM, Mahmoud AM, Roberts CJ. Keratoconus cone location influences ocular biomechanical parameters measured by the ocular response analyzer. Eye Vis (Lond). 2024;11(1):2.","journal-title":"Eye Vis (Lond)"},{"key":"1343_CR39","doi-asserted-by":"publisher","first-page":"131","DOI":"10.1016\/j.ajo.2022.06.014","volume":"242","author":"Y Xu","year":"2022","unstructured":"Xu Y, Ye Y, Chen Z, et al. Corneal stiffness and modulus of normal-tension glaucoma in Chinese. Am J Ophthalmol. 2022;242:131\u20138.","journal-title":"Am J Ophthalmol"},{"issue":"9","key":"1343_CR40","doi-asserted-by":"publisher","first-page":"36","DOI":"10.1167\/tvst.10.9.36","volume":"10","author":"Y Xu","year":"2021","unstructured":"Xu Y, Ye Y, Chong IT, et al. A novel indentation assessment to measure corneal biomechanical properties in glaucoma and ocular hypertension. Transl Vis Sci Technol. 2021;10(9):36.","journal-title":"Transl Vis Sci Technol"},{"key":"1343_CR41","doi-asserted-by":"publisher","first-page":"43","DOI":"10.1016\/j.exer.2015.12.006","volume":"146","author":"PN Lewis","year":"2016","unstructured":"Lewis PN, White TL, Young RD, et al. Three-dimensional arrangement of elastic fibers in the human corneal. Exp Eye Res. 2016;146:43\u201353.","journal-title":"Exp Eye Res"},{"key":"1343_CR42","doi-asserted-by":"publisher","first-page":"285","DOI":"10.1097\/ICU.0000000000000282","volume":"27","author":"CJ Roberts","year":"2016","unstructured":"Roberts CJ. Importance of accurately assessing biomechanics of the cornea. Curr Opin Ophthalmol. 2016;27:285\u201391.","journal-title":"Curr Opin Ophthalmol"},{"issue":"6","key":"1343_CR43","doi-asserted-by":"publisher","first-page":"658","DOI":"10.3928\/1081-597X-20011101-05","volume":"17","author":"WJ Dupps Jr","year":"2001","unstructured":"Dupps WJ Jr, Roberts C. Effect of acute biomechanical changes on corneal curvature after photokeratectomy. J Refract Surg. 2001;17(6):658\u201369.","journal-title":"J Refract Surg"},{"key":"1343_CR44","doi-asserted-by":"publisher","first-page":"1165","DOI":"10.1053\/apmr.2002.33985","volume":"83","author":"JR Basford","year":"2002","unstructured":"Basford JR. The law of laplace and its relevance to contemporary medicine and rehabilitation. Arch Phys Med Rehabil. 2002;83:1165\u201370.","journal-title":"Arch Phys Med Rehabil"},{"issue":"6","key":"1343_CR45","first-page":"1315","volume":"6","author":"X Fang","year":"2006","unstructured":"Fang X, Xu Y. Corneal stress-strain relation and structural equation of porcine eye after LASIK. Int J Ophthalmol. 2006;6(6):1315\u20139.","journal-title":"Int J Ophthalmol"},{"issue":"5","key":"1343_CR46","doi-asserted-by":"publisher","first-page":"509","DOI":"10.1097\/01.ico.0000151544.23360.17","volume":"24","author":"MV Netto","year":"2005","unstructured":"Netto MV, Mohan RR, Ambr\u00f3sio R Jr, et al. Wound healing in the cornea: a review of refractive surgery complications and new prospects for therapy. Cornea. 2005;24(5):509\u201322.","journal-title":"Cornea"},{"issue":"2","key":"1343_CR47","doi-asserted-by":"publisher","first-page":"118","DOI":"10.3928\/1081597X-20160105-02","volume":"32","author":"A Santhanam","year":"2016","unstructured":"Santhanam A, Wilson SE. Corneal molecular and cellular biology for the refractive surgeon: the critical role of the epithelial basement membrane. J Refract Surg. 2016;32(2):118\u201325.","journal-title":"J Refract Surg"},{"key":"1343_CR48","doi-asserted-by":"publisher","first-page":"337","DOI":"10.1097\/ICU.0000000000000383","volume":"28","author":"P Giri","year":"2017","unstructured":"Giri P, Azar DT. Risk profiles of ectasia after keratorefractive surgery. Curr Opin Ophthalmol. 2017;28:337\u201342.","journal-title":"Curr Opin Ophthalmol"},{"issue":"1","key":"1343_CR49","doi-asserted-by":"publisher","first-page":"14974","DOI":"10.1038\/s41598-017-14750-w","volume":"7","author":"Y Hon","year":"2017","unstructured":"Hon Y, Chen GZ, Lu SH, Lam DC, Lam AK. In vivo measurement of regional corneal tangent modulus. Sci Rep. 2017;7(1):14974.","journal-title":"Sci Rep"}],"container-title":["BioMedical Engineering OnLine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12938-025-01343-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12938-025-01343-2\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12938-025-01343-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,2,28]],"date-time":"2025-02-28T07:47:51Z","timestamp":1740728871000},"score":1,"resource":{"primary":{"URL":"https:\/\/biomedical-engineering-online.biomedcentral.com\/articles\/10.1186\/s12938-025-01343-2"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,2,27]]},"references-count":49,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["1343"],"URL":"https:\/\/doi.org\/10.1186\/s12938-025-01343-2","relation":{"has-preprint":[{"id-type":"doi","id":"10.21203\/rs.3.rs-4146419\/v1","asserted-by":"object"}]},"ISSN":["1475-925X"],"issn-type":[{"value":"1475-925X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,2,27]]},"assertion":[{"value":"22 March 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"24 January 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"27 February 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The research protocols were approved by the Institutional Review Board at Guangdong Provincial People\u2019s Hospital (No. GDREC2017206H(R2)). The study followed the tenets of the Declaration of Helsinki, and all subjects were thoroughly informed of the procedure and provided written informed consent.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"26"}}