{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,23]],"date-time":"2026-10-23T20:41:23Z","timestamp":1792788083615,"version":"4.5.0"},"reference-count":94,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,10,7]],"date-time":"2026-10-07T00:00:00Z","timestamp":1791331200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,10,7]],"date-time":"2026-10-07T00:00:00Z","timestamp":1791331200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Bogazici University Research Fund","award":["19661"],"award-info":[{"award-number":["19661"]}],"id":[{"id":"https:\/\/ror.org\/03z9tma90","id-type":"ROR","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["BioMed Eng OnLine"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>\n                      <jats:bold>Purpose<\/jats:bold>\n                    <\/jats:title>\n                    <jats:p>Magnetic hyperthermia (MH) is a promising localized cancer therapy based on magnetic nanoparticle (MNP)-mediated heating. Although research has extensively focused on MNP development, therapeutic efficacy and safety also depend critically on the engineering of the induction system. This review aims to provide an engineering-focused analysis of contemporary MH instrumentation and its design trade-offs.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>\n                      <jats:bold>Methods<\/jats:bold>\n                    <\/jats:title>\n                    <jats:p>The instrumentation architecture is examined through a dual-domain evaluation of the power electronic and electromagnetic design chain. RF generator architectures are analyzed across the DC supply, oscillator, amplifier, and impedance matching stages. RF coil designs are evaluated according to geometry, inductance, and cooling strategies. An ordinal scoring framework is used to compare representative implementations and assess the influence of architectural choices on energy delivery and thermal stability, providing a structured basis for relative comparison rather than a definitive performance ranking.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>\n                      <jats:bold>Results<\/jats:bold>\n                    <\/jats:title>\n                    <jats:p>The analysis demonstrates that MNP performance is fundamentally constrained by the magnetic field generated by the complete instrumentation chain. Power-stage stability, impedance matching, coil characteristics, cooling, and spatial field homogeneity collectively determine the achievable operating conditions.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>\n                      <jats:bold>Conclusion<\/jats:bold>\n                    <\/jats:title>\n                    <jats:p>Reliable MH requires system-level optimization rather than isolated MNP development. By clarifying key hardware trade-offs and their effects on field generation, this review supports the design of more standardized and reproducible MH induction systems.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s12938-026-01633-3","type":"journal-article","created":{"date-parts":[[2026,10,7]],"date-time":"2026-10-07T09:06:27Z","timestamp":1791363987000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["System-level design trade-offs in magnetic hyperthermia RF instrumentation: a power electronics and electromagnetic design review"],"prefix":"10.1186","volume":"25","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-9262-8249","authenticated-orcid":false,"given":"Serhat Ilgaz","family":"Y\u00f6ner","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alpay","family":"\u00d6zcan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,10,7]]},"reference":[{"issue":"6","key":"1633_CR1","doi-asserted-by":"publisher","first-page":"1156","DOI":"10.3390\/cancers16061156","volume":"16","author":"M Szwed","year":"2024","unstructured":"Szwed M, Marczak A. Application of nanoparticles for magnetic hyperthermia for cancer treatment the current state of knowledge. Cancers. 2024;16(6):1156. https:\/\/doi.org\/10.3390\/cancers16061156.","journal-title":"Cancers"},{"issue":"4","key":"1633_CR2","doi-asserted-by":"publisher","first-page":"596","DOI":"10.1097\/00000658-195710000-00007","volume":"146","author":"RK Gilchrist","year":"1957","unstructured":"Gilchrist RK, Medal R, Shorey WD, Hanselman RC, Parrott JC, Taylor CB. Selective inductive heating of lymph nodes. Ann Surg. 1957;146(4):596\u2013606. https:\/\/doi.org\/10.1097\/00000658-195710000-00007.","journal-title":"Ann Surg"},{"issue":"2","key":"1633_CR3","doi-asserted-by":"publisher","first-page":"26","DOI":"10.3390\/onco5020026","volume":"5","author":"G Fiorentini","year":"2025","unstructured":"Fiorentini G, Sarti D, Mambrini A, Mattioli G, Bonucci M, Ginocchi L, et al. Locoregional hyperthermia in cancer treatment: a narrative review with updates and perspectives. Onco. 2025;5(2):26. https:\/\/doi.org\/10.3390\/onco5020026.","journal-title":"Onco"},{"key":"1633_CR4","doi-asserted-by":"publisher","first-page":"1571","DOI":"10.1134\/S0031918X25601908","volume":"126","author":"AM Tishin","year":"2025","unstructured":"Tishin AM. Modern applications of magnetic materials: trends and challenges. Magnet Magn Mater Spintr. 2025;126:1571\u201389. https:\/\/doi.org\/10.1134\/S0031918X25601908.","journal-title":"Magnet Magn Mater Spintr"},{"key":"1633_CR5","doi-asserted-by":"publisher","first-page":"245","DOI":"10.1038\/s44222-024-00257-3","volume":"3","author":"A Shakeri-Zadeh","year":"2025","unstructured":"Shakeri-Zadeh A, Bulte JWM. Imaging-guided precision hyperthermia with magnetic nanoparticles. Nat Rev Bioeng. 2025;3:245\u201360. https:\/\/doi.org\/10.1038\/s44222-024-00257-3.","journal-title":"Nat Rev Bioeng"},{"issue":"1","key":"1633_CR6","doi-asserted-by":"publisher","DOI":"10.1016\/j.jics.2021.100269","volume":"99","author":"M Peiravi","year":"2022","unstructured":"Peiravi M, Eslami H, Ansari M, Zare-Zardini H. Magnetic hyperthermia: potentials and limitations. J Indian Chem Soc. 2022;99(1):100269. https:\/\/doi.org\/10.1016\/j.jics.2021.100269.","journal-title":"J Indian Chem Soc"},{"issue":"5","key":"1633_CR7","doi-asserted-by":"publisher","first-page":"1394","DOI":"10.3390\/cancers15051394","volume":"15","author":"P Vaupel","year":"2023","unstructured":"Vaupel P, Piazena H, Notter M, Thomsen AR, Grosu AL, Scholkmann F, et al. From localized mild hyperthermia to improved tumor oxygenation: physiological mechanisms critically involved in oncologic thermo-radio-immunotherapy. Cancers. 2023;15(5):1394. https:\/\/doi.org\/10.3390\/cancers15051394.","journal-title":"Cancers"},{"issue":"1","key":"1633_CR8","doi-asserted-by":"publisher","first-page":"13","DOI":"10.4103\/0973-0168.184606","volume":"7","author":"NG Shetake","year":"2016","unstructured":"Shetake NG, Balla MMS, Kumar A, Pandey BN. Magnetic hyperthermia therapy an emerging modality of cancer treatment in combination with radiotherapy. J Radiat Cancer Res. 2016;7(1):13\u20137. https:\/\/doi.org\/10.4103\/0973-0168.184606.","journal-title":"J Radiat Cancer Res"},{"issue":"1","key":"1633_CR9","doi-asserted-by":"publisher","first-page":"2391008","DOI":"10.1080\/02656736.2024.2391008","volume":"41","author":"RV Stigliano","year":"2024","unstructured":"Stigliano RV, Danelyan I, Gabriadze G, Shoshiashvili L, Baker I, Hoopes PJ, et al. Alternating magnetic field guiding system for MNP hyperthermia treatment of deep-seated cancers. Int J Hyperth. 2024;41(1):2391008. https:\/\/doi.org\/10.1080\/02656736.2024.2391008.","journal-title":"Int J Hyperth"},{"key":"1633_CR10","doi-asserted-by":"publisher","DOI":"10.1016\/j.biomaterials.2020.120299","volume":"259","author":"KY Qian","year":"2020","unstructured":"Qian KY, Song Y, Yan X, Dong L, Xue J, Xu Y, et al. Injectable ferrimagnetic silk fibroin hydrogel for magnetic hyperthermia ablation of deep tumor. Biomaterials. 2020;259:120299. https:\/\/doi.org\/10.1016\/j.biomaterials.2020.120299.","journal-title":"Biomaterials"},{"key":"1633_CR11","doi-asserted-by":"publisher","DOI":"10.1007\/s44174-025-00593-x","author":"S Naik","year":"2025","unstructured":"Naik S, Munjal S. Nanotechnology-driven advances in magnetic hyperthermia: a comprehensive review. Biomed Mater Dev. 2025. https:\/\/doi.org\/10.1007\/s44174-025-00593-x.","journal-title":"Biomed Mater Dev"},{"key":"1633_CR12","doi-asserted-by":"publisher","DOI":"10.1007\/s11051-020-04986-5","author":"LH Nguyen","year":"2020","unstructured":"Nguyen LH, Oanh VTK, Nam PH, Doan DH, Truong NX, Ca NX, et al. Increase of magnetic hyperthermia efficiency due to optimal size of particles: theoretical and experimental results. J Nanopart Res. 2020. https:\/\/doi.org\/10.1007\/s11051-020-04986-5.","journal-title":"J Nanopart Res"},{"key":"1633_CR13","doi-asserted-by":"publisher","first-page":"11614","DOI":"10.1039\/D1CS00427A","volume":"50","author":"H Gavilan","year":"2021","unstructured":"Gavilan H, Avugadda SK, Fernandez-Cabada T, Soni N, Cassani M, Mai BT, et al. Magnetic nanoparticles and clusters for magnetic hyperthermia: optimizing their heat performance and developing combinatorial therapies to tackle cancer. Chem Soc Rev. 2021;50:11614\u201367. https:\/\/doi.org\/10.1039\/D1CS00427A.","journal-title":"Chem Soc Rev"},{"key":"1633_CR14","doi-asserted-by":"publisher","DOI":"10.1109\/JERM.2026.3664393","author":"J Choi","year":"2026","unstructured":"Choi J, Song M, Kim H, Lee H, Kim H, Park S. Design and experimental validation of series-resonated helmholtz coil system for magnetic nanoparticle hyperthermia. IEEE J Electromagn RF Microwav Med Biol. 2026. https:\/\/doi.org\/10.1109\/JERM.2026.3664393.","journal-title":"IEEE J Electromagn RF Microwav Med Biol"},{"key":"1633_CR15","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1080\/15368378.2025.2524547","volume":"44","author":"M Chatterjee","year":"2025","unstructured":"Chatterjee M, Pal S. Design and performance evaluation of magnetic hyperthermia instrument with embedded pi control. Electromagn Biol Med. 2025;44:1\u201315. https:\/\/doi.org\/10.1080\/15368378.2025.2524547.","journal-title":"Electromagn Biol Med"},{"key":"1633_CR16","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1109\/TIM.2025.3542151","volume":"74","author":"EEM Valadez","year":"2025","unstructured":"Valadez EEM, Uliana JH, Vicente TT, Carneiro AAO, Pavan TZ. Fully-automated theranostic system integrating magnetomotive ultrasound and magnetic hyperthermia. IEEE Trans Instrum Meas. 2025;74:1\u201311. https:\/\/doi.org\/10.1109\/TIM.2025.3542151.","journal-title":"IEEE Trans Instrum Meas"},{"key":"1633_CR17","doi-asserted-by":"publisher","first-page":"105805","DOI":"10.1109\/ACCESS.2021.3099428","volume":"9","author":"M Zeinoun","year":"2021","unstructured":"Zeinoun M, Serrano D, Medina PT, Garcia O, Vasic M, Serrani-Olmedo JJ. Configurable high-frequency alternating magnetic field generator for nanomedical magnetic hyperthermia applications. IEEE Access. 2021;9:105805\u201316. https:\/\/doi.org\/10.1109\/ACCESS.2021.3099428.","journal-title":"IEEE Access"},{"issue":"1","key":"1633_CR18","doi-asserted-by":"publisher","first-page":"243","DOI":"10.1109\/JESTPE.2015.2479092","volume":"4","author":"O Garcia","year":"2016","unstructured":"Garcia O, Moreno-Arrones N, Cuesta AB, Gutierres A, Alou P, Oliver JA, et al. Development and testing of a new instrument for researching on cancer treatment technologies based on magnetic hyperthermia. IEEE J Emerg Select Top Power Electr. 2016;4(1):243\u201351. https:\/\/doi.org\/10.1109\/JESTPE.2015.2479092.","journal-title":"IEEE J Emerg Select Top Power Electr"},{"issue":"1","key":"1633_CR19","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1080\/02656736.2019.1704448","volume":"37","author":"A Attaluri","year":"2020","unstructured":"Attaluri A, Jackowski J, Sharma A, Kandala SK, Nemkov V, Yakey C, et al. Design and construction of a maxwell-type induction coil for magnetic nanoparticle hyperthermia. Int J Hyperth. 2020;37(1):1\u201314. https:\/\/doi.org\/10.1080\/02656736.2019.1704448.","journal-title":"Int J Hyperth"},{"key":"1633_CR20","doi-asserted-by":"publisher","DOI":"10.2139\/ssrn.6735899","author":"SI Y\u00f6ner","year":"2026","unstructured":"Y\u00f6ner SI, Ozcan A, Akin O. Characterizing magnetic hyperthermia RF generator spectral purity at 150 kHz: The harmonic residual index as a standardized metric for inductive safety. SSRN Electr J. 2026. https:\/\/doi.org\/10.2139\/ssrn.6735899.","journal-title":"SSRN Electr J"},{"key":"1633_CR21","volume-title":"Design and optimization of a nanoparticle based magnetic hyperthermia device","author":"SI Yoner","year":"2025","unstructured":"Yoner SI. Design and optimization of a nanoparticle based magnetic hyperthermia device. Istanbul: Bogazici University; 2025."},{"key":"1633_CR22","unstructured":"MagForce Nanotechnologies AG: NanoActivator F100: Clinical Induction Heating System for Magnetic Hyperthermia. MagForce Nanotechnologies AG, Berlin, Germany. 2026. MagForce Nanotechnologies AG. https:\/\/www.magforce.de\/. Accessed on 17 Aug 2026."},{"key":"1633_CR23","unstructured":"nanoTherics Ltd: magneTherm: High-Frequency Magnetic Field Generator for Nanoparticle Research. nanoTherics Ltd, Warrington, United Kingdom. nanoTherics Ltd. 2026. https:\/\/www.nanotherics.com\/. Accessed 17 Aug 2026."},{"issue":"6","key":"1633_CR24","doi-asserted-by":"publisher","first-page":"1444","DOI":"10.1118\/1.1748629","volume":"31","author":"U Gneveckow","year":"2004","unstructured":"Gneveckow U, Jordan A, Scholz R, Br\u00fcss V, Wald\u00f6fner N, Ricke J, et al. Description and characterization of the novel hyperthermia- and thermoablation-system MFH 300f for clinical magnetic fluid hyperthermia. Med Phys. 2004;31(6):1444\u201351. https:\/\/doi.org\/10.1118\/1.1748629.","journal-title":"Med Phys"},{"issue":"2","key":"1633_CR25","doi-asserted-by":"publisher","first-page":"235","DOI":"10.1109\/TBME.1984.325772","volume":"31","author":"PR Stauffer","year":"1984","unstructured":"Stauffer PR, Cetas TC, Jones RC. Magnetic induction heating of ferromagnetic implants for inducing localized hyperthermia in deep-seated tumors. IEEE Trans Biomed Eng. 1984;31(2):235\u201351. https:\/\/doi.org\/10.1109\/TBME.1984.325772.","journal-title":"IEEE Trans Biomed Eng"},{"issue":"3","key":"1633_CR26","doi-asserted-by":"publisher","first-page":"621","DOI":"10.3390\/cancers16030621","volume":"16","author":"N Levi-Polyachenko","year":"2024","unstructured":"Levi-Polyachenko N, et al. A validated methodological approach to prove the safety of clinical electromagnetic induction systems in magnetic hyperthermia. Cancers. 2024;16(3):621. https:\/\/doi.org\/10.3390\/cancers16030621.","journal-title":"Cancers"},{"issue":"1","key":"1633_CR27","doi-asserted-by":"publisher","first-page":"81","DOI":"10.1080\/02656736.2021.2011434","volume":"39","author":"V Sadaphal","year":"2022","unstructured":"Sadaphal V, Prasad B, Kay W, Nehring L, Nyugen T, Tepper J, et al. Feasibility of heating metal implants with alternating magnetic fields (AMF) in scaled up models. Int J Hyperth. 2022;39(1):81\u201396. https:\/\/doi.org\/10.1080\/02656736.2021.2011434.","journal-title":"Int J Hyperth"},{"issue":"8","key":"1633_CR28","doi-asserted-by":"publisher","first-page":"715","DOI":"10.3109\/02656736.2013.836758","volume":"29","author":"CL Dennis","year":"2013","unstructured":"Dennis CL, Ivkov R. Physics of heat generation using magnetic nanoparticles for hyperthermia. Int J Hyperth. 2013;29(8):715\u201329. https:\/\/doi.org\/10.3109\/02656736.2013.836758.","journal-title":"Int J Hyperth"},{"key":"1633_CR29","doi-asserted-by":"publisher","DOI":"10.1063\/1.4729271","volume":"111","author":"EL Verde","year":"2012","unstructured":"Verde EL, Landi GT, Gomes JA, Sousa MH, Bakuzis AF. Magnetic hyperthermia investigation of cobalt ferrite nanoparticles: comparison between experiment, linear response theory, and dynamic hysteresis simulations. J Appl Phys. 2012;111:123902. https:\/\/doi.org\/10.1063\/1.4729271.","journal-title":"J Appl Phys"},{"issue":"8","key":"1633_CR30","doi-asserted-by":"publisher","DOI":"10.1063\/1.3551582","volume":"109","author":"J Carrey","year":"2011","unstructured":"Carrey J, Mehdaoui B, Respaud M. Simple models for dynamic hysteresis loop calculations of magnetic single-domain nanoparticles: application to magnetic hyperthermia optimization. J Appl Phys. 2011;109(8):083921. https:\/\/doi.org\/10.1063\/1.3551582.","journal-title":"J Appl Phys"},{"issue":"1","key":"1633_CR31","doi-asserted-by":"publisher","first-page":"70","DOI":"10.1109\/TBME.1984.325372","volume":"31","author":"WJ Atkinson","year":"1984","unstructured":"Atkinson WJ, Brezovich IA, Chakraborty DP. Usable frequencies in hyperthermia with thermal seeds. IEEE Transact Biomed Eng BME. 1984;31(1):70\u20135. https:\/\/doi.org\/10.1109\/TBME.1984.325372.","journal-title":"IEEE Transact Biomed Eng BME"},{"issue":"10 Supplement","key":"1633_CR32","first-page":"4752","volume":"44","author":"IA Brezovich","year":"1984","unstructured":"Brezovich IA, Atkinson WJ, Lilly MB. Local hyperthermia with interstitial techniques. Can Res. 1984;44(10 Supplement):4752\u20136.","journal-title":"Can Res"},{"issue":"1","key":"1633_CR33","doi-asserted-by":"publisher","first-page":"187","DOI":"10.1016\/j.jmmm.2006.10.1156","volume":"311","author":"R Hergt","year":"2007","unstructured":"Hergt R, Dutz S. Magnetic particle hyperthermia biophysical limitations of a visionary tumour therapy. J Magn Magn Mater. 2007;311(1):187\u201392. https:\/\/doi.org\/10.1016\/j.jmmm.2006.10.1156.","journal-title":"J Magn Magn Mater"},{"key":"1633_CR34","volume-title":"Audio Power Amplifier Design Handbook","author":"D Self","year":"2006","unstructured":"Self D. Audio Power Amplifier Design Handbook. 4th ed. Burlington: Newnes; 2006.","edition":"4"},{"key":"1633_CR35","doi-asserted-by":"publisher","DOI":"10.1002\/9781118717806","volume-title":"High-frequency magnetic components","author":"MK Kazimierczuk","year":"2013","unstructured":"Kazimierczuk MK. High-frequency magnetic components. 2nd ed. Chichester: Wiley; 2013.","edition":"2"},{"issue":"1","key":"1633_CR36","doi-asserted-by":"publisher","first-page":"392","DOI":"10.1109\/TAES.2017.2760560","volume":"54","author":"DD Batista","year":"2018","unstructured":"Batista DD, Granziera F, Tosin MC, Melo LF. Three-axial helmholtz coil design and validation for aerospace applications. IEEE Trans Aerosp Electron Syst. 2018;54(1):392\u2013403. https:\/\/doi.org\/10.1109\/TAES.2017.2760560.","journal-title":"IEEE Trans Aerosp Electron Syst"},{"issue":"12","key":"1633_CR37","doi-asserted-by":"publisher","first-page":"802","DOI":"10.5185\/amp.2017\/918","volume":"2","author":"SK Ghosh","year":"2017","unstructured":"Ghosh SK, Thakur V, Chowdhury SR. Design and simulation of helmholtz coil and maxwell coil for low cost and low magnetic field MRI machine. Adv Mater Proc. 2017;2(12):802\u20136. https:\/\/doi.org\/10.5185\/amp.2017\/918.","journal-title":"Adv Mater Proc"},{"key":"1633_CR38","doi-asserted-by":"publisher","DOI":"10.1007\/978-3-030-43881-4","volume-title":"Fundamentals of Power Electronics","author":"RW Erickson","year":"2020","unstructured":"Erickson RW, Maksimovic D. Fundamentals of Power Electronics. 3rd ed. Cham: Springer; 2020.","edition":"3"},{"key":"1633_CR39","volume-title":"Microwave Engineering","author":"DM Pozar","year":"2012","unstructured":"Pozar DM. Microwave Engineering. 4th ed. Hoboken: Wiley; 2012.","edition":"4"},{"key":"1633_CR40","doi-asserted-by":"publisher","DOI":"10.1007\/978-94-011-6950-9","volume-title":"High-frequency circuit design and measurements","author":"PCL Yip","year":"1990","unstructured":"Yip PCL. High-frequency circuit design and measurements. 1st ed. Boston, MA: Springer; 1990.","edition":"1"},{"key":"1633_CR41","unstructured":"Scientific India. https:\/\/www.scientificindia.com\/. Accessed on 06 May 2026."},{"key":"1633_CR42","unstructured":"Intertechnology V. 2008. IRF540 power MOSFET datasheet. https:\/\/www.vishay.com\/docs\/91021\/irf540.pdf. Accessed on 06 May 2026."},{"key":"1633_CR43","unstructured":"Instruments T. 2015. UCC3895DW phase-shift PWM controller datasheet. https:\/\/www.ti.com\/lit\/ds\/symlink\/ucc3895.pdf. Accessed on 06 May 2026."},{"key":"1633_CR44","unstructured":"AG, I.T.: FF150R12RT4 IGBT module datasheet. 2013. https:\/\/www.infineon.com\/dgdl\/ff150r12rt4.pdf. Accessed on 06 May 2026."},{"key":"1633_CR45","unstructured":"AMF Life. https:\/\/amflife.com\/. Accessed on 6 May 2026."},{"key":"1633_CR46","unstructured":"STMicroelectronics: STM32F446MC microcontroller datasheet. 2015. https:\/\/www.st.com\/resource\/en\/datasheet\/stm32f446mc.pdf. Accessed on 6 May 2026."},{"key":"1633_CR47","unstructured":"Mean Well. https:\/\/www.meanwell.com\/. Accessed on 6 May 2026."},{"key":"1633_CR48","unstructured":"Zhang N, Li D, Zhang V, Chen A. Reduce conducted emi in automotive buck converter applications. Technical Report SNVA886, Texas Instruments. 2019. https:\/\/www.ti.com\/lit\/an\/snva886\/snva886.pdf."},{"key":"1633_CR49","volume-title":"Switching power supply design","author":"AI Pressman","year":"2009","unstructured":"Pressman AI, Billings K, Morey T. Switching power supply design. 3rd ed. New York: McGraw-Hill; 2009.","edition":"3"},{"key":"1633_CR50","doi-asserted-by":"publisher","unstructured":"Lucia O, Burd JM, Millan I, Acero J, Barragan LA. Efficiency-oriented design of zvs half-bridge series resonant inverter with variable frequency duty cycle control. IEEE Transact Power Electr. 2010;25(7):1671\u20134. https:\/\/doi.org\/10.1109\/TPEL.2010.2042461.","DOI":"10.1109\/TPEL.2010.2042461"},{"key":"1633_CR51","volume-title":"Embedded systems architecture: a comprehensive guide for engineers and programmers","author":"T Noergaard","year":"2012","unstructured":"Noergaard T. Embedded systems architecture: a comprehensive guide for engineers and programmers. 2nd ed. Burlington, MA: Newnes; 2012.","edition":"2"},{"key":"1633_CR52","doi-asserted-by":"publisher","DOI":"10.1007\/978-981-99-7755-0","volume-title":"FPGA EDA","author":"K Tu","year":"2024","unstructured":"Tu K, Tang X, Yu C, Josipovic L, Chu Z. FPGA EDA. 1st ed. Singapore: Springer; 2024.","edition":"1"},{"key":"1633_CR53","doi-asserted-by":"publisher","DOI":"10.1088\/978-0-7503-5512-4","volume-title":"Essential microelectronic circuits","author":"Y Zhang","year":"2025","unstructured":"Zhang Y. Essential microelectronic circuits. 2nd ed. Bristol: IOP Publishing; 2025.","edition":"2"},{"key":"1633_CR54","unstructured":"Andreycak B. Zero voltage switching resonant power conversion. Technical report, Texas Instruments. 2001. https:\/\/www.ti.com\/lit\/ml\/slup089\/slup089.pdf."},{"key":"1633_CR55","doi-asserted-by":"publisher","DOI":"10.1201\/9781315117485","volume-title":"Handbook of induction heating","author":"V Rudnev","year":"2017","unstructured":"Rudnev V, Loveless D, Cook RL. Handbook of induction heating. 2nd ed. Boca Raton, FL: CRC Press; 2017.","edition":"2"},{"issue":"6","key":"1633_CR56","doi-asserted-by":"publisher","first-page":"1250","DOI":"10.1109\/63.892840","volume":"15","author":"K Sheng","year":"2000","unstructured":"Sheng K, Williams BW, Finney SJ. A review of IGBT models. IEEE Trans Power Electron. 2000;15(6):1250\u201366. https:\/\/doi.org\/10.1109\/63.892840.","journal-title":"IEEE Trans Power Electron"},{"issue":"6","key":"1633_CR57","doi-asserted-by":"publisher","first-page":"6069","DOI":"10.1109\/TIA.2021.3111540","volume":"57","author":"SS Ahmad","year":"2021","unstructured":"Ahmad SS, Urabinahatti C, Prasad KNV, Narayanan G. High-switching-frequency sic power converter for high-speed switched reluctance machine. IEEE Trans Ind Appl. 2021;57(6):6069\u201382. https:\/\/doi.org\/10.1109\/TIA.2021.3111540.","journal-title":"IEEE Trans Ind Appl"},{"key":"1633_CR58","doi-asserted-by":"publisher","DOI":"10.1017\/CBO9781139015349","volume-title":"Handbook of RF and microwave power amplifiers","author":"JLB Walker","year":"2011","unstructured":"Walker JLB. Handbook of RF and microwave power amplifiers. 1st ed. Cambridge: Cambridge University Press; 2011.","edition":"1"},{"key":"1633_CR59","doi-asserted-by":"publisher","DOI":"10.1103\/PhysRevApplied.21.064037","volume":"21","author":"G Barrera","year":"2024","unstructured":"Barrera G, Allia P, Tiberto P. Magnetic nanoparticle hyperthermia enhanced by a rotating field. Phys Rev Appl. 2024;21:064037. https:\/\/doi.org\/10.1103\/PhysRevApplied.21.064037.","journal-title":"Phys Rev Appl"},{"key":"1633_CR60","doi-asserted-by":"publisher","first-page":"73","DOI":"10.1002\/cmr.1820010205","volume":"1","author":"DD Traficante","year":"1989","unstructured":"Traficante DD. Impedance: what it is, and why it must be matched. Concepts Magn Resonance. 1989;1:73\u201392. https:\/\/doi.org\/10.1002\/cmr.1820010205.","journal-title":"Concepts Magn Resonance"},{"key":"1633_CR61","doi-asserted-by":"publisher","DOI":"10.1088\/978-0-7503-5296-3","volume-title":"Resonant network antennas for radio-frequency plasma sources","author":"P Guittienne","year":"2024","unstructured":"Guittienne P, Howling A, Furno I. Resonant network antennas for radio-frequency plasma sources. 1st ed. Bristol: IOP Publishing; 2024.","edition":"1"},{"issue":"5","key":"1633_CR62","doi-asserted-by":"publisher","first-page":"313","DOI":"10.1109\/LMWC.2016.2548997","volume":"26","author":"R Darraji","year":"2016","unstructured":"Darraji R, Honari MM, Mirzavand R, Ghannouchi FM, Mousavi P. Wideband two-section impedance transformer with flat real-to-real impedance matching. IEEE Microwave Wirel Compon Lett. 2016;26(5):313\u20135. https:\/\/doi.org\/10.1109\/LMWC.2016.2548997.","journal-title":"IEEE Microwave Wirel Compon Lett"},{"issue":"7","key":"1633_CR63","doi-asserted-by":"publisher","first-page":"6894","DOI":"10.1109\/TIE.2023.3314863","volume":"71","author":"H Pang","year":"2024","unstructured":"Pang H, Xu F, Liu W, Tse CK, Chau KT. Impedance buffer-based reactance cancellation method for clc-s compensated wireless power transfer. IEEE Trans Industr Electron. 2024;71(7):6894\u2013906. https:\/\/doi.org\/10.1109\/TIE.2023.3314863.","journal-title":"IEEE Trans Industr Electron"},{"key":"1633_CR64","doi-asserted-by":"publisher","first-page":"95","DOI":"10.1002\/cmr.1820070202","volume":"7","author":"ZH Cho","year":"1995","unstructured":"Cho ZH, Yi JH. Planar surface gradient coil. Concepts Magnet Resonance. 1995;7:95\u2013114. https:\/\/doi.org\/10.1002\/cmr.1820070202.","journal-title":"Concepts Magnet Resonance"},{"key":"1633_CR65","doi-asserted-by":"publisher","first-page":"21361","DOI":"10.1002\/cmr.b.21361","volume":"47B","author":"G Giovannetti","year":"2017","unstructured":"Giovannetti G, Flori A, De Marchi D, Matarazzo G, Frijia F, Burchielli S, et al. Simulation, design, and test of an elliptical surface coil for magnetic resonance imaging and spectroscopy. Conc Magn Resonance Part B. 2017;47B:21361. https:\/\/doi.org\/10.1002\/cmr.b.21361.","journal-title":"Conc Magn Resonance Part B"},{"issue":"3","key":"1633_CR66","doi-asserted-by":"publisher","DOI":"10.1088\/1674-1137\/38\/3\/037001","volume":"38","author":"Y Xiao-Liang","year":"2014","unstructured":"Xiao-Liang Y, Zhong L, Min L, Guang-Yao L, Qiang K, Jie T, et al. Design of sc solenoid with high homogeneity. Chin Phys C. 2014;38(3):037001. https:\/\/doi.org\/10.1088\/1674-1137\/38\/3\/037001.","journal-title":"Chin Phys C"},{"key":"1633_CR67","doi-asserted-by":"publisher","first-page":"4187","DOI":"10.1038\/s41598-023-31389-y","volume":"13","author":"CM Awuah","year":"2023","unstructured":"Awuah CM, Danuor P, Moon JI, Jung YB. Novel coil design and analysis for high-power wireless power transfer with enhanced q-factor. Sci Rep. 2023;13:4187. https:\/\/doi.org\/10.1038\/s41598-023-31389-y.","journal-title":"Sci Rep"},{"key":"1633_CR68","doi-asserted-by":"publisher","first-page":"129754","DOI":"10.1109\/ACCESS.2020.3009367","volume":"8","author":"MSM Mollaei","year":"2020","unstructured":"Mollaei MSM, Van Leeuwen CC, Raaijmakers AJE, Simovski CR. Analysis of high impedance coils both in transmission and reception regimes. IEEE Access. 2020;8:129754\u201362. https:\/\/doi.org\/10.1109\/ACCESS.2020.3009367.","journal-title":"IEEE Access"},{"key":"1633_CR69","doi-asserted-by":"publisher","DOI":"10.31399\/asm.tb.eihdca.9781627083416","volume-title":"Elements of induction heating: design, control, and applications","author":"S Zinn","year":"1988","unstructured":"Zinn S, Semiatin SL. Elements of induction heating: design, control, and applications. 1st ed. Materials Park: ASM International; 1988.","edition":"1"},{"key":"1633_CR70","doi-asserted-by":"publisher","first-page":"10","DOI":"10.1016\/j.renene.2016.06.025","volume":"99","author":"Y Cui","year":"2016","unstructured":"Cui Y, Wang Y, Huang Q, Wei S. Effect of radiation and convection heat transfer on cooling performance of radiative panel. Renewable Energy. 2016;99:10\u20137. https:\/\/doi.org\/10.1016\/j.renene.2016.06.025.","journal-title":"Renewable Energy"},{"key":"1633_CR71","doi-asserted-by":"publisher","DOI":"10.1007\/978-3-319-03479-9","volume-title":"Induction and direct resistance heating: theory and numerical modeling","author":"S Lupi","year":"2015","unstructured":"Lupi S, Forzan M, Aliferov A. Induction and direct resistance heating: theory and numerical modeling. 1st ed. Cham: Springer; 2015.","edition":"1"},{"key":"1633_CR72","unstructured":"Optris. https:\/\/optris.com\/. Accessed on 09 May 2026."},{"issue":"1","key":"1633_CR73","doi-asserted-by":"publisher","first-page":"17","DOI":"10.1080\/16070658.1982.11689261","volume":"17","author":"D Chakraborty","year":"1982","unstructured":"Chakraborty D, Brezovich I. Error sources affecting thermocouple thermometry in rf electromagnetic fields. J Microwave Power. 1982;17(1):17\u201328. https:\/\/doi.org\/10.1080\/16070658.1982.11689261.","journal-title":"J Microwave Power"},{"issue":"1","key":"1633_CR74","doi-asserted-by":"publisher","first-page":"303","DOI":"10.1007\/s13244-018-0601-x","volume":"9","author":"GT Yusuf","year":"2018","unstructured":"Yusuf GT, Fang C, Huang DY, Sellars ME, Deganello A, Sidhu PS. Endocavitary contrast enhanced ultrasound (ceus): a novel problem solving technique. Insights Imag. 2018;9(1):303\u201311. https:\/\/doi.org\/10.1007\/s13244-018-0601-x.","journal-title":"Insights Imag"},{"key":"1633_CR75","unstructured":"Verasonics. https:\/\/verasonics.com\/. Accessed on 09 May 2026."},{"key":"1633_CR76","doi-asserted-by":"publisher","first-page":"177","DOI":"10.1016\/j.jmmm.2016.07.018","volume":"420","author":"A Skumiel","year":"2016","unstructured":"Skumiel A, Leszczynski B, Molcan M, Timko M. The comparison of magnetic circuits used in magnetic hyperthermia. J Magn Magn Mater. 2016;420:177\u201384. https:\/\/doi.org\/10.1016\/j.jmmm.2016.07.018.","journal-title":"J Magn Magn Mater"},{"key":"1633_CR77","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijthermalsci.2024.109151","volume":"203","author":"M Vicentini","year":"2024","unstructured":"Vicentini M, Ferrero R, Manzin A. Influence of coil geometry, supply conditions and nanoparticle heating properties on magnetic hyperthermia in mouse models. Int J Therm Sci. 2024;203:109151. https:\/\/doi.org\/10.1016\/j.ijthermalsci.2024.109151.","journal-title":"Int J Therm Sci"},{"issue":"4","key":"1633_CR78","doi-asserted-by":"publisher","DOI":"10.1115\/1.4071394","volume":"9","author":"A Gupta","year":"2026","unstructured":"Gupta A, Yadav AK. Numerical analysis of solenoidal and helmholtz coils for magnetic hyperthermia with intratumoral nanofluid injection. ASME J Med Diagn. 2026;9(4):041201. https:\/\/doi.org\/10.1115\/1.4071394.","journal-title":"ASME J Med Diagn"},{"issue":"2","key":"1633_CR79","doi-asserted-by":"publisher","first-page":"109","DOI":"10.1109\/JERM.2019.2945833","volume":"4","author":"D Brizi","year":"2020","unstructured":"Brizi D, Fontana N, Giovannetti G, Menichetti L, Cappiello L, Doumett S. A radiating system for low-frequency highly focused hyperthermia with magnetic nanoparticles. IEEE J Electromagn RF Microwav Med Biol. 2020;4(2):109\u201316. https:\/\/doi.org\/10.1109\/JERM.2019.2945833.","journal-title":"IEEE J Electromagn RF Microwav Med Biol"},{"issue":"22","key":"1633_CR80","doi-asserted-by":"publisher","first-page":"8326","DOI":"10.3390\/en15228326","volume":"15","author":"A Skumiel","year":"2022","unstructured":"Skumiel A, Wojciechowski RM. Two-phase system for generating a higher-frequency rotating magnetic field excited causing hyperthermic effect in magnetic fluids. Energies. 2022;15(22):8326. https:\/\/doi.org\/10.3390\/en15228326.","journal-title":"Energies"},{"issue":"22","key":"1633_CR81","doi-asserted-by":"publisher","DOI":"10.1016\/j.measurement.2022.111020","volume":"194","author":"RM Wojciechowski","year":"2022","unstructured":"Wojciechowski RM, Skumiel A, Kurzawa M, Demenko A. Design, application and investigation of the system for generation of fast changing, rotating magnetic field causing hyperthermic effect in magnetic liquids. Measurement. 2022;194(22):111020. https:\/\/doi.org\/10.1016\/j.measurement.2022.111020.","journal-title":"Measurement"},{"issue":"3","key":"1633_CR82","doi-asserted-by":"publisher","first-page":"21","DOI":"10.3390\/magnetism5030021","volume":"5","author":"A Skumiel","year":"2025","unstructured":"Skumiel A. Comparison of two- and three-phase devices generating a rotating magnetic field for magnetic hyperthermia applications. Magnetism. 2025;5(3):21. https:\/\/doi.org\/10.3390\/magnetism5030021.","journal-title":"Magnetism"},{"key":"1633_CR83","doi-asserted-by":"publisher","DOI":"10.1016\/j.jmmm.2021.168528","volume":"541","author":"Z Isz\u00e1ly","year":"2022","unstructured":"Isz\u00e1ly Z, M\u00e1ri\u00e1n IG, Szab\u00f3 IA, Trombettoni A, N\u00e1ndori I. Theory of superlocalized magnetic nanoparticle hyperthermia: rotating versus oscillating fields. J Magn Magn Mater. 2022;541:168528. https:\/\/doi.org\/10.1016\/j.jmmm.2021.168528.","journal-title":"J Magn Magn Mater"},{"issue":"01n02","key":"1633_CR84","doi-asserted-by":"publisher","first-page":"17","DOI":"10.1142\/S1793984410000067","volume":"1","author":"AJ Giustini","year":"2010","unstructured":"Giustini AJ, Petryk AA, Cassim SM, Tate JA, Baker I, Hoopes PJ. Magnetic nanoparticle hyperthermia in cancer treatment. Nano LIFE. 2010;1(01n02):17\u201332. https:\/\/doi.org\/10.1142\/S1793984410000067.","journal-title":"Nano LIFE"},{"key":"1633_CR85","doi-asserted-by":"publisher","first-page":"831","DOI":"10.3389\/fphar.2018.00831","volume":"9","author":"D Chang","year":"2018","unstructured":"Chang D, Lim M, Goos JACM, Qiao R, Ng YY, Mansfeld FM, et al. Biologically targeted magnetic hyperthermia: potential and limitations. Front Pharmacol. 2018;9:831. https:\/\/doi.org\/10.3389\/fphar.2018.00831.","journal-title":"Front Pharmacol"},{"key":"1633_CR86","doi-asserted-by":"publisher","DOI":"10.1007\/978-1-4613-2213-9_61","volume-title":"Adv Cryog Eng","author":"K Pieterman","year":"1986","unstructured":"Pieterman K, Dam JAM, Postma H. Low temperature closed cooling system for MRI magnets. In: Fast RW, editor. Adv Cryog Eng, vol. 31. Boston, MA: Springer; 1986. https:\/\/doi.org\/10.1007\/978-1-4613-2213-9_61."},{"key":"1633_CR87","doi-asserted-by":"publisher","first-page":"2144","DOI":"10.1007\/s43236-025-01177-0","volume":"25","author":"ES Kim","year":"2025","unstructured":"Kim ES, Park SM. Enhanced modeling of load behavior in high-efficiency dual-coil induction heating systems. J Power Electr. 2025;25:2144\u201352. https:\/\/doi.org\/10.1007\/s43236-025-01177-0.","journal-title":"J Power Electr"},{"key":"1633_CR88","doi-asserted-by":"publisher","DOI":"10.1007\/s42452-021-04447-1","author":"AK Alamouti","year":"2021","unstructured":"Alamouti AK, Habibi MR, Sharfabadi MM, Lalimi HA. Numerical study on the effects of blood perfusion and tumor metabolism on tumor temperature for targeted hyperthermia considering a realistic geometrical model of head layers using the finite element method. SN Appl Sci. 2021. https:\/\/doi.org\/10.1007\/s42452-021-04447-1.","journal-title":"SN Appl Sci"},{"key":"1633_CR89","doi-asserted-by":"publisher","DOI":"10.1016\/j.phymed.2020.153402","author":"F Sadeghi","year":"2025","unstructured":"Sadeghi F, Zarandi HRM, Ahangar HA, Mollaei MH, Torabi M, Ghasemi M, et al. A comprehensive modeling on thermal damage in tumor hyperthermia therapies using magneto-plasmonic nanocomposite. Sci Rep. 2025. https:\/\/doi.org\/10.1016\/j.phymed.2020.153402.","journal-title":"Sci Rep"},{"issue":"1","key":"1633_CR90","doi-asserted-by":"publisher","DOI":"10.1098\/rsos.201234","volume":"8","author":"JJ Bosque","year":"2021","unstructured":"Bosque JJ, Calvo GF, Perez-Garcia VM, Navarro MC. The interplay of blood flow and temperature in regional hyperthermia: a mathematical approach. Roy Soc Open Sci. 2021;8(1):201234. https:\/\/doi.org\/10.1098\/rsos.201234.","journal-title":"Roy Soc Open Sci"},{"issue":"7","key":"1633_CR91","doi-asserted-by":"publisher","first-page":"735","DOI":"10.1080\/02656736.2016.1195018","volume":"32","author":"RV Stigliano","year":"2016","unstructured":"Stigliano RV, Shubitidze F, Petryk JD, Shoshiashvili L, Petryk AA, Hoopes PJ. Mitigation of eddy current heating during magnetic nanoparticle hyperthermia therapy. Int J Hyperth. 2016;32(7):735\u201348. https:\/\/doi.org\/10.1080\/02656736.2016.1195018.","journal-title":"Int J Hyperth"},{"issue":"24","key":"1633_CR92","doi-asserted-by":"publisher","DOI":"10.1063\/5.0153336","volume":"122","author":"MKY Kwok","year":"2023","unstructured":"Kwok MKY, Maley CCJ, Dworkin A, Hattersley S, Southern P, Pankhurst QA. Nonspecific eddy current heating in magnetic field hyperthermia. Appl Phys Lett. 2023;122(24):240502. https:\/\/doi.org\/10.1063\/5.0153336.","journal-title":"Appl Phys Lett"},{"key":"1633_CR93","doi-asserted-by":"publisher","DOI":"10.1063\/5.0306597","volume":"139","author":"C Wang","year":"2026","unstructured":"Wang C, Li S, Zeng Z, Wang A, Wang S, Li C, et al. A triple-axis hybrid-linearity selective gradient field system design in magnetic hyperthermia: providing a spheroidal shaped field-free region. J Appl Phys. 2026;139:085101. https:\/\/doi.org\/10.1063\/5.0306597.","journal-title":"J Appl Phys"},{"issue":"1","key":"1633_CR94","doi-asserted-by":"publisher","DOI":"10.1080\/02656736.2023.2272067","volume":"40","author":"H Carlton","year":"2023","unstructured":"Carlton H, Weber M, Peters M, Arepally N, Lad YS, Jaswal A, et al. Hyper: pre-clinical device for spatially-confined magnetic particle hyperthermia. Int J Hyperth. 2023;40(1):085101. https:\/\/doi.org\/10.1080\/02656736.2023.2272067.","journal-title":"Int J Hyperth"}],"container-title":["BioMedical Engineering OnLine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12938-026-01633-3","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12938-026-01633-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12938-026-01633-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,7]],"date-time":"2026-10-07T09:35:38Z","timestamp":1791365738000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s12938-026-01633-3"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,10,7]]},"references-count":94,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["1633"],"URL":"https:\/\/doi.org\/10.1186\/s12938-026-01633-3","relation":{},"ISSN":["1475-925X"],"issn-type":[{"value":"1475-925X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,10,7]]},"assertion":[{"value":"22 August 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"20 September 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"7 October 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Not applicable.","order":1,"name":"Ethics","label":"Ethics approval and consent to participate","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable.","order":2,"name":"Ethics","label":"Consent for publication","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The author\u2019s own previously developed system (Y\u00f6ner et al.\u00a0[\n                      \n                      ]) is discussed in this review for technological context. To avoid a conflict of interest, this system was excluded from all ordinal scoring and ranking comparisons presented in this work.","order":3,"name":"Ethics","label":"Competing interests","group":{"name":"EthicsHeading","label":"Declarations"}}],"article-number":"111"}}