{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,23]],"date-time":"2026-04-23T00:37:50Z","timestamp":1776904670125,"version":"3.51.2"},"reference-count":12,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2024,8,7]],"date-time":"2024-08-07T00:00:00Z","timestamp":1722988800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2024,8,7]],"date-time":"2024-08-07T00:00:00Z","timestamp":1722988800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["World J Surg Onc"],"abstract":"<jats:title>Abstract<\/jats:title><jats:p>Contrast enhanced ultrasonography enables dynamic evaluation of the microvasculature down to the capillaries when using high resolution ultrasound probes. It\u2019s application in the evaluation of axillary lymph nodes in breast cancer patients with clinically negative axilla has been studied in 42 patients. The results of pre operative CEUS evaluation was correlated with histopathology status of axillary nodes after the harvesting of nodes during modified radical mastectomy or sentinel node biopsy. Heterogeneous enhancement with micro bubbles of the axillary nodes was found to be the most distinguishing criteria for malignant nodes.<\/jats:p>","DOI":"10.1186\/s12957-024-03419-0","type":"journal-article","created":{"date-parts":[[2024,8,7]],"date-time":"2024-08-07T03:32:42Z","timestamp":1723001562000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Evaluation of axillary lymph nodes in breast cancer patients with clinically negative axilla using contrast enhanced ultrasonography"],"prefix":"10.1186","volume":"22","author":[{"given":"Roshit","family":"Jain","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rahul","family":"Khanna","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ashish","family":"Verma","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shashi Prakash","family":"Mishra","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ram Niwas","family":"Meena","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Seema","family":"Khanna","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Siddharth","family":"Khanna","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2024,8,7]]},"reference":[{"issue":"2","key":"3419_CR1","doi-asserted-by":"publisher","first-page":"176","DOI":"10.1016\/j.ejca.2003.09.029","volume":"40","author":"RD Macmillan","year":"2004","unstructured":"Macmillan RD, Rampaul RS, Lewis S, Evans AJ. Preoperative ultrasound-guided node biopsy and sentinel node augmented node sample is best practice. Eur J Cancer. 2004;40(2):176\u20138.","journal-title":"Eur J Cancer"},{"key":"3419_CR2","doi-asserted-by":"publisher","first-page":"546","DOI":"10.1056\/NEJMoa012782","volume":"349","author":"U Veroneri","year":"2003","unstructured":"Veroneri U, Pagarelli E, Viale E, Luini A. A randomized comparasion of sentinel lymph node biopsy with routine axillary dissection in breast cancer. New Eng J Med. 2003;349:546\u201353.","journal-title":"New Eng J Med"},{"key":"3419_CR3","doi-asserted-by":"publisher","first-page":"29","DOI":"10.1186\/1477-7819-9-29","volume":"9","author":"R Khanna","year":"2011","unstructured":"Khanna R, Sharma AD, Khanna S, Shukla RC. Usefulness of ultrasonography for the evaluation of cervical lympadenopathy. World J Surg. 2011;9:29.","journal-title":"World J Surg"},{"key":"3419_CR4","doi-asserted-by":"publisher","first-page":"109311","DOI":"10.1016\/j.ejrad.2020.109311","volume":"132","author":"AN Moody","year":"2020","unstructured":"Moody AN, Haigh C, Chen Y, Sharma N. Does enhanced ultrasound (CEUS) of normal\/ benign axillary lymph nodes in patients with breast cancer identify significant axillary burden ? Eur J Radiol. 2020;132:109311.","journal-title":"Eur J Radiol"},{"key":"3419_CR5","doi-asserted-by":"crossref","unstructured":"Fang C, Anupundi SA, Back SJ, Frauice D et al. Contrast enhanced ultrasound of benign and malignant liver lesions in children. Pediatric Radiology. 2021; Si (12): 2181\u20132197.","DOI":"10.1007\/s00247-021-04976-2"},{"key":"3419_CR6","doi-asserted-by":"publisher","first-page":"3890","DOI":"10.1016\/j.ejrad.2012.09.004","volume":"81","author":"J Du","year":"2012","unstructured":"Du J, Wang L, Wan CF, et al. Differentiating benign from malignant solid breast lesions: combined utility of conventional ultrasound and contrast enhanced ultrasound in comparison with magnetic resonance imaging. Eur J Radiol. 2012;81:3890\u20139.","journal-title":"Eur J Radiol"},{"key":"3419_CR7","doi-asserted-by":"publisher","first-page":"610","DOI":"10.4329\/wjr.v8.i6.610","volume":"8","author":"J Luo","year":"2016","unstructured":"Luo J, Chen JD, Chen Q, Yue LX, et al. Contrast enhanced ultrasound improved performance of breast imaging reporting and data system evaluation of critical breast lesions. World J Radio. 2016;8:610.","journal-title":"World J Radio"},{"key":"3419_CR8","first-page":"1","volume":"9999","author":"SC Lee","year":"2018","unstructured":"Lee SC, Tchelepi, Enant E, Derai B, et al. Contrast enhanced ultrasound imaging of breast masses. J Ultrasound Med. 2018;9999:1\u201315.","journal-title":"J Ultrasound Med"},{"key":"3419_CR9","doi-asserted-by":"publisher","first-page":"48","DOI":"10.1016\/j.ejrad.2015.10.017","volume":"85","author":"Y Wang","year":"2016","unstructured":"Wang Y, Fan W, Zhao S, et al. Qualitative, quantitative and combination score systems in differential diagnosis of breast lesions by contrast enhanced ultrasound. Eur J Radiol. 2016;85:48\u201354.","journal-title":"Eur J Radiol"},{"key":"3419_CR10","doi-asserted-by":"publisher","first-page":"2095","DOI":"10.7863\/ultra.15.10005","volume":"35","author":"X Ma","year":"2016","unstructured":"Ma X, Liu R, Zhu C, Zhang J, Ling W. Diagnostic value of contrast enhanced sonography for differentiation of breast lesions: a meta analysis. J Ultrasound Med. 2016;35:2095\u2013102.","journal-title":"J Ultrasound Med"},{"key":"3419_CR11","doi-asserted-by":"publisher","first-page":"919","DOI":"10.1016\/j.ultrasmedbio.2018.01.022","volume":"44","author":"Q Li","year":"2018","unstructured":"Li Q, Hu M, Chen Z, et al. Meta analysis: contrast enhanced ultrasound versus conventional ultrasound for differentiation of benign and malignant breast lesions. Ultrasound Med Biol. 2018;44:919\u201329.","journal-title":"Ultrasound Med Biol"},{"key":"3419_CR12","doi-asserted-by":"publisher","first-page":"687","DOI":"10.1016\/j.crad.2011.11.009","volume":"67","author":"AR Sever","year":"2012","unstructured":"Sever AR, Mills P, Jones SE, Mali W, Jones PA. Sentinel node identification using microbubbles and contrast enhanced ultrasonography. Clin Radiol. 2012;67:687\u201394.","journal-title":"Clin Radiol"}],"container-title":["World Journal of Surgical Oncology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12957-024-03419-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12957-024-03419-0\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12957-024-03419-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,8,7]],"date-time":"2024-08-07T03:33:26Z","timestamp":1723001606000},"score":1,"resource":{"primary":{"URL":"https:\/\/wjso.biomedcentral.com\/articles\/10.1186\/s12957-024-03419-0"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,8,7]]},"references-count":12,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2024,12]]}},"alternative-id":["3419"],"URL":"https:\/\/doi.org\/10.1186\/s12957-024-03419-0","relation":{},"ISSN":["1477-7819"],"issn-type":[{"value":"1477-7819","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,8,7]]},"assertion":[{"value":"11 September 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"20 May 2024","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"7 August 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"N\/A.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"There are no conflicts of interests.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"211"}}