{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2022,12,24]],"date-time":"2022-12-24T05:59:36Z","timestamp":1671861576989},"reference-count":20,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2022,12,23]],"date-time":"2022-12-23T00:00:00Z","timestamp":1671753600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,12,23]],"date-time":"2022-12-23T00:00:00Z","timestamp":1671753600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Cost Eff Resour Alloc"],"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Objectives<\/jats:title>\n                <jats:p>Surgical lung resection involves a critical task of stapled ligation and transection of major vascular structures and tissue, which may lead to bleeding and complications. A newer powered stapling system with Gripping Surface Technology (GST) was introduced to account for tissue movements. This study aimed to examine the real-world effectiveness of GST system on intraoperative and postoperative outcomes of pulmonary resection.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>A retrospective analysis was conducted using the electronic medical records of Sichuan Provincial People\u2019s Hospital between July 2020 and March 2021 in China. Patients who underwent their first procedures of single-port lobectomy or multi-port segmentectomy by video-assisted thoracoscopic surgery were identified and grouped as GST group or manual stapler group (manual group) by the stapler types. The intraoperative outcomes such as bleeding rate, blood loss volume, and intervention rate at the staple line (including intraoperative pressure, suture, and electrocoagulation) were documented by trained nurses during the surgery. Propensity score matching was performed between the two groups, controlling forage, BMI, smoking history, history of surgery, complications, and level of complexity of pneumonectomy.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>A total of 108 matched patients were included in the analysis (54 in the GST group and 54 in the manual group). GST group had lower risks for intraoperative bleeding (22.8% vs 51.9%; p\u2009=\u20090.003) and intraoperative interventions (31.5% vs 55.6%; p\u2009=\u20090.02), compared to the manual group. A decrease in the intraoperative blood loss was observed in the GST group, but not statistically significant (134.39\u2009\u00b1\u200952.82\u00a0ml vs 158.11\u2009\u00b1\u200973.14\u00a0ml, p\u2009=\u20090.102). The use of NEOVEIL (reinforcement material to prevent air leakage from the staple line) intraoperatively during surgery was significantly lower in the GST group (24.1%) than in the manual group (50%, p\u2009=\u20090.01).<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusion<\/jats:title>\n                <jats:p>The GST system was associated with better intraoperative outcomes in clinical practice in China.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s12962-022-00398-5","type":"journal-article","created":{"date-parts":[[2022,12,23]],"date-time":"2022-12-23T15:03:12Z","timestamp":1671807792000},"update-policy":"http:\/\/dx.doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Powered stapling system with gripping surface technology for pulmonary resection of lung cancer: real-world clinical effectiveness"],"prefix":"10.1186","volume":"20","author":[{"given":"Chongzhi","family":"Gan","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Fuchun","family":"Zeng","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Wei","family":"Cong","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tiange","family":"Tang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Gang","family":"Feng","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2022,12,23]]},"reference":[{"issue":"12","key":"398_CR1","doi-asserted-by":"publisher","first-page":"1749","DOI":"10.1001\/jamaoncol.2019.2996","volume":"5","author":"C Fitzmaurice","year":"2019","unstructured":"Fitzmaurice C, Abate D, Abbasi N, Abbastabar H, Abd-Allah F, Abdel-Rahman O, et al. Global, regional, and national cancer incidence, mortality, years of life lost, years lived with disability, and disability-adjusted life-years for 29 cancer groups, 1990 to 2017: a systematic analysis for the global burden of disease study. JAMA Oncol. 2019;5(12):1749\u201368.","journal-title":"JAMA Oncol"},{"issue":"1","key":"398_CR2","doi-asserted-by":"publisher","first-page":"3","DOI":"10.1111\/1759-7714.12916","volume":"10","author":"M Cao","year":"2019","unstructured":"Cao M, Chen W. Epidemiology of lung cancer in China. Thorac Cancer. 2019;10(1):3\u20137.","journal-title":"Thorac Cancer"},{"issue":"Suppl 1","key":"398_CR3","doi-asserted-by":"publisher","first-page":"S21","DOI":"10.21037\/tlcr.2019.03.12","volume":"8","author":"M Parascandola","year":"2019","unstructured":"Parascandola M, Xiao L. Tobacco and the lung cancer epidemic in China. Transl Lung Cancer Res. 2019;8(Suppl 1):S21-s30.","journal-title":"Transl Lung Cancer Res"},{"issue":"1","key":"398_CR4","doi-asserted-by":"publisher","first-page":"79","DOI":"10.21147\/j.issn.1000-9604.2021.01.09","volume":"33","author":"C Liu","year":"2021","unstructured":"Liu C, Shi J, Wang H, Yan X, Wang L, Ren J, et al. Population-level economic burden of lung cancer in China: provisional prevalence-based estimations, 2017\u20132030. Chin J Cancer Res. 2021;33(1):79\u201392.","journal-title":"Chin J Cancer Res"},{"issue":"9","key":"398_CR5","doi-asserted-by":"publisher","first-page":"957","DOI":"10.1016\/j.ejso.2013.06.016","volume":"39","author":"FF Chen","year":"2013","unstructured":"Chen FF, Zhang D, Wang YL, Xiong B. Video-assisted thoracoscopic surgery lobectomy versus open lobectomy in patients with clinical stage I non-small cell lung cancer: a meta-analysis. Eur J Surg Oncol. 2013;39(9):957\u201363.","journal-title":"Eur J Surg Oncol"},{"issue":"1","key":"398_CR6","doi-asserted-by":"publisher","first-page":"189","DOI":"10.1186\/s13019-019-1021-9","volume":"14","author":"B B\u00e9dat","year":"2019","unstructured":"B\u00e9dat B, Abdelnour-Berchtold E, Perneger T, Licker MJ, Stefani A, Krull M, et al. Comparison of postoperative complications between segmentectomy and lobectomy by video-assisted thoracic surgery: a multicenter study. J Cardiothorac Surg. 2019;14(1):189.","journal-title":"J Cardiothorac Surg"},{"issue":"23","key":"398_CR7","doi-asserted-by":"publisher","first-page":"712","DOI":"10.21037\/atm.2019.11.142","volume":"7","author":"L Liu","year":"2019","unstructured":"Liu L, Mei J, He J, Demmy TL, Gao S, Li S, et al. International expert consensus on the management of bleeding during VATS lung surgery. Ann Transl Med. 2019;7(23):712.","journal-title":"Ann Transl Med"},{"issue":"8","key":"398_CR8","doi-asserted-by":"publisher","first-page":"5023","DOI":"10.21037\/jtd.2018.07.42","volume":"10","author":"B B\u00e9dat","year":"2018","unstructured":"B\u00e9dat B, Abdelnour-Berchtold E, Krueger T, Perentes JY, Ris HB, Triponez F, et al. Clinical outcome and risk factors for complications after pulmonary segmentectomy by video-assisted thoracoscopic surgery: results of an initial experience. J Thorac Dis. 2018;10(8):5023\u20139.","journal-title":"J Thorac Dis"},{"key":"398_CR9","first-page":"41","volume":"13","author":"Y Tsunezuka","year":"2020","unstructured":"Tsunezuka Y, Tanaka N, Fujimori H. The impact of endoscopic stapler selection on bleeding at the vascular stump in pulmonary artery transection. Med Devices (Auckl). 2020;13:41\u20137.","journal-title":"Med Devices (Auckl)"},{"issue":"3","key":"398_CR10","doi-asserted-by":"publisher","first-page":"749","DOI":"10.1016\/0003-4975(93)90971-J","volume":"56","author":"TE Acuff","year":"1993","unstructured":"Acuff TE, Mack MJ, Landreneau RJ, Hazelrigg SR. Role of mechanical stapling devices in thoracoscopic pulmonary resection. Ann Thorac Surg. 1993;56(3):749\u201351.","journal-title":"Ann Thorac Surg"},{"issue":"2","key":"398_CR11","doi-asserted-by":"publisher","first-page":"20","DOI":"10.21037\/jovs.2017.01.03","volume":"3","author":"MO \u00d6zyurtkan","year":"2017","unstructured":"\u00d6zyurtkan MO, Kaba E, Toker A. Technological innovation in video-assisted thoracic surgery. J Vis Surg. 2017;3(2):20.","journal-title":"J Vis Surg"},{"issue":"12","key":"398_CR12","doi-asserted-by":"publisher","first-page":"5352","DOI":"10.21037\/jtd.2017.11.34","volume":"9","author":"H Kuroda","year":"2017","unstructured":"Kuroda H, Yoshida T, Sakao Y. A powered vascular staple for the application of segmental bronchial closure in thoracoscopic anatomic segmentectomy. J Thorac Dis. 2017;9(12):5352\u20134.","journal-title":"J Thorac Dis"},{"issue":"5","key":"398_CR13","doi-asserted-by":"publisher","first-page":"707","DOI":"10.1007\/s12325-018-0679-z","volume":"35","author":"DL Miller","year":"2018","unstructured":"Miller DL, Roy S, Kassis ES, Yadalam S, Ramisetti S, Johnston SS. Impact of powered and tissue-specific endoscopic stapling technology on clinical and economic outcomes of video-assisted thoracic surgery lobectomy procedures: a retrospective, observational study. Adv Ther. 2018;35(5):707\u201323.","journal-title":"Adv Ther"},{"issue":"4","key":"398_CR14","doi-asserted-by":"publisher","first-page":"423","DOI":"10.1080\/13696998.2017.1296453","volume":"20","author":"S Roy","year":"2017","unstructured":"Roy S, Yoo A, Yadalam S, Fegelman EJ, Kalsekar I, Johnston SS. Comparison of economic and clinical outcomes between patients undergoing laparoscopic bariatric surgery with powered versus manual endoscopic surgical staplers. J Med Econ. 2017;20(4):423\u201333.","journal-title":"J Med Econ"},{"issue":"12","key":"398_CR15","doi-asserted-by":"publisher","first-page":"1274","DOI":"10.1080\/13696998.2019.1634081","volume":"22","author":"SY Park","year":"2019","unstructured":"Park SY, Kim DJ, Mo Nam C, Park G, Byun G, Park H, et al. Clinical and economic benefits associated with the use of powered and tissue-specific endoscopic staplers among the patients undergoing thoracoscopic lobectomy for lung cancer. J Med Econ. 2019;22(12):1274\u201380.","journal-title":"J Med Econ"},{"issue":"5","key":"398_CR16","doi-asserted-by":"publisher","first-page":"489","DOI":"10.1089\/lap.2016.0513","volume":"27","author":"E Fegelman","year":"2017","unstructured":"Fegelman E, Knippenberg S, Schwiers M, Stefanidis D, Gersin KS, Scott JD, et al. Evaluation of a powered stapler system with gripping surface technology on surgical interventions required during laparoscopic sleeve gastrectomy. J Laparoendosc Adv Surg Tech. 2017;27(5):489\u201394.","journal-title":"J Laparoendosc Adv Surg Tech"},{"key":"398_CR17","doi-asserted-by":"publisher","first-page":"1","DOI":"10.9734\/BJMMR\/2016\/30153","volume":"18","author":"M Kimura","year":"2016","unstructured":"Kimura M, Tanaka H, Hato M, Taniwaki S, Shibata Y, Mizuno K, et al. Evaluation of a new stapler with unique surface gripping technology. Br J Med Med Res. 2016;18:1\u20136.","journal-title":"Br J Med Med Res"},{"key":"398_CR18","first-page":"195","volume":"13","author":"L Rawlins","year":"2020","unstructured":"Rawlins L, Johnson BH, Johnston SS, Elangovanraaj N, Bhandari M, Cohen RV, et al. Comparative effectiveness assessment of two powered surgical stapling platforms in laparoscopic sleeve gastrectomy: a retrospective matched study. Med Devices (Auckl). 2020;13:195\u2013204.","journal-title":"Med Devices (Auckl)"},{"issue":"3","key":"398_CR19","first-page":"232","volume":"60","author":"M Murata","year":"2011","unstructured":"Murata M, Umeda M, Takeuchi J, Suzuki H, Shibuya Y, Shigeta T, et al. Application of polyglycolic acid sheet (Neoveil\u00ae) and fibrin glue spray (Bolheal\u00ae) for open wounds in oral surgery. J Jpn Stomatol Soc. 2011;60(3):232\u20139.","journal-title":"J Jpn Stomatol Soc"},{"issue":"4","key":"398_CR20","doi-asserted-by":"publisher","first-page":"582","DOI":"10.1007\/s00595-020-02154-9","volume":"51","author":"W Shigeeda","year":"2021","unstructured":"Shigeeda W, Deguchi H, Tomoyasu M, Kudo S, Kaneko Y, Kanno H, et al. Utility of the powered stapler for radical pulmonary resection: a propensity score-matched analysis. Surg Today. 2021;51(4):582\u20138.","journal-title":"Surg Today"}],"container-title":["Cost Effectiveness and Resource Allocation"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12962-022-00398-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12962-022-00398-5\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12962-022-00398-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,12,23]],"date-time":"2022-12-23T15:07:41Z","timestamp":1671808061000},"score":1,"resource":{"primary":{"URL":"https:\/\/resource-allocation.biomedcentral.com\/articles\/10.1186\/s12962-022-00398-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,12,23]]},"references-count":20,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2022,12]]}},"alternative-id":["398"],"URL":"https:\/\/doi.org\/10.1186\/s12962-022-00398-5","relation":{},"ISSN":["1478-7547"],"issn-type":[{"value":"1478-7547","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,12,23]]},"assertion":[{"value":"2 May 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"4 November 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"23 December 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The study protocol was reviewed and approved by the Ethics Review Board of the SPPH. The consents to participate from patients were exempted. (See ethical approval in supplementary materials).","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval and consent to participate"}},{"value":"All authors understand that the information will be published without child or ward\u2019s\/relative\u2019s (circle as appropriate) name attached, but that full anonymity cannot be guaranteed. All authors understand that the text and any pictures or videos published in the article will be freely available on the internet and may be seen by the general public. The pictures, videos and text may also appear on other websites or in print, may be translated into other languages or used for commercial purposes. All authors have been offered the opportunity to read the manuscript.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"All authors have no competing interests as defined by BMC, or other interests that might be perceived to influence the results and\/or discussion reported in this paper.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"72"}}