{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T00:36:07Z","timestamp":1790814967382,"version":"4.1.0"},"reference-count":38,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2021,1,5]],"date-time":"2021-01-05T00:00:00Z","timestamp":1609804800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2021,1,5]],"date-time":"2021-01-05T00:00:00Z","timestamp":1609804800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Projekt DEAL"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Transl Med"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>\n                      Treating severe forms of the acute respiratory distress syndrome and cardiac failure, extracorporeal membrane oxygenation (ECMO) has become an established therapeutic option. Neonatal or pediatric patients receiving ECMO, and patients undergoing extracorporeal CO\n                      <jats:sub>2<\/jats:sub>\n                      removal (ECCO\n                      <jats:sub>2<\/jats:sub>\n                      R) represent low-flow applications of the technology, requiring lower blood flow than conventional ECMO. Centrifugal blood pumps as a core element of modern ECMO therapy present favorable operating characteristics in the high blood flow range (4\u00a0L\/min\u20138\u00a0L\/min). However, during low-flow applications in the range of 0.5\u00a0L\/min\u20132\u00a0L\/min, adverse events such as increased hemolysis, platelet activation and bleeding complications are reported frequently.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>In this study, the hemolysis of the centrifugal pump DP3 is evaluated both in vitro and in silico, comparing the low-flow operation at 1\u00a0L\/min to the high-flow operation at 4\u00a0L\/min.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Increased hemolysis occurs at low-flow, both in vitro and in silico. The in-vitro experiments present a sixfold higher relative increased hemolysis at low-flow. Compared to high-flow operation, a more than 3.5-fold increase in blood recirculation within the pump head can be observed in the low-flow range in silico.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>\n                      This study highlights the underappreciated hemolysis in centrifugal pumps within the low-flow range, i.e. during pediatric ECMO or ECCO\n                      <jats:sub>2<\/jats:sub>\n                      R treatment. The in-vitro results of hemolysis and the in-silico computational fluid dynamic simulations of flow paths within the pumps raise awareness about blood damage that occurs when using centrifugal pumps at low-flow operating points. These findings underline the urgent need for a specific pump optimized for low-flow treatment. Due to the inherent problems of available centrifugal pumps in the low-flow range, clinicians should use the current centrifugal pumps with caution, alternatively other pumping principles such as positive displacement pumps may be discussed in the future.\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s12967-020-02599-z","type":"journal-article","created":{"date-parts":[[2021,1,5]],"date-time":"2021-01-05T06:03:46Z","timestamp":1609826626000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":89,"title":["Hemolysis at low blood flow rates: in-vitro and in-silico evaluation of a centrifugal blood pump"],"prefix":"10.1186","volume":"19","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-4613-5053","authenticated-orcid":false,"given":"Malte","family":"Sch\u00f6ps","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sascha H.","family":"Gro\u00df-Hardt","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Thomas","family":"Schmitz-Rode","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ulrich","family":"Steinseifer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daniel","family":"Brodie","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Johanna C.","family":"Clauser","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christian","family":"Karagiannidis","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2021,1,5]]},"reference":[{"key":"2599_CR1","doi-asserted-by":"publisher","first-page":"557","DOI":"10.1001\/jama.2019.9302","volume":"322","author":"D Brodie","year":"2019","unstructured":"Brodie D, Slutsky AS, Combes A. Extracorporeal life support for adults with respiratory failure and related indications: a review. JAMA. 2019;322:557\u201368. https:\/\/doi.org\/10.1001\/jama.2019.9302.","journal-title":"JAMA"},{"key":"2599_CR2","doi-asserted-by":"publisher","DOI":"10.1016\/S2213-2600(20)30328-3","author":"M Schmidt","year":"2020","unstructured":"Schmidt M, Hajage D, Lebreton G, Monsel A, Voiriot G, Levy D, et al. Extracorporeal membrane oxygenation for severe acute respiratory distress syndrome associated with COVID-19: a retrospective cohort study. Lancet Respir Med. 2020. https:\/\/doi.org\/10.1016\/S2213-2600(20)30328-3.","journal-title":"Lancet Respir Med"},{"key":"2599_CR3","doi-asserted-by":"publisher","first-page":"592","DOI":"10.1007\/s00134-019-05567-4","volume":"45","author":"A Combes","year":"2019","unstructured":"Combes A, Fanelli V, Pham T, Ranieri VM. Feasibility and safety of extracorporeal CO2 removal to enhance protective ventilation in acute respiratory distress syndrome: the SUPERNOVA study. Intensive Care Med. 2019;45:592\u2013600. https:\/\/doi.org\/10.1007\/s00134-019-05567-4.","journal-title":"Intensive Care Med"},{"key":"2599_CR4","doi-asserted-by":"publisher","first-page":"2251","DOI":"10.1001\/jama.2018.14276","volume":"320","author":"EC Goligher","year":"2018","unstructured":"Goligher EC, Tomlinson G, Hajage D, Wijeysundera DN, Fan E, J\u00fcni P, et al. Extracorporeal membrane oxygenation for severe acute respiratory distress syndrome and posterior probability of mortality benefit in a post hoc Bayesian analysis of a randomized clinical trial. JAMA. 2018;320:2251\u20139. https:\/\/doi.org\/10.1001\/jama.2018.14276.","journal-title":"JAMA"},{"key":"2599_CR5","doi-asserted-by":"publisher","first-page":"512","DOI":"10.21037\/atm.2019.09.27","volume":"7","author":"S Erickson","year":"2019","unstructured":"Erickson S. Extra-corporeal membrane oxygenation in paediatric acute respiratory distress syndrome: overrated or underutilized? Ann Transl Med. 2019;7:512. https:\/\/doi.org\/10.21037\/atm.2019.09.27.","journal-title":"Ann Transl Med."},{"key":"2599_CR6","doi-asserted-by":"publisher","first-page":"1177","DOI":"10.1097\/PCC.0000000000002103","volume":"20","author":"CP O\u2019Halloran","year":"2019","unstructured":"O\u2019Halloran CP, Thiagarajan RR, Yarlagadda VV, Barbaro RP, Nasr VG, Rycus P, et al. Outcomes of infants supported with extracorporeal membrane oxygenation using centrifugal versus roller pumps: an analysis from the extracorporeal life support organization registry. Pediatr Crit Care Med. 2019;20:1177\u201384. https:\/\/doi.org\/10.1097\/PCC.0000000000002103.","journal-title":"Pediatr Crit Care Med."},{"key":"2599_CR7","doi-asserted-by":"publisher","first-page":"135","DOI":"10.1186\/s13054-019-2404-y","volume":"23","author":"C Karagiannidis","year":"2019","unstructured":"Karagiannidis C, Strassmann S, Schwarz S, Merten M, Fan E, Beck J, et al. Control of respiratory drive by extracorporeal CO2 removal in acute exacerbation of COPD breathing on non-invasive NAVA. Crit Care. 2019;23:135. https:\/\/doi.org\/10.1186\/s13054-019-2404-y.","journal-title":"Crit Care"},{"key":"2599_CR8","doi-asserted-by":"publisher","first-page":"1437","DOI":"10.1007\/s00134-016-4452-y","volume":"42","author":"S Braune","year":"2016","unstructured":"Braune S, Sieweke A, Brettner F, Staudinger T, Joannidis M, Verbrugge S, et al. The feasibility and safety of extracorporeal carbon dioxide removal to avoid intubation in patients with COPD unresponsive to noninvasive ventilation for acute hypercapnic respiratory failure (ECLAIR study): multicentre case-control study. Intensive Care Med. 2016;42:1437\u201344. https:\/\/doi.org\/10.1007\/s00134-016-4452-y.","journal-title":"Intensive Care Med"},{"key":"2599_CR9","doi-asserted-by":"publisher","DOI":"10.1016\/j.jtcvs.2019.06.084","author":"M Granegger","year":"2019","unstructured":"Granegger M, Thamsen B, Schl\u00f6glhofer T, Lach S, Escher A, Haas T, et al. Blood trauma potential of the HeartWare Ventricular Assist Device in pediatric patients. J Thorac Cardiovasc Surg. 2019. https:\/\/doi.org\/10.1016\/j.jtcvs.2019.06.084.","journal-title":"J Thorac Cardiovasc Surg"},{"key":"2599_CR10","doi-asserted-by":"publisher","first-page":"348","DOI":"10.1186\/s13054-019-2622-3","volume":"23","author":"S Gross-Hardt","year":"2019","unstructured":"Gross-Hardt S, Hesselmann F, Arens J, Steinseifer U, Vercaemst L, Windisch W, et al. Low-flow assessment of current ECMO\/ECCO2R rotary blood pumps and the potential effect on hemocompatibility. Crit Care. 2019;23:348. https:\/\/doi.org\/10.1186\/s13054-019-2622-3.","journal-title":"Crit Care."},{"key":"2599_CR11","doi-asserted-by":"publisher","first-page":"496","DOI":"10.1097\/mat.0000000000000243","volume":"61","author":"I Halaweish","year":"2015","unstructured":"Halaweish I, Cole A, Cooley E, Lynch WR, Haft JW. Roller and centrifugal pumps: a retrospective comparison of bleeding complications in extracorporeal membrane oxygenation. ASAIO J. 2015;61:496\u2013501. https:\/\/doi.org\/10.1097\/mat.0000000000000243.","journal-title":"ASAIO J."},{"key":"2599_CR12","doi-asserted-by":"publisher","first-page":"662","DOI":"10.1177\/0267659116651483","volume":"31","author":"BC Shade","year":"2016","unstructured":"Shade BC, Schiavo K, Rosenthal T, Connelly JT, Melchior RW. A single center\u2019s conversion from roller pump to centrifugal pump technology in extracorporeal membrane oxygenation. Perfusion. 2016;31:662\u20137. https:\/\/doi.org\/10.1177\/0267659116651483.","journal-title":"Perfusion."},{"key":"2599_CR13","doi-asserted-by":"publisher","first-page":"1195","DOI":"10.1097\/PCC.0000000000002112","volume":"20","author":"HJ Dalton","year":"2019","unstructured":"Dalton HJ, Hoskote A. There and back again: roller pumps versus centrifugal technology in infants on extracorporeal membrane oxygenation. Pediatr Crit Care Med. 2019;20:1195\u20136. https:\/\/doi.org\/10.1097\/PCC.0000000000002112.","journal-title":"Pediatr Crit Care Med."},{"key":"2599_CR14","doi-asserted-by":"publisher","first-page":"217","DOI":"10.1051\/ject\/201446217","volume":"46","author":"JP Sulkowski","year":"2014","unstructured":"Sulkowski JP, Cooper JN, Pearson EG, Connelly JT, Rintoul N, Kilbaugh TJ, et al. Hemolysis-associated nitric oxide dysregulation during extracorporeal membrane oxygenation. J Extra-Corporeal Technol. 2014;46:217\u201323.","journal-title":"J Extra-Corporeal Technol."},{"key":"2599_CR15","doi-asserted-by":"publisher","first-page":"51","DOI":"10.1186\/s40635-019-0264-z","volume":"7","author":"KK Ki","year":"2019","unstructured":"Ki KK, Passmore MR, Chan CHH, Malfertheiner MV, Fanning JP, Bouquet M, et al. Low flow rate alters haemostatic parameters in an ex vivo extracorporeal membrane oxygenation circuit. Intensive Care Med Exp. 2019;7:51. https:\/\/doi.org\/10.1186\/s40635-019-0264-z.","journal-title":"Intensive Care Med Exp."},{"key":"2599_CR16","doi-asserted-by":"publisher","first-page":"1002","DOI":"10.2478\/s11536-012-0005-0","volume":"7","author":"L Bezuska","year":"2012","unstructured":"Bezuska L, Lebetkevicius V, Lankutis K, Tarutis V. Successful experience with Levitronix PediVAS for management of acute heart failure after Fontan surgery. Open Med. 2012;7:1002. https:\/\/doi.org\/10.2478\/s11536-012-0005-0.","journal-title":"Open Med."},{"key":"2599_CR17","doi-asserted-by":"publisher","first-page":"23","DOI":"10.1097\/01.mat.0000247043.18115.f7","volume":"53","author":"J Zhang","year":"2007","unstructured":"Zhang J, Koert A, Gellman B, Gempp TM, Dasse KA, Gilbert RJ, et al. Optimization of a miniature Maglev ventricular assist device for pediatric circulatory support. ASAIO J. 2007;53:23\u201331. https:\/\/doi.org\/10.1097\/01.mat.0000247043.18115.f7.","journal-title":"ASAIO J."},{"key":"2599_CR18","doi-asserted-by":"publisher","first-page":"516","DOI":"10.1097\/mat.0b013e31822e2535","volume":"57","author":"CA Johnson","year":"2011","unstructured":"Johnson CA, Shankarraman V, Wearden PD, Kocyildirim E, Maul TM, Marks JD, et al. Platelet activation after implantation of the Levitronix PediVAS in the ovine model. ASAIO J. 2011;57:516\u201321. https:\/\/doi.org\/10.1097\/mat.0b013e31822e2535.","journal-title":"ASAIO J."},{"key":"2599_CR19","doi-asserted-by":"publisher","first-page":"263","DOI":"10.1007\/s13239-011-0063-5","volume":"2","author":"TM Maul","year":"2011","unstructured":"Maul TM, Kocyildirim E, Marks JD, Bengston SG, Olia SE, Callahan PM, et al. Pre-clinical implants of the Levitronix PediVAS\u00ae pediatric ventricular assist device\u2014strategy for regulatory approval. Cardiovasc Eng Technol. 2011;2:263\u201375. https:\/\/doi.org\/10.1007\/s13239-011-0063-5.","journal-title":"Cardiovasc Eng Technol."},{"key":"2599_CR20","doi-asserted-by":"publisher","unstructured":"F04 Committee. Standard Practice for Assessment of Hemolysis in Continuous Flow Blood Pumps 2017. West Conshohocken, PA: ASTM International. https:\/\/doi.org\/10.1520\/f1841-97r17.","DOI":"10.1520\/f1841-97r17"},{"issue":"138","key":"2599_CR21","doi-asserted-by":"publisher","first-page":"188","DOI":"10.1055\/s-0032-1332822","volume":"2013","author":"C Karagiannidis","year":"1946","unstructured":"Karagiannidis C, Philipp A, Buchwald D. Extrakorporaler Gasaustausch. Dtsch Med Wochenschr. 1946;2013(138):188\u201391. https:\/\/doi.org\/10.1055\/s-0032-1332822.","journal-title":"Dtsch Med Wochenschr"},{"key":"2599_CR22","doi-asserted-by":"publisher","DOI":"10.1007\/978-3-642-17003-4","volume-title":"Leitfaden extrakorporale Zirkulation","author":"C Schmid","year":"2011","unstructured":"Schmid C, Philipp A. Leitfaden extrakorporale Zirkulation. Berlin: Springer, Berlin Heidelberg; 2011."},{"issue":"28","key":"2599_CR23","doi-asserted-by":"publisher","first-page":"132","DOI":"10.1299\/jsmebiofro.2017.28.1b32","volume":"2017","author":"K Adachi","year":"2017","unstructured":"Adachi K, Maruyama O, Yamane T. A suitable hemolysis index for low flow blood pumps. Proc JSME Conf Front Bioeng. 2017;2017(28):132. https:\/\/doi.org\/10.1299\/jsmebiofro.2017.28.1b32.","journal-title":"Proc JSME Conf Front Bioeng."},{"key":"2599_CR24","unstructured":"DIN 58931. H\u00e4matologie\u2014Bestimmung der H\u00e4moglobinkonzentration im Blut: Referenzmethode 08.2010. 10772 Berlin: Beuth Verlag GmbH."},{"key":"2599_CR25","doi-asserted-by":"publisher","first-page":"271","DOI":"10.1136\/jcp.49.4.271","volume":"49","author":"A Zwart","year":"1996","unstructured":"Zwart A, van Assendelft OW, Bull BS, England JM, Lewis SM, Zijlstra WG. Recommendations for reference method for haemoglobinometry in human blood (ICSH standard 1995) and specifications for international haemiglobinocyanide standard (4th edition). J Clin Pathol. 1996;49:271\u20134.","journal-title":"J Clin Pathol"},{"key":"2599_CR26","doi-asserted-by":"publisher","DOI":"10.1115\/1.4042043","author":"SH Gross-Hardt","year":"2018","unstructured":"Gross-Hardt SH, Boehning F, Steinseifer U, Schmitz-Rode T, Kaufmann T. Mesh sensitivity analysis for quantitative shear stress assessment in blood pumps using computational fluid dynamics. J Biomech Eng. 2018. https:\/\/doi.org\/10.1115\/1.4042043.","journal-title":"J Biomech Eng"},{"key":"2599_CR27","doi-asserted-by":"publisher","first-page":"565","DOI":"10.3233\/bir-1994-31505","volume":"31","author":"PD Ballyk","year":"1994","unstructured":"Ballyk PD, Steinman DA, Ethier CR. Simulation of non-Newtonian blood flow in an end-to-side anastomosis. Biorheology. 1994;31:565\u201386. https:\/\/doi.org\/10.3233\/bir-1994-31505.","journal-title":"Biorheology"},{"key":"2599_CR28","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.bpc.2010.07.002","volume":"153","author":"E Di Stasio","year":"2010","unstructured":"Di Stasio E, Cristofaro RD. The effect of shear stress on protein conformation: physical forces operating on biochemical systems: The case of von Willebrand factor. Biophys Chem. 2010;153:1\u20138. https:\/\/doi.org\/10.1016\/j.bpc.2010.07.002.","journal-title":"Biophys Chem"},{"key":"2599_CR29","doi-asserted-by":"publisher","first-page":"81002","DOI":"10.1115\/1.4007092","volume":"134","author":"KH Fraser","year":"2012","unstructured":"Fraser KH, Zhang T, Taskin ME, Griffith BP, Wu ZJ. A quantitative comparison of mechanical blood damage parameters in rotary ventricular assist devices: shear stress, exposure time and hemolysis index. J Biomech Eng. 2012;134:81002. https:\/\/doi.org\/10.1115\/1.4007092.","journal-title":"J Biomech Eng"},{"key":"2599_CR30","doi-asserted-by":"publisher","first-page":"S33","DOI":"10.1016\/S0049-3848(98)00158-3","volume":"92","author":"KS Sakariassen","year":"1998","unstructured":"Sakariassen KS, Holme PA, \u00d8rvim U, Marius Barstad R, Solum NO, Brosstad FR. Shear-induced platelet activation and platelet microparticle formation in native human blood. Thromb Res. 1998;92:S33\u201341. https:\/\/doi.org\/10.1016\/S0049-3848(98)00158-3.","journal-title":"Thromb Res"},{"key":"2599_CR31","doi-asserted-by":"publisher","first-page":"2","DOI":"10.1161\/01.RES.41.1.2","volume":"41","author":"SP Sutera","year":"1977","unstructured":"Sutera SP. Flow-induced trauma to blood cells. Circ Res. 1977;41:2\u20138. https:\/\/doi.org\/10.1161\/01.RES.41.1.2.","journal-title":"Circ Res"},{"key":"2599_CR32","first-page":"35","volume":"21","author":"CH Brown III","year":"1975","unstructured":"Brown CH III, Lemuth RF, Hellums JD, Leverett LB, Alfrey CP. Response of human platelets to shear stress. ASAIO J. 1975;21:35\u20139.","journal-title":"ASAIO J."},{"key":"2599_CR33","doi-asserted-by":"publisher","first-page":"677","DOI":"10.1111\/j.1525-1594.2007.00446.x","volume":"31","author":"Y Alemu","year":"2007","unstructured":"Alemu Y, Bluestein D. Flow-induced platelet activation and damage accumulation in a mechanical heart valve: numerical studies. Artif Organs. 2007;31:677\u201388. https:\/\/doi.org\/10.1111\/j.1525-1594.2007.00446.x.","journal-title":"Artif Organs"},{"key":"2599_CR34","doi-asserted-by":"publisher","first-page":"363","DOI":"10.1097\/mat.0b013e318254833b","volume":"58","author":"ME Taskin","year":"2012","unstructured":"Taskin ME, Fraser KH, Zhang T, Wu C, Griffith BP, Wu ZJ. Evaluation of Eulerian and Lagrangian models for hemolysis estimation. ASAIO J. 2012;58:363\u201372. https:\/\/doi.org\/10.1097\/mat.0b013e318254833b.","journal-title":"ASAIO J."},{"key":"2599_CR35","doi-asserted-by":"publisher","DOI":"10.1002\/biot.201900239","author":"M Sch\u00f6ps","year":"2020","unstructured":"Sch\u00f6ps M, Clauser JC, Menne MF, Fa\u00dfb\u00e4nder D, Schmitz-Rode T, Steinseifer U, Arens J. Ghost cells for mechanical circulatory support in-vitro testing: a novel large volume production. Biotechnol J. 2020. https:\/\/doi.org\/10.1002\/biot.201900239.","journal-title":"Biotechnol J."},{"key":"2599_CR36","doi-asserted-by":"publisher","first-page":"2338","DOI":"10.1182\/blood-2015-05-648030","volume":"126","author":"Q Da","year":"2015","unstructured":"Da Q, Teruya M, Guchhait P, Teruya J, Olson JS, Cruz MA. Free hemoglobin increases von Willebrand factor-mediated platelet adhesion in vitro: implications for circulatory devices. Blood. 2015;126:2338\u201341. https:\/\/doi.org\/10.1182\/blood-2015-05-648030.","journal-title":"Blood"},{"key":"2599_CR37","doi-asserted-by":"publisher","first-page":"e0124034","DOI":"10.1371\/journal.pone.0124034","volume":"10","author":"HR Omar","year":"2015","unstructured":"Omar HR, Mirsaeidi M, Socias S, Sprenker C, Caldeira C, Camporesi EM, Mangar D. Plasma free hemoglobin is an independent predictor of mortality among patients on extracorporeal membrane oxygenation support. PLoS ONE. 2015;10:e0124034. https:\/\/doi.org\/10.1371\/journal.pone.0124034.","journal-title":"PLoS ONE"},{"key":"2599_CR38","unstructured":"Bioanalytic GmbH. free Hemoglobin (fHb) Cyanohemiglobin Method: 2 Wavelength Method (540\/680\u00a0nm) acc. to Tapernon. Freiburg, Germany; 2019."}],"container-title":["Journal of Translational Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12967-020-02599-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12967-020-02599-z","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12967-020-02599-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,27]],"date-time":"2026-04-27T18:27:43Z","timestamp":1777314463000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s12967-020-02599-z"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,1,5]]},"references-count":38,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2021,12]]}},"alternative-id":["2599"],"URL":"https:\/\/doi.org\/10.1186\/s12967-020-02599-z","relation":{},"ISSN":["1479-5876"],"issn-type":[{"value":"1479-5876","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,1,5]]},"assertion":[{"value":"14 July 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"30 October 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"5 January 2021","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"28 April 2026","order":5,"name":"change_date","label":"Change Date","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Update","order":6,"name":"change_type","label":"Change Type","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Article updated to change the corresponding author\u2019s email id.","order":7,"name":"change_details","label":"Change Details","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The manuscript does not contain experiments using animals. Instead, porcine blood was obtained from a local slaughterhouse. The manuscript does not contain studies involving human participants, human data or human tissue.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"Conflict of interest and Source of Funding: \u201cDr. Brodie\u201d receives research support from ALung Technologies, he was previously on their medical advisory board. He has been on the medical advisory boards for Baxter, BREETHE, Xenios and Hemovent. The remaining authors declare no financial, consulting, institutional or commercial conflict of interest. All other authors declare that they have no competing interests.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"2"}}