{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,27]],"date-time":"2026-10-27T21:30:41Z","timestamp":1793136641818,"version":"4.5.0"},"reference-count":35,"publisher":"Elsevier BV","issue":"1","license":[{"start":{"date-parts":[[2016,12,1]],"date-time":"2016-12-01T00:00:00Z","timestamp":1480550400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2016,12,1]],"date-time":"2016-12-01T00:00:00Z","timestamp":1480550400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2017,4,3]],"date-time":"2017-04-03T00:00:00Z","timestamp":1491177600000},"content-version":"vor","delay-in-days":123,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/100000050","name":"National Heart, Lung, and Blood Institute","doi-asserted-by":"publisher","award":["R01HL127153"],"award-info":[{"award-number":["R01HL127153"]}],"id":[{"id":"10.13039\/100000050","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Cardiovascular Magnetic Resonance"],"published-print":{"date-parts":[[2016,12]]},"DOI":"10.1186\/s12968-017-0352-8","type":"journal-article","created":{"date-parts":[[2017,3,22]],"date-time":"2017-03-22T11:06:22Z","timestamp":1490180782000},"page":"40","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":36,"title":["4D MUSIC CMR: value-based imaging of neonates and infants with congenital heart disease"],"prefix":"10.1016","volume":"19","author":[{"given":"Kim-Lien","family":"Nguyen","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fei","family":"Han","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ziwu","family":"Zhou","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daniel Z.","family":"Brunengraber","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ihab","family":"Ayad","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daniel S.","family":"Levi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gary M.","family":"Satou","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Brian L.","family":"Reemtsen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Peng","family":"Hu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"J. Paul","family":"Finn","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1186\/s12968-017-0352-8_bib1","doi-asserted-by":"crossref","first-page":"1042","DOI":"10.1002\/mrm.25491","article-title":"Four-dimensional, multiphase, steady-state imaging with contrast enhancement (MUSIC) in the heart: A feasibility study in children","volume":"74","author":"Han","year":"2015","journal-title":"Magn Reson Med"},{"key":"10.1186\/s12968-017-0352-8_bib2","doi-asserted-by":"crossref","first-page":"837","DOI":"10.1148\/radiol.2433060155","article-title":"Contrast-enhanced MR angiography of the chest and abdomen with use of controlled apnea in children","volume":"243","author":"Saleh","year":"2007","journal-title":"Radiology"},{"key":"10.1186\/s12968-017-0352-8_bib3","doi-asserted-by":"crossref","first-page":"69","DOI":"10.1016\/j.amjcard.2004.03.033","article-title":"Clinical role, accuracy, and technical aspects of cardiovascular magnetic resonance imaging in infants","volume":"94","author":"Tsai-Goodman","year":"2004","journal-title":"Am J Cardiol"},{"key":"10.1186\/s12968-017-0352-8_bib4","doi-asserted-by":"crossref","first-page":"42","DOI":"10.1007\/s00247-014-3093-y","article-title":"High-field MR imaging in pediatric congenital heart disease: Initial results","volume":"45","author":"Nguyen","year":"2015","journal-title":"Pediatr Radiol"},{"key":"10.1186\/s12968-017-0352-8_bib5","doi-asserted-by":"crossref","first-page":"46","DOI":"10.1002\/jmri.20235","article-title":"First-pass contrast-enhanced magnetic resonance angiography in humans using ferumoxytol, a novel ultrasmall superparamagnetic iron oxide (USPIO)-based blood pool agent","volume":"21","author":"Li","year":"2005","journal-title":"J Magn Reson Imaging"},{"key":"10.1186\/s12968-017-0352-8_bib6","author":"US Food and Drug Administration"},{"key":"10.1186\/s12968-017-0352-8_bib7","article-title":"Self-gated 4D multiphase, steady-state imaging with contrast enhancement (MUSIC) using rotating cartesian K-space (ROCK): Validation in children with congenital heart disease","author":"Han","year":"2016","journal-title":"Magn Reson Med"},{"key":"10.1186\/s12968-017-0352-8_bib8","doi-asserted-by":"crossref","first-page":"375","DOI":"10.1002\/jmri.20969","article-title":"Measurement of signal-to-noise ratios in MR images: influence of multichannel coils, parallel imaging, and reconstruction filters","volume":"26","author":"Dietrich","year":"2007","journal-title":"J Magn Reson Imaging"},{"key":"10.1186\/s12968-017-0352-8_bib10","doi-asserted-by":"crossref","first-page":"107","DOI":"10.1148\/radiographics.20.1.g00ja24107","article-title":"MR angiography of the thoracic aorta with an electrocardiographically triggered breath-hold contrast-enhanced sequence","volume":"20","author":"Arpasi","year":"2000","journal-title":"Radiographics"},{"key":"10.1186\/s12968-017-0352-8_bib11","doi-asserted-by":"crossref","first-page":"522","DOI":"10.2214\/AJR.05.1467","article-title":"Quantitative analysis of ECG-gated high-resolution contrast-enhanced MR angiography of the thoracic aorta","volume":"188","author":"Groves","year":"2007","journal-title":"AJR Am J Roentgenol"},{"key":"10.1186\/s12968-017-0352-8_bib12","doi-asserted-by":"crossref","first-page":"163","DOI":"10.1161\/01.CIR.0000134282.35183.AD","article-title":"Operator-independent isotropic three-dimensional magnetic resonance imaging for morphology in congenital heart disease: a validation study","volume":"110","author":"Sorensen","year":"2004","journal-title":"Circulation"},{"key":"10.1186\/s12968-017-0352-8_bib13","doi-asserted-by":"crossref","first-page":"1265","DOI":"10.1007\/s00247-006-0314-z","article-title":"Three-dimensional morphological magnetic resonance imaging in infants and children with congenital heart disease","volume":"36","author":"Fenchel","year":"2006","journal-title":"Pediatr Radiol"},{"key":"10.1186\/s12968-017-0352-8_bib14","doi-asserted-by":"crossref","first-page":"1333","DOI":"10.1007\/s00247-009-1390-7","article-title":"Three-dimensional cine MRI in free-breathing infants and children with congenital heart disease","volume":"39","author":"Seeger","year":"2009","journal-title":"Pediatr Radiol"},{"key":"10.1186\/s12968-017-0352-8_bib15","doi-asserted-by":"crossref","first-page":"41","DOI":"10.1186\/1532-429X-15-41","article-title":"Cardiovascular magnetic resonance artefacts","volume":"15","author":"Ferreira","year":"2013","journal-title":"J Cardiovasc Magn Reson"},{"key":"10.1186\/s12968-017-0352-8_bib16","doi-asserted-by":"crossref","first-page":"1921","DOI":"10.1016\/j.ejrad.2015.06.030","article-title":"Congenital heart disease in adults: Quantitative and qualitative evaluation of IR FLASH and IR SSFP MRA techniques using a blood pool contrast agent in the steady state and comparison to first pass MRA","volume":"84","author":"Febbo","year":"2015","journal-title":"Eur J Radiol"},{"key":"10.1186\/s12968-017-0352-8_bib17","doi-asserted-by":"crossref","first-page":"7","DOI":"10.1186\/1532-429X-13-7","article-title":"Comprehensive 4D velocity mapping of the heart and great vessels by cardiovascular magnetic resonance","volume":"13","author":"Markl","year":"2011","journal-title":"J Cardiovasc Magn Reson"},{"issue":"6","key":"10.1186\/s12968-017-0352-8_bib18","doi-asserted-by":"crossref","first-page":"1355","DOI":"10.1002\/jmri.25106","article-title":"Comprehensive motion-compensated highly accelerated 4D flow MRI with ferumoxytol enhancement for pediatric congenital heart disease","volume":"43","author":"Cheng","year":"2016","journal-title":"J Magn Reson Imaging"},{"key":"10.1186\/s12968-017-0352-8_bib19","article-title":"Feasibility of ferumoxytol-enhanced neonatal and young infant cardiac MRI without general anesthesia","author":"Lai","year":"2016","journal-title":"J Magn Reson Imaging"},{"key":"10.1186\/s12968-017-0352-8_bib20","author":"AMAG Pharmaceuticals","year":"2014","journal-title":"Feraheme Drug Label"},{"key":"10.1186\/s12968-017-0352-8_bib21","doi-asserted-by":"crossref","first-page":"884","DOI":"10.1002\/jmri.24691","article-title":"Emerging applications for ferumoxytol as a contrast agent in MRI","volume":"41","author":"Bashir","year":"2015","journal-title":"J Magn Reson Imaging"},{"key":"10.1186\/s12968-017-0352-8_bib22","doi-asserted-by":"crossref","first-page":"796","DOI":"10.1016\/j.crad.2016.03.020","article-title":"Cardiovascular MRI with ferumoxytol","volume":"71","author":"Finn","year":"2016","journal-title":"Clin Radiol"},{"key":"10.1186\/s12968-017-0352-8_bib23","doi-asserted-by":"crossref","first-page":"91","DOI":"10.1097\/TP.0b013e318295464c","article-title":"Renal transplant imaging using magnetic resonance angiography with a nonnephrotoxic contrast agent","volume":"96","author":"Bashir","year":"2013","journal-title":"Transplantation"},{"key":"10.1186\/s12968-017-0352-8_bib24","first-page":"231","article-title":"A pilot investigation of new superparamagnetic iron oxide (ferumoxytol) as a contrast agent for cardiovascular MRI","volume":"11","author":"Prince","year":"2003","journal-title":"J Xray Sci Technol"},{"key":"10.1186\/s12968-017-0352-8_bib25","doi-asserted-by":"crossref","first-page":"515","DOI":"10.1007\/s00467-014-2953-x","article-title":"High-resolution, whole-body vascular imaging with ferumoxytol as an alternative to gadolinium agents in a pediatric chronic kidney disease cohort","volume":"30","author":"Nayak","year":"2015","journal-title":"Pediatr Nephrol"},{"key":"10.1186\/s12968-017-0352-8_bib26","doi-asserted-by":"crossref","first-page":"465","DOI":"10.1038\/ki.2008.496","article-title":"Ultrasmall superparamagnetic iron oxides (USPIOs): a future alternative magnetic resonance (MR) contrast agent for patients at risk for nephrogenic systemic fibrosis (NSF)?","volume":"75","author":"Neuwelt","year":"2009","journal-title":"Kidney Int"},{"key":"10.1186\/s12968-017-0352-8_bib27","doi-asserted-by":"crossref","first-page":"113","DOI":"10.1002\/jmri.24330","article-title":"Retrospective assessment of the utility of an iron-based agent for contrast-enhanced magnetic resonance venography in patients with endstage renal diseases","volume":"40","author":"Bashir","year":"2014","journal-title":"J Magn Reson Imaging"},{"key":"10.1186\/s12968-017-0352-8_bib28","doi-asserted-by":"crossref","first-page":"63","DOI":"10.1016\/j.avsg.2014.09.003","article-title":"Ferumoxytol-Enhanced Magnetic Resonance Angiography is a Feasible Method for the Clinical Evaluation of Lower Extremity Arterial Disease","volume":"29","author":"Walker","year":"2015","journal-title":"Ann Vasc Surg"},{"key":"10.1186\/s12968-017-0352-8_bib29","doi-asserted-by":"crossref","first-page":"772","DOI":"10.1148\/radiol.15150025","article-title":"Intracranial Gadolinium Deposition after Contrast-enhanced MR Imaging","volume":"275","author":"McDonald","year":"2015","journal-title":"Radiology"},{"key":"10.1186\/s12968-017-0352-8_bib30","doi-asserted-by":"crossref","first-page":"907","DOI":"10.1016\/S0140-6736(15)60865-0","article-title":"Iron deficiency anaemia","volume":"387","author":"Lopez","year":"2016","journal-title":"Lancet"},{"issue":"3","key":"10.1186\/s12968-017-0352-8_bib31","first-page":"804","article-title":"MRI with Ferumoxytol: A Single Center Experience of Safety Across the Age Spectrum","volume":"45","author":"Nguyen","year":"2017","journal-title":"J Magn Reson"},{"key":"10.1186\/s12968-017-0352-8_bib32","doi-asserted-by":"crossref","first-page":"152","DOI":"10.1016\/j.mri.2015.10.019","article-title":"Hemodynamic safety and efficacy of ferumoxytol as an intravenous contrast agents in pediatric patients and young adults","volume":"34","author":"Ning","year":"2016","journal-title":"Magn Reson Imaging"},{"key":"10.1186\/s12968-017-0352-8_bib33","doi-asserted-by":"crossref","first-page":"221","DOI":"10.1097\/RLI.0000000000000230","article-title":"Safety Report of Ferumoxytol for Magnetic Resonance Imaging in Children and Young Adults","volume":"51","author":"Muehe","year":"2016","journal-title":"Invest Radiol"},{"key":"10.1186\/s12968-017-0352-8_bib34","series-title":"Textbook of Clinical Pediatrics","author":"Elzouki AY","year":"2012"},{"key":"10.1186\/s12968-017-0352-8_bib35","doi-asserted-by":"crossref","first-page":"137","DOI":"10.1016\/j.clim.2005.10.012","article-title":"Innate cellular immune responses in newborns","volume":"118","author":"Marodi","year":"2006","journal-title":"Clin Immunol"},{"key":"10.1186\/s12968-017-0352-8_bib36","first-page":"1","article-title":"Is Infant Immunity Actively Suppressed or Immature?","volume":"2014","author":"Gervassi","year":"2014","journal-title":"Virol"}],"container-title":["Journal of Cardiovascular Magnetic Resonance"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s12968-017-0352-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1186\/s12968-017-0352-8\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1097664723010748?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1097664723010748?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s12968-017-0352-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,22]],"date-time":"2025-10-22T01:09:19Z","timestamp":1761095359000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1097664723010748"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,12]]},"references-count":35,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2016,12]]}},"alternative-id":["S1097664723010748"],"URL":"https:\/\/doi.org\/10.1186\/s12968-017-0352-8","relation":{},"ISSN":["1097-6647"],"issn-type":[{"value":"1097-6647","type":"print"}],"subject":[],"published":{"date-parts":[[2016,12]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"4D MUSIC CMR: value-based imaging of neonates and infants with congenital heart disease","name":"articletitle","label":"Article Title"},{"value":"Journal of Cardiovascular Magnetic Resonance","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1186\/s12968-017-0352-8","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2017 THE AUTHORS. Published by Elsevier Inc on behalf of the Society for Cardiovascular Magnetic Resonance","name":"copyright","label":"Copyright"}],"article-number":"40"}}