{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,30]],"date-time":"2026-10-30T18:25:49Z","timestamp":1793384749960,"version":"4.5.0"},"reference-count":30,"publisher":"Elsevier BV","issue":"1","license":[{"start":{"date-parts":[[2023,2,1]],"date-time":"2023-02-01T00:00:00Z","timestamp":1675209600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2023,2,1]],"date-time":"2023-02-01T00:00:00Z","timestamp":1675209600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2023,6,22]],"date-time":"2023-06-22T00:00:00Z","timestamp":1687392000000},"content-version":"vor","delay-in-days":141,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Cardiovascular Magnetic Resonance"],"published-print":{"date-parts":[[2023,2]]},"DOI":"10.1186\/s12968-023-00945-w","type":"journal-article","created":{"date-parts":[[2023,6,21]],"date-time":"2023-06-21T19:33:19Z","timestamp":1687375999000},"page":"35","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":7,"title":["A simplified method to correct saturation of arterial input function for cardiac magnetic resonance first-pass perfusion imaging: validation with simultaneously acquired PET"],"prefix":"10.1016","volume":"25","author":[{"given":"Ran","family":"Li","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Masoud","family":"Edalati","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David","family":"Muccigrosso","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jeffrey M.C.","family":"Lau","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Richard","family":"Laforest","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pamela K.","family":"Woodard","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2310-2996","authenticated-orcid":false,"given":"Jie","family":"Zheng","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1186\/s12968-023-00945-w_bib1","doi-asserted-by":"crossref","first-page":"221","DOI":"10.1016\/j.ccl.2004.02.005","article-title":"The coronary microcirculation in health and disease","volume":"22","author":"Wei","year":"2004","journal-title":"Cardiol Clin"},{"key":"10.1186\/s12968-023-00945-w_bib2","first-page":"230","article-title":"How to study coronary microvascular dysfunction and its clinic relevance","volume":"3","author":"L'Abbate","year":"2002","journal-title":"Ital Heart J"},{"issue":"10","key":"10.1186\/s12968-023-00945-w_bib3","doi-asserted-by":"crossref","first-page":"18","DOI":"10.1186\/1532-429X-10-18","article-title":"Myocardial first-pass perfusion cardiovascular magnetic resonance: history, theory, and current state of the art","volume":"28","author":"Gerber","year":"2008","journal-title":"J Cardiovasc Magn Reson"},{"key":"10.1186\/s12968-023-00945-w_bib4","doi-asserted-by":"crossref","first-page":"2","DOI":"10.1053\/j.sult.2005.10.001","article-title":"MRI of myocardial perfusion","volume":"27","author":"Jerosch-Herold","year":"2006","journal-title":"Semin Ultrasound CT MR"},{"key":"10.1186\/s12968-023-00945-w_bib5","doi-asserted-by":"crossref","first-page":"677","DOI":"10.1148\/radiol.2323030573","article-title":"Absolute myocardial perfusion in canines measured by using dual-bolus first-pass MR imaging","volume":"232","author":"Christian","year":"2004","journal-title":"Radiology"},{"key":"10.1186\/s12968-023-00945-w_bib6","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1186\/1532-429X-16-11","article-title":"Voxel-wise quantification of myocardial blood flow with cardiovascular magnetic resonance: effect of variations in methodology and validation with positron emission tomography","volume":"16","author":"Miller","year":"2014","journal-title":"J Cardiovasc Magn Reson"},{"key":"10.1186\/s12968-023-00945-w_bib7","doi-asserted-by":"crossref","first-page":"754","DOI":"10.1002\/jmri.24834","article-title":"Quantification of myocardial blood flow with dynamic perfusion 3.0 Tesla MRI: Validation with (15) O-water PET","volume":"42","author":"Tomiyama","year":"2015","journal-title":"J Magn Reson Imaging"},{"key":"10.1186\/s12968-023-00945-w_bib8","doi-asserted-by":"crossref","first-page":"1958","DOI":"10.1016\/j.jcmg.2018.12.022","article-title":"Automated pixel-wise quantitative myocardial perfusion mapping by cmr to detect obstructive coronary artery disease and coronary microvascular dysfunction: validation against invasive coronary physiology","volume":"12","author":"Kotecha","year":"2019","journal-title":"JACC Cardiovasc Imaging"},{"key":"10.1186\/s12968-023-00945-w_bib9","doi-asserted-by":"crossref","first-page":"296","DOI":"10.1002\/mrm.20160","article-title":"Prebolus quantitative MR heart perfusion imaging","volume":"52","author":"K\u00f6stler","year":"2004","journal-title":"Magn Reson Med"},{"issue":"1","key":"10.1186\/s12968-023-00945-w_bib10","doi-asserted-by":"crossref","first-page":"14","DOI":"10.1016\/j.jcmg.2013.08.014","article-title":"Diagnostic accuracy of stress perfusion CMR in comparison with quantitative coronary angiography: fully quantitative, semiquantitative, and qualitative assessment","volume":"7","author":"Mordini","year":"2014","journal-title":"JACC Cardiovasc Imaging"},{"key":"10.1186\/s12968-023-00945-w_bib11","doi-asserted-by":"crossref","first-page":"411","DOI":"10.1002\/jmri.23636","article-title":"Correction of arterial input function in dynamic contrast-enhanced MRI of the liver","volume":"36","author":"Wang","year":"2012","journal-title":"J Magn Reson Imaging"},{"key":"10.1186\/s12968-023-00945-w_bib12","first-page":"1300","article-title":"Correcting saturation effects of the arterial input function in dynamic susceptibility contrast-enhanced MRI: a Monte Carlo simulation","volume":"25","author":"Brunecker","year":"2007","journal-title":"Magn ResonImaging"},{"key":"10.1186\/s12968-023-00945-w_bib13","doi-asserted-by":"crossref","first-page":"539","DOI":"10.1161\/hc0402.102975","article-title":"Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart. A statement for healthcare professionals from the cardiac imaging committee of the council on clinical cardiology of the American Heart Association","volume":"105","author":"Cerqueira","year":"2002","journal-title":"Circulation"},{"key":"10.1186\/s12968-023-00945-w_bib14","first-page":"488","article-title":"A simplified method for quantification of myocardial blood flow using nitrogen-13-ammonia and dynamic PET","volume":"34","author":"Choi","year":"1993","journal-title":"J Nucl Med"},{"key":"10.1186\/s12968-023-00945-w_bib15","doi-asserted-by":"crossref","first-page":"171","DOI":"10.2967\/jnumed.111.095398","article-title":"Comparison of clinical tools for measurements of regional stress and rest myocardial blood flow assessed with 13N-ammonia PET\/CT","volume":"53","author":"Slomka","year":"2012","journal-title":"J Nucl Med"},{"key":"10.1186\/s12968-023-00945-w_bib16","doi-asserted-by":"crossref","first-page":"499","DOI":"10.1081\/JCMR-120030570","article-title":"Regional heterogeneity of myocardial perfusion in healthy human myocardium: assessment with magnetic resonance perfusion imaging","volume":"6","author":"Muehling","year":"2004","journal-title":"J Cardiovasc Magn Reson"},{"key":"10.1186\/s12968-023-00945-w_bib17","doi-asserted-by":"crossref","first-page":"1464","DOI":"10.1016\/j.jacc.2014.05.069","article-title":"Quantitative assessment of myocardial perfusion in the detection of significant coronary artery disease: cutoff values and diagnostic accuracy of quantitative [(15)O]H2O PET imaging","volume":"64","author":"Danad","year":"2014","journal-title":"J Am Coll Cardiol"},{"key":"10.1186\/s12968-023-00945-w_bib18","doi-asserted-by":"crossref","first-page":"24","DOI":"10.1007\/s12350-021-02731-6","article-title":"Quantitative myocardial perfusion response to adenosine and regadenoson in patients with suspected coronary artery disease","volume":"29","author":"Kero","year":"2022","journal-title":"J Nucl Cardiol"},{"key":"10.1186\/s12968-023-00945-w_bib19","doi-asserted-by":"crossref","first-page":"43","DOI":"10.1186\/s12968-017-0355-5","article-title":"Myocardial perfusion cardiovascular magnetic resonance: optimized dual sequence and reconstruction for quantification","volume":"19","author":"Kellman","year":"2017","journal-title":"J Cardiovasc Magn Reson"},{"key":"10.1186\/s12968-023-00945-w_bib20","doi-asserted-by":"crossref","first-page":"1477","DOI":"10.1002\/mrm.22101","article-title":"Model-based blind estimation of kinetic parameters in dynamic contrast enhanced (DCE)-MRI","volume":"62","author":"Fluckiger","year":"2009","journal-title":"Magn Reson Med"},{"key":"10.1186\/s12968-023-00945-w_bib21","doi-asserted-by":"crossref","first-page":"419","DOI":"10.1002\/mrm.22809","article-title":"Constrained estimation of the arterial input function for myocardial perfusion cardiovascular magnetic resonance","volume":"66","author":"Fluckiger","year":"2011","journal-title":"Magn Reson Med"},{"key":"10.1186\/s12968-023-00945-w_bib22","doi-asserted-by":"crossref","first-page":"12","DOI":"10.1093\/ehjdh\/ztac074","article-title":"AI-AIF: artificial intelligence-based arterial input function for quantitative stress perfusion cardiac magnetic resonance","volume":"4","author":"Scannell","year":"2022","journal-title":"Eur Heart J Digit Health"},{"key":"10.1186\/s12968-023-00945-w_bib23","doi-asserted-by":"crossref","first-page":"712","DOI":"10.1002\/mrm.27954","article-title":"Automatic in-line quantitative myocardial perfusion mapping: Processing algorithm and implementation","volume":"83","author":"Xue","year":"2020","journal-title":"Magn Reson Med"},{"key":"10.1186\/s12968-023-00945-w_bib24","doi-asserted-by":"crossref","first-page":"1252","DOI":"10.1007\/s12350-019-01810-z","article-title":"Evaluation of quantitative CMR perfusion imaging by comparison with simultaneous 15O-water-PET","volume":"28","author":"Kero","year":"2021","journal-title":"J Nucl Cardiol"},{"key":"10.1186\/s12968-023-00945-w_bib25","doi-asserted-by":"crossref","first-page":"694","DOI":"10.1177\/0284185118799538","article-title":"In vitro T2 relaxivities of the Gd-based contrast agents (GBCAs) in human blood at 1.5 and 3 T","volume":"60","author":"Shen","year":"2019","journal-title":"Acta Radiol"},{"key":"10.1186\/s12968-023-00945-w_bib26","doi-asserted-by":"crossref","first-page":"21","DOI":"10.1186\/s12968-015-0116-2","article-title":"Optimization of dual-saturation single bolus acquisition for quantitative cardiac perfusion and myocardial blood flow maps","volume":"17","author":"S\u00e1nchez-Gonz\u00e1lez","year":"2015","journal-title":"J Cardiovasc Magn Reson"},{"key":"10.1186\/s12968-023-00945-w_bib27","doi-asserted-by":"crossref","first-page":"1137","DOI":"10.1002\/mrm.28760","article-title":"A theoretical framework for retrospective T2* correction to the arterial input function in quantitative myocardial perfusion MRI","volume":"86","author":"Fan","year":"2021","journal-title":"Magn Reson Med"},{"key":"10.1186\/s12968-023-00945-w_bib28","doi-asserted-by":"crossref","first-page":"35","DOI":"10.1186\/s12968-021-00733-4","article-title":"Influence of the arterial input sampling location on the diagnostic accuracy of cardiovascular magnetic resonance stress myocardial perfusion quantification","volume":"23","author":"Milidonis","year":"2021","journal-title":"J Cardiovasc Magn Reson"},{"key":"10.1186\/s12968-023-00945-w_bib29","doi-asserted-by":"crossref","DOI":"10.1155\/2015\/843741","article-title":"A comparison of theory-based and experimentally determined myocardial signal intensity correction methods in first-pass perfusion magnetic resonance imaging","volume":"2015","author":"Fluckiger","year":"2015","journal-title":"Comput Math Methods Med"},{"key":"10.1186\/s12968-023-00945-w_bib30","doi-asserted-by":"crossref","first-page":"785","DOI":"10.1080\/10976640701545206","article-title":"Quantification of myocardial blood volume during dipyridamole and dobutamine stress: a perfusion MRI Study","volume":"9","author":"McCommis","year":"2007","journal-title":"J Cardiovasc Magn Reson"}],"container-title":["Journal of Cardiovascular Magnetic Resonance"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12968-023-00945-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12968-023-00945-w\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1097664723000352?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1097664723000352?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12968-023-00945-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,10,22]],"date-time":"2025-10-22T00:56:20Z","timestamp":1761094580000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1097664723000352"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,2]]},"references-count":30,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2023,2]]}},"alternative-id":["S1097664723000352"],"URL":"https:\/\/doi.org\/10.1186\/s12968-023-00945-w","relation":{},"ISSN":["1097-6647"],"issn-type":[{"value":"1097-6647","type":"print"}],"subject":[],"published":{"date-parts":[[2023,2]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"A simplified method to correct saturation of arterial input function for cardiac magnetic resonance first-pass perfusion imaging: validation with simultaneously acquired PET","name":"articletitle","label":"Article Title"},{"value":"Journal of Cardiovascular Magnetic Resonance","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1186\/s12968-023-00945-w","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2023 THE AUTHORS. Published by Elsevier Inc on behalf of the Society for Cardiovascular Magnetic Resonance","name":"copyright","label":"Copyright"}],"article-number":"35"}}