{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,1]],"date-time":"2026-06-01T15:32:11Z","timestamp":1780327931735,"version":"3.54.1"},"reference-count":35,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2020,10,6]],"date-time":"2020-10-06T00:00:00Z","timestamp":1601942400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2020,10,6]],"date-time":"2020-10-06T00:00:00Z","timestamp":1601942400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Reprod Health"],"published-print":{"date-parts":[[2020,12]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Less than 1% of married women in Tanzania use an Intrauterine Contraceptive Device (IUD) for contraception. An initiative by the International Federation of Gynecology and Obstetrics (FIGO) has been in progress since 2015 resulting in escalated method uptake in implementing hospitals. This study investigates failure rate, complications, and risk factors for one-year continuation of TCu380A IUD when used for immediate postpartum contraception under the initiative in Tanzania.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methodology<\/jats:title>\n                    <jats:p>A prospective cohort study of women who had TCu380A insertion within 48\u2009h of delivery in 6 hospitals in Tanzania between 1st December 2017 and 18th April 2018 was conducted. Face to face post insertion interviews were made with 1114 clients before discharge and later through phone calls up to the beginning of 13th month postpartum. Postpartum Intrauterine Device (PPIUD) continuation status, complications, duration of time they stayed with the IUD and the currently used method if PPIUD was discontinued were enquired. The outcome variable was PPIUD continuation at one year of IUD insertion. Data were analyzed using Statistical Product and Service Solutions software (SPSS) for Windows version 20 (IBM SPSS Statistics, Chicago, IL, USA).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>In total 511(45.8%)clients had consented and availed to complete the one-year follow-up. Out of these, 440 still had IUD, giving a one-year continuation rate of 86.1%. Most (63%) IUD discontinuations occurred in the period between 7th week and 6\u2009months of insertion. One-year method expulsion rate was 2.1%. There was one reported pregnancy that gives a method failure rate of about 2 per 1000. The independent risk factors in favor of method continuation at one year were absence of medical or social problem, being a youth (16\u201324\u2009years), and delivery by Cesarean section.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>The continuation rate when CuT380A is used for immediate postpartum contraception is high, with low complication and failure rates. Some medical and social factors are important for method continuation, hence the need to consider in training, counselling and advocacy.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s12978-020-00999-4","type":"journal-article","created":{"date-parts":[[2020,10,6]],"date-time":"2020-10-06T15:02:54Z","timestamp":1601996574000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":13,"title":["A one-year cohort study of complications, continuation, and failure rates of postpartum TCu380A in Tanzania"],"prefix":"10.1186","volume":"17","author":[{"given":"France John","family":"Rwegoshora","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Projestine Selestine","family":"Muganyizi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Grasiana Festus","family":"Kimario","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ponsian Patrick","family":"Paul","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anita","family":"Makins","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2020,10,6]]},"reference":[{"key":"999_CR1","doi-asserted-by":"publisher","first-page":"S11","DOI":"10.1186\/1742-4755-12-S2-S11","volume":"12 Suppl 2","author":"O Pasha","year":"2015","unstructured":"Pasha O, et al. Postpartum contraceptive use and unmet need for family planning in five low-income countries. Reprod Health. 2015;12 Suppl 2:S11.","journal-title":"Reprod Health"},{"issue":"5","key":"999_CR2","doi-asserted-by":"publisher","first-page":"356","DOI":"10.1080\/13625187.2016.1201655","volume":"21","author":"PD Blumenthal","year":"2016","unstructured":"Blumenthal PD, et al. Programmatic experience of post-partum IUD use in Zambia: an observational study on continuation and satisfaction. Eur J Contracept Reprod Health Care. 2016;21(5):356\u201360.","journal-title":"Eur J Contracept Reprod Health Care"},{"issue":"4","key":"999_CR3","doi-asserted-by":"publisher","first-page":"481","DOI":"10.1111\/jmwh.12984","volume":"64","author":"M Escobar","year":"2019","unstructured":"Escobar M, Shearin S. Immediate postpartum contraception: intrauterine device insertion. J Midwifery Womens Health. 2019;64(4):481\u20137.","journal-title":"J Midwifery Womens Health"},{"issue":"5","key":"999_CR4","doi-asserted-by":"publisher","first-page":"376","DOI":"10.1016\/j.contraception.2006.07.003","volume":"74","author":"K Eroglu","year":"2006","unstructured":"Eroglu K, et al. Comparison of efficacy and complications of IUD insertion in immediate postplacental\/early postpartum period with interval period: 1 year follow-up. Contraception. 2006;74(5):376\u201381.","journal-title":"Contraception"},{"key":"999_CR5","volume":"5","author":"DA Grimes","year":"2010","unstructured":"Grimes DA, et al. Immediate post-partum insertion of intrauterine devices. Cochrane Database Syst Rev. 2010;5:CD003036.","journal-title":"Cochrane Database Syst Rev"},{"key":"999_CR6","doi-asserted-by":"publisher","first-page":"7695847","DOI":"10.1155\/2016\/7695847","volume":"2016","author":"R Hooda","year":"2016","unstructured":"Hooda R, et al. Immediate postpartum intrauterine contraceptive device insertions in caesarean and vaginal deliveries: a comparative study of follow-up outcomes. Int J Reprod Med. 2016;2016:7695847.","journal-title":"Int J Reprod Med"},{"issue":"4","key":"999_CR7","doi-asserted-by":"publisher","first-page":"895","DOI":"10.1097\/AOG.0000000000002822","volume":"132","author":"TC Jatlaoui","year":"2018","unstructured":"Jatlaoui TC, et al. Intrauterine device expulsion after postpartum placement: a systematic review and meta-analysis. Obstet Gynecol. 2018;132(4):895\u2013905.","journal-title":"Obstet Gynecol"},{"issue":"1","key":"999_CR8","first-page":"5","volume":"43","author":"F Bonilla Rosales","year":"2005","unstructured":"Bonilla Rosales F, et al. Factors for expulsion of intrauterine device Tcu380A applied immediately postpartum and after a delayed period. Rev Med Inst Mex Seguro Soc. 2005;43(1):5\u201310.","journal-title":"Rev Med Inst Mex Seguro Soc"},{"issue":"5","key":"999_CR9","doi-asserted-by":"publisher","first-page":"337","DOI":"10.1007\/s13224-014-0550-3","volume":"64","author":"S Mishra","year":"2014","unstructured":"Mishra S. Evaluation of safety, efficacy, and expulsion of post-placental and intra-cesarean insertion of intrauterine contraceptive devices (PPIUCD). J Obstet Gynaecol India. 2014;64(5):337\u201343.","journal-title":"J Obstet Gynaecol India"},{"key":"999_CR10","doi-asserted-by":"publisher","first-page":"202","DOI":"10.1186\/s12884-015-0637-6","volume":"15","author":"A Sucak","year":"2015","unstructured":"Sucak A, et al. Immediate postplacental insertion of a copper intrauterine device: a pilot study to evaluate expulsion rate by mode of delivery. BMC Pregnancy Childbirth. 2015;15:202.","journal-title":"BMC Pregnancy Childbirth"},{"issue":"Suppl 2","key":"999_CR11","doi-asserted-by":"publisher","first-page":"S54","DOI":"10.1016\/j.ijgo.2015.03.008","volume":"130","author":"A Pfitzer","year":"2015","unstructured":"Pfitzer A, et al. A facility birth can be the time to start family planning: postpartum intrauterine device experiences from six countries. Int J Gynaecol Obstet. 2015;130(Suppl 2):S54\u201361.","journal-title":"Int J Gynaecol Obstet"},{"issue":"Suppl 1","key":"999_CR12","doi-asserted-by":"publisher","first-page":"20","DOI":"10.1002\/ijgo.12600","volume":"143","author":"A Makins","year":"2018","unstructured":"Makins A, et al. FIGO postpartum intrauterine device initiative: complication rates across six countries. Int J Gynaecol Obstet. 2018;143(Suppl 1):20\u20137.","journal-title":"Int J Gynaecol Obstet"},{"key":"999_CR13","unstructured":"National Bureau of Statistics (NBS) [Tanzania] and ICF Macro. Tanzania Demographic and Health Survey 2010. Dar es Salaam: NBS and ICF Macro; 2011."},{"issue":"1","key":"999_CR14","doi-asserted-by":"publisher","first-page":"362","DOI":"10.1186\/s12884-016-1160-0","volume":"16","author":"D Canning","year":"2016","unstructured":"Canning D, et al. Institutionalizing postpartum intrauterine device (IUD) services in Sri Lanka, Tanzania, and Nepal: study protocol for a cluster-randomized stepped-wedge trial. BMC Pregnancy Childbirth. 2016;16(1):362.","journal-title":"BMC Pregnancy Childbirth"},{"issue":"Suppl 1","key":"999_CR15","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1002\/ijgo.12597","volume":"143","author":"A Makins","year":"2018","unstructured":"Makins A, Arulkumaran S. Institutionalization of postpartum intrauterine devices. Int J Gynaecol Obstet. 2018;143(Suppl 1):1\u20133.","journal-title":"Int J Gynaecol Obstet"},{"issue":"6","key":"999_CR16","doi-asserted-by":"publisher","first-page":"800","DOI":"10.1097\/EDE.0b013e3181577654","volume":"18","author":"E von Elm","year":"2007","unstructured":"von Elm E, et al. The strengthening the reporting of observational studies in epidemiology (STROBE) statement: guidelines for reporting observational studies. Epidemiology. 2007;18(6):800\u20134.","journal-title":"Epidemiology"},{"key":"999_CR17","unstructured":"Ministry of Health, Community Development, Gender, Elderly and Children - MoHCDGEC\/Tanzania Mainland, Ministry of Health - MoH\/Zanzibar, National Bureau of Statistics - NBS\/Tanzania, Office of Chief Government Statistician - OCGS\/Zanzibar, and ICF. Tanzania Demographic and Health Survey and Malaria Indicator Survey (TDHS-MIS) 2015-16. Dar es Salaam\/Tanzania: MoHCDGEC, MoH, NBS, OCGS, and ICF; 2016."},{"key":"999_CR18","doi-asserted-by":"publisher","first-page":"211","DOI":"10.2147\/IJWH.S6914","volume":"2","author":"B Kaneshiro","year":"2010","unstructured":"Kaneshiro B, Aeby T. Long-term safety, efficacy, and patient acceptability of the intrauterine copper T-380A contraceptive device. Int J Women's Health. 2010;2:211\u201320.","journal-title":"Int J Women's Health"},{"issue":"6","key":"999_CR19","doi-asserted-by":"publisher","first-page":"631","DOI":"10.1016\/0010-7824(88)90046-7","volume":"38","author":"CB Champion","year":"1988","unstructured":"Champion CB, et al. A three-year evaluation of TCu 380 Ag and multiload cu 375 intrauterine devices. Contraception. 1988;38(6):631\u20139.","journal-title":"Contraception"},{"issue":"3","key":"999_CR20","doi-asserted-by":"publisher","first-page":"270","DOI":"10.1016\/j.contraception.2011.07.001","volume":"85","author":"SB Teal","year":"2012","unstructured":"Teal SB, Sheeder J. IUD use in adolescent mothers: retention, failure and reasons for discontinuation. Contraception. 2012;85(3):270\u20134.","journal-title":"Contraception"},{"key":"999_CR21","doi-asserted-by":"publisher","unstructured":"Muganyizi PS, Kimario G, Ponsian P, Howard K, Sethi M, Makins A. Clinical outcomes of postpartum intrauterine devices inserted by midwives in Tanzania. Int J Gynaecol Obstet. 2018;143(Suppl 1):38\u201342. https:\/\/doi.org\/10.1002\/ijgo.12603.","DOI":"10.1002\/ijgo.12603"},{"issue":"3","key":"999_CR22","doi-asserted-by":"publisher","first-page":"215","DOI":"10.1016\/j.contraception.2017.10.012","volume":"97","author":"AC Colwill","year":"2018","unstructured":"Colwill AC, et al. Six-week retention after postplacental copper intrauterine device placement. Contraception. 2018;97(3):215\u20138.","journal-title":"Contraception"},{"issue":"2","key":"999_CR23","doi-asserted-by":"publisher","first-page":"276","DOI":"10.9745\/GHSP-D-16-00072","volume":"4","author":"G Eluwa","year":"2016","unstructured":"Eluwa G, et al. Success providing postpartum intrauterine devices in private-sector health care facilities in Nigeria: factors associated with uptake. Glob Health Sci Pract. 2016;4(2):276\u201383.","journal-title":"Glob Health Sci Pract"},{"issue":"6","key":"999_CR24","doi-asserted-by":"publisher","first-page":"528","DOI":"10.1016\/j.contraception.2013.10.008","volume":"89","author":"TC Jatlaoui","year":"2014","unstructured":"Jatlaoui TC, et al. Postplacental intrauterine device insertion at a teaching hospital. Contraception. 2014;89(6):528\u201333.","journal-title":"Contraception"},{"issue":"3","key":"999_CR25","doi-asserted-by":"publisher","first-page":"202","DOI":"10.1007\/s13224-016-0940-9","volume":"67","author":"S Mishra","year":"2017","unstructured":"Mishra S. Tale of the tails, the missing postpartum IUCD strings. J Obstet Gynaecol India. 2017;67(3):202\u20137.","journal-title":"J Obstet Gynaecol India"},{"key":"999_CR26","volume":"1","author":"D Grimes","year":"2003","unstructured":"Grimes D, et al. Immediate post-partum insertion of intrauterine devices. Cochrane Database Syst Rev. 2003;1:CD003036.","journal-title":"Cochrane Database Syst Rev"},{"issue":"11","key":"999_CR27","doi-asserted-by":"publisher","first-page":"1301","DOI":"10.1111\/1471-0528.15842","volume":"126","author":"A Furey","year":"2019","unstructured":"Furey A, Fiander A. Postpartum contraception - the experience and findings from the leading safe choices programme in Tanzania and South Africa. BJOG. 2019;126(11):1301\u20134.","journal-title":"BJOG"},{"issue":"4","key":"999_CR28","doi-asserted-by":"publisher","first-page":"279","DOI":"10.1016\/j.contraception.2003.12.004","volume":"69","author":"S Celen","year":"2004","unstructured":"Celen S, et al. Clinical outcomes of early postplacental insertion of intrauterine contraceptive devices. Contraception. 2004;69(4):279\u201382.","journal-title":"Contraception"},{"key":"999_CR29","doi-asserted-by":"crossref","unstructured":"Cooper M, et al. Provision of immediate postpartum intrauterine contraception after vaginal birth within a public maternity setting: health services research evaluation. Acta Obstet Gynecol Scand. 2020;99:598\u2013607.","DOI":"10.1111\/aogs.13787"},{"issue":"4","key":"999_CR30","doi-asserted-by":"publisher","first-page":"212","DOI":"10.1016\/j.contraception.2018.12.003","volume":"99","author":"S Kumar","year":"2019","unstructured":"Kumar S, et al. One-year continuation of postpartum intrauterine contraceptive device: findings from a retrospective cohort study in India. Contraception. 2019;99(4):212\u20136.","journal-title":"Contraception"},{"issue":"6","key":"999_CR31","doi-asserted-by":"publisher","first-page":"532","DOI":"10.1016\/j.contraception.2015.09.007","volume":"92","author":"I Woo","year":"2015","unstructured":"Woo I, et al. Six-month and 1-year continuation rates following postpartum insertion of implants and intrauterine devices. Contraception. 2015;92(6):532\u20135.","journal-title":"Contraception"},{"key":"999_CR32","doi-asserted-by":"publisher","unstructured":"Goldthwaite LM, Sheeder J, Hyer J, Tocce K, Teal SB. Postplacental intrauterine device expulsion by 12 weeks: a prospective cohort study. Am J Obstet Gynecol. 2017;217(6):674.e1\u2013674.e8. https:\/\/doi.org\/10.1016\/j.ajog.2017.08.001.","DOI":"10.1016\/j.ajog.2017.08.001"},{"key":"999_CR33","unstructured":"Shukla M, Qureshi S, Chandrawati. Post-placental intrauterine device insertion--a five year experience at a tertiary care centre in north India. Indian J Med Res. 2012;136(3):432\u20135."},{"key":"999_CR34","doi-asserted-by":"publisher","first-page":"202","DOI":"10.1186\/s12884-015-0637-6","volume":"15","author":"A Sucak","year":"2015","unstructured":"Sucak A, OS, Celen S, Caglar T, Goksu G, Dasman N. Immediate postplacental insertion of copper intrauterine device: A pilot study to evaluate expulsion rate by mode of delivery. BMC Pregnancy Childbirth. 2015;15:202.","journal-title":"BMC Pregnancy Childbirth"},{"issue":"4","key":"999_CR35","doi-asserted-by":"publisher","first-page":"327","DOI":"10.1016\/j.contraception.2009.03.024","volume":"80","author":"N Kapp","year":"2009","unstructured":"Kapp N, Curtis KM. Intrauterine device insertion during the postpartum period: a systematic review. Contraception. 2009;80(4):327\u201336.","journal-title":"Contraception"}],"container-title":["Reproductive Health"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12978-020-00999-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12978-020-00999-4\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12978-020-00999-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,10,6]],"date-time":"2021-10-06T03:29:42Z","timestamp":1633490982000},"score":1,"resource":{"primary":{"URL":"https:\/\/reproductive-health-journal.biomedcentral.com\/articles\/10.1186\/s12978-020-00999-4"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,10,6]]},"references-count":35,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2020,12]]}},"alternative-id":["999"],"URL":"https:\/\/doi.org\/10.1186\/s12978-020-00999-4","relation":{"has-preprint":[{"id-type":"doi","id":"10.21203\/rs.3.rs-19521\/v3","asserted-by":"object"},{"id-type":"doi","id":"10.21203\/rs.3.rs-19521\/v2","asserted-by":"object"},{"id-type":"doi","id":"10.21203\/rs.3.rs-19521\/v1","asserted-by":"object"}]},"ISSN":["1742-4755"],"issn-type":[{"value":"1742-4755","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,10,6]]},"assertion":[{"value":"31 March 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"27 September 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"6 October 2020","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"This study obtained its Ethical clearance from the National Institute for Medical Research (NIMR) (Reference NIMR\/ HQ\/ R.8a\/Vol. IX\/2016) and Muhimbili University of Health and Allied Sciences (MUHAS). Permission to carry out the study was obtained from the Ministry of Health Community Development Gender Elderly and Children (MOHCDGEC), National Bureau of Statistics (NBS) and the relevant Health Management Teams in the study regions.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors have no conflict of interest to declare.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"150"}}