{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,26]],"date-time":"2026-10-26T18:02:18Z","timestamp":1793037738972,"version":"4.5.0"},"reference-count":47,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2018,6,26]],"date-time":"2018-06-26T00:00:00Z","timestamp":1529971200000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100001711","name":"Schweizerischer Nationalfonds zur F\u00f6rderung der Wissenschaftlichen Forschung","doi-asserted-by":"publisher","award":["51NF40 \u2013 16059"],"award-info":[{"award-number":["51NF40 \u2013 16059"]}],"id":[{"id":"10.13039\/501100001711","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100000009","name":"Foundation for the National Institutes of Health","doi-asserted-by":"publisher","award":["R01HD081525"],"award-info":[{"award-number":["R01HD081525"]}],"id":[{"id":"10.13039\/100000009","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J NeuroEngineering Rehabil"],"published-print":{"date-parts":[[2018,12]]},"DOI":"10.1186\/s12984-018-0396-5","type":"journal-article","created":{"date-parts":[[2018,6,26]],"date-time":"2018-06-26T00:05:37Z","timestamp":1529971537000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":59,"title":["Decoding the grasping intention from electromyography during reaching motions"],"prefix":"10.1186","volume":"15","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-1886-9367","authenticated-orcid":false,"given":"Iason","family":"Batzianoulis","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nili E.","family":"Krausz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ann M.","family":"Simon","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Levi","family":"Hargrove","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Aude","family":"Billard","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2018,6,26]]},"reference":[{"key":"396_CR1","doi-asserted-by":"crossref","unstructured":"Freeland AE, Psonak R. Traumatic below-elbow amputations. Orthopedics. 2007.","DOI":"10.3928\/01477447-20070201-16"},{"key":"396_CR2","doi-asserted-by":"crossref","unstructured":"Raichle KA, Hanley MA, Molton I, Kadel NJ, Campbell K, Phelps E, Ehde D, Smith DG. Prosthesis use in persons with lower- and upper-limb amputation. J Rehabil Res Dev. 2008.","DOI":"10.1682\/JRRD.2007.09.0151"},{"key":"396_CR3","unstructured":"Need-Directed Design of Prostheses and Enabling Resources in Amputation, Prosthesis Use, and Phantom Limb Pain: An Interdisciplinary Perspective. New York: Springer; 2010."},{"key":"396_CR4","doi-asserted-by":"crossref","unstructured":"Oltstlie k, Lesjo IM, Franklin RJ, Garfelt B, Skjeldal OH, Magnus P. Prosthesis rejection in acquired major upper-limb amputees: a population-based survey. Disabil Rehabil. 2012.","DOI":"10.2340\/16501977-0985"},{"key":"396_CR5","doi-asserted-by":"crossref","unstructured":"Cordella F, Ciancio AL, Sacchetti R, Davalli A, Cutti AG, Guglielmelli E, Zollo L. Literature review on needs of upper limb prosthesis users. Front Neurosci. 2016.","DOI":"10.3389\/fnins.2016.00209"},{"key":"396_CR6","doi-asserted-by":"crossref","unstructured":"Novak D, Riener R. A survey of sensor fusion methods in wearable robotics. Robot Auton Syst. 2014.","DOI":"10.1016\/j.robot.2014.08.012"},{"key":"396_CR7","doi-asserted-by":"crossref","unstructured":"Earley EJ, Hargrove LJ, Kuiken TA. Dual window pattern recognition classifier for improved partial-hand prosthesis control. Front Neurosci. 2016.","DOI":"10.3389\/fnins.2016.00058"},{"key":"396_CR8","doi-asserted-by":"crossref","unstructured":"Miller LA, Stubblefield KA, Lipschutz RD, Lock BA, Kuiken TA. Improved myoelectric prosthesis control using targeted reinnervation surgery: A case series. IEEE Trans Neural Syst Rehabil Eng. 2008.","DOI":"10.1109\/TNSRE.2007.911817"},{"key":"396_CR9","doi-asserted-by":"crossref","unstructured":"Kuiken TA, Li BA, Guanglin amd Lock, Lipschutz RD, Miller LA, A SK, Englehart K. Targeted muscle reinnervation for real-time myoelectric control of multifunction artificial arms. JAMA. 2009.","DOI":"10.1001\/jama.2009.116"},{"key":"396_CR10","doi-asserted-by":"crossref","unstructured":"Urbanchek MG, Wei B, Baghmanli Z, Sugg K, Cederna PS. Long-term stability of regenerative peripheral nerve interfaces. Plast Reocnstractive Surg. 2011.","DOI":"10.1097\/01.prs.0000406317.25436.00"},{"key":"396_CR11","doi-asserted-by":"crossref","unstructured":"Fougner AL, Stavdahl O, Kyberd PJ. System training and assessment in simultaneous proportional myoelectric prosthesis control. J Neuroengineering Rehabil. 2014.","DOI":"10.1186\/1743-0003-11-75"},{"key":"396_CR12","doi-asserted-by":"crossref","unstructured":"Young AJ, Smith LH, Rouse EJ, Hargrove LJ. Classification of simultaneous movements using surface emg pattern recognition. IEEE Trans Biomed Eng. 2013.","DOI":"10.1109\/TBME.2012.2232293"},{"key":"396_CR13","doi-asserted-by":"crossref","unstructured":"Smith LH, Kuiken TA, Hargrove LJ. Evaluation of linear regression simultaneous myoelectric control using intramuscular emg. IEEE Trans Biomed Eng. 2016.","DOI":"10.1109\/TBME.2015.2469741"},{"key":"396_CR14","doi-asserted-by":"crossref","unstructured":"Gonzalez-Vargas J, Dosen S, Amsuess S, Yu W, Farina D. Human-machine interface for the control of multi-function systems based on electrocutaneous menu: Application to multi-grasp prosthetic hands. PLoS ONE. 2015.","DOI":"10.1371\/journal.pone.0127528"},{"key":"396_CR15","doi-asserted-by":"crossref","unstructured":"Li G, Schultz AE, Kuiken TA. Quantifying pattern recognition-based myoelectric control of multifunctional transradial prostheses. IEEE Trans Neural Syst Rehabil Eng. 2010.","DOI":"10.1109\/TNSRE.2009.2039619"},{"key":"396_CR16","doi-asserted-by":"crossref","unstructured":"Naik GR, Al-Timemy AH, Nguyen HT. Transradial amputee gesture classification using an optimal number of semg sensors: An approach using ica clustering. IEEE Trans Neural Syst Rehabil Eng. 2016.","DOI":"10.1109\/TNSRE.2015.2478138"},{"key":"396_CR17","doi-asserted-by":"crossref","unstructured":"Khushaba RN, Kodagoda S, Takruri M, Dissanayake G. Toward improved control of prosthetic fingers using surface electromyogram (emg) signals. Expert Syst Appl. 2012.","DOI":"10.1016\/j.eswa.2012.02.192"},{"key":"396_CR18","doi-asserted-by":"crossref","unstructured":"Scheme E, Biron K, Englehart K. Improving myoelectric pattern recognition positional robustness using advanced training protocols. In: 33rd Annual International Conference of the IEEE EMBS. Boston: 2011.","DOI":"10.1109\/IEMBS.2011.6091196"},{"key":"396_CR19","doi-asserted-by":"crossref","unstructured":"Batzianoulis I, El-Khoury S, Pirondini E, Coscia M, Micera S, Billard A. Emg-based decoding of grasp gestures in reaching-to-grasping motions. Robot Auton Syst. 2017.","DOI":"10.1016\/j.robot.2016.12.014"},{"key":"396_CR20","doi-asserted-by":"crossref","unstructured":"Martelloni C, Carpaneto J, Micera S. Characterization of emg patterns from proximal arm muscles during object- and orientation-specific grasps. IEEE Trans Biomed Eng. 2009.","DOI":"10.1109\/TBME.2009.2026470"},{"key":"396_CR21","doi-asserted-by":"crossref","unstructured":"Rand MK, Shimansky YP, Stelmach ABMI, Stelmach HE. Quantitative model of transport- aperture coordination during reach-to-grasp movements. Exp Brain Res. 2008.","DOI":"10.1007\/s00221-008-1361-5"},{"key":"396_CR22","doi-asserted-by":"crossref","unstructured":"Wang J, Stelmach G. E. Coordination among the body segments during reach-to-grasp action involving the trunk. Exp Brain Res. 1998.","DOI":"10.1007\/s002210050578"},{"key":"396_CR23","doi-asserted-by":"crossref","unstructured":"Jeannerod M. The timing of natural prehension movements. J Motor Behav. 1984.","DOI":"10.1080\/00222895.1984.10735333"},{"key":"396_CR24","doi-asserted-by":"crossref","unstructured":"Haggard P, Wing A. Coordinated responses following mechanical perturbation of the arm during prehension. Exp Brain Res. 1995.","DOI":"10.1007\/BF00230652"},{"key":"396_CR25","doi-asserted-by":"crossref","unstructured":"Ghazaei G, Alameer A, Degenaar P, Morgan G, Nazarpour K. Deep learning-based artificial vision for grasp classification in myoelectric hands. J Neural Eng. 2017.","DOI":"10.1088\/1741-2552\/aa6802"},{"key":"396_CR26","doi-asserted-by":"crossref","unstructured":"Amsuess S, Vujaklija I, Goebel P, Roche AD, Graimann B, Aszmann OC, Dario F. Context-dependent upper limb prosthesis control for natural and robust use. IEEE Trans Neural Syst Rehabil Eng. 2016.","DOI":"10.1109\/TNSRE.2015.2454240"},{"key":"396_CR27","doi-asserted-by":"crossref","unstructured":"Farrell TR, Weir RF. The optimal controller delay for myoelectric prostheses. IEEE Trans Neural Syst Rehabil Eng. 2007.","DOI":"10.1109\/TNSRE.2007.891391"},{"key":"396_CR28","doi-asserted-by":"crossref","unstructured":"Santello M, Soechting JF. Gradual molding of the hand to object contours. J Neurophys. 1998.","DOI":"10.1152\/jn.1998.79.3.1307"},{"key":"396_CR29","doi-asserted-by":"crossref","unstructured":"Smith LH, L J Hargrove TAK B A Lock. Determining the optimal window length for pattern recognition-based myoelectric control: Balancing the competing effects of classification error and controller delay. IEEE Trans Neural Syst Rehabil Eng. 2011.","DOI":"10.1109\/TNSRE.2010.2100828"},{"key":"396_CR30","doi-asserted-by":"crossref","unstructured":"Englehart K, Hudgins B. A robust, real-time control scheme for multifunction myoelectric control. IEEE Trans Biomed Eng. 2003.","DOI":"10.1109\/TBME.2003.813539"},{"key":"396_CR31","doi-asserted-by":"crossref","unstructured":"Daley H, Englehart K, Hargrove L, Kuruganti U. High density electromyography data of normally limbed and transradial amputee subjects for multifunction prosthetic control. J Electromyogr Kinesiol. 2012.","DOI":"10.1016\/j.jelekin.2011.12.012"},{"key":"396_CR32","unstructured":"Jaeger H. The \u201cecho state\u201d approach to analyzing and training recurrent neural networks. Technical report, German National Research Institute for Computer Science. 2001."},{"key":"396_CR33","doi-asserted-by":"crossref","unstructured":"Li D, Han M, Wang J. Chaotic time series prediction based on a novel robust echo state network. IEEE Trans Neural Netw Learn Syst. 2012.","DOI":"10.1109\/TNNLS.2012.2188414"},{"key":"396_CR34","doi-asserted-by":"crossref","unstructured":"Xu M, Han M. Adaptive elastic echo state network for multivariate time series prediction. IEEE Trans Cybern; 46(10):2173\u20132183.","DOI":"10.1109\/TCYB.2015.2467167"},{"key":"396_CR35","doi-asserted-by":"crossref","unstructured":"Lenzi T, Lipsey J, Sensinger JW. The ric arm- a small anthropomorphic transhumeral prosthesis. IEEE Trans Mechatron. 2016.","DOI":"10.1109\/TMECH.2016.2596104"},{"key":"396_CR36","doi-asserted-by":"crossref","unstructured":"He J, Zhang D, Jiang N, Sheng X, Farina D, Zhu X. User adaptation in long-term, open-loop myoelectric training: implications for emg pattern recognition in prosthesis control. J Neural Eng. 2015.","DOI":"10.1088\/1741-2560\/12\/4\/046005"},{"key":"396_CR37","doi-asserted-by":"crossref","unstructured":"Peerdeman B, Boere D, Witteveen H, Veld RH, Hermens H, Stramigioli S, Rietman H, Veltink P, Misra S. Myoelectric forearm prostheses: State of the art from a user-centered perspective. J Rehabil Res Dev. 2011.","DOI":"10.1682\/JRRD.2010.08.0161"},{"key":"396_CR38","doi-asserted-by":"crossref","unstructured":"Y Geng YW O W Samuel, Li G. Improving the robustness of real-time myoelectric pattern recognition against arm position changes in transradial amputees. BioMed Res Int. 2017.","DOI":"10.1155\/2017\/5090454"},{"key":"396_CR39","doi-asserted-by":"crossref","unstructured":"J Liu XS, D Zhang, Zhu X. Quantification and solutions of arm movements effect on semg pattern recognition. Biomed Signal Process Control. 2014.","DOI":"10.1016\/j.bspc.2014.05.001"},{"key":"396_CR40","doi-asserted-by":"crossref","unstructured":"Yang D, Jiang L, Osborn L, Gu Y, Liu H. Dynamic training protocol improves the robustness of pr-based myoelectric control. Biomed Signal Process Control. 2017.","DOI":"10.1016\/j.bspc.2016.08.017"},{"key":"396_CR41","doi-asserted-by":"crossref","unstructured":"Wing AM, Turton A. Grasp size and accuracy of approach in reaching. J Mot Behav. 1986.","DOI":"10.1080\/00222895.1986.10735380"},{"key":"396_CR42","unstructured":"Jeannerod M, Paulignan PWY. Grasping an object: one movement, several components. In: Novartis Foundation Symposium. New Jersey: Wiley."},{"key":"396_CR43","doi-asserted-by":"crossref","unstructured":"T Supuk TBTKodek. Estimation of hand preshaping during human grasping. Med Eng Phys. 2005.","DOI":"10.1016\/S0021-9290(06)85070-0"},{"key":"396_CR44","doi-asserted-by":"crossref","unstructured":"Hargrove LJ, Turner K, Kuiken TA, Miller LA. Myoelectric pattern recognition outperforms direct control for transhumeral amputees with targeted muscle reinnervation: A randomized clinical trial. Sci Rep. 2017.","DOI":"10.1038\/s41598-017-14386-w"},{"key":"396_CR45","doi-asserted-by":"crossref","unstructured":"Gentilucci M, Benuzzi F, Bertolani L, Daprati E, Gangitano M. Language and motor control. Exp Brain Res. 2000.","DOI":"10.1007\/s002210000431"},{"key":"396_CR46","doi-asserted-by":"crossref","unstructured":"Bongersa RM, Zaala FT, Jeannerod M. Hand aperture patterns in prehension. Hum Mov Sci. 2012.","DOI":"10.1016\/j.humov.2011.07.014"},{"key":"396_CR47","doi-asserted-by":"crossref","unstructured":"Feix T, J Romero H-BS, Dollar AM, Kragic D. The grasp taxonomy of human grasp types. IEEE Trans Hum Mach Syst. 2015.","DOI":"10.1109\/THMS.2015.2470657"}],"container-title":["Journal of NeuroEngineering and Rehabilitation"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s12984-018-0396-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1186\/s12984-018-0396-5\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s12984-018-0396-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,8,26]],"date-time":"2022-08-26T10:08:00Z","timestamp":1661508480000},"score":1,"resource":{"primary":{"URL":"https:\/\/jneuroengrehab.biomedcentral.com\/articles\/10.1186\/s12984-018-0396-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,6,26]]},"references-count":47,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2018,12]]}},"alternative-id":["396"],"URL":"https:\/\/doi.org\/10.1186\/s12984-018-0396-5","relation":{},"ISSN":["1743-0003"],"issn-type":[{"value":"1743-0003","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,6,26]]},"assertion":[{"value":"26 December 2017","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"11 June 2018","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"26 June 2018","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare that they have no competing interests.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}},{"value":"Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Publisher\u2019s Note"}}],"article-number":"57"}}