{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,29]],"date-time":"2026-09-29T09:27:40Z","timestamp":1790674060704,"version":"4.1.0"},"reference-count":34,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2019,6,11]],"date-time":"2019-06-11T00:00:00Z","timestamp":1560211200000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2019,6,11]],"date-time":"2019-06-11T00:00:00Z","timestamp":1560211200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J NeuroEngineering Rehabil"],"published-print":{"date-parts":[[2019,12]]},"DOI":"10.1186\/s12984-019-0545-5","type":"journal-article","created":{"date-parts":[[2019,6,11]],"date-time":"2019-06-11T07:03:02Z","timestamp":1560236582000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":41,"title":["Comparison of vibrotactile and joint-torque feedback in a myoelectric upper-limb prosthesis"],"prefix":"10.1186","volume":"16","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-4699-9385","authenticated-orcid":false,"given":"Neha","family":"Thomas","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Garrett","family":"Ung","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Colette","family":"McGarvey","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jeremy D.","family":"Brown","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2019,6,11]]},"reference":[{"key":"545_CR1","doi-asserted-by":"publisher","first-page":"209","DOI":"10.3389\/fnins.2016.00209","volume":"10","author":"F Cordella","year":"2016","unstructured":"Cordella F, Ciancio AL, Sacchetti R, Davalli A, Cutti AG, Guglielmelli E, Zollo L. Literature Review on Needs of Upper Limb Prosthesis Users. Front Neurosci. 2016; 10:209. \n                    https:\/\/doi.org\/10.3389\/fnins.2016.00209\n                    \n                  .","journal-title":"Front Neurosci"},{"issue":"12","key":"545_CR2","doi-asserted-by":"publisher","first-page":"3785","DOI":"10.1007\/s00221-014-4071-1","volume":"232","author":"PS Lum","year":"2014","unstructured":"Lum PS, Black I, Holley RJ, Barth J, Dromerick AW. Internal models of upper limb prosthesis users when grasping and lifting a fragile object with their prosthetic limb. Exp Brain Res. 2014; 232(12):3785\u201395. \n                    https:\/\/doi.org\/10.1007\/s00221-014-4071-1\n                    \n                  .","journal-title":"Exp Brain Res"},{"issue":"3","key":"545_CR3","doi-asserted-by":"publisher","first-page":"236","DOI":"10.1080\/03093640600994581","volume":"31","author":"EA Biddiss","year":"2007","unstructured":"Biddiss EA, Chau TT. Upper limb prosthesis use and abandonment: A survey of the last 25 years. Prosthetics Orthot Int. 2007; 31(3):236\u201357. \n                    https:\/\/doi.org\/10.1080\/03093640600994581\n                    \n                  .","journal-title":"Prosthetics Orthot Int"},{"issue":"3","key":"545_CR4","doi-asserted-by":"publisher","first-page":"247","DOI":"10.1682\/JRRD.2014.08.0192","volume":"52","author":"Stephanie L. Carey","year":"2015","unstructured":"Carey SL, Lura DJ. Differences in myoelectric and body-powered upper-limb prostheses: Systematic literature review. Artic J Rehabil Res Dev. 2015. \n                    https:\/\/doi.org\/10.1682\/JRRD.2014.08.0192\n                    \n                  .","journal-title":"Journal of Rehabilitation Research and Development"},{"issue":"1","key":"545_CR5","first-page":"5","volume":"21","author":"J Doubler","year":"1984","unstructured":"Doubler J, Childress D. An Analysis of Extended Physiological Proprioception as a Prosthesis-Control Technique. J Rehabil Res Dev. 1984; 21(1):5\u201318.","journal-title":"J Rehabil Res Dev"},{"issue":"1","key":"545_CR6","first-page":"19","volume":"21","author":"Ja Doubler","year":"1984","unstructured":"Doubler Ja, Childress DS. Design and evaluation of a prosthesis control system based on the concept of extended physiological proprioception,. J Rehabil Res Dev. 1984; 21(1):19\u201331.","journal-title":"J Rehabil Res Dev"},{"issue":"3","key":"545_CR7","doi-asserted-by":"publisher","first-page":"215","DOI":"10.1109\/TNSRE.2016.2554061","volume":"25","author":"JD Brown","year":"2017","unstructured":"Brown JD, Kunz TS, Gardner D, Shelley MK, Davis AJ, Gillespie RB. An Empirical Evaluation of Force Feedback in Body-Powered Prostheses. IEEE Trans Neural Syst Rehabil Eng. 2017; 25(3):215\u201326. \n                    https:\/\/doi.org\/10.1109\/TNSRE.2016.2554061\n                    \n                  .","journal-title":"IEEE Trans Neural Syst Rehabil Eng"},{"issue":"3","key":"545_CR8","doi-asserted-by":"publisher","first-page":"204","DOI":"10.1177\/0309364614522260","volume":"39","author":"HJ Witteveen","year":"2015","unstructured":"Witteveen HJ, Rietman HS, Veltink PH. Vibrotactile grasping force and hand aperture feedback for myoelectric forearm prosthesis users. Prosthetics Orthot Int. 2015; 39(3):204\u201312. \n                    https:\/\/doi.org\/10.1177\/0309364614522260\n                    \n                  .","journal-title":"Prosthetics Orthot Int"},{"issue":"1","key":"545_CR9","doi-asserted-by":"publisher","first-page":"53","DOI":"10.1109\/TNSRE.2013.2267394","volume":"22","author":"HJB Witteveen","year":"2014","unstructured":"Witteveen HJB, Luft F, Rietman JS, Veltink PH. Stiffness Feedback for Myoelectric Forearm Prostheses Using Vibrotactile Stimulation. IEEE Trans Neural Syst Rehabil Eng. 2014; 22(1):53\u201361. \n                    https:\/\/doi.org\/10.1109\/TNSRE.2013.2267394\n                    \n                  .","journal-title":"IEEE Trans Neural Syst Rehabil Eng"},{"issue":"10","key":"545_CR10","doi-asserted-by":"publisher","first-page":"1308","DOI":"10.1177\/0269215518774104","volume":"32","author":"E Raveh","year":"2018","unstructured":"Raveh E, Friedman J, Portnoy S. Evaluation of the effects of adding vibrotactile feedback to myoelectric prosthesis users on performance and visual attention in a dual-task paradigm Article. Clin Rehabil. 2018; 32(10):1308\u201316. \n                    https:\/\/doi.org\/10.1177\/0269215518774104\n                    \n                  .","journal-title":"Clin Rehabil"},{"key":"545_CR11","doi-asserted-by":"publisher","first-page":"32","DOI":"10.1016\/j.humov.2018.01.008","volume":"58","author":"E Raveh","year":"2018","unstructured":"Raveh E, Portnoy S, Friedman J. Adding vibrotactile feedback to a myoelectric-controlled hand improves performance when online visual feedback is disturbed. Hum Mov Sci. 2018; 58:32\u201340. \n                    https:\/\/doi.org\/10.1016\/J.HUMOV.2018.01.008\n                    \n                  .","journal-title":"Hum Mov Sci"},{"issue":"12","key":"545_CR12","doi-asserted-by":"publisher","first-page":"1314","DOI":"10.1109\/TNSRE.2015.2500586","volume":"24","author":"Francesco Clemente","year":"2016","unstructured":"Clemente F, D\u2019Alonzo M, Controzzi M, Edin BB, Cipriani C. Non-Invasive, Temporally Discrete Feedback of Object Contact and Release Improves Grasp Control of Closed-Loop Myoelectric Transradial Prostheses. IEEE Trans Neural Syst Rehabil Eng. 2016. \n                    https:\/\/doi.org\/10.1109\/TNSRE.2015.2500586\n                    \n                  .","journal-title":"IEEE Transactions on Neural Systems and Rehabilitation Engineering"},{"key":"545_CR13","doi-asserted-by":"publisher","unstructured":"Bark K, Wheeler JW, Premakumar S, Cutkosky MR. Comparison of Skin Stretch and Vibrotactile Stimulation for Feedback of Proprioceptive Information. In: 2008 Symposium on Haptic Interfaces for Virtual Environment and Teleoperator Systems, Reno, NE. IEEE: 2008. p. 71\u20138. \n                    https:\/\/doi.org\/10.1109\/HAPTICS.2008.4479916\n                    \n                  .","DOI":"10.1109\/HAPTICS.2008.4479916"},{"issue":"8","key":"545_CR14","doi-asserted-by":"publisher","first-page":"827","DOI":"10.1109\/TNSRE.2015.2478153","volume":"24","author":"H Xu","year":"2016","unstructured":"Xu H, Zhang D, Huegel JC, Xu W, Zhu X. Effects of Different Tactile Feedback on Myoelectric Closed-Loop Control for Grasping Based on Electrotactile Stimulation. IEEE Trans Neural Syst Rehabil Eng. 2016; 24(8):827\u201336. \n                    https:\/\/doi.org\/10.1109\/TNSRE.2015.2478153\n                    \n                  .","journal-title":"IEEE Trans Neural Syst Rehabil Eng"},{"issue":"1","key":"545_CR15","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1682\/JRRD.1992.01.0001","volume":"29","author":"P Patterson","year":"1992","unstructured":"Patterson P, Katz J. Design and evaluation of a sensory feedback system that provides grasping pressure in a myoelectric hand. J Rehabil Res Dev. 1992; 29(1):1\u20138.","journal-title":"J Rehabil Res Dev"},{"key":"545_CR16","doi-asserted-by":"publisher","unstructured":"Brown JD, Paek A, Syed M, O\u2019Malley MK, Shewokis PA, Contreras-Vidal JL, Davis AJ, Gillespie RB. An exploration of grip force regulation with a low-impedance myoelectric prosthesis featuring referred haptic feedback. J NeuroEngineering Rehabil. 2015. \n                    https:\/\/doi.org\/10.1186\/s12984-015-0098-1\n                    \n                  .","DOI":"10.1186\/s12984-015-0098-1"},{"key":"545_CR17","doi-asserted-by":"publisher","unstructured":"Treadway E, Gillespie B, Bolger D, Blank A, O\u2019malley M, Davis A. The role of auxiliary and referred haptic feedback in myoelectric control. In: 2015 IEEE World Haptics Conference (WHC), Evanston, IL: 2015. p. 13\u201318. \n                    https:\/\/doi.org\/10.1109\/WHC.2015.7177684\n                    \n                  .","DOI":"10.1109\/WHC.2015.7177684"},{"key":"545_CR18","doi-asserted-by":"publisher","unstructured":"Markovic M, Schweisfurth MA, Engels LF, Bentz T, W\u00fcstefeld D, Farina D, Dosen S. The clinical relevance of advanced artificial feedback in the control of a multi-functional myoelectric prosthesis. J NeuroEngineering Rehabil. 2018; 15(1). \n                    https:\/\/doi.org\/10.1186\/s12984-018-0371-1\n                    \n                  .","DOI":"10.1186\/s12984-018-0371-1"},{"issue":"4","key":"545_CR19","doi-asserted-by":"publisher","first-page":"136","DOI":"10.1097\/JPO.0000000000000107","volume":"28","author":"T Rosenbaum-Chou","year":"2016","unstructured":"Rosenbaum-Chou T, Daly W, Austin R, Chaubey P, Boone DA. Development and Real World Use of a Vibratory Haptic Feedback System for Upper-Limb Prosthetic Users. J Prosthetics Orthot. 2016; 28(4):136\u201344. \n                    https:\/\/doi.org\/10.1097\/JPO.0000000000000107\n                    \n                  .","journal-title":"J Prosthetics Orthot"},{"key":"545_CR20","doi-asserted-by":"publisher","unstructured":"Battaglia E, Clark JP, Bianchi M, Catalano MG, Bicchi A, O\u2019Malley MK. The Rice Haptic Rocker: Skin stretch haptic feedback with the Pisa\/IIT SoftHand. In: 2017 IEEE World Haptics Conference (WHC), Munich: 2017. p. 7\u201312. \n                    https:\/\/doi.org\/10.1109\/WHC.2017.7989848\n                    \n                  .","DOI":"10.1109\/WHC.2017.7989848"},{"issue":"6","key":"545_CR21","doi-asserted-by":"publisher","first-page":"798","DOI":"10.1109\/TNSRE.2012.2206080","volume":"20","author":"K Kim","year":"2012","unstructured":"Kim K, Colgate JE. Haptic feedback enhances grip force control of sEMG-controlled prosthetic hands in targeted reinnervation amputees,. IEEE Trans Neural Syst Rehabil Eng: Publ IEEE Eng Med Biol Soc. 2012; 20(6):798\u2013805. \n                    https:\/\/doi.org\/10.1109\/TNSRE.2012.2206080\n                    \n                  .","journal-title":"IEEE Trans Neural Syst Rehabil Eng: Publ IEEE Eng Med Biol Soc"},{"issue":"1","key":"545_CR22","doi-asserted-by":"publisher","first-page":"1751","DOI":"10.1177\/1541931214581365","volume":"58","author":"Brandon J. Pitts","year":"2014","unstructured":"Pitts BJ, Sarter NB. Proceedings of the Human Factors and Ergonomics Society Annual Meeting. 2014; 58(1):1751\u20135. \n                    https:\/\/doi.org\/10.1177\/1541931214581365\n                    \n                  .","journal-title":"Proceedings of the Human Factors and Ergonomics Society Annual Meeting"},{"issue":"3","key":"545_CR23","doi-asserted-by":"publisher","first-page":"309","DOI":"10.1109\/TOH.2013.4","volume":"6","author":"S Feyzabadi","year":"2013","unstructured":"Feyzabadi S, Straube S, Folgheraiter M, Kirchner EA, Kim SK, Albiez JC. Human Force Discrimination during Active Arm Motion for Force Feedback Design. IEEE Trans Haptics. 2013; 6(3):309\u201319. \n                    https:\/\/doi.org\/10.1109\/TOH.2013.4\n                    \n                  .","journal-title":"IEEE Trans Haptics"},{"issue":"1","key":"545_CR24","doi-asserted-by":"publisher","first-page":"90","DOI":"10.1518\/001872008X250638","volume":"50","author":"Lynette A. Jones","year":"2008","unstructured":"Jones LA, Sarter NB. Tactile Displays: Guidance for Their Design and Application. Hum Factors: J Hum Factors Ergon Soc. 2008. \n                    https:\/\/doi.org\/10.1518\/001872008x250638\n                    \n                  .","journal-title":"Human Factors: The Journal of the Human Factors and Ergonomics Society"},{"key":"545_CR25","volume-title":"Discovering Statistics using R","author":"AP Field","year":"2012","unstructured":"Field AP, Miles J, Field Z. Discovering Statistics using R. Thousand Oaks: Sage; 2012, p. 957."},{"issue":"1","key":"545_CR26","doi-asserted-by":"publisher","first-page":"60","DOI":"10.1186\/1743-0003-8-60","volume":"8","author":"Ian Saunders","year":"2011","unstructured":"Saunders I, Vijayakumar S. The role of feed-forward and feedback processes for closed-loop prosthesis control. J Neuroengineering Rehabil. 2011; 8(60). \n                    https:\/\/doi.org\/10.1186\/1743-0003-8-60\n                    \n                  .","journal-title":"Journal of NeuroEngineering and Rehabilitation"},{"key":"545_CR27","doi-asserted-by":"publisher","DOI":"10.1109\/ICARM.2018.8610836","volume-title":"2018 3rd International Conference on Advanced Robotics and Mechatronics (ICARM)","author":"S Cheng","year":"2018","unstructured":"Cheng S, Yi A, Tan U, Zhang D. Closed-Loop System for Myoelectric Hand Control Based on Electrotactile Stimulation. In: 2018 3rd International Conference on Advanced Robotics and Mechatronics (ICARM). Singapore: IEEE: 2018. p. 486\u201390. \n                    https:\/\/doi.org\/10.1109\/ICARM.2018.8610836\n                    \n                  ."},{"key":"545_CR28","doi-asserted-by":"publisher","DOI":"10.1109\/ROMAN.2017.8172314","volume-title":"2017 26th IEEE International Symposium on Robot and Human Interactive Communication (RO-MAN)","author":"J Lee","year":"2017","unstructured":"Lee J, Choi MH, Jung JH, Hammond FL. Multimodal sensory feedback for virtual proprioception in powered upper-limb prostheses. In: 2017 26th IEEE International Symposium on Robot and Human Interactive Communication (RO-MAN). Lisbon: IEEE: 2017. p. 277\u201383. \n                    https:\/\/doi.org\/10.1109\/ROMAN.2017.8172314\n                    \n                  ."},{"issue":"3","key":"545_CR29","doi-asserted-by":"publisher","first-page":"387","DOI":"10.1109\/TOH.2016.2554120","volume":"9","author":"JD Brown","year":"2016","unstructured":"Brown JD, Shelley MK, Gardner D, Gansallo EA, Gillespie RB. Non-Colocated Kinesthetic Display Limits Compliance Discrimination in the Absence of Terminal Force Cues. IEEE Trans Haptics. 2016; 9(3):387\u201396. \n                    https:\/\/doi.org\/10.1109\/TOH.2016.2554120\n                    \n                  .","journal-title":"IEEE Trans Haptics"},{"issue":"5","key":"545_CR30","doi-asserted-by":"publisher","first-page":"260","DOI":"10.1016\/j.brainresbull.2010.11.011","volume":"85","author":"Antonio Frisoli","year":"2011","unstructured":"Frisoli A, Solazzi M, Reiner M, Bergamasco M. ARTICLE IN PRESS The contribution of cutaneous and kinesthetic sensory modalities in haptic perception of orientation. Brain Res Bull. 2010. \n                    https:\/\/doi.org\/10.1016\/j.brainresbull.2010.11.011\n                    \n                  .","journal-title":"Brain Research Bulletin"},{"issue":"3","key":"545_CR31","doi-asserted-by":"publisher","first-page":"2174","DOI":"10.1109\/LRA.2018.2810940","volume":"3","author":"Y Kamikawa","year":"2018","unstructured":"Kamikawa Y, Okamura AM. Comparison Between Force-Controlled Skin Deformation Feedback and Hand-Grounded Kinesthetic Force Feedback for Sensory Substitution. IEEE Robot Autom Lett. 2018; 3(3):2174\u201381. \n                    https:\/\/doi.org\/10.1109\/LRA.2018.2810940\n                    \n                  .","journal-title":"IEEE Robot Autom Lett"},{"issue":"1","key":"545_CR32","doi-asserted-by":"publisher","first-page":"72","DOI":"10.1186\/1743-0003-11-72","volume":"11","author":"MMD Sobuh","year":"2014","unstructured":"Sobuh MMD, Kenney LPJ, Galpin AJ, Thies SB, McLaughlin J, Kulkarni J, Kyberd P. Visuomotor behaviours when using a myoelectric prosthesis. J NeuroEngineering Rehabil. 2014; 11(1):72. \n                    https:\/\/doi.org\/10.1186\/1743-0003-11-72\n                    \n                  .","journal-title":"J NeuroEngineering Rehabil"},{"issue":"11","key":"545_CR33","doi-asserted-by":"publisher","first-page":"1311","DOI":"10.1068\/p2935","volume":"28","author":"M Land","year":"1999","unstructured":"Land M, Mennie N, Rusted J. The Roles of Vision and Eye Movements in the Control of Activities of Daily Living. Perception. 1999; 28(11):1311\u201328. \n                    https:\/\/doi.org\/10.1068\/p2935\n                    \n                  .","journal-title":"Perception"},{"key":"545_CR34","doi-asserted-by":"publisher","first-page":"40","DOI":"10.1186\/1743-0003-4-40","volume":"4","author":"A Chatterjee","year":"2007","unstructured":"Chatterjee A, Aggarwal V, Ramos A, Acharya S, Thakor NV. A brain-computer interface with vibrotactile biofeedback for haptic information,. J Neuroengineering Rehabil. 2007; 4:40. \n                    https:\/\/doi.org\/10.1186\/1743-0003-4-40\n                    \n                  .","journal-title":"J Neuroengineering Rehabil"}],"container-title":["Journal of NeuroEngineering and Rehabilitation"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s12984-019-0545-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1186\/s12984-019-0545-5\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s12984-019-0545-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,6,9]],"date-time":"2020-06-09T19:25:36Z","timestamp":1591730736000},"score":1,"resource":{"primary":{"URL":"https:\/\/jneuroengrehab.biomedcentral.com\/articles\/10.1186\/s12984-019-0545-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,6,11]]},"references-count":34,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2019,12]]}},"alternative-id":["545"],"URL":"https:\/\/doi.org\/10.1186\/s12984-019-0545-5","relation":{"has-preprint":[{"id-type":"doi","id":"10.1101\/623926","asserted-by":"object"}]},"ISSN":["1743-0003"],"issn-type":[{"value":"1743-0003","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,6,11]]},"assertion":[{"value":"15 January 2019","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"28 May 2019","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"11 June 2019","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"All participants were consented according to a protocol approved by the Johns Hopkins School of Medicine Institutional Review Board (Study# IRB00147458), and were compensated at a rate of $10 per hour.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"The individual featured in the images in this manuscript is the first author, who consents to this publication.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they have no competing interests.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"70"}}