{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,6]],"date-time":"2026-06-06T07:21:25Z","timestamp":1780730485329,"version":"3.54.1"},"reference-count":138,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2020,3,25]],"date-time":"2020-03-25T00:00:00Z","timestamp":1585094400000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2020,3,25]],"date-time":"2020-03-25T00:00:00Z","timestamp":1585094400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100010198","name":"Ministerio de Econom\u00eda, Industria y Competitividad, Gobierno de Espa\u00f1a","doi-asserted-by":"crossref","award":["RYC-2014-16613"],"award-info":[{"award-number":["RYC-2014-16613"]}],"id":[{"id":"10.13039\/501100010198","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J NeuroEngineering Rehabil"],"published-print":{"date-parts":[[2020,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:p>This paper reviews the technological advances and clinical results obtained in the neuroprosthetic management of foot drop. Functional electrical stimulation has been widely applied owing to its corrective abilities in patients suffering from a stroke, multiple sclerosis, or spinal cord injury among other pathologies. This review aims at identifying the progress made in this area over the last two decades, addressing two main questions: What is the status of neuroprosthetic technology in terms of architecture, sensorization, and control algorithms?. What is the current evidence on its functional and clinical efficacy? The results reveal the importance of systems capable of self-adjustment and the need for closed-loop control systems to adequately modulate assistance in individual conditions. Other advanced strategies, such as combining variable and constant frequency pulses, could also play an important role in reducing fatigue and obtaining better therapeutic results. The field not only would benefit from a deeper understanding of the kinematic, kinetic and neuromuscular implications and effects of more promising assistance strategies, but also there is a clear lack of long-term clinical studies addressing the therapeutic potential of these systems. This review paper provides an overview of current system design and control architectures choices with regard to their clinical effectiveness. Shortcomings and recommendations for future directions are identified.<\/jats:p>","DOI":"10.1186\/s12984-020-00668-4","type":"journal-article","created":{"date-parts":[[2020,3,25]],"date-time":"2020-03-25T08:02:53Z","timestamp":1585123373000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":72,"title":["Advances in neuroprosthetic management of foot drop: a review"],"prefix":"10.1186","volume":"17","author":[{"given":"Javier","family":"Gil-Castillo","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fady","family":"Alnajjar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Aikaterini","family":"Koutsou","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Diego","family":"Torricelli","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Juan C.","family":"Moreno","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2020,3,25]]},"reference":[{"issue":"8","key":"668_CR1","doi-asserted-by":"publisher","first-page":"646","DOI":"10.2340\/16501977-2136","volume":"48","author":"S Prenton","year":"2016","unstructured":"Prenton S, Hollands KL, Kenney LPJ. Functional electrical stimulation versus ankle foot orthoses for foot-drop: a meta-analysis of orthotic effects. J Rehabil Med. 2016;48(8):646\u201356.","journal-title":"J Rehabil Med"},{"issue":"4","key":"668_CR2","doi-asserted-by":"publisher","first-page":"260","DOI":"10.1109\/TNSRE.2002.806832","volume":"10","author":"GM Lyons","year":"2002","unstructured":"Lyons GM, Sinkj\u00e6r T, Burridge JH, Wilcox DJ. A review of portable FES-based neural orthoses for the correction of drop foot. IEEE Trans Neural Syst Rehabil Eng. 2002;10(4):260\u201379.","journal-title":"IEEE Trans Neural Syst Rehabil Eng"},{"issue":"5","key":"668_CR3","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1088\/1748-3190\/11\/5\/051002","volume":"11","author":"D Torricelli","year":"2016","unstructured":"Torricelli D, Gonzalez J, Weckx M, Jim\u00e9nez-Fabi\u00e1n R, Vanderborght B, Sartori M, Dosen S, Farina D, Lefeber D, Pons JL. Human-like compliant locomotion: state of the art of robotic implementations. Bioinspir Biomim. 2016;11(5):1\u201320.","journal-title":"Bioinspir Biomim"},{"key":"668_CR4","doi-asserted-by":"publisher","first-page":"101","DOI":"10.1016\/j.clinbiomech.2014.11.007","volume":"30","author":"PL Melo","year":"2015","unstructured":"Melo PL, Silva MT, Martins JM, Newman DJ. Technical developments of functional electrical stimulation to correct drop foot: sensing, actuation and control strategies. Clin Biomech. 2015;30:101\u201313.","journal-title":"Clin Biomech"},{"issue":"1","key":"668_CR5","doi-asserted-by":"publisher","first-page":"55","DOI":"10.2522\/ptj.20090140","volume":"90","author":"TM Kesar","year":"2010","unstructured":"Kesar TM, Perumal R, Jancosko A, Reisman DS, Rudolph KS, Higginson JS, Binder-Macleod SA. Novel patterns of functional electrical stimulation have an immediate effect on dorsiflexor muscle function during gait for people poststroke. Phys Ther. 2010;90(1):55\u201366.","journal-title":"Phys Ther"},{"issue":"2","key":"668_CR6","doi-asserted-by":"publisher","first-page":"390","DOI":"10.1016\/j.apmr.2013.10.017","volume":"95","author":"PR Bosch","year":"2014","unstructured":"Bosch PR, Harris JE, Wing K. Review of therapeutic electrical stimulation for dorsiflexion assist and orthotic substitution from the American congress of rehabilitation medicine stroke movement interventions subcommittee. Arch Phys Med Rehabil. 2014;95(2):390\u20136.","journal-title":"Arch Phys Med Rehabil"},{"issue":"6","key":"668_CR7","doi-asserted-by":"publisher","first-page":"577","DOI":"10.1111\/j.1525-1594.2004.07310.x","volume":"28","author":"AIR Kottink","year":"2004","unstructured":"Kottink AIR, Oostendorp LJM, Buurke JH, Nene AV, Hermens HJ, IJzerman MJ. The orthotic effect of functional electrical stimulation on the improvement of walking in stroke patients with a dropped foot: a systematic review. Artif Organs. 2004;28(6):577\u201386.","journal-title":"Artif Organs"},{"issue":"04","key":"668_CR8","doi-asserted-by":"publisher","first-page":"402","DOI":"10.1055\/s-0043-100760","volume":"155","author":"J Eike","year":"2017","unstructured":"Eike J, Daiwei Y, Henning W, Christina SC, Anna T, Kiriakos D. Treatment options for neurogenic drop foot: a systematic literature research. Zeitschrift f\u00fcr Orthop\u00e4die und Unfallchirurgie. 2017;155(04):402\u20138.","journal-title":"Zeitschrift f\u00fcr Orthop\u00e4die und Unfallchirurgie"},{"issue":"2","key":"668_CR9","first-page":"134","volume":"15","author":"L Dumitru","year":"2014","unstructured":"Dumitru L, Iliescu A, Dumitru C, Badea R, S\u0103vulescu S, Dinu H, Berteanu M. Physiological considerations on neuromuscular electrical stimulation (NMES) in muscular strength training. Palestrica of the third millennium \u2013 Civilization and Sport. 2014;15(2):134\u20139.","journal-title":"Palestrica of the third millennium \u2013 Civilization and Sport"},{"issue":"1","key":"668_CR10","first-page":"00","volume":"4","author":"JA Coy","year":"2001","unstructured":"Coy JA, L\u00f3pez JAB. Electroestimulaci\u00f3n funcional en el lesionado medular (revisi\u00f3n cient\u00edfica). Rev Iberoam Fisioter Kinesiol. 2001;4(1):00.","journal-title":"Rev Iberoam Fisioter Kinesiol"},{"key":"668_CR11","doi-asserted-by":"crossref","unstructured":"Park SJ, Wang JS. The immediate effect of FES and TENS on gait parameters in patients after stroke. Soc Phys Ther Sci. 2017;29(12):2212\u201314.","DOI":"10.1589\/jpts.29.2212"},{"key":"668_CR12","unstructured":"Liberson WT, Holmquest HJ, Scot D, Dow M. Functional electrotherapy: stimulation of the peroneal nerve synchronized with the swing phase of the gait of hemiplegic patients. Arch Phys Med Rehabil. 1961;42:101\u20135."},{"key":"668_CR13","doi-asserted-by":"crossref","unstructured":"O\u2019Keeffe DT, Lyons GM. A versatile drop foot stimulator for research applications. Med Eng Phys. 2002;24(3):237\u201342.","DOI":"10.1016\/S1350-4533(02)00011-5"},{"issue":"66","key":"668_CR14","first-page":"1","volume":"14","author":"J Malesevic","year":"2017","unstructured":"Malesevic J, Dujovic SD, Savi AM, Konstantinovic L, Vidakovic A, Bijelic G, Keller T. A decision support system for electrode shaping in multi-pad FES foot drop correction. J Neuro Eng Rehabil. 2017;14(66):1\u201314.","journal-title":"J Neuro Eng Rehabil"},{"key":"668_CR15","first-page":"40","volume":"2008","author":"CL Lynch","year":"2008","unstructured":"Lynch CL, Popovic MR. Closed-loop control of induced muscle contractions. IEEE Control Syst Mag. 2008;2008:40\u201350.","journal-title":"IEEE Control Syst Mag"},{"key":"668_CR16","first-page":"1","volume":"545408","author":"Z Tan","year":"2014","unstructured":"Tan Z, Liu H, Yan T, Jin D, He X, Zheng X, Xu S, Tan C. The effectiveness of functional electrical stimulation based on a normal gait pattern on subjects with early stroke: a randomized controlled trial. Biomed Res Int. 2014;545408:1\u20139.","journal-title":"Biomed Res Int"},{"key":"668_CR17","doi-asserted-by":"publisher","first-page":"1387","DOI":"10.1016\/S0021-9290(01)00105-1","volume":"34","author":"RR Neptune","year":"2001","unstructured":"Neptune RR, Kautz SA, Zajac FE. Contributions of the individual ankle plantar flexors to support, forward progression and swing initiation during walking. J Biomech. 2001;34:1387\u201398.","journal-title":"J Biomech"},{"key":"668_CR18","first-page":"1","volume-title":"Electroceuticals: advances in Electrostimulation therapies","author":"M van Der Linden","year":"2017","unstructured":"van Der Linden M, Mercer TH. Advances in Electrostimulation therapies: functional electrical stimulation to treat foot drop as a result of an upper motor neuron lesion. In: Majid A, editor. Electroceuticals: advances in Electrostimulation therapies. New York: Springer Publishing; 2017. p. 1\u201328."},{"issue":"4\u20135","key":"668_CR19","doi-asserted-by":"publisher","first-page":"361","DOI":"10.3233\/THC-2010-0588","volume":"8","author":"T Bajd","year":"2010","unstructured":"Bajd T, Munih M. Basic functional electrical stimulation (FES) of extremities: an engineer\u2019s view. Technol Health Care. 2010;8(4\u20135):361\u20139.","journal-title":"Technol Health Care"},{"issue":"3","key":"668_CR20","doi-asserted-by":"publisher","first-page":"187","DOI":"10.1017\/S1463423611000016","volume":"12","author":"J Shiels","year":"2011","unstructured":"Shiels J, Bulley C, Salisbury LG. A mixed methods service evaluation of a pilot functional electrical stimulation clinic for the correction of dropped foot in patients with chronic stroke. Prim Health Care Res Dev. 2011;12(3):187\u201399.","journal-title":"Prim Health Care Res Dev"},{"key":"668_CR21","doi-asserted-by":"publisher","first-page":"449","DOI":"10.3389\/fneur.2017.00449","volume":"8","author":"R Pilkar","year":"2017","unstructured":"Pilkar R, Ramanujam A, Nolan KJ. Alterations in spectral attributes of surface electromyograms after utilization of a foot drop stimulator during post-stroke gait. Front Neurol. 2017;8:449.","journal-title":"Front Neurol"},{"issue":"2","key":"668_CR22","doi-asserted-by":"publisher","first-page":"144","DOI":"10.1590\/2446-4740.07716","volume":"33","author":"DC de Souza","year":"2017","unstructured":"de Souza DC, do Gaiotto MC, Nogueira Neto GN, MCF C, Nohama P. Power amplifier circuits for functional electrical stimulation systems. Res Biomed Eng. 2017;33(2):144\u201355.","journal-title":"Res Biomed Eng"},{"key":"668_CR23","unstructured":"Basco CJA. Electroestimulaci\u00f3n funcional en el lesionado medular (revisi\u00f3n cient\u00edfica). 2001;4(1)."},{"issue":"6","key":"668_CR24","doi-asserted-by":"publisher","first-page":"967","DOI":"10.1113\/expphysiol.2006.033886","volume":"91","author":"T Kesar","year":"2006","unstructured":"Kesar T, Binder-macleod S. Effect of frequency and pulse duration on human muscle fatigue during repetitive electrical stimulation. Exp Physiol. 2006;91(6):967\u201376.","journal-title":"Exp Physiol"},{"issue":"4","key":"668_CR25","doi-asserted-by":"publisher","first-page":"662","DOI":"10.1016\/j.jelekin.2007.01.001","volume":"18","author":"T Kesar","year":"2008","unstructured":"Kesar T, Chou LW, Binder-Macleod SA. Effects of stimulation frequency versus pulse duration modulation on muscle fatigue. J Electromyogr Kinesiol. 2008;18(4):662\u201371.","journal-title":"J Electromyogr Kinesiol"},{"key":"668_CR26","doi-asserted-by":"publisher","first-page":"642","DOI":"10.1002\/mus.25951","volume":"57","author":"W Jeon","year":"2018","unstructured":"Jeon W, Griffin L. Effects of pulse duration on muscle fatigue during electrical stimulation inducing moderate-level contraction. Muscle Nerve. 2018;57:642\u20139.","journal-title":"Muscle Nerve"},{"issue":"12","key":"668_CR27","first-page":"3821","volume":"40","author":"TM Kesar","year":"2010","unstructured":"Kesar TM, Perumal R, Reisman DS, Rudolph KS, Higginson JS, Stuart A. Functional electrical stimulation of ankle plantar and dorsi-flexor muscles: effects on post-stroke gait. NIH Public Access. 2010;40(12):3821\u20137.","journal-title":"NIH Public Access"},{"key":"668_CR28","volume-title":"Peripheral nerve and muscle stimulation. Applied Neural Control Laboratory","author":"JT Mortimer","year":"2003","unstructured":"Mortimer JT, Bhadra N. Peripheral nerve and muscle stimulation. Applied Neural Control Laboratory. Cleveland: Case Western Reserve University; 2003."},{"issue":"6","key":"668_CR29","doi-asserted-by":"publisher","first-page":"964","DOI":"10.1109\/TNSRE.2014.2364735","volume":"23","author":"RJ Downey","year":"2015","unstructured":"Downey RJ, Bellman MJ, Kawai H, Gregory CM, Dixon WE. Comparing the induced muscle fatigue between asynchronous and synchronous electrical stimulation in able-bodied and spinal cord injured populations. IEEE Trans Neural Syst Rehabil Eng. 2015;23(6):964\u201372.","journal-title":"IEEE Trans Neural Syst Rehabil Eng"},{"issue":"1","key":"668_CR30","doi-asserted-by":"publisher","first-page":"59","DOI":"10.1109\/7333.918277","volume":"9","author":"MM Skelly","year":"2001","unstructured":"Skelly MM, Chizeck HJ. Real-time gait event detection for paraplegic FES walking. IEEE Trans Neural Syst Rehabil Eng. 2001;9(1):59\u201368.","journal-title":"IEEE Trans Neural Syst Rehabil Eng"},{"issue":"3","key":"668_CR31","doi-asserted-by":"publisher","first-page":"180","DOI":"10.1111\/j.1525-1403.2009.00213.x","volume":"12","author":"GP Braz","year":"2009","unstructured":"Braz GP, Russold M, Davis GM. Functional electrical stimulation control of standing and stepping after spinal cord injury: a review of technical characteristics. Neuromodulation. 2009;12(3):180\u201390.","journal-title":"Neuromodulation"},{"issue":"44","key":"668_CR32","first-page":"1319","volume":"2828","author":"L Meng","year":"2007","unstructured":"Meng L, Porr B, Gollee H. Technical developments of functional electrical stimulation to restore gait functions: sensing, control strategies and current commercial systems. Chin J Sci Instrum. 2007;2828(44):1319\u201334.","journal-title":"Chin J Sci Instrum"},{"key":"668_CR33","first-page":"4907","volume-title":"Gait phase detection in able-bodied subjects and dementia patients. 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)","author":"X Meng","year":"2013","unstructured":"Meng X, Yu H, Tham MP. Gait phase detection in able-bodied subjects and dementia patients. 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC); 2013. p. 4907\u201310."},{"issue":"1","key":"668_CR34","doi-asserted-by":"publisher","first-page":"60","DOI":"10.1186\/s12984-016-0169-y","volume":"13","author":"Z Li","year":"2016","unstructured":"Li Z, Guiraud D, Andreu D, Benoussaad M, Fattal C, Hayashibe M. Real-time estimation of FES-induced joint torque with evoked EMG: application to spinal cord injured patients. J NeuroEng Rehabil. 2016;13(1):60.","journal-title":"J NeuroEng Rehabil"},{"issue":"6","key":"668_CR35","doi-asserted-by":"publisher","first-page":"795","DOI":"10.1016\/j.jelekin.2014.09.008","volume":"24","author":"DB Popovi\u0107","year":"2014","unstructured":"Popovi\u0107 DB. Advances in functional electrical stimulation (FES). J Electromyogr Kinesiol. 2014;24(6):795\u2013802.","journal-title":"J Electromyogr Kinesiol"},{"issue":"4","key":"668_CR36","doi-asserted-by":"publisher","first-page":"315","DOI":"10.1177\/0954411917693879","volume":"231","author":"L Meng","year":"2017","unstructured":"Meng L, Porr B, Macleod CA, Gollee H. A functional electrical stimulation system for human walking inspired by reflexive control principles. Proc Inst Mech Eng H J Eng Med. 2017;231(4):315\u201325.","journal-title":"Proc Inst Mech Eng H J Eng Med"},{"key":"668_CR37","first-page":"11","volume-title":"Variable pass length ILC in FES-based drop foot rehabilitation. Conference paper: Workshop AUTOMED","author":"T Seel","year":"2012","unstructured":"Seel T, Schauer T, Raisch J. Variable pass length ILC in FES-based drop foot rehabilitation. Conference paper: Workshop AUTOMED, vol. 286; 2012. p. 11\u20132."},{"key":"668_CR38","doi-asserted-by":"publisher","first-page":"1","DOI":"10.3389\/fnins.2017.00347","volume":"11","author":"H Rouhani","year":"2017","unstructured":"Rouhani H, Same M, Masani K, Li YQ, Popovic MR. PID controller design for FES applied to ankle muscles in neuroprosthesis for standing balance. Front Neurosci. 2017;11:1\u201314.","journal-title":"Front Neurosci"},{"issue":"3","key":"668_CR39","doi-asserted-by":"publisher","first-page":"326","DOI":"10.1109\/7333.948462","volume":"9","author":"J Riess","year":"2001","unstructured":"Riess J, Abbas JJ. Adaptive control of cyclic movements as muscles fatigue using functional neuromuscular stimulation. IEEE Trans Neural Syst Rehabil Eng. 2001;9(3):326\u201330.","journal-title":"IEEE Trans Neural Syst Rehabil Eng"},{"issue":"3","key":"668_CR40","doi-asserted-by":"publisher","first-page":"300","DOI":"10.1109\/10.748983","volume":"46","author":"S Jonic","year":"2000","unstructured":"Jonic S, Jankovic T, Gajic V, Popovic D. Three machine learning techniques for automatic determination of rules to control locomotion. IEEE Trans Biomed Eng. 2000;46(3):300\u201310.","journal-title":"IEEE Trans Biomed Eng"},{"issue":"3","key":"668_CR41","doi-asserted-by":"publisher","first-page":"368","DOI":"10.1016\/j.conengprac.2008.08.003","volume":"17","author":"CT Freeman","year":"2009","unstructured":"Freeman CT, Hughes AM, Burridge JH, Chappell P, Lewin P, Rogers E. Iterative learning control of FES applied to the upper extremity for rehabilitation. Control Eng Pract. 2009;17(3):368\u201381.","journal-title":"Control Eng Pract"},{"issue":"5","key":"668_CR42","doi-asserted-by":"publisher","first-page":"E56","DOI":"10.1111\/aor.12400","volume":"39","author":"PL De Melo","year":"2015","unstructured":"De Melo PL, da Silva MT, Martins JM, Newman DJ. A microcontroller platform for the rapid prototyping of functional electrical stimulation-based gait neuroprostheses. Artif Organs. 2015;39(5):E56\u201366.","journal-title":"Artif Organs"},{"issue":"8","key":"668_CR43","doi-asserted-by":"publisher","first-page":"971","DOI":"10.1016\/j.apmr.2007.05.002","volume":"88","author":"AI Kottink","year":"2007","unstructured":"Kottink AI, Hermens HJ, Nene AV, Tenniglo MJ, van der Aa HE, Buschman HP, IJzerman MJ. A randomized controlled trial of an implantable 2-channel peroneal nerve stimulator on walking speed and activity in poststroke hemiplegia. Arch Phys Med Rehabil. 2007;88(8):971\u20138.","journal-title":"Arch Phys Med Rehabil"},{"issue":"4","key":"668_CR44","doi-asserted-by":"publisher","first-page":"437","DOI":"10.2522\/ptj.20070035","volume":"88","author":"AI Kottink","year":"2008","unstructured":"Kottink AI, Hermens HJ, Nene AV, Tenniglo MJ, Groothuis-Oudshoorn CG, IJzerman MJ. Therapeutic effect of an implantable peroneal nerve stimulator in subjects with chronic stroke and footdrop: a randomized controlled trial. Phys Ther. 2008;88(4):437\u201348.","journal-title":"Phys Ther"},{"key":"668_CR45","volume-title":"ShefStim. A clinical trial of self-tuning array stimulator for foot-drop SHEFSTIM: A clinical trial of self-tuning array stimulation for foot-drop. 1st Annual Conference of the International Functional Electrical Stimulation Society","author":"M Reeves","year":"2010","unstructured":"Reeves M, Bw H, Good T, Tj H, Van Der Meulen J, Clarke A, Pratt E, KPS N, Baker AT. ShefStim. A clinical trial of self-tuning array stimulator for foot-drop SHEFSTIM: A clinical trial of self-tuning array stimulation for foot-drop. 1st Annual Conference of the International Functional Electrical Stimulation Society; 2010."},{"issue":"1","key":"668_CR46","doi-asserted-by":"publisher","first-page":"74","DOI":"10.1016\/j.medengphy.2012.03.012","volume":"35","author":"BW Heller","year":"2013","unstructured":"Heller BW, Clarke AJ, Good TR, Healey TJ, Nair S, Pratt EJ, Reeves ML, van der Meulen JM, Barker AT. Automated setup of functional electrical stimulation for drop foot using a novel 64 channel prototype stimulator and electrode array: results from a gait-lab based study. Med Eng Phys. 2013;35(1):74\u201381.","journal-title":"Med Eng Phys"},{"issue":"10","key":"668_CR47","doi-asserted-by":"publisher","first-page":"1870","DOI":"10.1016\/j.apmr.2014.04.027","volume":"95","author":"S Prenton","year":"2014","unstructured":"Prenton S, Kenney LP, Stapleton C, Cooper G, Reeves ML, Heller BW, Sobuh M, Barker AT, Healey J, Good TR, Thies SB, Howard D, Williamson T. Feasibility study of a take-home array-based functional electrical stimulation system with automated setup for current functional electrical stimulation users with foot-drop. Arch Phys Med Rehabil. 2014;95(10):1870\u20137.","journal-title":"Arch Phys Med Rehabil"},{"issue":"20","key":"668_CR48","first-page":"309","volume":"28","author":"LP Kenney","year":"2015","unstructured":"Kenney LP, Heller BW, Barker AT, Reeves ML, Healey TJ, Good TR, Cooper G, Sha N, Prenton S, Howard D. The design development and evaluation of an array-based FES system with automated setup for the correction of drop foot. IFAC. 2015;28(20):309\u201314.","journal-title":"IFAC"},{"issue":"11","key":"668_CR49","doi-asserted-by":"publisher","first-page":"1159","DOI":"10.1016\/j.medengphy.2016.08.005","volume":"38","author":"LP Kenney","year":"2016","unstructured":"Kenney LP, Heller BW, Barker AT, Reeves ML, Healey J, Good TR, Cooper G, Sha N, Prenton S, Liu A, Howard D. A review of the design and clinical evaluation of the ShefStim array-based functional electrical stimulation system. Med Eng Phys. 2016;38(11):1159\u201365.","journal-title":"Med Eng Phys"},{"key":"668_CR50","volume-title":"Novel FES system to stimulate both dorsi\u2013 and plantar\u2013flexor muscles during stroke gait. 12th Annual Conference of the International FES Society","author":"R Perumal","year":"2007","unstructured":"Perumal R, Kesar TM, Wexler AS, Binder-Macleod SA. Novel FES system to stimulate both dorsi\u2013 and plantar\u2013flexor muscles during stroke gait. 12th Annual Conference of the International FES Society; 2007."},{"issue":"3","key":"668_CR51","doi-asserted-by":"publisher","first-page":"217","DOI":"10.3109\/03091900903580496","volume":"34","author":"SK Sabut","year":"2010","unstructured":"Sabut SK, Kumar R, Mahadevappa M. Design of a programmable multi-pattern FES system for restoring foot drop in stroke rehabilitation. J Med Eng Technol. 2010;34(3):217\u201323.","journal-title":"J Med Eng Technol"},{"key":"668_CR52","first-page":"196","volume-title":"A portable programmable transcutaneous neuroprosthesis with built-in self-test capability for training and mobility in paraplegic subjects. Conference paper: 11th Annual Conference of the International FES Society","author":"A Erfanian","year":"2006","unstructured":"Erfanian A, Hr K, Zohorian O, Emani F. A portable programmable transcutaneous neuroprosthesis with built-in self-test capability for training and mobility in paraplegic subjects. Conference paper: 11th Annual Conference of the International FES Society; 2006. p. 196\u20138."},{"issue":"1","key":"668_CR53","doi-asserted-by":"publisher","first-page":"41","DOI":"10.1682\/JRRD.2004.01.0041","volume":"41","author":"S Simcox","year":"2004","unstructured":"Simcox S, Davis G, Barriskill A, Middleton J, Bruinsma I, Duncan M, Smith R. A portable, 8-channel transcutaneous stimulator for paraplegic muscle training and mobility -- a technical note. J Rehabil Res Dev. 2004;41(1):41\u201351.","journal-title":"J Rehabil Res Dev"},{"issue":"2","key":"668_CR54","doi-asserted-by":"publisher","first-page":"152","DOI":"10.1177\/1545968309347681","volume":"24","author":"RB Stein","year":"2010","unstructured":"Stein RB, Everaert DG, Thompson AK, Chong SL, Whittaker M, Robertson J, Kuether G. Long-term therapeutic and orthotic effects of a foot drop stimulator on walking performance in progressive and nonprogressive neurological disorders. Neurorehabil Neural Repair. 2010;24(2):152\u201367.","journal-title":"Neurorehabil Neural Repair"},{"key":"668_CR55","doi-asserted-by":"publisher","first-page":"490","DOI":"10.1016\/j.promfg.2015.07.084","volume":"2","author":"S Ismail","year":"2015","unstructured":"Ismail S, Harun MN, Omar AH. Functional electrical stimulation for foot drop injury based on the arm swing motion. Procedia Manuf. 2015;2:490\u20134.","journal-title":"Procedia Manuf"},{"issue":"4","key":"668_CR56","doi-asserted-by":"publisher","first-page":"284","DOI":"10.1049\/htl.2016.0045","volume":"3","author":"T Watanabe","year":"2016","unstructured":"Watanabe T, Endo S, Morita R. Development of a prototype of portable FES rehabilitation system for relearning of gait for hemiplegic subjects. Healthcare Technol Lett. 2016;3(4):284\u20139.","journal-title":"Healthcare Technol Lett"},{"key":"668_CR57","doi-asserted-by":"crossref","unstructured":"Popovic MR, Keller T, Pappas IPI, M\u00fcller PY. Compex motion - new portable transcutaneous stimulator for neuroprosthetic applications. Porto: European Control Conference (ECC); 2001. pp. 3945\u201350.","DOI":"10.23919\/ECC.2001.7076551"},{"issue":"3","key":"668_CR58","doi-asserted-by":"publisher","first-page":"219","DOI":"10.1046\/j.1525-1594.2002.06934.x","volume":"26","author":"T Keller","year":"2002","unstructured":"Keller T, Popovic MR, Pappas IPI, Muller PY. Transcutaneous functional electrical stimulator \u201cCompex Motion.\u201d. Artif Organs. 2002;26(3):219\u201323.","journal-title":"Artif Organs"},{"issue":"1","key":"668_CR59","doi-asserted-by":"publisher","first-page":"81","DOI":"10.1016\/j.medengphy.2004.08.016","volume":"27","author":"MR Popovic","year":"2005","unstructured":"Popovic MR, Keller T. Modular transcutaneous functional electrical stimulation system. Med Eng Phys. 2005;27(1):81\u201392.","journal-title":"Med Eng Phys"},{"key":"668_CR60","volume-title":"New-generation fully programmable controller for functional electrical stimulation applications. A thesis submitted in conformity with the requirements for the degree of Master of Applied Science. University of Toronto","author":"D Agnello","year":"2011","unstructured":"Agnello D. New-generation fully programmable controller for functional electrical stimulation applications. A thesis submitted in conformity with the requirements for the degree of Master of Applied Science. University of Toronto; 2011."},{"issue":"5","key":"668_CR61","doi-asserted-by":"publisher","first-page":"687","DOI":"10.1016\/j.apmr.2009.12.024","volume":"91","author":"DG Embrey","year":"2010","unstructured":"Embrey DG, Holtz SL, Alon G, Brandsma BA, McCoy SW. Functional electrical stimulation to dorsiflexors and plantar flexors during gait to improve walking in adults with chronic hemiplegia. Arch Phys Med Rehabil. 2010;91(5):687\u201396.","journal-title":"Arch Phys Med Rehabil"},{"issue":"1","key":"668_CR62","doi-asserted-by":"publisher","first-page":"49","DOI":"10.1186\/1743-0003-8-49","volume":"8","author":"AH Do","year":"2011","unstructured":"Do AH, Wang PT, King CE, Abiri A, Nenadic Z. Brain computer interface controlled functional electrical stimulation system for ankle movement. J Neuro Eng Rehabil. 2011;8(1):49.","journal-title":"J Neuro Eng Rehabil"},{"key":"668_CR63","first-page":"5","volume-title":"Initial results with fully implanted Neurostep\u2122 FES system for foot drop. 10th Annual Conference of the International FES Society","author":"JA Hoffer","year":"2005","unstructured":"Hoffer JA, Baru M, Bedard S, Calderon E, Desmoulin G, Dhawan P, Jenne G, Whittaker M, Zwimpfer TJ. Initial results with fully implanted Neurostep\u2122 FES system for foot drop. 10th Annual Conference of the International FES Society; 2005. p. 5\u20137."},{"key":"668_CR64","volume-title":"Preliminary study to evaluate plantar flexor activation through Tibial nerve stimulation using the Neurostep \u00ae system","author":"WJ Atsma","year":"2012","unstructured":"Atsma WJ, B\u00e9rub\u00e9-Poliquin A, Fecteau P, Parmentier S, Prud\u2019homme M. Preliminary study to evaluate plantar flexor activation through Tibial nerve stimulation using the Neurostep \u00ae system; 2012."},{"issue":"2","key":"668_CR65","doi-asserted-by":"publisher","first-page":"195","DOI":"10.1016\/j.medengphy.2012.04.016","volume":"35","author":"M Chen","year":"2013","unstructured":"Chen M, Wu B, Lou X, Zhao T, Li J, Xu Z, Hu Z, Zheng X. A self-adaptive foot-drop corrector using functional electrical stimulation (FES) modulated by tibialis anterior electromyography (EMG) dataset. Med Eng Phys. 2013;35(2):195\u2013204.","journal-title":"Med Eng Phys"},{"key":"668_CR66","first-page":"6587","volume-title":"Iterative learning control of drop foot stimulation with array electrodes for selective muscle activation. IFAC Proceedings of the 19th World Congress","author":"M Valtin","year":"2014","unstructured":"Valtin M, Seel T, Raisch J, and Schauer T. Iterative learning control of drop foot stimulation with array electrodes for selective muscle activation. IFAC Proceedings of the 19th World Congress. 2014, 47, 3, 6587\u20136592."},{"key":"668_CR67","doi-asserted-by":"publisher","first-page":"355","DOI":"10.1016\/j.arcontrol.2017.09.014","volume":"44","author":"T Schauer","year":"2017","unstructured":"Schauer T. Sensing motion and muscle activity for feedback control of functional electrical stimulation: ten years of experience in Berlin. Annu Rev Control. 2017;44:355\u201374.","journal-title":"Annu Rev Control"},{"key":"668_CR68","first-page":"1482","volume-title":"Feedback control of foot eversion in the adaptive peroneal stimulator. 2014 22nd Mediterranean conference on control and automation, MED","author":"T Seel","year":"2014","unstructured":"Seel T, Laidig D, Valtin M, Werner C, Raisch J, Schauer T. Feedback control of foot eversion in the adaptive peroneal stimulator. 2014 22nd Mediterranean conference on control and automation, MED; 2014. p. 1482\u20137."},{"issue":"1","key":"668_CR69","doi-asserted-by":"crossref","first-page":"480","DOI":"10.1515\/cdbme-2015-0115","volume":"1","author":"T Seel","year":"2015","unstructured":"Seel T, Ruppel M, Valtin M, Schauer T. Multichannel FES parametrization for controlling foot motion in paretic gait. Curr Dir Biomed Eng. 2015;1(1):480\u20133.","journal-title":"Curr Dir Biomed Eng"},{"issue":"11","key":"668_CR70","doi-asserted-by":"publisher","first-page":"1205","DOI":"10.1016\/j.medengphy.2016.06.009","volume":"38","author":"T Seel","year":"2016","unstructured":"Seel T, Werner C, Schauer T. The adaptive drop foot stimulator \u2013 multivariable learning control of foot pitch and roll motion in paretic gait. Med Eng Phys. 2016;38(11):1205\u201313.","journal-title":"Med Eng Phys"},{"key":"668_CR71","unstructured":"Seel T, Landgraf L, Escobar VC, Schauer T. Online gait phase detection with automatic adaption to gait velocity changes using accelerometers and gyroscopes. Biomed Tech. 2014;59(s1):S795\u201398."},{"key":"668_CR72","doi-asserted-by":"publisher","first-page":"87","DOI":"10.1016\/j.conengprac.2015.11.007","volume":"48","author":"T Seel","year":"2016","unstructured":"Seel T, Werner C, Raisch J, Schauer T. Iterative learning control of a drop foot neuroprosthesis - generating physiological foot motion in paretic gait by automatic feedback control. Control Eng Pract. 2016;48:87\u201397.","journal-title":"Control Eng Pract"},{"issue":"3","key":"668_CR73","doi-asserted-by":"publisher","first-page":"400","DOI":"10.1016\/j.medengphy.2008.05.003","volume":"31","author":"PP Breen","year":"2009","unstructured":"Breen PP, Corley GJ, O\u2019Keeffe DT, Conway R, \u00d3Laighin G. A programmable and portable NMES device for drop foot correction and blood flow assist applications. Med Eng Phys. 2009;31(3):400\u20138.","journal-title":"Med Eng Phys"},{"issue":"2","key":"668_CR74","doi-asserted-by":"publisher","first-page":"177","DOI":"10.1016\/j.medengphy.2005.04.008","volume":"28","author":"PP Breen","year":"2006","unstructured":"Breen PP, O\u2019Keeffe DT, Conway R, Lyons GM. A system for the delivery of programmable, adaptive stimulation intensity envelopes for drop foot correction applications. Med Eng Phys. 2006;28(2):177\u201386.","journal-title":"Med Eng Phys"},{"key":"668_CR75","unstructured":"Li Z, Guiraud D, Andreu D, Fattal C, Hayashibe M. A hybrid functional electrical stimulation for real-time estimation of joint torque and closed-loop control of muscle activation. Eur J Transl Myol. 2013;26(3):193\u201396."},{"key":"668_CR76","volume-title":"Real-time EMG-feedback torque prediction and muscle activation control toward new modality in FES. A thesis from Universit\u00e9 Montpellier II, France","author":"Z Li","year":"2017","unstructured":"Li Z. Real-time EMG-feedback torque prediction and muscle activation control toward new modality in FES. A thesis from Universit\u00e9 Montpellier II, France; 2017."},{"key":"668_CR77","first-page":"623","volume-title":"Real-time closed-loop FES control of muscle activation with evoked EMG feedback for spinal cord injured patients. International IEEE\/EMBS Conference on Neural Engineering, NER","author":"Z Li","year":"2015","unstructured":"Li Z, Hayashibe M, Andreu D, Guiraud D. Real-time closed-loop FES control of muscle activation with evoked EMG feedback for spinal cord injured patients. International IEEE\/EMBS Conference on Neural Engineering, NER; 2015. p. 623\u20136."},{"issue":"6","key":"668_CR78","doi-asserted-by":"publisher","first-page":"1750063","DOI":"10.1142\/S0129065717500630","volume":"28","author":"Z Li","year":"2017","unstructured":"Li Z, Guiraud D, Andreu D, Gelis A, Fattal C, Hayashibe M. Real-time closed-loop functional electrical stimulation control of muscle activation with evoked electromyography feedback for spinal cord injured patients. Int J Neural Syst. 2017;28(6):1750063.","journal-title":"Int J Neural Syst"},{"issue":"263","key":"668_CR79","first-page":"203","volume":"26","author":"M Valtin","year":"2016","unstructured":"Valtin M, Kociemba K, Behling C, Kuberski B, Becker S, Schauer T. A versatile mobile stimulation system for transcutaneous FES RehaMovePro. Eur J Transl Myol. 2016;26(263):203\u20138.","journal-title":"Eur J Transl Myol"},{"issue":"8","key":"668_CR80","doi-asserted-by":"publisher","first-page":"649","DOI":"10.1111\/j.1525-1594.2008.00617.x","volume":"32","author":"H Nahrstaedt","year":"2008","unstructured":"Nahrstaedt H, Schauer T, Shalaby R, Hesse S, Raisch J. Automatic control of a drop-foot stimulator based on angle measurement using bioimpedance. Artif Organs. 2008;32(8):649\u201354.","journal-title":"Artif Organs"},{"issue":"8\u20139","key":"668_CR81","doi-asserted-by":"publisher","first-page":"784","DOI":"10.1139\/y04-078","volume":"82","author":"DJ Weber","year":"2004","unstructured":"Weber DJ, Stein RB, Chan KM, Loeb GE, Richmond FJ, Rolf R, James K, Chong SL, Thompson AK, Misiaszek J. Functional electrical stimulation using microstimulators to correct foot drop: a case study. Can J Physiol Pharmacol. 2004;82(8\u20139):784\u201392.","journal-title":"Can J Physiol Pharmacol"},{"key":"668_CR82","volume-title":"Information for Practitioners","author":"Otto Bock Healthcare Products GmbH","year":"2013","unstructured":"Otto Bock Healthcare Products GmbH (2013). Information for Practitioners. 646D622=EN-01-1205."},{"issue":"4","key":"668_CR83","doi-asserted-by":"publisher","first-page":"364","DOI":"10.2340\/16501977-1109","volume":"45","author":"SM Scott","year":"2013","unstructured":"Scott SM, van der Linden ML, Hooper JE, Cowan P, Mercer TH. Quantification of gait kinematics and walking ability of people with multiple sclerosis who are new users of functional electrical stimulation. J Rehabil Med. 2013;45(4):364\u20139.","journal-title":"J Rehabil Med"},{"issue":"1","key":"668_CR84","doi-asserted-by":"publisher","first-page":"58","DOI":"10.1111\/j.1525-1403.2009.00250.x","volume":"13","author":"C Barrett","year":"2010","unstructured":"Barrett C, Taylor P. The effects of the odstock drop foot stimulator on perceived quality of life for people with stroke and multiple sclerosis. Neuromodulation. 2010;13(1):58\u201364.","journal-title":"Neuromodulation"},{"issue":"5","key":"668_CR85","doi-asserted-by":"publisher","first-page":"438","DOI":"10.1016\/j.medengphy.2005.07.014","volume":"28","author":"DJ Hart","year":"2006","unstructured":"Hart DJ, Taylor PN, Chappell PH, Wood DE. A microcontroller system for investigating the catch effect: functional electrical stimulation of the common peroneal nerve. Med Eng Phys. 2006;28(5):438\u201348.","journal-title":"Med Eng Phys"},{"key":"668_CR86","doi-asserted-by":"publisher","first-page":"530906","DOI":"10.1100\/2012\/530906","volume":"2012","author":"S Springer","year":"2012","unstructured":"Springer S, Vatine JJ, Lipson R, Wolf A, Laufer Y. Effects of dual-channel functional electrical stimulation on gait performance in patients with hemiparesis. ScientificWorldJournal. 2012;2012:530906.","journal-title":"ScientificWorldJournal"},{"issue":"2","key":"668_CR87","doi-asserted-by":"publisher","first-page":"137","DOI":"10.1007\/s11832-015-0651-2","volume":"9","author":"S Khamis","year":"2015","unstructured":"Khamis S, Martikaro R, Wientroub S, Hemo Y, Hayek S. A functional electrical stimulation system improves knee control in crouch gait. J Child Orthop. 2015;9(2):137\u201343.","journal-title":"J Child Orthop"},{"issue":"2","key":"668_CR88","doi-asserted-by":"publisher","first-page":"117","DOI":"10.2340\/16501977-0489","volume":"42","author":"R Van Swigchem","year":"2010","unstructured":"Van Swigchem R, Vloothuis J, Den Boer J, Weerdesteyn V, Geurts ACH. Is transcutaneous peroneal stimulation beneficial to patients with chronic stroke using an ankle-foot orthosis? A within-subjects study of patients\u2019 satisfaction, walking speed and physical activity level. J Rehabil Med. 2010;42(2):117\u201321.","journal-title":"J Rehabil Med"},{"issue":"1","key":"668_CR89","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s13063-015-1128-9","volume":"17","author":"M Van Bloemendaal","year":"2016","unstructured":"Van Bloemendaal M, Bus SA, de Boer CE, Nollet F, Geurts ACH, Beelen A. Gait training assisted by multi-channel functional electrical stimulation early after stroke: study protocol for a randomized controlled trial. Trials. 2016;17(1):1\u20138.","journal-title":"Trials"},{"key":"668_CR90","doi-asserted-by":"publisher","first-page":"327","DOI":"10.1146\/annurev.bioeng.6.040803.140103","volume":"7","author":"PH Peckham","year":"2005","unstructured":"Peckham PH, Knutson JS. Functional electrical stimulation for neuromuscular applications. Annu Rev Biomed Eng. 2005;7:327\u201360.","journal-title":"Annu Rev Biomed Eng"},{"issue":"5","key":"668_CR91","doi-asserted-by":"publisher","first-page":"239","DOI":"10.7224\/1537-2073.2015-038","volume":"18","author":"PN Taylor","year":"2016","unstructured":"Taylor PN, Hart IAW, Khan MS, Slade-Sharman DEM. Correction of footdrop due to multiple sclerosis using the STIMuSTEP implanted dropped foot stimulator. Int J MS Care. 2016;18(5):239\u201347.","journal-title":"Int J MS Care"},{"issue":"4","key":"668_CR92","first-page":"547","volume":"36","author":"F Berenpas","year":"2018","unstructured":"Berenpas F, Schiemanck S, Beelen A, Nollet F, Weerdesteyn V, Geurts A. Kinematic and kinetic benefits of implantable peroneal nerve stimulation in people with post-stroke drop foot using an ankle-foot orthosis. Restor Neurol Neurosci. 2018;36(4):547\u201358.","journal-title":"Restor Neurol Neurosci"},{"issue":"2","key":"668_CR93","doi-asserted-by":"publisher","first-page":"251","DOI":"10.3233\/NRE-161410","volume":"40","author":"A Thibaut","year":"2017","unstructured":"Thibaut A, Moissenet F, Di Perri C, Schreiber C, Remacle A, Kolanowski E, Chntraine F, Bernard C, Hustinx R, Tshibanda JF, Filipetti P, Laureys S, Gosseries O. Brain plasticity after implanted peroneal nerve electrical stimulation to improve gait in chronic stroke patients. NeuroRehabilitation. 2017;40(2):251\u20138.","journal-title":"NeuroRehabilitation"},{"issue":"5","key":"668_CR94","doi-asserted-by":"publisher","first-page":"1685","DOI":"10.3171\/2014.12.JNS142110","volume":"126","author":"KD Martin","year":"2016","unstructured":"Martin KD, Polanski WH, Schulz AK, J\u00f6bges M, Hoff H, Schackert G, Pinzer T, Sobottka SB. Restoration of ankle movements with the ActiGait implantable drop foot stimulator: a safe and reliable treatment option for permanent central leg palsy. J Neurosurg. 2016;126(5):1685\u201390. Published online July 24, 2015. https:\/\/doi.org\/10.3171\/2014.12.JNS142110.","journal-title":"J Neurosurg"},{"key":"668_CR95","doi-asserted-by":"publisher","first-page":"1","DOI":"10.3171\/2016.4.JNS1660","volume":"124","author":"KD Martin","year":"2016","unstructured":"Martin KD, Polanski WH, Schulz AK, J\u00f6bges M, Ziemssen T, Schackert G, Pinzer T, Sobottka SB. ActiGait implantable drop foot stimulator in multiple sclerosis: A new indication. J Neurosurg. 2016;124:1\u20137. Published online July 1, 2016. https:\/\/doi.org\/10.3171\/2016.4.JNS1660.","journal-title":"J Neurosurg"},{"issue":"1","key":"668_CR96","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/1743-0003-12-1","volume":"12","author":"J Hausmann","year":"2015","unstructured":"Hausmann J, Sweeney-Reed CM, Sobieray U, Matzke M, Heinze HJ, Voges J, Buentjen L. Functional electrical stimulation through direct 4-channel nerve stimulation to improve gait in multiple sclerosis: a feasibility study. J Neuro Eng Rehabil. 2015;12(1):1\u20139.","journal-title":"J Neuro Eng Rehabil"},{"issue":"6","key":"668_CR97","first-page":"795","volume":"33","author":"S Schiemanck","year":"2015","unstructured":"Schiemanck S, Berenpas F, Van Swigchem R, van den Munckhof P, De Vries J, Beelen A, Nollet F, Geurts AC. Effects of implantable peroneal nerve stimulation on gait quality, energy expenditure, participation and user satisfaction in patients with post-stroke drop foot using an ankle-foot orthosis. Restor Neurol Neurosci. 2015;33(6):795\u2013807.","journal-title":"Restor Neurol Neurosci"},{"issue":"3","key":"668_CR98","doi-asserted-by":"publisher","first-page":"212","DOI":"10.2340\/16501977-0039","volume":"39","author":"J Burridge","year":"2007","unstructured":"Burridge J, Haugland M, Larsen B, Pickering RM, Svaneborg N, Iversen HK, Christensen PB, Haase J, Brennum J, Sinkjaer T. Phase II trial to evaluate the ActiGait implanted drop-foot stimulator in established hemiplegia. J Rehabil Med. 2007;39(3):212\u20138.","journal-title":"J Rehabil Med"},{"key":"668_CR99","volume-title":"A preliminary non-randomised study to evaluate the safety and performance of the ActiGait implanted drop-foot stimulator in established hemiplegia. 9th Annual Conference of the International FES Society","author":"M Haugland","year":"2004","unstructured":"Haugland M, Larsen B, Burridge J, Svaneborg N, Iversen H, Christensen PB, Sinkjaer T. A preliminary non-randomised study to evaluate the safety and performance of the ActiGait implanted drop-foot stimulator in established hemiplegia. 9th Annual Conference of the International FES Society; 2004."},{"issue":"6","key":"668_CR100","doi-asserted-by":"publisher","first-page":"2037","DOI":"10.1016\/j.wneu.2015.06.074","volume":"84","author":"KD Martin","year":"2015","unstructured":"Martin KD, Polanski W, Schackert G, Sobottka SB. New therapeutic option for drop foot with the actigait peroneal nerve stimulator - a technical note. World Neurosurg. 2015;84(6):2037\u201342.","journal-title":"World Neurosurg"},{"issue":"1","key":"668_CR101","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s12984-017-0275-5","volume":"14","author":"J Male\u0161evi\u0107","year":"2017","unstructured":"Male\u0161evi\u0107 J, Dujovi\u0107 SD, Savi\u0107 AM, Konstantinovi\u0107 L, Vidakovi\u0107 A, Bijeli\u0107 G, Male\u0161evi\u0107 N, Keller T. A decision support system for electrode shaping in multi-pad FES foot drop correction. J NeuroEng Rehabil. 2017;14(1):1\u201314.","journal-title":"J NeuroEng Rehabil"},{"key":"668_CR102","first-page":"13","volume-title":"Improvement of gait speed in patients with stroke related foot drop by combined FESIA WALK system with conventional therapy. Proceedings of 4th International Conference on Electrical, Electronics and Computing Engineering","author":"SD Dujovi\u0107","year":"2017","unstructured":"Dujovi\u0107 SD, Male\u0161evi\u0107 J, Popovi\u0107 M, Konstantinovi\u0107 L. Improvement of gait speed in patients with stroke related foot drop by combined FESIA WALK system with conventional therapy. Proceedings of 4th International Conference on Electrical, Electronics and Computing Engineering; 2017. p. 13\u20135."},{"key":"668_CR103","first-page":"59","volume-title":"An implantable foot drop stimulator. Proc. 5th Ann. IFESS Conf","author":"M Haugland","year":"2000","unstructured":"Haugland M, Childs C, Ladouceur M, Haase J, Sinkjaer T. An implantable foot drop stimulator. Proc. 5th Ann. IFESS Conf; 2000. p. 59."},{"issue":"7","key":"668_CR104","doi-asserted-by":"publisher","first-page":"755","DOI":"10.1016\/j.clinbiomech.2015.03.016","volume":"30","author":"KJ Nolan","year":"2015","unstructured":"Nolan KJ, Yarossi M, McLaughlin P. Changes in center of pressure displacement with the use of a foot drop stimulator in individuals with stroke. Clin Biomech. 2015;30(7):755\u201361.","journal-title":"Clin Biomech"},{"issue":"3","key":"668_CR105","doi-asserted-by":"publisher","first-page":"308","DOI":"10.1097\/PEP.0000000000000057","volume":"26","author":"D Pool","year":"2014","unstructured":"Pool D, Blackmore AM, Bear N, Valentine J. Effects of short-term daily community walk aide use on children with unilateral spastic cerebral palsy. Pediatr Phys Ther. 2014;26(3):308\u201317.","journal-title":"Pediatr Phys Ther"},{"issue":"5","key":"668_CR106","first-page":"36","volume":"66","author":"AM Elsodany","year":"2016","unstructured":"Elsodany AM, El-kafy EMA, El Fiky AR. Effectiveness of functional electrical stimulation for foot drop on walking abilities and balance performance in Saudi individuals with chronic stroke. Jokul. 2016;66(5):36\u201349.","journal-title":"Jokul"},{"issue":"223","key":"668_CR107","first-page":"6362","volume":"49","author":"K Jansen","year":"2016","unstructured":"Jansen K, Gote TB, Malt MA, Mandujano AM, Innvaer AR, Griffiths ST, Fevang J, Aarli \u00c5, Saetersdal C. Does walk aide\/bioness give a sustained effect on gait in children with spastic CP? Gait Posture. 2016;49(223):6362.","journal-title":"Gait Posture"},{"issue":"6","key":"668_CR108","doi-asserted-by":"publisher","first-page":"482","DOI":"10.3109\/17483107.2014.898340","volume":"10","author":"L Miller","year":"2015","unstructured":"Miller L, Rafferty D, Paul L, Mattison P. A comparison of the orthotic effect of the Odstock dropped foot stimulator and the Walkaide functional electrical stimulation systems on energy cost and speed of walking in multiple sclerosis. Disabil Rehabil Assist Technol. 2015;10(6):482\u20135.","journal-title":"Disabil Rehabil Assist Technol"},{"issue":"4","key":"668_CR109","doi-asserted-by":"publisher","first-page":"287","DOI":"10.3727\/194982413X13844488878899","volume":"15","author":"MK Carroll","year":"2014","unstructured":"Carroll MK, Toelle CA, Kim SH, Ambler SB, Highsmith MJ. The effect of the Walkaide functional electrical stimulation unit on gait asymmetry in a child with cerebral palsy: a case report. Technol Innov. 2014;15(4):287\u201392.","journal-title":"Technol Innov"},{"issue":"2","key":"668_CR110","doi-asserted-by":"publisher","first-page":"18","DOI":"10.17925\/ENR.2010.05.02.18","volume":"5","author":"MH Cameron","year":"2010","unstructured":"Cameron MH. The Walkaide functional electrical stimulation system - a novel therapeutic approach for foot drop in central nervous system disorders. Eur Neurol Rev. 2010;5(2):18\u201320.","journal-title":"Eur Neurol Rev"},{"issue":"3","key":"668_CR111","doi-asserted-by":"publisher","first-page":"146","DOI":"10.7224\/1537-2073.2013-032","volume":"16","author":"A Downing","year":"2014","unstructured":"Downing A, Ryn DV, Fecko A, Aiken C, McGowan S, Sawer S, McInerny T, Moore K, Passariello L, Rogers HL. Effect of a 2-week trial of functional electrical stimulation on gait function and quality of life in people with multiple sclerosis, international journal of MS care. Int J MS Care. 2014;16(3):146\u201352.","journal-title":"Int J MS Care"},{"issue":"11","key":"668_CR112","doi-asserted-by":"publisher","first-page":"1044","DOI":"10.1111\/j.1469-8749.2012.04401.x","volume":"54","author":"LA Prosser","year":"2012","unstructured":"Prosser LA, Curatalo LA, Alter KE, Damiano DL. Acceptability and potential effectiveness of a foot drop stimulator in children and adolescents with cerebral palsy. Dev Med Child Neurol. 2012;54(11):1044\u20139.","journal-title":"Dev Med Child Neurol"},{"key":"668_CR113","first-page":"108","volume-title":"Linearisation of electrically stimulated muscles by feedback control of the muscular recruitment measured by evoked EMG, in Proc. of the 17th International Conference on Methods and Models in Automation and Robotics, IEEE, Mi\u0229dzyzdroje, Poland","author":"C Klauer","year":"2012","unstructured":"Klauer C, Raisch J, Schauer T. Linearisation of electrically stimulated muscles by feedback control of the muscular recruitment measured by evoked EMG, in Proc. of the 17th International Conference on Methods and Models in Automation and Robotics, IEEE, Mi\u0229dzyzdroje, Poland; 2012. p. 108\u201313."},{"issue":"4","key":"668_CR114","doi-asserted-by":"publisher","first-page":"556","DOI":"10.1002\/mus.21736","volume":"42","author":"NM Malesevi\u0107","year":"2010","unstructured":"Malesevi\u0107 NM, Popovi\u0107 LZ, Schwirtlich L, Popovi\u0107 DB. Distributed low-frequency functional electrical stimulation delays muscle fatigue compared to conventional stimulation. Muscle Nerve. 2010;42(4):556\u201362.","journal-title":"Muscle Nerve"},{"issue":"1","key":"668_CR115","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1371\/journal.pone.0084740","volume":"9","author":"M Papaiordanidou","year":"2014","unstructured":"Papaiordanidou M, Billot M, Varray A, Martin A. Neuromuscular fatigue is not different between constant and variable frequency stimulation. PLoS One. 2014;9(1):1\u20138.","journal-title":"PLoS One"},{"issue":"4","key":"668_CR116","doi-asserted-by":"publisher","first-page":"662","DOI":"10.1016\/j.jelekin.2007.01.001","volume":"18","author":"T Kesar","year":"2008","unstructured":"Kesar T, Chou L-W, Binder-Macleod SA. Effects of stimulation frequency versus pulse duration modulation on muscle fatigue. J Electromyogr Kinesiol. 2008 August;18(4):662\u201371.","journal-title":"J Electromyogr Kinesiol"},{"key":"668_CR117","volume-title":"Electrode Position Revision. Leading Rehabilitation Through Technology. Odstock Medical Limited","author":"P Taylor","year":"2010","unstructured":"Taylor P. Electrode Position Revision. Leading Rehabilitation Through Technology. Odstock Medical Limited; 2010."},{"issue":"2","key":"668_CR118","doi-asserted-by":"publisher","first-page":"149","DOI":"10.1615\/CritRevBiomedEng.2013007621","volume":"41","author":"S Sabut","year":"2013","unstructured":"Sabut S, Bhattacharya SD, Mahadevappa M. Functional electrical stimulation on improving foot drop gait in poststroke rehabilitation: A review of its technology and clinical efficacy. Crit Rev Biomed Eng. 2013;41(2):149\u201360 2013.","journal-title":"Crit Rev Biomed Eng"},{"issue":"2","key":"668_CR119","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1371\/journal.pone.0149024","volume":"11","author":"MO Ibitoye","year":"2016","unstructured":"Ibitoye MO, Hamzaid NA, Hasnan N, Wahab AKA, Davis GM. Strategies for rapid muscle fatigue reduction during FES exercise in individuals with spinal cord injury: a systematic review. PLoS One. 2016;11(2):1\u201328.","journal-title":"PLoS One"},{"key":"668_CR120","first-page":"630","volume-title":"Iterative learning control with variable pass length applied to FES-based drop foot treatment (in German). 18th IFAC world Congres, Milano (Italy)","author":"T Seel","year":"2011","unstructured":"Seel T, Schauer T, and Raisch J. Iterative learning control with variable pass length applied to FES-based drop foot treatment (in German). 18th IFAC world Congres, Milano (Italy) 2011;61(9):630\u2013637."},{"key":"668_CR121","doi-asserted-by":"publisher","first-page":"98","DOI":"10.1016\/j.jbiomech.2017.08.006","volume":"63","author":"FO Barroso","year":"2017","unstructured":"Barroso FO, Torricelli D, Molina-Rueda F, Alguacil-Diego IM, Cano-de-la-Cuerda R, Santos C, Moreno JC, Miangolarra-Page JC, Pons JL. Combining muscle synergies and biomechanical analysis to assess gait in stroke patients. J Biomech. 2017;63:98\u2013103.","journal-title":"J Biomech"},{"issue":"4","key":"668_CR122","doi-asserted-by":"publisher","first-page":"667","DOI":"10.1016\/j.apmr.2014.11.017","volume":"96","author":"T Street","year":"2015","unstructured":"Street T, Taylor P, Swain I. Effectiveness of functional electrical stimulation on walking speed, functional walking category, and clinically meaningful changes for people with multiple sclerosis. Arch Phys Med Rehabil. 2015;96(4):667\u201372.","journal-title":"Arch Phys Med Rehabil"},{"issue":"2","key":"668_CR123","doi-asserted-by":"publisher","first-page":"154","DOI":"10.2340\/16501977-1090","volume":"45","author":"P Taylor","year":"2013","unstructured":"Taylor P, Humphreys L, Swain I. The long-term cost-effectiveness of the use of functional electrical stimulation for the correction of dropped foot due to upper motor neuron lesion. J Rehabil Med. 2013;45(2):154\u201360.","journal-title":"J Rehabil Med"},{"key":"668_CR124","volume-title":"Does functional electrical stimulation for foot drop strengthen Corticospinal connections? Neurorehabilitation and neural repair","author":"DG Everaert","year":"2009","unstructured":"Everaert DG, Thompson AK, Chong S, Stein RB. Does functional electrical stimulation for foot drop strengthen Corticospinal connections? Neurorehabilitation and neural repair; 2009."},{"issue":"2","key":"668_CR125","doi-asserted-by":"publisher","first-page":"451","DOI":"10.1007\/s10439-014-1148-8","volume":"43","author":"M Kafri","year":"2014","unstructured":"Kafri M, Laufer Y. Therapeutic effects of functional electrical stimulation on gait in individuals post-stroke. Ann Biomed Eng. 2014;43(2):451\u201366.","journal-title":"Ann Biomed Eng"},{"key":"668_CR126","doi-asserted-by":"publisher","first-page":"19","DOI":"10.2298\/JAC1301019A","volume":"21","author":"J Antonio","year":"2013","unstructured":"Antonio J, Koutsou AD, Bravo-esteban E, G\u00f3mez-soriano J, Gil-agudo \u00c1, Pons JL, Moreno JC. A comparison of customized strategies to manage muscle fatigue in isometric artificially elicited muscle contractions for incomplete SCI subjects. J Automatic Control. 2013;21:19\u201325.","journal-title":"J Automatic Control"},{"key":"668_CR127","doi-asserted-by":"crossref","unstructured":"Van Der Linden ML, Hooper JE, Cowan P, Weller BB, Mercer TH. Habitual functional electrical stimulation therapy improves gait kinematics and walking performance, but not patient-reported functional outcomes, of people with multiple sclerosis who present with foot-drop. PLoS ONE. 2014;9(8):e103368.","DOI":"10.1371\/journal.pone.0103368"},{"key":"668_CR128","doi-asserted-by":"publisher","first-page":"954","DOI":"10.1177\/1352458508090667","volume":"14","author":"L Paul","year":"2008","unstructured":"Paul L, Rafferty D, Young S, Miller L, Mattison P, Mcfadyen A. The effect of functional electrical stimulation on the physiological cost of gait in people with multiple sclerosis. Mult Scler. 2008;14:954\u201361.","journal-title":"Mult Scler"},{"issue":"4","key":"668_CR129","doi-asserted-by":"publisher","first-page":"493","DOI":"10.1177\/1352458508101320","volume":"15","author":"CL Barrett","year":"2009","unstructured":"Barrett CL, Mann GE, Taylor PN, Strike P. A randomized trial to investigate the effects of functional electrical stimulation and therapeutic exercise on walking performance for people with multiple sclerosis. Mult Scler. 2009;15(4):493\u2013504.","journal-title":"Mult Scler"},{"issue":"1","key":"668_CR130","doi-asserted-by":"publisher","first-page":"10","DOI":"10.17925\/USN.2015.11.01.10","volume":"11","author":"GP Dapul","year":"2015","unstructured":"Dapul GP, Bethoux F. Multiple sclerosis functional electrical stimulation for foot drop in multiple sclerosis. US Neurology. 2015;11(1):10\u20138.","journal-title":"US Neurology"},{"issue":"19","key":"668_CR131","doi-asserted-by":"publisher","first-page":"1594","DOI":"10.3109\/09638281003599596","volume":"32","author":"S Sabut","year":"2010","unstructured":"Sabut S, Mahadevappa M. Restoration of gait and motor recovery by functional electrical stimulation therapy in persons with stroke Restoration of gait and motor recovery by functional electrical stimulation therapy in persons with stroke. Disabil Rehabil. 2010;32(19):1594\u2013603.","journal-title":"Disabil Rehabil"},{"key":"668_CR132","unstructured":"Lindquist ARR, Prado CL, Barros RML, Mattioli R, da Costa PHL, Salvini TF. Gait training combining partial body-weight support, a treadmill, and functional electrical stimulation: Effects on poststroke gait. J Am Phys Ther Assoc. 2016;87(9):1144\u201354."},{"issue":"4","key":"668_CR133","doi-asserted-by":"publisher","first-page":"791","DOI":"10.3233\/NRE-172153","volume":"41","author":"SD Dujovi\u0107","year":"2017","unstructured":"Dujovi\u0107 SD, Male\u0161evi\u0107 J, Male\u0161evi\u0107 N, Vidakovi\u0107 AS, Bijeli\u0107 G, Keller T, Konstantinovi\u0107 L. Novel multi-pad functional electrical stimulation in stroke patients: a single-blind randomized study. NeuroRehabilitation. 2017;41(4):791\u2013800.","journal-title":"NeuroRehabilitation."},{"issue":"4","key":"668_CR134","doi-asserted-by":"publisher","first-page":"393","DOI":"10.3233\/NRE-2011-0717","volume":"29","author":"SK Sabut","year":"2011","unstructured":"Sabut SK, Sikdar C, Kumar R, Mahadevappa M. Functional electrical stimulation of dorsiflexor muscle: effects on dorsiflexor strength, plantarflexor spasticity, and motor recovery in stroke patients. NeuroRehabilitation. 2011;29(4):393\u2013400.","journal-title":"NeuroRehabilitation."},{"issue":"6","key":"668_CR135","doi-asserted-by":"publisher","first-page":"491","DOI":"10.1310\/tsr1906-491","volume":"19","author":"S Pereira","year":"2012","unstructured":"Pereira S, Mehta S, McIntyre A, Lobo L, Teasell RW. Functional electrical stimulation for improving gait in persons with chronic stroke. Top Stroke Rehabil. 2012;19(6):491\u20138.","journal-title":"Top Stroke Rehabil"},{"key":"668_CR136","first-page":"61","volume-title":"Restoration of gait and motor recovery by means of neuromuscular electrical stimulation in hemiplegics. 14th Annual Conference of the International FES Society","author":"SK Sabut","year":"2009","unstructured":"Sabut SK, Kumar R, Sikdar C, Manjunatha M. Restoration of gait and motor recovery by means of neuromuscular electrical stimulation in hemiplegics. 14th Annual Conference of the International FES Society; 2009. p. 61\u20133."},{"key":"668_CR137","first-page":"5839","volume-title":"Surface EMG analysis of tibialis anterior muscle in walking with FES in stroke subjects. Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC\u201910","author":"SK Sabut","year":"2010","unstructured":"Sabut SK, Kumar R, Lenka PK, Mahadevappa M. Surface EMG analysis of tibialis anterior muscle in walking with FES in stroke subjects. Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC\u201910; 2010. p. 5839\u201342."},{"issue":"12","key":"668_CR138","doi-asserted-by":"publisher","first-page":"1230","DOI":"10.1111\/dmcn.13501","volume":"59","author":"I Moll","year":"2017","unstructured":"Moll I, Vles JSH, Soudant DLHM, Witlox AMA, Staal HM, Speth LAWM, Vermeulen RJ. Functional electrical stimulation of the ankle dorsiflexors during walking in spastic cerebral palsy: a systematic review. Dev Med Child Neurol. 2017;59(12):1230\u20136.","journal-title":"Dev Med Child Neurol"}],"container-title":["Journal of NeuroEngineering and Rehabilitation"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s12984-020-00668-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1186\/s12984-020-00668-4\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s12984-020-00668-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,3,25]],"date-time":"2021-03-25T00:10:55Z","timestamp":1616631055000},"score":1,"resource":{"primary":{"URL":"https:\/\/jneuroengrehab.biomedcentral.com\/articles\/10.1186\/s12984-020-00668-4"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,3,25]]},"references-count":138,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2020,12]]}},"alternative-id":["668"],"URL":"https:\/\/doi.org\/10.1186\/s12984-020-00668-4","relation":{},"ISSN":["1743-0003"],"issn-type":[{"value":"1743-0003","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,3,25]]},"assertion":[{"value":"4 January 2019","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"27 February 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"25 March 2020","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Not applicable.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"46"}}