{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,23]],"date-time":"2026-10-23T21:14:54Z","timestamp":1792790094327,"version":"4.5.0"},"reference-count":58,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2020,4,9]],"date-time":"2020-04-09T00:00:00Z","timestamp":1586390400000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2020,4,9]],"date-time":"2020-04-09T00:00:00Z","timestamp":1586390400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J NeuroEngineering Rehabil"],"published-print":{"date-parts":[[2020,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>Tremor is the most common movement disorder with the highest prevalence in the upper limbs. The mechanical suppression of involuntary movements is an alternative and additional treatment to medication or surgery. Here we present a new, soft, lightweight, task asjustable and passive orthosis for tremor suppression.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>A new concept of a manual, textile-based, passive orthosis was designed with an integrated, task adjustable, air-filled structure, which can easily be inflated or deflated on-demand for a certain daily activity. The air-filled structure is placed on the dorsal side of the wrist and gets bent and compressed by movements when inflated. In a constant volume air-filled structure, air pressure increases while it is inflating, creating a counterforce to the compression caused by bending. We characterised the air-filled structure stiffness by measuring the reaction torque as a function of the angle of deflection on a test bench. Furthermore, we evaluated the efficacy of the developed passive soft orthosis by analysing the suppression of involuntary movements in the wrist of a tremor-affected patient during different activities of daily living (i.e. by calculating the power spectral densities of acceleration).<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>By putting special emphasis on the comfort and wearability of the orthosis, we achieved a lightweight design (33\u2009g). The measurements of the angular deflection and resulting reaction torques show non-linear, hysteretic, behaviour, as well as linear behaviour with a coefficient of determination (R<jats:sup>2<\/jats:sup>) between 0.95 and 0.99. Furthermore, we demonstrated that the soft orthosis significantly reduces tremor power for daily living activities, such as drinking from a cup, pouring water and drawing a spiral, by 74 to 82% (<jats:italic>p<\/jats:italic>\u2009=\u20090.03); confirmed by subjective tremor-reducing perception by the patient.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusion<\/jats:title>\n                <jats:p>The orthosis we developed is a lightweight and unobtrusive assistive technology, which suppresses involuntary movements and shows high wearability properties, with the potential to be comfortable. This air-structure technology could also be applied to other movement disorders, like spasticity, or even be integrated into future exoskeletons and exosuits for the implementation of variable stiffness in the systems.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s12984-020-00673-7","type":"journal-article","created":{"date-parts":[[2020,4,9]],"date-time":"2020-04-09T08:05:38Z","timestamp":1586419538000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":40,"title":["Design of a lightweight passive orthosis for tremor suppression"],"prefix":"10.1186","volume":"17","author":[{"given":"Nicolas Philip","family":"Fromme","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Martin","family":"Camenzind","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Robert","family":"Riener","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ren\u00e9 M.","family":"Rossi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2020,4,9]]},"reference":[{"issue":"S3","key":"673_CR1","doi-asserted-by":"publisher","first-page":"2","DOI":"10.1002\/mds.870131303","volume":"13","author":"G Deuschl","year":"1998","unstructured":"Deuschl G, Bain P, Brin M. Consensus statement of the Movement Disorder Society on tremor. Mov Disord. 1998;13(S3):2\u201323.","journal-title":"Mov Disord"},{"issue":"13","key":"673_CR2","doi-asserted-by":"publisher","first-page":"1793","DOI":"10.1002\/mds.25648","volume":"28","author":"R Elble","year":"2013","unstructured":"Elble R, Bain P, Jo\u00e3o Forjaz M, Haubenberger D, Testa C, Goetz CG, et al. Task force report: scales for screening and evaluating tremor: critique and recommendations. Mov Disord. 2013;28(13):1793\u2013800.","journal-title":"Mov Disord"},{"issue":"6","key":"673_CR3","doi-asserted-by":"publisher","first-page":"1096","DOI":"10.1002\/mds.23579","volume":"26","author":"R Elble","year":"2011","unstructured":"Elble R, Deuschl G. Milestones in tremor research. Mov Disord. 2011;26(6):1096\u2013105.","journal-title":"Mov Disord"},{"key":"673_CR4","unstructured":"Ellrichmann G. Vorkommen und Wertigkeit von Oberfrequenzen in der 24-Stunden-Elektromyographie und Accelerometrie. Doctoral dissertation: Ruhr University Bochum; 2007."},{"issue":"1","key":"673_CR5","doi-asserted-by":"publisher","first-page":"84","DOI":"10.1002\/1531-8257(200001)15:1<84::AID-MDS1014>3.0.CO;2-K","volume":"15","author":"J Raethjen","year":"2000","unstructured":"Raethjen J, Lindemann M, Schmajohann H, Wenzelburger R, Pfister G, Deuschl G. Multiple oscillators are causing parkinsonian and essential tremor. Mov Disord. 2000;15(1):84\u201394.","journal-title":"Mov Disord"},{"key":"673_CR6","doi-asserted-by":"publisher","first-page":"50","DOI":"10.1016\/j.jal.2015.02.003","volume":"16","author":"K Lopez-de-Ipi\u00f1a","year":"2014","unstructured":"Lopez-de-Ipi\u00f1a K, Bergareche A, de la Riva P, Faundez-Zanuy M, Calvo PM, Roure J, et al. Automatic non-linear analysis of non-invasive writing signals, applied to essential tremor. J Appl Log. 2014;16:50\u20139.","journal-title":"J Appl Log"},{"issue":"1","key":"673_CR7","doi-asserted-by":"publisher","first-page":"75","DOI":"10.1002\/mds.27121","volume":"33","author":"KP Bhatia","year":"2018","unstructured":"Bhatia KP, Bain P, Bajaj N, Elble RJ, Hallett M, Louis ED, et al. Consensus statement on the classification of tremors. From the task force on tremor of the International Parkinson and Movement Disorder Society. Mov Disord. 2018;33(1):75\u201387.","journal-title":"Mov Disord"},{"issue":"12","key":"673_CR8","doi-asserted-by":"publisher","first-page":"2143","DOI":"10.1212\/WNL.45.12.2143","volume":"45","author":"MC de Rijk","year":"1995","unstructured":"de Rijk MC, Breteler MM, Graveland GA, Ott A, Grobbee DE, van der Mech\u00e9 FG, et al. Prevalence of Parkinson\u2019s disease in the elderly: the Rotterdam study. Neurology. 1995;45(12):2143\u20136.","journal-title":"Neurology."},{"issue":"5","key":"673_CR9","doi-asserted-by":"publisher","first-page":"534","DOI":"10.1002\/mds.22838","volume":"25","author":"ED Louis","year":"2010","unstructured":"Louis ED, Ferreira JJ. How common is the most common adult movement disorder? Update on the worldwide prevalence of essential tremor. Mov Disord. 2010;25(5):534\u201341.","journal-title":"Mov Disord"},{"key":"673_CR10","doi-asserted-by":"crossref","first-page":"259","DOI":"10.5334\/tohm.198","volume":"4","author":"ED Louis","year":"2014","unstructured":"Louis ED, Ottman R. How many people in the USA have essential tremor? Deriving a population estimate based on epidemiological data. Tremor Other Hyperkinet Mov (N Y). 2014;4:259.","journal-title":"Tremor Other Hyperkinet Mov (N Y)"},{"key":"673_CR11","doi-asserted-by":"publisher","first-page":"S2999","DOI":"10.4137\/CMT.S2999","volume":"2","author":"G Grimaldi","year":"2010","unstructured":"Grimaldi G, Manto M. \u201cOld\u201d and emerging therapies of human tremor. Clin Med Insights Ther. 2010;2:CMT:S2999.","journal-title":"Clin Med Insights Ther"},{"issue":"5","key":"673_CR12","doi-asserted-by":"publisher","first-page":"666","DOI":"10.1002\/mds.21376","volume":"22","author":"KM Miller","year":"2007","unstructured":"Miller KM, Okun MS, Fernandez HF, Jacobson CE IV, Rodriguez RL, Bowers D. Depression symptoms in movement disorders: comparing Parkinson\u2019s disease, dystonia, and essential tremor. Mov Disord. 2007;22(5):666\u201372.","journal-title":"Mov Disord"},{"issue":"2","key":"673_CR13","doi-asserted-by":"publisher","first-page":"300","DOI":"10.1016\/j.jelekin.2013.12.007","volume":"24","author":"V Ruonala","year":"2014","unstructured":"Ruonala V, Meigal A, Rissanen SM, Airaksinen O, Kankaanp\u00e4\u00e4 M, Karjalainen PA. EMG signal morphology and kinematic parameters in essential tremor and Parkinson\u2019s disease patients. J Electromyogr Kinesiol. 2014;24(2):300\u20136.","journal-title":"J Electromyogr Kinesiol"},{"issue":"7","key":"673_CR14","doi-asserted-by":"publisher","first-page":"509","DOI":"10.1016\/j.parkreldis.2010.12.016","volume":"17","author":"RJ O\u2019Connor","year":"2011","unstructured":"O\u2019Connor RJ, Kini MU. Non-pharmacological and non-surgical interventions for tremor: a systematic review. Park Relat Disord. 2011;17(7):509\u201315.","journal-title":"Park Relat Disord."},{"issue":"9","key":"673_CR15","doi-asserted-by":"publisher","first-page":"604","DOI":"10.1016\/j.parkreldis.2010.07.011","volume":"16","author":"NL Diaz","year":"2010","unstructured":"Diaz NL, Louis ED. Survey of medication usage patterns among essential tremor patients: movement disorder specialists vs. general neurologists. Park Relat Disord. 2010;16(9):604\u20137.","journal-title":"Park Relat Disord"},{"issue":"1","key":"673_CR16","doi-asserted-by":"publisher","first-page":"107","DOI":"10.1002\/ana.25126","volume":"83","author":"JW Chang","year":"2018","unstructured":"Chang JW, Park CK, Lipsman N, Schwartz ML, Ghanouni P, Henderson JM, et al. A prospective trial of magnetic resonance\u2013guided focused ultrasound thalamotomy for essential tremor: results at the 2-year follow-up. Ann Neurol. 2018;83(1):107\u201314.","journal-title":"Ann Neurol"},{"issue":"4","key":"673_CR17","doi-asserted-by":"publisher","first-page":"1214","DOI":"10.3171\/2017.1.JNS162512","volume":"128","author":"SS Raju","year":"2018","unstructured":"Raju SS, Niranjan A, Monaco EA, Flickinger JC, Lunsford LD. Stereotactic radiosurgery for medically refractory multiple sclerosis\u2013related tremor. J Neurosurg. 2018;128(4):1214\u201321.","journal-title":"J Neurosurg"},{"issue":"1","key":"673_CR18","doi-asserted-by":"publisher","first-page":"54","DOI":"10.1159\/000486318","volume":"96","author":"F Velasco","year":"2018","unstructured":"Velasco F, Esqueda-Liquidano M, Velasco AL, Garc\u00eda-Gomar MG. Prelemniscal lesion for selective improvement of Parkinson disease tremor. Stereotact Funct Neurosurg. 2018;96(1):54\u20139.","journal-title":"Stereotact Funct Neurosurg"},{"issue":"1","key":"673_CR19","doi-asserted-by":"publisher","first-page":"93","DOI":"10.1186\/s12984-019-0543-7","volume":"16","author":"NP Fromme","year":"2019","unstructured":"Fromme NP, Camenzind M, Riener R, Rossi RM. Need for mechanically and ergonomically enhanced tremor-suppression orthoses for the upper limb: a systematic review. J Neuroeng Rehabil. 2019;16(1):93.","journal-title":"J Neuroeng Rehabil."},{"key":"673_CR20","first-page":"1","volume":"2","author":"E Rocon","year":"2012","unstructured":"Rocon E, Gallego J\u00c1, Belda-Lois JM, Benito-Le\u00f3n J, Luis PJ. Biomechanical loading as an alternative treatment for tremor: a review of two approaches. Tremor Other Hyperkinet Mov. 2012;2:1\u201313.","journal-title":"Tremor Other Hyperkinet Mov"},{"key":"673_CR21","doi-asserted-by":"crossref","unstructured":"Rocon E, Gallego JA, Belda-Lois JM, Pons JL. Assistive robotics as alternative treatment for tremor. In: Sanfeliu A, Ferre M, Armada MA, editors. Advances in Intelligent Systems and Computing, vol. 252: Springer Verlag; 2014. p. 173\u20139.","DOI":"10.1007\/978-3-319-03413-3_12"},{"key":"673_CR22","unstructured":"Takanokura M, Sugahara R, Miyake N, Ishiguro K, Muto T, Sakamoto K. Upper-limb orthoses implemented with air dashpots for suppression of pathological tremor in daily activites. In: ISB Conference July 2011. Brussel: Free University of Brussels; 2011. p. 3\u20134."},{"key":"673_CR23","unstructured":"Katz R, Buki E, Zacksenhouse M. Attenuating tremor using passive devices. In: Studies in Health Technology and Informatics, vol. 242: IOS Press; 2017. p. 741\u20137."},{"issue":"5","key":"673_CR24","doi-asserted-by":"publisher","first-page":"923","DOI":"10.1007\/s11517-017-1742-7","volume":"56","author":"E Buki","year":"2018","unstructured":"Buki E, Katz R, Zacksenhouse M, Schlesinger I. Vib-bracelet: a passive absorber for attenuating forearm tremor. Med Biol Eng Comput. 2018;56(5):923\u201330.","journal-title":"Med Biol Eng Comput"},{"issue":"1","key":"673_CR25","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s12984-018-0350-6","volume":"15","author":"CY Chu","year":"2018","unstructured":"Chu CY, Patterson RM. Soft robotic devices for hand rehabilitation and assistance: a narrative review. J Neuroeng Rehabil. 2018;15(1):1\u201314.","journal-title":"J Neuroeng Rehabil"},{"issue":"2","key":"673_CR26","doi-asserted-by":"publisher","first-page":"118","DOI":"10.1002\/mds.870050205","volume":"5","author":"RJ Elble","year":"1990","unstructured":"Elble RJ, Moody C, Higgins C. Primary writing tremor. A form of focal dystonia? Mov Disord. 1990;5(2):118\u201326.","journal-title":"Mov Disord"},{"issue":"1","key":"673_CR27","doi-asserted-by":"publisher","first-page":"29","DOI":"10.3727\/036012918X15202760634923","volume":"43","author":"A Kalaiarasi","year":"2018","unstructured":"Kalaiarasi A, Kumar LA. Sensor based portable tremor suppression device for stroke patients. Acupunct Electro Therapeutics Res. 2018;43(1):29\u201337.","journal-title":"Acupunct Electro Therapeutics Res"},{"key":"673_CR28","doi-asserted-by":"crossref","unstructured":"Rossi R. Comfort and thermoregulatory requirements in cold weather clothing. In: Textiles for Cold Weather Apparel: Woodhead Publishing Limited; 2009. p. 3\u201318.","DOI":"10.1533\/9781845697174.1.3"},{"key":"673_CR29","unstructured":"Hatch KL. Textile Science: West Pub; 1993."},{"key":"673_CR30","doi-asserted-by":"crossref","unstructured":"Motlogelwa S. Comfort and durability in high-performance clothing. High-Performance Appar. 2018:209\u201319.","DOI":"10.1016\/B978-0-08-100904-8.00012-2"},{"issue":"8","key":"673_CR31","doi-asserted-by":"publisher","first-page":"871","DOI":"10.1177\/0040517512452929","volume":"83","author":"G Fauland","year":"2013","unstructured":"Fauland G, Lenz A, Rohrer C, Bechtold T. Assessment of moisture management performance of multilayer compression bandages. Text Res J. 2013;83(8):871\u201380.","journal-title":"Text Res J"},{"issue":"2","key":"673_CR32","first-page":"86","volume":"52","author":"VT Bartels","year":"2001","unstructured":"Bartels VT, Umbach KH. Medizinische bandagen: physiologisches anforderungsprofil und optimierung des tragekomforts. ORTHOPADIE Tech. 2001;52(2):86\u201395.","journal-title":"ORTHOPADIE Tech"},{"key":"673_CR33","volume-title":"ISO 11092:2014 - Textilien \u2013 Physiologische Wirkungen \u2013 Messung des W\u00e4rme- und Wasserdampfdurchgangswiderstands unter station\u00e4ren Bedingungen (sweating guarded-hotplate test)","author":"International Organization for Standardization","year":"2014","unstructured":"International Organization for Standardization. ISO 11092:2014 - Textilien \u2013 Physiologische Wirkungen \u2013 Messung des W\u00e4rme- und Wasserdampfdurchgangswiderstands unter station\u00e4ren Bedingungen (sweating guarded-hotplate test). 2014."},{"issue":"6","key":"673_CR34","doi-asserted-by":"publisher","first-page":"423","DOI":"10.1111\/joss.12070","volume":"28","author":"E Kamalha","year":"2013","unstructured":"Kamalha E, Zeng Y, Mwasiagi JI, Kyatuheire S. The comfort dimension; a review of perception in clothing. J Sens Stud. 2013;28(6):423\u201344.","journal-title":"J Sens Stud"},{"key":"673_CR35","first-page":"1","volume-title":"Synthesis Lectures on Mobile and Pervasive Computing","author":"D Siewiorek","year":"2008","unstructured":"Siewiorek D, Smailagic A, Starner T. Application Design for Wearable Computing. In: Synthesis Lectures on Mobile and Pervasive Computing, vol. 3; 2008. p. 1\u201366."},{"issue":"4","key":"673_CR36","doi-asserted-by":"publisher","first-page":"141","DOI":"10.1007\/BF03399470","volume":"1","author":"RH Luchsinger","year":"2018","unstructured":"Luchsinger RH, Pedretti M, Reinhard A. Pressure induced stability: from pneumatic structures to Tensairity\u00ae. J Bionic Eng. 2018;1(4):141\u20138.","journal-title":"J Bionic Eng"},{"key":"673_CR37","first-page":"413","volume-title":"Comparative biomechanics","author":"S Vogel","year":"2003","unstructured":"Vogel S. Comparative biomechanics. Princeton: Princeton University Press; 2003. p. 413\u20135."},{"key":"673_CR38","first-page":"E91","volume":"61","author":"A Haag","year":"2018","unstructured":"Haag A, Weder M, Camenzind M, Rossi R. Laser transmission welding of membranes and textiles. Tech Textilien. 2018;61:E91\u20133.","journal-title":"Tech Textilien"},{"key":"673_CR39","doi-asserted-by":"crossref","unstructured":"Amberg M, Haag A, Storchenegger R, Rupper P, Lehmeier F, Rossi RM, et al. Absorbing TiO x thin film enabling laser welding of polyurethane membranes and polyamide fibers. Sci Technol Adv Mater. 2015;16(5).","DOI":"10.1088\/1468-6996\/16\/5\/055002"},{"key":"673_CR40","unstructured":"Geiger DW. Characterization of postural tremor in essential tremor using a seven-degree-of-freedom model. Master Thesis: Brigham Young University; 2014."},{"issue":"1","key":"673_CR41","doi-asserted-by":"publisher","first-page":"97","DOI":"10.1080\/00140138808966651","volume":"31","author":"C Wagner","year":"1988","unstructured":"Wagner C. The pianist\u2019s hand: anthropometry and biomechanics. Ergonomics. 1988;31(1):97\u2013131.","journal-title":"Ergonomics."},{"key":"673_CR42","doi-asserted-by":"crossref","unstructured":"Gates DH, Walters LS, Cowley J, Wilken JM. Range of Motion Requirements for Upper-Limb Activities of Daily Living. 2016;70(1).","DOI":"10.5014\/ajot.2016.015487"},{"issue":"7","key":"673_CR43","doi-asserted-by":"publisher","first-page":"537","DOI":"10.1016\/j.parkreldis.2011.04.017","volume":"17","author":"DA Heldman","year":"2011","unstructured":"Heldman DA, Jankovic J, Vaillancourt DE, Prodoehl J, Elble RJ, Giuffrida JP. Essential tremor quantification during activities of daily living. Park Relat Disord. 2011;17(7):537\u201342.","journal-title":"Park Relat Disord."},{"key":"673_CR44","doi-asserted-by":"crossref","unstructured":"Welch PD. The use of fast Fourier transform for the estimation of power spectra: A method based on time averaging over short, modified periodograms. 1967;AU-15(2):70\u20133.","DOI":"10.1109\/TAU.1967.1161901"},{"key":"673_CR45","doi-asserted-by":"publisher","first-page":"371","DOI":"10.1007\/978-1-4614-4027-7_20","volume-title":"Mechanisms and Emerging Therapies in Tremor Disorders","author":"J Mcnames","year":"2013","unstructured":"Mcnames J. Signal processing. In: Mechanisms and Emerging Therapies in Tremor Disorders; 2013. p. 371\u201389."},{"issue":"6","key":"673_CR46","doi-asserted-by":"publisher","first-page":"716","DOI":"10.1002\/mus.1063","volume":"24","author":"G Deuschl","year":"2001","unstructured":"Deuschl G, Raethjen J, Lindemann M, Krack P. The pathophysiology of tremor. Muscle Nerve. 2001;24(6):716\u201335.","journal-title":"Muscle Nerve"},{"issue":"1","key":"673_CR47","doi-asserted-by":"publisher","first-page":"54","DOI":"10.1007\/BF00870673","volume":"241","author":"PG Bain","year":"1993","unstructured":"Bain PG, Mally J, Gresty M, Findley LJ. Assessing the impact of essential tremor on upper limb function. J Neurol. 1993;241(1):54\u201361.","journal-title":"J Neurol"},{"issue":"4","key":"673_CR48","doi-asserted-by":"publisher","first-page":"488","DOI":"10.1016\/j.jbmt.2013.03.007","volume":"17","author":"N Riou","year":"2013","unstructured":"Riou N. Massage therapy for essential tremor: quieting the mind. J Bodyw Mov Ther. 2013;17(4):488\u201394.","journal-title":"J Bodyw Mov Ther"},{"issue":"4","key":"673_CR49","doi-asserted-by":"publisher","first-page":"1158","DOI":"10.1152\/jn.01014.2011","volume":"108","author":"D Formica","year":"2012","unstructured":"Formica D, Charles SK, Zollo L, Guglielmelli E, Hogan N, Krebs HI. The passive stiffness of the wrist and forearm. J Neurophysiol. 2012;108(4):1158\u201366.","journal-title":"J Neurophysiol"},{"issue":"6","key":"673_CR50","doi-asserted-by":"publisher","first-page":"1151","DOI":"10.1682\/JRRD.2014.11.0274","volume":"53","author":"DB Seegmiller","year":"2016","unstructured":"Seegmiller DB, Eggett DL, Charles SK. The effect of common wrist orthoses on the stiffness of wrist rotations. J Rehabil Res Dev. 2016;53(6):1151\u201366.","journal-title":"J Rehabil Res Dev"},{"issue":"1906","key":"673_CR51","first-page":"206","volume":"1906","author":"W Maurel","year":"1999","unstructured":"Maurel W. 3D modeling of the human upper limb including the biomechanics of joints, muscles and soft tissues. Biomechanics. 1999;1906(1906):206.","journal-title":"Biomechanics."},{"issue":"3","key":"673_CR52","doi-asserted-by":"publisher","first-page":"119","DOI":"10.1109\/86.331561","volume":"2","author":"DP Romilly","year":"1994","unstructured":"Romilly DP, Anglin C, Gosine RG, Hershler C, Raschke SU. A functional task analysis and motion simulation for the development of a powered upper-limb Orthosis. IEEE Trans Rehabil Eng. 1994;2(3):119\u201329.","journal-title":"IEEE Trans Rehabil Eng"},{"issue":"8","key":"673_CR53","doi-asserted-by":"publisher","first-page":"1661","DOI":"10.1016\/j.apmr.2005.02.008","volume":"86","author":"AG Mell","year":"2005","unstructured":"Mell AG, Childress BL, Hughes RE. The effect of wearing a wrist splint on shoulder kinematics during object manipulation. Arch Phys Med Rehabil. 2005;86(8):1661\u20134.","journal-title":"Arch Phys Med Rehabil"},{"issue":"1","key":"673_CR54","doi-asserted-by":"publisher","first-page":"108","DOI":"10.2486\/indhealth.48.108","volume":"48","author":"Y I-G","year":"2010","unstructured":"I-G Y, M-Y J, H-S J, Lee J. Effects of wrist-extension Orthosis on shoulder and scapular muscle activities during simulated assembly tasks. Ind Health. 2010;48(1):108\u201314.","journal-title":"Ind Health"},{"issue":"2","key":"673_CR55","doi-asserted-by":"publisher","first-page":"175","DOI":"10.1136\/ard.27.2.175","volume":"27","author":"CH Barnett","year":"1968","unstructured":"Barnett CH, Cobbold AF. Effects of age upon the mobility of human finger joints. Ann Rheum Dis. 1968;27(2):175\u20137.","journal-title":"Ann Rheum Dis"},{"issue":"2","key":"673_CR56","doi-asserted-by":"publisher","first-page":"151","DOI":"10.1136\/ard.62.2.151","volume":"62","author":"MM Haara","year":"2003","unstructured":"Haara MM, Manninen P, Kr\u00f6ger H, Arokoski JPA, K\u00e4rkk\u00e4inen A, Knekt P, et al. Osteoarthritis of finger joints in Finns aged 30 or over: prevalence, determinants, and association with mortality. Ann Rheum Dis. 2003;62(2):151\u20138.","journal-title":"Ann Rheum Dis"},{"issue":"03","key":"673_CR57","doi-asserted-by":"publisher","first-page":"235","DOI":"10.1055\/s-2001-17546","volume":"05","author":"RJ Miller","year":"2001","unstructured":"Miller RJ. Wrist MRI and Carpal Instability: What the Surgeon Needs to Know, and the Case for Dynamic Imaging. Semin Musculoskelet Radiol. 2001;05(03):235\u201340.","journal-title":"Semin Musculoskelet Radiol"},{"key":"673_CR58","doi-asserted-by":"crossref","unstructured":"Hasegawa Y, Hasegawa T, Eguchi K. Pneumatic tubular body fixture for wearable assistive device -Analysis and design of active cuff to hold upper limb. Int Conf Intell Robots Syst. IEEE. 2014:2140\u20135..","DOI":"10.1109\/IROS.2014.6942850"}],"container-title":["Journal of NeuroEngineering and Rehabilitation"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s12984-020-00673-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1186\/s12984-020-00673-7\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s12984-020-00673-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,4,8]],"date-time":"2021-04-08T23:21:55Z","timestamp":1617924115000},"score":1,"resource":{"primary":{"URL":"https:\/\/jneuroengrehab.biomedcentral.com\/articles\/10.1186\/s12984-020-00673-7"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,4,9]]},"references-count":58,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2020,12]]}},"alternative-id":["673"],"URL":"https:\/\/doi.org\/10.1186\/s12984-020-00673-7","relation":{},"ISSN":["1743-0003"],"issn-type":[{"value":"1743-0003","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,4,9]]},"assertion":[{"value":"8 October 2019","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"18 March 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"9 April 2020","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The study and experimental protocol were designed in accordance with the Swiss Federal Act on Research involving Human Beings. Based on the Swiss ethics guidelines for Technical Assistance Systems, the Ethics Committee Ostschweiz (EKOS) declared their non-competence to evaluate the study according to the Swiss Federal Act on Research involving Human Beings. Informed consent was obtained from the participant.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they have no competing interests.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"47"}}