{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,28]],"date-time":"2026-09-28T16:55:50Z","timestamp":1790614550151,"version":"4.1.0"},"reference-count":23,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2021,1,21]],"date-time":"2021-01-21T00:00:00Z","timestamp":1611187200000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2021,1,21]],"date-time":"2021-01-21T00:00:00Z","timestamp":1611187200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J NeuroEngineering Rehabil"],"published-print":{"date-parts":[[2021,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>Rapid onset of muscular fatigue is still one of the main issues of functional electrical stimulation (FES). A promising technique, known as distributed stimulation, aims to activate sub-units of a muscle at a lower stimulation frequency to increase fatigue-resistance. Besides a general agreement on the beneficial effects, the great heterogeneity of evaluation techniques, raises the demand for a standardized method to better reflect the requirements of a practical application.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>This study investigated the fatigue-development of 6 paralysed quadriceps muscles over the course of 180 dynamic contractions, evaluating different electrode-configurations (conventional and distributed stimulation). For a standardized comparison, fatigue-testing was performed at 40% of the peak-torque during a maximal evoked contraction (MEC). Further, we assessed the isometric torque for each electrode-configuration at different knee-extension-angles (70\u00b0\u2013170\u00b0, 10\u00b0 steps).<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>Our results showed no significant difference in the fatigue-index for any of the tested electrode-configurations, compared to conventional-stimulation. We conjecture that the positive effects of distributed stimulation become less pronounced at higher stimulation amplitudes. The isometric torque produced at different knee-extension angles was similar for most electrode-configurations. Maximal torque-production was found at 130\u00b0\u2013140\u00b0 knee-extension-angle, which correlates with the maximal knee-flexion-angles during running.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusion<\/jats:title>\n                <jats:p>In most practical applications, FES is intended to initiate dynamic movements. Therefore, it is crucial to assess fatigue-resistance by using dynamic contractions. Reporting the relationship between produced torque and knee-extension-angle can help to observe the stability of a chosen electrode-configuration for a targeted range-of-motion. Additionally, we suggest to perform fatigue testing at higher forces (e.g. 40% of the maximal evoked torque) in pre-trained subjects with SCI to better reflect the practical demands of FES-applications.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s12984-021-00805-7","type":"journal-article","created":{"date-parts":[[2021,1,21]],"date-time":"2021-01-21T08:03:06Z","timestamp":1611216186000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":19,"title":["Standardizing fatigue-resistance testing during electrical stimulation of paralysed human quadriceps muscles, a practical approach"],"prefix":"10.1186","volume":"18","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-6354-3879","authenticated-orcid":false,"given":"Martin","family":"Schmoll","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8236-8583","authenticated-orcid":false,"given":"Ronan","family":"Le Guillou","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6769-5359","authenticated-orcid":false,"given":"David","family":"Lobato Borges","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3042-0941","authenticated-orcid":false,"given":"Charles","family":"Fattal","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9858-9009","authenticated-orcid":false,"given":"Emerson","family":"Fachin-Martins","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7379-8004","authenticated-orcid":false,"given":"Christine","family":"Azevedo Coste","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2021,1,21]]},"reference":[{"key":"805_CR1","doi-asserted-by":"publisher","first-page":"294","DOI":"10.1310\/sci2104-294","volume":"21","author":"CS Bickel","year":"2015","unstructured":"Bickel CS, Yarar-Fisher C, Mahoney ET, McCully KK. Neuromuscular Electrical Stimulation-Induced Resistance Training After SCI: A Review of the Dudley Protocol. Top Spinal Cord Inj Rehabil. 2015;21:294.","journal-title":"Top Spinal Cord Inj Rehabil"},{"key":"805_CR2","doi-asserted-by":"publisher","first-page":"71","DOI":"10.1007\/s40279-014-0250-2","volume":"45","author":"G Deley","year":"2015","unstructured":"Deley G, Denuziller J, Babault N. Functional Electrical Stimulation: Cardiorespiratory Adaptations and Applications for Training in Paraplegia. Sports Med. 2015;45:71\u201382.","journal-title":"Sports Med"},{"key":"805_CR3","doi-asserted-by":"publisher","first-page":"336","DOI":"10.1111\/aor.13139","volume":"42","author":"CA Coste","year":"2018","unstructured":"Coste CA, Wolf P. FES-Cycling at Cybathlon 2016: Overview on Teams and Results. Artif Organs. 2018;42:336\u201341.","journal-title":"Artif Organs"},{"key":"805_CR4","doi-asserted-by":"publisher","first-page":"599","DOI":"10.1152\/jn.1965.28.3.599","volume":"28","author":"E Henneman","year":"1965","unstructured":"Henneman E, Somjen G, Carpenter DO. Excitability and Inhibitibility of Motoneurons of Different Sizes. J Neurophysiol. 1965;28:599\u2013620.","journal-title":"J Neurophysiol"},{"key":"805_CR5","doi-asserted-by":"publisher","first-page":"443","DOI":"10.1113\/jphysiol.1969.sp008923","volume":"204","author":"PMH Rack","year":"1969","unstructured":"Rack PMH, Westbury DR. The effects of length and stimulus rate on tension in the isometric cat soleus muscle. J Physiol. 1969;204:443\u201360.","journal-title":"J Physiol"},{"key":"805_CR6","doi-asserted-by":"publisher","first-page":"271","DOI":"10.1002\/mus.25465","volume":"56","author":"AJ Bergquist","year":"2017","unstructured":"Bergquist AJ, Babbar V, Ali S, Popovic MR, Masani K. Fatigue reduction during aggregated and distributed sequential stimulation. Muscle Nerve. 2017;56:271\u201381.","journal-title":"Muscle Nerve"},{"key":"805_CR7","unstructured":"Downey R, Ambrosini E, Ferrante E, Pedrocchi A, Dixon W, Ferrigno G. Asynchronous Stimulation with an Electrode Array Reduces NMES-Induced Muscle Fatigue during FES Cycling. Proc Int Func Elect Stimul Soc Banff Can. p. 154\u2013157. 2012. http:\/\/ifess2012.com\/papers\/oral\/secondary_complications_exercise_and_denervated_muscles\/asynchronous_stimulation_with_an_electrode_array_reduces_nmes-induced_muscle_fatigue_during_fes_cycling.html"},{"key":"805_CR8","doi-asserted-by":"publisher","first-page":"964","DOI":"10.1109\/TNSRE.2014.2364735","volume":"23","author":"RJ Downey","year":"2015","unstructured":"Downey RJ, Bellman MJ, Kawai H, Gregory CM, Dixon WE. Comparing the induced muscle fatigue between asynchronous and synchronous electrical stimulation in able-bodied and spinal cord injured populations. IEEE Trans Neural Syst Rehabil Eng. 2015;23:964\u201372.","journal-title":"IEEE Trans Neural Syst Rehabil Eng"},{"key":"805_CR9","doi-asserted-by":"publisher","first-page":"5","DOI":"10.1186\/s12984-018-0471-y","volume":"16","author":"M Laubacher","year":"2019","unstructured":"Laubacher M, Aksoez EA, Brust AK, Baumberger M, Riener R, Binder-Macleod S, et al. Stimulation of paralysed quadriceps muscles with sequentially and spatially distributed electrodes during dynamic knee extension. J NeuroEngineering Rehabil. 2019;16:5.","journal-title":"J NeuroEngineering Rehabil"},{"key":"805_CR10","doi-asserted-by":"publisher","first-page":"1787","DOI":"10.1007\/s00421-017-3675-0","volume":"117","author":"M Laubacher","year":"2017","unstructured":"Laubacher M, Aks\u00f6z AE, Riener R, Binder-Macleod S, Hunt KJ. Power output and fatigue properties using spatially distributed sequential stimulation in a dynamic knee extension task. Eur J Appl Physiol. 2017;117:1787\u201398.","journal-title":"Eur J Appl Physiol"},{"key":"805_CR11","doi-asserted-by":"publisher","first-page":"6016","DOI":"10.4081\/ejtm.2016.6016","volume":"26","author":"M Laubacher","year":"2016","unstructured":"Laubacher M, Aks\u00f6z EA, Binder-Macleod S, Hunt KJ. Comparison of Proximally Versus Distally Placed Spatially Distributed Sequential Stimulation Electrodes in a Dynamic Knee Extension Task. Eur J Transl Myol. 2016;26:6016.","journal-title":"Eur J Transl Myol"},{"key":"805_CR12","doi-asserted-by":"publisher","first-page":"556","DOI":"10.1002\/mus.21736","volume":"42","author":"NM Male\u0161evi\u0107","year":"2010","unstructured":"Male\u0161evi\u0107 NM, Popovi\u0107 LZ, Schwirtlich L, Popovi\u0107 DB. Distributed low-frequency functional electrical stimulation delays muscle fatigue compared to conventional stimulation. Muscle Nerve. 2010;42:556\u201362.","journal-title":"Muscle Nerve"},{"key":"805_CR13","doi-asserted-by":"crossref","unstructured":"Popovic LZ, Malesevic NM. Muscle fatigue of quadriceps in paraplegics: Comparison between single vs. multi-pad electrode surface stimulation. 2009 Annu Int Conf IEEE Eng Med Biol Soc. 2009. p. 6785\u20138.","DOI":"10.1109\/IEMBS.2009.5333983"},{"key":"805_CR14","doi-asserted-by":"publisher","first-page":"793","DOI":"10.1007\/s00421-013-2807-4","volume":"114","author":"DG Sayenko","year":"2014","unstructured":"Sayenko DG, Nguyen R, Popovic MR, Masani K. Reducing muscle fatigue during transcutaneous neuromuscular electrical stimulation by spatially and sequentially distributing electrical stimulation sources. Eur J Appl Physiol. 2014;114:793\u2013804.","journal-title":"Eur J Appl Physiol"},{"key":"805_CR15","volume-title":"Ausdauertraining: Grundlagen \u00b7 Methoden \u00b7 Trainingssteuerung","author":"F Zintl","year":"2009","unstructured":"Zintl F, Eisenhut A. Ausdauertraining: Grundlagen \u00b7 Methoden \u00b7 Trainingssteuerung. 7th ed. M\u00fcnchen: BLV Buchverlag GmbH & Co.; 2009.","edition":"7"},{"key":"805_CR16","doi-asserted-by":"publisher","first-page":"58","DOI":"10.1109\/MRA.2017.2751660","volume":"24","author":"APL Bo","year":"2017","unstructured":"Bo APL, da Fonseca LO, Guimaraes JA, Fachin-Martins E, Paredes MEG, Brindeiro GA, et al. Cycling with spinal cord injury: a novel system for cycling using electrical stimulation for individuals with paraplegia, and preparation for cybathlon 2016. IEEE Robot Autom Mag. 2017;24:58\u201365.","journal-title":"IEEE Robot Autom Mag"},{"key":"805_CR17","doi-asserted-by":"publisher","first-page":"1133","DOI":"10.1016\/S0003-9993(98)90184-8","volume":"79","author":"A Hartkopp","year":"1998","unstructured":"Hartkopp A, MurphyRen\u00e9 JL, Mohr T, Kjcer M, Biering-Sorensen F. Bone fracture during electrical stimulation of the quadriceps in a spinal cord injured subject. Arch Phys Med Rehabil. 1998;79:1133\u20136.","journal-title":"Arch Phys Med Rehabil."},{"key":"805_CR18","doi-asserted-by":"publisher","first-page":"1858","DOI":"10.1152\/jn.1998.79.4.1858","volume":"79","author":"SA Binder-Macleod","year":"1998","unstructured":"Binder-Macleod SA, Lee SC, Fritz AD, Kucharski LJ. New look at force-frequency relationship of human skeletal muscle: effects of fatigue. J Neurophysiol. 1998;79:1858\u201368.","journal-title":"J Neurophysiol"},{"key":"805_CR19","doi-asserted-by":"publisher","first-page":"195","DOI":"10.1046\/j.1365-201x.2001.00864.x","volume":"172","author":"SA Binder-Macleod","year":"2001","unstructured":"Binder-Macleod SA, Scott WB. Comparison of fatigue produced by various electrical stimulation trains. Acta Physiol Scand. 2001;172:195\u2013203.","journal-title":"Acta Physiol Scand"},{"key":"805_CR20","doi-asserted-by":"publisher","first-page":"122","DOI":"10.1126\/science.168.3927.122","volume":"168","author":"RE Burke","year":"1970","unstructured":"Burke RE, Rudomin P, Zajac FE. Catch property in single mammalian motor units. Science. 1970;168:122\u20134.","journal-title":"Science"},{"key":"805_CR21","doi-asserted-by":"publisher","first-page":"37","DOI":"10.1016\/j.gaitpost.2018.11.002","volume":"68","author":"AF Dos Santos","year":"2019","unstructured":"Dos Santos AF, Nakagawa TH, Serr\u00e3o FV, Ferber R. Patellofemoral joint stress measured across three different running techniques. Gait Posture. 2019;68:37\u201343.","journal-title":"Gait Posture"},{"key":"805_CR22","doi-asserted-by":"publisher","first-page":"122","DOI":"10.1080\/14763141.2015.1024716","volume":"14","author":"MA Bryanton","year":"2015","unstructured":"Bryanton MA, Carey JP, Kennedy MD, Chiu LZF. Quadriceps effort during squat exercise depends on hip extensor muscle strategy. Sports Biomech Routledge. 2015;14:122\u201338.","journal-title":"Sports Biomech Routledge"},{"key":"805_CR23","first-page":"184","volume":"15","author":"J Chow","year":"1999","unstructured":"Chow J, Darling W, Andrews H. Determining the force-length-velocity of the quadriceps muscles \u2013 III: a pilot study. J Appl Biomech. 1999;15:184\u201393.","journal-title":"J Appl Biomech."}],"container-title":["Journal of NeuroEngineering and Rehabilitation"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s12984-021-00805-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1186\/s12984-021-00805-7\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s12984-021-00805-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,1,21]],"date-time":"2021-01-21T08:08:22Z","timestamp":1611216502000},"score":1,"resource":{"primary":{"URL":"https:\/\/jneuroengrehab.biomedcentral.com\/articles\/10.1186\/s12984-021-00805-7"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,1,21]]},"references-count":23,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2021,12]]}},"alternative-id":["805"],"URL":"https:\/\/doi.org\/10.1186\/s12984-021-00805-7","relation":{},"ISSN":["1743-0003"],"issn-type":[{"value":"1743-0003","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,1,21]]},"assertion":[{"value":"3 August 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"11 January 2021","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"21 January 2021","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Ethical approval was obtained by the Ethics and Research Committee of the Faculty of Ceilandia, University of Bras\u00edlia, Bras\u00edlia, Brazil (CAAE: 09303218.6.0000.8093, Ethical Approval number 3.632.98). All procedures were performed in accordance with the ethical standards of the 1964 Declaration of Helsinki and its later amendments and gave written consent to participate.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"All participants gave consent for their measurement data to be used in this publication.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"11"}}