{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,1]],"date-time":"2026-09-01T02:06:42Z","timestamp":1788228402728,"version":"build-2803163510"},"reference-count":33,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2021,5,21]],"date-time":"2021-05-21T00:00:00Z","timestamp":1621555200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2021,5,21]],"date-time":"2021-05-21T00:00:00Z","timestamp":1621555200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100004243","name":"Prinses Beatrix Spierfonds","doi-asserted-by":"publisher","award":["W.O16-20"],"award-info":[{"award-number":["W.O16-20"]}],"id":[{"id":"10.13039\/501100004243","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J NeuroEngineering Rehabil"],"published-print":{"date-parts":[[2021,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>Neuromuscular disorders (NMD) commonly affect the upper extremity. Due to muscle weakness, performance of daily activities becomes increasingly difficult, which leads to reduced independence and quality of life. In order to support the performance of upper extremity tasks, dynamic arm supports may be used. The Yumen Arm is a novel dynamic arm support specially developed for people with NMD. The aim of this study is to evaluate the feasibility and effectiveness of the Yumen Arm in persons with Duchenne Muscular Dystrophy (DMD) and persons with Spinal Muscular Atrophy (SMA).<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>Three persons with DMD and three persons with SMA participated in this study. All participants conducted a set of measures with and without the Yumen Arm. Outcome measures were: active range of motion of the arm and trunk (i.e. Reachable Workspace, Functional Workspace, and trunk movement), fatigue (OMNI-RPE), Performance of Upper Limb (PUL) scale and some additional activities of daily living. User experiences were collected using a questionnaire.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>The Yumen Arm could be used by all participants. Results showed a median increase in active range of motion (4% relative surface area), and a median increase of function ability (&gt;\u200911% PUL score) when using the Yumen Arm. In addition, three out of four (data from 2 participants was missing) participants indicated that activity performance was less fatiguing when using the Yumen Arm. Four out of five (data from 1 participant was missing) participants indicated that they would like to use the Yumen Arm in their daily lives.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusion<\/jats:title>\n                <jats:p>This study is one of the first studies describing a range of objective measures to examine the effectiveness of a dynamic arm support. Based on these measurements we can conclude that the Yumen Arm effectively improves arm function in NMD patients, however the effectiveness varies a lot between individual subjects. We provided detailed recommendations for the improvement of the Yumen Arm, and possible also for the development of other dynamic arm supports. This study showed a lot of variability between individual subjects, which emphasizes the importance of tuning dynamic arm supports based on individual user characteristics, such as scoliosis, functional capacity and muscle strength.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s12984-021-00868-6","type":"journal-article","created":{"date-parts":[[2021,5,21]],"date-time":"2021-05-21T10:02:42Z","timestamp":1621591362000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":13,"title":["Feasibility and effectiveness of a novel dynamic arm support in persons with spinal muscular atrophy and duchenne muscular dystrophy"],"prefix":"10.1186","volume":"18","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-2715-6235","authenticated-orcid":false,"given":"Mariska M. H. P.","family":"Janssen","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jolinda","family":"Horstik","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Paulien","family":"Klap","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Imelda J. M.","family":"de Groot","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2021,5,21]]},"reference":[{"issue":"1","key":"868_CR1","doi-asserted-by":"publisher","first-page":"73","DOI":"10.3233\/JND-140045","volume":"2","author":"JC Deenen","year":"2015","unstructured":"Deenen JC, Horlings CG, Verschuuren JJ, Verbeek AL, van Engelen BG. The epidemiology of neuromuscular disorders: a comprehensive overview of the literature. J Neuromuscul Dis. 2015;2(1):73\u201385.","journal-title":"J Neuromuscul Dis"},{"key":"868_CR2","doi-asserted-by":"publisher","first-page":"1115","DOI":"10.1016\/j.nmd.2017.09.003","volume":"27","author":"A Bergsma","year":"2017","unstructured":"Bergsma A, Janssen MM, Geurts AC, Cup E, Groot IJM. Different profiles of upper limb function in four types of neuromuscular disorders. Neuromusc Disord. 2017;27:1115\u201322. https:\/\/doi.org\/10.1016\/j.nmd.2017.09.003.","journal-title":"Neuromusc Disord."},{"issue":"1\u20132","key":"868_CR3","doi-asserted-by":"publisher","first-page":"117","DOI":"10.1016\/j.jns.2006.02.018","volume":"246","author":"N Yozbatiran","year":"2006","unstructured":"Yozbatiran N, Baskurt F, Baskurt Z, Ozakbas S, Idiman E. Motor assessment of upper extremity function and its relation with fatigue, cognitive function and quality of life in multiple sclerosis patients. J Neurol Sci. 2006;246(1\u20132):117\u201322.","journal-title":"J Neurol Sci"},{"issue":"1","key":"868_CR4","doi-asserted-by":"publisher","first-page":"44","DOI":"10.1097\/PHM.0000000000000107","volume":"94","author":"LA van der Heide","year":"2015","unstructured":"van der Heide LA, Gelderblom GJ, de Witte LP. Effects and effectiveness of dynamic arm supports: a technical review. Am J Phys Med Rehabil. 2015;94(1):44\u201362.","journal-title":"Am J Phys Med Rehabil"},{"key":"868_CR5","first-page":"6650485","volume":"2013","author":"AG Dunning","year":"2013","unstructured":"Dunning AG, Herder JL. A review of assistive devices for arm balancing. IEEE Int Conf Rehabil Robot. 2013;2013:6650485.","journal-title":"IEEE Int Conf Rehabil Robot"},{"issue":"4","key":"868_CR6","doi-asserted-by":"publisher","first-page":"287","DOI":"10.1177\/0309364613498538","volume":"38","author":"LA Van der Heide","year":"2014","unstructured":"Van der Heide LA, van Ninhuijs B, Bergsma A, Gelderblom GJ, van der Pijl DJ, de Witte LP. An overview and categorization of dynamic arm supports for people with decreased arm function. Prosthet Orthot Int. 2014;38(4):287\u2013302.","journal-title":"Prosthet Orthot Int"},{"issue":"1","key":"868_CR7","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1080\/17483100600845414","volume":"2","author":"M Scherer","year":"2007","unstructured":"Scherer M, Jutai J, Fuhrer M, Demers L, Deruyter F. A framework for modelling the selection of assistive technology devices (ATDs). Disabil Rehabil Assist Technol. 2007;2(1):1\u20138.","journal-title":"Disabil Rehabil Assist Technol"},{"issue":"1\u20132","key":"868_CR8","doi-asserted-by":"publisher","first-page":"97","DOI":"10.1080\/09638280500167548","volume":"1","author":"BP Dijcks","year":"2006","unstructured":"Dijcks BP, De Witte LP, Gelderblom GJ, Wessels RD, Soede M. Non-use of assistive technology in The Netherlands: a non-issue? Disabil Rehabil Assist Technol. 2006;1(1\u20132):97\u2013102.","journal-title":"Disabil Rehabil Assist Technol"},{"issue":"6","key":"868_CR9","first-page":"675","volume":"37","author":"T Rahman","year":"2000","unstructured":"Rahman T, Sample W, Seliktar R, Alexander M, Scavina M. A body-powered functional upper limb orthosis. J Rehabil Res Dev. 2000;37(6):675\u201380.","journal-title":"J Rehabil Res Dev"},{"key":"868_CR10","doi-asserted-by":"publisher","DOI":"10.1115\/1.4034298","author":"AG Dunning","year":"2016","unstructured":"Dunning AG, Janssen MMHP, Kooren PN, Herder JL. Evaluation of an arm support with trunk motion capability. J Med Devices. 2016. https:\/\/doi.org\/10.1115\/1.4034298.","journal-title":"J Med Devices."},{"key":"868_CR11","doi-asserted-by":"publisher","first-page":"83","DOI":"10.1186\/s12984-015-0072-y","volume":"12","author":"PN Kooren","year":"2015","unstructured":"Kooren PN, Dunning AG, Janssen MM, Lobo-Prat J, Koopman BF, Paalman MI, et al. Design and pilot validation of A-gear: a novel wearable dynamic arm support. J Neuroeng Rehabil. 2015;12:83.","journal-title":"J Neuroeng Rehabil"},{"issue":"12","key":"868_CR12","doi-asserted-by":"publisher","first-page":"1115","DOI":"10.1016\/j.nmd.2017.09.003","volume":"27","author":"A Bergsma","year":"2017","unstructured":"Bergsma A, Janssen MMHP, Geurts ACH, Cup EHC, de Groot IJM. Different profiles of upper limb function in four types of neuromuscular disorders. Neuromuscul Disord. 2017;27(12):1115\u201322.","journal-title":"Neuromuscul Disord"},{"key":"868_CR13","doi-asserted-by":"publisher","first-page":"156","DOI":"10.1016\/j.mechmachtheory.2012.11.003","volume":"61","author":"P-Y Lin","year":"2013","unstructured":"Lin P-Y, Shieh W-B, Chen D-Z. A theoretical study of weight-balanced mechanisms for design of spring assistive mobile arm support (MAS). Mech Mach Theory. 2013;61:156\u201367.","journal-title":"Mech Mach Theory"},{"issue":"3","key":"868_CR14","doi-asserted-by":"publisher","first-page":"186","DOI":"10.1002\/mus.880040304","volume":"4","author":"MH Brooke","year":"1981","unstructured":"Brooke MH, Griggs RC, Mendell JR, Fenichel GM, Shumate JB, Pellegrino RJ. Clinical trial in Duchenne dystrophy. I. The design of the protocol. Muscle Nerve. 1981;4(3):186\u201397.","journal-title":"Muscle Nerve."},{"key":"868_CR15","volume-title":"ICF: International classification of functioning, disability and health\/World Health Organization","author":"World Health O","year":"2001","unstructured":"World Health O. ICF: International classification of functioning, disability and health\/World Health Organization. Geneva: World Health Organization; 2001."},{"issue":"2","key":"868_CR16","doi-asserted-by":"publisher","first-page":"333","DOI":"10.1249\/01.MSS.0000048831.15016.2A","volume":"35","author":"RJ Robertson","year":"2003","unstructured":"Robertson RJ, Goss FL, Rutkowski J, Lenz B, Dixon C, Timmer J, et al. Concurrent validation of the OMNI perceived exertion scale for resistance exercise. Med Sci Sports Exerc. 2003;35(2):333\u201341.","journal-title":"Med Sci Sports Exerc"},{"issue":"3","key":"868_CR17","doi-asserted-by":"publisher","first-page":"344","DOI":"10.1002\/mus.24567","volume":"52","author":"JJ Han","year":"2015","unstructured":"Han JJ, Kurillo G, Abresch RT, De Bie E, Nicorici A, Bajcsy R. Upper extremity 3-dimensional reachable workspace analysis in dystrophinopathy using Kinect. Muscle Nerve. 2015;52(3):344\u201355.","journal-title":"Muscle Nerve"},{"issue":"6","key":"868_CR18","doi-asserted-by":"publisher","first-page":"641","DOI":"10.3233\/THC-130764","volume":"21","author":"G Kurillo","year":"2013","unstructured":"Kurillo G, Chen A, Bajcsy R, Han JJ. Evaluation of upper extremity reachable workspace using Kinect camera. Technol Health Care. 2013;21(6):641\u201356.","journal-title":"Technol Health Care"},{"issue":"2","key":"868_CR19","doi-asserted-by":"publisher","first-page":"168","DOI":"10.1002\/mus.24287","volume":"51","author":"JJ Han","year":"2015","unstructured":"Han JJ, Kurillo G, Abresch RT, de Bie E, Nicorici A, Bajcsy R. Reachable workspace in facioscapulohumeral muscular dystrophy (FSHD) by Kinect. Muscle Nerve. 2015;51(2):168\u201375.","journal-title":"Muscle Nerve"},{"issue":"11","key":"868_CR20","doi-asserted-by":"publisher","first-page":"3285","DOI":"10.1109\/JBHI.2020.2989722","volume":"24","author":"RP Matthew","year":"2020","unstructured":"Matthew RP, Seko S, Kurillo G, Bajcsy R, Cheng L, Han JJ, et al. Reachable workspace and proximal function measures for quantifying upper limb motion. IEEE J Biomed Health Inform. 2020;24(11):3285\u201394.","journal-title":"IEEE J Biomed Health Inform"},{"issue":"1","key":"868_CR21","doi-asserted-by":"publisher","first-page":"44","DOI":"10.1186\/s12984-019-0515-y","volume":"16","author":"LHC Peeters","year":"2019","unstructured":"Peeters LHC, Kingma I, van Dieen JH, de Groot IJM. Don\u2019t forget the trunk in Duchenne muscular dystrophy patients: more muscle weakness and compensation than expected. J Neuroeng Rehabil. 2019;16(1):44.","journal-title":"J Neuroeng Rehabil"},{"issue":"11","key":"868_CR22","doi-asserted-by":"publisher","first-page":"1038","DOI":"10.1111\/dmcn.12213","volume":"55","author":"A Mayhew","year":"2013","unstructured":"Mayhew A, Mazzone ES, Eagle M, Duong T, Ash M, Decostre V, et al. Development of the performance of the upper limb module for duchenne muscular dystrophy. Dev Med Child Neurol. 2013;55(11):1038\u201345.","journal-title":"Dev Med Child Neurol"},{"issue":"7","key":"868_CR23","doi-asserted-by":"publisher","first-page":"1269","DOI":"10.1007\/s00415-014-7316-9","volume":"261","author":"MM Janssen","year":"2014","unstructured":"Janssen MM, Bergsma A, Geurts AC, de Groot IJ. Patterns of decline in upper limb function of boys and men with DMD: an international survey. J Neurol. 2014;261(7):1269\u201388.","journal-title":"J Neurol"},{"issue":"1","key":"868_CR24","doi-asserted-by":"publisher","first-page":"107","DOI":"10.1186\/s12874-017-0391-8","volume":"17","author":"T Mathes","year":"2017","unstructured":"Mathes T, Pieper D. Clarifying the distinction between case series and cohort studies in systematic reviews of comparative studies: potential impact on body of evidence and workload. BMC Med Res Methodol. 2017;17(1):107.","journal-title":"BMC Med Res Methodol"},{"issue":"1","key":"868_CR25","doi-asserted-by":"publisher","first-page":"45","DOI":"10.1186\/s12984-017-0259-5","volume":"14","author":"M Janssen","year":"2017","unstructured":"Janssen M, Harlaar J, Koopman B, de Groot IJM. Dynamic arm study: quantitative description of upper extremity function and activity of boys and men with duchenne muscular dystrophy. J Neuroeng Rehabil. 2017;14(1):45.","journal-title":"J Neuroeng Rehabil"},{"issue":"6","key":"868_CR26","doi-asserted-by":"publisher","first-page":"e0199223","DOI":"10.1371\/journal.pone.0199223","volume":"13","author":"M Pane","year":"2018","unstructured":"Pane M, Coratti G, Brogna C, Mazzone ES, Mayhew A, Fanelli L, et al. Upper limb function in Duchenne muscular dystrophy: 24 month longitudinal data. PLoS ONE. 2018;13(6):e0199223.","journal-title":"PLoS ONE"},{"key":"868_CR27","first-page":"5975444","volume":"2011","author":"Y Hasegawa","year":"2011","unstructured":"Hasegawa Y, Oura S. Exoskeletal meal assistance system (EMAS II) for progressive muscle dystrophy patient. IEEE Int Conf Rehabil Robot. 2011;2011:5975444.","journal-title":"IEEE Int Conf Rehabil Robot"},{"issue":"5","key":"868_CR28","doi-asserted-by":"publisher","first-page":"e44","DOI":"10.1097\/BPO.0b013e31821f50b5","volume":"31","author":"T Haumont","year":"2011","unstructured":"Haumont T, Rahman T, Sample W, King MM, Church C, Henley J, et al. Wilmington robotic exoskeleton: a novel device to maintain arm improvement in muscular disease. J Pediatr Orthop. 2011;31(5):e44\u20139.","journal-title":"J Pediatr Orthop."},{"key":"868_CR29","doi-asserted-by":"crossref","unstructured":"Kramer G, R\u00f6mer GRBE, Struyt HJA. Design of a Dynamic Arm Support (DAS) for gravity compensation. 10th International Conference on Rehabilitation Robotics; June 12\u201315 2007; Noordwijk, The Netherlands: Proceedings of the 2007 IEEE; 2007.","DOI":"10.1109\/ICORR.2007.4428552"},{"key":"868_CR30","doi-asserted-by":"crossref","unstructured":"Mastenbroek B, Haan de E, Berg van den M, Herder JL, editors. Development of a Mobile Arm Support (Armon): Design Evolution and Preliminary User Experience. Proceedings of the 2007 IEEE 10th International Conference on Rehabilitation Robotics; 2007; Noordwijk, The Netherlands.","DOI":"10.1109\/ICORR.2007.4428563"},{"key":"868_CR31","unstructured":"Herder JL. Development of a Statically Balanced Arm Support: ARMON. 9th International Conference on Rehabilitation Robotics; June 28\u2013July 1, 2005; Chicago, USA2005."},{"key":"868_CR32","doi-asserted-by":"crossref","unstructured":"Lund K, Brandt R, Gelderblom G, Herder JL, editors. A user-centered evaluation study of a mobile arm support. 2009 IEEE International Conference on Rehabilitation Robotics; 2009 23\u201326 June 2009.","DOI":"10.1109\/ICORR.2009.5209494"},{"key":"868_CR33","doi-asserted-by":"crossref","unstructured":"Estilow T, Glanzman AM, Powers K, Moll A, Flickinger J, Medne L, et al. Use of the Wilmington robotic exoskeleton to improve upper extremity function in patients with duchenne muscular dystrophy. Am J Occupational Ther. 2018;72(2):7202345010p1-p5.","DOI":"10.5014\/ajot.2018.022939"}],"container-title":["Journal of NeuroEngineering and Rehabilitation"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12984-021-00868-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12984-021-00868-6\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12984-021-00868-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,5,21]],"date-time":"2021-05-21T10:03:14Z","timestamp":1621591394000},"score":1,"resource":{"primary":{"URL":"https:\/\/jneuroengrehab.biomedcentral.com\/articles\/10.1186\/s12984-021-00868-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,5,21]]},"references-count":33,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2021,12]]}},"alternative-id":["868"],"URL":"https:\/\/doi.org\/10.1186\/s12984-021-00868-6","relation":{},"ISSN":["1743-0003"],"issn-type":[{"value":"1743-0003","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,5,21]]},"assertion":[{"value":"10 December 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"20 April 2021","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"21 May 2021","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This study was approved by the medical ethical committee of Arnhem\u2013Nijmegen in the Netherlands (Registration Number NL58988.091.16). Informed consent was obtained from all participants and, in the cases where the participants were under 18\u00a0years of age, from their parents as well.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"We wish to disclose financial competing interests for the authors JH and PK. They both are employed by Yumen Bionics, the commercial organization that is further developing the prototype examined in this study. There was no financial contribution from Yumen Bionics for this project, however they provided us with the prototypes used in this study.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"84"}}