{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,16]],"date-time":"2026-10-16T15:53:42Z","timestamp":1792166022120,"version":"4.4.0"},"reference-count":28,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2023,1,22]],"date-time":"2023-01-22T00:00:00Z","timestamp":1674345600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2023,1,22]],"date-time":"2023-01-22T00:00:00Z","timestamp":1674345600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/100000090","name":"Congressionally Directed Medical Research Programs","doi-asserted-by":"publisher","award":["W81XWH-21-2-0049"],"award-info":[{"award-number":["W81XWH-21-2-0049"]}],"id":[{"id":"10.13039\/100000090","id-type":"DOI","asserted-by":"publisher"}]},{"name":"DoD-VA Extremity Trauma and Amputation Center of Excellence","award":["HU00012020038"],"award-info":[{"award-number":["HU00012020038"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J NeuroEngineering Rehabil"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>The mechanical properties of an ankle\u2013foot orthosis (AFO) play an important role in the gait mechanics of the end user. However, testing methodologies for evaluating these mechanical properties are not standardized.  The purpose of this study was to compare five different evaluation frameworks to assess AFO stiffness.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Method<\/jats:title>\n                    <jats:p>The same 13 carbon composite AFOs were tested with five different methods. Four previously reported custom test fixtures (the BRUCE, KST, SMApp, and EMPIRE) rotated an AFO into dorsiflexion about a defined axis in the sagittal plane. The fifth method involved quasi-static deflection of AFOs into dorsiflexion by hanging weights (HW) from the footplate. AFO rotational stiffness was calculated as the linear fit of the AFO resistive torque and angular deflection. Differences between methods were assessed using descriptive statistics and a repeated measures Friedman with post-hoc Bonferroni\u2013Holm adjusted Wilcoxon signed-rank tests.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>There were significant differences in measured AFO stiffnesses between test methods. Specifically, the BRUCE and HW methods measured lower stiffness than both the EMPIRE and the KST. Stiffnesses measured by the SMApp were not significantly different than any test method. Stiffnesses were lowest in the HW method, where motion was not constrained to a single plane. The median difference in absolute AFO stiffness across methods was 1.03 Nm\/deg with a range of [0.40 to 2.35] Nm\/deg. The median relative percent difference, measured as the range of measured stiffness from the five methods over the average measured stiffness was 62% [range 13% to 156%]. When the HW method was excluded, the four previously reported test fixtures produced a median difference in absolute AFO stiffness of 0.52 [range 0.38 to 2.17] Nm\/deg with a relative percent difference between the methods of 27% [range 13% to 89%].<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>This study demonstrates the importance of developing mechanical testing standards, similar to those that exist for lower limb prosthetics. Lacking standardization, differences in methodology can result in large differences in measured stiffness, particularly for different constraints on motion. Non-uniform measurement practices may limit the clinical utility of AFO stiffness as a metric in AFO prescription and future research.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s12984-023-01126-7","type":"journal-article","created":{"date-parts":[[2023,1,22]],"date-time":"2023-01-22T04:02:23Z","timestamp":1674360143000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":24,"title":["Comparison of five different methodologies for evaluating ankle\u2013foot orthosis stiffness"],"prefix":"10.1186","volume":"20","author":[{"given":"Benjamin R.","family":"Shuman","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Deema","family":"Totah","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Deanna H.","family":"Gates","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fan","family":"Gao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andrew J.","family":"Ries","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Elizabeth","family":"Russell Esposito","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2023,1,22]]},"reference":[{"key":"1126_CR1","doi-asserted-by":"publisher","first-page":"101","DOI":"10.1016\/j.gaitpost.2019.01.020","volume":"69","author":"D Totah","year":"2019","unstructured":"Totah D, Menon M, Jones-Hershinow C, Barton K, Gates DH. The impact of ankle-foot orthosis stiffness on gait: a systematic literature review. Gait Posture. 2019;69:101\u201311.","journal-title":"Gait Posture"},{"key":"1126_CR2","volume-title":"Report of a Concensus Conference on the Orthotic Management of Stroke Patients","author":"E Condie","year":"2004","unstructured":"Condie E. Report of a Concensus Conference on the Orthotic Management of Stroke Patients. 1st ed. Copenhagen: International Society for Prosthetics and Orthotics; 2004.","edition":"1"},{"key":"1126_CR3","doi-asserted-by":"publisher","first-page":"922","DOI":"10.1016\/j.pmrj.2015.03.005","volume":"7","author":"AJ Ries","year":"2015","unstructured":"Ries AJ, Novacheck TF, Schwartz MH. The efficacy of ankle-foot orthoses on improving the gait of children with diplegic cerebral palsy\u202f: a multiple outcome analysis. PM R. 2015;7:922\u20139.","journal-title":"PM R"},{"key":"1126_CR4","doi-asserted-by":"publisher","first-page":"339","DOI":"10.1177\/0309364618824452","volume":"43","author":"A Ielapi","year":"2019","unstructured":"Ielapi A, Forward M, De BM. Computational and experimental evaluation of the mechanical properties of ankle foot orthoses: a literature review. Prosthet Orthot Int. 2019;43:339\u201348.","journal-title":"Prosthet Orthot Int"},{"key":"1126_CR5","doi-asserted-by":"publisher","first-page":"565","DOI":"10.1682\/JRRD.2010.10.0193","volume":"48","author":"T Kobayashi","year":"2011","unstructured":"Kobayashi T, Leung AKL, Hutchins SW. Techniques to measure rigidity of ankle-foot orthosis: a review. J Rehabil Res Dev. 2011;48:565\u201376.","journal-title":"J Rehabil Res Dev"},{"key":"1126_CR6","doi-asserted-by":"publisher","first-page":"144","DOI":"10.1016\/j.gaitpost.2009.05.012","volume":"30","author":"DJJ Bregman","year":"2009","unstructured":"Bregman DJJ, Rozumalski A, Koops D, De GV, Schwartz M, Harlaar J. A new method for evaluating ankle foot orthosis characteristics: BRUCE. Gait Posture. 2009;30:144\u20139.","journal-title":"Gait Posture"},{"key":"1126_CR7","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s13104-018-3752-4","volume":"11","author":"A Ielapi","year":"2018","unstructured":"Ielapi A, Vasiliauskaite E, Hendrickx M, Forward M, Lammens N, Van Paepegem W, et al. A novel experimental setup for evaluating the stiffness of ankle foot orthoses. BMC Res Notes. 2018;11:1\u20137.","journal-title":"BMC Res Notes"},{"key":"1126_CR8","doi-asserted-by":"publisher","first-page":"132","DOI":"10.3109\/03093649609164431","volume":"20","author":"T Sumiya","year":"1996","unstructured":"Sumiya T, Suzuki Y, Kasahara T. Stiffness control in posterior-type plastic ankle-foot orthoses: effect of ankle trimline Part 2: orthosis characteristics and orthosis\/patient matching. Prosthet Orthot Int. 1996;20:132\u20137.","journal-title":"Prosthet Orthot Int"},{"key":"1126_CR9","doi-asserted-by":"publisher","first-page":"212","DOI":"10.1038\/nature14288","volume":"522","author":"SH Collins","year":"2015","unstructured":"Collins SH, Wiggin MB, Sawicki GS. Reducing the energy cost of human walking using an unpowered exoskeleton. Nature. 2015;522:212\u20135.","journal-title":"Nature"},{"key":"1126_CR10","doi-asserted-by":"crossref","unstructured":"Gao F, Carlton W, Kapp S. Development of a Motorized Device for Quantitative Investigation of Articulated AFO Misalignment. 2010 4th International Conference on Bioinformatics and Biomedical Engineering. IEEE; 2010. p. 1\u20134.","DOI":"10.1109\/ICBBE.2010.5514982"},{"key":"1126_CR11","doi-asserted-by":"publisher","first-page":"102572","DOI":"10.1016\/j.mechatronics.2021.102572","volume":"77","author":"D Totah","year":"2021","unstructured":"Totah D, Menon M, Gates DH, Barton K. Design and evaluation of the SMApp: a stiffness measurement apparatus for ankle\u2013foot orthoses. Mechatronics. 2021;77:102572.","journal-title":"Mechatronics"},{"key":"1126_CR12","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1115\/1.4051845","volume":"144","author":"BR Shuman","year":"2022","unstructured":"Shuman BR, Russell EE. Multiplanar stiffness of commercial carbon composite ankle-foot orthoses. J Biomech Eng. 2022;144:1\u20138.","journal-title":"J Biomech Eng"},{"key":"1126_CR13","unstructured":"Prosthetics\u2014Structural testing of lower-limb prostheses\u2014Requirements and test methods. ISO 10328:2016(E)."},{"key":"1126_CR14","unstructured":"Prosthetics\u2014Testing of ankle-foot devices and foot units\u2014Requirements and test methods. ISO 22675:2016(E)."},{"key":"1126_CR15","unstructured":"Hochmann. Testing procedures for ankle-foot orthoses. Orthop\u00e4die-Technik. 2014;102\u20134."},{"key":"1126_CR16","unstructured":"Thuasne. SpryStep-Plus-Max Info Sheet. 2018. p. 1\u201323. https:\/\/www.pelsupply.com\/static\/related_files\/6165\/SpryStep-Plus-Max_InfoSheetPEL.pdf. Accessed 27 Oct 2020"},{"key":"1126_CR17","doi-asserted-by":"publisher","first-page":"784","DOI":"10.1109\/TBME.2007.912638","volume":"55","author":"MC Faustini","year":"2008","unstructured":"Faustini MC, Neptune RR, Crawford RH, Stanhope SJ. Manufacture of passive dynamic ankle\u2013foot orthoses using selective laser sintering. IEEE Trans Biomed Eng. 2008;55:784\u201390.","journal-title":"IEEE Trans Biomed Eng"},{"key":"1126_CR18","doi-asserted-by":"publisher","first-page":"1","DOI":"10.3390\/bioengineering4040095","volume":"4","author":"A Amerinatanzi","year":"2017","unstructured":"Amerinatanzi A, Zamanian H, Moghaddam NS, Jahadakbar A, Elahinia M. Application of the superelastic NiTi spring in ankle foot orthosis (AFO ) to create normal ankle joint behavior. Bioengineering. 2017;4:1\u201317.","journal-title":"Bioengineering"},{"key":"1126_CR19","doi-asserted-by":"publisher","first-page":"40","DOI":"10.1177\/0954411914566630","volume":"229","author":"E Papi","year":"2015","unstructured":"Papi E, Maclean J, Bowers RJ, Solomonidis SE. Determination of loads carried by polypropylene ankle\u2013foot orthoses: a preliminary study. J Eng Med. 2015;229:40\u201351.","journal-title":"J Eng Med"},{"key":"1126_CR20","first-page":"65","volume":"6","author":"S Holm","year":"1979","unstructured":"Holm S. A simple sequentially rejective multiple test procedure. Scand J Stat. 1979;6:65\u201370.","journal-title":"Scand J Stat"},{"key":"1126_CR21","doi-asserted-by":"publisher","first-page":"565","DOI":"10.1038\/s41592-019-0470-3","volume":"16","author":"J Ho","year":"2019","unstructured":"Ho J, Tumkaya T, Aryal S, Choi H, Claridge-Chang A. Moving beyond P values: data analysis with estimation graphics. Nat Methods. 2019;16:565\u20136.","journal-title":"Nat Methods"},{"key":"1126_CR22","doi-asserted-by":"publisher","first-page":"110483","DOI":"10.1016\/j.jbiomech.2021.110483","volume":"123","author":"D Totah","year":"2021","unstructured":"Totah D, Barton K, Gates DH. The effect of rotational speed on ankle-foot orthosis properties. J Biomech. 2021;123:110483.","journal-title":"J Biomech"},{"key":"1126_CR23","doi-asserted-by":"publisher","first-page":"98","DOI":"10.1097\/JPO.0b013e31812e555e","volume":"19","author":"TF Novacheck","year":"2007","unstructured":"Novacheck TF, Beattie C, Rozumalski A, Gent G, Kroll G. Quantifying the spring-like properties of ankle-foot orthoses (AFOs). J Prosthet Orthot. 2007;19:98\u2013103.","journal-title":"J Prosthet Orthot"},{"key":"1126_CR24","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1115\/1.4024825","volume":"135","author":"ES Schrank","year":"2013","unstructured":"Schrank ES, Hitch L, Wallace K, Moore R, Stanhope SJ. Assessment of a virtual functional prototyping process for the rapid manufacture of passive-dynamic ankle-foot orthoses. J Biomech Eng. 2013;135:1\u20137.","journal-title":"J Biomech Eng"},{"key":"1126_CR25","doi-asserted-by":"publisher","first-page":"181","DOI":"10.1177\/0309364611409617","volume":"35","author":"F Gao","year":"2011","unstructured":"Gao F, Carlton W, Kapp S. Effects of joint alignment and type on mechanical properties of thermoplastic articulated ankle-foot orthosis. Prosthet Orthot Int. 2011;35:181\u20139.","journal-title":"Prosthet Orthot Int"},{"key":"1126_CR26","doi-asserted-by":"publisher","first-page":"211","DOI":"10.1097\/JPO.0b013e3181f46822","volume":"22","author":"KZ Takahashi","year":"2010","unstructured":"Takahashi KZ, Stanhope SJ. Estimates of stiffness for ankle-foot orthoses are sensitive to loading conditions. J Prosthet Orthot. 2010;22:211\u20139.","journal-title":"J Prosthet Orthot"},{"key":"1126_CR27","doi-asserted-by":"publisher","first-page":"1025","DOI":"10.1115\/1.2049313","volume":"127","author":"P Cappa","year":"2005","unstructured":"Cappa P, Patane F, Di Rosa G. A Continuous loading apparatus for measuring three-dimensional stiffness of ankle-foot orthoses. J Biomech Eng. 2005;127:1025\u20139.","journal-title":"J Biomech Eng"},{"key":"1126_CR28","doi-asserted-by":"publisher","first-page":"2949","DOI":"10.1109\/TBME.2017.2691308","volume":"64","author":"AF Azocar","year":"2017","unstructured":"Azocar AF, Rouse EJ. Stiffness perception during active ankle and knee movement. IEEE Trans Biomed Eng IEEE. 2017;64:2949\u201356.","journal-title":"IEEE Trans Biomed Eng IEEE"}],"container-title":["Journal of NeuroEngineering and Rehabilitation"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12984-023-01126-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12984-023-01126-7\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12984-023-01126-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,1,22]],"date-time":"2023-01-22T04:03:29Z","timestamp":1674360209000},"score":1,"resource":{"primary":{"URL":"https:\/\/jneuroengrehab.biomedcentral.com\/articles\/10.1186\/s12984-023-01126-7"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,1,22]]},"references-count":28,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2023,12]]}},"alternative-id":["1126"],"URL":"https:\/\/doi.org\/10.1186\/s12984-023-01126-7","relation":{},"ISSN":["1743-0003"],"issn-type":[{"value":"1743-0003","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,1,22]]},"assertion":[{"value":"7 January 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"7 January 2023","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"22 January 2023","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The view(s) expressed herein are those of the author(s) and do not reflect the official policy or position of the Henry M. Jackson Foundation for the Advancement of Military Medicine, Inc., the U.S. Army Medical Department, the U.S. Army Office of the Surgeon General the Department of the Army or the Department of Defense or the U.S. Government.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"No human participants, human data, or human tissue were used in this study.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"No identifiable data is presented in this study.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no conflict of interest.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"11"}}