{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,16]],"date-time":"2026-10-16T23:38:40Z","timestamp":1792193920036,"version":"4.4.0"},"reference-count":80,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2023,10,5]],"date-time":"2023-10-05T00:00:00Z","timestamp":1696464000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2023,10,5]],"date-time":"2023-10-05T00:00:00Z","timestamp":1696464000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Korean government (MSIT) , National Research Foundation of Korea","award":["2022M3C1A3081359"],"award-info":[{"award-number":["2022M3C1A3081359"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J NeuroEngineering Rehabil"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Most partial hand amputees experience limited wrist movement. The limited rotational wrist movement deteriorates natural upper limb system related to hand use and the usability of the prosthetic hand, which may cause secondary damage to the musculoskeletal system due to overuse of the upper limb affected by repetitive compensatory movement patterns. Nevertheless, partial hand prosthetics, in common, have only been proposed without rotational wrist movement because patients have various hand shapes, and a prosthetic hand should be attached to a narrow space.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>We hypothesized that partial hand amputees, when using a prosthetic hand with a wrist rotation module, would achieve natural upper limb movement muscle synergy and motion analysis comparable to a control group. To validate the proposed prototype design with the wrist rotation module and verify our hypothesis, we compared a control group with partial hand amputees wearing hand prostheses, both with and without the wrist rotation module prototype. The study contained muscle synergy analysis through non-negative matrix factorization (NMF) using surface electromyography (sEMG) and motion analyses employing a motion capture system during the reach-to-grasp task. Additionally, we assessed the usability of the prototype design for partial hand amputees using the Jebsen-Taylor hand function test (JHFT).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>The results showed that the number of muscle synergies identified through NMF remained consistent at 3 for both the control group and amputees using a hand prosthesis with a wrist rotation module. In the motion analysis, a statistically significant difference was observed between the control group and the prosthetic hand without the wrist rotation module, indicating the presence of compensatory movements when utilizing a prosthetic hand lacking this module. Furthermore, among the amputees, the JHFT demonstrated a greater improvement in total score when using the prosthetic hand equipped with a wrist rotation module compared to the prosthetic hand without this module.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>In conclusion, integrating a wrist rotation module in prosthetic hand designs for partial hand amputees restores natural upper limb movement patterns, reduces compensatory movements, and prevent the secondary musculoskeletal. This highlights the importance of this module in enhancing overall functionality and quality of life.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s12984-023-01259-9","type":"journal-article","created":{"date-parts":[[2023,10,5]],"date-time":"2023-10-05T02:01:38Z","timestamp":1696471298000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":11,"title":["Restoring natural upper limb movement through a wrist prosthetic module for partial hand amputees"],"prefix":"10.1186","volume":"20","author":[{"given":"Seoyoung","family":"Choi","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wonwoo","family":"Cho","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Keehoon","family":"Kim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2023,10,5]]},"reference":[{"key":"1259_CR1","first-page":"127","volume-title":"Prosthetic restoration and rehabilitation of the upper and lower extremity","author":"A Giladi","year":"2013","unstructured":"Giladi A, Chung K. Surgical principles and perspectives on upper extremity amputations. In: Prosthetic restoration and rehabilitation of the upper and lower extremity. 1st ed. New York City, USA: Demos Medical Publishing; 2013. p. 127\u201340."},{"issue":"3","key":"1259_CR2","doi-asserted-by":"crossref","first-page":"422","DOI":"10.1016\/j.apmr.2007.11.005","volume":"89","author":"K Ziegler-Graham","year":"2008","unstructured":"Ziegler-Graham K, MacKenzie EJ, Ephraim PL, Travison TG, Brookmeyer R. Estimating the prevalence of limb loss in the United States: 2005 to 2050. Arch Phys Med Rehabil. 2008;89(3):422\u20139.","journal-title":"Arch Phys Med Rehabil"},{"issue":"1","key":"1259_CR3","doi-asserted-by":"crossref","first-page":"66","DOI":"10.1177\/0309364617691622","volume":"42","author":"B Maat","year":"2018","unstructured":"Maat B, Smit G, Plettenburg D, Breedveld P. Passive prosthetic hands and tools: a literature review. Prosthet Orthot Int. 2018;42(1):66\u201374.","journal-title":"Prosthet Orthot Int"},{"key":"1259_CR4","doi-asserted-by":"crossref","first-page":"209","DOI":"10.3389\/fnins.2016.00209","volume":"10","author":"F Cordella","year":"2016","unstructured":"Cordella F, Ciancio AL, Sacchetti R, Davalli A, Cutti AG, Guglielmelli E, et al. Literature review on needs of upper limb prosthesis users. Front Neurosci. 2016;10:209.","journal-title":"Front Neurosci"},{"issue":"10","key":"1259_CR5","doi-asserted-by":"crossref","first-page":"1157","DOI":"10.1016\/S0094-114X(01)00035-0","volume":"36","author":"N Dechev","year":"2001","unstructured":"Dechev N, Cleghorn W, Naumann S. Multiple finger, passive adaptive grasp prosthetic hand. Mech Mach Theory. 2001;36(10):1157\u201373.","journal-title":"Mech Mach Theory"},{"key":"1259_CR6","unstructured":"Massa B, Roccella S, Carrozza MC, Dario P, editors. Design and development of an underactuated prosthetic hand. Proceedings 2002 IEEE international conference on robotics and automation (Cat No 02CH37292); 2002: IEEE."},{"key":"1259_CR7","first-page":"388","volume":"35","author":"R Doshi","year":"1998","unstructured":"Doshi R, Yeh C, LeBlanc M. The design and development of a gloveless endoskeletal prosthetic hand. J Rehabil Res Dev. 1998;35:388\u201395.","journal-title":"J Rehabil Res Dev"},{"key":"1259_CR8","doi-asserted-by":"crossref","unstructured":"Kargov A, Pylatiuk C, Oberle R, Klosek H, Werner T, Roessler W, et al., editors. Development of a multifunctional cosmetic prosthetic hand. 2007 IEEE 10th international conference on rehabilitation robotics; 2007: IEEE.","DOI":"10.1109\/ICORR.2007.4428479"},{"issue":"1","key":"1259_CR9","doi-asserted-by":"crossref","first-page":"170","DOI":"10.1109\/TRO.2007.910708","volume":"24","author":"C Cipriani","year":"2008","unstructured":"Cipriani C, Zaccone F, Micera S, Carrozza MC. On the shared control of an EMG-controlled prosthetic hand: analysis of user\u2013prosthesis interaction. IEEE Trans Rob. 2008;24(1):170\u201384.","journal-title":"IEEE Trans Rob"},{"issue":"2","key":"1259_CR10","doi-asserted-by":"crossref","first-page":"309","DOI":"10.1088\/0967-3334\/24\/2\/307","volume":"24","author":"R Boostani","year":"2003","unstructured":"Boostani R, Moradi MH. Evaluation of the forearm EMG signal features for the control of a prosthetic hand. Physiol Meas. 2003;24(2):309.","journal-title":"Physiol Meas"},{"key":"1259_CR11","doi-asserted-by":"crossref","first-page":"247","DOI":"10.2147\/MDER.S91102","volume":"9","author":"P Geethanjali","year":"2016","unstructured":"Geethanjali P. Myoelectric control of prosthetic hands: state-of-the-art review. Med Devices Evid Res. 2016; 9: 247\u201355.","journal-title":"Med Devices Evid Res."},{"key":"1259_CR12","doi-asserted-by":"crossref","DOI":"10.1007\/978-3-642-18812-1","volume-title":"Powered upper limb prostheses: control, implementation and clinical application","author":"A Muzumdar","year":"2004","unstructured":"Muzumdar A. Powered upper limb prostheses: control, implementation and clinical application. Berlin: Springer; 2004."},{"issue":"6","key":"1259_CR13","first-page":"1188","volume":"26","author":"P Wattanasiri","year":"2018","unstructured":"Wattanasiri P, Tangpornprasert P, Virulsri C. Design of multi-grip patterns prosthetic hand with single actuator. IEEE Trans Neural Syst Rehabil Eng. 2018;26(6):1188\u201398.","journal-title":"IEEE Trans Neural Syst Rehabil Eng"},{"issue":"3","key":"1259_CR14","doi-asserted-by":"crossref","first-page":"609","DOI":"10.1109\/TNSRE.2018.2800162","volume":"26","author":"K Xu","year":"2018","unstructured":"Xu K, Liu H, Zhang Z, Zhu X. Wrist-powered partial hand prosthesis using a continuum whiffle tree mechanism: a case study. IEEE Trans Neural Syst Rehabil Eng. 2018;26(3):609\u201318.","journal-title":"IEEE Trans Neural Syst Rehabil Eng"},{"issue":"4","key":"1259_CR15","doi-asserted-by":"crossref","first-page":"828","DOI":"10.1109\/TNSRE.2014.2301234","volume":"22","author":"C Cipriani","year":"2014","unstructured":"Cipriani C, Segil JL, Birdwell JA, Weir RF. Dexterous control of a prosthetic hand using fine-wire intramuscular electrodes in targeted extrinsic muscles. IEEE Trans Neural Syst Rehabil Eng. 2014;22(4):828\u201336.","journal-title":"IEEE Trans Neural Syst Rehabil Eng."},{"issue":"2","key":"1259_CR16","doi-asserted-by":"crossref","first-page":"125","DOI":"10.1023\/B:AURO.0000016863.48502.98","volume":"16","author":"MC Carrozza","year":"2004","unstructured":"Carrozza MC, Suppo C, Sebastiani F, Massa B, Vecchi F, Lazzarini R, et al. The SPRING hand: development of a self-adaptive prosthesis for restoring natural grasping. Auton Robot. 2004;16(2):125\u201341.","journal-title":"Auton Robot"},{"key":"1259_CR17","unstructured":"Carrozza MC, Dario P, Vecchi F, Roccella S, Zecca M, Sebastiani F, editors. The CyberHand: on the design of a cybernetic prosthetic hand intended to be interfaced to the peripheral nervous system. Proceedings 2003 IEEE\/RSJ International Conference on Intelligent Robots and Systems (IROS 2003) (Cat No 03CH37453); 2003: IEEE."},{"key":"1259_CR18","doi-asserted-by":"crossref","unstructured":"Alkhatib F, Mahdi E, Cabibihan J-J, editors. Design and analysis of flexible joints for a robust 3D printed prosthetic hand. 2019 IEEE 16th International Conference on Rehabilitation Robotics (ICORR); 2019: IEEE.","DOI":"10.1109\/ICORR.2019.8779372"},{"issue":"5","key":"1259_CR19","doi-asserted-by":"crossref","first-page":"599","DOI":"10.1682\/JRRD.2011.10.0188","volume":"50","author":"JT Belter","year":"2013","unstructured":"Belter JT, Segil JL, SM B. Mechanical design and performance specifications of anthropomorphic prosthetic hands: a review. J Rehabil Res Dev. 2013;50(5):599.","journal-title":"J Rehabil Res Dev."},{"issue":"1","key":"1259_CR20","doi-asserted-by":"crossref","first-page":"11","DOI":"10.3390\/prosthesis3010003","volume":"3","author":"KH Ng","year":"2021","unstructured":"Ng KH, Nazari V, Alam M. Can prosthetic hands mimic a Healthy human hand? Prosthesis. 2021;3(1):11\u201323.","journal-title":"Prosthesis"},{"issue":"7","key":"1259_CR21","doi-asserted-by":"crossref","first-page":"1137","DOI":"10.1016\/j.apmr.2016.01.031","volume":"97","author":"SG Postema","year":"2016","unstructured":"Postema SG, Bongers RM, Brouwers MA, Burger H, Norling-Hermansson LM, Reneman MF, et al. Musculoskeletal complaints in transverse upper limb reduction deficiency and amputation in the Netherlands: prevalence, predictors, and effect on health. Arch Phys Med Rehabil. 2016;97(7):1137\u201345.","journal-title":"Arch Phys Med Rehabil"},{"issue":"9","key":"1259_CR22","doi-asserted-by":"crossref","first-page":"742","DOI":"10.1097\/PHM.0b013e3181b306ec","volume":"88","author":"MA Hanley","year":"2009","unstructured":"Hanley MA, Ehde DM, Jensen M, Czerniecki J, Smith DG, Robinson LR. Chronic pain associated with upper-limb loss. Am J Phys Med Rehabil Assoc Acad Physiatrists. 2009;88(9):742.","journal-title":"Am J Phys Med Rehabil Assoc Acad Physiatrists"},{"issue":"4","key":"1259_CR23","doi-asserted-by":"crossref","first-page":"497","DOI":"10.1177\/0309364615584658","volume":"40","author":"H Burger","year":"2016","unstructured":"Burger H, Vidmar G. A survey of overuse problems in patients with acquired or congenital upper limb deficiency. Prosthet Orthot Int. 2016;40(4):497\u2013502.","journal-title":"Prosthet Orthot Int"},{"issue":"17","key":"1259_CR24","doi-asserted-by":"crossref","first-page":"1317","DOI":"10.1080\/09638280701320763","volume":"29","author":"H Burger","year":"2007","unstructured":"Burger H, Maver T, Marin\u010dek \u010c. Partial hand amputation and work. Disabil Rehabil. 2007;29(17):1317\u201321.","journal-title":"Disabil Rehabil"},{"issue":"10","key":"1259_CR25","doi-asserted-by":"crossref","first-page":"1146","DOI":"10.1080\/09638288.2017.1289418","volume":"40","author":"SE Bouma","year":"2018","unstructured":"Bouma SE, Postema SG, Bongers RM, Dijkstra PU, van der Sluis CK. Musculoskeletal complaints in individuals with finger or partial hand amputations in the Netherlands: a cross-sectional study. Disabil Rehabil. 2018;40(10):1146\u201353.","journal-title":"Disabil Rehabil"},{"key":"1259_CR26","unstructured":"Neumann DA. Kinesiology of the musculoskeletal system-e-book: foundations for rehabilitation. Elsevier Health Sciences; 2016."},{"issue":"1","key":"1259_CR27","doi-asserted-by":"crossref","first-page":"2","DOI":"10.1016\/j.hansur.2016.09.012","volume":"36","author":"M Soubeyrand","year":"2017","unstructured":"Soubeyrand M, Assabah B, B\u00e9gin M, Laemmel E, Dos Santos A, Cr\u00e9z\u00e9 M. Pronation and supination of the hand: anatomy and biomechanics. Hand Surg Rehabil. 2017;36(1):2\u201311.","journal-title":"Hand Surg Rehabil"},{"issue":"4","key":"1259_CR28","doi-asserted-by":"crossref","first-page":"600","DOI":"10.1109\/TNSRE.2015.2398112","volume":"23","author":"F Montagnani","year":"2015","unstructured":"Montagnani F, Controzzi M, Cipriani C. Is it finger or wrist dexterity that is missing in current hand prostheses? IEEE Trans Neural Syst Rehabil Eng. 2015;23(4):600\u20139.","journal-title":"IEEE Trans Neural Syst Rehabil Eng"},{"key":"1259_CR29","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/1743-0003-11-132","volume":"11","author":"MJ Major","year":"2014","unstructured":"Major MJ, Stine RL, Heckathorne CW, Fatone S, Gard SA. Comparison of range-of-motion and variability in upper body movements between transradial prosthesis users and able-bodied controls when executing goal-oriented tasks. J Neuroeng Rehabil. 2014;11:1\u201310.","journal-title":"J Neuroeng Rehabil"},{"issue":"6","key":"1259_CR30","doi-asserted-by":"crossref","first-page":"609","DOI":"10.1682\/JRRD.2010.07.0137","volume":"45","author":"PJ Kyberd","year":"2011","unstructured":"Kyberd PJ, Lemaire ED, Scheme E, MacPhail C, Goudreau L, Bush G, et al. Two-degree-of-freedom powered prosthetic wrist. J Rehabil Res Dev. 2011; 45(6):609\u201317.","journal-title":"J Rehabil Res Dev."},{"issue":"1","key":"1259_CR31","doi-asserted-by":"crossref","first-page":"261","DOI":"10.1109\/TRO.2018.2865890","volume":"35","author":"NM Bajaj","year":"2019","unstructured":"Bajaj NM, Spiers AJ, Dollar AM. State of the art in artificial wrists: a review of prosthetic and robotic wrist design. IEEE Trans Robot. 2019;35(1):261\u201377.","journal-title":"IEEE Trans Robot."},{"issue":"4","key":"1259_CR32","doi-asserted-by":"crossref","first-page":"764","DOI":"10.1002\/ar.24911","volume":"306","author":"A Demofonti","year":"2023","unstructured":"Demofonti A, Carpino G, Tagliamonte NL, Baldini G, Bramato L, Zollo L. Design of a modular and compliant wrist module for upper limb prosthetics. Anat Rec. 2023;306(4):764\u201376.","journal-title":"Anat Rec."},{"key":"1259_CR33","doi-asserted-by":"crossref","unstructured":"Bajaj NM, Spiers AJ, Dollar AM. State of the art in prosthetic wrists: commercial and research devices. 2015 IEEE International Conference on Rehabilitation Robotics (ICORR). IEEE; 2015. pp. 331\u2013338.","DOI":"10.1109\/ICORR.2015.7281221"},{"key":"1259_CR34","doi-asserted-by":"crossref","unstructured":"Cappello L, D'Accolti D, Gherardini M, Controzzi M, Cipriani C. A 2-degree-of-freedom quasi-passive prosthetic wrist with two levels of compliance. IEEE Robot Autom Lett. 2022.","DOI":"10.1109\/LRA.2022.3208692"},{"issue":"2","key":"1259_CR35","doi-asserted-by":"crossref","first-page":"502","DOI":"10.1109\/TMRB.2022.3155279","volume":"4","author":"R Damerla","year":"2022","unstructured":"Damerla R, Rice K, Rubio-Ejchel D, Miro M, Braucher E, Foote J, et al. Design and testing of a novel, high-performance two DoF prosthetic wrist. IEEE Trans Med Robot Bionics. 2022;4(2):502\u201319.","journal-title":"IEEE Trans Med Robot Bionics"},{"issue":"3","key":"1259_CR36","doi-asserted-by":"crossref","first-page":"300","DOI":"10.1080\/17483107.2016.1253117","volume":"12","author":"J Ten Kate","year":"2017","unstructured":"Ten Kate J, Smit G, Breedveld P. 3D-printed upper limb prostheses: a review. Disabil Rehabil Assist Technol. 2017;12(3):300\u201314.","journal-title":"Disabil Rehabil Assist Technol"},{"key":"1259_CR37","doi-asserted-by":"crossref","unstructured":"Uellendahl J, Uellendahl E. Experience fitting partial hand prostheses with externally powered fingers. Grasping the future: advances in powered upper limb prosthetics. 2012:15\u201327.","DOI":"10.2174\/978160805439811201010015"},{"issue":"6","key":"1259_CR38","doi-asserted-by":"crossref","first-page":"1264","DOI":"10.1109\/TNSRE.2018.2829183","volume":"26","author":"I Imbinto","year":"2018","unstructured":"Imbinto I, Montagnani F, Bacchereti M, Cipriani C, Davalli A, Sacchetti R, et al. The S-Finger: a synergetic externally powered digit with tactile sensing and feedback. IEEE Trans Neural Syst Rehabil Eng. 2018;26(6):1264\u201371.","journal-title":"IEEE Trans Neural Syst Rehabil Eng"},{"key":"1259_CR39","doi-asserted-by":"crossref","first-page":"32","DOI":"10.1109\/RBME.2016.2523799","volume":"9","author":"I Imbinto","year":"2016","unstructured":"Imbinto I, Peccia C, Controzzi M, Cutti AG, Davalli A, Sacchetti R, et al. Treatment of the partial hand amputation: an engineering perspective. IEEE Rev Biomed Eng. 2016;9:32\u201348.","journal-title":"IEEE Rev Biomed Eng"},{"key":"1259_CR40","doi-asserted-by":"crossref","unstructured":"Jeong G-C, Kim Y, Choi W, Gu G, Lee H-J, Hong MB, et al., editors. On the design of a novel underactuated robotic finger prosthesis for partial hand amputation. 2019 IEEE 16th International Conference on Rehabilitation Robotics (ICORR); 2019: IEEE.","DOI":"10.1109\/ICORR.2019.8779553"},{"issue":"1","key":"1259_CR41","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/s12984-016-0130-0","volume":"13","author":"M Deijs","year":"2016","unstructured":"Deijs M, Bongers R, Ringeling-van Leusen N, Van Der Sluis C. Flexible and static wrist units in upper limb prosthesis users: functionality scores, user satisfaction and compensatory movements. J Neuroeng Rehabil. 2016;13(1):1\u201313.","journal-title":"J Neuroeng Rehabil"},{"issue":"1","key":"1259_CR42","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/s12984-021-00855-x","volume":"18","author":"HE Williams","year":"2021","unstructured":"Williams HE, Chapman CS, Pilarski PM, Vette AH, Hebert JS. Myoelectric prosthesis users and non-disabled individuals wearing a simulated prosthesis exhibit similar compensatory movement strategies. J Neuroeng Rehabil. 2021;18(1):1\u201315.","journal-title":"J Neuroeng Rehabil"},{"issue":"57","key":"1259_CR43","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s12984-018-0396-5","volume":"15","author":"I Batzianoulis","year":"2018","unstructured":"Batzianoulis I, Krausz NE, Simon AM, Hargrove L, Billard A. Decoding the grasping intention from electromyography during reaching motions. J Neuroeng Rehabil. 2018;15(57):1-13. https:\/\/doi.org\/10.1186\/s12984-018-0396-5","journal-title":"J Neuroeng Rehabil"},{"issue":"1","key":"1259_CR44","doi-asserted-by":"crossref","first-page":"47","DOI":"10.1177\/1545968318817825","volume":"33","author":"MM Ardestani","year":"2019","unstructured":"Ardestani MM, Kinnaird CR, Henderson CE, Hornby TG. Compensation or recovery? Altered kinetics and neuromuscular synergies following high-intensity stepping training poststroke. Neurorehabil Neural Repair. 2019;33(1):47\u201358.","journal-title":"Neurorehabil Neural Repair"},{"issue":"1","key":"1259_CR45","doi-asserted-by":"crossref","first-page":"72","DOI":"10.1016\/j.gaitpost.2010.03.011","volume":"32","author":"EE Butler","year":"2010","unstructured":"Butler EE, Ladd AL, Louie SA, LaMont LE, Wong W, Rose J. Three-dimensional kinematics of the upper limb during a reach and grasp cycle for children. Gait Posture. 2010;32(1):72\u20137.","journal-title":"Gait Posture"},{"issue":"6","key":"1259_CR46","doi-asserted-by":"crossref","DOI":"10.1371\/journal.pone.0199549","volume":"13","author":"AM Valevicius","year":"2018","unstructured":"Valevicius AM, et al. Characterization of normative hand movements during two functional upper limb tasks. PLoS ONE. 2018;13(6): e0199549.","journal-title":"PLoS ONE"},{"key":"1259_CR47","unstructured":"Bernstein N. The co-ordination and regulation of movements. The co-ordination and regulation of movements. 1966."},{"issue":"3","key":"1259_CR48","doi-asserted-by":"crossref","first-page":"300","DOI":"10.1038\/nn1010","volume":"6","author":"A d'Avella","year":"2003","unstructured":"d\u2019Avella A, Saltiel P, Bizzi E. Combinations of muscle synergies in the construction of a natural motor behavior. Nat Neurosci. 2003;6(3):300\u20138.","journal-title":"Nat Neurosci"},{"issue":"11","key":"1259_CR49","doi-asserted-by":"crossref","first-page":"2029","DOI":"10.1016\/j.apmr.2012.03.011","volume":"93","author":"AJ Metzger","year":"2012","unstructured":"Metzger AJ, Dromerick AW, Holley RJ, Lum PS. Characterization of compensatory trunk movements during prosthetic upper limb reaching tasks. Arch Phys Med Rehabil. 2012;93(11):2029\u201334.","journal-title":"Arch Phys Med Rehabil"},{"issue":"9","key":"1259_CR50","doi-asserted-by":"crossref","first-page":"1128","DOI":"10.1016\/j.clinbiomech.2008.05.008","volume":"23","author":"SL Carey","year":"2008","unstructured":"Carey SL, Highsmith MJ, Maitland ME, Dubey RV. Compensatory movements of transradial prosthesis users during common tasks. Clin Biomech. 2008;23(9):1128\u201335.","journal-title":"Clin Biomech"},{"issue":"1","key":"1259_CR51","doi-asserted-by":"crossref","first-page":"34","DOI":"10.1016\/j.jht.2018.10.002","volume":"33","author":"KL Kontson","year":"2020","unstructured":"Kontson KL, Wang S, Barovsky S, Bloomer C, Wozniczka L, Civillico EF. Assessing kinematic variability during performance of Jebsen-Taylor hand function test. J Hand Ther. 2020;33(1):34\u201344.","journal-title":"J Hand Ther"},{"issue":"6755","key":"1259_CR52","doi-asserted-by":"crossref","first-page":"788","DOI":"10.1038\/44565","volume":"401","author":"DD Lee","year":"1999","unstructured":"Lee DD, Seung HS. Learning the parts of objects by non-negative matrix factorization. Nature. 1999;401(6755):788\u201391.","journal-title":"Nature"},{"issue":"2","key":"1259_CR53","doi-asserted-by":"crossref","first-page":"420","DOI":"10.1109\/TRO.2018.2880121","volume":"35","author":"MB Hong","year":"2018","unstructured":"Hong MB, Kim SJ, Ihn YS, Jeong G-C, Kim K. KULEX-hand: an underactuated wearable hand for grasping power assistance. IEEE Trans Robot. 2018;35(2):420\u201332.","journal-title":"IEEE Trans Robot"},{"issue":"7","key":"1259_CR54","doi-asserted-by":"crossref","first-page":"1086","DOI":"10.1016\/j.jhsa.2007.06.014","volume":"32","author":"WB Kleinman","year":"2007","unstructured":"Kleinman WB. Stability of the distal radioulna joint: biomechanics, pathophysiology, physical diagnosis, and restoration of function what we have learned in 25 years. J Hand Surg. 2007;32(7):1086\u2013106.","journal-title":"J Hand Surg"},{"key":"1259_CR55","unstructured":"Christensen S, Bai S, editors. A novel shoulder mechanism with a double parallelogram linkage for upper-body exoskeletons. Wearable robotics: challenges and trends: Proceedings of the 2nd International Symposium on Wearable Robotics, WeRob2016, October 18\u201321, 2016, Segovia, Spain; 2017: Springer."},{"issue":"2","key":"1259_CR56","doi-asserted-by":"crossref","first-page":"502","DOI":"10.1109\/TMRB.2022.3155279","volume":"4","author":"R Damerla","year":"2022","unstructured":"Damerla R, et al. Design and testing of a novel, high-performance two DoF prosthetic wrist. IEEE Trans Med Robot Bion. 2022;4(2):502\u201319.","journal-title":"IEEE Trans Med Robot Bion"},{"issue":"1","key":"1259_CR57","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/1743-0003-8-29","volume":"8","author":"C Cipriani","year":"2011","unstructured":"Cipriani C, Controzzi M, Carrozza MC. The SmartHand transradial prosthesis. J Neuroeng Rehabil. 2011;8(1):1\u201314.","journal-title":"J Neuroeng Rehabil"},{"key":"1259_CR58","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/s12984-020-00774-3","volume":"18","author":"J-H Park","year":"2021","unstructured":"Park J-H, Shin J-H, Lee H, Roh J, Park H-S. Alterations in intermuscular coordination underlying isokinetic exercise after a stroke and their implications on neurorehabilitation. J Neuroeng Rehabil. 2021;18:1\u201317.","journal-title":"J Neuroeng Rehabil"},{"issue":"4","key":"1259_CR59","doi-asserted-by":"crossref","first-page":"1009","DOI":"10.1007\/s00421-021-04604-9","volume":"121","author":"NA Turpin","year":"2021","unstructured":"Turpin NA, Uriac S, Dalleau G. How to improve the muscle synergy analysis methodology? Eur J Appl Physiol. 2021;121(4):1009\u201325.","journal-title":"Eur J Appl Physiol"},{"issue":"4","key":"1259_CR60","doi-asserted-by":"crossref","first-page":"882","DOI":"10.1109\/TNSRE.2018.2810859","volume":"26","author":"P Kieliba","year":"2018","unstructured":"Kieliba P, et al. How are muscle synergies affected by electromyography pre-processing? IEEE Trans Neural Syst Rehabil Eng. 2018;26(4):882\u201393.","journal-title":"IEEE Trans Neural Syst Rehabil Eng"},{"key":"1259_CR61","doi-asserted-by":"crossref","unstructured":"Gopura RARC, Kiguchi K. Electromyography (EMG)-signal based fuzzy-neuro control of a 3 degrees of freedom (3DOF) exoskeleton robot for human upper-limb motion assist. J Natl Sci Foundation Sri Lanka. 2009; 37(4)-pronator, supinator.","DOI":"10.4038\/jnsfsr.v37i4.1470"},{"key":"1259_CR62","unstructured":"Kim T et al. Electromyographic analysis: theory and application, HANMI Medical Publishing Co. 2013."},{"key":"1259_CR63","unstructured":"Freriks B, Hermens HJ. SENIAM 9: European recommendations for surface electromyography, ISBN: 90-75452-14-4 (CD-rom), Roessingh Research and Development bv. 1999."},{"issue":"5","key":"1259_CR64","doi-asserted-by":"crossref","first-page":"361","DOI":"10.1016\/S1050-6411(00)00027-4","volume":"10","author":"HJ Hermens","year":"2000","unstructured":"Hermens HJ, Freriks B, Disselhorst-Klug C, Rau G. Development of recommendations for SEMG sensors and sensor placement procedures. J Electromyogr Kinesiol. 2000;10(5):361\u201374.","journal-title":"J Electromyogr Kinesiol"},{"issue":"5","key":"1259_CR65","doi-asserted-by":"crossref","first-page":"361","DOI":"10.1016\/S1050-6411(00)00027-4","volume":"10","author":"HJ Hermens","year":"2000","unstructured":"Hermens HJ, et al. Development of recommendations for SEMG sensors and sensor placement procedures. J Electromyogr Kinesiol. 2000;10(5):361\u201374.","journal-title":"J Electromyogr Kinesiol"},{"key":"1259_CR66","doi-asserted-by":"crossref","unstructured":"Robertson DGE, Caldwell GE, Hamill J, Kamen G, Whittlesey S. Research methods in biomechanics. Human kinetics; 2013.","DOI":"10.5040\/9781492595809"},{"key":"1259_CR67","unstructured":"https:\/\/docs.vicon.com\/display\/Nexus212\/Upper+body+modeling+with+Plug-in+Gait."},{"issue":"3","key":"1259_CR68","volume":"2","author":"C Bloomer","year":"2020","unstructured":"Bloomer C, Kontson KL. Comparison of DEKA Arm and body-powered upper limb prosthesis joint kinematics. Arch Rehabil Res Clin Transl. 2020;2(3): 100057.","journal-title":"Arch Rehabil Res Clin Transl."},{"issue":"18","key":"1259_CR69","doi-asserted-by":"crossref","first-page":"5104","DOI":"10.3390\/s20185104","volume":"20","author":"JA Albert","year":"2020","unstructured":"Albert JA, et al. Evaluation of the pose tracking performance of the azure kinect and kinect v2 for gait analysis in comparison with a gold standard: a pilot study. Sensors. 2020;20(18):5104.","journal-title":"Sensors"},{"key":"1259_CR70","first-page":"311","volume":"50","author":"RH Jebsen","year":"1969","unstructured":"Jebsen RH. An objective and standardized test of hand function. Arch Phys Med Rehabil. 1969;50:311\u20139.","journal-title":"Arch Phys Med Rehabil"},{"issue":"3","key":"1259_CR71","doi-asserted-by":"crossref","first-page":"768","DOI":"10.1152\/jn.00670.2012","volume":"109","author":"J Roh","year":"2013","unstructured":"Roh J, Rymer WZ, Perreault EJ, Yoo SB, Beer RF. Alterations in upper limb muscle synergy structure in chronic stroke survivors. J Neurophysiol. 2013;109(3):768\u201381.","journal-title":"J Neurophysiol"},{"issue":"5","key":"1259_CR72","doi-asserted-by":"crossref","DOI":"10.1088\/1741-2560\/11\/5\/051001","volume":"11","author":"M Ison","year":"2014","unstructured":"Ison M, Artemiadis P. The role of muscle synergies in myoelectric control: trends and challenges for simultaneous multifunction control. J Neural Eng. 2014;11(5): 051001.","journal-title":"J Neural Eng"},{"issue":"31","key":"1259_CR73","doi-asserted-by":"crossref","first-page":"eaaw6339","DOI":"10.1126\/scirobotics.aaw6339","volume":"4","author":"A Furui","year":"2019","unstructured":"Furui A, Eto S, Nakagaki K, Shimada K, Nakamura G, Masuda A, et al. A myoelectric prosthetic hand with muscle synergy-based motion determination and impedance model-based biomimetic control. Sci Robot. 2019;4(31):eaaw6339.","journal-title":"Sci Robot"},{"key":"1259_CR74","doi-asserted-by":"crossref","first-page":"420","DOI":"10.1109\/TNSRE.2022.3151055","volume":"30","author":"Y Gloumakov","year":"2022","unstructured":"Gloumakov Y, Bimbo J, Dollar AM. Trajectory control\u2014an effective strategy for controlling multi-DOF upper limb prosthetic devices. IEEE Trans Neural Syst Rehabil Eng. 2022;30:420\u201330.","journal-title":"IEEE Trans Neural Syst Rehabil Eng"},{"key":"1259_CR75","doi-asserted-by":"crossref","unstructured":"Spiers AJ, Gloumakov Y, Dollar AM, editors. Examining the impact of wrist mobility on reaching motion compensation across a discretely sampled workspace. 2018 7th IEEE International Conference on Biomedical Robotics and Biomechatronics (Biorob); 2018: IEEE.","DOI":"10.1109\/BIOROB.2018.8487871"},{"key":"1259_CR76","volume-title":"Motor learning and control","author":"R Magill","year":"2010","unstructured":"Magill R, Anderson DI. Motor learning and control. New York: McGraw-Hill Publishing; 2010."},{"issue":"3","key":"1259_CR77","doi-asserted-by":"crossref","first-page":"126","DOI":"10.1097\/JPO.0b013e31817ecb16","volume":"20","author":"CR Gambrell","year":"2008","unstructured":"Gambrell CR. Overuse syndrome and the unilateral upper limb amputee: consequences and prevention. JPO J Prosthet Orthot. 2008;20(3):126\u201332.","journal-title":"JPO J Prosthet Orthot."},{"issue":"1","key":"1259_CR78","doi-asserted-by":"crossref","first-page":"14546","DOI":"10.1038\/s41598-022-18624-8","volume":"12","author":"Y Matsuura","year":"2022","unstructured":"Matsuura Y, Matsunaga N, Akuzawa H, Kojima T, Oshikawa T, Iizuka S, et al. Difference in muscle synergies of the butterfly technique with and without swimmer\u2019s shoulder. Sci Rep. 2022;12(1):14546.","journal-title":"Sci Rep"},{"issue":"6","key":"1259_CR79","doi-asserted-by":"crossref","first-page":"3084","DOI":"10.1152\/jn.00960.2009","volume":"103","author":"G Torres-Oviedo","year":"2010","unstructured":"Torres-Oviedo G, Ting LH. Subject-specific muscle synergies in human balance control are consistent across different biomechanical contexts. J Neurophysiol. 2010;103(6):3084\u201398.","journal-title":"J Neurophysiol"},{"key":"1259_CR80","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/s12984-018-0454-z","volume":"16","author":"TA Valk","year":"2019","unstructured":"Valk TA, et al. Fixed muscle synergies and their potential to improve the intuitive control of myoelectric assistive technology for upper extremities. J Neuroeng Rehabil. 2019;16:1\u201320.","journal-title":"J Neuroeng Rehabil"}],"container-title":["Journal of NeuroEngineering and Rehabilitation"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12984-023-01259-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12984-023-01259-9\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12984-023-01259-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,11,18]],"date-time":"2023-11-18T14:26:25Z","timestamp":1700317585000},"score":1,"resource":{"primary":{"URL":"https:\/\/jneuroengrehab.biomedcentral.com\/articles\/10.1186\/s12984-023-01259-9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,10,5]]},"references-count":80,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2023,12]]}},"alternative-id":["1259"],"URL":"https:\/\/doi.org\/10.1186\/s12984-023-01259-9","relation":{"has-preprint":[{"id-type":"doi","id":"10.21203\/rs.3.rs-3010650\/v1","asserted-by":"object"}]},"ISSN":["1743-0003"],"issn-type":[{"value":"1743-0003","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,10,5]]},"assertion":[{"value":"1 June 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"21 September 2023","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"5 October 2023","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The healthy subjects and an amputee person signed an informed consent approved by the Pohang University of Science and Technology IRB prior to the experiment (No. PIRB-2022-E012).","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they have no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"135"}}