{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,4]],"date-time":"2026-11-04T07:58:20Z","timestamp":1793779100349,"version":"4.6.1"},"reference-count":101,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2024,4,15]],"date-time":"2024-04-15T00:00:00Z","timestamp":1713139200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2024,4,15]],"date-time":"2024-04-15T00:00:00Z","timestamp":1713139200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J NeuroEngineering Rehabil"],"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>Incorporating instrument measurements into clinical assessments can improve the accuracy of results when assessing mobility related to activities of daily living. This can assist clinicians in making evidence-based decisions. In this context, kinematic measures are considered essential for the assessment of sensorimotor recovery after stroke. The aim of this study was to assess the validity of using an Android device to evaluate kinematic data during the performance of a standardized mobility test in people with chronic stroke and hemiparesis.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>This is a cross-sectional study including 36 individuals with chronic stroke and hemiparesis and 33 age-matched healthy subjects. A simple smartphone attached to the lumbar spine with an elastic band was used to measure participants\u2019 kinematics during a standardized mobility test by using the inertial sensor embedded in it. This test includes postural control, walking, turning and sitting down, and standing up. Differences between stroke and non-stroke participants in the kinematic parameters obtained after data sensor processing were studied, as well as in the total execution and reaction times. Also, the relationship between the kinematic parameters and the community ambulation ability, degree of disability and functional mobility of individuals with stroke was studied.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>Compared to controls, participants with chronic stroke showed a larger medial-lateral displacement (<jats:italic>p<\/jats:italic>\u2009=\u20090.022) in bipedal stance, a higher medial-lateral range (<jats:italic>p<\/jats:italic>\u2009&lt;\u20090.001) and a lower cranio-caudal range (<jats:italic>p<\/jats:italic>\u2009=\u20090.024) when walking, and lower turn-to-sit power (<jats:italic>p<\/jats:italic>\u2009=\u20090.001), turn-to-sit jerk (<jats:italic>p<\/jats:italic>\u2009=\u20090.026) and sit-to-stand jerk (<jats:italic>p<\/jats:italic>\u2009=\u20090.001) when assessing turn-to-sit-to-stand. Medial-lateral range and total execution time significantly correlated with all the clinical tests (<jats:italic>p<\/jats:italic>\u2009&lt;\u20090.005), and resulted significantly different between independent and limited community ambulation patients (<jats:italic>p<\/jats:italic>\u2009=\u20090.042 and <jats:italic>p<\/jats:italic>\u2009=\u20090.006, respectively) as well as stroke participants with significant disability or slight\/moderate disability (<jats:italic>p<\/jats:italic>\u2009=\u20090.024 and <jats:italic>p<\/jats:italic>\u2009=\u20090.041, respectively).<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusion<\/jats:title>\n                <jats:p>This study reports a valid, single, quick and easy-to-use test for assessing kinematic parameters in chronic stroke survivors by using a standardized mobility test with a smartphone. This measurement could provide valid clinical information on reaction time and kinematic parameters of postural control and gait, which can help in planning better intervention approaches.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s12984-024-01346-5","type":"journal-article","created":{"date-parts":[[2024,4,15]],"date-time":"2024-04-15T03:26:48Z","timestamp":1713151608000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":6,"title":["Validity of an android device for assessing mobility in people with chronic stroke and hemiparesis: a cross-sectional study"],"prefix":"10.1186","volume":"21","author":[{"given":"M. Luz","family":"S\u00e1nchez-S\u00e1nchez","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Maria-Arantzazu","family":"Ruescas-Nicolau","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anna","family":"Arnal-G\u00f3mez","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marco","family":"Iosa","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sof\u00eda","family":"P\u00e9rez-Alenda","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sara","family":"Cort\u00e9s-Amador","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2024,4,15]]},"reference":[{"key":"1346_CR1","doi-asserted-by":"publisher","first-page":"795","DOI":"10.1016\/S1474-4422(21)00252-0","volume":"20","author":"VL Feigin","year":"2021","unstructured":"Feigin VL, Stark BA, Johnson CO, Roth GA, Bisignano C, Abady GG, et al. Global, regional, and national burden of stroke and its risk factors, 1990\u20132019: a systematic analysis for the global burden of Disease Study 2019. Lancet Neurol. 2021;20:795\u2013820.","journal-title":"Lancet Neurol"},{"key":"1346_CR2","doi-asserted-by":"publisher","first-page":"e235","DOI":"10.1016\/S2214-109X(20)30520-9","volume":"9","author":"F Lanas","year":"2021","unstructured":"Lanas F, Seron P. Facing the stroke burden worldwide. Lancet Glob Health. 2021;9:e235\u20136.","journal-title":"Lancet Glob Health"},{"key":"1346_CR3","doi-asserted-by":"publisher","first-page":"e021510","DOI":"10.1136\/bmjopen-2018-021510","volume":"8","author":"A Mansfield","year":"2018","unstructured":"Mansfield A, Aqui A, Danells CJ, Knorr S, Centen A, DePaul VG, et al. Does perturbation-based balance training prevent falls among individuals with chronic stroke? A randomised controlled trial. BMJ Open. 2018;8:e021510.","journal-title":"BMJ Open"},{"key":"1346_CR4","doi-asserted-by":"publisher","first-page":"141","DOI":"10.1016\/j.apmr.2019.09.003","volume":"101","author":"N Kang","year":"2020","unstructured":"Kang N, Lee RD, Lee JH, Hwang MH. Functional balance and postural control improvements in patients with stroke after noninvasive brain stimulation: a Meta-analysis. Arch Phys Med Rehabil. 2020;101:141\u201353.","journal-title":"Arch Phys Med Rehabil"},{"key":"1346_CR5","doi-asserted-by":"crossref","unstructured":"Lin Q, Zheng Y, Lian P, Guo Y, Huang H, Luo Z et al. Quantitative Static and Dynamic Assessment of Balance Control in Stroke patients. J Vis Exp. 2020;:60884.","DOI":"10.3791\/60884"},{"key":"1346_CR6","doi-asserted-by":"publisher","first-page":"555","DOI":"10.1080\/10749357.2017.1366011","volume":"24","author":"EMGDS Silva","year":"2017","unstructured":"Silva EMGDS, Ribeiro TS, Da Silva TCC, Costa MFP, Cavalcanti FADC, Lindquist ARR. Effects of constraint-induced movement therapy for lower limbs on measurements of functional mobility and postural balance in subjects with stroke: a randomized controlled trial. Top Stroke Rehabil. 2017;24:555\u201361.","journal-title":"Top Stroke Rehabil"},{"key":"1346_CR7","doi-asserted-by":"publisher","first-page":"e17317","DOI":"10.1097\/MD.0000000000017317","volume":"98","author":"GV De Paula","year":"2019","unstructured":"De Paula GV, Da Silva TR, De Souza JT, Luvizutto GJ, Bazan SGZ, Modolo GP, et al. Effect of ankle-foot orthosis on functional mobility and dynamic balance of patients after stroke: study protocol for a randomized controlled clinical trial. Med (Baltim). 2019;98:e17317.","journal-title":"Med (Baltim)"},{"key":"1346_CR8","doi-asserted-by":"publisher","first-page":"197","DOI":"10.1310\/tsr2103-197","volume":"21","author":"TB Hafsteinsd\u00f3ttir","year":"2014","unstructured":"Hafsteinsd\u00f3ttir TB, Rensink M, Schuurmans M. Clinimetric properties of the timed up and go test for patients with stroke: a systematic review. Top Stroke Rehabil. 2014;21:197\u2013210.","journal-title":"Top Stroke Rehabil"},{"key":"1346_CR9","doi-asserted-by":"publisher","first-page":"37","DOI":"10.2340\/16501977-2280","volume":"50","author":"DR Louie","year":"2018","unstructured":"Louie DR, Eng JJ. Berg Balance Scale score at admission can predict walking suitable for community ambulation at discharge from inpatient stroke rehabilitation. J Rehabil Med. 2018;50:37\u201344.","journal-title":"J Rehabil Med"},{"key":"1346_CR10","doi-asserted-by":"publisher","first-page":"84","DOI":"10.1186\/s12984-022-01062-y","volume":"19","author":"J Veldema","year":"2022","unstructured":"Veldema J, Gharabaghi A. Non-invasive brain stimulation for improving gait, balance, and lower limbs motor function in stroke. J Neuroeng Rehabil. 2022;19:84.","journal-title":"J Neuroeng Rehabil"},{"key":"1346_CR11","doi-asserted-by":"publisher","first-page":"495","DOI":"10.3390\/healthcare10030495","volume":"10","author":"JS Tedla","year":"2022","unstructured":"Tedla JS, Gular K, Reddy RS, De S\u00e1 Ferreira A, Rodrigues EC, Kakaraparthi VN, et al. Effectiveness of Constraint-Induced Movement Therapy (CIMT) on balance and functional mobility in the Stroke Population: a systematic review and Meta-analysis. Healthcare. 2022;10:495.","journal-title":"Healthcare"},{"issue":"Supplement 1","key":"1346_CR12","doi-asserted-by":"publisher","first-page":"7710393050","DOI":"10.5014\/ajot.2023.77S10005","volume":"77","author":"D Geller","year":"2023","unstructured":"Geller D, Goldberg C, Winterbottom L, Nilsen DM, Mahoney D, Gillen G. Task oriented training interventions for adults with stroke to improve ADL and functional mobility performance (2012\u20132019). Am J Occup Ther. 2023;77(Supplement 1):7710393050.","journal-title":"Am J Occup Ther"},{"key":"1346_CR13","doi-asserted-by":"publisher","first-page":"472","DOI":"10.3390\/healthcare9040472","volume":"9","author":"N-K Hwang","year":"2021","unstructured":"Hwang N-K, Park J-S, Chang M-Y. Telehealth interventions to Support Self-Management in Stroke survivors: a systematic review. Healthcare. 2021;9:472.","journal-title":"Healthcare"},{"key":"1346_CR14","doi-asserted-by":"publisher","first-page":"310","DOI":"10.1007\/978-3-319-58877-3_40","volume-title":"Wireless Mobile Communication and Healthcare","author":"S Negrini","year":"2017","unstructured":"Negrini S, Serpelloni M, Amici C, Gobbo M, Silvestro C, Buraschi R, et al. Use of Wearable Inertial Sensor in the Assessment of Timed-Up-and-Go test: influence of device Placement on temporal variable estimation. In: Perego P, Andreoni G, Rizzo G, editors. Wireless Mobile Communication and Healthcare. Cham: Springer International Publishing; 2017. pp. 310\u20137."},{"key":"1346_CR15","doi-asserted-by":"publisher","first-page":"141","DOI":"10.1186\/s12883-018-1146-9","volume":"18","author":"AH Alghadir","year":"2018","unstructured":"Alghadir AH, Al-Eisa ES, Anwer S, Sarkar B. Reliability, validity, and responsiveness of three scales for measuring balance in patients with chronic stroke. BMC Neurol. 2018;18:141.","journal-title":"BMC Neurol"},{"key":"1346_CR16","doi-asserted-by":"publisher","first-page":"432","DOI":"10.1177\/0269215513504942","volume":"28","author":"F Tripp","year":"2014","unstructured":"Tripp F, Krakow K. Effects of an aquatic therapy approach (Halliwick-Therapy) on functional mobility in subacute stroke patients: a randomized controlled trial. Clin Rehabil. 2014;28:432\u20139.","journal-title":"Clin Rehabil"},{"key":"1346_CR17","doi-asserted-by":"publisher","first-page":"101449","DOI":"10.1016\/j.rehab.2020.10.003","volume":"64","author":"E Embrechts","year":"2021","unstructured":"Embrechts E, Van Criekinge T, Schr\u00f6der J, Nijboer T, Lafosse C, Truijen S, et al. The association between visuospatial neglect and balance and mobility post-stroke onset: a systematic review. Ann Phys Rehabil Med. 2021;64:101449.","journal-title":"Ann Phys Rehabil Med"},{"key":"1346_CR18","doi-asserted-by":"publisher","first-page":"10948","DOI":"10.3390\/ijerph191710948","volume":"19","author":"A Mallo-L\u00f3pez","year":"2022","unstructured":"Mallo-L\u00f3pez A, Fern\u00e1ndez-Gonz\u00e1lez P, S\u00e1nchez-Herrera-Baeza P, Cuesta-G\u00f3mez A, Molina-Rueda F, Aguilera-Rubio \u00c1. The Use of Portable devices for the Instrumental Assessment of Balance in patients with chronic stroke: a systematic review. Int J Environ Res Public Health. 2022;19:10948.","journal-title":"Int J Environ Res Public Health"},{"key":"1346_CR19","doi-asserted-by":"publisher","first-page":"451","DOI":"10.1177\/1747493017711813","volume":"12","author":"G Kwakkel","year":"2017","unstructured":"Kwakkel G, Lannin NA, Borschmann K, English C, Ali M, Churilov L, et al. Standardized measurement of sensorimotor recovery in stroke trials: Consensus-based core recommendations from the Stroke Recovery and Rehabilitation Roundtable. Int J Stroke. 2017;12:451\u201361.","journal-title":"Int J Stroke"},{"key":"1346_CR20","doi-asserted-by":"publisher","first-page":"88","DOI":"10.3390\/s20010088","volume":"20","author":"Y-R Hou","year":"2019","unstructured":"Hou Y-R, Chiu Y-L, Chiang S-L, Chen H-Y, Sung W-H. Development of a smartphone-based Balance Assessment System for subjects with stroke. Sensors. 2019;20:88.","journal-title":"Sensors"},{"key":"1346_CR21","doi-asserted-by":"publisher","first-page":"177","DOI":"10.1080\/17483107.2022.2072527","volume":"19","author":"J Peters","year":"2024","unstructured":"Peters J, Abou L, Wong E, Dossou MS, Sosnoff JJ, Rice LA. Smartphone-based gait and balance assessment in survivors of stroke: a systematic review. Disabil Rehabil Assist Technol. 2024;19:177\u201387.","journal-title":"Disabil Rehabil Assist Technol"},{"key":"1346_CR22","doi-asserted-by":"publisher","first-page":"18901","DOI":"10.3390\/s150818901","volume":"15","author":"M Del Rosario","year":"2015","unstructured":"Del Rosario M, Redmond S, Lovell N. Tracking the evolution of Smartphone Sensing for Monitoring Human Movement. Sensors. 2015;15:18901\u201333.","journal-title":"Sensors"},{"key":"1346_CR23","doi-asserted-by":"publisher","first-page":"3555","DOI":"10.1016\/j.jstrokecerebrovasdis.2018.08.012","volume":"27","author":"JA Merch\u00e1n-Baeza","year":"2018","unstructured":"Merch\u00e1n-Baeza JA, Gonz\u00e1lez-S\u00e1nchez M, Cuesta-Vargas AI. Using smartphones to collect quantitative data on lower limb functionality in people who have suffered a stroke. J Stroke Cerebrovasc Dis. 2018;27:3555\u201362.","journal-title":"J Stroke Cerebrovasc Dis"},{"key":"1346_CR24","doi-asserted-by":"publisher","first-page":"3243","DOI":"10.1080\/09638288.2019.1585972","volume":"42","author":"NCJ Lin","year":"2020","unstructured":"Lin NCJ, Hayward KS, D\u2019Cruz K, Thompson E, Li X, Lannin NA. Validity and reliability of a smartphone inclinometer app for measuring passive upper limb range of motion in a stroke population. Disabil Rehabil. 2020;42:3243\u20139.","journal-title":"Disabil Rehabil"},{"key":"1346_CR25","doi-asserted-by":"publisher","first-page":"223","DOI":"10.1080\/10400435.2019.1611676","volume":"33","author":"JA Moral-Mu\u00f1oz","year":"2021","unstructured":"Moral-Mu\u00f1oz JA, Zhang W, Cobo MJ, Herrera-Viedma E, Kaber DB. Smartphone-based systems for physical rehabilitation applications: a systematic review. Assist Technol. 2021;33:223\u201336.","journal-title":"Assist Technol"},{"key":"1346_CR26","doi-asserted-by":"publisher","first-page":"461","DOI":"10.1016\/j.jbmt.2019.01.011","volume":"23","author":"JC Polese","year":"2019","unstructured":"Polese JC, Faria E, Ribeiro-Samora GS, Lima GA, Coelho de Morais Faria LP, Scianni CD. Google fit smartphone application or Gt3X actigraph: which is better for detecting the stepping activity of individuals with stroke? A validity study. J Bodyw Mov Ther. 2019;23:461\u20135.","journal-title":"J Bodyw Mov Ther"},{"key":"1346_CR27","doi-asserted-by":"publisher","first-page":"394","DOI":"10.1177\/0269215519895796","volume":"34","author":"PHV Costa","year":"2020","unstructured":"Costa PHV, de Jesus TPD, Winstein C, Torriani-Pasin C, Polese JC. An investigation into the validity and reliability of mHealth devices for counting steps in chronic stroke survivors. Clin Rehabil. 2020;34:394\u2013403.","journal-title":"Clin Rehabil"},{"key":"1346_CR28","doi-asserted-by":"publisher","first-page":"5","DOI":"10.1186\/s12984-016-0114-0","volume":"13","author":"NA Capela","year":"2016","unstructured":"Capela NA, Lemaire ED, Baddour N, Rudolf M, Goljar N, Burger H. Evaluation of a smartphone human activity recognition application with able-bodied and stroke participants. J Neuroeng Rehabil. 2016;13:5.","journal-title":"J Neuroeng Rehabil"},{"key":"1346_CR29","doi-asserted-by":"publisher","first-page":"191","DOI":"10.1016\/j.cmpb.2018.04.027","volume":"161","author":"Y-R Hou","year":"2018","unstructured":"Hou Y-R, Chiu Y-L, Chiang S-L, Chen H-Y, Sung W-H. Feasibility of a smartphone-based balance assessment system for subjects with chronic stroke. Comput Methods Programs Biomed. 2018;161:191\u20135.","journal-title":"Comput Methods Programs Biomed"},{"key":"1346_CR30","doi-asserted-by":"publisher","first-page":"1305","DOI":"10.1016\/j.jstrokecerebrovasdis.2015.02.004","volume":"24","author":"T Isho","year":"2015","unstructured":"Isho T, Tashiro H, Usuda S. Accelerometry-based gait characteristics evaluated using a smartphone and their association with fall risk in people with chronic stroke. J Stroke Cerebrovasc Dis off J Natl Stroke Assoc. 2015;24:1305\u201311.","journal-title":"J Stroke Cerebrovasc Dis off J Natl Stroke Assoc"},{"key":"1346_CR31","doi-asserted-by":"crossref","unstructured":"How T-V, Chee J, Wan E, Mihailidis A, MyWalk:. A Mobile App for Gait Asymmetry Rehabilitation in the Community. In: Proceedings of the ICTs for improving Patients Rehabilitation Research Techniques. Venice, Italy: IEEE; 2013.","DOI":"10.4108\/icst.pervasivehealth.2013.252118"},{"key":"1346_CR32","doi-asserted-by":"publisher","first-page":"1234","DOI":"10.1016\/j.apmr.2004.11.016","volume":"86","author":"E Viosca","year":"2005","unstructured":"Viosca E, Mart\u00ednez JL, Almagro PL, Gracia A, Gonz\u00e1lez C. Proposal and validation of a New Functional Ambulation classification scale for clinical use. Arch Phys Med Rehabil. 2005;86:1234\u20138.","journal-title":"Arch Phys Med Rehabil"},{"key":"1346_CR33","doi-asserted-by":"publisher","first-page":"281","DOI":"10.1016\/j.jphys.2022.05.017","volume":"68","author":"H Haggag","year":"2022","unstructured":"Haggag H, Hodgson C, Clinimetrics. Modified Rankin Scale (mRS). J Physiother. 2022;68:281.","journal-title":"J Physiother"},{"key":"1346_CR34","doi-asserted-by":"publisher","first-page":"590","DOI":"10.1136\/jnnp.2005.079145","volume":"77","author":"A-C Jonsson","year":"2006","unstructured":"Jonsson A-C. Prevalence and intensity of pain after stroke: a population based study focusing on patients\u2019 perspectives. J Neurol Neurosurg Psychiatry. 2006;77:590\u20135.","journal-title":"J Neurol Neurosurg Psychiatry"},{"key":"1346_CR35","unstructured":"S\u00e1nchez-S\u00e1nchez ML, Ruescas-Nicolau M-A, Arnal-G\u00f3mez A, P\u00e9rez-Alenda S, Miralles-Albalat A, Safont-Arnau D et al. An android device to assess functional tasks related to the risk of falling in people with chronic stroke. Int J Stroke. 2023;18 3_suppl:257\u20138."},{"key":"1346_CR36","doi-asserted-by":"publisher","first-page":"1495","DOI":"10.1016\/j.ijsu.2014.07.013","volume":"12","author":"E von Elm","year":"2014","unstructured":"von Elm E, Altman DG, Egger M, Pocock SJ, G\u00f8tzsche PC, Vandenbroucke JP. The strengthening the reporting of Observational studies in Epidemiology (STROBE) Statement: guidelines for reporting observational studies. Int J Surg. 2014;12:1495\u20139.","journal-title":"Int J Surg"},{"key":"1346_CR37","doi-asserted-by":"publisher","first-page":"25","DOI":"10.1093\/ptj\/82.1.25","volume":"82","author":"M Blackburn","year":"2002","unstructured":"Blackburn M, Van Vliet P, Mockett SP. Reliability of measurements obtained with the Modified Ashworth Scale in the Lower extremities of people with stroke. Phys Ther. 2002;82:25\u201334.","journal-title":"Phys Ther"},{"key":"1346_CR38","doi-asserted-by":"publisher","first-page":"705","DOI":"10.1007\/s10072-018-3254-0","volume":"39","author":"D Shi","year":"2018","unstructured":"Shi D, Chen X, Li Z. Diagnostic test accuracy of the Montreal Cognitive Assessment in the detection of post-stroke cognitive impairment under different stages and cutoffs: a systematic review and meta-analysis. Neurol Sci. 2018;39:705\u201316.","journal-title":"Neurol Sci"},{"key":"1346_CR39","doi-asserted-by":"publisher","first-page":"142","DOI":"10.1111\/j.1532-5415.1991.tb01616.x","volume":"39","author":"D Podsiadlo","year":"1991","unstructured":"Podsiadlo D, Richardson S. The timed up & go: a test of Basic Functional mobility for Frail Elderly persons. J Am Geriatr Soc. 1991;39:142\u20138.","journal-title":"J Am Geriatr Soc"},{"key":"1346_CR40","doi-asserted-by":"publisher","first-page":"e0165663","DOI":"10.1371\/journal.pone.0165663","volume":"11","author":"K Lyders Johansen","year":"2016","unstructured":"Lyders Johansen K, Derby Stistrup R, Skibdal Schj\u00f8tt C, Madsen J, Vinther A. Absolute and relative reliability of the timed \u2018Up & go\u2019 test and \u201830second chair-stand\u2019 test in Hospitalised patients with stroke. PLoS ONE. 2016;11:e0165663.","journal-title":"PLoS ONE"},{"key":"1346_CR41","doi-asserted-by":"publisher","first-page":"413","DOI":"10.3233\/NRE-210026","volume":"48","author":"DK-Y Cheng","year":"2021","unstructured":"Cheng DK-Y, Dagenais M, Alsbury-Nealy K, Legasto JM, Scodras S, Aravind G, et al. Distance-limited walk tests post-stroke: a systematic review of measurement properties1. NeuroRehabilitation. 2021;48:413\u201339.","journal-title":"NeuroRehabilitation"},{"key":"1346_CR42","doi-asserted-by":"publisher","first-page":"35","DOI":"10.1016\/j.gaitpost.2020.03.005","volume":"78","author":"BF Mentiplay","year":"2020","unstructured":"Mentiplay BF, Clark RA, Bower KJ, Williams G, Pua Y-H. Five times sit-to-stand following stroke: relationship with strength and balance. Gait Posture. 2020;78:35\u20139.","journal-title":"Gait Posture"},{"key":"1346_CR43","doi-asserted-by":"publisher","first-page":"407","DOI":"10.1016\/j.apmr.2009.10.030","volume":"91","author":"Y Mong","year":"2010","unstructured":"Mong Y, Teo TW, Ng SS. 5-repetition sit-to-stand test in subjects with chronic stroke: reliability and validity. Arch Phys Med Rehabil. 2010;91:407\u201313.","journal-title":"Arch Phys Med Rehabil"},{"key":"1346_CR44","doi-asserted-by":"publisher","first-page":"171073","DOI":"10.1109\/ACCESS.2019.2956239","volume":"7","author":"W Yan","year":"2019","unstructured":"Yan W, Bastos L, Magalhaes A. Performance Assessment of the Android Smartphone\u2019s IMU in a GNSS\/INS coupled Navigation Model. IEEE Access. 2019;7:171073\u201383.","journal-title":"IEEE Access"},{"key":"1346_CR45","doi-asserted-by":"publisher","first-page":"23168","DOI":"10.3390\/s150923168","volume":"15","author":"Q Mourcou","year":"2015","unstructured":"Mourcou Q, Fleury A, Franco C, Klopcic F, Vuillerme N. Performance Evaluation of Smartphone Inertial Sensors Measurement for Range of Motion. Sensors. 2015;15:23168\u201387.","journal-title":"Sensors"},{"key":"1346_CR46","doi-asserted-by":"publisher","first-page":"18270","DOI":"10.3390\/s150818270","volume":"15","author":"A Ruiz-Zafra","year":"2015","unstructured":"Ruiz-Zafra A, Orantes-Gonz\u00e1lez E, Noguera M, Benghazi K, Heredia-Jimenez J. A comparative study on the suitability of smartphones and IMU for Mobile, Unsupervised Energy Expenditure Calculi. Sensors. 2015;15:18270\u201386.","journal-title":"Sensors"},{"key":"1346_CR47","doi-asserted-by":"publisher","first-page":"872","DOI":"10.3390\/s23020872","volume":"23","author":"P Fran\u010dek","year":"2023","unstructured":"Fran\u010dek P, Jambro\u0161i\u0107 K, Horvat M, Planinec V. The performance of Inertial Measurement Unit sensors on various hardware platforms for Binaural Head-Tracking Applications. Sensors. 2023;23:872.","journal-title":"Sensors"},{"key":"1346_CR48","unstructured":"Pedrero-S\u00e1nchez JF. Desarrollo De Procedimientos De Valoraci\u00f3n Funcional Mediante Sensores Portables. Universidad Polit\u00e9cnica de Valencia; 2023."},{"key":"1346_CR49","first-page":"1","volume":"64","author":"E Medina Ripoll","year":"2017","unstructured":"Medina Ripoll E, Pedrero S\u00e1nchez JF, Garrido Jaen JD, Lopez Pascual J, Bermejo Bosch I, Pitarch Corresa S, et al. FallSkip: Valoraci\u00f3n Del riesgo de ca\u00eddas en personas mayores. Rev Biomec\u00e1nica. 2017;64:1\u20135.","journal-title":"Rev Biomec\u00e1nica"},{"key":"1346_CR50","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.gaitpost.2007.10.010","volume":"28","author":"JJ Kavanagh","year":"2008","unstructured":"Kavanagh JJ, Menz HB. Accelerometry: a technique for quantifying movement patterns during walking. Gait Posture. 2008;28:1\u201315.","journal-title":"Gait Posture"},{"key":"1346_CR51","doi-asserted-by":"publisher","first-page":"60","DOI":"10.1016\/j.gaitpost.2009.02.017","volume":"30","author":"C Mizuike","year":"2009","unstructured":"Mizuike C, Ohgi S, Morita S. Analysis of stroke patient walking dynamics using a tri-axial accelerometer. Gait Posture. 2009;30:60\u20134.","journal-title":"Gait Posture"},{"key":"1346_CR52","doi-asserted-by":"publisher","first-page":"635","DOI":"10.1007\/s40846-016-0178-0","volume":"36","author":"M Iosa","year":"2016","unstructured":"Iosa M, Bini F, Marinozzi F, Fusco A, Morone G, Koch G, et al. Stability and Harmony of Gait in patients with Subacute Stroke. J Med Biol Eng. 2016;36:635\u201343.","journal-title":"J Med Biol Eng"},{"key":"1346_CR53","doi-asserted-by":"publisher","first-page":"7","DOI":"10.23736\/S1973-9087.16.04203-9","volume":"53","author":"M Tramontano","year":"2017","unstructured":"Tramontano M, Morone G, Curcio A, Temperoni G, Medici A, Morelli D, et al. Maintaining gait stability during dual walking task: effects of age and neurological disorders. Eur J Phys Rehabil Med. 2017;53:7\u201313.","journal-title":"Eur J Phys Rehabil Med"},{"key":"1346_CR54","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1155\/2012\/187965","volume":"2012","author":"M Iosa","year":"2012","unstructured":"Iosa M, Morone G, Fusco A, Pratesi L, Bragoni M, Coiro P, et al. Effects of walking endurance reduction on Gait Stability in patients with stroke. Stroke Res Treat. 2012;2012:1\u20136.","journal-title":"Stroke Res Treat"},{"key":"1346_CR55","doi-asserted-by":"publisher","first-page":"439","DOI":"10.1682\/JRRD.2011.03.0057","volume":"49","author":"M Iosa","year":"2012","unstructured":"Iosa M, Fusco A, Morone G, Pratesi L, Coiro P, Venturiero V, et al. Assessment of upper-body dynamic stability during walking in patients with subacute stroke. J Rehabil Res Dev. 2012;49:439.","journal-title":"J Rehabil Res Dev"},{"key":"1346_CR56","doi-asserted-by":"publisher","first-page":"79","DOI":"10.1080\/17434440.2021.1988849","volume":"18","author":"P Picerno","year":"2021","unstructured":"Picerno P, Iosa M, D\u2019Souza C, Benedetti MG, Paolucci S, Morone G. Wearable inertial sensors for human movement analysis: a five-year update. Expert Rev Med Devices. 2021;18:79\u201394.","journal-title":"Expert Rev Med Devices"},{"key":"1346_CR57","doi-asserted-by":"publisher","first-page":"e30135","DOI":"10.2196\/30135","volume":"23","author":"Y-C Hsu","year":"2021","unstructured":"Hsu Y-C, Wang H, Zhao Y, Chen F, Tsui K-L. Automatic Recognition and Analysis of Balance Activity in Community-Dwelling older adults: Algorithm Validation. J Med Internet Res. 2021;23:e30135.","journal-title":"J Med Internet Res"},{"key":"1346_CR58","doi-asserted-by":"publisher","first-page":"6567","DOI":"10.3390\/s23146567","volume":"23","author":"J-F Pedrero-S\u00e1nchez","year":"2023","unstructured":"Pedrero-S\u00e1nchez J-F, De-Rosario-Mart\u00ednez H, Medina-Ripoll E, Garrido-Ja\u00e9n D, Serra-A\u00f1\u00f3 P, Moll\u00e0-Casanova S, et al. The reliability and accuracy of a fall risk Assessment Procedure using Mobile Smartphone Sensors compared with a physiological Profile Assessment. Sensors. 2023;23:6567.","journal-title":"Sensors"},{"key":"1346_CR59","doi-asserted-by":"publisher","first-page":"103617","DOI":"10.1016\/j.bspc.2022.103617","volume":"75","author":"JF Pedrero-S\u00e1nchez","year":"2022","unstructured":"Pedrero-S\u00e1nchez JF, Belda-Lois J-M, Serra-A\u00f1\u00f3 P, Ingl\u00e9s M, L\u00f3pez-Pascual J. Classification of healthy, Alzheimer and Parkinson populations with a multi-branch neural network. Biomed Signal Process Control. 2022;75:103617.","journal-title":"Biomed Signal Process Control"},{"key":"1346_CR60","doi-asserted-by":"publisher","first-page":"39","DOI":"10.1007\/s00421-004-1041-5","volume":"92","author":"W Zijlstra","year":"2004","unstructured":"Zijlstra W. Assessment of spatio-temporal parameters during unconstrained walking. Eur J Appl Physiol. 2004;92:39\u201344.","journal-title":"Eur J Appl Physiol"},{"key":"1346_CR61","doi-asserted-by":"publisher","first-page":"292","DOI":"10.1089\/tmj.2011.0132","volume":"18","author":"S Nishiguchi","year":"2012","unstructured":"Nishiguchi S, Yamada M, Nagai K, Mori S, Kajiwara Y, Sonoda T, et al. Reliability and validity of Gait Analysis by Android-Based Smartphone. Telemed E-Health. 2012;18:292\u20136.","journal-title":"Telemed E-Health"},{"key":"1346_CR62","doi-asserted-by":"publisher","first-page":"103","DOI":"10.1186\/s12984-019-0576-y","volume":"16","author":"P Serra-A\u00f1\u00f3","year":"2019","unstructured":"Serra-A\u00f1\u00f3 P, Pedrero-S\u00e1nchez JF, Hurtado-Abell\u00e1n J, Ingl\u00e9s M, Esp\u00ed-L\u00f3pez GV, L\u00f3pez-Pascual J. Mobility assessment in people with Alzheimer disease using smartphone sensors. J Neuroeng Rehabil. 2019;16:103.","journal-title":"J Neuroeng Rehabil"},{"key":"1346_CR63","first-page":"227","volume-title":"Using the fft-ddi method to measure displacements with piezoelectric, resistive and Icp accelerometers","author":"JGT Ribeiro","year":"2003","unstructured":"Ribeiro JGT, Castro JTPD, Freire JLF. Using the fft-ddi method to measure displacements with piezoelectric, resistive and Icp accelerometers. Kissimmee (Florida): Society for Experimental Mechanics; 2003. pp. 227\u201333."},{"key":"1346_CR64","doi-asserted-by":"publisher","first-page":"1578","DOI":"10.1016\/j.jbiomech.2009.03.049","volume":"42","author":"P Esser","year":"2009","unstructured":"Esser P, Dawes H, Collett J, Howells K. IMU: Inertial sensing of vertical CoM movement. J Biomech. 2009;42:1578\u201381.","journal-title":"J Biomech"},{"key":"1346_CR65","doi-asserted-by":"publisher","first-page":"612","DOI":"10.1049\/el:20060124","volume":"42","author":"J Favre","year":"2006","unstructured":"Favre J, Jolles BM, Siegrist O, Aminian K. Quaternion-based fusion of gyroscopes and accelerometers to improve 3D angle measurement. Electron Lett. 2006;42:612.","journal-title":"Electron Lett"},{"key":"1346_CR66","doi-asserted-by":"publisher","first-page":"466","DOI":"10.1007\/s00421-003-0837-z","volume":"89","author":"U Lindemann","year":"2003","unstructured":"Lindemann U, Claus H, Stuber M, Augat P, Muche R, Nikolaus T, et al. Measuring power during the sit-to-stand transfer. Eur J Appl Physiol. 2003;89:466\u201370.","journal-title":"Eur J Appl Physiol"},{"key":"1346_CR67","doi-asserted-by":"publisher","first-page":"1074","DOI":"10.1016\/j.clinbiomech.2007.07.013","volume":"22","author":"M Iosa","year":"2007","unstructured":"Iosa M, Mazz\u00e0 C, Frusciante R, Zok M, Aprile I, Ricci E, et al. Mobility assessment of patients with facioscapulohumeral dystrophy. Clin Biomech. 2007;22:1074\u201382.","journal-title":"Clin Biomech"},{"key":"1346_CR68","first-page":"109","volume":"37","author":"JC Wall","year":"2000","unstructured":"Wall JC, Bell C, Campbell S, Davis J. The timed get-up-and-Go test revisited: measurement of the component tasks. J Rehabil Res Dev. 2000;37:109\u201313.","journal-title":"J Rehabil Res Dev"},{"key":"1346_CR69","doi-asserted-by":"publisher","first-page":"119","DOI":"10.1016\/j.medengphy.2009.10.015","volume":"32","author":"A Weiss","year":"2010","unstructured":"Weiss A, Herman T, Plotnik M, Brozgol M, Maidan I, Giladi N, et al. Can an accelerometer enhance the utility of the timed up & go test when evaluating patients with Parkinson\u2019s disease? Med Eng Phys. 2010;32:119\u201325.","journal-title":"Med Eng Phys"},{"key":"1346_CR70","doi-asserted-by":"publisher","first-page":"956","DOI":"10.1109\/10.532130","volume":"43","author":"TE Prieto","year":"1996","unstructured":"Prieto TE, Myklebust JB, Hoffmann RG, Lovett EG, Myklebust BM. Measures of postural steadiness: differences between healthy young and elderly adults. IEEE Trans Biomed Eng. 1996;43:956\u201366.","journal-title":"IEEE Trans Biomed Eng"},{"key":"1346_CR71","doi-asserted-by":"publisher","first-page":"136","DOI":"10.1016\/j.apmr.2008.07.014","volume":"90","author":"KE Gordon","year":"2009","unstructured":"Gordon KE, Ferris DP, Kuo AD. Metabolic and Mechanical Energy Costs of Reducing Vertical Center of Mass Movement during Gait. Arch Phys Med Rehabil. 2009;90:136\u201344.","journal-title":"Arch Phys Med Rehabil"},{"key":"1346_CR72","doi-asserted-by":"publisher","first-page":"737","DOI":"10.1016\/S0268-0033(03)00139-6","volume":"18","author":"ME Hahn","year":"2003","unstructured":"Hahn ME, Chou L-S. Can motion of individual body segments identify dynamic instability in the elderly? Clin Biomech. 2003;18:737\u201344.","journal-title":"Clin Biomech"},{"key":"1346_CR73","doi-asserted-by":"publisher","first-page":"479","DOI":"10.1136\/jnnp.69.4.479","volume":"69","author":"P Haggard","year":"2000","unstructured":"Haggard P. Interference between gait and cognitive tasks in a rehabilitating neurological population. J Neurol Neurosurg Psychiatry. 2000;69:479\u201386.","journal-title":"J Neurol Neurosurg Psychiatry"},{"key":"1346_CR74","doi-asserted-by":"publisher","first-page":"igz036","DOI":"10.1093\/geroni\/igz036","volume":"3","author":"CR Brydges","year":"2019","unstructured":"Brydges CR. Effect size guidelines, sample size calculations, and statistical power in Gerontology. Innov Aging. 2019;3:igz036.","journal-title":"Innov Aging"},{"key":"1346_CR75","doi-asserted-by":"publisher","first-page":"1763","DOI":"10.1213\/ANE.0000000000002864","volume":"126","author":"P Schober","year":"2018","unstructured":"Schober P, Boer C, Schwarte LA. Correlation coefficients: appropriate use and interpretation. Anesth Analg. 2018;126:1763\u20138.","journal-title":"Anesth Analg"},{"key":"1346_CR76","doi-asserted-by":"publisher","first-page":"43","DOI":"10.1097\/00001648-199001000-00010","volume":"1","author":"KJ Rothman","year":"1990","unstructured":"Rothman KJ. No adjustments are needed for multiple comparisons. Epidemiol Camb Mass. 1990;1:43\u20136.","journal-title":"Epidemiol Camb Mass"},{"key":"1346_CR77","doi-asserted-by":"crossref","unstructured":"Portnoy S, Reif S, Mendelboim T, Rand D. Postural control of individuals with chronic stroke compared to healthy participants: Timed-Up-and-Go, functional Reach Test and center of pressure movement. Eur J Phys Rehabil Med. 2017;53.","DOI":"10.23736\/S1973-9087.17.04522-1"},{"key":"1346_CR78","doi-asserted-by":"publisher","first-page":"71","DOI":"10.1186\/s12984-022-01052-0","volume":"19","author":"H-W Liang","year":"2022","unstructured":"Liang H-W, Tai T-L, Li Y-H, Chen Y-C. Application of a virtual reality tracker-based system to measure seated postural stability in stroke patients. J Neuroeng Rehabil. 2022;19:71.","journal-title":"J Neuroeng Rehabil"},{"key":"1346_CR79","doi-asserted-by":"publisher","first-page":"95","DOI":"10.1186\/1743-0003-10-95","volume":"10","author":"Z Sawacha","year":"2013","unstructured":"Sawacha Z, Carraro E, Contessa P, Guiotto A, Masiero S, Cobelli C. Relationship between clinical and instrumental balance assessments in chronic post-stroke hemiparesis subjects. J Neuroeng Rehabil. 2013;10:95.","journal-title":"J Neuroeng Rehabil"},{"key":"1346_CR80","doi-asserted-by":"publisher","first-page":"58","DOI":"10.1016\/j.gaitpost.2018.07.182","volume":"66","author":"TC Boumer","year":"2018","unstructured":"Boumer TC, Martello SK, Devetak GF, Iucksch DD, Scrok ND, Manffra EF. Influence of feet position on COP measures in post-stroke patients in quiet standing. Gait Posture. 2018;66:58\u201362.","journal-title":"Gait Posture"},{"key":"1346_CR81","doi-asserted-by":"crossref","first-page":"886","DOI":"10.1016\/j.apmr.2003.05.012","volume":"85","author":"M De Haart","year":"2004","unstructured":"De Haart M, Geurts AC, Huidekoper SC, Fasotti L, Van Limbeek J. Recovery of standing balance in postacute stroke patients: a rehabilitation cohort study. Arch Phys Med Rehabil. 2004;85:886\u201395.","journal-title":"Arch Phys Med Rehabil"},{"key":"1346_CR82","doi-asserted-by":"publisher","first-page":"154","DOI":"10.1016\/j.gaitpost.2019.06.006","volume":"72","author":"GF Devetak","year":"2019","unstructured":"Devetak GF, Bohrer RCD, Rodacki ALF, Manffra EF. Center of mass in analysis of dynamic stability during gait following stroke: a systematic review. Gait Posture. 2019;72:154\u201366.","journal-title":"Gait Posture"},{"key":"1346_CR83","doi-asserted-by":"publisher","first-page":"140","DOI":"10.1186\/s12984-020-00768-1","volume":"17","author":"H-Y Hsiao","year":"2020","unstructured":"Hsiao H-Y, Gray VL, Borrelli J, Rogers MW. Biomechanical control of paretic lower limb during imposed weight transfer in individuals post-stroke. J Neuroeng Rehabil. 2020;17:140.","journal-title":"J Neuroeng Rehabil"},{"key":"1346_CR84","doi-asserted-by":"publisher","first-page":"1650","DOI":"10.1053\/apmr.2001.26256","volume":"82","author":"P-T Cheng","year":"2001","unstructured":"Cheng P-T, Wu S-H, Liaw M-Y, Wong AMK, Tang F-T. Symmetrical body-weight distribution training in stroke patients and its effect on fall prevention. Arch Phys Med Rehabil. 2001;82:1650\u20134.","journal-title":"Arch Phys Med Rehabil"},{"key":"1346_CR85","doi-asserted-by":"publisher","first-page":"349","DOI":"10.1179\/1074935714Z.0000000037","volume":"22","author":"AA Do Carmo","year":"2015","unstructured":"Do Carmo AA, Kleiner AFR, Barros RML. Alteration in the center of mass trajectory of patients after stroke. Top Stroke Rehabil. 2015;22:349\u201356.","journal-title":"Top Stroke Rehabil"},{"key":"1346_CR86","doi-asserted-by":"publisher","first-page":"1893","DOI":"10.3109\/09638288.2015.1107775","volume":"38","author":"Y Zhu","year":"2016","unstructured":"Zhu Y, Zhou C, Liu Y, Liu J, Jin J, Zhang S, et al. Effects of modified constraint-induced movement therapy on the lower extremities in patients with stroke: a pilot study. Disabil Rehabil. 2016;38:1893\u20139.","journal-title":"Disabil Rehabil"},{"key":"1346_CR87","doi-asserted-by":"publisher","first-page":"73","DOI":"10.3233\/NRE-141194","volume":"36","author":"C Bonnyaud","year":"2015","unstructured":"Bonnyaud C, Pradon D, Zory R, Bensmail D, Vuillerme N, Roche N. Gait parameters predicted by timed up and go performance in stroke patients. NeuroRehabilitation. 2015;36:73\u201380.","journal-title":"NeuroRehabilitation"},{"key":"1346_CR88","doi-asserted-by":"crossref","unstructured":"David V, Forjan M, Martinek J, Kotzian S, Jagos H, Rafolt D. Evaluating wearable multimodal sensor insoles for motion-pattern measurements in stroke rehabilitation \u2014 A pilot study. In: 2017 International Conference on Rehabilitation Robotics (ICORR). London: IEEE; 2017. p. 1543\u20138.","DOI":"10.1109\/ICORR.2017.8009467"},{"key":"1346_CR89","doi-asserted-by":"publisher","first-page":"156","DOI":"10.1186\/1475-925X-13-156","volume":"13","author":"A Gal\u00e1n-Mercant","year":"2014","unstructured":"Gal\u00e1n-Mercant A, Bar\u00f3n-L\u00f3pez FJ, Labajos-Manzanares MT, Cuesta-Vargas AI. Reliability and criterion-related validity with a smartphone used in timed-up-and-go test. Biomed Eng OnLine. 2014;13:156.","journal-title":"Biomed Eng OnLine"},{"key":"1346_CR90","doi-asserted-by":"publisher","first-page":"5744","DOI":"10.3390\/s20205744","volume":"20","author":"CE Lang","year":"2020","unstructured":"Lang CE, Barth J, Holleran CL, Konrad JD, Bland MD. Implementation of Wearable Sensing Technology for Movement: pushing Forward into the Routine Physical Rehabilitation Care Field. Sensors. 2020;20:5744.","journal-title":"Sensors"},{"key":"1346_CR91","doi-asserted-by":"publisher","first-page":"3426","DOI":"10.3390\/s23073426","volume":"23","author":"P Ortega-Bastidas","year":"2023","unstructured":"Ortega-Bastidas P, G\u00f3mez B, Aqueveque P, Luarte-Mart\u00ednez S, Cano-de-la-Cuerda R. Instrumented timed up and go test (iTUG)\u2014More than assessing time to Predict Falls: a systematic review. Sensors. 2023;23:3426.","journal-title":"Sensors"},{"key":"1346_CR92","doi-asserted-by":"publisher","first-page":"522","DOI":"10.1016\/j.apmr.2015.10.106","volume":"97","author":"S Dorsch","year":"2016","unstructured":"Dorsch S, Ada L, Canning CG. Lower limb strength is significantly impaired in all muscle groups in ambulatory people with chronic stroke: a cross-sectional study. Arch Phys Med Rehabil. 2016;97:522\u20137.","journal-title":"Arch Phys Med Rehabil"},{"key":"1346_CR93","doi-asserted-by":"publisher","first-page":"e0140317","DOI":"10.1371\/journal.pone.0140317","volume":"10","author":"C Bonnyaud","year":"2015","unstructured":"Bonnyaud C, Pradon D, Bensmail D, Roche N. Dynamic Stability and Risk of Tripping during the timed up and go test in Hemiparetic and healthy subjects. PLoS ONE. 2015;10:e0140317.","journal-title":"PLoS ONE"},{"key":"1346_CR94","doi-asserted-by":"publisher","first-page":"1732","DOI":"10.1053\/apmr.2002.36400","volume":"83","author":"LA Brown","year":"2002","unstructured":"Brown LA, Sleik RJ, Winder TR. Attentional demands for static postural control after stroke. Arch Phys Med Rehabil. 2002;83:1732\u20135.","journal-title":"Arch Phys Med Rehabil"},{"key":"1346_CR95","doi-asserted-by":"crossref","unstructured":"Abdollahi M, Kuber PM, Pierce M, Cristales K, Dombovy M, LaLonde J et al. Motor-Cognitive Dual-Task Paradigm Affects Timed Up & Go (TUG) Test Outcomes in Stroke Survivors. In: 2023 11th International IEEE\/EMBS Conference on Neural Engineering (NER). Baltimore, MD, USA: IEEE; 2023. p. 1\u20134.","DOI":"10.1109\/NER52421.2023.10123749"},{"key":"1346_CR96","volume-title":"Fisiolog\u00eda articular, dibujos comentados de mec\u00e1nica Humana. [Tronco Y Raquis]","author":"AI Kapandji","year":"2012","unstructured":"Kapandji AI. Fisiolog\u00eda articular, dibujos comentados de mec\u00e1nica Humana. [Tronco Y Raquis]. M\u00e9xico: Panamericana; 2012."},{"key":"1346_CR97","doi-asserted-by":"publisher","first-page":"133","DOI":"10.1115\/1.2834293","volume":"120","author":"M Saini","year":"1998","unstructured":"Saini M, Kerrigan DC, Thirunarayan MA, Duff-Raffaele M. The vertical displacement of the center of mass during walking: a comparison of four measurement methods. J Biomech Eng. 1998;120:133\u20139.","journal-title":"J Biomech Eng"},{"key":"1346_CR98","doi-asserted-by":"publisher","first-page":"3247","DOI":"10.3390\/s20113247","volume":"20","author":"A Zampogna","year":"2020","unstructured":"Zampogna A, Mileti I, Palermo E, Celletti C, Paoloni M, Manoni A, et al. Fifteen years of Wireless Sensors for Balance Assessment in Neurological disorders. Sensors. 2020;20:3247.","journal-title":"Sensors"},{"key":"1346_CR99","doi-asserted-by":"publisher","first-page":"385","DOI":"10.3390\/s22010385","volume":"22","author":"M Abdollahi","year":"2022","unstructured":"Abdollahi M, Kuber PM, Shiraishi M, Soangra R, Rashedi E. Kinematic analysis of 360\u00b0 turning in Stroke survivors using Wearable Motion Sensors. Sensors. 2022;22:385.","journal-title":"Sensors"},{"key":"1346_CR100","doi-asserted-by":"publisher","first-page":"599","DOI":"10.1682\/JRRD.2015.04.0065","volume":"53","author":"S W\u00fcest","year":"2016","unstructured":"W\u00fcest S, Mass\u00e9 F, Aminian K, Gonzenbach R, de Bruin ED. Reliability and validity of the inertial sensor-based timed up and go test in individuals affected by stroke. J Rehabil Res Dev. 2016;53:599\u2013610.","journal-title":"J Rehabil Res Dev"},{"key":"1346_CR101","doi-asserted-by":"publisher","first-page":"373","DOI":"10.1191\/026921599677595404","volume":"13","author":"AD Pandyan","year":"1999","unstructured":"Pandyan AD, Johnson GR, Price CIM, Curless RH, Barnes MP, Rodgers H. A review of the properties and limitations of the Ashworth and modified Ashworth Scales as measures of spasticity. Clin Rehabil. 1999;13:373\u201383.","journal-title":"Clin Rehabil"}],"container-title":["Journal of NeuroEngineering and Rehabilitation"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12984-024-01346-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12984-024-01346-5\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12984-024-01346-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,4,17]],"date-time":"2024-04-17T09:38:55Z","timestamp":1713346735000},"score":1,"resource":{"primary":{"URL":"https:\/\/jneuroengrehab.biomedcentral.com\/articles\/10.1186\/s12984-024-01346-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,4,15]]},"references-count":101,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2024,12]]}},"alternative-id":["1346"],"URL":"https:\/\/doi.org\/10.1186\/s12984-024-01346-5","relation":{},"ISSN":["1743-0003"],"issn-type":[{"value":"1743-0003","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,4,15]]},"assertion":[{"value":"3 August 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"22 March 2024","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"15 April 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The protocol for this study was approved by the Human Research Ethics Committee of the University of Valencia (Code H1417615024926). The procedures used in this study adhere to the tenets of the Declaration of Helsinki. Informed consent was obtained from all individual participants included in the study.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"54"}}