{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,29]],"date-time":"2026-10-29T18:38:05Z","timestamp":1793299085316,"version":"4.5.0"},"reference-count":57,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2024,8,8]],"date-time":"2024-08-08T00:00:00Z","timestamp":1723075200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2024,8,8]],"date-time":"2024-08-08T00:00:00Z","timestamp":1723075200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Orthotics and Prosthetics Outcomes Research Program","award":["W81XWH-16-1-0648"],"award-info":[{"award-number":["W81XWH-16-1-0648"]}]},{"name":"Orthotics and Prosthetics Outcomes Research Program","award":["W81XWH-16-1-0648"],"award-info":[{"award-number":["W81XWH-16-1-0648"]}]},{"name":"Orthotics and Prosthetics Outcomes Research Program","award":["W81XWH-16-1-0648"],"award-info":[{"award-number":["W81XWH-16-1-0648"]}]},{"name":"Orthotics and Prosthetics Outcomes Research Program","award":["W81XWH-16-1-0648"],"award-info":[{"award-number":["W81XWH-16-1-0648"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J NeuroEngineering Rehabil"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Patient access to body-powered and myoelectric upper limb prostheses in the United States is often restricted by a healthcare system that prioritizes prosthesis prescription based on cost and perceived value. Although this system operates on an underlying assumption that design differences between these prostheses leads to relative advantages and disadvantages of each device, there is limited empirical evidence to support this view.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Main text<\/jats:title>\n                    <jats:p>This commentary article will review a series of studies conducted by our research team with the goal of differentiating how prosthesis design might impact user performance on a variety of interrelated domains. Our central hypothesis is that the design and actuation method of body-powered and myoelectric prostheses might affect users\u2019 ability to access sensory feedback and account for device properties when planning movements. Accordingly, other domains that depend on these abilities may also be affected. While our work demonstrated some differences in availability of sensory feedback based on prosthesis design, this did not result in consistent differences in prosthesis embodiment, movement accuracy, movement quality, and overall kinematic patterns.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>Collectively, our findings suggest that performance may not necessarily depend on prosthesis design, allowing users to be successful with either device type depending on the circumstances. Prescription practices should rely more on individual needs and preferences than cost or prosthesis design. However, we acknowledge that there remains a dearth of evidence to inform decision-making and that an expanded research focus in this area will be beneficial.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s12984-024-01436-4","type":"journal-article","created":{"date-parts":[[2024,8,8]],"date-time":"2024-08-08T04:02:37Z","timestamp":1723089757000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":10,"title":["Perspectives on the comparative benefits of body-powered and myoelectric upper limb prostheses"],"prefix":"10.1186","volume":"21","author":[{"given":"Susannah M.","family":"Engdahl","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael A.","family":"Gonzalez","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christina","family":"Lee","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Deanna H.","family":"Gates","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2024,8,8]]},"reference":[{"key":"1436_CR1","doi-asserted-by":"crossref","unstructured":"Marinelli A, Boccardo N, Tessari F, Di Domenico D, Caserta G, Canepa M et al. Active upper limb prostheses: a review on current state and upcoming breakthroughs. Progress Biomedical Eng. 2022.","DOI":"10.1088\/2516-1091\/acac57"},{"key":"1436_CR2","doi-asserted-by":"crossref","unstructured":"Stevens PM, Highsmith MJ, Myoelectric, Power B. Design Options for Upper-Limb Prostheses: Introduction to the State of the Science Conference Proceedings. Journal of Prosthetics and Orthotics. 2017;29(4S).","DOI":"10.1097\/JPO.0000000000000150"},{"key":"1436_CR3","unstructured":"Anthem. Clinical UM, Guideline. Subject: Myoelectric Upper Extremity Prosthetic Devices. Guideline #: CG-OR-PR-05 [Internet]. 2023 [cited 2023 Apr 14]. https:\/\/www.anthem.com\/dam\/medpolicies\/abc\/active\/guidelines\/gl_pw_c169421.html"},{"key":"1436_CR4","unstructured":"Blue Cross Blue Shield of Massachusetts. Myoelectric Prosthetic and Orthotic Components for the Upper Limb. Policy Number: 227 [Internet]. 2022 [cited 2023 Apr 14]. https:\/\/www.bluecrossma.org\/medical-policies\/sites\/g\/files\/csphws2091\/files\/acquiadam-assets\/227%20Myoelectric%20Prosthetic%20and%20Components%20for%20the%20Upper%20Limb%20prn.pdf"},{"key":"1436_CR5","unstructured":"Florida Blue. Myoelectric Prosthetic and Orthotic Components for the Upper Limb [Internet]. 2022 [cited 2023 Apr 14]. https:\/\/mcgs.bcbsfl.com\/MCG?mcgId=09-L0000-07&pv=false"},{"key":"1436_CR6","unstructured":"United Healthcare. Prosthetic Devices, Specialized, Microprocessor or Myoelectric Limbs. Guideline Number: CS104.O [Internet]. 2022 [cited 2023 Apr 14]. https:\/\/www.uhcprovider.com\/content\/dam\/provider\/docs\/public\/policies\/medicaid-comm-plan\/prosthetic-devices-specialized-microprocessor-myoelectric-limbs-cs.pdf"},{"issue":"6","key":"1436_CR7","doi-asserted-by":"publisher","first-page":"535","DOI":"10.1001\/journalofethics.2015.17.6.stas1-1506","volume":"17","author":"CPF Pasquina","year":"2015","unstructured":"Pasquina CPF, Carvalho AJ, Sheehan TP. Ethics in rehabilitation: access to prosthetics and quality care following amputation. AMA J Ethics. 2015;17(6):535\u201346.","journal-title":"AMA J Ethics"},{"key":"1436_CR8","doi-asserted-by":"crossref","unstructured":"Biddiss E, McKeever P, Lindsay S, Chau T. Implications of prosthesis funding structures on the use of prostheses: experiences of individuals with upper limb absence. Prosthetics and Orthotics International [Internet]. 2011;35(2). https:\/\/journals.lww.com\/poijournal\/fulltext\/2011\/35020\/implications_of_prosthesis_funding_structures_on.11.aspx","DOI":"10.1177\/0309364611401776"},{"issue":"3","key":"1436_CR9","doi-asserted-by":"publisher","first-page":"247","DOI":"10.1682\/JRRD.2014.08.0192","volume":"52","author":"SL Carey","year":"2015","unstructured":"Carey SL, Lura DJ, Highsmith MJ. Differences in myoelectric and body-powered upper-limb prostheses: systematic literature review. J Rehabil Res Dev. 2015;52(3):247\u201362.","journal-title":"J Rehabil Res Dev"},{"issue":"4S","key":"1436_CR10","doi-asserted-by":"publisher","first-page":"P17","DOI":"10.1097\/JPO.0000000000000152","volume":"29","author":"SL Carey","year":"2017","unstructured":"Carey SL, Stevens PM, Highsmith MJ. Differences in Myoelectric and Body-Powered Upper-Limb prostheses: systematic literature review update 2013\u20132016. J Prosthetics Orthot. 2017;29(4S):P17\u201320.","journal-title":"J Prosthetics Orthot"},{"key":"1436_CR11","unstructured":"Management of Upper Extremity Amputation Rehabilitation Working Group. VA\/DoD Clinical Practice Guideline for the Management of Upper Extremity Amputation Rehabilitation [Internet]. 2022 [cited 2022 May 25]. https:\/\/www.healthquality.va.gov\/guidelines\/Rehab\/ULA\/VADoDULACPG_Final_508.pdf"},{"key":"1436_CR12","doi-asserted-by":"crossref","first-page":"205566832110652","DOI":"10.1177\/20556683211065262","volume":"8","author":"E O\u2019Brien","year":"2021","unstructured":"O\u2019Brien E, Stevens PM, Mandacina S, Jackman C. Prosthetic management of unilateral transradial amputation and limb deficiency: Consensus clinical standards of care. J Rehabilitation Assist Technol Eng. 2021;8:20556683211065262.","journal-title":"J Rehabilitation Assist Technol Eng"},{"key":"1436_CR13","doi-asserted-by":"publisher","first-page":"1905","DOI":"10.1109\/TNSRE.2021.3111741","volume":"29","author":"MA Gonzalez","year":"2021","unstructured":"Gonzalez MA, Lee C, Kang J, Gillespie RB, Gates DH. Getting a grip on the impact of Incidental Feedback from body-powered and myoelectric prostheses. IEEE Trans Neural Syst Rehabil Eng. 2021;29:1905\u201312.","journal-title":"IEEE Trans Neural Syst Rehabil Eng"},{"key":"1436_CR14","doi-asserted-by":"publisher","first-page":"105311","DOI":"10.1016\/j.clinbiomech.2021.105311","volume":"84","author":"SM Engdahl","year":"2021","unstructured":"Engdahl SM, Gates DH. Differences in quality of movements made with body-powered and myoelectric prostheses during activities of daily living. Clin Biomech Elsevier Ltd. 2021;84:105311.","journal-title":"Clin Biomech Elsevier Ltd"},{"key":"1436_CR15","doi-asserted-by":"publisher","first-page":"105713","DOI":"10.1016\/j.clinbiomech.2022.105713","volume":"97","author":"SM Engdahl","year":"2022","unstructured":"Engdahl SM, Lee C, Gates DH. A comparison of compensatory movements between body-powered and myoelectric prosthesis users during activities of daily living. Clin Biomech Elsevier Ltd. 2022;97:105713.","journal-title":"Clin Biomech Elsevier Ltd"},{"issue":"11","key":"1436_CR16","doi-asserted-by":"publisher","first-page":"3011","DOI":"10.1007\/s00221-022-06476-7","volume":"240","author":"C Lee","year":"2022","unstructured":"Lee C, Gonzalez MA, Kang J, Gates DH. Temporal and spatial goal-directed reaching in upper limb prosthesis users. Exp Brain Res. 2022;240(11):3011\u201321.","journal-title":"Exp Brain Res"},{"issue":"4\u20136","key":"1436_CR17","doi-asserted-by":"publisher","first-page":"293","DOI":"10.1007\/BF02363433","volume":"8","author":"DS Childress","year":"1980","unstructured":"Childress DS. Closed-loop control in prosthetic systems: historical perspective. Ann Biomed Eng. 1980;8(4\u20136):293\u2013303.","journal-title":"Ann Biomed Eng"},{"issue":"1","key":"1436_CR18","doi-asserted-by":"publisher","first-page":"155","DOI":"10.1186\/s12984-019-0622-9","volume":"16","author":"MA Wilke","year":"2019","unstructured":"Wilke MA, Niethammer C, Meyer B, Farina D, Dosen S. Psychometric characterization of incidental feedback sources during grasping with a hand prosthesis. J Neuroeng Rehabil. 2019;16(1):155.","journal-title":"J Neuroeng Rehabil"},{"issue":"1","key":"1436_CR19","doi-asserted-by":"publisher","first-page":"72","DOI":"10.1186\/1743-0003-11-72","volume":"11","author":"MM Sobuh","year":"2014","unstructured":"Sobuh MM, Kenney LP, Galpin AJ, Thies SB, McLaughlin J, Kulkarni J, et al. Visuomotor behaviours when using a myoelectric prosthesis. J Neuroeng Rehabil. 2014;11(1):72.","journal-title":"J Neuroeng Rehabil"},{"issue":"4","key":"1436_CR20","doi-asserted-by":"publisher","first-page":"416","DOI":"10.1080\/00222895.2017.1363703","volume":"50","author":"JVV Parr","year":"2018","unstructured":"Parr JVV, Vine SJ, Harrison NR, Wood G. Examining the Spatiotemporal disruption to Gaze when using a Myoelectric Prosthetic Hand. J Mot Behav. 2018;50(4):416\u201325.","journal-title":"J Mot Behav"},{"issue":"1","key":"1436_CR21","doi-asserted-by":"publisher","first-page":"37","DOI":"10.1186\/s12984-022-01006-6","volume":"19","author":"J Zbinden","year":"2022","unstructured":"Zbinden J, Lendaro E, Ortiz-Catalan M. Prosthetic embodiment: systematic review on definitions, measures, and experimental paradigms. J Neuroeng Rehabil. 2022;19(1):37.","journal-title":"J Neuroeng Rehabil"},{"issue":"1","key":"1436_CR22","doi-asserted-by":"publisher","first-page":"122","DOI":"10.1186\/s12984-022-01102-7","volume":"19","author":"J Zbinden","year":"2022","unstructured":"Zbinden J, Lendaro E, Ortiz-Catalan M. A multi-dimensional framework for prosthetic embodiment: a perspective for translational research. J Neuroeng Rehabil. 2022;19(1):122.","journal-title":"J Neuroeng Rehabil"},{"issue":"1","key":"1436_CR23","doi-asserted-by":"publisher","first-page":"143","DOI":"10.1016\/j.neubiorev.2007.07.001","volume":"32","author":"MJ Giummarra","year":"2008","unstructured":"Giummarra MJ, Gibson SJ, Georgiou-Karistianis N, Bradshaw JL. Mechanisms underlying embodiment, disembodiment and loss of embodiment. Neurosci Biobehavioral Reviews. 2008;32(1):143\u201360.","journal-title":"Neurosci Biobehavioral Reviews"},{"issue":"1","key":"1436_CR24","doi-asserted-by":"publisher","first-page":"15471","DOI":"10.1038\/s41598-020-72470-0","volume":"10","author":"SM Engdahl","year":"2020","unstructured":"Engdahl SM, Meehan SK, Gates DH. Differential experiences of embodiment between body-powered and myoelectric prosthesis users. Sci Rep. 2020;10(1):15471.","journal-title":"Sci Rep"},{"issue":"2","key":"1436_CR25","first-page":"17","volume":"26","author":"PM McDonnell","year":"1989","unstructured":"McDonnell PM, Scott RN, Dickison J, Theriault RA, Wood B. Do artificial limbs become part of the user? New evidence. J Rehabil Res Dev. 1989;26(2):17\u201324.","journal-title":"J Rehabil Res Dev"},{"issue":"7","key":"1436_CR26","doi-asserted-by":"publisher","first-page":"1688","DOI":"10.1523\/JNEUROSCI.05-07-01688.1985","volume":"5","author":"T Flash","year":"1985","unstructured":"Flash T, Hogan N. The coordination of arm movements: an experimentally confirmed mathematical model. J Neurosci. 1985;5(7):1688\u2013703.","journal-title":"J Neurosci"},{"issue":"4","key":"1436_CR27","doi-asserted-by":"publisher","first-page":"472","DOI":"10.1123\/mcj.8.4.472","volume":"8","author":"B Rohrer","year":"2004","unstructured":"Rohrer B, Fasoli S, Krebs HI, Volpe B, Frontera WR, Stein J, et al. Submovements grow larger, fewer, and more blended during stroke recovery. Motor Control. 2004;8(4):472\u201383.","journal-title":"Motor Control"},{"issue":"3","key":"1436_CR28","doi-asserted-by":"publisher","first-page":"235","DOI":"10.1080\/00222895.1984.10735319","volume":"16","author":"M Jeannerod","year":"1984","unstructured":"Jeannerod M. The timing of natural prehension movements. J Mot Behav. 1984;16(3):235\u201354.","journal-title":"J Mot Behav"},{"issue":"4","key":"1436_CR29","doi-asserted-by":"publisher","first-page":"589","DOI":"10.1007\/s00221-008-1394-9","volume":"188","author":"CN Schabowsky","year":"2008","unstructured":"Schabowsky CN, Dromerick AW, Holley RJ, Monroe B, Lum PS. Trans-radial upper extremity amputees are capable of adapting to a novel dynamic environment. Exp Brain Res. 2008;188(4):589\u2013601.","journal-title":"Exp Brain Res"},{"issue":"3","key":"1436_CR30","doi-asserted-by":"publisher","first-page":"201","DOI":"10.1682\/JRRD.2009.06.0075","volume":"47","author":"AJ Metzger","year":"2010","unstructured":"Metzger AJ, Dromerick AW, Schabowsky CN, Holley RJ, Monroe B, Lum PS. Feedforward control strategies of subjects with transradial amputation in planar reaching. J Rehabil Res Dev. 2010;47(3):201\u201311.","journal-title":"J Rehabil Res Dev"},{"issue":"6","key":"1436_CR31","doi-asserted-by":"publisher","first-page":"529","DOI":"10.3200\/35-09-004-RC","volume":"41","author":"N Hogan","year":"2009","unstructured":"Hogan N, Sternad D. Sensitivity of smoothness measures to movement duration, amplitude, and arrests. J Mot Behav. 2009;41(6):529\u201334.","journal-title":"J Mot Behav"},{"issue":"1","key":"1436_CR32","doi-asserted-by":"publisher","first-page":"33","DOI":"10.1177\/0309364616631348","volume":"41","author":"J Cowley","year":"2017","unstructured":"Cowley J, Resnik L, Wilken J, Smurr Walters L, Gates D. Movement quality of conventional prostheses and the DEKA arm during everyday tasks. Prosthet Orthot Int. 2017;41(1):33\u201340.","journal-title":"Prosthet Orthot Int"},{"issue":"3","key":"1436_CR33","doi-asserted-by":"publisher","first-page":"151","DOI":"10.3109\/03093648109146239","volume":"5","author":"C Fraser","year":"1981","unstructured":"Fraser C, Wing AW. A case study of reaching by a user of a manually-operated artificial hand. Prosthet Orthot Int. 1981;5(3):151\u20136.","journal-title":"Prosthet Orthot Int"},{"issue":"6","key":"1436_CR34","doi-asserted-by":"publisher","first-page":"621","DOI":"10.1109\/10.387202","volume":"42","author":"JA Doeringer","year":"1995","unstructured":"Doeringer JA, Hogan N. Performance of above elbow body-powered prostheses in visually guided unconstrained motion tasks. IEEE Trans Biomed Eng. 1995;42(6):621\u201331.","journal-title":"IEEE Trans Biomed Eng"},{"issue":"6","key":"1436_CR35","doi-asserted-by":"publisher","first-page":"523","DOI":"10.1016\/j.clinbiomech.2010.02.011","volume":"25","author":"H Bouwsema","year":"2010","unstructured":"Bouwsema H, van der Sluis CK, Bongers RM. Movement characteristics of upper extremity prostheses during basic goal-directed tasks. Clin Biomech Elsevier Ltd. 2010;25(6):523\u20139.","journal-title":"Clin Biomech Elsevier Ltd"},{"issue":"9","key":"1436_CR36","doi-asserted-by":"publisher","first-page":"1128","DOI":"10.1016\/j.clinbiomech.2008.05.008","volume":"23","author":"SL Carey","year":"2008","unstructured":"Carey SL, Jason Highsmith M, Maitland ME, Dubey RV. Compensatory movements of transradial prosthesis users during common tasks. Clin Biomech Elsevier Ltd. 2008;23(9):1128\u201335.","journal-title":"Clin Biomech Elsevier Ltd"},{"issue":"11","key":"1436_CR37","doi-asserted-by":"publisher","first-page":"2029","DOI":"10.1016\/j.apmr.2012.03.011","volume":"93","author":"AJ Metzger","year":"2012","unstructured":"Metzger AJ, Dromerick AW, Holley RJ, Lum PS. Characterization of compensatory trunk movements during prosthetic upper limb reaching tasks. Arch Phys Med Rehabil. 2012;93(11):2029\u201334.","journal-title":"Arch Phys Med Rehabil"},{"key":"1436_CR38","doi-asserted-by":"crossref","unstructured":"Major MJ, Stine RL, Heckathorne CW, Fatone S, Gard SA. Comparison of range-of-motion and variability in upper body movements between transradial prosthesis users and able-bodied controls when executing goal-oriented tasks. J Neuroeng Rehabil. 2014;11(132).","DOI":"10.1186\/1743-0003-11-132"},{"issue":"3","key":"1436_CR39","doi-asserted-by":"publisher","first-page":"286","DOI":"10.1177\/0309364616660248","volume":"41","author":"A Hussaini","year":"2017","unstructured":"Hussaini A, Zinck A, Kyberd P. Categorization of compensatory motions in transradial myoelectric prosthesis users. Prosthet Orthot Int. 2017;41(3):286\u201393.","journal-title":"Prosthet Orthot Int"},{"issue":"9","key":"1436_CR40","doi-asserted-by":"publisher","first-page":"e1911197","DOI":"10.1001\/jamanetworkopen.2019.11197","volume":"2","author":"JS Hebert","year":"2019","unstructured":"Hebert JS, Boser QA, Valevicius AM, Tanikawa H, Lavoie EB, Vette AH, et al. Quantitative Eye Gaze and Movement Differences in Visuomotor Adaptations to varying Task demands among Upper-Extremity Prosthesis users. JAMA Netw Open. 2019;2(9):e1911197.","journal-title":"JAMA Netw Open"},{"key":"1436_CR41","doi-asserted-by":"publisher","first-page":"122","DOI":"10.1016\/j.clinbiomech.2019.12.002","volume":"72","author":"AM Valevicius","year":"2020","unstructured":"Valevicius AM, Boser QA, Chapman CS, Pilarski PM, Vette AH, Hebert JS. Compensatory strategies of body-powered prosthesis users reveal primary reliance on trunk motion and relation to skill level. Clin Biomech Elsevier Ltd. 2020;72:122\u20139.","journal-title":"Clin Biomech Elsevier Ltd"},{"key":"1436_CR42","doi-asserted-by":"crossref","unstructured":"Chadwell A, Kenney LPJ, Howard D, Ssekitoleko RT, Nakandi BT, Head J. Evaluating reachable workspace and user control over prehensor aperture for a body-powered prosthesis. IEEE Trans Neural Syst Rehabil Eng. 2020;1\u20131.","DOI":"10.1109\/TNSRE.2020.3010625"},{"issue":"6","key":"1436_CR43","first-page":"243","volume":"64","author":"RB Stein","year":"1983","unstructured":"Stein RB, Walley M. Functional comparison of upper extremity amputees using myoelectric and conventional prostheses. Arch Phys Med Rehabil. 1983;64(6):243\u20138.","journal-title":"Arch Phys Med Rehabil"},{"key":"1436_CR44","doi-asserted-by":"publisher","first-page":"103228","DOI":"10.1016\/j.humov.2024.103228","volume":"96","author":"C Lee","year":"2024","unstructured":"Lee C, Gates DH. Comparison of inter-joint coordination strategies during activities of daily living with prosthetic and anatomical limbs. Hum Mov Sci. 2024;96:103228.","journal-title":"Hum Mov Sci"},{"key":"1436_CR45","doi-asserted-by":"crossref","unstructured":"\u00d8stlie K, Lesj\u00f8 IM, Franklin RJ, Garfelt B, Skjeldal OH, Magnus P. Prosthesis use in adult acquired major upper-limb amputees: patterns of wear, prosthetic skills and the actual use of prostheses in activities of daily life. Disability and Rehabilitation: Assistive Technology. 2012;7(6):479\u201393.","DOI":"10.3109\/17483107.2011.653296"},{"issue":"2","key":"1436_CR46","doi-asserted-by":"publisher","first-page":"81","DOI":"10.1177\/0309364619895201","volume":"44","author":"L Resnik","year":"2020","unstructured":"Resnik L, Borgia M, Heinemann AW, Clark MA. Prosthesis satisfaction in a national sample of veterans with upper limb amputation. Prosthet Orthot Int. 2020;44(2):81\u201391.","journal-title":"Prosthet Orthot Int"},{"key":"1436_CR47","volume-title":"The promise of assistive technology to enhance activity and work participation","year":"2017","unstructured":"National Academies of Sciences, Engineering, and Medicine. In: Jette AM, Spicer CM, Flaubert JL, editors. The promise of assistive technology to enhance activity and work participation. Washington, DC: National Academies; 2017."},{"key":"1436_CR48","doi-asserted-by":"crossref","unstructured":"Parr JVV, Wright DJ, Uiga L, Marshall B, Mohamed MO, Wood G. A scoping review of the application of motor learning principles to optimize myoelectric prosthetic hand control. Prosthetics and Orthotics International [Internet]. 2022;46(3). https:\/\/journals.lww.com\/poijournal\/fulltext\/2022\/06000\/a_scoping_review_of_the_application_of_motor.10.aspx","DOI":"10.1097\/PXR.0000000000000083"},{"issue":"9","key":"1436_CR49","doi-asserted-by":"publisher","first-page":"1331","DOI":"10.1682\/JRRD.2011.09.0179","volume":"49","author":"H Bouwsema","year":"2012","unstructured":"Bouwsema H, Kyberd PJ, Hill W, van der Sluis CK, Bongers RM. Determining skill level in myoelectric prosthesis use with multiple outcome measures. J Rehabil Res Dev. 2012;49(9):1331\u201348.","journal-title":"J Rehabil Res Dev"},{"issue":"3","key":"1436_CR50","doi-asserted-by":"publisher","first-page":"789","DOI":"10.1109\/TBME.2022.3202250","volume":"70","author":"I Vujaklija","year":"2023","unstructured":"Vujaklija I, Jung MK, Hasenoehrl T, Roche AD, Sturma A, Muceli S, et al. Biomechanical analysis of body movements of myoelectric prosthesis users during standardized clinical tests. IEEE Trans Biomed Eng. 2023;70(3):789\u201399.","journal-title":"IEEE Trans Biomed Eng"},{"issue":"11","key":"1436_CR51","doi-asserted-by":"publisher","first-page":"e0277917","DOI":"10.1371\/journal.pone.0277917","volume":"17","author":"A Touillet","year":"2022","unstructured":"Touillet A, Gouzien A, Badin M, Herbe P, Martinet N, Jarrass\u00e9 N, et al. Kinematic analysis of impairments and compensatory motor behavior during prosthetic grasping in below-elbow amputees. PLoS ONE. 2022;17(11):e0277917.","journal-title":"PLoS ONE"},{"key":"1436_CR52","doi-asserted-by":"crossref","unstructured":"Spiers A, Cochran J, Resnik L, Dollar A. Quantifying Prosthetic and Intact Limb Use in Upper Limb amputees via Egocentric Video: an unsupervised, At-Home study. IEEE Trans Med Rob Bionics. 2021;1\u20131.","DOI":"10.1109\/TMRB.2021.3072253"},{"issue":"2228","key":"1436_CR53","doi-asserted-by":"publisher","first-page":"20210005","DOI":"10.1098\/rsta.2021.0005","volume":"380","author":"H Wu","year":"2022","unstructured":"Wu H, Dyson M, Nazarpour K. Internet of things for beyond-the-laboratory prosthetics research. Philosophical Trans Royal Soc A: Math Phys Eng Sci. 2022;380(2228):20210005.","journal-title":"Philosophical Trans Royal Soc A: Math Phys Eng Sci"},{"key":"1436_CR54","unstructured":"Young BH, The Bionic-Hand Arms Race. 2022 Aug 21 [cited 2023 Apr 26];IEEE Spectrum. https:\/\/spectrum.ieee.org\/bionic-hand-design#toggle-gdpr"},{"issue":"1","key":"1436_CR55","doi-asserted-by":"publisher","first-page":"3","DOI":"10.1177\/0954411917744585","volume":"232","author":"NA Hashim","year":"2018","unstructured":"Hashim NA, Abd Razak NA, Abu Osman NA, Gholizadeh H. Improvement on upper limb body-powered prostheses (1921\u20132016): a systematic review. Proc Inst Mech Eng H. 2018;232(1):3\u201311.","journal-title":"Proc Inst Mech Eng H"},{"issue":"1","key":"1436_CR56","doi-asserted-by":"publisher","first-page":"53","DOI":"10.1186\/s12984-015-0044-2","volume":"12","author":"S Engdahl","year":"2015","unstructured":"Engdahl S, Christie B, Kelly B, Davis A, Chestek C, Gates D. Surveying the interest of individuals with upper limb loss in novel prosthetic control techniques. J Neuroeng Rehabil. 2015;12(1):53.","journal-title":"J Neuroeng Rehabil"},{"issue":"4","key":"1436_CR57","doi-asserted-by":"publisher","first-page":"706","DOI":"10.1016\/j.dhjo.2019.03.009","volume":"12","author":"JY Zheng","year":"2019","unstructured":"Zheng JY, Kalpakjian C, Larr\u00e1ga-Mart\u00ednez M, Chestek CA, Gates DH. Priorities for the design and control of upper limb prostheses: a focus group study. Disabil Health J. 2019;12(4):706\u201311.","journal-title":"Disabil Health J"}],"container-title":["Journal of NeuroEngineering and Rehabilitation"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12984-024-01436-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12984-024-01436-4\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12984-024-01436-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,8,8]],"date-time":"2024-08-08T05:10:02Z","timestamp":1723093802000},"score":1,"resource":{"primary":{"URL":"https:\/\/jneuroengrehab.biomedcentral.com\/articles\/10.1186\/s12984-024-01436-4"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,8,8]]},"references-count":57,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2024,12]]}},"alternative-id":["1436"],"URL":"https:\/\/doi.org\/10.1186\/s12984-024-01436-4","relation":{},"ISSN":["1743-0003"],"issn-type":[{"value":"1743-0003","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,8,8]]},"assertion":[{"value":"20 June 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"28 July 2024","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"8 August 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"All studies were approved by the Institutional Review Board at the University of Michigan or the University of Michigan Medical School. Written informed consent was obtained from all participants prior to data collection.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"138"}}