{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,25]],"date-time":"2026-08-25T23:31:31Z","timestamp":1787700691507,"version":"build-2784847793"},"reference-count":45,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,3,24]],"date-time":"2025-03-24T00:00:00Z","timestamp":1742774400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2025,3,24]],"date-time":"2025-03-24T00:00:00Z","timestamp":1742774400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"funder":[{"name":"Ministry of Science, Technological Development and Innovation (MoSTDI) of the Republic of Serbia","award":["451-03-66\/2024-03\/200175"],"award-info":[{"award-number":["451-03-66\/2024-03\/200175"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J NeuroEngineering Rehabil"],"DOI":"10.1186\/s12984-025-01567-2","type":"journal-article","created":{"date-parts":[[2025,3,24]],"date-time":"2025-03-24T02:27:06Z","timestamp":1742783226000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":6,"title":["Efficacy of high- versus moderate-intensity spatially distributed sequential stimulation in subjects with spinal cord injury: an isometric study"],"prefix":"10.1186","volume":"22","author":[{"given":"Ehsan","family":"Jafari","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Petar","family":"Kajganic","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Vance","family":"Bergeron","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Julie","family":"Di Marco","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Amine","family":"Metani","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lana","family":"Popovic-Maneski","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,3,24]]},"reference":[{"key":"1567_CR1","unstructured":"Baker LL. Neuromuscular electrical stimulation: a practical guide. Downey, Calif.: Los Amigos Research & Education Institute, Rancho Los Amigos National Rehabilitation Center, c2000.; 2000."},{"key":"1567_CR2","doi-asserted-by":"publisher","first-page":"255","DOI":"10.1038\/sj.sc.3102091","volume":"46","author":"KT Ragnarsson","year":"2008","unstructured":"Ragnarsson KT. Functional electrical stimulation after spinal cord injury: current use, therapeutic effects and future directions. Spinal Cord. 2008;46:255\u201374.","journal-title":"Spinal Cord"},{"key":"1567_CR3","doi-asserted-by":"publisher","first-page":"327","DOI":"10.1146\/annurev.bioeng.6.040803.140103","volume":"7","author":"PH Peckham","year":"2005","unstructured":"Peckham PH, Knutson JS. Functional electrical stimulation for neuromuscular applications. Annu Rev Biomed Eng. 2005;7:327\u201360.","journal-title":"Annu Rev Biomed Eng"},{"key":"1567_CR4","doi-asserted-by":"crossref","unstructured":"Kajganic P, Bergeron V, Metani A. ICEP: an instrumented cycling ergometer platform for the assessment of advanced FES strategies. Sens (Basel). 2023;23.","DOI":"10.3390\/s23073522"},{"key":"1567_CR5","doi-asserted-by":"publisher","first-page":"1908","DOI":"10.1109\/TNSRE.2022.3188735","volume":"30","author":"E Jafari","year":"2022","unstructured":"Jafari E, Erfanian A. A distributed automatic control framework for simultaneous control of torque and cadence in functional electrical stimulation cycling. IEEE Trans Neural Syst Rehabil Eng. 2022;30:1908\u201319.","journal-title":"IEEE Trans Neural Syst Rehabil Eng"},{"key":"1567_CR6","first-page":"725","volume":"2022","author":"E Jafari","year":"2022","unstructured":"Jafari E, Aksoez EA, Kajganic P, Metani A, Popovic-Maneski L, Bergeron V. Optimization of seating position and stimulation pattern in functional electrical stimulation cycling: Simulation study. Annu Int Conf IEEE Eng Med Biol Soc. 2022;2022:725\u201331.","journal-title":"Annu Int Conf IEEE Eng Med Biol Soc"},{"key":"1567_CR7","doi-asserted-by":"publisher","first-page":"152","DOI":"10.1177\/1545968309347681","volume":"24","author":"RB Stein","year":"2010","unstructured":"Stein RB, Everaert DG, Thompson AK, Chong SL, Whittaker M, Robertson J, et al. Long-Term Therapeutic and Orthotic effects of a Foot Drop Stimulator on walking performance in Progressive and Nonprogressive Neurological disorders. Neurorehabil Neural Repair. 2010;24:152\u201367.","journal-title":"Neurorehabil Neural Repair"},{"key":"1567_CR8","doi-asserted-by":"publisher","first-page":"2818","DOI":"10.1109\/TBME.2012.2208963","volume":"59","author":"V Nekoukar","year":"2012","unstructured":"Nekoukar V, Erfanian A. A decentralized Modular Control Framework for Robust Control of FES-Activated walker-assisted paraplegic walking using terminal Sliding Mode and fuzzy Logic Control. IEEE Trans Biomed Eng. 2012;59:2818\u201327.","journal-title":"IEEE Trans Biomed Eng"},{"key":"1567_CR9","doi-asserted-by":"publisher","first-page":"66","DOI":"10.1186\/1743-0003-9-66","volume":"9","author":"NM Male\u0161evi\u0107","year":"2012","unstructured":"Male\u0161evi\u0107 NM, Maneski LZ, Ili\u0107 V, Jorgovanovi\u0107 N, Bijeli\u0107 G, Keller T, et al. A multi-pad electrode based functional electrical stimulation system for restoration of grasp. J Neuroeng Rehabil. 2012;9:66.","journal-title":"J Neuroeng Rehabil"},{"key":"1567_CR10","doi-asserted-by":"publisher","first-page":"34","DOI":"10.1186\/s12938-020-00773-4","volume":"19","author":"C Marquez-Chin","year":"2020","unstructured":"Marquez-Chin C, Popovic MR. Functional electrical stimulation therapy for restoration of motor function after spinal cord injury and stroke: a review. Biomed Eng Online. 2020;19:34.","journal-title":"Biomed Eng Online"},{"key":"1567_CR11","doi-asserted-by":"publisher","first-page":"645","DOI":"10.1179\/2045772315Y.0000000052","volume":"39","author":"SR Wilbanks","year":"2016","unstructured":"Wilbanks SR, Rogers R, Pool S, Bickel CS. Effects of functional electrical stimulation assisted rowing on aerobic fitness and shoulder pain in manual wheelchair users with spinal cord injury. J Spinal Cord Med. 2016;39:645\u201354.","journal-title":"J Spinal Cord Med"},{"key":"1567_CR12","doi-asserted-by":"publisher","first-page":"225","DOI":"10.1016\/j.pmrj.2015.10.006","volume":"8","author":"AS Gorgey","year":"2016","unstructured":"Gorgey AS, Lawrence J. Acute responses of Functional Electrical Stimulation Cycling on the ventilation-to\u2010CO 2 production ratio and substrate utilization after spinal cord Injury. PM&R. 2016;8:225\u201334.","journal-title":"PM&R"},{"key":"1567_CR13","doi-asserted-by":"publisher","first-page":"625","DOI":"10.1111\/j.1525-1594.2008.00622.x","volume":"32","author":"GM Davis","year":"2008","unstructured":"Davis GM, Hamzaid NA, Fornusek C. Cardiorespiratory, metabolic, and biomechanical responses during Functional Electrical Stimulation Leg Exercise: Health and Fitness benefits. Artif Organs. 2008;32:625\u20139.","journal-title":"Artif Organs"},{"key":"1567_CR14","doi-asserted-by":"publisher","first-page":"222","DOI":"10.1310\/sci1903-222","volume":"19","author":"D Dolbow","year":"2013","unstructured":"Dolbow D, Gorgey A, Dolbow J, Gater D. Seat pressure changes after eight weeks of Functional Electrical Stimulation Cycling: a pilot study. Top Spinal Cord Inj Rehabil. 2013;19:222\u20138.","journal-title":"Top Spinal Cord Inj Rehabil"},{"key":"1567_CR15","doi-asserted-by":"publisher","first-page":"22","DOI":"10.1007\/s002239900286","volume":"61","author":"T Mohr","year":"1997","unstructured":"Mohr T, P\u00f8denphant J, Biering\u2013S\u00f8rensen F, Galbo H, Thamsborg G, Kj\u00e6r M. Increased bone Mineral density after prolonged electrically Induced Cycle Training of Paralyzed limbs in spinal cord injured Man. Calcif Tissue Int. 1997;61:22\u20135.","journal-title":"Calcif Tissue Int"},{"key":"1567_CR16","doi-asserted-by":"publisher","first-page":"169","DOI":"10.1016\/j.bone.2008.03.004","volume":"43","author":"A Frotzler","year":"2008","unstructured":"Frotzler A, Coupaud S, Perret C, Kakebeeke TH, Hunt KJ, de Donaldson N. High-volume FES-cycling partially reverses bone loss in people with chronic spinal cord injury. Bone. 2008;43:169\u201376.","journal-title":"Bone"},{"key":"1567_CR17","doi-asserted-by":"publisher","first-page":"1090","DOI":"10.1053\/apmr.2000.7170","volume":"81","author":"M B\u00e9langer","year":"2000","unstructured":"B\u00e9langer M, Stein RB, Wheeler GD, Gordon T, Leduc B. Electrical stimulation: can it increase muscle strength and reverse osteopenia in spinal cord injured individuals? Arch Phys Med Rehabil. 2000;81:1090\u20138.","journal-title":"Arch Phys Med Rehabil"},{"key":"1567_CR18","first-page":"159","volume":"44","author":"S Ferrante","year":"2008","unstructured":"Ferrante S, Pedrocchi A, Ferrigno G, Molteni F. Cycling induced by functional electrical stimulation improves the muscular strength and the motor control of individuals with post-acute stroke. Europa Medicophysica-SIMFER 2007 award winner. Eur J Phys Rehabil Med. 2008;44:159\u201367.","journal-title":"Eur J Phys Rehabil Med"},{"key":"1567_CR19","doi-asserted-by":"publisher","first-page":"40","DOI":"10.1186\/s13643-017-0435-5","volume":"6","author":"J Eraifej","year":"2017","unstructured":"Eraifej J, Clark W, France B, Desando S, Moore D. Effectiveness of upper limb functional electrical stimulation after stroke for the improvement of activities of daily living and motor function: a systematic review and meta-analysis. Syst Rev. 2017;6:40.","journal-title":"Syst Rev"},{"key":"1567_CR20","doi-asserted-by":"publisher","first-page":"99","DOI":"10.1186\/s12984-021-00882-8","volume":"18","author":"JW van der Scheer","year":"2021","unstructured":"van der Scheer JW, Goosey-Tolfrey VL, Valentino SE, Davis GM, Ho CH. Functional electrical stimulation cycling exercise after spinal cord injury: a systematic review of health and fitness-related outcomes. J Neuroeng Rehabil. 2021;18:99.","journal-title":"J Neuroeng Rehabil"},{"key":"1567_CR21","doi-asserted-by":"publisher","first-page":"81","DOI":"10.1186\/s12938-020-00824-w","volume":"19","author":"M Milosevic","year":"2020","unstructured":"Milosevic M, Marquez-Chin C, Masani K, Hirata M, Nomura T, Popovic MR, et al. Why brain-controlled neuroprosthetics matter: mechanisms underlying electrical stimulation of muscles and nerves in rehabilitation. Biomed Eng Online. 2020;19:81.","journal-title":"Biomed Eng Online"},{"key":"1567_CR22","doi-asserted-by":"publisher","first-page":"599","DOI":"10.1152\/jn.1965.28.3.599","volume":"28","author":"E Henneman","year":"1965","unstructured":"Henneman E, Somjen G, Carpenter DO. EXCITABILITY AND INHIBITIBILITY OF MOTONEURONS OF DIFFERENT SIZES. J Neurophysiol. 1965;28:599\u2013620.","journal-title":"J Neurophysiol"},{"key":"1567_CR23","doi-asserted-by":"publisher","first-page":"2399","DOI":"10.1007\/s00421-011-2128-4","volume":"111","author":"CS Bickel","year":"2011","unstructured":"Bickel CS, Gregory CM, Dean JC. Motor unit recruitment during neuromuscular electrical stimulation: a critical appraisal. Eur J Appl Physiol. 2011;111:2399\u2013407.","journal-title":"Eur J Appl Physiol"},{"key":"1567_CR24","doi-asserted-by":"publisher","first-page":"1163","DOI":"10.1016\/j.jelekin.2010.07.015","volume":"20","author":"MJ Decker","year":"2010","unstructured":"Decker MJ, Griffin L, Abraham LD, Brandt L. Alternating stimulation of synergistic muscles during functional electrical stimulation cycling improves endurance in persons with spinal cord injury. J Electromyogr Kinesiol. 2010;20:1163\u20139.","journal-title":"J Electromyogr Kinesiol"},{"key":"1567_CR25","doi-asserted-by":"publisher","first-page":"556","DOI":"10.1002\/mus.21736","volume":"42","author":"NM Male\u0161evi\u0107","year":"2010","unstructured":"Male\u0161evi\u0107 NM, Popovi\u0107 LZ, Schwirtlich L, Popovi\u0107 DB. Distributed low-frequency functional electrical stimulation delays muscle fatigue compared to conventional stimulation. Muscle Nerve. 2010;42:556\u201362.","journal-title":"Muscle Nerve"},{"key":"1567_CR26","doi-asserted-by":"crossref","unstructured":"Popovic LZ, Malesevic NM. Muscle fatigue of quadriceps in paraplegics: Comparison between single vs. multi-pad electrode surface stimulation. 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE; 2009. pp. 6785\u20138.","DOI":"10.1109\/IEMBS.2009.5333983"},{"key":"1567_CR27","doi-asserted-by":"publisher","first-page":"196","DOI":"10.1016\/0141-5425(88)90100-8","volume":"10","author":"M Pournezam","year":"1988","unstructured":"Pournezam M, Andrews BJ, Baxendale RH, Phillips GF, Paul JP. Reduction of muscle fatigue in man by cyclical stimulation. J Biomed Eng. 1988;10:196\u2013200.","journal-title":"J Biomed Eng"},{"key":"1567_CR28","doi-asserted-by":"crossref","unstructured":"De Macedo Pinheiro L, De Sousa ACC, Bo APL. Comparing Spatially Distributed and Single Electrode Stimulation on Individuals with Spinal Cord Injury. 2020 42nd Annual International Conference of the IEEE Engineering in Medicine & Biology Society (EMBC). IEEE; 2020. pp. 3293\u20136.","DOI":"10.1109\/EMBC44109.2020.9176616"},{"key":"1567_CR29","doi-asserted-by":"publisher","first-page":"5","DOI":"10.1186\/s12984-018-0471-y","volume":"16","author":"M Laubacher","year":"2019","unstructured":"Laubacher M, Aksoez EA, Brust AK, Baumberger M, Riener R, Binder-Macleod S, et al. Stimulation of paralysed quadriceps muscles with sequentially and spatially distributed electrodes during dynamic knee extension. J Neuroeng Rehabil. 2019;16:5.","journal-title":"J Neuroeng Rehabil"},{"key":"1567_CR30","doi-asserted-by":"publisher","first-page":"1566","DOI":"10.1109\/TNSRE.2019.2923117","volume":"27","author":"MJ Wiest","year":"2019","unstructured":"Wiest MJ, Bergquist AJ, Heffernan MG, Popovic M, Masani K. Fatigue and discomfort during spatially distributed sequential stimulation of Tibialis Anterior. IEEE Trans Neural Syst Rehabil Eng. 2019;27:1566\u201373.","journal-title":"IEEE Trans Neural Syst Rehabil Eng"},{"key":"1567_CR31","doi-asserted-by":"publisher","first-page":"271","DOI":"10.1002\/mus.25465","volume":"56","author":"AJ Bergquist","year":"2017","unstructured":"Bergquist AJ, Babbar V, Ali S, Popovic MR, Masani K. Fatigue reduction during aggregated and distributed sequential stimulation. Muscle Nerve. 2017;56:271\u201381.","journal-title":"Muscle Nerve"},{"key":"1567_CR32","doi-asserted-by":"publisher","first-page":"1787","DOI":"10.1007\/s00421-017-3675-0","volume":"117","author":"M Laubacher","year":"2017","unstructured":"Laubacher M, Aks\u00f6z AE, Riener R, Binder-Macleod S, Hunt KJ. Power output and fatigue properties using spatially distributed sequential stimulation in a dynamic knee extension task. Eur J Appl Physiol. 2017;117:1787\u201398.","journal-title":"Eur J Appl Physiol"},{"key":"1567_CR33","doi-asserted-by":"publisher","first-page":"793","DOI":"10.1007\/s00421-013-2807-4","volume":"114","author":"DG Sayenko","year":"2014","unstructured":"Sayenko DG, Nguyen R, Popovic MR, Masani K. Reducing muscle fatigue during transcutaneous neuromuscular electrical stimulation by spatially and sequentially distributing electrical stimulation sources. Eur J Appl Physiol. 2014;114:793\u2013804.","journal-title":"Eur J Appl Physiol"},{"key":"1567_CR34","doi-asserted-by":"publisher","first-page":"964","DOI":"10.1109\/TNSRE.2014.2364735","volume":"23","author":"RJ Downey","year":"2015","unstructured":"Downey RJ, Bellman MJ, Kawai H, Gregory CM, Dixon WE. Comparing the Induced muscle fatigue between Asynchronous and Synchronous Electrical Stimulation in able-bodied and spinal cord injured populations. IEEE Trans Neural Syst Rehabil Eng. 2015;23:964\u201372.","journal-title":"IEEE Trans Neural Syst Rehabil Eng"},{"key":"1567_CR35","doi-asserted-by":"crossref","unstructured":"Sayenko DG, Popovic MR, Masani K. Spatially distributed sequential stimulation reduces muscle fatigue during neuromuscular electrical stimulation. 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC). IEEE; 2013. pp. 3614\u20137.","DOI":"10.1109\/EMBC.2013.6610325"},{"key":"1567_CR36","doi-asserted-by":"publisher","first-page":"1174","DOI":"10.1111\/j.1525-1594.2010.01195.x","volume":"35","author":"R Nguyen","year":"2011","unstructured":"Nguyen R, Masani K, Micera S, Morari M, Popovic MR. Spatially distributed sequential stimulation reduces fatigue in paralyzed triceps Surae muscles: a Case Study. Artif Organs. 2011;35:1174\u201380.","journal-title":"Artif Organs"},{"key":"1567_CR37","doi-asserted-by":"publisher","first-page":"45","DOI":"10.1186\/s12984-022-01014-6","volume":"19","author":"S Baptista","year":"2022","unstructured":"Baptista S, Moreira RCC, Pinheiro MDM, Pereira LR, Carmona TG, Freire GPD. User-centered design and spatially-distributed sequential electrical stimulation in cycling for individuals with paraplegia. J Neuroeng Rehabil. 2022;19:45.","journal-title":"J Neuroeng Rehabil"},{"key":"1567_CR38","doi-asserted-by":"publisher","first-page":"11","DOI":"10.1186\/s12984-021-00805-7","volume":"18","author":"M Schmoll","year":"2021","unstructured":"Schmoll M, Le Guillou R, Lobato Borges D, Fattal C, Fachin-Martins E, Azevedo Coste C. Standardizing fatigue-resistance testing during electrical stimulation of paralysed human quadriceps muscles, a practical approach. J Neuroeng Rehabil. 2021;18:11.","journal-title":"J Neuroeng Rehabil"},{"key":"1567_CR39","doi-asserted-by":"crossref","unstructured":"Ceroni I, Ferrante S, Conti F, No SJ, Gasperina SD, Dell\u2019Eva F et al. Comparing Fatigue Reducing Stimulation Strategies During Cycling Induced by Functional Electrical Stimulation: a Case Study with one Spinal Cord Injured Subject. 2021 43rd Annual International Conference of the IEEE Engineering in Medicine & Biology Society (EMBC). IEEE; 2021. pp. 6394\u20137.","DOI":"10.1109\/EMBC46164.2021.9630197"},{"key":"1567_CR40","doi-asserted-by":"publisher","first-page":"2578","DOI":"10.1109\/TNSRE.2021.3133508","volume":"29","author":"S Agotici","year":"2021","unstructured":"Agotici S, Masani K, Yoo PB. Computational study on Spatially Distributed Sequential Stimulation for Fatigue Resistant Neuromuscular Electrical Stimulation. IEEE Trans Neural Syst Rehabil Eng. 2021;29:2578\u201386.","journal-title":"IEEE Trans Neural Syst Rehabil Eng"},{"key":"1567_CR41","doi-asserted-by":"publisher","first-page":"1970","DOI":"10.1111\/aor.14379","volume":"46","author":"L Popovi\u0107-Maneski","year":"2022","unstructured":"Popovi\u0107-Maneski L, Mateo S. MotiMove: Multi\u2010purpose transcutaneous functional electrical stimulator. Artif Organs. 2022;46:1970\u20139.","journal-title":"Artif Organs"},{"key":"1567_CR42","doi-asserted-by":"crossref","unstructured":"Laubacher M, Aks\u00f6z EA, Binder-Macleod S, Hunt KJ. Comparison of proximally versus distally placed spatially distributed sequential stimulation electrodes in a dynamic knee extension task. Eur J Transl Myol. 2016;26.","DOI":"10.4081\/ejtm.2016.6016"},{"key":"1567_CR43","doi-asserted-by":"publisher","first-page":"2461","DOI":"10.1007\/s00421-011-2093-y","volume":"111","author":"A Botter","year":"2011","unstructured":"Botter A, Oprandi G, Lanfranco F, Allasia S, Maffiuletti NA, Minetto MA. Atlas of the muscle motor points for the lower limb: implications for electrical stimulation procedures and electrode positioning. Eur J Appl Physiol. 2011;111:2461\u201371.","journal-title":"Eur J Appl Physiol"},{"key":"1567_CR44","doi-asserted-by":"publisher","unstructured":"Sayenko DG, Nguyen R, Hirabayashi T, Popovic MR, Masani K. Method to Reduce Muscle Fatigue During Transcutaneous Neuromuscular Electrical Stimulation in Major Knee and Ankle Muscle Groups. Neurorehabil Neural Repair [Internet]. 2014;29:722\u201333. Available from: https:\/\/doi.org\/10.1177\/1545968314565463","DOI":"10.1177\/1545968314565463"},{"key":"1567_CR45","doi-asserted-by":"publisher","first-page":"999","DOI":"10.1109\/TNSRE.2022.3166710","volume":"30","author":"G Ye","year":"2022","unstructured":"Ye G, Theventhiran P, Masani K. Effect of spatially distributed sequential stimulation on fatigue in functional electrical stimulation rowing. IEEE Trans Neural Syst Rehabil Eng. 2022;30:999\u20131008.","journal-title":"IEEE Trans Neural Syst Rehabil Eng"}],"container-title":["Journal of NeuroEngineering and Rehabilitation"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12984-025-01567-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12984-025-01567-2\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12984-025-01567-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,3,24]],"date-time":"2025-03-24T02:27:15Z","timestamp":1742783235000},"score":1,"resource":{"primary":{"URL":"https:\/\/jneuroengrehab.biomedcentral.com\/articles\/10.1186\/s12984-025-01567-2"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,3,24]]},"references-count":45,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["1567"],"URL":"https:\/\/doi.org\/10.1186\/s12984-025-01567-2","relation":{},"ISSN":["1743-0003"],"issn-type":[{"value":"1743-0003","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,3,24]]},"assertion":[{"value":"10 September 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"30 January 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"24 March 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The project was conducted in accordance with the Declaration of Helsinki, approved by the local Institutional Review Board, and registered at ClinicalTrials.gov (NCT06421753). In addition, written informed consent was obtained from all subjects. The participants were assured that their information would only be used for analysis in this study. All methods were carried out under relevant guidelines and regulations.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable as all participants have been de-identified.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"65"}}