{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,25]],"date-time":"2026-08-25T16:23:57Z","timestamp":1787675037746,"version":"build-2784847793"},"reference-count":90,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,8,25]],"date-time":"2026-08-25T00:00:00Z","timestamp":1787616000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2026,8,25]],"date-time":"2026-08-25T00:00:00Z","timestamp":1787616000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"funder":[{"DOI":"10.13039\/100023581","name":"National Science Foundation Graduate Research Fellowship Program","doi-asserted-by":"publisher","award":["DGE- 1841052"],"award-info":[{"award-number":["DGE- 1841052"]}],"id":[{"id":"10.13039\/100023581","id-type":"DOI","asserted-by":"publisher"}]},{"name":"Michigan Translational Research and Commercialization Award from the MTRAC Life Sciences Hub"},{"DOI":"10.13039\/100009633","name":"Eunice Kennedy Shriver National Institute of Child Health and Human Development","doi-asserted-by":"publisher","award":["AWD 1F31HD115309-01"],"award-info":[{"award-number":["AWD 1F31HD115309-01"]}],"id":[{"id":"10.13039\/100009633","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J NeuroEngineering Rehabil"],"DOI":"10.1186\/s12984-025-01805-7","type":"journal-article","created":{"date-parts":[[2026,8,25]],"date-time":"2026-08-25T04:01:33Z","timestamp":1787630493000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["The variable stiffness orthosis: customizable mechanics for assistance and rehabilitation"],"prefix":"10.1186","volume":"23","author":[{"given":"Nikko","family":"Van Crey","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David","family":"Lam","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Emily","family":"Bywater","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Max","family":"Shepherd","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Elliott","family":"Rouse","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,8,25]]},"reference":[{"issue":"32","key":"1805_CR1","doi-asserted-by":"publisher","first-page":"882","DOI":"10.15585\/mmwr.mm6732a3","volume":"67","author":"CA Okoro","year":"2018","unstructured":"Okoro CA, Hollis ND, Cyrus AC, Griffin-Blake S. Prevalence of disabilities and health care access by disability status and type among adults-united states, 2016. Morb Mortal Wkly Rep. 2018;67(32):882.","journal-title":"Morb Mortal Wkly Rep"},{"issue":"3","key":"1805_CR2","doi-asserted-by":"publisher","first-page":"259","DOI":"10.1111\/j.1085-9489.2005.10304.x","volume":"10","author":"I Aprile","year":"2005","unstructured":"Aprile I, Caliandro P, La Torre G, Tonali P, Foschini M, Mondelli M, et al. Multicenter study of peroneal mononeuropathy: clinical, neurophysiologic, and quality of life assessment. J Peripher Nerv Syst. 2005;10(3):259\u201368.","journal-title":"J Peripher Nerv Syst"},{"issue":"175","key":"1805_CR3","doi-asserted-by":"publisher","first-page":"147","DOI":"10.1097\/00003086-198305000-00021","volume":"1976\u20132007","author":"DA Winter","year":"1983","unstructured":"Winter DA. Energy generation and absorption at the ankle and knee during fast, natural, and slow cadences. Clin Orthop Relat Res. 1983;1976\u20132007(175):147\u201354.","journal-title":"Clin Orthop Relat Res"},{"issue":"19","key":"1805_CR4","doi-asserted-by":"publisher","first-page":"3361","DOI":"10.1242\/jeb.003970","volume":"210","author":"P DeVita","year":"2007","unstructured":"DeVita P, Helseth J, Hortobagyi T. Muscles do more positive than negative work in human locomotion. J Exp Biol. 2007;210(19):3361\u201373.","journal-title":"J Exp Biol"},{"key":"1805_CR5","doi-asserted-by":"publisher","first-page":"162","DOI":"10.1016\/j.gaitpost.2024.04.034","volume":"111","author":"N Waterval","year":"2024","unstructured":"Waterval N, Nollet F, Brehm M. Effect of stiffness-optimized ankle foot orthoses on joint work in adults with neuromuscular diseases is related to severity of push-off deficits. Gait & Posture. 2024;111:162\u20138.","journal-title":"Gait & Posture"},{"key":"1805_CR6","volume-title":"Gait Analysis. Normal and Pathological Function","author":"J Perry","year":"1992","unstructured":"Perry J, Burnfield JM. Gait Analysis. Normal and Pathological Function. 1st ed. Thorofare, NJ: SLACK Incorporated; 1992.","edition":"1"},{"key":"1805_CR7","volume-title":"Whittle\u2019s Gait Analysis","author":"D Levine","year":"2012","unstructured":"Levine D, Richards J, Whittle M. Whittle\u2019s Gait Analysis. 5th ed. Amsterdam, NL: Elsevier; 2012.","edition":"5"},{"key":"1805_CR8","unstructured":"Bell B. Leg braces and corrective shoes. Worcester, Massachusetts: Isaiah Thomas; U.S National Library of Medicine, Accessed 18 September 2024 (1791). https:\/\/collections.nlm.nih.gov\/catalog\/nlm:nlmuid-101435355-img."},{"key":"1805_CR9","unstructured":"Science Museum Group: Lord Byron\u2019s orthopaedic boot, England, 1781-1810. Accessed 18 September 2024 (2024). https:\/\/collection.sciencemuseumgroup.org.uk\/objects\/co127458\/lord-byrons-orthopaedic-boot-england-1781-1810."},{"key":"1805_CR10","first-page":"16","volume":"26","author":"J Glancy","year":"1972","unstructured":"Glancy J. The polypropylene solidankle orthosis. J Orthot Prostet. 1972;26:16.","journal-title":"J Orthot Prostet"},{"issue":"1","key":"1805_CR11","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s12984-021-00954-9","volume":"18","author":"G Orekhov","year":"2021","unstructured":"Orekhov G, Fang Y, Cuddeback CF, Lerner ZF. Usability and performance validation of an ultra-lightweight and versatile untethered robotic ankle exoskeleton. J Neuroeng Rehabil. 2021;18(1):1\u201316.","journal-title":"J Neuroeng Rehabil"},{"issue":"1","key":"1805_CR12","first-page":"1","volume":"11","author":"LM Mooney","year":"2014","unstructured":"Mooney LM, Rouse EJ, Herr HM. Autonomous exoskeleton reduces metabolic cost of human walking during load carriage. J Neuroeng Rehabil. 2014;11(1):1\u201311.","journal-title":"J Neuroeng Rehabil"},{"key":"1805_CR13","doi-asserted-by":"crossref","unstructured":"Hitt J, Oymagil AM, Sugar T, Hollander K, Boehler A, Fleeger J. Dynamically controlled ankle-foot orthosis (dco) with regenerative kinetics: Incrementally attaining user portability. In: Proceedings 2007 IEEE International Conference on Robotics and Automation, 2007:1541\u20131546. IEEE.","DOI":"10.1109\/ROBOT.2007.363543"},{"issue":"7931","key":"1805_CR14","doi-asserted-by":"publisher","first-page":"277","DOI":"10.1038\/s41586-022-05191-1","volume":"610","author":"P Slade","year":"2022","unstructured":"Slade P, Kochenderfer MJ, Delp SL, Collins SH. Personalizing exoskeleton assistance while walking in the real world. Nature. 2022;610(7931):277\u201382.","journal-title":"Nature"},{"issue":"10","key":"1805_CR15","doi-asserted-by":"publisher","first-page":"879","DOI":"10.1177\/0269215513486497","volume":"27","author":"S Tyson","year":"2013","unstructured":"Tyson S, Sadeghi-Demneh E, Nester C. A systematic review and meta-analysis of the effect of an ankle-foot orthosis on gait biomechanics after stroke. Clin Rehabil. 2013;27(10):879\u201391.","journal-title":"Clin Rehabil"},{"issue":"3","key":"1805_CR16","doi-asserted-by":"publisher","first-page":"293","DOI":"10.3109\/03093646.2010.495969","volume":"34","author":"DJ Bregman","year":"2010","unstructured":"Bregman DJ, De Groot V, Van Diggele P, Meulman H, Houdijk H, Harlaar J. Polypropylene ankle foot orthoses to overcome drop-foot gait in central neurological patients: a mechanical and functional evaluation. Prosthet Orthot Int. 2010;34(3):293\u2013304.","journal-title":"Prosthet Orthot Int"},{"key":"1805_CR17","doi-asserted-by":"publisher","first-page":"15","DOI":"10.1016\/j.gaitpost.2017.03.028","volume":"55","author":"CD Nikamp","year":"2017","unstructured":"Nikamp CD, Hobbelink MS, Palen J, Hermens HJ, Rietman JS, Buurke JH. A randomized controlled trial on providing ankle-foot orthoses in patients with (sub-) acute stroke: Short-term kinematic and spatiotemporal effects and effects of timing. Gait & posture. 2017;55:15\u201322.","journal-title":"Gait & posture"},{"issue":"3","key":"1805_CR18","doi-asserted-by":"publisher","first-page":"277","DOI":"10.3109\/03093646.2010.501512","volume":"34","author":"SJ Mulroy","year":"2010","unstructured":"Mulroy SJ, Eberly VJ, Gronely JK, Weiss W, Newsam CJ. Effect of afo design on walking after stroke: impact of ankle plantar flexion contracture. Prosthet Orthot Int. 2010;34(3):277\u201392.","journal-title":"Prosthet Orthot Int"},{"issue":"9","key":"1805_CR19","doi-asserted-by":"publisher","first-page":"1175","DOI":"10.1177\/0269215518771824","volume":"32","author":"M Lintanf","year":"2018","unstructured":"Lintanf M, Bourseul J-S, Houx L, Lempereur M, Brochard S, Pons C. Effect of ankle-foot orthoses on gait, balance and gross motor function in children with cerebral palsy: a systematic review and meta-analysis. Clin Rehabil. 2018;32(9):1175\u201388.","journal-title":"Clin Rehabil"},{"issue":"3","key":"1805_CR20","doi-asserted-by":"publisher","first-page":"218","DOI":"10.1097\/PEP.0000000000000153","volume":"27","author":"TA Wren","year":"2015","unstructured":"Wren TA, Dryden JW, Mueske NM, Dennis SW, Healy BS, Rethlefsen SA. Comparison of 2 orthotic approaches in children with cerebral palsy. Pediatr Phys Ther. 2015;27(3):218\u201326.","journal-title":"Pediatr Phys Ther"},{"issue":"3","key":"1805_CR21","doi-asserted-by":"publisher","first-page":"303","DOI":"10.1016\/j.gaitpost.2004.03.004","volume":"21","author":"SA Radtka","year":"2005","unstructured":"Radtka SA, Skinner SR, Johanson ME. A comparison of gait with solid and hinged ankle-foot orthoses in children with spastic diplegic cerebral palsy. Gait & posture. 2005;21(3):303\u201310.","journal-title":"Gait & posture"},{"issue":"6","key":"1805_CR22","doi-asserted-by":"publisher","first-page":"412","DOI":"10.1038\/sc.2015.238","volume":"54","author":"M Arazpour","year":"2016","unstructured":"Arazpour M, Samadian M, Ebrahimzadeh K, Ahmadi Bani M, Hutchins S. The influence of orthosis options on walking parameters in spinal cord-injured patients: a literature review. Spinal cord. 2016;54(6):412\u201322.","journal-title":"Spinal cord"},{"key":"1805_CR23","unstructured":"Davidson E, Bowers R. A systematic literature review comparing ankle-foot orthoses and functional electrical stimulation in the treatment of patients with multiple sclerosis. In: ISPO 2013 World Congress 2013."},{"key":"1805_CR24","doi-asserted-by":"publisher","DOI":"10.1016\/j.foot.2021.101898","volume":"50","author":"E Esfandiari","year":"2022","unstructured":"Esfandiari E, Saeedi H, Ahmadi A, Jalali M, Pour AM, Abdollah V. Investigating the effects of conventional thermoplastic ankle-foot and the neoprene ankle-foot orthoses on the kinetics and kinematics of gait in people with foot drop following traumatic injury of the peroneal nerve: A pilot study. Foot. 2022;50:101898.","journal-title":"Foot"},{"issue":"7","key":"1805_CR25","doi-asserted-by":"publisher","first-page":"1377","DOI":"10.1016\/j.apmr.2012.12.025","volume":"94","author":"SF Tyson","year":"2013","unstructured":"Tyson SF, Kent RM. Effects of an ankle-foot orthosis on balance and walking after stroke: a systematic review and pooled meta-analysis. Arch Phys Med Rehabil. 2013;94(7):1377\u201385.","journal-title":"Arch Phys Med Rehabil"},{"issue":"11","key":"1805_CR26","first-page":"763","volume":"68","author":"JF Lehmann","year":"1987","unstructured":"Lehmann JF, Condon SM, Price R, et al. Gait abnormalities in hemiplegia: their correction by ankle-foot orthoses. Arch Phys Med Rehabil. 1987;68(11):763\u201371.","journal-title":"Arch Phys Med Rehabil"},{"issue":"3","key":"1805_CR27","doi-asserted-by":"publisher","first-page":"193","DOI":"10.1620\/tjem.218.193","volume":"218","author":"H Abe","year":"2009","unstructured":"Abe H, Michimata A, Sugawara K, Sugaya N, Izumi S-I. Improving gait stability in stroke hemiplegic patients with a plastic ankle-foot orthosis. Tohoku J Exp Med. 2009;218(3):193\u20139.","journal-title":"Tohoku J Exp Med"},{"issue":"2","key":"1805_CR28","doi-asserted-by":"publisher","first-page":"320","DOI":"10.1097\/00005768-200102000-00023","volume":"33","author":"D Maltais","year":"2001","unstructured":"Maltais D, Bar-Or O, Galea V, Pierrynowski M. Use of orthoses lowers the o (2) cost of walking in children with spastic cerebral palsy. Med Sci Sports Exerc. 2001;33(2):320\u20135.","journal-title":"Med Sci Sports Exerc"},{"issue":"1","key":"1805_CR29","doi-asserted-by":"publisher","first-page":"148","DOI":"10.1016\/j.gaitpost.2011.08.026","volume":"35","author":"D Bregman","year":"2012","unstructured":"Bregman D, Harlaar J, Meskers C, De Groot V. Spring-like ankle foot orthoses reduce the energy cost of walking by taking over ankle work. Gait & posture. 2012;35(1):148\u201353.","journal-title":"Gait & posture"},{"key":"1805_CR30","doi-asserted-by":"publisher","first-page":"68","DOI":"10.1016\/j.ejpn.2020.02.009","volume":"26","author":"P Meyns","year":"2020","unstructured":"Meyns P, Kerkum Y, Brehm M, Becher J, Buizer A, Harlaar J. Ankle foot orthoses in cerebral palsy: effects of ankle stiffness on trunk kinematics, gait stability and energy cost of walking. Eur J Paediatr Neurol. 2020;26:68\u201374.","journal-title":"Eur J Paediatr Neurol"},{"issue":"2","key":"1805_CR31","first-page":"78","volume":"22","author":"J Lewallen","year":"2010","unstructured":"Lewallen J, Miedaner J, Amyx S, Sherman J. Effect of three styles of custom ankle foot orthoses on the gait of stroke patients while walking on level and inclined surfaces. JPO: J Prosthetics Orthot. 2010;22(2):78\u201383.","journal-title":"JPO: J Prosthetics Orthot"},{"issue":"10","key":"1805_CR32","doi-asserted-by":"publisher","first-page":"1009","DOI":"10.1016\/j.clinbiomech.2015.09.013","volume":"30","author":"D Wilk","year":"2015","unstructured":"Wilk D, Dijkstra PU, Postema K, Verkerke GJ, Hijmans JM. Effects of ankle foot orthoses on body functions and activities in people with floppy paretic ankle muscles: a systematic review. Clin Biomech. 2015;30(10):1009\u201325.","journal-title":"Clin Biomech"},{"key":"1805_CR33","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s12984-019-0600-2","volume":"16","author":"NF Waterval","year":"2019","unstructured":"Waterval NF, Nollet F, Harlaar J, Brehm M-A. Modifying ankle foot orthosis stiffness in patients with calf muscle weakness: gait responses on group and individual level. J Neuroeng Rehabil. 2019;16:1\u20139.","journal-title":"J Neuroeng Rehabil"},{"issue":"4","key":"1805_CR34","doi-asserted-by":"publisher","first-page":"870","DOI":"10.1109\/TNSRE.2014.2307256","volume":"22","author":"EJ Rouse","year":"2014","unstructured":"Rouse EJ, Hargrove LJ, Perreault EJ, Kuiken TA. Estimation of human ankle impedance during the stance phase of walking. IEEE Trans Neural Syst Rehabil Eng. 2014;22(4):870\u20138.","journal-title":"IEEE Trans Neural Syst Rehabil Eng"},{"issue":"5","key":"1805_CR35","doi-asserted-by":"publisher","first-page":"755","DOI":"10.1109\/TNSRE.2014.2346927","volume":"23","author":"H Lee","year":"2014","unstructured":"Lee H, Hogan N. Time-varying ankle mechanical impedance during human locomotion. IEEE Trans Neural Syst Rehabil Eng. 2014;23(5):755\u201364.","journal-title":"IEEE Trans Neural Syst Rehabil Eng"},{"issue":"1","key":"1805_CR36","doi-asserted-by":"publisher","first-page":"135","DOI":"10.1109\/TNSRE.2017.2758325","volume":"26","author":"AL Shorter","year":"2017","unstructured":"Shorter AL, Rouse EJ. Mechanical impedance of the ankle during the terminal stance phase of walking. IEEE Trans Neural Syst Rehabil Eng. 2017;26(1):135\u201343.","journal-title":"IEEE Trans Neural Syst Rehabil Eng"},{"issue":"1","key":"1805_CR37","doi-asserted-by":"publisher","first-page":"282","DOI":"10.1038\/s41597-021-01057-9","volume":"8","author":"E Reznick","year":"2021","unstructured":"Reznick E, Embry KR, Neuman R, Bol\u00edvar-Nieto E, Fey NP, Gregg RD. Lower-limb kinematics and kinetics during continuously varying human locomotion. Sci Data. 2021;8(1):282.","journal-title":"Sci Data"},{"issue":"1","key":"1805_CR38","doi-asserted-by":"publisher","first-page":"704","DOI":"10.1038\/s41597-022-01817-1","volume":"9","author":"TJ Zee","year":"2022","unstructured":"Zee TJ, Mundinger EM, Kuo AD. A biomechanics dataset of healthy human walking at various speeds, step lengths and step widths. Sci Data. 2022;9(1):704.","journal-title":"Sci Data"},{"issue":"1","key":"1805_CR39","doi-asserted-by":"publisher","first-page":"924","DOI":"10.1038\/s41597-023-02840-6","volume":"10","author":"K Scherpereel","year":"2023","unstructured":"Scherpereel K, Molinaro D, Inan O, Shepherd M, Young A. A human lower-limb biomechanics and wearable sensors dataset during cyclic and non-cyclic activities. Sci Data. 2023;10(1):924.","journal-title":"Sci Data"},{"issue":"1","key":"1805_CR40","doi-asserted-by":"publisher","DOI":"10.1115\/1.4051845","volume":"144","author":"BR Shuman","year":"2022","unstructured":"Shuman BR, Russell Esposito E. Multiplanar stiffness of commercial carbon composite ankle-foot orthoses. J Biomech Eng. 2022;144(1):011004.","journal-title":"J Biomech Eng"},{"issue":"1","key":"1805_CR41","first-page":"30","volume":"28","author":"GG Bedard","year":"2016","unstructured":"Bedard GG, Motylinski J, Call B, Gao F, Gray L. Bench test validation of a dynamic posterior leaf spring ankle-foot orthosis. JPO: J Prosthetics Orthot. 2016;28(1):30\u20137.","journal-title":"JPO: J Prosthetics Orthot"},{"issue":"4","key":"1805_CR42","first-page":"98","volume":"19","author":"TF Novacheck","year":"2007","unstructured":"Novacheck TF, Beattie C, Rozumalski A, Gent G, Kroll G. Quantifying the spring-like properties of ankle-foot orthoses (afos). JPO: J Prosthetics Orthot. 2007;19(4):98\u2013103.","journal-title":"JPO: J Prosthetics Orthot"},{"issue":"3","key":"1805_CR43","first-page":"48","volume":"11","author":"R Singerman","year":"1999","unstructured":"Singerman R, Hoy DJ, Mansour JM. Design changes in ankle-foot orthosis intended to alter stiffness also alter orthosis kinematics. JPO: J Prosthetics Orthot. 1999;11(3):48\u201355.","journal-title":"JPO: J Prosthetics Orthot"},{"issue":"4","key":"1805_CR44","first-page":"211","volume":"22","author":"KZ Takahashi","year":"2010","unstructured":"Takahashi KZ, Stanhope SJ. Estimates of stiffness for ankle-foot orthoses are sensitive to loading conditions. JPO: J Prosthetics Orthot. 2010;22(4):211\u20139.","journal-title":"JPO: J Prosthetics Orthot"},{"issue":"1","key":"1805_CR45","doi-asserted-by":"publisher","first-page":"1227022","DOI":"10.1080\/23311916.2016.1227022","volume":"3","author":"M Walbran","year":"2016","unstructured":"Walbran M, Turner K, McDaid A. Customized 3d printed ankle-foot orthosis with adaptable carbon fibre composite spring joint. Cogent Eng. 2016;3(1):1227022.","journal-title":"Cogent Eng"},{"key":"1805_CR46","doi-asserted-by":"publisher","first-page":"98039","DOI":"10.1109\/ACCESS.2021.3095530","volume":"9","author":"M Yamamoto","year":"2021","unstructured":"Yamamoto M, Shimatani K, Okano H, Takemura H. Effect of ankle-foot orthosis stiffness on muscle force during gait through mechanical testing and gait simulation. IEEE Access. 2021;9:98039\u201347.","journal-title":"IEEE Access"},{"issue":"4","key":"1805_CR47","doi-asserted-by":"publisher","first-page":"721","DOI":"10.1016\/j.gaitpost.2011.02.005","volume":"33","author":"T Kobayashi","year":"2011","unstructured":"Kobayashi T, Leung AK, Akazawa Y, Hutchins SW. Design of a stiffness-adjustable ankle-foot orthosis and its effect on ankle joint kinematics in patients with stroke. Gait & posture. 2011;33(4):721\u20133.","journal-title":"Gait & posture"},{"key":"1805_CR48","volume-title":"Neurological Rehabilitation: Optimizing Motor Performance","author":"JH Carr","year":"2010","unstructured":"Carr JH, Shepherd RB. Neurological Rehabilitation: Optimizing Motor Performance. Elsevier Health Sciences; 2010."},{"key":"1805_CR49","doi-asserted-by":"publisher","first-page":"111","DOI":"10.1016\/j.robot.2014.09.023","volume":"73","author":"Z Zhou","year":"2015","unstructured":"Zhou Z, Zhou Y, Wang N, Gao F, Wei K, Wang Q. A proprioceptive neuromuscular facilitation integrated robotic ankle-foot system for post stroke rehabilitation. Robot Auton Syst. 2015;73:111\u201322.","journal-title":"Robot Auton Syst"},{"issue":"6","key":"1805_CR50","doi-asserted-by":"publisher","first-page":"728","DOI":"10.1123\/jab.2014-0046","volume":"30","author":"YL Kerkum","year":"2014","unstructured":"Kerkum YL, Brehm M-A, Buizer AI, Noort JC, Becher JG, Harlaar J. Defining the mechanical properties of a spring-hinged ankle foot orthosis to assess its potential use in children with spastic cerebral palsy. J Appl Biomech. 2014;30(6):728\u201331.","journal-title":"J Appl Biomech"},{"issue":"6","key":"1805_CR51","doi-asserted-by":"publisher","first-page":"460","DOI":"10.1123\/jab.2016-0309","volume":"33","author":"T Kobayashi","year":"2017","unstructured":"Kobayashi T, Gao F, LeCursi N, Foreman KB, Orendurff MS. Effect of shoes on stiffness and energy efficiency of ankle-foot orthosis: Bench testing analysis. J Appl Biomech. 2017;33(6):460\u20133.","journal-title":"J Appl Biomech"},{"key":"1805_CR52","doi-asserted-by":"publisher","first-page":"3026","DOI":"10.1007\/s11999-014-3661-3","volume":"472","author":"E Russell Esposito","year":"2014","unstructured":"Russell Esposito E, Blanck RV, Harper NG, Hsu JR, Wilken JM. How does ankle-foot orthosis stiffness affect gait in patients with lower limb salvage? Clin Orthop Relat Res\u00ae. 2014;472:3026\u201335.","journal-title":"Clin Orthop Relat Res\u00ae"},{"issue":"22","key":"1805_CR53","first-page":"3541","volume":"218","author":"T-WP Huang","year":"2015","unstructured":"Huang T-WP, Shorter KA, Adamczyk PG, Kuo AD. Mechanical and energetic consequences of reduced ankle plantar-flexion in human walking. J Exp Biol. 2015;218(22):3541\u201350.","journal-title":"J Exp Biol"},{"issue":"6","key":"1805_CR54","doi-asserted-by":"publisher","first-page":"786","DOI":"10.1016\/j.humov.2009.05.001","volume":"28","author":"HC Doets","year":"2009","unstructured":"Doets HC, Vergouw D, Veeger HD, Houdijk H. Metabolic cost and mechanical work for the step-to-step transition in walking after successful total ankle arthroplasty. Hum Mov Sci. 2009;28(6):786\u201397.","journal-title":"Hum Mov Sci"},{"issue":"3","key":"1805_CR55","doi-asserted-by":"publisher","first-page":"207","DOI":"10.1016\/S0966-6362(99)00009-0","volume":"9","author":"RL Waters","year":"1999","unstructured":"Waters RL, Mulroy S. The energy expenditure of normal and pathologic gait. Gait & posture. 1999;9(3):207\u201331.","journal-title":"Gait & posture"},{"issue":"8","key":"1805_CR56","doi-asserted-by":"publisher","first-page":"809","DOI":"10.1016\/j.clinbiomech.2010.05.008","volume":"25","author":"S Van Engelen","year":"2010","unstructured":"Van Engelen S, Wajer Q, Plaat L, Doets H, Dijk CN, Houdijk H. Metabolic cost and mechanical work during walking after tibiotalar arthrodesis and the influence of footwear. Clin Biomech. 2010;25(8):809\u201315.","journal-title":"Clin Biomech"},{"issue":"14","key":"1805_CR57","doi-asserted-by":"publisher","first-page":"2405","DOI":"10.1016\/j.jbiomech.2012.06.035","volume":"45","author":"CJ Wutzke","year":"2012","unstructured":"Wutzke CJ, Sawicki GS, Lewek MD. The influence of a unilateral fixed ankle on metabolic and mechanical demands during walking in unimpaired young adults. J Biomech. 2012;45(14):2405\u201310.","journal-title":"J Biomech"},{"key":"1805_CR58","doi-asserted-by":"publisher","DOI":"10.1016\/j.mechatronics.2021.102572","volume":"77","author":"D Totah","year":"2021","unstructured":"Totah D, Menon M, Gates DH, Barton K. Design and evaluation of the smapp: a stiffness measurement apparatus for ankle-foot orthoses. Mechatron. 2021;77:102572.","journal-title":"Mechatron"},{"issue":"3","key":"1805_CR59","doi-asserted-by":"publisher","first-page":"312","DOI":"10.1016\/j.gaitpost.2009.05.018","volume":"30","author":"TH Cruz","year":"2009","unstructured":"Cruz TH, Dhaher YY. Impact of ankle-foot-orthosis on frontal plane behaviors post-stroke. Gait & posture. 2009;30(3):312\u20136.","journal-title":"Gait & posture"},{"issue":"3","key":"1805_CR60","doi-asserted-by":"publisher","first-page":"247","DOI":"10.1097\/00002060-200005000-00006","volume":"79","author":"DC Kerrigan","year":"2000","unstructured":"Kerrigan DC, Frates EP, Rogan S, Riley PO. Hip hiking and circumduction: quantitative definitions. Am J Phys Med Rehabil. 2000;79(3):247\u201352.","journal-title":"Am J Phys Med Rehabil"},{"issue":"19","key":"1805_CR61","first-page":"3106","volume":"219","author":"AR Wu","year":"2016","unstructured":"Wu AR, Kuo AD. Determinants of preferred ground clearance during swing phase of human walking. J Exp Biol. 2016;219(19):3106\u201313.","journal-title":"J Exp Biol"},{"key":"1805_CR62","doi-asserted-by":"crossref","unstructured":"Van Crey N, Cavallin M, Shepherd M, Rouse EJ. Design of a quasi-passive ankle-foot orthosis with customizable, variable stiffness. In: 2023 International Conference on Rehabilitation Robotics (ICORR), 2023:1\u20136. IEEE.","DOI":"10.1109\/ICORR58425.2023.10304820"},{"key":"1805_CR63","doi-asserted-by":"publisher","first-page":"126","DOI":"10.1016\/j.gaitpost.2023.07.156","volume":"106","author":"R Miedema","year":"2023","unstructured":"Miedema R, Waterval N, Meijneke C, Harlaar J, Nollet F, Brehm M. Adjust: A stiffness adjustable ankle-foot-orthosis for rapid human-in-the-loop orthosis selection. Gait & Posture. 2023;106:126\u20137.","journal-title":"Gait & Posture"},{"issue":"3","key":"1805_CR64","first-page":"4604","volume":"5","author":"S Kumar","year":"2020","unstructured":"Kumar S, Zwall MR, Bol\u00edvar-Nieto EA, Gregg RD, Gans N. Extremum seeking control for stiffness auto-tuning of a quasi-passive ankle exoskeleton. IEEE Robot Autom Lett. 2020;5(3):4604\u201311.","journal-title":"IEEE Robot Autom Lett"},{"key":"1805_CR65","unstructured":"Rong H, Ramezani S, Ambro A, Lei CH, Choi H. Design and characterization of a variable-stiffness ankle-foot orthosis. Prosthet Orthot Int. 2022:10\u20131097."},{"key":"1805_CR66","doi-asserted-by":"publisher","first-page":"1740","DOI":"10.1109\/LRA.2024.3349829","volume":"9","author":"S Hopkins","year":"2024","unstructured":"Hopkins S, Bowersock C, Rouse EJ, Lerner ZF. A quasi-passive robotic ankle foot orthosis with speed-adaptive stiffness. IEEE Robot Autom Lett. 2024;9:1740\u20137.","journal-title":"IEEE Robot Autom Lett"},{"issue":"12","key":"1805_CR67","doi-asserted-by":"publisher","first-page":"2375","DOI":"10.1109\/TNSRE.2017.2750113","volume":"25","author":"MK Shepherd","year":"2017","unstructured":"Shepherd MK, Rouse EJ. The vspa foot: A quasi-passive ankle-foot prosthesis with continuously variable stiffness. IEEE Trans Neural Syst Rehabil Eng. 2017;25(12):2375\u201386.","journal-title":"IEEE Trans Neural Syst Rehabil Eng"},{"key":"1805_CR68","doi-asserted-by":"publisher","DOI":"10.1017\/wtc.2021.7","volume":"2","author":"HA Quraishi","year":"2021","unstructured":"Quraishi HA, Shepherd MK, McManus L, Harlaar J, Plettenburg DH, Rouse EJ. A passive mechanism for decoupling energy storage and return in ankle-foot prostheses: A case study in recycling collision energy. Wearable Technol. 2021;2:e9.","journal-title":"Wearable Technol"},{"issue":"1","key":"1805_CR69","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s12984-023-01126-7","volume":"20","author":"BR Shuman","year":"2023","unstructured":"Shuman BR, Totah D, Gates DH, Gao F, Ries AJ, Russell Esposito E. Comparison of five different methodologies for evaluating ankle-foot orthosis stiffness. J Neuroeng Rehabil. 2023;20(1):1\u20139.","journal-title":"J Neuroeng Rehabil"},{"issue":"2","key":"1805_CR70","doi-asserted-by":"publisher","first-page":"562","DOI":"10.1109\/TBME.2012.2230261","volume":"60","author":"EJ Rouse","year":"2012","unstructured":"Rouse EJ, Gregg RD, Hargrove LJ, Sensinger JW. The difference between stiffness and quasi-stiffness in the context of biomechanical modeling. IEEE Trans Biomed Eng. 2012;60(2):562\u20138.","journal-title":"IEEE Trans Biomed Eng"},{"key":"1805_CR71","doi-asserted-by":"publisher","first-page":"94","DOI":"10.1016\/j.medengphy.2017.02.012","volume":"44","author":"T Kobayashi","year":"2017","unstructured":"Kobayashi T, Orendurff MS, Hunt G, Lincoln LS, Gao F, LeCursi N, et al. An articulated ankle-foot orthosis with adjustable plantarflexion resistance, dorsiflexion resistance and alignment: A pilot study on mechanical properties and effects on stroke hemiparetic gait. Med Eng Phys. 2017;44:94\u2013101.","journal-title":"Med Eng Phys"},{"issue":"5","key":"1805_CR72","doi-asserted-by":"publisher","first-page":"979","DOI":"10.1016\/S0022-5096(01)00116-8","volume":"50","author":"R Lakes","year":"2002","unstructured":"Lakes R, Drugan W. Dramatically stiffer elastic composite materials due to a negative stiffness phase? J Mech Phys Solids. 2002;50(5):979\u20131009.","journal-title":"J Mech Phys Solids"},{"issue":"1","key":"1805_CR73","doi-asserted-by":"publisher","first-page":"40","DOI":"10.1119\/1.1619140","volume":"72","author":"Y Wang","year":"2004","unstructured":"Wang Y, Lakes R. Extreme stiffness systems due to negative stiffness elements. Am J Phys. 2004;72(1):40\u201350.","journal-title":"Am J Phys"},{"key":"1805_CR74","unstructured":"Penguian: NURBS Toolbox by D.M. Spink. MATLABCentralFileExchange."},{"key":"1805_CR75","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s12984-018-0455-y","volume":"15","author":"E Russell Esposito","year":"2018","unstructured":"Russell Esposito E, Schmidtbauer KA, Wilken JM. Experimental comparisons of passive and powered ankle-foot orthoses in individuals with limb reconstruction. J Neuroeng Rehabil. 2018;15:1\u201310.","journal-title":"J Neuroeng Rehabil"},{"issue":"3","key":"1805_CR76","doi-asserted-by":"publisher","first-page":"1041","DOI":"10.1113\/jphysiol.2002.025049","volume":"545","author":"ID Loram","year":"2002","unstructured":"Loram ID, Lakie M. Direct measurement of human ankle stiffness during quiet standing: the intrinsic mechanical stiffness is insufficient for stability. J Physiol. 2002;545(3):1041\u201353.","journal-title":"J Physiol"},{"issue":"7555","key":"1805_CR77","doi-asserted-by":"publisher","first-page":"212","DOI":"10.1038\/nature14288","volume":"522","author":"SH Collins","year":"2015","unstructured":"Collins SH, Wiggin MB, Sawicki GS. Reducing the energy cost of human walking using an unpowered exoskeleton. Nature. 2015;522(7555):212\u20135.","journal-title":"Nature"},{"issue":"4","key":"1805_CR78","doi-asserted-by":"publisher","first-page":"712","DOI":"10.1109\/TNSRE.2019.2904924","volume":"27","author":"MB Yandell","year":"2019","unstructured":"Yandell MB, Tacca JR, Zelik KE. Design of a low profile, unpowered ankle exoskeleton that fits under clothes: overcoming practical barriers to widespread societal adoption. IEEE Trans Neural Syst Rehabil Eng. 2019;27(4):712\u201323.","journal-title":"IEEE Trans Neural Syst Rehabil Eng"},{"key":"1805_CR79","doi-asserted-by":"crossref","unstructured":"Quinto L, Pinheiro P, Goncalves SB, Roupa I, Sim\u00f5es P, Silva MT. Analysis of a passive ankle exoskeleton for reduction of metabolic costs during walking. Def Technol. 2023.","DOI":"10.1016\/j.dt.2023.11.015"},{"key":"1805_CR80","volume-title":"Artificial Intelligence \u2013 A Modern Approach","author":"S Russell","year":"2003","unstructured":"Russell S, Norvig P. Artificial Intelligence \u2013 A Modern Approach. 2nd ed. Upper Saddle River, NJ: Prentice-Hall Inc; 2003.","edition":"2"},{"issue":"1","key":"1805_CR81","doi-asserted-by":"publisher","first-page":"130","DOI":"10.1109\/TMRB.2024.3505304","volume":"7","author":"EA Bywater","year":"2024","unstructured":"Bywater EA, Van Crey N, Rouse EJ. Optimizing the mechanics of a variable-stiffness orthosis with energy recycling to mitigate foot drop. IEEE Trans Med Robot Bionic. 2024;7(1):130\u201340.","journal-title":"IEEE Trans Med Robot Bionic"},{"key":"1805_CR82","doi-asserted-by":"crossref","unstructured":"Lam DJ, Van Crey N, Rouse EJ. Accurately modeling the output torque and stiffness of ankle-foot orthoses with a compliant linkage model. In: 2025 IEEE International Conference on Robotics and Automation (ICRA). IEEE 2025.","DOI":"10.1109\/ICRA55743.2025.11128177"},{"issue":"5","key":"1805_CR83","doi-asserted-by":"publisher","first-page":"1036","DOI":"10.1109\/TNSRE.2018.2818820","volume":"26","author":"D Van Der Wilk","year":"2018","unstructured":"Van Der Wilk D, Reints R, Postema K, Gort T, Harlaar J, Hijmans JM, et al. Development of an ankle-foot orthosis that provides support for flaccid paretic plantarflexor and dorsiflexor muscles. IEEE Trans Neural Syst Rehabil Eng. 2018;26(5):1036\u201345.","journal-title":"IEEE Trans Neural Syst Rehabil Eng"},{"issue":"2","key":"1805_CR84","doi-asserted-by":"publisher","first-page":"144","DOI":"10.1016\/j.gaitpost.2009.05.012","volume":"30","author":"D Bregman","year":"2009","unstructured":"Bregman D, Rozumalski A, Koops D, De Groot V, Schwartz M, Harlaar J. A new method for evaluating ankle foot orthosis characteristics: Bruce. Gait & posture. 2009;30(2):144\u20139.","journal-title":"Gait & posture"},{"key":"1805_CR85","doi-asserted-by":"crossref","unstructured":"Gao F, Carlton W, Kapp S. Development of a motorized device for quantitative investigation of articulated afo misalignment. In: 2010 4th International Conference on Bioinformatics and Biomedical Engineering, 2010:1\u20134. IEEE.","DOI":"10.1109\/ICBBE.2010.5514982"},{"key":"1805_CR86","doi-asserted-by":"crossref","unstructured":"Azocar AF, Rouse EJ. Stiffness perception during active ankle and knee movement. IEEE Trans Biomed Eng. 2017;64(12):2949\u201356.","DOI":"10.1109\/TBME.2017.2691308"},{"key":"1805_CR87","doi-asserted-by":"crossref","unstructured":"Kerkum YL, Buizer AI, Van Den Noort JC, Becher JG, Harlaar J, Brehm M-A.The effects of varying ankle foot orthosis stiffness on gait in children withspastic cerebral palsy who walk with excessive knee flexion. PLoS ONE.2015;10(11):0142878.","DOI":"10.1371\/journal.pone.0142878"},{"key":"1805_CR88","unstructured":"Vicon Motion Systems Ltd: Nexus 2.16 Documentation: Lower Body Modeling with Plug-in Gait."},{"key":"1805_CR89","doi-asserted-by":"publisher","DOI":"10.1002\/9780470549148","volume-title":"Biomechanics and Motor Control of Human Movement","author":"DA Winter","year":"2009","unstructured":"Winter DA. Biomechanics and Motor Control of Human Movement. Hoboken, NJ: John Wiley and Sons; 2009."},{"issue":"01","key":"1805_CR90","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1142\/S0218654301000023","volume":"7","author":"J Wallner","year":"2001","unstructured":"Wallner J, Sakkalis T, Maekawa T, Pottmann H, Yu G. Self-intersections of offset curves and surfaces. Int J Shape Model. 2001;7(01):1\u201321.","journal-title":"Int J Shape Model"}],"container-title":["Journal of NeuroEngineering and Rehabilitation"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12984-025-01805-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12984-025-01805-7","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12984-025-01805-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,25]],"date-time":"2026-08-25T16:02:59Z","timestamp":1787673779000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s12984-025-01805-7"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,8,25]]},"references-count":90,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["1805"],"URL":"https:\/\/doi.org\/10.1186\/s12984-025-01805-7","relation":{},"ISSN":["1743-0003"],"issn-type":[{"value":"1743-0003","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,8,25]]},"assertion":[{"value":"2 February 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"9 November 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"25 August 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"This work was approved by the University of Michigan Institutional Review Board, and the participants gave informed, written consent.","order":1,"name":"Ethics","label":"Ethics approval and consent to participate","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"All participants gave written informed consent for the publication of the study.","order":2,"name":"Ethics","label":"Consent for publication","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"N.V.C. and E.J.R. are inventors on a patent pertaining to the VSO design. M.S. and E.J.R. are inventors on a patent pertaining to the DESR mechanism.","order":3,"name":"Ethics","label":"Competing interests","group":{"name":"EthicsHeading","label":"Declarations"}}],"article-number":"249"}}