{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,4]],"date-time":"2026-05-04T10:18:13Z","timestamp":1777889893113,"version":"3.51.4"},"reference-count":72,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,1,14]],"date-time":"2026-01-14T00:00:00Z","timestamp":1768348800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2026,4,2]],"date-time":"2026-04-02T00:00:00Z","timestamp":1775088000000},"content-version":"vor","delay-in-days":78,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"funder":[{"name":"R\u00e9gion Occitanie Grant","award":["#14352"],"award-info":[{"award-number":["#14352"]}]},{"name":"EIT Health Grant","award":["#20682"],"award-info":[{"award-number":["#20682"]}]},{"name":"EIC PathFinder","award":["#101099916 AI-Hand"],"award-info":[{"award-number":["#101099916 AI-Hand"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J NeuroEngineering Rehabil"],"DOI":"10.1186\/s12984-025-01857-9","type":"journal-article","created":{"date-parts":[[2026,1,14]],"date-time":"2026-01-14T11:54:30Z","timestamp":1768391670000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Restoring hand grasping for patients with a complete tetraplegia with selective epineural stimulation: a parsimonious thus relevant clinical approach"],"prefix":"10.1186","volume":"23","author":[{"given":"Christine","family":"Azevedo Coste","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Thomas","family":"Guiho","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Fernanda","family":"Ferreira","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Fran\u00e7ois","family":"Bailly","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Benjamin","family":"Degeorge","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Antoine","family":"Geffrier","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"David","family":"Andreu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jacques","family":"Teissier","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"David","family":"Guiraud","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Charles","family":"Fattal","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2026,1,14]]},"reference":[{"issue":"5","key":"1857_CR1","doi-asserted-by":"publisher","first-page":"896","DOI":"10.1016\/j.jcot.2019.08.001","volume":"11","author":"P Agarwal","year":"2020","unstructured":"Agarwal P, Mishra AN, Sudesh W, Prachir M, Dhananjaya S. Priorities of desired functional recovery in Indian spinal cord injury patients. J Clin Orthop Trauma. 2020;11(5):896\u20139. https:\/\/doi.org\/10.1016\/j.jcot.2019.08.001.","journal-title":"J Clin Orthop Trauma"},{"issue":"10081","key":"1857_CR2","doi-asserted-by":"publisher","first-page":"1821","DOI":"10.1016\/S0140-6736(17)30601-3","volume":"389","author":"AB Ajiboye","year":"2017","unstructured":"Ajiboye AB, Willett FR, Young DR, Memberg WD, Murphy BA, Miller JP, et al. Restoration of reaching and grasping movements through brain-controlled muscle stimulation in a person with tetraplegia: a proof-of-concept demonstration. Lancet. 2017;389(10081):1821\u201330. https:\/\/doi.org\/10.1016\/S0140-6736(17)30601-3.","journal-title":"Lancet"},{"issue":"1","key":"1857_CR3","doi-asserted-by":"publisher","first-page":"64","DOI":"10.1097\/00130911-200003000-00009","volume":"4","author":"Y Allieu","year":"2000","unstructured":"Allieu Y, Coulet B, Chammas M. Functional surgery of the upper limb in high-level tetraplegia: part II. Tech Hand Up Extrem Surg. 2000;4(1):64\u20138. https:\/\/doi.org\/10.1097\/00130911-200003000-00009.","journal-title":"Tech Hand Up Extrem Surg"},{"issue":"1","key":"1857_CR4","doi-asserted-by":"publisher","first-page":"119","DOI":"10.1053\/apmr.2003.50073","volume":"84","author":"G Alon","year":"2003","unstructured":"Alon G, McBride K. Persons with C5 or C6 tetraplegia achieve selected functional gains using a neuroprosthesis. Arch Phys Med Rehabil. 2003;84(1):119\u201324. https:\/\/doi.org\/10.1053\/apmr.2003.50073.","journal-title":"Arch Phys Med Rehabil"},{"issue":"10","key":"1857_CR5","doi-asserted-by":"publisher","first-page":"1371","DOI":"10.1089\/neu.2004.21.1371","volume":"21","author":"KD Anderson","year":"2004","unstructured":"Anderson KD. Targeting recovery: priorities of the spinal cord-injured population. J Neurotrauma. 2004;21(10):1371\u201383. https:\/\/doi.org\/10.1089\/neu.2004.21.1371.","journal-title":"J Neurotrauma"},{"key":"1857_CR6","doi-asserted-by":"publisher","first-page":"68","DOI":"10.1038\/s41394-019-0213-9","volume":"5","author":"KD Anderson","year":"2019","unstructured":"Anderson KD, Bryden AM, Moynahan M. Risk-benefit value of upper extremity function by an implanted electrical stimulation device targeting chronic cervical spinal cord injury. Spinal Cord Ser. 2019;5:68.","journal-title":"Spinal Cord Ser"},{"key":"1857_CR7","doi-asserted-by":"publisher","DOI":"10.3389\/fresc.2022.995244","volume":"3","author":"KD Anderson","year":"2022","unstructured":"Anderson KD, Korupolu R, Musselman KE, Pierce J, Wilson JR, Yozbatiran N, et al. Multi-center, single-blind randomized controlled trial comparing functional electrical stimulation therapy to conventional therapy in incomplete tetraplegia. Front Rehabil Sci. 2022;3:995244. https:\/\/doi.org\/10.3389\/fresc.2022.995244.","journal-title":"Front Rehabil Sci"},{"key":"1857_CR8","doi-asserted-by":"publisher","first-page":"16189","DOI":"10.1038\/s41598-022-19906-x","volume":"12","author":"C Azevedo Coste","year":"2022","unstructured":"Azevedo Coste C, William L, Fonseca L, et al. Activating effective functional hand movements in individuals with complete tetraplegia through neural stimulation. Sci Rep. 2022;12:16189. https:\/\/doi.org\/10.1038\/s41598-022-19906-x.","journal-title":"Sci Rep"},{"issue":"9","key":"1857_CR9","doi-asserted-by":"publisher","first-page":"812","DOI":"10.1038\/s41393-022-00795-w","volume":"60","author":"C Barbiellini Amidei","year":"2022","unstructured":"Barbiellini Amidei C, Salmaso L, Bellio S, Saia M. Epidemiology of traumatic spinal cord injury: a large population-based study. Spinal Cord. 2022;60(9):812\u20139. https:\/\/doi.org\/10.1038\/s41393-022-00795-w.","journal-title":"Spinal Cord"},{"key":"1857_CR10","doi-asserted-by":"publisher","first-page":"247","DOI":"10.1038\/nature17435","volume":"533","author":"C Bouton","year":"2016","unstructured":"Bouton C, Shaikhouni A, Annetta N, et al. Restoring cortical control of functional movement in a human with quadriplegia. Nature. 2016;533:247\u201350. https:\/\/doi.org\/10.1038\/nature17435.","journal-title":"Nature"},{"key":"1857_CR11","first-page":"189","volume-title":"Usability evaluation in industry","author":"J Brooke","year":"1996","unstructured":"Brooke J. SUS: a \u2018quick and dirty\u2019 usability scale. In: Jordan PW, Thomas B, Weerdmeester BA, McClelland I, editors. Usability evaluation in industry. London: Taylor & Francis; 1996. p. 189\u201394."},{"issue":"7","key":"1857_CR12","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.RVW.19.00210","volume":"8","author":"SR Cantwell","year":"2020","unstructured":"Cantwell SR, Rhee PC. Upper-extremity reconstruction in tetraplegia: a critical analysis review. JBJS Rev. 2020;8(7):e1900210. https:\/\/doi.org\/10.2106\/JBJS.RVW.19.00210.","journal-title":"JBJS Rev"},{"issue":"1","key":"1857_CR13","doi-asserted-by":"publisher","DOI":"10.1186\/s12984-017-0285-3","volume":"14","author":"BP Christie","year":"2017","unstructured":"Christie BP, Freeberg M, Memberg WD, Pinault GJC, Hoyen HA, Tyler DJ, et al. Long-term stability of stimulating spiral nerve cuff electrodes on human peripheral nerves. J Neuroeng Rehabil. 2017;14(1):70. https:\/\/doi.org\/10.1186\/s12984-017-0285-3.","journal-title":"J Neuroeng Rehabil"},{"issue":"1","key":"1857_CR14","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1109\/86.662614","volume":"6","author":"PE Crago","year":"1998","unstructured":"Crago PE, Memberg WD, Usey MK, Keith MW, Kirsch RF, Chapman GJ, et al. An elbow extension neuroprosthesis for individuals with tetraplegia. IEEE Trans Rehabil Eng. 1998;6(1):1\u20136. https:\/\/doi.org\/10.1109\/86.662614.","journal-title":"IEEE Trans Rehabil Eng"},{"issue":"7","key":"1857_CR15","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0219079","volume":"14","author":"M Dali","year":"2019","unstructured":"Dali M, William L, Tigra W, Taillades H, Rossel O, Azevedo C, et al. Relevance of selective neural stimulation with a multicontact cuff electrode using multicriteria analysis. PLoS ONE. 2019;14(7):e0219079. https:\/\/doi.org\/10.1371\/journal.pone.0219079.","journal-title":"PLoS ONE"},{"issue":"4","key":"1857_CR16","doi-asserted-by":"publisher","DOI":"10.1088\/1741-2552\/aabeb9","volume":"15","author":"M Dali","year":"2018","unstructured":"Dali M, Rossel O, Andreu D, Laporte L, Hern\u00e1ndez A, Laforet L, et al. Model based optimal multipolar stimulation without a priori knowledge of nerve structure: application to vagus nerve stimulation. J Neural Eng. 2018;15(4):046018. https:\/\/doi.org\/10.1088\/1741-2552\/aabeb9.","journal-title":"J Neural Eng"},{"issue":"7","key":"1857_CR17","doi-asserted-by":"publisher","first-page":"621.e1","DOI":"10.1016\/j.jhsa.2020.10.036","volume":"46","author":"J Dengler","year":"2021","unstructured":"Dengler J, Mehra M, Steeves JD, Department of Defense (DOD) Group, European Multicenter Study of Spinal Cord Injury (EMSCI) Group, Fox IK. Evaluation of functional independence in cervical spinal cord injury: implications for surgery to restore upper limb function. J Hand Surg Am. 2021;46(7):621.e1-e17. https:\/\/doi.org\/10.1016\/j.jhsa.2020.10.036.","journal-title":"J Hand Surg Am"},{"issue":"1","key":"1857_CR18","doi-asserted-by":"publisher","first-page":"75","DOI":"10.1016\/s0167-4943(96)00756-x","volume":"24","author":"J Desrosiers","year":"1997","unstructured":"Desrosiers J, Bravo G, H\u00e9bert R. Isometric grip endurance of healthy elderly men and women. Arch Gerontol Geriatr. 1997;24(1):75\u201385. https:\/\/doi.org\/10.1016\/s0167-4943(96)00756-x.","journal-title":"Arch Gerontol Geriatr"},{"key":"1857_CR19","doi-asserted-by":"publisher","DOI":"10.3390\/jcm12093150","volume":"12","author":"DR Dolbow","year":"2023","unstructured":"Dolbow DR, Gorgey AS, Johnston TE, Bersch I. Electrical stimulation exercise for people with spinal cord injury: a healthcare provider perspective. J Clin Med. 2023;12:3150. https:\/\/doi.org\/10.3390\/jcm12093150.","journal-title":"J Clin Med"},{"issue":"2","key":"1857_CR20","doi-asserted-by":"publisher","first-page":"178","DOI":"10.1016\/j.anplas.2018.11.001","volume":"64","author":"N Edery","year":"2019","unstructured":"Edery N, Revol M, Geffrier A, Rem K, Kerfant N, Cristofari S. \u00c9volution des indications chirurgicales dans la chirurgie fonctionnelle du membre sup\u00e9rieur chez le patient t\u00e9trapl\u00e9gique: \u00e9tude r\u00e9trospective \u00e0 propos de 428 interventions [Evolution of surgical indications in upper limb functional surgery for tetraplegic patients: Retrospective study of 428 procedures]. Ann Chir Plast Esthet. 2019;64(2):178\u201388. https:\/\/doi.org\/10.1016\/j.anplas.2018.11.001.","journal-title":"Ann Chir Plast Esthet"},{"issue":"5","key":"1857_CR21","doi-asserted-by":"publisher","first-page":"401","DOI":"10.1016\/j.ergon.2011.05.006","volume":"41","author":"M Eksioglu","year":"2011","unstructured":"Eksioglu M. Endurance time of grip-force as a function of grip-span, posture and anthropometric variables. Int J Ind Ergon. 2011;41(5):401\u20139. https:\/\/doi.org\/10.1016\/j.ergon.2011.05.006.","journal-title":"Int J Ind Ergon"},{"key":"1857_CR22","doi-asserted-by":"publisher","first-page":"93","DOI":"10.1682\/JRRD.2003.08.0093","volume":"40","author":"IM Estores","year":"2003","unstructured":"Estores IM. The consumer\u2019s perspective and the professional literature: what do persons with spinal cord injury want? J Rehabil Res Dev. 2003;40:93\u20138. https:\/\/doi.org\/10.1682\/JRRD.2003.08.0093.","journal-title":"J Rehabil Res Dev"},{"issue":"9","key":"1857_CR23","doi-asserted-by":"publisher","first-page":"1004","DOI":"10.1038\/s41393-020-0456-0","volume":"58","author":"C Fattal","year":"2020","unstructured":"Fattal C, Enjalbert M, Teissier J, Coulet B, Fachin-Martins E. Responsiveness of the motor capacities scale to upper limb reconstructive surgery in persons with tetraplegia due to cervical spinal cord injury. Spinal Cord. 2020;58(9):1004\u201314. https:\/\/doi.org\/10.1038\/s41393-020-0456-0.","journal-title":"Spinal Cord"},{"issue":"3","key":"1857_CR24","doi-asserted-by":"publisher","first-page":"144","DOI":"10.1016\/s0168-6054(03)00014-x","volume":"46","author":"C Fattal","year":"2003","unstructured":"Fattal C, Teissier J, Leclercq C, Revol M, Enjalbert M. Evolution de la prise en charge chirurgicale du membre sup\u00e9rieur t\u00e9trapl\u00e9gique depuis 50 ans [Functional surgery of upper limb in tetraplegics since 50 years]. Ann Readapt Med Phys. 2003;46(3):144\u201355. https:\/\/doi.org\/10.1016\/s0168-6054(03)00014-x.","journal-title":"Ann Readapt Med Phys"},{"issue":"9\u201310","key":"1857_CR25","doi-asserted-by":"publisher","first-page":"627","DOI":"10.1089\/neu.2021.0381","volume":"39","author":"C Fattal","year":"2022","unstructured":"Fattal C, Teissier J, Geffrier A, Fonseca L, William L, Andreu D, et al. Restoring hand functions in people with tetraplegia through multi-contact, fascicular, and auto-pilot stimulation: a proof-of-concept demonstration. J Neurotrauma. 2022;39(9\u201310):627\u201338. https:\/\/doi.org\/10.1089\/neu.2021.0381.","journal-title":"J Neurotrauma"},{"issue":"20","key":"1857_CR26","doi-asserted-by":"publisher","first-page":"4532","DOI":"10.3390\/s19204532","volume":"19","author":"L Fonseca","year":"2019","unstructured":"Fonseca L, Tigra W, Navarro B, Guiraud D, Fattal C, B\u00f3 A, et al. Assisted grasping in individuals with tetraplegia: improving control through residual muscle contraction and movement. Sensors. 2019;19(20):4532. https:\/\/doi.org\/10.3390\/s19204532.","journal-title":"Sensors"},{"key":"1857_CR27","doi-asserted-by":"publisher","first-page":"569","DOI":"10.1109\/TNSRE.2022.3156269","volume":"30","author":"L Fonseca","year":"2022","unstructured":"Fonseca L, Guiraud D, Hiairrassary A, Fattal C, Azevedo-Coste C. A residual movement classification based user interface for control of assistive devices by persons with complete tetraplegia. IEEE Trans Neural Syst Rehabil Eng. 2022;30:569\u201378. https:\/\/doi.org\/10.1109\/TNSRE.2022.3156269.","journal-title":"IEEE Trans Neural Syst Rehabil Eng"},{"issue":"11","key":"1857_CR28","doi-asserted-by":"publisher","first-page":"1026","DOI":"10.1016\/S1474-4422(23)00287-9","volume":"22","author":"GBD Spinal Cord Injuries Collaborators","year":"2023","unstructured":"GBD Spinal Cord Injuries Collaborators. Global, regional, and national burden of spinal cord injury, 1990\u20132019: a systematic analysis for the Global Burden of Disease Study 2019. Lancet Neurol. 2023;22(11):1026\u201347. https:\/\/doi.org\/10.1016\/S1474-4422(23)00287-9.","journal-title":"Lancet Neurol"},{"issue":"21","key":"1857_CR29","doi-asserted-by":"publisher","first-page":"7219","DOI":"10.3390\/s21217219","volume":"21","author":"T Guiho","year":"2021","unstructured":"Guiho T, L\u00f3pez-\u00c1lvarez VM, \u010cvan\u010dara P, Hiairrassary A, Andreu D, Stieglitz T, et al. New stimulation device to drive multiple transverse intrafascicular electrodes and achieve highly selective and rich neural responses. Sensors. 2021;21(21):7219.","journal-title":"Sensors"},{"key":"1857_CR30","volume-title":"Converging clinical and engineering research on neurorehabilitation II. Biosystems & biorobotics","author":"T Guiho","year":"2017","unstructured":"Guiho T, Andreu D, L\u00f3pez-Alvarez M, Cvancara P, Hiairrassary A, Wauters L, et al. Advanced 56 channels stimulation system to drive intrafascicular electrodes. In: Ib\u00e1\u00f1ez J, Gonz\u00e1lez-Vargas J, Azor\u00edn J, Akay M, Pons J, editors. Converging clinical and engineering research on neurorehabilitation II. Biosystems & biorobotics, vol. 15. Cham: Springer; 2017."},{"issue":"4","key":"1857_CR31","doi-asserted-by":"publisher","first-page":"692","DOI":"10.1016\/j.jhsa.2008.12.002","volume":"34","author":"C Hamou","year":"2009","unstructured":"Hamou C, Shah NR, DiPonio L, Curtin CM. Pinch and elbow extension restoration in people with tetraplegia: a systematic review of the literature. J Hand Surg Am. 2009;34(4):692\u20139. https:\/\/doi.org\/10.1016\/j.jhsa.2008.12.002.","journal-title":"J Hand Surg Am"},{"key":"1857_CR32","first-page":"291","volume":"57","author":"R Hanson","year":"1976","unstructured":"Hanson R, Franklin M. Sexual loss in relation to other functional losses for spinal cord injured males. Arch Phys Med Rehabil. 1976;57:291.","journal-title":"Arch Phys Med Rehabil"},{"issue":"1","key":"1857_CR33","doi-asserted-by":"publisher","first-page":"45","DOI":"10.1109\/TNSRE.2010.2079952","volume":"19","author":"RL Hart","year":"2011","unstructured":"Hart RL, Bhadra N, Montague FW, Kilgore KL, Peckham PH. Design and testing of an advanced implantable neuroprosthesis with myoelectric control. IEEE Trans Neural Syst Rehabil Eng. 2011;19(1):45\u201353.","journal-title":"IEEE Trans Neural Syst Rehabil Eng"},{"issue":"4","key":"1857_CR34","doi-asserted-by":"publisher","first-page":"864","DOI":"10.1227\/neu.0000000000002769","volume":"94","author":"EZ Herring","year":"2024","unstructured":"Herring EZ, Graczyk EL, Memberg WD, Adams R, Fernandez Baca-Vaca G, Hutchison BC, et al. Reconnecting the hand and arm to the brain: efficacy of neural interfaces for sensorimotor restoration after tetraplegia. Neurosurgery. 2024;94(4):864\u201374. https:\/\/doi.org\/10.1227\/neu.0000000000002769.","journal-title":"Neurosurgery"},{"issue":"5","key":"1857_CR35","doi-asserted-by":"publisher","first-page":"459","DOI":"10.1054\/jhsb.2001.0587","volume":"26","author":"J Hobby","year":"2001","unstructured":"Hobby J, Taylor PN, Esnouf J. Restoration of tetraplegic hand function by use of the neurocontrol freehand system. J Hand Surg Br. 2001;26(5):459\u201364. https:\/\/doi.org\/10.1054\/jhsb.2001.0587.","journal-title":"J Hand Surg Br"},{"key":"1857_CR36","first-page":"209","volume":"11","author":"N Hoshimiya","year":"1989","unstructured":"Hoshimiya N, Handa Y. A. master-slave type multichannel functional electrical stimulation (FES) system for the control of the paralyzed upper extremities. Automedica. 1989;11:209\u201320.","journal-title":"Automedica"},{"issue":"3","key":"1857_CR37","doi-asserted-by":"publisher","first-page":"355","DOI":"10.3171\/2023.4.SPINE2382","volume":"39","author":"S Javeed","year":"2023","unstructured":"Javeed S, Greenberg JK, Zhang JK, Plog B, Dibble CF, Benedict B, et al. Association of upper-limb neurological recovery with functional outcomes in high cervical spinal cord injury. J Neurosurg Spine. 2023;39(3):355\u201362. https:\/\/doi.org\/10.3171\/2023.4.SPINE2382.","journal-title":"J Neurosurg Spine"},{"issue":"524","key":"1857_CR38","first-page":"530","volume":"14A","author":"MW Keith","year":"1989","unstructured":"Keith MW, Peckham PH, Thrope GB, et al. Implantable functional neuromuscular stimulation in the tetraplegic hand. J Hand Surg. 1989;14A(524):530.","journal-title":"J Hand Surg"},{"key":"1857_CR39","doi-asserted-by":"publisher","unstructured":"Kilgore K, Peckham PH, Montague FW, Hart RL, Bryden A, Keith M, Hoyen H, Bhadra N. An implanted upper extremity neuroprosthesis utilizing myoelectric control. In: Proceedings. 2nd International IEEE EMBS, conference on neural engineering 2005, Arlington, VA, USA. 2005. p. 368\u201371. https:\/\/doi.org\/10.1109\/CNE.2005.1419634.","DOI":"10.1109\/CNE.2005.1419634"},{"key":"1857_CR40","doi-asserted-by":"publisher","first-page":"1630","DOI":"10.1109\/IEMBS.2006.259939","volume":"2006","author":"KL Kilgore","year":"2006","unstructured":"Kilgore KL, Hart RL, Montague FW, Bryden AM, Keith MW, Hoyen HA, et al. An implanted myoelectrically-controlled neuroprosthesis for upper extremity function in spinal cord injury. Conf Proc IEEE Eng Med Biol Soc. 2006;2006:1630\u20133. https:\/\/doi.org\/10.1109\/IEMBS.2006.259939.","journal-title":"Conf Proc IEEE Eng Med Biol Soc"},{"issue":"4","key":"1857_CR41","doi-asserted-by":"publisher","first-page":"539","DOI":"10.1016\/j.jhsa.2008.01.007","volume":"33","author":"KL Kilgore","year":"2008","unstructured":"Kilgore KL, Hoyen HA, Bryden AM, Hart RL, Keith MW, Peckham PH. An implanted upper-extremity neuroprosthesis using myoelectric control. J Hand Surg Am. 2008;33(4):539\u201350. https:\/\/doi.org\/10.1016\/j.jhsa.2008.01.007.","journal-title":"J Hand Surg Am"},{"issue":"4","key":"1857_CR42","doi-asserted-by":"publisher","first-page":"533","DOI":"10.2106\/00004623-199704000-00008","volume":"79","author":"KL Kilgore","year":"1997","unstructured":"Kilgore KL, Peckham PH, Keith MW, Thrope GB, Wuolle KS, Bryden AM, et al. An implanted upper-extremity neuroprosthesis. Follow-up of five patients. J Bone Jt Surg Am. 1997;79(4):533\u201341.","journal-title":"J Bone Jt Surg Am"},{"key":"1857_CR43","doi-asserted-by":"publisher","first-page":"252","DOI":"10.1310\/sci2403-252","volume":"24","author":"KL Kilgore","year":"2018","unstructured":"Kilgore KL, et al. Evolution of neuroprosthetic approaches to restoration of upper extremity function in spinal cord injury. Top Spinal Cord Inj Rehabil. 2018;24:252\u201364.","journal-title":"Top Spinal Cord Inj Rehabil"},{"key":"1857_CR44","doi-asserted-by":"publisher","DOI":"10.3389\/fneur.2022.941256","volume":"13","author":"CY Lam","year":"2022","unstructured":"Lam CY, Koljonen PA, Yip CCH, Su IYW, Hu Y, Wong YW, et al. Functional recovery priorities and community rehabilitation service preferences of spinal cord injury individuals and caregivers of Chinese ethnicity and cultural background. Front Neurol. 2022;13:941256. https:\/\/doi.org\/10.3389\/fneur.2022.941256.","journal-title":"Front Neurol"},{"issue":"1","key":"1857_CR45","doi-asserted-by":"publisher","first-page":"19","DOI":"10.1109\/86.750547","volume":"7","author":"RT Lauer","year":"1999","unstructured":"Lauer RT, Kilgore KL, Peckham PH, Bhadra N, Keith MW. The function of the finger intrinsic muscles in response to electrical stimulation. IEEE Trans Rehabil Eng. 1999;7(1):19\u201326. https:\/\/doi.org\/10.1109\/86.750547.","journal-title":"IEEE Trans Rehabil Eng"},{"issue":"4","key":"1857_CR46","doi-asserted-by":"publisher","first-page":"230","DOI":"10.1055\/s-2005-837703","volume":"37","author":"C Leclercq","year":"2005","unstructured":"Leclercq C, Memouel M-A, Albert T. Surgical rehabilitation procedures of the upper limbs in tetraplegic patients. Handchir Mikrochir Plast Chir. 2005;37(4):230\u20137. https:\/\/doi.org\/10.1055\/s-2005-837703.","journal-title":"Handchir Mikrochir Plast Chir"},{"issue":"21","key":"1857_CR47","doi-asserted-by":"publisher","first-page":"1958","DOI":"10.1089\/neu.2016.4423","volume":"33","author":"C Lo","year":"2016","unstructured":"Lo C, Tran Y, Anderson K, Craig A, Middleton J. Functional priorities in persons with spinal cord injury: using discrete choice experiments to determine preferences. J Neurotrauma. 2016;33(21):1958\u201368. https:\/\/doi.org\/10.1089\/neu.2016.4423.","journal-title":"J Neurotrauma"},{"key":"1857_CR48","doi-asserted-by":"publisher","first-page":"390","DOI":"10.1038\/s44222-023-00054-4","volume":"1","author":"E Losanno","year":"2023","unstructured":"Losanno E, Mender M, Chestek C, et al. Neurotechnologies to restore hand functions. Nat Rev Bioeng. 2023;1:390\u2013407. https:\/\/doi.org\/10.1038\/s44222-023-00054-4.","journal-title":"Nat Rev Bioeng"},{"issue":"2","key":"1857_CR49","doi-asserted-by":"publisher","first-page":"281","DOI":"10.1109\/TBCAS.2021.3066838","volume":"15","author":"N Makowski","year":"2021","unstructured":"Makowski N, Campean A, Lambrecht J, Buckett J, Coburn J, Hart R, et al. Design and testing of stimulation and myoelectric recording modules in an implanted distributed neuroprosthetic system. IEEE Trans Biomed Circuits Syst. 2021;15(2):281\u201393. https:\/\/doi.org\/10.1109\/TBCAS.2021.3066838.","journal-title":"IEEE Trans Biomed Circuits Syst"},{"issue":"1","key":"1857_CR50","doi-asserted-by":"publisher","first-page":"92","DOI":"10.1177\/00084174221142177","volume":"90","author":"MA McColl","year":"2023","unstructured":"McColl MA, Denis CB, Douglas K-L, Gilmour J, Haveman N, Petersen M, et al. A clinically significant difference on the COPM: a review. Can J Occup Ther. 2023;90(1):92\u2013102. https:\/\/doi.org\/10.1177\/00084174221142177.","journal-title":"Can J Occup Ther"},{"issue":"2","key":"1857_CR51","doi-asserted-by":"publisher","first-page":"126","DOI":"10.1109\/86.242426","volume":"1","author":"WD Memberg","year":"1993","unstructured":"Memberg WD, Peckham PH, Thrope GB, Keith MW, Kicher TP. An analysis of the reliability of percutaneous intramuscular electrodes in upper extremity FNS applications. IEEE Trans Rehabil Eng. 1993;1(2):126\u201332. https:\/\/doi.org\/10.1109\/86.242426.","journal-title":"IEEE Trans Rehabil Eng"},{"issue":"6","key":"1857_CR52","doi-asserted-by":"publisher","first-page":"1201","DOI":"10.1016\/j.apmr.2014.01.028","volume":"95","author":"WD Memberg","year":"2014","unstructured":"Memberg WD, Polasek KH, Hart RL, Bryden AM, Kilgore KL, Nemunaitis GA, et al. Implanted neuroprosthesis for restoring arm and hand function in people with high level tetraplegia. Arch Phys Med Rehabil. 2014;95(6):1201-1211.e1. https:\/\/doi.org\/10.1016\/j.apmr.2014.01.028.","journal-title":"Arch Phys Med Rehabil"},{"issue":"6","key":"1857_CR53","doi-asserted-by":"publisher","first-page":"597","DOI":"10.1016\/s0003-9993(97)90425-1","volume":"78","author":"MJ Mulcahey","year":"1997","unstructured":"Mulcahey MJ, Betz RR, Smith BT, Weiss AA, Davis SE. Implanted functional electrical stimulation hand system in adolescents with spinal injuries: an evaluation. Arch Phys Med Rehabil. 1997;78(6):597\u2013607. https:\/\/doi.org\/10.1016\/s0003-9993(97)90425-1.","journal-title":"Arch Phys Med Rehabil"},{"key":"1857_CR54","doi-asserted-by":"publisher","first-page":"54","DOI":"10.1002\/mus.21427","volume":"41","author":"M Papaiordanidou","year":"2010","unstructured":"Papaiordanidou M, Guiraud D, Varray A. Kinetics of neuromuscular changes during low-frequency electrical stimulation. Muscle Nerve. 2010;41:54\u201362. https:\/\/doi.org\/10.1002\/mus.21427.","journal-title":"Muscle Nerve"},{"issue":"10","key":"1857_CR55","doi-asserted-by":"publisher","first-page":"1380","DOI":"10.1053\/apmr.2001.25910","volume":"82","author":"PH Peckham","year":"2001","unstructured":"Peckham PH, Keith MW, Kilgore KL, Grill JH, Wuolle KS, Thrope GB, et al. Efficacy of an implanted neuroprosthesis for restoring hand grasp in tetraplegia: a multicenter study. Arch Phys Med Rehabil. 2001;82(10):1380\u20138. https:\/\/doi.org\/10.1053\/apmr.2001.25910.","journal-title":"Arch Phys Med Rehabil"},{"issue":"2","key":"1857_CR56","doi-asserted-by":"publisher","first-page":"265","DOI":"10.1053\/jhsu.2002.30919","volume":"27","author":"PH Peckham","year":"2002","unstructured":"Peckham PH, Kilgore KL, Keith MW, Bryden AM, Bhadra N, Montague FW. An advanced neuroprosthesis for restoration of hand and upper arm control using an implantable controller. J Hand Surg Am. 2002;27(2):265\u201376. https:\/\/doi.org\/10.1053\/jhsu.2002.30919.","journal-title":"J Hand Surg Am"},{"key":"1857_CR57","doi-asserted-by":"publisher","first-page":"602","DOI":"10.1109\/TBME.2013.2245128","volume":"60","author":"PH Peckham","year":"2013","unstructured":"Peckham PH, Kilgore KL. Challenges and opportunities in restoring function after paralysis. IEEE Trans Biomed Eng. 2013;60:602\u20139.","journal-title":"IEEE Trans Biomed Eng"},{"issue":"1","key":"1857_CR58","doi-asserted-by":"publisher","first-page":"76","DOI":"10.1109\/TNSRE.2007.891383","volume":"15","author":"KH Polasek","year":"2007","unstructured":"Polasek KH, Hoyen HA, Keith MW, Tyler DJ. Human nerve stimulation thresholds and selectivity using a multi-contact nerve cuff electrode. IEEE Trans Neural Syst Rehabil Eng. 2007;15(1):76\u201382.","journal-title":"IEEE Trans Neural Syst Rehabil Eng"},{"issue":"5","key":"1857_CR59","doi-asserted-by":"publisher","first-page":"428","DOI":"10.1109\/TNSRE.2009.2032603","volume":"17","author":"KH Polasek","year":"2009","unstructured":"Polasek KH, Hoyen HA, Keith MW, Kirsch RF, Tyler DJ. Stimulation stability and selectivity of chronically implanted multicontact nerve cuff electrodes in the human upper extremity. IEEE Trans Neural Syst Rehabil Eng. 2009;17(5):428\u201337. https:\/\/doi.org\/10.1109\/TNSRE.2009.2032603.","journal-title":"IEEE Trans Neural Syst Rehabil Eng"},{"issue":"6","key":"1857_CR60","doi-asserted-by":"publisher","first-page":"443","DOI":"10.1016\/0141-5425(93)90056-5","volume":"15","author":"E Rabischong","year":"1993","unstructured":"Rabischong E, Guiraud D. Determination of fatigue in the electrically stimulated quadriceps muscle and relative effect of ischaemia. J Biomed Eng. 1993;15(6):443\u201350. https:\/\/doi.org\/10.1016\/0141-5425(93)90056-5.","journal-title":"J Biomed Eng"},{"issue":"8","key":"1857_CR61","doi-asserted-by":"publisher","first-page":"1548","DOI":"10.1089\/neu.2011.2226","volume":"29","author":"LA Simpson","year":"2012","unstructured":"Simpson LA, Eng JJ, Hsieh JT, Wolfe DL, Spinal Cord Injury Rehabilitation Evidence Scire Research Team. The health and life priorities of individuals with spinal cord injury: a systematic review. J Neurotrauma. 2012;29(8):1548\u201355. https:\/\/doi.org\/10.1089\/neu.2011.2226.","journal-title":"J Neurotrauma"},{"issue":"3","key":"1857_CR62","doi-asserted-by":"publisher","first-page":"228","DOI":"10.1038\/sj.sc.3102110","volume":"46","author":"GJ Snoek","year":"2008","unstructured":"Snoek GJ, van Til JA, Krabbe PF, Ijzerman MJ. Decision for reconstructive interventions of the upper limb in individuals with tetraplegia: the effect of treatment characteristics. Spinal Cord. 2008;46(3):228\u201333. https:\/\/doi.org\/10.1038\/sj.sc.3102110.","journal-title":"Spinal Cord"},{"issue":"9","key":"1857_CR63","doi-asserted-by":"publisher","first-page":"526","DOI":"10.1038\/sj.sc.3101638","volume":"42","author":"GJ Snoek","year":"2004","unstructured":"Snoek GJ, IJzerman MJ, Hermens HJ, Maxwell D, Biering-Sorensen F. Survey of the needs of patients with spinal cord injury: impact and priority for improvement in hand function in tetraplegics. Spinal Cord. 2004;42(9):526\u201332. https:\/\/doi.org\/10.1038\/sj.sc.3101638.","journal-title":"Spinal Cord"},{"issue":"2","key":"1857_CR64","doi-asserted-by":"publisher","first-page":"167","DOI":"10.3109\/02844319509034334","volume":"29","author":"C Sollerman","year":"1995","unstructured":"Sollerman C, Ejesk\u00e4r A. Sollerman hand function test. A standardised method and its use in tetraplegic patients. Scand J Plast Reconstr Surg Hand Surg. 1995;29(2):167\u201376. https:\/\/doi.org\/10.3109\/02844319509034334.","journal-title":"Scand J Plast Reconstr Surg Hand Surg"},{"issue":"2","key":"1857_CR65","doi-asserted-by":"publisher","DOI":"10.1088\/1741-2560\/12\/2\/026002","volume":"12","author":"DW Tan","year":"2015","unstructured":"Tan DW, Schiefer MA, Keith MW, Anderson JR, Tyler DJ. Stability and selectivity of a chronic, multi-contact cuff electrode for sensory stimulation in human amputees. J Neural Eng. 2015;12(2):026002. https:\/\/doi.org\/10.1088\/1741-2560\/12\/2\/026002.","journal-title":"J Neural Eng"},{"issue":"2","key":"1857_CR66","doi-asserted-by":"publisher","first-page":"291","DOI":"10.1109\/TNSRE.2016.2609478","volume":"26","author":"W Tigra","year":"2018","unstructured":"Tigra W, Navarro B, Cherubini A, Gorron X, Gelis A, Fattal C, et al. A novel EMG interface for individuals with tetraplegia to pilot robot hand grasping. IEEE Trans Neural Syst Rehabil Eng. 2018;26(2):291\u20138. https:\/\/doi.org\/10.1109\/TNSRE.2016.2609478.","journal-title":"IEEE Trans Neural Syst Rehabil Eng"},{"issue":"1","key":"1857_CR67","doi-asserted-by":"publisher","DOI":"10.1186\/s12984-020-00676-4","volume":"17","author":"W Tigra","year":"2020","unstructured":"Tigra W, Dali M, William L, Fattal C, G\u00e9lis A, Divoux JL, et al. Selective neural electrical stimulation restores hand and forearm movements in individuals with complete tetraplegia. J Neuroeng Rehabil. 2020;17(1):66. https:\/\/doi.org\/10.1186\/s12984-020-00676-4.","journal-title":"J Neuroeng Rehabil"},{"key":"1857_CR68","volume-title":"Converging clinical and engineering research on neurorehabilitation V","author":"C Trotobas","year":"2024","unstructured":"Trotobas C, Ferreira Martins FM, Bonfim JPF, Azevedo-Coste C. A feasibility study of a hybrid approach using FES and a mechanical orthosis to restore hand movements in individuals with tetraplegia. In: Converging clinical and engineering research on neurorehabilitation V. Cham: Springer; 2024."},{"issue":"9","key":"1857_CR69","doi-asserted-by":"publisher","first-page":"539","DOI":"10.1038\/s41393-024-01018-0","volume":"62","author":"S Ullah","year":"2024","unstructured":"Ullah S, Qureshi AZ, AlWehaibi TA, Rathore FA, Sami W, Ayaz SB, et al. Functional priorities of individuals with spinal cord injury: a Saudi Arabian perspective. Spinal Cord. 2024;62(9):539\u201345. https:\/\/doi.org\/10.1038\/s41393-024-01018-0.","journal-title":"Spinal Cord"},{"issue":"6 Suppl","key":"1857_CR70","doi-asserted-by":"publisher","first-page":"S117","DOI":"10.1016\/j.apmr.2015.09.025","volume":"97","author":"J Wangdell","year":"2016","unstructured":"Wangdell J, Bunketorp-K\u00e4ll L, Koch-Borner S, Frid\u00e9n J. Early active rehabilitation after grip reconstructive surgery in tetraplegia. Arch Phys Med Rehabil. 2016;97(6 Suppl):S117\u201325.","journal-title":"Arch Phys Med Rehabil"},{"key":"1857_CR71","doi-asserted-by":"publisher","first-page":"206","DOI":"10.1016\/S0003-9993(99)90123-5","volume":"80","author":"KS Wuolle","year":"1999","unstructured":"Wuolle KS, Van Doren CL, Bryden AM, Peckham PH, Keith M, Kilgore KL, et al. Satisfaction with and usage of a hand neuroprosthesis. Arch Phys Med Rehabil. 1999;80:206\u201313.","journal-title":"Arch Phys Med Rehabil"},{"issue":"5","key":"1857_CR72","doi-asserted-by":"publisher","first-page":"816","DOI":"10.1109\/TMECH.2011.2160809","volume":"16","author":"DJ Zhang","year":"2011","unstructured":"Zhang DJ, Hayashibe M, Fraisse P, Guiraud D. FES-induced torque prediction with evoked EMG sensing for muscle fatigue tracking. IEEE\/ASME Trans Mechatron. 2011;16(5):816\u201326. https:\/\/doi.org\/10.1109\/TMECH.2011.2160809.","journal-title":"IEEE\/ASME Trans Mechatron"}],"container-title":["Journal of NeuroEngineering and Rehabilitation"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12984-025-01857-9","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12984-025-01857-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12984-025-01857-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,2]],"date-time":"2026-04-02T07:28:44Z","timestamp":1775114924000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s12984-025-01857-9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,1,14]]},"references-count":72,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["1857"],"URL":"https:\/\/doi.org\/10.1186\/s12984-025-01857-9","relation":{},"ISSN":["1743-0003"],"issn-type":[{"value":"1743-0003","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,1,14]]},"assertion":[{"value":"13 October 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"17 December 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"14 January 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The protocol was approved by the French Ethics Committee (CPP Ouest IV Nantes, France, ID-RCB #2019-A00808-49, CPP Ouest II Angers, France ID-RCB 2022-A00205-38) and French Health Agency (ANSM). The study was registered on ClinicalTrials.gov, registration numbers: NCT04306328 and NCT05555914.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Consent for publication was given by all participants.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"David Guiraud and David Andreu are shareholders of Neurinnov company.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"111"}}