{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,9]],"date-time":"2026-07-09T09:18:47Z","timestamp":1783588727198,"version":"3.55.0"},"reference-count":62,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,6,23]],"date-time":"2026-06-23T00:00:00Z","timestamp":1782172800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,7,9]],"date-time":"2026-07-09T00:00:00Z","timestamp":1783555200000},"content-version":"vor","delay-in-days":16,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J NeuroEngineering Rehabil"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Gait impairment is a hallmark symptom of Parkinson\u2019s Disease (PD). Traditional clinical assessments cannot capture real-world motor fluctuations, as they are sparsely performed. We validated the use of nearables, passive sensing technologies, including Kinect RGB-D cameras and ultra-wideband (UWB) radar, for continuous, objective assessment of gait fluctuations in PD within a home-like setting.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>Fifteen PD patients with mild symptoms and fourteen age- and sex-matched healthy controls (HC) performed 4-metre walking tasks in a living lab facility. Patients repeated the task during \u201cON\u201d and \u201cOFF\u201d states of their daily medication cycle. Gait features, including stride length, stride time, and gait speed, were extracted from Kinect, radar, and a ground-truth smart floor. Data were analysed to assess inter-sensor agreements and group-level differences.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      Stride time demonstrated the highest agreement between devices (\n                      <jats:italic>r<\/jats:italic>\n                      \u2009=\u20090.903), while stride length was weaker (\n                      <jats:italic>r<\/jats:italic>\n                      \u2009=\u20090.779). Nevertheless, stride length from both Kinect and radar distinguished PD OFF from HC (camera\n                      <jats:italic>q<\/jats:italic>\n                      \u2009=\u20090.020; radar\n                      <jats:italic>q<\/jats:italic>\n                      \u2009=\u20090.005), and radar additionally differentiated ON from OFF (\n                      <jats:italic>q<\/jats:italic>\n                      \u2009=\u20090.020). Neither device differentiated PD ON from HC, indicating medication reduced observable gait differences.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>Although some spatial metrics show device discrepancies, both systems demonstrate sensitivity to gait patterns and medication-dependent changes, supporting their use for longitudinal, real-world monitoring of motor symptoms.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s12984-026-02068-6","type":"journal-article","created":{"date-parts":[[2026,6,23]],"date-time":"2026-06-23T09:36:10Z","timestamp":1782207370000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Passive sensing of gait and medication-related fluctuations in Parkinson\u2019s disease"],"prefix":"10.1186","volume":"23","author":[{"given":"Juyoung Jenna","family":"Yun","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Charalambos","family":"Hadjipanayi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Arya","family":"Jahangiri","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alan","family":"Bannon","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Timothy G.","family":"Constandinou","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2213-6585","authenticated-orcid":false,"given":"Shlomi","family":"Haar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,6,23]]},"reference":[{"key":"2068_CR1","doi-asserted-by":"publisher","first-page":"697","DOI":"10.1016\/S1474-4422(19)30044-4","volume":"18","author":"A Mirelman","year":"2019","unstructured":"Mirelman A, et al. Gait impairments in Parkinson\u2019s disease. Lancet Neurol. 2019;18:697\u2013708.","journal-title":"Lancet Neurol"},{"key":"2068_CR2","doi-asserted-by":"publisher","first-page":"3310","DOI":"10.1007\/s00415-022-11031-z","volume":"269","author":"JYY Kwok","year":"2022","unstructured":"Kwok JYY, et al. Managing freezing of gait in Parkinson\u2019s disease: a systematic review and network meta-analysis. J Neurol. 2022;269:3310\u201324.","journal-title":"J Neurol"},{"key":"2068_CR3","doi-asserted-by":"publisher","first-page":"364","DOI":"10.1016\/j.gerinurse.2014.05.001","volume":"35","author":"T Gazibara","year":"2014","unstructured":"Gazibara T, et al. Circumstances of falls and fall-related injuries among patients with Parkinson\u2019s disease in an outpatient setting. Geriatr Nur (Lond). 2014;35:364\u20139.","journal-title":"Geriatr Nur (Lond)"},{"key":"2068_CR4","doi-asserted-by":"publisher","first-page":"2216","DOI":"10.3390\/ijerph16122216","volume":"16","author":"PHS Pelicioni","year":"2019","unstructured":"Pelicioni PHS, Menant JC, Latt MD, Lord SR. Falls in Parkinson\u2019s Disease Subtypes: Risk Factors, Locations and Circumstances. Int J Environ Res Public Health. 2019;16:2216.","journal-title":"Int J Environ Res Public Health"},{"key":"2068_CR5","doi-asserted-by":"publisher","first-page":"51","DOI":"10.1038\/s41531-025-00897-1","volume":"11","author":"M Mancini","year":"2025","unstructured":"Mancini M, et al. Digital gait biomarkers in Parkinson\u2019s disease: susceptibility\/risk, progression, response to exercise, and prognosis. Npj Park Dis. 2025;11:51.","journal-title":"Npj Park Dis"},{"key":"2068_CR6","doi-asserted-by":"publisher","first-page":"360","DOI":"10.3390\/bioengineering13030360","volume":"13","author":"M Choi","year":"2026","unstructured":"Choi M, Jo J, Jeong J. Digital Gait Biomarkers for Parkinson\u2019s Disease: Subject-Wise Validated Explainable AI Framework Using Vertical Ground Reaction Force Signals. Bioengineering. 2026;13:360.","journal-title":"Bioengineering"},{"key":"2068_CR7","doi-asserted-by":"publisher","first-page":"S11","DOI":"10.1002\/mds.20458","volume":"20","author":"J Jankovic","year":"2005","unstructured":"Jankovic J. Motor fluctuations and dyskinesias in Parkinson\u2019s disease: Clinical manifestations. Mov Disord. 2005;20:S11\u20136.","journal-title":"Mov Disord"},{"key":"2068_CR8","doi-asserted-by":"publisher","first-page":"1707","DOI":"10.1002\/mds.22197","volume":"23","author":"CA Haaxma","year":"2008","unstructured":"Haaxma CA, Bloem BR, Borm GF, Horstink MW. I. M. Comparison of a timed motor test battery to the Unified Parkinson\u2019s Disease Rating Scale-III in Parkinson\u2019s disease. Mov Disord. 2008;23:1707\u201317.","journal-title":"Mov Disord"},{"key":"2068_CR9","doi-asserted-by":"publisher","first-page":"6","DOI":"10.1038\/s41746-019-0214-x","volume":"3","author":"MK Erb","year":"2020","unstructured":"Erb MK, et al. mHealth and wearable technology should replace motor diaries to track motor fluctuations in Parkinson\u2019s disease. Npj Digit Med. 2020;3:6.","journal-title":"Npj Digit Med"},{"key":"2068_CR10","doi-asserted-by":"publisher","first-page":"1079","DOI":"10.1002\/mds.20101","volume":"19","author":"LV Metman","year":"2004","unstructured":"Metman LV, et al. Test\u2013retest reliability of UPDRS-III, dyskinesia scales, and timed motor tests in patients with advanced Parkinson\u2019s disease: An argument against multiple baseline assessments. Mov Disord. 2004;19:1079\u201384.","journal-title":"Mov Disord"},{"key":"2068_CR11","doi-asserted-by":"publisher","first-page":"110665","DOI":"10.1016\/j.jbiomech.2021.110665","volume":"127","author":"RM Kanko","year":"2021","unstructured":"Kanko RM, Laende EK, Davis EM, Selbie WS, Deluzio KJ. Concurrent assessment of gait kinematics using marker-based and markerless motion capture. J Biomech. 2021;127:110665.","journal-title":"J Biomech"},{"key":"2068_CR12","doi-asserted-by":"publisher","first-page":"22880","DOI":"10.1038\/s41598-023-49360-2","volume":"13","author":"K Das","year":"2023","unstructured":"Das K, de Paula Oliveira T, Newell J. Comparison of markerless and marker-based motion capture systems using 95% functional limits of agreement in a linear mixed-effects modelling framework. Sci Rep. 2023;13:22880.","journal-title":"Sci Rep"},{"key":"2068_CR13","doi-asserted-by":"publisher","first-page":"825","DOI":"10.3390\/s17040825","volume":"17","author":"C Tunca","year":"2017","unstructured":"Tunca C, et al. Inertial Sensor-Based Robust Gait Analysis in Non-Hospital Settings for Neurological Disorders. Sensors. 2017;17:825.","journal-title":"Sensors"},{"key":"2068_CR14","doi-asserted-by":"publisher","first-page":"1521","DOI":"10.1109\/JBHI.2016.2608720","volume":"20","author":"S Chen","year":"2016","unstructured":"Chen S, Lach J, Lo B, Yang G-Z. Toward Pervasive Gait Analysis With Wearable Sensors: A Systematic Review. IEEE J Biomed Health Inf. 2016;20:1521\u201337.","journal-title":"IEEE J Biomed Health Inf"},{"key":"2068_CR15","doi-asserted-by":"publisher","first-page":"11","DOI":"10.1016\/j.gaitpost.2014.03.189","volume":"40","author":"PB Shull","year":"2014","unstructured":"Shull PB, Jirattigalachote W, Hunt MA, Cutkosky MR, Delp SL. Quantified self and human movement: A review on the clinical impact of wearable sensing and feedback for gait analysis and intervention. Gait Posture. 2014;40:11\u20139.","journal-title":"Gait Posture"},{"key":"2068_CR16","first-page":"2255","volume":"12","author":"W Tao","year":"2012","unstructured":"Tao W, Liu T, Zheng R, Feng H. Gait Anal Using Wearable Sens Sens. 2012;12:2255\u201383.","journal-title":"Gait Anal Using Wearable Sens Sens"},{"key":"2068_CR17","doi-asserted-by":"publisher","first-page":"150","DOI":"10.1109\/MeMeA.2015.7145189","volume":"146","author":"V Agostini","year":"2015","unstructured":"Agostini V, et al. Wearable sensors for gait analysis. 2015 IEEE Int Symp Med Measurements Appl (MeMeA) Proc. 2015;146:150. https:\/\/doi.org\/10.1109\/MeMeA.2015.7145189.","journal-title":"2015 IEEE Int Symp Med Measurements Appl (MeMeA) Proc"},{"key":"2068_CR18","doi-asserted-by":"publisher","unstructured":"Johnston AH, Weiss GM. Smartwatch-based biometric gait recognition. in 2015 IEEE 7th International Conference on Biometrics Theory, Applications and Systems (BTAS). 2015;1\u20136. https:\/\/doi.org\/10.1109\/BTAS.2015.7358794.","DOI":"10.1109\/BTAS.2015.7358794"},{"key":"2068_CR19","doi-asserted-by":"publisher","first-page":"133","DOI":"10.1159\/000503282","volume":"3","author":"D Psaltos","year":"2019","unstructured":"Psaltos D, et al. Multimodal Wearable Sensors to Measure Gait and Voice. Digit Biomark. 2019;3:133\u201344.","journal-title":"Digit Biomark"},{"key":"2068_CR20","doi-asserted-by":"publisher","first-page":"2504","DOI":"10.1007\/s10439-023-03290-2","volume":"51","author":"CA Bailey","year":"2023","unstructured":"Bailey CA, Mir-Orefice A, Uchida TK, Nantel J, Graham RB. Smartwatch-Based Prediction of Single-Stride and Stride-to-Stride Gait Outcomes Using Regression-Based Machine Learning. Ann Biomed Eng. 2023;51:2504\u201317.","journal-title":"Ann Biomed Eng"},{"key":"2068_CR21","doi-asserted-by":"publisher","first-page":"67","DOI":"10.1186\/s12984-021-00863-x","volume":"18","author":"DM Peters","year":"2021","unstructured":"Peters DM, et al. Utilization of wearable technology to assess gait and mobility post-stroke: a systematic review. J Neuroeng Rehabil. 2021;18:67.","journal-title":"J Neuroeng Rehabil"},{"key":"2068_CR22","doi-asserted-by":"publisher","unstructured":"Jovanov E. Preliminary analysis of the use of smartwatches for longitudinal health monitoring. 2015 37th Annual Int Conf IEEE Eng Med Biology Soc (EMBC). 2015;865\u2013868. https:\/\/doi.org\/10.1109\/EMBC.2015.7318499.","DOI":"10.1109\/EMBC.2015.7318499"},{"key":"2068_CR23","doi-asserted-by":"publisher","unstructured":"Nemati E, Suh YS, Motamed B, Sarrafzadeh M. Gait velocity estimation for a smartwatch platform using Kalman filter peak recovery. in 2016 IEEE 13th International Conference on Wearable and Implantable Body Sensor Networks (BSN). 2016;230\u2013235. https:\/\/doi.org\/10.1109\/BSN.2016.7516265.","DOI":"10.1109\/BSN.2016.7516265"},{"key":"2068_CR24","doi-asserted-by":"publisher","first-page":"1754","DOI":"10.1038\/s41598-024-51766-5","volume":"14","author":"C Kirk","year":"2024","unstructured":"Kirk C, et al. Mobilise-D insights to estimate real-world walking speed in multiple conditions with a wearable device. Sci Rep. 2024;14:1754.","journal-title":"Sci Rep"},{"key":"2068_CR25","doi-asserted-by":"publisher","first-page":"169","DOI":"10.1038\/s41746-024-01163-z","volume":"7","author":"W Zhang","year":"2024","unstructured":"Zhang W, et al. Wearable sensor-based quantitative gait analysis in Parkinson\u2019s disease patients with different motor subtypes. Npj Digit Med. 2024;7:169.","journal-title":"Npj Digit Med"},{"key":"2068_CR26","doi-asserted-by":"publisher","first-page":"1219","DOI":"10.1016\/j.jbiomech.2015.01.036","volume":"48","author":"SJ Howarth","year":"2015","unstructured":"Howarth SJ, Graham RB. Sensor positioning and experimental constraints influence estimates of local dynamic stability during repetitive spine movements. J Biomech. 2015;48:1219\u201323.","journal-title":"J Biomech"},{"key":"2068_CR27","doi-asserted-by":"publisher","first-page":"50","DOI":"10.1159\/000511611","volume":"4","author":"M Tietsch","year":"2020","unstructured":"Tietsch M, et al. Robust Step Detection from Different Waist-Worn Sensor Positions: Implications for Clinical Studies. Digit Biomark. 2020;4:50\u20138.","journal-title":"Digit Biomark"},{"key":"2068_CR28","doi-asserted-by":"publisher","first-page":"5945","DOI":"10.3390\/s21175945","volume":"21","author":"C Ferraris","year":"2021","unstructured":"Ferraris C, et al. Monitoring of Gait Parameters in Post-Stroke Individuals: A Feasibility Study Using RGB-D Sensors. Sensors. 2021;21:5945.","journal-title":"Sensors"},{"key":"2068_CR29","doi-asserted-by":"publisher","first-page":"1129","DOI":"10.3390\/s19051129","volume":"19","author":"C Ferraris","year":"2019","unstructured":"Ferraris C, et al. Feasibility of Home-Based Automated Assessment of Postural Instability and Lower Limb Impairments in Parkinson\u2019s Disease. Sensors. 2019;19:1129.","journal-title":"Sensors"},{"key":"2068_CR30","doi-asserted-by":"publisher","unstructured":"Gabel M, Gilad-Bachrach R, Renshaw E, Schuster A. Full body gait analysis with Kinect. 2012 Annual Int Conf IEEE Eng Med Biology Soc. 2012;1964\u20131967. https:\/\/doi.org\/10.1109\/EMBC.2012.6346340.","DOI":"10.1109\/EMBC.2012.6346340"},{"key":"2068_CR31","doi-asserted-by":"publisher","first-page":"274","DOI":"10.3109\/03091902.2014.909540","volume":"38","author":"A Pfister","year":"2014","unstructured":"Pfister A, West AM, Bronner S, Noah JA. Comparative abilities of Microsoft Kinect and Vicon 3D motion capture for gait analysis. J Med Eng Technol. 2014;38:274\u201380.","journal-title":"J Med Eng Technol"},{"key":"2068_CR32","doi-asserted-by":"publisher","unstructured":"Liu Z, He C, Zhang F, Ge J. Vision-Based Gait Analysis Method in Parkinson\u2019s Disease. in 2024 4th International Conference on Computer Science, Electronic Information Engineering and Intelligent Control Technology (CEI). 2024;139\u2013143. https:\/\/doi.org\/10.1109\/CEI63587.2024.10871802","DOI":"10.1109\/CEI63587.2024.10871802"},{"key":"2068_CR33","doi-asserted-by":"publisher","first-page":"824","DOI":"10.3390\/s22030824","volume":"22","author":"V Cimolin","year":"2022","unstructured":"Cimolin V, et al. Computation of Gait Parameters in Post Stroke and Parkinson\u2019s Disease: A Comparative Study Using RGB-D Sensors and Optoelectronic Systems. Sensors. 2022;22:824.","journal-title":"Sensors"},{"key":"2068_CR34","doi-asserted-by":"publisher","first-page":"5483","DOI":"10.1007\/s11263-025-02438-y","volume":"133","author":"S Li","year":"2025","unstructured":"Li S, et al. RGB-D Visual Perception for Occluded Scenes via Event Camera. Int J Comput Vis. 2025;133:5483\u2013504.","journal-title":"Int J Comput Vis"},{"key":"2068_CR35","doi-asserted-by":"publisher","first-page":"194","DOI":"10.3390\/s16020194","volume":"16","author":"S Springer","year":"2016","unstructured":"Springer S, Yogev Seligmann G. Validity of the Kinect for Gait Assessment: A Focused Review. Sensors. 2016;16:194.","journal-title":"Sensors"},{"key":"2068_CR36","doi-asserted-by":"publisher","unstructured":"Jeyasingh-Jacob J, Crook-Rumsey M, Shah H, et al. Markerless motion capture to quantify functional performance in neurodegeneration: systematic review. JMIR Aging. 2024;7:e52582. https:\/\/doi.org\/10.2196\/52582","DOI":"10.2196\/52582"},{"key":"2068_CR37","doi-asserted-by":"crossref","unstructured":"Ocimum Scientific Publishers Pty Ltd. Radar Technology as a Mechanism for Clinical Gait Analysis: A Review. J. Ann. Bioeng. 2021.","DOI":"10.33513\/BIOE\/2001-12"},{"key":"2068_CR38","doi-asserted-by":"publisher","first-page":"2629","DOI":"10.1109\/TBME.2019.2893528","volume":"66","author":"A-K Seifert","year":"2019","unstructured":"Seifert A-K, Amin MG, Zoubir AM. Toward Unobtrusive In-Home Gait Analysis Based on Radar Micro-Doppler Signatures. IEEE Trans Biomed Eng. 2019;66:2629\u201340.","journal-title":"IEEE Trans Biomed Eng"},{"key":"2068_CR39","doi-asserted-by":"publisher","first-page":"eadc9669","DOI":"10.1126\/scitranslmed.adc9669","volume":"14","author":"Y Liu","year":"2022","unstructured":"Liu Y, et al. Monitoring gait at home with radio waves in Parkinson\u2019s disease: A marker of severity, progression, and medication response. Sci Transl Med. 2022;14:eadc9669.","journal-title":"Sci Transl Med"},{"key":"2068_CR40","doi-asserted-by":"publisher","unstructured":"L\u00f3pez-Delgado IE, Navarro-L\u00f3pez V, Grandas-P\u00e9rez F, Godino-Llorente JI, Grajal J. Radar Network for Gait Monitoring: Technology and Validation. IEEE Trans Biomed Eng. 2025;1\u201311. https:\/\/doi.org\/10.1109\/TBME.2025.3583785.","DOI":"10.1109\/TBME.2025.3583785"},{"key":"2068_CR41","doi-asserted-by":"publisher","first-page":"2854","DOI":"10.1109\/TBME.2024.3396650","volume":"71","author":"C Hadjipanayi","year":"2024","unstructured":"Hadjipanayi C, et al. Remote Gait Analysis Using Ultra-Wideband Radar Technology Based on Joint Range-Doppler-Time Representation. IEEE Trans Biomed Eng. 2024;71:2854\u201365.","journal-title":"IEEE Trans Biomed Eng"},{"key":"2068_CR42","doi-asserted-by":"publisher","first-page":"e072094","DOI":"10.1136\/bmjopen-2023-072094","volume":"13","author":"M Crook-Rumsey","year":"2023","unstructured":"Crook-Rumsey M, et al. Multicohort cross-sectional study of cognitive and behavioural digital biomarkers in neurodegeneration: the Living Lab Study protocol. BMJ Open. 2023;13:e072094.","journal-title":"BMJ Open"},{"key":"2068_CR43","unstructured":"Overview. | Devices for remote monitoring of Parkinson\u2019s disease | Guidance | NICE.2023. https:\/\/www.nice.org.uk\/guidance\/dg51."},{"key":"2068_CR44","doi-asserted-by":"publisher","first-page":"1111260","DOI":"10.3389\/fneur.2023.1111260","volume":"14","author":"H Debelle","year":"2023","unstructured":"Debelle H, et al. Feasibility and usability of a digital health technology system to monitor mobility and assess medication adherence in mild-to-moderate Parkinson\u2019s disease. Front Neurol. 2023;14:1111260.","journal-title":"Front Neurol"},{"key":"2068_CR45","doi-asserted-by":"publisher","first-page":"138","DOI":"10.1186\/s12984-021-00931-2","volume":"18","author":"A Keogh","year":"2021","unstructured":"Keogh A, Argent R, Anderson A, Caulfield B, Johnston W. Assessing the usability of wearable devices to measure gait and physical activity in chronic conditions: a systematic review. J Neuroeng Rehabil. 2021;18:138.","journal-title":"J Neuroeng Rehabil"},{"key":"2068_CR46","doi-asserted-by":"publisher","first-page":"7680","DOI":"10.3390\/s21227680","volume":"21","author":"V Jakob","year":"2021","unstructured":"Jakob V, et al. Validation of a Sensor-Based Gait Analysis System with a Gold-Standard Motion Capture System in Patients with Parkinson\u2019s Disease. Sensors. 2021;21:7680.","journal-title":"Sensors"},{"key":"2068_CR47","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s12984-020-00774-3","volume":"18","author":"M Mancini","year":"2021","unstructured":"Mancini M, et al. Measuring freezing of gait during daily-life: an open-source, wearable sensors approach. J Neuroeng Rehabil. 2021;18:1.","journal-title":"J Neuroeng Rehabil"},{"key":"2068_CR48","doi-asserted-by":"publisher","first-page":"28","DOI":"10.11138\/FNeur\/2017.32.1.028","volume":"32","author":"M Pistacchi","year":"2017","unstructured":"Pistacchi M, et al. Gait analysis and clinical correlations in early Parkinson\u2019s disease. Funct Neurol. 2017;32:28\u201334.","journal-title":"Funct Neurol"},{"key":"2068_CR49","doi-asserted-by":"publisher","first-page":"752","DOI":"10.1038\/s41598-020-80768-2","volume":"11","author":"APJ Zanardi","year":"2021","unstructured":"Zanardi APJ, et al. Gait parameters of Parkinson\u2019s disease compared with healthy controls: a systematic review and meta-analysis. Sci Rep. 2021;11:752.","journal-title":"Sci Rep"},{"key":"2068_CR50","doi-asserted-by":"publisher","first-page":"2037","DOI":"10.1093\/brain\/awz141","volume":"142","author":"NG Pozzi","year":"2019","unstructured":"Pozzi NG, et al. Freezing of gait in Parkinson\u2019s disease reflects a sudden derangement of locomotor network dynamics. Brain J Neurol. 2019;142:2037\u201350.","journal-title":"Brain J Neurol"},{"key":"2068_CR51","doi-asserted-by":"publisher","first-page":"3906","DOI":"10.1093\/brain\/awz325","volume":"142","author":"MJ Georgiades","year":"2019","unstructured":"Georgiades MJ, et al. Hitting the brakes: pathological subthalamic nucleus activity in Parkinson\u2019s disease gait freezing. Brain J Neurol. 2019;142:3906\u201316.","journal-title":"Brain J Neurol"},{"key":"2068_CR52","doi-asserted-by":"publisher","first-page":"1472","DOI":"10.1152\/jn.00964.2016","volume":"118","author":"WJ Lipski","year":"2017","unstructured":"Lipski WJ, et al. Dynamics of human subthalamic neuron phase-locking to motor and sensory cortical oscillations during movement. J Neurophysiol. 2017;118:1472\u201387.","journal-title":"J Neurophysiol"},{"key":"2068_CR53","doi-asserted-by":"publisher","first-page":"1404613","DOI":"10.3389\/fnins.2024.1404613","volume":"18","author":"P-H Lin","year":"2024","unstructured":"Lin P-H, et al. Investigating spatiotemporal and kinematic gait parameters in individuals with Parkinson\u2019s disease with a history of freezing of gait and exploring the effects of dopaminergic therapy on freezing of gait subtypes. Front Neurosci. 2024;18:1404613.","journal-title":"Front Neurosci"},{"key":"2068_CR54","doi-asserted-by":"publisher","first-page":"34","DOI":"10.1016\/S0966-6362(00)00070-9","volume":"12","author":"H Sadeghi","year":"2000","unstructured":"Sadeghi H, Allard P, Prince F, Labelle H. Symmetry and limb dominance in able-bodied gait: a review. Gait Posture. 2000;12:34\u201345.","journal-title":"Gait Posture"},{"key":"2068_CR55","doi-asserted-by":"publisher","first-page":"1815","DOI":"10.1111\/j.1460-9568.2006.05033.x","volume":"24","author":"R Baltadjieva","year":"2006","unstructured":"Baltadjieva R, Giladi N, Gruendlinger L, Peretz C, Hausdorff JM. Marked alterations in the gait timing and rhythmicity of patients with de novo Parkinson\u2019s disease. Eur J Neurosci. 2006;24:1815\u201320.","journal-title":"Eur J Neurosci"},{"key":"2068_CR56","doi-asserted-by":"publisher","first-page":"1129","DOI":"10.3390\/neurolint15030070","volume":"15","author":"E Giannakou","year":"2023","unstructured":"Giannakou E, Fotiadou S, Gourgoulis V, Mavrommatis G, Aggelousis N. A Comparative Analysis of Symmetry Indices for Spatiotemporal Gait Features in Early Parkinson\u2019s Disease. Neurol Int. 2023;15:1129\u201339.","journal-title":"Neurol Int"},{"key":"2068_CR57","doi-asserted-by":"crossref","unstructured":"Lai E et al. Risk of Falls in Parkinson\u2019s Disease after Deep Brain Stimulation. Neurology. 2013;80: P04.184-P04.184.","DOI":"10.1212\/WNL.80.7_supplement.P04.184"},{"key":"2068_CR58","doi-asserted-by":"publisher","first-page":"844","DOI":"10.1002\/mds.23583","volume":"26","author":"A Fasano","year":"2011","unstructured":"Fasano A, et al. Modulation of gait coordination by subthalamic stimulation improves freezing of gait. Mov Disord. 2011;26:844\u201351.","journal-title":"Mov Disord"},{"key":"2068_CR59","doi-asserted-by":"publisher","first-page":"1020","DOI":"10.1177\/15459683211041309","volume":"35","author":"DK Ravi","year":"2021","unstructured":"Ravi DK, et al. Does Subthalamic Deep Brain Stimulation Impact Asymmetry and Dyscoordination of Gait in Parkinson\u2019s Disease? Neurorehabil. Neural Repair. 2021;35:1020\u20139.","journal-title":"Neural Repair"},{"key":"2068_CR60","doi-asserted-by":"publisher","first-page":"50","DOI":"10.1016\/j.parkreldis.2014.10.026","volume":"21","author":"P Mart\u00ednez-Mart\u00edn","year":"2015","unstructured":"Mart\u00ednez-Mart\u00edn P, et al. Parkinson\u2019s disease severity levels and MDS-Unified Parkinson\u2019s Disease Rating Scale. Parkinsonism Relat Disord. 2015;21:50\u20134.","journal-title":"Parkinsonism Relat Disord"},{"key":"2068_CR61","doi-asserted-by":"publisher","unstructured":"Steinhage A, Lauterbach C. SensFloor\u00ae and NaviFloor\u00ae: Large-Area Sensor Systems beneath Your Feet. in Handbook of Research on Ambient Intelligence and Smart Environments: Trends and Perspectives 41\u201355IGI Global Scientific Publishing, 2011. https:\/\/doi.org\/10.4018\/978-1-61692-857-5.ch003","DOI":"10.4018\/978-1-61692-857-5.ch003"},{"key":"2068_CR62","doi-asserted-by":"publisher","first-page":"241","DOI":"10.1016\/j.gaitpost.2009.10.014","volume":"31","author":"KK Patterson","year":"2010","unstructured":"Patterson KK, Gage WH, Brooks D, Black SE, McIlroy WE. Evaluation of gait symmetry after stroke: A comparison of current methods and recommendations for standardization. Gait Posture. 2010;31:241\u20136.","journal-title":"Gait Posture"}],"container-title":["Journal of NeuroEngineering and Rehabilitation"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12984-026-02068-6","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12984-026-02068-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12984-026-02068-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,7,9]],"date-time":"2026-07-09T09:02:32Z","timestamp":1783587752000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s12984-026-02068-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,6,23]]},"references-count":62,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["2068"],"URL":"https:\/\/doi.org\/10.1186\/s12984-026-02068-6","relation":{},"ISSN":["1743-0003"],"issn-type":[{"value":"1743-0003","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,6,23]]},"assertion":[{"value":"17 December 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"17 June 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"23 June 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"All participants gave written informed consent before participation in the study. The study was approved by the Imperial College Research Ethics Committee (ICREC 21IC6992) and conducted in accordance with the Declaration of Helsinki.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"No images of participants are included.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"213"}}