{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,20]],"date-time":"2026-10-20T02:39:23Z","timestamp":1792463963910,"version":"4.5.0"},"reference-count":63,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,7,16]],"date-time":"2026-07-16T00:00:00Z","timestamp":1784160000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,10,20]],"date-time":"2026-10-20T00:00:00Z","timestamp":1792454400000},"content-version":"vor","delay-in-days":96,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J NeuroEngineering Rehabil"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>To ensure continuous rehabilitation for patients with hemiparesis due to brain disorders, there is a growing need for simple, accessible systems that enable unsupervised self-training. The occurrence of compensatory trunk movements during the unsupervised exercise may prevent true functional recovery. This study proposes a smartphone-based visual-auditory feedback system designed to detect and suppress compensatory trunk movements in real-time without wearable sensors.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>A pilot cohort (n\u2009=\u200916) was first used to calibrate detection thresholds for compensatory trunk movements. Subsequently, a total of 55 hemiparetic patients were enrolled in a randomized controlled trial and allocated to a Feedback (FB) group (n\u2009=\u200927) or a Non-Feedback (NFB) group (n\u2009=\u200928). Participants performed standardised upper limb rehabilitation tasks using the Rapael Smart Board\u2122, a planar upper limb rehabilitation device. The proposed system utilised a smartphone camera with MediaPipe-based pose estimation to track trunk movements and provided real-time traffic-light feedback based on calibrated thresholds. Outcome measures included trunk path length, trunk deviation, task efficiency, and spatial occupancy, which were evaluated using 3D coordinates reconstructed from depth camera data.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      The FB group demonstrated significantly improved postural stability compared to the NFB group, with a 37.9% reduction in trunk path length (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u20090.014) and a 35.3% decrease in spatial occupancy (\n                      <jats:italic>p<\/jats:italic>\n                      \u2009=\u20090.003). Kinematic analysis revealed that the NFB group's shorter hand path lengths were achieved through kinematic redundancy\u2014specifically, the recruitment of trunk degrees of freedom\u2014rather than through selective upper limb motor control. In contrast, the FB group maintained a stable posture near the neutral position, ensuring true upper limb engagement. The usability assessment demonstrated that the system was well received by users and was reliable (Cronbach's\n                      <jats:inline-formula>\n                        <jats:tex-math>$$\\alpha $$<\/jats:tex-math>\n                      <\/jats:inline-formula>\n                      = 0.775).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>The proposed system, which integrates mobile technology, effectively suppresses compensatory trunk movements and promotes selective motor control, and ensures that rehabilitation outcomes reflect true upper limb joint engagement rather than kinematic redundancy through compensatory trunk recruitment. While certain design considerations remain, particularly related to dynamic recalibration and the use of a fixed auditory feedback window, the system retains strong potential as an automated feedback solution, offering a scalable and accessible pathway for high-quality unsupervised home rehabilitation.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s12984-026-02093-5","type":"journal-article","created":{"date-parts":[[2026,7,16]],"date-time":"2026-07-16T17:56:39Z","timestamp":1784224599000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Smartphone-based real-time feedback to suppress trunk compensation for unsupervised upper limb rehabilitation in patients with brain disorders"],"prefix":"10.1186","volume":"23","author":[{"given":"Su Hyeon","family":"Kim","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Doo Na","family":"Cho","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Won Hyuk","family":"Chang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8046-6374","authenticated-orcid":false,"given":"Hyo-Chang","family":"Seo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,7,16]]},"reference":[{"key":"2093_CR1","doi-asserted-by":"publisher","DOI":"10.7189\/jogh.13.04160","volume":"13","author":"Y Huang","year":"2023","unstructured":"Huang Y, Li Y, Pan H, Han L. Global, regional, and national burden of neurological disorders in 204 countries and territories worldwide. J Glob Health. 2023;13:04160.","journal-title":"J Glob Health"},{"key":"2093_CR2","doi-asserted-by":"crossref","unstructured":"Lei J, Gillespie K. Projected global burden of brain disorders through 2050 (P7-15.001). In: Neurology: 2024: Lippincott Williams & Wilkins Hagerstown, MD; 2024:3234.","DOI":"10.1212\/WNL.0000000000205009"},{"issue":"4","key":"2093_CR3","doi-asserted-by":"publisher","first-page":"348","DOI":"10.1016\/S1474-4422(19)30415-6","volume":"19","author":"CM Stinear","year":"2020","unstructured":"Stinear CM, Lang CE, Zeiler S, Byblow WD. Advances and challenges in stroke rehabilitation. Lancet Neurol. 2020;19(4):348\u201360.","journal-title":"Lancet Neurol"},{"issue":"1","key":"2093_CR4","doi-asserted-by":"publisher","first-page":"161","DOI":"10.1111\/jgs.15101","volume":"66","author":"JK Burton","year":"2018","unstructured":"Burton JK, Ferguson EE, Barugh AJ, Walesby KE, MacLullich AM, Shenkin SD, et al. Predicting discharge to institutional long-term care after stroke: a systematic review and metaanalysis. J Am Geriatr Soc. 2018;66(1):161\u20139.","journal-title":"J Am Geriatr Soc"},{"issue":"3","key":"2093_CR5","doi-asserted-by":"publisher","first-page":"537","DOI":"10.1007\/s11060-011-0772-5","volume":"107","author":"M Bartolo","year":"2012","unstructured":"Bartolo M, Zucchella C, Pace A, Lanzetta G, Vecchione C, Bartolo M, et al. Early rehabilitation after surgery improves functional outcome in inpatients with brain tumours. J Neurooncol. 2012;107(3):537\u201344.","journal-title":"J Neurooncol"},{"issue":"1","key":"2093_CR6","doi-asserted-by":"publisher","first-page":"142","DOI":"10.2522\/ptj.20100341","volume":"92","author":"J van Kordelaar","year":"2012","unstructured":"van Kordelaar J, van Wegen EE, Nijland RH, de Groot JH, Meskers CG, Harlaar J, et al. Assessing longitudinal change in coordination of the paretic upper limb using on-site 3-dimensional kinematic measurements. Phys Ther. 2012;92(1):142\u201351.","journal-title":"Phys Ther"},{"issue":"4","key":"2093_CR7","doi-asserted-by":"publisher","first-page":"344","DOI":"10.1016\/S1474-4422(24)00038-3","volume":"23","author":"JD Steinmetz","year":"2024","unstructured":"Steinmetz JD, Seeher KM, Schiess N, Nichols E, Cao B, Servili C, et al. Global, regional, and national burden of disorders affecting the nervous system, 1990\u20132021: a systematic analysis for the Global Burden of Disease Study 2021. Lancet Neurol. 2024;23(4):344\u201381.","journal-title":"Lancet Neurol"},{"issue":"3","key":"2093_CR8","doi-asserted-by":"publisher","first-page":"277","DOI":"10.1310\/tsr1803-277","volume":"18","author":"MT Jurkiewicz","year":"2011","unstructured":"Jurkiewicz MT, Marzolini S, Oh P. Adherence to a home-based exercise program for individuals after stroke. Top Stroke Rehabil. 2011;18(3):277\u201384.","journal-title":"Top Stroke Rehabil"},{"key":"2093_CR9","doi-asserted-by":"publisher","DOI":"10.2196\/mhealth.8518","author":"R Argent","year":"2018","unstructured":"Argent R, Daly A, Caulfield B. Patient involvement with home-based exercise programs: can connected health interventions influence adherence? JMIR Mhealth Uhealth. 2018. https:\/\/doi.org\/10.2196\/mhealth.8518.","journal-title":"JMIR Mhealth Uhealth"},{"issue":"1","key":"2093_CR10","doi-asserted-by":"publisher","first-page":"71","DOI":"10.1682\/JRRD.2011.04.0074","volume":"50","author":"W Liu","year":"2013","unstructured":"Liu W, Waller SM, Kepple T, Whitall J. Compensatory arm reaching strategies after stroke: induced position analysis. J Rehabil Res Dev. 2013;50(1):71.","journal-title":"J Rehabil Res Dev"},{"issue":"4","key":"2093_CR11","doi-asserted-by":"publisher","first-page":"237","DOI":"10.1310\/tsr1604-237","volume":"16","author":"PS Lum","year":"2009","unstructured":"Lum PS, Mulroy S, Amdur RL, Requejo P, Prilutsky BI, Dromerick AW. Gains in upper extremity function after stroke via recovery or compensation: potential differential effects on amount of real-world limb use. Top Stroke Rehabil. 2009;16(4):237\u201353.","journal-title":"Top Stroke Rehabil"},{"issue":"1","key":"2093_CR12","doi-asserted-by":"publisher","first-page":"131","DOI":"10.1186\/s12984-019-0609-6","volume":"16","author":"S Cai","year":"2019","unstructured":"Cai S, Li G, Zhang X, Huang S, Zheng H, Ma K, et al. Detecting compensatory movements of stroke survivors using pressure distribution data and machine learning algorithms. J Neuroeng Rehabil. 2019;16(1):131.","journal-title":"J Neuroeng Rehabil"},{"issue":"1","key":"2093_CR13","doi-asserted-by":"publisher","first-page":"58","DOI":"10.1186\/s12984-020-00687-1","volume":"17","author":"S Cai","year":"2020","unstructured":"Cai S, Wei X, Su E, Wu W, Zheng H, Xie L. Online compensation detecting for real-time reduction of compensatory motions during reaching: a pilot study with stroke survivors. J Neuroeng Rehabil. 2020;17(1):58.","journal-title":"J Neuroeng Rehabil"},{"issue":"7","key":"2093_CR14","doi-asserted-by":"publisher","first-page":"553","DOI":"10.3109\/09638288.2014.932450","volume":"37","author":"LM Pain","year":"2015","unstructured":"Pain LM, Baker R, Richardson D, Agur AM. Effect of trunk-restraint training on function and compensatory trunk, shoulder and elbow patterns during post-stroke reach: a systematic review. Disabil Rehabil. 2015;37(7):553\u201362.","journal-title":"Disabil Rehabil"},{"key":"2093_CR15","first-page":"563","volume-title":"International handbook of occupational therapy interventions","author":"MF Levin","year":"2014","unstructured":"Levin MF. Trunk restraint: physical intervention for improvement of upper-limb motor impairment and function. In: International handbook of occupational therapy interventions. Springer; 2014. p. 563\u201372."},{"issue":"8","key":"2093_CR16","doi-asserted-by":"publisher","first-page":"820","DOI":"10.1001\/jama.2017.22036","volume":"319","author":"M Gittler","year":"2018","unstructured":"Gittler M, Davis AM. Guidelines for adult stroke rehabilitation and recovery. JAMA. 2018;319(8):820\u20131.","journal-title":"JAMA"},{"issue":"10","key":"2093_CR17","doi-asserted-by":"publisher","first-page":"1692","DOI":"10.1016\/j.apmr.2009.04.005","volume":"90","author":"CE Lang","year":"2009","unstructured":"Lang CE, MacDonald JR, Reisman DS, Boyd L, Kimberley TJ, Schindler-Ivens SM, et al. Observation of amounts of movement practice provided during stroke rehabilitation. Arch Phys Med Rehabil. 2009;90(10):1692\u20138.","journal-title":"Arch Phys Med Rehabil"},{"key":"2093_CR18","doi-asserted-by":"publisher","DOI":"10.3389\/fnagi.2023.1154795","volume":"15","author":"S Zhou","year":"2023","unstructured":"Zhou S, Zhang J, Chen F, Wong TW-L, Ng SS, Li Z, et al. Automatic theranostics for long-term neurorehabilitation after stroke. Front Aging Neurosci. 2023;15:1154795.","journal-title":"Front Aging Neurosci"},{"issue":"3","key":"2093_CR19","doi-asserted-by":"publisher","first-page":"261","DOI":"10.1016\/j.medengphy.2011.10.004","volume":"34","author":"HS Lo","year":"2012","unstructured":"Lo HS, Xie SQ. Exoskeleton robots for upper-limb rehabilitation: state of the art and future prospects. Med Eng Phys. 2012;34(3):261\u20138.","journal-title":"Med Eng Phys"},{"key":"2093_CR20","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1109\/JTEHM.2018.2829208","volume":"6","author":"SI Lee","year":"2018","unstructured":"Lee SI, Adans-Dester CP, Grimaldi M, Dowling AV, Horak PC, Black-Schaffer RM, et al. Enabling stroke rehabilitation in home and community settings: a wearable sensor-based approach for upper-limb motor training. IEEE J Transl Eng Health Med. 2018;6:1\u201311.","journal-title":"IEEE J Transl Eng Health Med"},{"key":"2093_CR21","doi-asserted-by":"publisher","first-page":"3942","DOI":"10.1109\/TNSRE.2024.3486173","volume":"32","author":"AS Knill","year":"2024","unstructured":"Knill AS, Studer B, Wolf P, Riener R, Goffredo M, Maggioni S. Kinematic assessment of upper limb movements using the armeopower robotic exoskeleton. IEEE Trans Neural Syst Rehabil Eng. 2024;32:3942\u201352.","journal-title":"IEEE Trans Neural Syst Rehabil Eng"},{"issue":"3","key":"2093_CR22","doi-asserted-by":"publisher","first-page":"327","DOI":"10.1109\/TNSRE.2007.903899","volume":"15","author":"HI Krebs","year":"2007","unstructured":"Krebs HI, Volpe BT, Williams D, Celestino J, Charles SK, Lynch D, et al. Robot-aided neurorehabilitation: a robot for wrist rehabilitation. IEEE Trans Neural Syst Rehabil Eng. 2007;15(3):327\u201335.","journal-title":"IEEE Trans Neural Syst Rehabil Eng"},{"issue":"8","key":"2093_CR23","doi-asserted-by":"publisher","first-page":"1874","DOI":"10.1212\/WNL.53.8.1874","volume":"53","author":"B Volpe","year":"1999","unstructured":"Volpe B, Krebs H, Hogan N, Edelsteinn L, Diels C, Aisen M. Robot training enhanced motor outcome in patients with stroke maintained over 3 years. Neurology. 1999;53(8):1874\u20131874.","journal-title":"Neurology"},{"issue":"1","key":"2093_CR24","doi-asserted-by":"publisher","first-page":"11","DOI":"10.1007\/s42454-023-00048-y","volume":"5","author":"S Bhujel","year":"2023","unstructured":"Bhujel S, Hasan S. A comparative study of end-effector and exoskeleton type rehabilitation robots in human upper extremity rehabilitation. Human-Intell Syst Integration. 2023;5(1):11\u201342.","journal-title":"Human-Intell Syst Integration"},{"issue":"1","key":"2093_CR25","doi-asserted-by":"publisher","DOI":"10.1186\/s12938-023-01133-8","volume":"22","author":"S Forbrigger","year":"2023","unstructured":"Forbrigger S, DePaul VG, Davies TC, Morin E, Hashtrudi-Zaad K. Home-based upper limb stroke rehabilitation mechatronics: challenges and opportunities. Biomed Eng Online. 2023;22(1):67.","journal-title":"Biomed Eng Online"},{"key":"2093_CR26","doi-asserted-by":"publisher","first-page":"265","DOI":"10.1007\/978-3-031-99709-9_13","volume-title":"Enabling and safeguarding personalized medicine","author":"IG Aprile","year":"2025","unstructured":"Aprile IG, Germanotta M, Mauro MC, Fasano A. Bridging the gap: overcoming the barriers to using robotics in rehabilitation. In: Enabling and safeguarding personalized medicine. Cham: Springer Nature Switzerland; 2025. p. 265\u201376."},{"issue":"1","key":"2093_CR27","doi-asserted-by":"publisher","first-page":"142","DOI":"10.1186\/s12984-019-0612-y","volume":"16","author":"P Maceira-Elvira","year":"2019","unstructured":"Maceira-Elvira P, Popa T, Schmid A-C, Hummel FC. Wearable technology in stroke rehabilitation: towards improved diagnosis and treatment of upper-limb motor impairment. J Neuroeng Rehabil. 2019;16(1):142.","journal-title":"J Neuroeng Rehabil"},{"key":"2093_CR28","doi-asserted-by":"publisher","first-page":"20","DOI":"10.1186\/s12984-017-0229-y","volume":"14","author":"Q Wang","year":"2017","unstructured":"Wang Q, Markopoulos P, Yu B, Chen W, Timmermans A. Interactive wearable systems for upper body: a systematic review rehabilitation. J Neuroeng Rehabil. 2017;14:20.","journal-title":"J Neuroeng Rehabil"},{"key":"2093_CR29","doi-asserted-by":"crossref","unstructured":"Wittmann F, Lambercy O, Gonzenbach RR, van Raai MA, H\u00f6ver R, Held J, Starkey ML, Curt A, Luft A, Gassert R: Assessment-driven arm therapy at home using an IMU-based virtual reality system. In: 2015 IEEE international conference on rehabilitation robotics (ICORR): 2015. IEEE; 2015. pp. 707\u201312.","DOI":"10.1109\/ICORR.2015.7281284"},{"issue":"1","key":"2093_CR30","doi-asserted-by":"publisher","first-page":"122","DOI":"10.1186\/s12984-019-0595-8","volume":"16","author":"M Park","year":"2019","unstructured":"Park M, Ko M-H, Oh S-W, Lee J-Y, Ham Y, Yi H, et al. Effects of virtual reality-based planar motion exercises on upper extremity function, range of motion, and health-related quality of life: a multicenter, single-blinded, randomized, controlled pilot study. J Neuroeng Rehabil. 2019;16(1):122.","journal-title":"J Neuroeng Rehabil"},{"issue":"1","key":"2093_CR31","doi-asserted-by":"publisher","first-page":"17","DOI":"10.1186\/s12984-016-0125-x","volume":"13","author":"J-H Shin","year":"2016","unstructured":"Shin J-H, Kim M-Y, Lee J-Y, Jeon Y-J, Kim S, Lee S, et al. Effects of virtual reality-based rehabilitation on distal upper extremity function and health-related quality of life: a single-blinded, randomized controlled trial. J Neuroeng Rehabil. 2016;13(1):17.","journal-title":"J Neuroeng Rehabil"},{"issue":"7","key":"2093_CR32","doi-asserted-by":"publisher","first-page":"659","DOI":"10.3390\/bioengineering11070659","volume":"11","author":"F Ali","year":"2024","unstructured":"Ali F, Hogen CA, Miller EJ, Kaufman KR. Validation of pelvis and trunk range of motion as assessed using inertial measurement units. Bioengineering (Basel). 2024;11(7):659.","journal-title":"Bioengineering (Basel)"},{"key":"2093_CR33","doi-asserted-by":"publisher","first-page":"144","DOI":"10.1016\/j.medengphy.2020.08.001","volume":"84","author":"KD Dahl","year":"2020","unstructured":"Dahl KD, Dunford KM, Wilson SA, Turnbull TL, Tashman S. Wearable sensor validation of sports-related movements for the lower extremity and trunk. Med Eng Phys. 2020;84:144\u201350.","journal-title":"Med Eng Phys"},{"issue":"24","key":"2093_CR34","doi-asserted-by":"publisher","DOI":"10.3390\/s20247073","volume":"20","author":"MH Foreman","year":"2020","unstructured":"Foreman MH, Engsberg JR. The validity and reliability of the Microsoft Kinect for measuring trunk compensation during reaching. Sensors (Basel). 2020;20(24):7073.","journal-title":"Sensors (Basel)"},{"issue":"3","key":"2093_CR35","doi-asserted-by":"publisher","first-page":"53","DOI":"10.1007\/s10916-018-0905-x","volume":"42","author":"FL Siena","year":"2018","unstructured":"Siena FL, Byrom B, Watts P, Breedon P. Utilising the intel realsense camera for measuring health outcomes in clinical research. J Med Syst. 2018;42(3):53.","journal-title":"J Med Syst"},{"issue":"11","key":"2093_CR36","doi-asserted-by":"publisher","first-page":"8953","DOI":"10.1109\/JIOT.2021.3119328","volume":"9","author":"J Li","year":"2021","unstructured":"Li J, Liu X, Wang Z, Zhao H, Zhang T, Qiu S, et al. Real-time human motion capture based on wearable inertial sensor networks. IEEE Internet Things J. 2021;9(11):8953\u201366.","journal-title":"IEEE Internet Things J"},{"issue":"6","key":"2093_CR37","doi-asserted-by":"publisher","first-page":"806","DOI":"10.1080\/17461391.2018.1463397","volume":"18","author":"E Van der Kruk","year":"2018","unstructured":"Van der Kruk E, Reijne MM. Accuracy of human motion capture systems for sport applications; state-of-the-art review. Eur J Sport Sci. 2018;18(6):806\u201319.","journal-title":"Eur J Sport Sci"},{"key":"2093_CR38","unstructured":"Lugaresi C, Tang J, Nash H, McClanahan C, Uboweja E, Hays M, Zhang F, Chang C, Yong M, Lee J. Mediapipe: a framework for building perception pipelines. arXiv 2019. arXiv preprint arXiv:190608172 1906, 5."},{"key":"2093_CR39","doi-asserted-by":"crossref","unstructured":"Lafayette TBDG, Kunst VHDL, Melo PVDS, Guedes PDO, Teixeira JMXN, Vasconcelos CRD, Teichrieb V, Da Gama AEF. Validation of angle estimation based on body tracking data from RGB-D and RGB cameras for biomechanical assessment. Sensors. 2022;23(1):3.","DOI":"10.3390\/s23010003"},{"issue":"4","key":"2093_CR40","doi-asserted-by":"publisher","DOI":"10.3390\/app13042700","volume":"13","author":"J-W Kim","year":"2023","unstructured":"Kim J-W, Choi J-Y, Ha E-J, Choi J-H. Human pose estimation using mediapipe pose and optimization method based on a humanoid model. Appl Sci (Basel). 2023;13(4):2700.","journal-title":"Appl Sci (Basel)"},{"key":"2093_CR41","doi-asserted-by":"publisher","DOI":"10.3389\/fnhum.2022.918804","volume":"16","author":"D Fruchter","year":"2022","unstructured":"Fruchter D, Feingold Polak R, Berman S, Levy-Tzedek S. Automating provision of feedback to stroke patients with and without information on compensatory movements: a pilot study. Front Hum Neurosci. 2022;16:918804.","journal-title":"Front Hum Neurosci"},{"issue":"1","key":"2093_CR42","doi-asserted-by":"publisher","DOI":"10.1186\/s12938-024-01203-5","volume":"23","author":"A Barzegar Khanghah","year":"2024","unstructured":"Barzegar Khanghah A, Fernie G, Roshan Fekr A. Joint angle estimation during shoulder abduction exercise using contactless technology. Biomed Eng Online. 2024;23(1):11.","journal-title":"Biomed Eng Online"},{"issue":"1","key":"2093_CR43","doi-asserted-by":"publisher","first-page":"57","DOI":"10.1186\/s12984-023-01186-9","volume":"20","author":"WW Lam","year":"2023","unstructured":"Lam WW, Tang YM, Fong KN. A systematic review of the applications of markerless motion capture (MMC) technology for clinical measurement in rehabilitation. J Neuroeng Rehabil. 2023;20(1):57.","journal-title":"J Neuroeng Rehabil"},{"key":"2093_CR44","doi-asserted-by":"crossref","unstructured":"Park J, Jung H-T, Daneault J-F, Park S, Ryu T, Kim Y, Lee SI. Effectiveness of the RAPAEL smart board for upper limb therapy in stroke survivors: a pilot controlled trial. In: 2018 40th annual international conference of the IEEE engineering in medicine and biology society (EMBC): 2018: IEEE; 2018. pp. 2466\u20139.","DOI":"10.1109\/EMBC.2018.8512813"},{"key":"2093_CR45","unstructured":"Kang Y, NA D-L, Hahn S. A validity study on the Korean Mini-Mental state examination (K-MMSE) in dementia patients. J Korean Neurol Assoc. 1997:300\u20138."},{"issue":"9","key":"2093_CR46","doi-asserted-by":"publisher","first-page":"922","DOI":"10.1111\/j.1532-5415.1992.tb01992.x","volume":"40","author":"TN Tombaugh","year":"1992","unstructured":"Tombaugh TN, McIntyre NJ. The mini-mental state examination: a comprehensive review. J Am Geriatr Soc. 1992;40(9):922\u201335.","journal-title":"J Am Geriatr Soc"},{"issue":"4","key":"2093_CR47","doi-asserted-by":"publisher","first-page":"1149","DOI":"10.3758\/BRM.41.4.1149","volume":"41","author":"F Faul","year":"2009","unstructured":"Faul F, Erdfelder E, Buchner A, Lang A-G. Statistical power analyses using G* Power 3.1: tests for correlation and regression analyses. Behav Res Methods. 2009;41(4):1149\u201360.","journal-title":"Behav Res Methods"},{"key":"2093_CR48","doi-asserted-by":"publisher","DOI":"10.1155\/2017\/6190593","author":"S Jung","year":"2017","unstructured":"Jung S, Lee K, Kim M, Song C. Audiovisual biofeedback\u2010based trunk stabilization training using a pressure biofeedback system in stroke patients: a randomized, single\u2010blinded study. Stroke Res Treat. 2017. https:\/\/doi.org\/10.1155\/2017\/6190593.","journal-title":"Stroke Res Treat"},{"issue":"24","key":"2093_CR49","doi-asserted-by":"publisher","DOI":"10.3390\/s25247609","volume":"25","author":"C-L Thouant","year":"2025","unstructured":"Thouant C-L, Cocco ES, Morone G, Manzia CM, Infarinato F, Romano P, et al. Compensation strategies in post-stroke individuals: insights from upper body kinematics analysis based on inertial sensors. Sensors (Basel). 2025;25(24):7609.","journal-title":"Sensors (Basel)"},{"issue":"1","key":"2093_CR50","doi-asserted-by":"publisher","first-page":"13","DOI":"10.2340\/1650197771331","volume":"7","author":"AR Fugl-Meyer","year":"1975","unstructured":"Fugl-Meyer AR, J\u00e4\u00e4sk\u00f6 L, Leyman I, Olsson S, Steglind S. A method for evaluation of physical performance. Scand J Rehabil Med. 1975;7(1):13\u201331.","journal-title":"Scand J Rehabil Med"},{"key":"2093_CR51","volume-title":"Intel\u00ae RealSense\u2122 D400 series datasheet","author":"I Corporation","year":"2021","unstructured":"Corporation I. Intel\u00ae RealSense\u2122 D400 series datasheet. In.: Intel Corporation; 2021."},{"issue":"6","key":"2093_CR52","first-page":"382","volume":"19","author":"G Demeurisse","year":"1980","unstructured":"Demeurisse G, Demol O, Robaye E. Motor evaluation in vascular hemiplegia. Eur Neurol. 1980;19(6):382\u20139.","journal-title":"Eur Neurol"},{"issue":"7","key":"2093_CR53","doi-asserted-by":"publisher","first-page":"576","DOI":"10.1136\/jnnp.53.7.576","volume":"53","author":"C Collin","year":"1990","unstructured":"Collin C, Wade D. Assessing motor impairment after stroke: a pilot reliability study. J Neurol Neurosurg Psychiatry. 1990;53(7):576\u20139.","journal-title":"J Neurol Neurosurg Psychiatry"},{"issue":"23","key":"2093_CR54","doi-asserted-by":"publisher","DOI":"10.3390\/s24237772","volume":"24","author":"S Dill","year":"2024","unstructured":"Dill S, Ahmadi A, Grimmer M, Haufe D, Rohr M, Zhao Y, et al. Accuracy evaluation of 3d pose reconstruction algorithms through stereo camera information fusion for physical exercises with mediapipe pose. Sensors (Basel). 2024;24(23):7772.","journal-title":"Sensors (Basel)"},{"issue":"6","key":"2093_CR55","doi-asserted-by":"publisher","first-page":"455","DOI":"10.1080\/00222895.2013.826169","volume":"45","author":"R Sigrist","year":"2013","unstructured":"Sigrist R, Rauter G, Riener R, Wolf P. Terminal feedback outperforms concurrent visual, auditory, and haptic feedback in learning a complex rowing-type task. J Mot Behav. 2013;45(6):455\u201372.","journal-title":"J Mot Behav"},{"issue":"1","key":"2093_CR56","doi-asserted-by":"publisher","first-page":"21","DOI":"10.3758\/s13423-012-0333-8","volume":"20","author":"R Sigrist","year":"2013","unstructured":"Sigrist R, Rauter G, Riener R, Wolf P. Augmented visual, auditory, haptic, and multimodal feedback in motor learning: a review. Psychon Bull Rev. 2013;20(1):21\u201353.","journal-title":"Psychon Bull Rev"},{"key":"2093_CR57","doi-asserted-by":"crossref","unstructured":"Lin H-P, Kager S, Cheng H-J, Woolley D, Zhang X, Azhar M, Wenderoth N. Implementing markerless body tracking and multi-modal feedback for trunk flexion reduction in post-stroke rehabilitation robotic training. In: 2024 10th IEEE RAS\/embs international conference for biomedical robotics and biomechatronics (BioRob): 2024: IEEE; 2024. pp. 864\u20139.","DOI":"10.1109\/BioRob60516.2024.10719896"},{"key":"2093_CR58","doi-asserted-by":"publisher","DOI":"10.1016\/j.neuroimage.2021.118853","volume":"247","author":"DP Richardson","year":"2022","unstructured":"Richardson DP, Foxe JJ, Mazurek KA, Abraham N, Freedman EG. Neural markers of proactive and reactive cognitive control are altered during walking: a Mobile Brain-Body Imaging (MoBI) study. Neuroimage. 2022;247:118853.","journal-title":"Neuroimage"},{"key":"2093_CR59","doi-asserted-by":"publisher","first-page":"53","DOI":"10.5116\/ijme.4dfb.8dfd","volume":"2","author":"M Tavakol","year":"2011","unstructured":"Tavakol M, Dennick R. Making sense of Cronbach\u2019s alpha. Int J Med Educ. 2011;2:53.","journal-title":"Int J Med Educ"},{"issue":"5","key":"2093_CR60","doi-asserted-by":"publisher","first-page":"940","DOI":"10.1093\/brain\/123.5.940","volume":"123","author":"M Cirstea","year":"2000","unstructured":"Cirstea M, Levin MF. Compensatory strategies for reaching in stroke. Brain. 2000;123(5):940\u201353.","journal-title":"Brain"},{"issue":"4","key":"2093_CR61","doi-asserted-by":"publisher","first-page":"313","DOI":"10.1177\/1545968308328727","volume":"23","author":"MF Levin","year":"2009","unstructured":"Levin MF, Kleim JA, Wolf SL. What do motor \u201crecovery\u201d and \u201ccompensation\u201d mean in patients following stroke? Neurorehabil Neural Repair. 2009;23(4):313\u20139.","journal-title":"Neurorehabil Neural Repair"},{"key":"2093_CR62","first-page":"205566831882367","volume":"6","author":"MH Foreman","year":"2019","unstructured":"Foreman MH, Engsberg JR. A virtual reality tool for measuring and shaping trunk compensation for persons with stroke: design and initial feasibility testing. J Rehabil Assistive Technol Eng. 2019;6:2055668318823673.","journal-title":"J Rehabil Assistive Technol Eng"},{"issue":"13","key":"2093_CR63","doi-asserted-by":"publisher","DOI":"10.3390\/app15137620","volume":"15","author":"S Lee","year":"2025","unstructured":"Lee S, Yim J. Effect of virtual-reality-based training, including preceding trunk stabilization education, on postural control and balance in patients with stroke: a randomized controlled trial. Appl Sci. 2025;15(13):7620.","journal-title":"Appl Sci"}],"container-title":["Journal of NeuroEngineering and Rehabilitation"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12984-026-02093-5","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12984-026-02093-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12984-026-02093-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,10,20]],"date-time":"2026-10-20T02:03:34Z","timestamp":1792461814000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12984-026-02093-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7,16]]},"references-count":63,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["2093"],"URL":"https:\/\/doi.org\/10.1186\/s12984-026-02093-5","relation":{},"ISSN":["1743-0003"],"issn-type":[{"value":"1743-0003","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,7,16]]},"assertion":[{"value":"28 January 2026","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"6 July 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"16 July 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The study protocol was reviewed and approved by the Institutional Review Board (IRB) of Samsung Medical Center (Approval No. 2023-11-105), registered as a clinical trial (ClinicalTrials.gov Identifier: NCT07397767), and conducted in accordance with the Declaration of Helsinki.","order":1,"name":"Ethics","label":"Ethics approval and consent to participate","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Not applicable.","order":2,"name":"Ethics","label":"Consent for publication","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no competing interests.","order":3,"name":"Ethics","label":"Competing interests","group":{"name":"EthicsHeading","label":"Declarations"}}],"article-number":"302"}}