{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,16]],"date-time":"2026-10-16T19:47:16Z","timestamp":1792180036509,"version":"4.4.0"},"reference-count":23,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2020,10,17]],"date-time":"2020-10-17T00:00:00Z","timestamp":1602892800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2020,10,17]],"date-time":"2020-10-17T00:00:00Z","timestamp":1602892800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Fluids Barriers CNS"],"published-print":{"date-parts":[[2020,12]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Objectives<\/jats:title>\n                    <jats:p>Measurement of intracranial pressure (ICP) plays an important role in long-term monitoring and neuro-intensive treatment of patients with a cerebral shunt. Currently, only two complete telemetric implants with different technical features are available worldwide. This prospective pilot study aims to examine patients who had both probes implanted at overlapping times for clinical reasons and represents the first in vivo comparison of both measurement methods.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Materials and methods<\/jats:title>\n                    <jats:p>\n                      Patients with a primary subarachnoid hemorrhage or a spontaneous intracerebral hemorrhage with ventricular hemorrhage who had received a telemetric ICP probe (Raumedic\n                      <jats:sup>\u00ae<\/jats:sup>\n                      NEUROVENT\n                      <jats:sup>\u00ae<\/jats:sup>\n                      -P-tel) were included in the study. Conventional external ventricular drainages (EVD) and ventriculoperitoneal shunts with a telemetric ICP probe (Miethke Sensor Reservoir) were implanted in patients with hydrocephalus who required CSF (cerebrospinal fluid) drainage. Absolute ICP values from all systems were obtained. Due to the overlapping implantation time, parallel ICP measurements were performed via two devices simultaneously. ICP measurements via the sensor reservoir were repeated after 3 and 9\u00a0months. Differences between the absolute ICP values measured via the NEUROVENT\n                      <jats:sup>\u00ae<\/jats:sup>\n                      -P-tel probe, the Miethke sensor reservoir\n                      <jats:sup>\u00ae<\/jats:sup>\n                      , and the EVD were analyzed.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Seventeen patients were included in the present study between 2016 and 2018. 63% of all patients were male. In 11 patients the ICP measurements were followed up with both devices for 3\u00a0months. ICP measurements of the sensor reservoir showed corresponding trends in 9 cases compared to ICP measurement via the telemetry probe or EVD. Difference in absolute ICP values ranged between 14.5\u00a0mmHg and 0.0\u00a0mmHg. The average difference of the absolute ICP values in 8 cases was\u2009\u2264\u20093.5\u00a0mmHg.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>ICP measurements with both systems continuously showed synchronous absolute ICP values, however absolute values of ICP measurement with the different systems did not match.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s12987-020-00225-0","type":"journal-article","created":{"date-parts":[[2020,10,17]],"date-time":"2020-10-17T02:02:39Z","timestamp":1602900159000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":16,"title":["Comparative investigation of different telemetric methods for measuring intracranial pressure: a prospective pilot study"],"prefix":"10.1186","volume":"17","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-0110-5766","authenticated-orcid":false,"given":"S.","family":"Rot","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"M.","family":"Dweek","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"P.","family":"Gutowski","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"L.","family":"Goelz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"U.","family":"Meier","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"J.","family":"Lemcke","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2020,10,17]]},"reference":[{"issue":"5","key":"225_CR1","doi-asserted-by":"publisher","first-page":"1009","DOI":"10.1007\/s00701-013-1991-7","volume":"156","author":"S Antes","year":"2014","unstructured":"Antes S, Tschan CA, Kunze G, Ewert L, Zimmer A, Halfmann A, Oertel J. Clinical and radiological findings in long-term intracranial pressure monitoring. Acta Neurochir. 2014;156(5):1009\u201319 (discussion 19).","journal-title":"Acta Neurochir."},{"key":"225_CR2","doi-asserted-by":"publisher","first-page":"133","DOI":"10.1016\/j.wneu.2016.03.096","volume":"91","author":"S Antes","year":"2016","unstructured":"Antes S, Tschan CA, Heckelmann M, Breuskin D, Oertel J. Telemetric intracranial pressure monitoring with the Raumedic Neurovent P-tel. World Neurosurg. 2016;91:133\u201348.","journal-title":"World Neurosurg"},{"issue":"4","key":"225_CR3","doi-asserted-by":"publisher","first-page":"503","DOI":"10.3171\/jns.1977.47.4.0503","volume":"47","author":"JD Miller","year":"1977","unstructured":"Miller JD, Becker DP, Ward JD, Sullivan HG, Adams WE, Rosner MJ. Significance of intracranial hypertension in severe head injury. J Neurosurg. 1977;47(4):503\u201316.","journal-title":"J Neurosurg"},{"issue":"1 Suppl Operati","key":"225_CR4","first-page":"44","volume":"70","author":"S Welschehold","year":"2012","unstructured":"Welschehold S, Schmalhausen E, Dodier P, Vulcu S, Oertel J, Wagner W, Tschan CA. First clinical results with a new telemetric intracranial pressure-monitoring system. Neurosurgery. 2012;70(1 Suppl Operative):44\u20139.","journal-title":"Neurosurgery."},{"key":"225_CR5","doi-asserted-by":"publisher","first-page":"111","DOI":"10.1007\/978-3-7091-0956-4_20","volume":"114","author":"M Kiefer","year":"2012","unstructured":"Kiefer M, Antes S, Leonhardt S, Schmitt M, Orakcioglu B, Sakowitz OW, Eymann R. Telemetric ICP measurement with the first CE-approved device: data from animal experiments and initial clinical experiences. Acta Neurochirurgica Suppl. 2012;114:111\u20136.","journal-title":"Acta Neurochirurgica Suppl"},{"key":"225_CR6","first-page":"1","volume":"131","author":"J Tirado-Caballero","year":"2018","unstructured":"Tirado-Caballero J, Munoz-Nunez A, Rocha-Romero S, Rivero-Garvia M, Gomez-Gonzalez E, Marquez-Rivas J. Long-term reliability of the telemetric Neurovent-P-tel sensor: in vivo case report. J Neurosurg. 2018;131:1\u20134.","journal-title":"J Neurosurg."},{"issue":"6","key":"225_CR7","doi-asserted-by":"publisher","first-page":"572","DOI":"10.1055\/s-0037-1603632","volume":"78","author":"P Ertl","year":"2017","unstructured":"Ertl P, Hermann EJ, Heissler HE, Krauss JK. Telemetric intracranial pressure recording via a shunt system integrated sensor: a safety and feasibility study. J Neurol Surgery Part A, Central Eur Neurosur. 2017;78(6):572\u20135.","journal-title":"J Neurol Surgery Part A, Central Eur Neurosur"},{"key":"225_CR8","doi-asserted-by":"publisher","first-page":"e642","DOI":"10.1016\/j.wneu.2017.10.044","volume":"109","author":"S Antes","year":"2018","unstructured":"Antes S, Stadie A, Muller S, Linsler S, Breuskin D, Oertel J. Intracranial pressure-guided shunt valve adjustments with the Miethke sensor reservoir. World Neurosurg. 2018;109:e642\u201350.","journal-title":"World Neurosurg"},{"key":"225_CR9","unstructured":"Miethke C, inventorimplantat zur messung des intrakorporalen druckes mit telemetrischer messwert\u00fcbertragung 2012. IPC; A61B5\/03"},{"issue":"6","key":"225_CR10","doi-asserted-by":"publisher","first-page":"411","DOI":"10.1007\/s10877-006-9047-7","volume":"20","author":"A Brean","year":"2006","unstructured":"Brean A, Eide PK, Stubhaug A. Comparison of intracranial pressure measured simultaneously within the brain parenchyma and cerebral ventricles. J Clin Monit Comput. 2006;20(6):411\u20134.","journal-title":"J Clin Monit Comput"},{"issue":"1","key":"225_CR11","first-page":"21","volume":"2","author":"NM Razali","year":"2011","unstructured":"Razali NM, Wah YB. Power comparisons of Shapiro-Wilk, Kolmogorov-Smirnov, Lilliefors and Anderson-Darling tests. J Stat Model Analy. 2011;2(1):21\u201333.","journal-title":"J Stat Model Analy"},{"issue":"4","key":"225_CR12","doi-asserted-by":"publisher","first-page":"689","DOI":"10.1007\/s00381-013-2324-0","volume":"30","author":"FB Freimann","year":"2014","unstructured":"Freimann FB, Schulz M, Haberl H, Thomale UW. Feasibility of telemetric ICP-guided valve adjustments for complex shunt therapy. Child\u2019s Nervous System. 2014;30(4):689\u201397.","journal-title":"Child's Nervous System"},{"issue":"1","key":"225_CR13","doi-asserted-by":"publisher","first-page":"29","DOI":"10.1159\/000355561","volume":"49","author":"FB Freimann","year":"2013","unstructured":"Freimann FB, Sprung C, Chopra SS, Vajkoczy P, Wolf S. Large-scale referencing of the telemetric neurovent-P-tel intracranial pressure sensor in a porcine model. Pediatr Neurosurg. 2013;49(1):29\u201332.","journal-title":"Pediatr Neurosurg"},{"key":"225_CR14","doi-asserted-by":"publisher","first-page":"564","DOI":"10.1016\/j.wneu.2019.03.077","volume":"126","author":"J Norager","year":"2019","unstructured":"Norager J, et al. Deciding on appropriate telemetric intracranial pressure monitoring system. World Neurosur. 2019;126:564\u20139.","journal-title":"World Neurosur"},{"issue":"6","key":"225_CR15","doi-asserted-by":"publisher","first-page":"542","DOI":"10.1016\/j.medengphy.2005.09.003","volume":"28","author":"PK Eide","year":"2006","unstructured":"Eide PK. Comparison of simultaneous continuous intracranial pressure (ICP) signals from a Codman and a Camino ICP sensor. Med Eng Phys. 2006;28(6):542\u20139.","journal-title":"Med Eng Phys"},{"key":"225_CR16","doi-asserted-by":"publisher","first-page":"66","DOI":"10.1186\/1475-925X-11-66","volume":"11","author":"PK Eide","year":"2012","unstructured":"Eide PK, Holm S, Sorteberg W. Simultaneous monitoring of static and dynamic intracranial pressure parameters from two separate sensors in patients with cerebral bleeds: comparison of findings. Biomed Eng Online. 2012;11:66.","journal-title":"Biomed Eng Online"},{"issue":"6","key":"225_CR17","doi-asserted-by":"publisher","first-page":"1317","DOI":"10.3171\/2010.7.JNS10483","volume":"113","author":"PK Eide","year":"2010","unstructured":"Eide PK, Sorteberg W. Simultaneous measurements of intracranial pressure parameters in the epidural space and in brain parenchyma in patients with hydrocephalus. J Neurosurg. 2010;113(6):1317\u201325.","journal-title":"J Neurosurg"},{"issue":"4","key":"225_CR18","doi-asserted-by":"publisher","first-page":"231","DOI":"10.1007\/s10877-011-9300-6","volume":"25","author":"J Vender","year":"2011","unstructured":"Vender J, Waller J, Dhandapani K, McDonnell D. An evaluation and comparison of intraventricular, intraparenchymal, and fluid- coupled techniques for intracranial pressure monitoring in patients with severe traumatic brain injury. J Clin Monit Comput. 2011;25(4):231\u20136.","journal-title":"J Clin Monit Comput"},{"key":"225_CR19","unstructured":"G\u00f6hler KK, G.; Von Falkenhausen, C inventor; RAUMEDIC AG, assignee. Patent Data Sensor Device 2009. IPC; A61B5\/00"},{"issue":"6","key":"225_CR20","doi-asserted-by":"publisher","first-page":"950","DOI":"10.1016\/j.jamcollsurg.2012.03.004","volume":"214","author":"G Kasotakis","year":"2012","unstructured":"Kasotakis G, Michailidou M, Bramos A, Chang Y, Velmahos G, Alam H, King D, de Moya MA. Intraparenchymal vs extracranial ventricular drain intracranial pressure monitors in traumatic brain injury: less is more? J Am Coll Surg. 2012;214(6):950\u20137.","journal-title":"J Am Coll Surg"},{"issue":"11","key":"225_CR21","doi-asserted-by":"publisher","first-page":"2137","DOI":"10.1007\/s00701-018-3691-9","volume":"160","author":"NH Norager","year":"2018","unstructured":"Norager NH, Lilja-Cyron A, Bjarkam CR, Duus S, Juhler M. Telemetry in intracranial pressure monitoring: sensor survival and drift. Acta Neurochir. 2018;160(11):2137\u201344.","journal-title":"Acta Neurochir"},{"key":"225_CR22","doi-asserted-by":"publisher","first-page":"113","DOI":"10.1007\/978-3-211-98811-4_19","volume":"106","author":"J Lemcke","year":"2010","unstructured":"Lemcke J, Meier U, Muller C, Fritsch M, Eymann R, Kiefer M, Kehler U, Langer N, Rohde V, Ludwig HC, Weber F, Remenez V, Schumann M, Stengel D. Is it possible to minimize overdrainage complications with gravitational units in patients with idiopathic normal pressure hydrocephalus? Protocol of the randomized controlled SVASONA Trial (ISRCTN51046698). Acta Neurochirurgica Suppl. 2010;106:113\u20135.","journal-title":"Acta Neurochirurgica Suppl"},{"issue":"8","key":"225_CR23","doi-asserted-by":"publisher","first-page":"850","DOI":"10.1136\/jnnp-2012-303936","volume":"84","author":"J Lemcke","year":"2013","unstructured":"Lemcke J, Meier U, Muller C, Fritsch MJ, Kehler U, Langer N, Kiefer M, Eymann R, Schuhmann MU, Speil A, Weber F, Remenez V, Rohde V, Ludwig HC, Stengel D. Safety and efficacy of gravitational shunt valves in patients with idiopathic normal pressure hydrocephalus: a pragmatic, randomised, open label, multicentre trial (SVASONA). J Neurol Neurosur Psychiatry. 2013;84(8):850\u20137.","journal-title":"J Neurol Neurosur Psychiatry."}],"container-title":["Fluids and Barriers of the CNS"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12987-020-00225-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12987-020-00225-0\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12987-020-00225-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,10,16]],"date-time":"2021-10-16T19:36:33Z","timestamp":1634412993000},"score":1,"resource":{"primary":{"URL":"https:\/\/fluidsbarrierscns.biomedcentral.com\/articles\/10.1186\/s12987-020-00225-0"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,10,17]]},"references-count":23,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2020,12]]}},"alternative-id":["225"],"URL":"https:\/\/doi.org\/10.1186\/s12987-020-00225-0","relation":{"has-preprint":[{"id-type":"doi","id":"10.21203\/rs.3.rs-29450\/v5","asserted-by":"object"},{"id-type":"doi","id":"10.21203\/rs.3.rs-29450\/v1","asserted-by":"object"},{"id-type":"doi","id":"10.21203\/rs.3.rs-29450\/v2","asserted-by":"object"},{"id-type":"doi","id":"10.21203\/rs.3.rs-29450\/v3","asserted-by":"object"},{"id-type":"doi","id":"10.21203\/rs.3.rs-29450\/v4","asserted-by":"object"}]},"ISSN":["2045-8118"],"issn-type":[{"value":"2045-8118","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,10,17]]},"assertion":[{"value":"13 May 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"8 October 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"17 October 2020","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"All procedures performed in studies involving human participants were in accordance with the ethical standards of the institutional and committee and with the 1964 Helsinki declaration and its later amendments or comparable ethical standards. For this type of study formal consent is not required.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval and consent to participate"}},{"value":"All authors certify that they have no affiliations with or involvement in any organization or entity with any financial interest (such as honoraria; educational grants; participation in speakers\u2019 bureaus; membership, employment, consultancies, stock ownership, or other equity interest; and expert testimony or patent-licensing arrangements), or non-financial interest (such as personal or professional relationships, affiliations, knowledge or beliefs) in the subject matter or materials discussed in this manuscript.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"63"}}