{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,9]],"date-time":"2026-11-09T19:32:47Z","timestamp":1794252767322,"version":"4.9.0"},"reference-count":43,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,3,12]],"date-time":"2026-03-12T00:00:00Z","timestamp":1773273600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2026,4,21]],"date-time":"2026-04-21T00:00:00Z","timestamp":1776729600000},"content-version":"vor","delay-in-days":40,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Fluids Barriers CNS"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Understanding egress outflow of cerebrospinal fluid (CSF) is essential for exploring its role in brain health and its relationship to neurodegenerative diseases. Existing models often fail to capture the complex flow dynamics, particularly distinguishing rapid bulk flow from slower, perfusion-like components. This study aims to develop and validate a bi-component model that characterizes these distinct signal patterns using Time-Spatial Labeling Inversion Pulse (Time-SLIP) MRI data.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>\n                      A bi-component model is proposed by combining a Gaussian function (to represent fast bulk outflow) with a \u0413-variate function (representing slower, perfusion-like flow). Validation phantom studies were conducted using a sealed water phantom with computer-controlled bulk flow. In-vivo meninges images in eight healthy subjects were acquired on a clinical 3T MRI using Time-SLIP with 3D single-shot FSE. Signal Increase Ratio (SIR) from these experiments were fitted using the proposed bi-component model with fitting accuracy assessed using coefficient of determination (R\n                      <jats:sup>2<\/jats:sup>\n                      ), Sum of Squared estimate of Errors (SSE), and Root Mean Square Error (RMSE).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      Phantom studies showed superior fitting of bulk fluid dynamics by the Gaussian component, confirmed by lower SSE, RMSE and higher R\n                      <jats:sup>2<\/jats:sup>\n                      . The in-vivo results demonstrated that the bi-component model provided a superior fit, capturing two distinct components of CSF outflow, which are hypothesized to correspond to fast bulk flow and a slower, perfusion-like component, which could be a mixture of CSF and interstitial fluid.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>The bi-component model enhances characterization of CSF egress outflow from intrinsic labeling by Time-SLIP, providing potential quantitative biomarkers for the assessment of neurodegenerative diseases.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s12987-026-00791-9","type":"journal-article","created":{"date-parts":[[2026,3,12]],"date-time":"2026-03-12T16:33:08Z","timestamp":1773333188000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["Bi-component modeling of cerebrospinal fluid outflow using Time-SLIP MRI"],"prefix":"10.1186","volume":"23","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-0426-1457","authenticated-orcid":false,"given":"Vadim","family":"Malis","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2552-9480","authenticated-orcid":false,"given":"Mitsue","family":"Miyazaki","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2026,3,12]]},"reference":[{"key":"791_CR1","doi-asserted-by":"publisher","unstructured":"Iliff JJ, Wang M, Liao Y, Plogg BA, Peng W, Gundersen GA, et al. A paravascular pathway facilitates CSF flow through the brain parenchyma and the clearance of interstitial solutes, including amyloid \u03b2. Sci Transl Med. 2012;4:147ra111. https:\/\/doi.org\/10.1126\/scitranslmed.3003748.","DOI":"10.1126\/scitranslmed.3003748"},{"key":"791_CR2","doi-asserted-by":"publisher","first-page":"845","DOI":"10.1002\/ana.24271","volume":"76","author":"BT Kress","year":"2014","unstructured":"Kress BT, Iliff JJ, Xia M, Wang M, Wei HS, Zeppenfeld D, et al. Impairment of paravascular clearance pathways in the aging brain. Ann Neurol. 2014;76:845\u201361. https:\/\/doi.org\/10.1002\/ana.24271.","journal-title":"Ann Neurol"},{"key":"791_CR3","doi-asserted-by":"publisher","first-page":"457","DOI":"10.1038\/nrneurol.2015.119","volume":"11","author":"JM Tarasoff-Conway","year":"2015","unstructured":"Tarasoff-Conway JM, Carare RO, Osorio RS, Glodzik L, Butler T, Fieremans E, et al. Clearance systems in the brain-implications for Alzheimer disease. Nat Rev Neurol. 2015;11:457\u201370. https:\/\/doi.org\/10.1038\/nrneurol.2015.119.","journal-title":"Nat Rev Neurol"},{"key":"791_CR4","doi-asserted-by":"publisher","first-page":"2576","DOI":"10.1093\/brain\/awaa179","volume":"143","author":"IF Harrison","year":"2020","unstructured":"Harrison IF, Ismail O, Machhada A, Colgan N, Ohene Y, Nahavandi P, et al. Impaired glymphatic function and clearance of tau in an Alzheimer\u2019s disease model. Brain. 2020;143:2576\u201393. https:\/\/doi.org\/10.1093\/brain\/awaa179.","journal-title":"Brain"},{"key":"791_CR5","doi-asserted-by":"publisher","first-page":"8","DOI":"10.2214\/ajr.15.14884","volume":"206","author":"PG Kranz","year":"2016","unstructured":"Kranz PG, Luetmer PH, Diehn FE, Amrhein TJ, Tanpitukpongse TP, Gray L. Myelographic techniques for the detection of spinal CSF leaks in spontaneous intracranial hypotension. Am J Roentgenol. 2016;206:8\u201319. https:\/\/doi.org\/10.2214\/ajr.15.14884.","journal-title":"Am J Roentgenol"},{"key":"791_CR6","first-page":"706","volume":"20","author":"JA Stone","year":"1999","unstructured":"Stone JA, Castillo M, Neelon B, Mukherji SK. Evaluation of CSF leaks: high-resolution CT compared with contrast-enhanced CT and radionuclide cisternography. AJNR Am J Neuroradiol. 1999;20:706\u201312.","journal-title":"AJNR Am J Neuroradiol"},{"key":"791_CR7","doi-asserted-by":"publisher","first-page":"18190","DOI":"10.1523\/jneurosci.1592-13.2013","volume":"33","author":"JJ Iliff","year":"2013","unstructured":"Iliff JJ, Wang M, Zeppenfeld DM, Venkataraman A, Plog BA, Liao Y, et al. Cerebral arterial pulsation drives paravascular CSF-interstitial fluid exchange in the murine brain. J Neurosci. 2013;33:18190\u201399. https:\/\/doi.org\/10.1523\/jneurosci.1592-13.2013.","journal-title":"J Neurosci"},{"key":"791_CR8","doi-asserted-by":"publisher","unstructured":"Boyd ED, Kaur J, Ding G, Chopp M, Jiang Q. Clinical magnetic resonance imaging evaluation of glymphatic function. NMR Biomed. 2024;37:e5132. https:\/\/doi.org\/10.1002\/nbm.5132.","DOI":"10.1002\/nbm.5132"},{"key":"791_CR9","doi-asserted-by":"publisher","first-page":"2691","DOI":"10.1093\/brain\/awx191","volume":"140","author":"G Ringstad","year":"2017","unstructured":"Ringstad G, Vatnehol SAS, Eide PK. Glymphatic MRI in idiopathic normal pressure hydrocephalus. Brain. 2017;140:2691\u2013705. https:\/\/doi.org\/10.1093\/brain\/awx191.","journal-title":"Brain"},{"key":"791_CR10","doi-asserted-by":"publisher","first-page":"467","DOI":"10.1148\/radiology.178.2.1987610","volume":"178","author":"DR Enzmann","year":"1991","unstructured":"Enzmann DR, Pelc NJ. Normal flow patterns of intracranial and spinal cerebrospinal fluid defined with phase-contrast cine MR imaging. Radiology. 1991;178:467\u201374. https:\/\/doi.org\/10.1148\/radiology.178.2.1987610.","journal-title":"Radiology"},{"key":"791_CR11","doi-asserted-by":"publisher","first-page":"831","DOI":"10.3174\/ajnr.a4124","volume":"36","author":"WG Bradley","year":"2015","unstructured":"Bradley WG. CSF flow in the brain in the context of normal pressure hydrocephalus. Am J Neuroradiol. 2015;36:831\u201338. https:\/\/doi.org\/10.3174\/ajnr.a4124.","journal-title":"Am J Neuroradiol"},{"key":"791_CR12","doi-asserted-by":"publisher","first-page":"172","DOI":"10.1007\/s11604-017-0617-z","volume":"35","author":"T Taoka","year":"2017","unstructured":"Taoka T, Masutani Y, Kawai H, Nakane T, Matsuoka K, Yasuno F, et al. Evaluation of glymphatic system activity with the diffusion MR technique: diffusion tensor image analysis along the perivascular space (DTI-ALPS) in Alzheimer\u2019s disease cases. Jpn J Radiol. 2017;35:172\u201378. https:\/\/doi.org\/10.1007\/s11604-017-0617-z.","journal-title":"Jpn J Radiol"},{"key":"791_CR13","doi-asserted-by":"publisher","first-page":"1605889","DOI":"10.3389\/fneur.2025.1605889","volume":"16","author":"Y Wang","year":"2025","unstructured":"Wang Y, Yang M, Zeng X, Wang S, Zhang W, Wang W, et al. Glymphatic dysfunction assessed by DTI-ALPS index predicts early cognitive impairment in acute subcortical infarcts: a prospective clinical cohort study. Front Neurol. 2025;16:1605889. https:\/\/doi.org\/10.3389\/fneur.2025.1605889.","journal-title":"Front Neurol"},{"key":"791_CR14","doi-asserted-by":"publisher","first-page":"644","DOI":"10.1148\/radiol.2492071985","volume":"249","author":"S Yamada","year":"2008","unstructured":"Yamada S, Miyazaki M, Kanazawa H, Higashi M, Morohoshi Y, Bluml S, et al. Visualization of cerebrospinal fluid movement with spin labeling at MR imaging: preliminary results in normal and pathophysiologic conditions. Radiology. 2008;249:644\u201352. https:\/\/doi.org\/10.1148\/radiol.2492071985.","journal-title":"Radiology"},{"key":"791_CR15","doi-asserted-by":"publisher","first-page":"36","DOI":"10.1186\/2045-8118-10-36","volume":"10","author":"S Yamada","year":"2013","unstructured":"Yamada S, Miyazaki M, Yamashita Y, Ouyang C, Yui M, Nakahashi M, et al. Influence of respiration on cerebrospinal fluid movement using magnetic resonance spin labeling. Fluids Barriers CNS. 2013;10:36. https:\/\/doi.org\/10.1186\/2045-8118-10-36.","journal-title":"Fluids Barriers CNS"},{"key":"791_CR16","doi-asserted-by":"publisher","first-page":"623","DOI":"10.3174\/ajnr.a4030","volume":"36","author":"S Yamada","year":"2015","unstructured":"Yamada S, Tsuchiya K, Bradley WG, Law M, Winkler ML, Borzage MT, et al. Current and emerging MR imaging techniques for the diagnosis and management of CSF flow disorders: a review of phase-contrast and time-spatial labeling inversion pulse. Am J Neuroradiol. 2015;36:623\u201330. https:\/\/doi.org\/10.3174\/ajnr.a4030.","journal-title":"Am J Neuroradiol"},{"key":"791_CR17","doi-asserted-by":"publisher","first-page":"66","DOI":"10.2463\/mrms.mp.2022-0117","volume":"23","author":"V Malis","year":"2024","unstructured":"Malis V, Bae WC, Yamamoto A, McEvoy LK, McDonald MA, Miyazaki M. Age-related decline of intrinsic cerebrospinal fluid outflow in healthy humans detected with non-contrast spin-labeling MR imaging. Magn Reson Med Sci. 2024;23:66\u201379. https:\/\/doi.org\/10.2463\/mrms.mp.2022-0117.","journal-title":"Magn Reson Med Sci"},{"key":"791_CR18","doi-asserted-by":"publisher","first-page":"171","DOI":"10.2463\/mrms.mp.2023-0005","volume":"23","author":"M Miyazaki","year":"2024","unstructured":"Miyazaki M, Malis V, Yamamoto A, Kungsamutr J, McEvoy LK, McDonald MA, et al. Physical exercise alters egress pathways for intrinsic CSF outflow: an investigation performed with spin-labeling MR imaging. Magn Reson Med Sci. 2024;23:171\u201383. https:\/\/doi.org\/10.2463\/mrms.mp.2023-0005.","journal-title":"Magn Reson Med Sci"},{"key":"791_CR19","doi-asserted-by":"publisher","first-page":"9894","DOI":"10.1073\/pnas.1706942114","volume":"114","author":"KE Holter","year":"2017","unstructured":"Holter KE, Kehlet B, Devor A, Sejnowski TJ, Dale AM, Omholt SW, et al. Interstitial solute transport in 3D reconstructed neuropil occurs by diffusion rather than bulk flow. Proc Natl Acad Sci. 2017;114:9894\u201399. https:\/\/doi.org\/10.1073\/pnas.1706942114.","journal-title":"Proc. Natl. Acad. Sci"},{"key":"791_CR20","doi-asserted-by":"publisher","first-page":"1176","DOI":"10.3389\/fphys.2019.01176","volume":"10","author":"DJ Noble","year":"2019","unstructured":"Noble DJ, Hochman S. Hypothesis: pulmonary afferent activity patterns during slow, deep breathing contribute to the neural induction of physiological relaxation. Front Physiol. 2019;10:1176. https:\/\/doi.org\/10.3389\/fphys.2019.01176.","journal-title":"Front. Physiol"},{"key":"791_CR21","doi-asserted-by":"publisher","first-page":"387","DOI":"10.1007\/s00401-018-1812-4","volume":"135","author":"NJ Abbott","year":"2018","unstructured":"Abbott NJ, Pizzo ME, Preston JE, Janigro D, Thorne RG. The role of brain barriers in fluid movement in the CNS: is there a \u2018glymphatic\u2019 system? Acta Neuropathol. 2018;135:387\u2013407. https:\/\/doi.org\/10.1007\/s00401-018-1812-4.","journal-title":"Acta Neuropathol"},{"key":"791_CR22","doi-asserted-by":"publisher","first-page":"11034","DOI":"10.1523\/jneurosci.1625-15.2015","volume":"35","author":"H Lee","year":"2015","unstructured":"Lee H, Xie L, Yu M, Kang H, Feng T, Deane R, et al. The effect of body posture on brain glymphatic transport. J Neurosci. 2015;35:11034\u201344. https:\/\/doi.org\/10.1523\/jneurosci.1625-15.2015.","journal-title":"J Neurosci"},{"key":"791_CR23","doi-asserted-by":"publisher","first-page":"1990","DOI":"10.1038\/s41598-020-59045-9","volume":"10","author":"S Koundal","year":"2020","unstructured":"Koundal S, Elkin R, Nadeem S, Xue Y, Constantinou S, Sanggaard S, et al. Optimal mass transport with lagrangian workflow reveals advective and diffusion driven solute transport in the glymphatic system. Sci Rep. 2020;10:1990. https:\/\/doi.org\/10.1038\/s41598-020-59045-9.","journal-title":"Sci Rep"},{"key":"791_CR24","doi-asserted-by":"publisher","first-page":"50","DOI":"10.1016\/0014-4886(74)90099-5","volume":"45","author":"HF Cserr","year":"1974","unstructured":"Cserr HF, Ostrach LH. Bulk flow of interstitial fluid after intracranial injection of blue dextran 2000. Exp Neurol. 1974;45:50\u201360. https:\/\/doi.org\/10.1016\/0014-4886(74)90099-5.","journal-title":"Exp Neurol"},{"key":"791_CR25","doi-asserted-by":"publisher","first-page":"6","DOI":"10.1186\/s12987-019-0126-9","volume":"16","author":"L Ray","year":"2019","unstructured":"Ray L, Iliff JJ, Heys JJ. Analysis of convective and diffusive transport in the brain interstitium. Fluids Barriers CNS. 2019;16:6. https:\/\/doi.org\/10.1186\/s12987-019-0126-9.","journal-title":"Fluids Barriers CNS"},{"key":"791_CR26","doi-asserted-by":"publisher","unstructured":"Ringstad G, Valnes LM, Dale AM, Pripp AH, Vatnehol S-AS, Emblem KE, et al. Brain-wide glymphatic enhancement and clearance in humans assessed with MRI. JCI Insight. 2018;3:e121537. https:\/\/doi.org\/10.1172\/jci.insight.121537.","DOI":"10.1172\/jci.insight.121537"},{"key":"791_CR27","doi-asserted-by":"publisher","unstructured":"Malis V, Kuwatsuru Y, Miyazaki M. Perfusion signal analysis using multi-pulsed arterial spin labeling (mPASL) with multiple post-labeling delays: phantom validation and application to the human foot. Magn Reson Med Sci. 2025:mp.2025\u20130047. https:\/\/doi.org\/10.2463\/mrms.mp.2025-0047.","DOI":"10.2463\/mrms.mp.2025-0047"},{"key":"791_CR28","doi-asserted-by":"publisher","first-page":"101","DOI":"10.3389\/fnana.2017.00101","volume":"11","author":"A Bacyinski","year":"2017","unstructured":"Bacyinski A, Xu M, Wang W, Hu J. The paravascular pathway for brain waste clearance: current understanding, significance and controversy. Front Neuroanat. 2017;11:101. https:\/\/doi.org\/10.3389\/fnana.2017.00101.","journal-title":"Front Neuroanat"},{"key":"791_CR29","doi-asserted-by":"publisher","unstructured":"Harrison IF, Siow B, Akilo AB, Evans PG, Ismail O, Ohene Y, et al. Non-invasive imaging of CSF-mediated brain clearance pathways via assessment of perivascular fluid movement with diffusion tensor MRI. eLife. 2018; 7:e34028. https:\/\/doi.org\/10.7554\/elife.34028.","DOI":"10.7554\/elife.34028"},{"key":"791_CR30","doi-asserted-by":"publisher","first-page":"20230016","DOI":"10.1259\/bjr.20230016","volume":"96","author":"DJ Wang","year":"2023","unstructured":"Wang DJ, Hua J, Cao D, Ho M-L. Neurofluids and the glymphatic system: anatomy, physiology, and imaging. Br J Radiol. 2023;96:20230016. https:\/\/doi.org\/10.1259\/bjr.20230016.","journal-title":"The Br J Radiol"},{"key":"791_CR31","doi-asserted-by":"publisher","unstructured":"Malis V, Vucevic D, Bae WC, Yamamoto A, Kassai Y, Lane J, et al. Fast non-contrast MR angiography using a zigzag centric ky - kz k-space trajectory and exponential refocusing flip angles with restoration of longitudinal magnetization. Magn Reson Med Sci. 2024:mp.2023\u20130158. https:\/\/doi.org\/10.2463\/mrms.mp.2023-0158.","DOI":"10.2463\/mrms.mp.2023-0158"},{"key":"791_CR32","doi-asserted-by":"publisher","first-page":"899","DOI":"10.1007\/s10334-024-01166-7","volume":"37","author":"V Fritz","year":"2024","unstructured":"Fritz V, Eisele S, Martirosian P, Machann J, Schick F. A straightforward procedure to build a non-toxic relaxometry phantom with desired T1 and T2 times at 3T. Magn Reson Mater Phys Biol Med. 2024;37:899\u2013907. https:\/\/doi.org\/10.1007\/s10334-024-01166-7.","journal-title":"Magn Reson Mater Phys Biol Med"},{"key":"791_CR33","doi-asserted-by":"publisher","first-page":"3360","DOI":"10.1038\/s41467-025-58726-1","volume":"16","author":"R-E Yoo","year":"2025","unstructured":"Yoo R-E, Kim J-H, Moon HY, Park JY, Cheon S, Shin H-S, et al. Long-term physical exercise facilitates putative glymphatic and meningeal lymphatic vessel flow in humans. Nat Commun. 2025;16:3360. https:\/\/doi.org\/10.1038\/s41467-025-58726-1.","journal-title":"Nat Commun"},{"key":"791_CR34","doi-asserted-by":"publisher","first-page":"158","DOI":"10.1002\/mrm.30051","volume":"92","author":"W Shi","year":"2024","unstructured":"Shi W, Jiang D, Hu Z, Yedavalli V, Ge Y, Moghekar A, et al. VICTR: venous transit time imaging by changes in T1 relaxation. Magn Reson Med. 2024;92:158\u201372. https:\/\/doi.org\/10.1002\/mrm.30051.","journal-title":"Magn Reson Med"},{"key":"791_CR35","doi-asserted-by":"publisher","first-page":"3890","DOI":"10.1038\/s41467-025-59108-3","volume":"16","author":"E Karasan","year":"2025","unstructured":"Karasan E, Chen J, Maravilla J, Zhang Z, Liu C, Lustig M. MR perfusion source mapping depicts venous territories and reveals perfusion modulation during neural activation. Nat Commun. 2025;16:3890. https:\/\/doi.org\/10.1038\/s41467-025-59108-3.","journal-title":"Nat Commun"},{"key":"791_CR36","doi-asserted-by":"publisher","first-page":"61","DOI":"10.1002\/jmri.27399","volume":"55","author":"M Henningsson","year":"2022","unstructured":"Henningsson M, Malik S, Botnar R, Castellanos D, Hussain T, Leiner T. Black-blood contrast in cardiovascular MRI. J Magn Reson Imag. 2022;55:61\u201380. https:\/\/doi.org\/10.1002\/jmri.27399.","journal-title":"J Magn Reson Imag"},{"key":"791_CR37","doi-asserted-by":"publisher","first-page":"689","DOI":"10.1002\/mrm.1910330515","volume":"33","author":"JH Brittain","year":"1995","unstructured":"Brittain JH, Hu BS, Wright GA, Meyer CH, Macovski A, Nishimura DG. Coronary angiography with magnetization-prepared T2 contrast. Magn Reson Med. 1995;33:689\u201396. https:\/\/doi.org\/10.1002\/mrm.1910330515.","journal-title":"Magn Reson Med"},{"key":"791_CR38","doi-asserted-by":"publisher","first-page":"3139","DOI":"10.1161\/01.cir.99.24.3139","volume":"99","author":"RM Botnar","year":"1999","unstructured":"Botnar RM, Stuber M, Danias PG, Kissinger KV, Manning WJ. Improved coronary artery definition with T2-weighted, free-breathing, three-dimensional coronary MRA. Circulation. 1999;99:3139\u201348. https:\/\/doi.org\/10.1161\/01.cir.99.24.3139.","journal-title":"Circulation"},{"key":"791_CR39","doi-asserted-by":"publisher","first-page":"415","DOI":"10.1007\/s10334-017-0659-3","volume":"31","author":"JM Spijkerman","year":"2018","unstructured":"Spijkerman JM, Petersen ET, Hendrikse J, Luijten P, Zwanenburg JJM. T2 mapping of cerebrospinal fluid: 3 T versus 7 T. Magn Reson Mater Phys Biol Med. 2018;31:415\u201324. https:\/\/doi.org\/10.1007\/s10334-017-0659-3.","journal-title":"Magn Reson Mater Phys Biol Med"},{"key":"791_CR40","doi-asserted-by":"publisher","first-page":"679","DOI":"10.1002\/mrm.20178","volume":"52","author":"H Lu","year":"2004","unstructured":"Lu H, Clingman C, Golay X, van ZP. Determining the longitudinal relaxation time (T1) of blood at 3.0 Tesla. Magn Reson Med. 2004;52:679\u201382. https:\/\/doi.org\/10.1002\/mrm.20178.","journal-title":"Magn Reson Med"},{"key":"791_CR41","doi-asserted-by":"publisher","first-page":"592","DOI":"10.1002\/mrm.21342","volume":"58","author":"JM Zhao","year":"2007","unstructured":"Zhao JM, Clingman CS, N\u00e4rv\u00e4inen MJ, Kauppinen RA, van ZP. Oxygenation and hematocrit dependence of transverse relaxation rates of blood at 3T. Magn Reson Med. 2007;58:592\u201397. https:\/\/doi.org\/10.1002\/mrm.21342.","journal-title":"Magn Reson Med"},{"key":"791_CR42","doi-asserted-by":"publisher","first-page":"83","DOI":"10.1016\/s0730-725x(97)00250-6","volume":"16","author":"C Jones","year":"1998","unstructured":"Jones C, MacKay A, Rutt B. Bi-exponential T2 decay in dairy cream phantoms. Magn Reson Imag. 1998;16:83\u201385. https:\/\/doi.org\/10.1016\/s0730-725x(97)00250-6.","journal-title":"Magn Reson Imag"},{"key":"791_CR43","doi-asserted-by":"publisher","first-page":"1446","DOI":"10.1002\/mrm.29065","volume":"87","author":"BK Statton","year":"2022","unstructured":"Statton BK, Smith J, Finnegan ME, Koerzdoerfer G, Quest RA, Grech-Sollars M. Temperature dependence, accuracy, and repeatability of T1 and T2 relaxation times for the ISMRM\/NIST system phantom measured using MR fingerprinting. Magn Reson Med. 2022;87:1446\u201360. https:\/\/doi.org\/10.1002\/mrm.29065.","journal-title":"Magn Reson Med"}],"container-title":["Fluids and Barriers of the CNS"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s12987-026-00791-9","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12987-026-00791-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s12987-026-00791-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,6,16]],"date-time":"2026-06-16T19:56:34Z","timestamp":1781639794000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s12987-026-00791-9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,3,12]]},"references-count":43,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["791"],"URL":"https:\/\/doi.org\/10.1186\/s12987-026-00791-9","relation":{},"ISSN":["2045-8118"],"issn-type":[{"value":"2045-8118","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,3,12]]},"assertion":[{"value":"3 December 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"3 March 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"12 March 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"All experimental procedures involving human participants were reviewed and approved by the Institutional Review Board of the University of California San Diego. Written informed consent was obtained from all participants prior to MRI scanning. All methods were conducted in accordance with the ethical standards of the institutional research committee and with the Declaration of Helsinki (1964) and its later amendments.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"M.M. received a research support grant from Canon Medical Systems, Japan. The funding agency had no role in the study design, data collection, interpretation, or the decision to submit this work for publication; V.M. declares no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"61"}}