{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,16]],"date-time":"2026-09-16T02:04:56Z","timestamp":1789524296553,"version":"build-2803163510"},"reference-count":40,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2023,7,10]],"date-time":"2023-07-10T00:00:00Z","timestamp":1688947200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2023,7,10]],"date-time":"2023-07-10T00:00:00Z","timestamp":1688947200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Universit\u00e4tsklinikum Ulm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Head Face Med"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Computed tomography (CT) has become the primary imaging modality for visualization of the paranasal sinuses. In this retrospective, single center patient study the radiation dose development in the past 12 years in CT imaging of the paranasal sinuses was assessed.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>\n                      The computed tomography dose index (CTDI\n                      <jats:sub>Vol<\/jats:sub>\n                      ) and dose length product (DLP) of a total of 1246 patients (average age: 41\u2009\u00b1\u200918 years, 361 females, 885 males) were evaluated, who received imaging of the paranasal sinuses either for chronic sinusitis diagnostic, preoperatively or posttraumatically. Scans were performed on three different CT scanners (Somatom Definition AS, Somatom Definition AS+, Somatom Force, all from Siemens Healthineers) and on one CBCT (Morita) ranging from 2010 to 2022. Reconstruction techniques were filtered back projection and three generations of iterative reconstruction (IRIS, SAFIRE, ADMIRE, all from Siemens Healthineers). Group comparisons were performed using either parametrical (ANOVA) or non-parametrical tests (Kruskal-Wallis Test), where applicable.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      Over the past 12 years, there was a 73%, 54%, and 66% CTDI\n                      <jats:sub>Vol<\/jats:sub>\n                      reduction and a significant (p\u2009&lt;\u20090.001) 72%, 33%, and 67% DLP reduction in assessing the paranasal sinuses for chronic sinusitis, preoperatively and posttraumatically, respectively.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>Technological developments in CT imaging, both hardware and software based, have led to a significant reduction in dose exposure in recent years. Particularly in imaging of the paranasal sinuses, the reduction of radiation exposure is of great interest due to the often young patient age and radiation-sensitive organs in the area of radiation exposure.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s13005-023-00378-x","type":"journal-article","created":{"date-parts":[[2023,7,10]],"date-time":"2023-07-10T02:02:14Z","timestamp":1688954534000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":7,"title":["Dose development in sinonasal imaging over the last decade \u2013 a retrospective patient study"],"prefix":"10.1186","volume":"19","author":[{"given":"Carsten","family":"Hackenbroch","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Joachim Rudolf Balthasar","family":"Strobel","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kai Johannes","family":"Lorenz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Meinrad","family":"Beer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Simone","family":"Sch\u00fcle","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2023,7,10]]},"reference":[{"key":"378_CR1","doi-asserted-by":"publisher","first-page":"1","DOI":"10.4193\/Rhin20.401","volume":"58","author":"WJ Fokkens","year":"2020","unstructured":"Fokkens WJ, Lund VJ, Hopkins C, Hellings PW, Kern R, Reitsma S, et al. European position paper on Rhinosinusitis and nasal polyps 2020. Rhinology. 2020;58:1\u2013464.","journal-title":"Rhinology"},{"key":"378_CR2","doi-asserted-by":"publisher","first-page":"224","DOI":"10.1097\/00005537-200202000-00005","volume":"112","author":"RT Younis","year":"2002","unstructured":"Younis RT, Anand VK, Davidson B. The role of computed tomography and magnetic resonance imaging in patients with Sinusitis with Complications. Laryngoscope. 2002;112:224\u20139.","journal-title":"Laryngoscope"},{"key":"378_CR3","doi-asserted-by":"publisher","first-page":"10","DOI":"10.1148\/radiol.2016152230","volume":"281","author":"WT O\u2019Brien","year":"2016","unstructured":"O\u2019Brien WT, Hamelin S, Weitzel EK. The preoperative sinus CT: avoiding a \u201cCLOSE\u201d call with Surgical Complications. Radiology. 2016;281:10\u201321.","journal-title":"Radiology"},{"key":"378_CR4","doi-asserted-by":"publisher","first-page":"69","DOI":"10.1055\/s-0037-1601370","volume":"31","author":"TA Truong","year":"2017","unstructured":"Truong TA. Initial Assessment and evaluation of traumatic facial injuries. Semin Plast Surg. 2017;31:69\u201372.","journal-title":"Semin Plast Surg"},{"key":"378_CR5","doi-asserted-by":"publisher","first-page":"114","DOI":"10.1016\/j.ejrad.2017.02.021","volume":"90","author":"AA Schegerer","year":"2017","unstructured":"Schegerer AA, Nagel H-D, Stamm G, Adam G, Brix G. Current CT practice in Germany: results and implications of a nationwide survey. Eur J Radiol. 2017;90:114\u201328.","journal-title":"Eur J Radiol"},{"key":"378_CR6","doi-asserted-by":"publisher","first-page":"843","DOI":"10.1001\/jama.2019.11456","volume":"322","author":"R Smith-Bindman","year":"2019","unstructured":"Smith-Bindman R, Kwan ML, Marlow EC, Theis MK, Bolch W, Cheng SY, et al. Trends in Use of Medical Imaging in US Health Care Systems and in Ontario, Canada, 2000\u20132016. JAMA. 2019;322:843.","journal-title":"JAMA"},{"key":"378_CR7","doi-asserted-by":"publisher","first-page":"626","DOI":"10.2214\/AJR.12.9652","volume":"201","author":"M-K Yuan","year":"2013","unstructured":"Yuan M-K, Tsai D-C, Chang S-C, Yuan M-C, Chang S-J, Chen H-W, et al. The risk of Cataract Associated with repeated Head and Neck CT Studies: a Nationwide Population-Based study. Am J Roentgenol. 2013;201:626\u201330.","journal-title":"Am J Roentgenol"},{"key":"378_CR8","doi-asserted-by":"publisher","first-page":"109261","DOI":"10.1016\/j.ejrad.2020.109261","volume":"131","author":"R Booij","year":"2020","unstructured":"Booij R, Budde RPJ, Dijkshoorn ML, van Straten M. Technological developments of X-ray computed tomography over half a century: user\u2019s influence on protocol optimization. Eur J Radiol. 2020;131:109261.","journal-title":"Eur J Radiol"},{"key":"378_CR9","doi-asserted-by":"publisher","first-page":"2185","DOI":"10.1007\/s00330-018-5810-7","volume":"29","author":"MJ Willemink","year":"2019","unstructured":"Willemink MJ, No\u00ebl PB. The evolution of image reconstruction for CT\u2014from filtered back projection to artificial intelligence. Eur Radiol European Radiology. 2019;29:2185\u201395.","journal-title":"Eur Radiol European Radiology"},{"key":"378_CR10","doi-asserted-by":"publisher","first-page":"37","DOI":"10.1016\/j.jacr.2012.06.025","volume":"10","author":"SP Raman","year":"2013","unstructured":"Raman SP, Johnson PT, Deshmukh S, Mahesh M, Grant KL, Fishman EK. CT dose reduction applications: available tools on the latest generation of CT scanners. J Am Coll Radiol. 2013;10:37\u201341.","journal-title":"J Am Coll Radiol"},{"key":"378_CR11","unstructured":"Grant K, Flohr T. Iterative Reconstruction in Image Space (IRIS). 2010. https:\/\/www.static.healthcare.siemens.com\/. p. Accessed 12 Nov 2019."},{"key":"378_CR12","unstructured":"Grant K, Raupach RSAFIRE. Sinogram Affirmed Iterative Reconstruction. 2012. https:\/\/cdn0.scrvt.com\/39b415fb07de4d9656c7b516d8e2d907\/1800000000306520\/d80046026fd1\/ct_SAFIRE_White_Paper_1800000000306520.pdf. p. Assessed 12 Nov 2019."},{"key":"378_CR13","unstructured":"Ramirez-Giraldo JC, Grant KL, Raupach R. ADMIRE: Advanced Modeled Iterative Reconstruction. 2018. https:\/\/cdn0.scrvt.com\/39b415fb07de4d9656c7b516d8e2d907\/1800000005678345\/c5bb3dd343ed\/CT_Whitepaper_ADMIRE_1800000005678345.pdf. p. Assessed 12 Nov 2019."},{"key":"378_CR14","doi-asserted-by":"publisher","first-page":"3290","DOI":"10.1007\/s00330-017-4739-6","volume":"27","author":"M Messerli","year":"2017","unstructured":"Messerli M, Kluckert T, Knitel M, W\u00e4lti S, Desbiolles L, Rengier F, et al. Ultralow dose CT for pulmonary nodule detection with chest x-ray equivalent dose \u2013 a prospective intra-individual comparative study. Eur Radiol. 2017;27:3290\u20139.","journal-title":"Eur Radiol"},{"key":"378_CR15","doi-asserted-by":"publisher","first-page":"155","DOI":"10.1097\/RLI.0000000000000325","volume":"52","author":"M Weis","year":"2017","unstructured":"Weis M, Henzler T, Nance JW, Haubenreisser H, Meyer M, Sudarski S, et al. Radiation dose comparison between 70 kVp and 100 kVp with spectral beam shaping for non-contrast-enhanced pediatric chest computed tomography. Invest Radiol. 2017;52:155\u201362.","journal-title":"Invest Radiol"},{"key":"378_CR16","doi-asserted-by":"publisher","first-page":"169","DOI":"10.1007\/s00234-016-1780-0","volume":"59","author":"MS May","year":"2017","unstructured":"May MS, Brand M, Lell MM, Sedlmair M, Allmendinger T, Uder M, et al. Radiation dose reduction in parasinus CT by spectral shaping. Neuroradiology. 2017;59:169\u201376.","journal-title":"Neuroradiology"},{"key":"378_CR17","doi-asserted-by":"publisher","first-page":"4155","DOI":"10.1007\/s00330-016-4263-0","volume":"26","author":"W Wuest","year":"2016","unstructured":"Wuest W, May M, Saake M, Brand M, Uder M, Lell M. Low-dose CT of the Paranasal Sinuses: minimizing X-Ray exposure with spectral shaping. Eur Radiol. 2016;26:4155\u201361.","journal-title":"Eur Radiol"},{"key":"378_CR18","doi-asserted-by":"publisher","first-page":"1225","DOI":"10.3174\/ajnr.A4270","volume":"36","author":"MM Lell","year":"2015","unstructured":"Lell MM, May MS, Brand M, Eller A, Buder T, Hofmann E, et al. Imaging the Parasinus Region with a third-generation dual-source CT and the Effect of Tin Filtration on Image Quality and Radiation Dose. Am J Neuroradiol. 2015;36:1225\u201330.","journal-title":"Am J Neuroradiol"},{"key":"378_CR19","doi-asserted-by":"publisher","first-page":"e0279907","DOI":"10.1371\/journal.pone.0279907","volume":"18","author":"S Sch\u00fcle","year":"2023","unstructured":"Sch\u00fcle S, Strobel JRB, Lorenz KJ, Beer M, Hackenbroch C. Tin filter compared to low kV protocols - optimizing sinonasal imaging in computed tomography. PLoS ONE. 2023;18:e0279907.","journal-title":"PLoS ONE"},{"key":"378_CR20","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1371\/journal.pone.0216295","volume":"14","author":"B Petritsch","year":"2019","unstructured":"Petritsch B, Kosmala A, Weng AM, Bley TA. Tin-filtered 100\u00a0kV ultra-low-dose CT of the paranasal sinus: initial clinical results. PLoS ONE. 2019;14:1\u201310.","journal-title":"PLoS ONE"},{"key":"378_CR21","doi-asserted-by":"publisher","first-page":"662","DOI":"10.1002\/lio2.792","volume":"7","author":"M Han","year":"2022","unstructured":"Han M, Kim HJ, Choi JW, Park DY, Han JG. Diagnostic usefulness of cone-beam computed tomography versus multi-detector computed tomography for sinonasal structure evaluation. Laryngoscope Investig Otolaryngol. 2022;7:662\u201370.","journal-title":"Laryngoscope Investig Otolaryngol"},{"key":"378_CR22","doi-asserted-by":"publisher","first-page":"59","DOI":"10.1016\/j.amjoto.2015.08.002","volume":"37","author":"J Al Abduwani","year":"2016","unstructured":"Al Abduwani J, ZilinSkiene L, Colley S, Ahmed S. Cone beam CT paranasal sinuses versus standard multidetector and low dose multidetector CT studies. Am J Otolaryngol. 2016;37:59\u201364.","journal-title":"Am J Otolaryngol"},{"key":"378_CR23","doi-asserted-by":"publisher","first-page":"301","DOI":"10.1007\/s00784-013-0948-9","volume":"18","author":"E Hofmann","year":"2014","unstructured":"Hofmann E, Schmid M, Sedlmair M, Banckwitz R, Hirschfelder U, Lell M. Comparative study of image quality and radiation dose of cone beam and low-dose multislice computed tomography - an in-vitro investigation. Clin Oral Investig. 2014;18:301\u201311.","journal-title":"Clin Oral Investig"},{"key":"378_CR24","doi-asserted-by":"publisher","first-page":"790","DOI":"10.1007\/s00330-016-4387-2","volume":"27","author":"S Veldhoen","year":"2017","unstructured":"Veldhoen S, Sch\u00f6llchen M, Hanken H, Precht C, Henes FO, Sch\u00f6n G, et al. Performance of cone-beam computed tomography and multidetector computed tomography in diagnostic imaging of the midface: a comparative study on Phantom and cadaver head scans. Eur Radiol. 2017;27:790\u2013800.","journal-title":"Eur Radiol"},{"key":"378_CR25","doi-asserted-by":"publisher","first-page":"175","DOI":"10.1016\/j.jacr.2022.02.011","volume":"19","author":"M Hagiwara","year":"2022","unstructured":"Hagiwara M, Policeni B, Juliano AF, Agarwal M, Burns J, Dubey P, et al. ACR appropriateness Criteria\u00ae Sinonasal Disease: 2021 update. J Am Coll Radiol. 2022;19:175\u201393.","journal-title":"J Am Coll Radiol"},{"key":"378_CR26","unstructured":"Ulzheimer S, Freund J. The Stellar Detector (White Paper). 2013. https:\/\/sgcimages.s3.amazonaws.com\/SiemensOutsert_TheStellarDetector_ITN0913.pdf. p. Assessed 21 Feb 2023."},{"key":"378_CR27","doi-asserted-by":"publisher","first-page":"1072","DOI":"10.3174\/ajnr.A3339","volume":"34","author":"B Schulz","year":"2013","unstructured":"Schulz B, Beeres M, Bodelle B, Bauer R, Al-Butmeh F, Thalhammer A, et al. Performance of iterative image reconstruction in CT of the paranasal sinuses: a phantom study. Am J Neuroradiol. 2013;34:1072\u20136.","journal-title":"Am J Neuroradiol"},{"key":"378_CR28","doi-asserted-by":"publisher","first-page":"982","DOI":"10.1177\/0194599816664335","volume":"155","author":"M Bang","year":"2016","unstructured":"Bang M, Choi SH, Park J, Kang BS, Kwon WJ, Lee TH, et al. Radiation Dose reduction in Paranasal Sinus CT. Otolaryngol Neck Surg. 2016;155:982\u20137.","journal-title":"Otolaryngol Neck Surg"},{"key":"378_CR29","doi-asserted-by":"publisher","first-page":"644","DOI":"10.3174\/ajnr.A3749","volume":"35","author":"JM Hoxworth","year":"2014","unstructured":"Hoxworth JM, Lal D, Fletcher GP, Patel AC, He M, Paden RG, et al. Radiation dose reduction in paranasal sinus CT using model-based iterative reconstruction. Am J Neuroradiol. 2014;35:644\u20139.","journal-title":"Am J Neuroradiol"},{"key":"378_CR30","doi-asserted-by":"publisher","first-page":"907","DOI":"10.1007\/s00117-010-2066-x","volume":"50","author":"R Veit","year":"2010","unstructured":"Veit R, Guggenberger R, No\u00dfke D, Brix G. Diagnostic reference levels for X-ray examinations: Update 2010. Radiologe. 2010;50:907\u201312.","journal-title":"Radiologe"},{"key":"378_CR31","doi-asserted-by":"crossref","unstructured":"Schegerer A, Loose R, Heuser LJ, Brix G, Schegerer A. Diagnostic Reference Levels for Diagnostic and Interventional X-Ray Procedures in Germany: Update and Handling Diagnostische Referenzwerte f\u00fcr diagnostische und interventionelle R\u00f6ntgenanwendungen in Deutschland: Aktualisierung und Handhabung. Diagnostic Ref Levels? Fortschr R\u00f6ntgenstr. 2019;191:739\u201351","DOI":"10.1055\/a-0824-7603"},{"key":"378_CR32","unstructured":"Bundesamt f\u00fcr Strahlenschutz (BfS). Bekanntmachung der aktualisierten diagnostischen Referenzwerte f\u00fcr diagnostische und interventionelle R\u00f6ntgenanwendungen. 2022. https:\/\/www.bfs.de\/SharedDocs\/Downloads\/BfS\/DE\/fachinfo\/ion\/drw-roentgen.pdf?__blob=publicationFile&v=11. p. Assessed 21 Feb 2023."},{"key":"378_CR33","doi-asserted-by":"publisher","first-page":"120","DOI":"10.1148\/radiol.2017161911","volume":"284","author":"KM Kanal","year":"2017","unstructured":"Kanal KM, Butler PF, Sengupta D, Bhargavan-Chatfield M, Coombs LP, Morin RL. U.S. diagnostic reference levels and achievable doses for 10 adult CT examinations. Radiology. 2017;284:120\u201333.","journal-title":"Radiology"},{"key":"378_CR34","unstructured":"American College of Radiology. PRACTICE PARAMETER FOR DIAGNOSTIC REFERENCE LEVELS AND ACHIEVABLE DOSES IN MEDICAL X-RAY IMAGING. 2018. https:\/\/www.acr.org\/-\/media\/ACR\/Files\/Practice-Parameters\/diag-ref-levels.pdf. p. Assessed 21 Feb 2023."},{"key":"378_CR35","unstructured":"UK Health Security Agengy. National Diagnostic Reference Levels (NDRLs) from 13 October 2022. 2022. https:\/\/www.gov.uk\/government\/publications\/diagnostic-radiology-national-diagnostic-reference-levels-ndrls\/ndrl#fn:1. p. Assessed 21 Feb 2023."},{"key":"378_CR36","doi-asserted-by":"publisher","first-page":"265","DOI":"10.1055\/s-2004-813951","volume":"177","author":"M Lorenzen","year":"2005","unstructured":"Lorenzen M, Wedeg\u00e4rtner U, Weber C, Lockemann U, Adam G, Lorenzen J. Dosisoptimierung der mehrzeilen-spiral-CT (MSCT) des mittelgesichts. RoFo Fortschr auf dem Gebiet der Rontgenstrahlen und der Bildgeb Verfahren. 2005;177:265\u201371.","journal-title":"RoFo Fortschr auf dem Gebiet der Rontgenstrahlen und der Bildgeb Verfahren"},{"key":"378_CR37","doi-asserted-by":"crossref","unstructured":"Wedeg\u00e4rtner U, Thurmann H, Schmidt R, Adam G. Strahlenexposition bei der mehrschicht-spiral-CT (MSCT) von kopf, mittelgesicht und beckenskelett: Vergleich mit dem einzeilen-spiral-CT (SSCT). RoFo Fortschritte auf dem Gebiet der Rontgenstrahlen und der Bildgeb Verfahren. 2003;175:234\u20138.","DOI":"10.1055\/s-2003-37242"},{"issue":"Suppl 1","key":"378_CR38","first-page":"248","volume":"94","author":"S Langner","year":"2015","unstructured":"Langner S. Optimized imaging of the midface and orbits. Laryngorhinootologie. 2015;94(Suppl 1):248\u201371.","journal-title":"Laryngorhinootologie"},{"key":"378_CR39","doi-asserted-by":"publisher","first-page":"728","DOI":"10.1097\/RLI.0000000000000887","volume":"57","author":"JP Grunz","year":"2022","unstructured":"Grunz JP, Petritsch B, Luetkens KS, Kunz AS, Lennartz S, Erg\u00fcn S, et al. Ultra-Low-Dose Photon-Counting CT imaging of the Paranasal Sinus with Tin Prefiltration: how low can we go? Invest Radiol. 2022;57:728\u201333.","journal-title":"Invest Radiol"},{"key":"378_CR40","doi-asserted-by":"publisher","first-page":"91","DOI":"10.1097\/RLI.0000000000000614","volume":"55","author":"K Rajendran","year":"2020","unstructured":"Rajendran K, Voss BA, Zhou W, Tao S, Delone DR, Lane JI, et al. Dose reduction for sinus and temporal bone imaging using photon-counting detector CT with an additional tin Filter. Invest Radiol. 2020;55:91\u2013100.","journal-title":"Invest Radiol"}],"container-title":["Head &amp; Face Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13005-023-00378-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s13005-023-00378-x\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13005-023-00378-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,7,10]],"date-time":"2023-07-10T02:08:16Z","timestamp":1688954896000},"score":1,"resource":{"primary":{"URL":"https:\/\/head-face-med.biomedcentral.com\/articles\/10.1186\/s13005-023-00378-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,7,10]]},"references-count":40,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2023,12]]}},"alternative-id":["378"],"URL":"https:\/\/doi.org\/10.1186\/s13005-023-00378-x","relation":{},"ISSN":["1746-160X"],"issn-type":[{"value":"1746-160X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,7,10]]},"assertion":[{"value":"7 April 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"1 July 2023","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"10 July 2023","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Ethics approval for this single-center retrospective patient study was waived by the local institutional review board.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they have no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"28"}}