{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,28]],"date-time":"2026-07-28T23:30:59Z","timestamp":1785281459573,"version":"3.55.0"},"reference-count":35,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2024,2,17]],"date-time":"2024-02-17T00:00:00Z","timestamp":1708128000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2024,2,17]],"date-time":"2024-02-17T00:00:00Z","timestamp":1708128000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Herzzentrum G\u00f6ttingen"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Head Face Med"],"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>Real-time magnetic resonance imaging (rtMRI) is essential for diagnosing and comprehending temporomandibular joint (TMJ) movements. Current methods for tracking and analysis require manual landmark placement on each acquisition frame. Therefore, our study aimed to assess the inter- and intra-rater reliability of placing cephalometric landmarks in frames from a dynamic real-time TMJ MRI.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Material and methods<\/jats:title>\n                <jats:p>Four real-time MRIs of the right TMJ were taken during mandibular movement at ten frames per second. Seven dentists identified ten landmarks on two frames (intercuspal position\u2014ICP\u2014and maximum mouth opening\u2014MMO) twice at a two-week interval, yielding 112 tracings. Six typical cephalometric measurements (angles and distances) were derived from these landmarks. The reliabilities of landmarks and measurements were evaluated using distance-based (dbICC), linear mixed effect model intraclass correlation (lmeICC), and standard ICC.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>The average inter-rater reliability for the landmarks stood at 0.92 (dbICC) and 0.93 (lmeICC). The intra-rater reliability scores were 0.97 and 0.98. Over 80% of the landmarks showed an ICC greater than 0.98 (inter-rater) and over 0.99 (intra-rater). The lowest landmark ICC was observed for the orbitale and the oblique ridge of the mandibular ramus. However, the cephalometric angle and distance measurements derived from these landmarks showed only moderate to good reliability, whereas the reliability in the frames with ICP was better than those with MMO. Measurements performed in the ICP frame were more reliable than measurements in the MMO frame.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusion<\/jats:title>\n                <jats:p>While dentists reliably localize isolated landmarks in real-time MRIs, the cephalometric measurements derived from them remain inconsistent. The better results in ICP than MMO are probably due to a more familiar jaw position. The higher error rate of the TMJ measurements in MMO could be associated with a lack of training in real-time MRI analysis in dentistry.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s13005-024-00411-7","type":"journal-article","created":{"date-parts":[[2024,2,17]],"date-time":"2024-02-17T03:02:07Z","timestamp":1708138927000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":8,"title":["Reliability of landmark identification for analysis of the temporomandibular joint in real-time MRI"],"prefix":"10.1186","volume":"20","author":[{"given":"J\u00e9r\u00e9my","family":"Mouchoux","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Philipp","family":"Meyer-Marcotty","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Florian","family":"Sojka","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Peter","family":"Dechent","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daniela","family":"Klenke","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bernhard","family":"Wiechens","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anja","family":"Quast","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2024,2,17]]},"reference":[{"key":"411_CR1","doi-asserted-by":"publisher","first-page":"1303","DOI":"10.1016\/j.ijom.2020.02.011","volume":"49","author":"A Quast","year":"2020","unstructured":"Quast A, Santander P, Trautmann J, Moser N, Schliephake H, Meyer-Marcotty P. A new approach in three dimensions to define pre- and intraoperative condyle-fossa relationships in orthognathic surgery - is there an effect of general anaesthesia on condylar position? Int J Oral Maxillofac Surg. 2020;49:1303\u201310. https:\/\/doi.org\/10.1016\/j.ijom.2020.02.011.","journal-title":"Int J Oral Maxillofac Surg"},{"key":"411_CR2","doi-asserted-by":"publisher","first-page":"56","DOI":"10.1007\/s12663-023-01897-5","volume":"22","author":"A Krishnadas","year":"2023","unstructured":"Krishnadas A, Subash P, Iyer S, Manju V, Thankappan K, Pullan S, et al. Controlling and stabilising mandible during reconstruction: significance and techniques. J Maxillofac Oral Surg. 2023;22:56\u201363. https:\/\/doi.org\/10.1007\/s12663-023-01897-5.","journal-title":"J Maxillofac Oral Surg"},{"key":"411_CR3","doi-asserted-by":"publisher","first-page":"269","DOI":"10.1016\/S0720-048X(03)00218-3","volume":"51","author":"L Incesu","year":"2004","unstructured":"Incesu L, Ta\u015fkaya-Yilmaz N, O\u011f\u00fctcen-Toller M, Uzun E. Relationship of condylar position to disc position and morphology. Eur J Radiol. 2004;51:269\u201373. https:\/\/doi.org\/10.1016\/S0720-048X(03)00218-3.","journal-title":"Eur J Radiol"},{"key":"411_CR4","doi-asserted-by":"publisher","first-page":"15","DOI":"10.1186\/s13005-018-0173-5","volume":"14","author":"D Klenke","year":"2018","unstructured":"Klenke D, Quast A, Prelog M, Holl-Wieden A, Riekert M, Stellzig-Eisenhauer A, Meyer-Marcotty P. TMJ pathomorphology in patients with JIA-radiographic parameters for early diagnosis. Head Face Med. 2018;14:15. https:\/\/doi.org\/10.1186\/s13005-018-0173-5.","journal-title":"Head Face Med"},{"key":"411_CR5","doi-asserted-by":"publisher","first-page":"33","DOI":"10.1186\/s13005-020-00245-z","volume":"16","author":"P Santander","year":"2020","unstructured":"Santander P, Quast A, Olbrisch C, Rose M, Moser N, Schliephake H, Meyer-Marcotty P. Comprehensive 3D analysis of condylar morphology in adults with different skeletal patterns - a cross-sectional study. Head Face Med. 2020;16:33. https:\/\/doi.org\/10.1186\/s13005-020-00245-z.","journal-title":"Head Face Med"},{"key":"411_CR6","doi-asserted-by":"publisher","first-page":"64","DOI":"10.1046\/j.1365-2842.2002.00785.x","volume":"29","author":"M Nagata","year":"2002","unstructured":"Nagata M, Yamasaki Y, Hayasaki H, Nakata M. Incisal and condylar paths during habitual mouth opening movement of children with anterior reverse bite in the primary dentition. J Oral Rehabil. 2002;29:64\u201371. https:\/\/doi.org\/10.1046\/j.1365-2842.2002.00785.x.","journal-title":"J Oral Rehabil"},{"key":"411_CR7","doi-asserted-by":"publisher","first-page":"190","DOI":"10.1016\/j.prosdent.2005.04.025","volume":"94","author":"N Kucukkeles","year":"2005","unstructured":"Kucukkeles N, Ozkan H, Ari-Demirkaya A, Cilingirturk AM. Compatibility of mechanical and computerized axiographs: a pilot study. J Prosthet Dent. 2005;94:190\u20134. https:\/\/doi.org\/10.1016\/j.prosdent.2005.04.025.","journal-title":"J Prosthet Dent"},{"key":"411_CR8","doi-asserted-by":"publisher","first-page":"123","DOI":"10.1111\/jopr.12389","volume":"26","author":"A S\u00f3jka","year":"2017","unstructured":"S\u00f3jka A, Huber J, Kaczmarek E, H\u0119dzelek W. Evaluation of mandibular movement functions using instrumental ultrasound system. J Prosthodont. 2017;26:123\u20138. https:\/\/doi.org\/10.1111\/jopr.12389.","journal-title":"J Prosthodont"},{"key":"411_CR9","doi-asserted-by":"publisher","DOI":"10.21767\/2471-8564.100003","author":"A Shah","year":"2018","unstructured":"Shah A. Use of MRI in orthodontics - a review. J Imaging Interv Radiol. 2018. https:\/\/doi.org\/10.21767\/2471-8564.100003.","journal-title":"J Imaging Interv Radiol"},{"key":"411_CR10","doi-asserted-by":"publisher","first-page":"e340","DOI":"10.1016\/j.joms.2011.02.038","volume":"69","author":"X-Y Cai","year":"2011","unstructured":"Cai X-Y, Jin J-M, Yang C. Changes in disc position, disc length, and condylar height in the temporomandibular joint with anterior disc displacement: a longitudinal retrospective magnetic resonance imaging study. J Oral Maxillofac Surg. 2011;69:e340\u20136. https:\/\/doi.org\/10.1016\/j.joms.2011.02.038.","journal-title":"J Oral Maxillofac Surg"},{"key":"411_CR11","doi-asserted-by":"publisher","first-page":"313","DOI":"10.1080\/08869634.1992.11677928","volume":"10","author":"KA Bell","year":"1992","unstructured":"Bell KA, Miller KD, Jones JP. Cine magnetic resonance imaging of the temporomandibular joint. Cranio - J Craniomandib. 1992;10:313\u20137. https:\/\/doi.org\/10.1080\/08869634.1992.11677928.","journal-title":"Cranio - J Craniomandib"},{"key":"411_CR12","doi-asserted-by":"publisher","first-page":"757","DOI":"10.1097\/RLI.0000000000000584","volume":"54","author":"J Frahm","year":"2019","unstructured":"Frahm J, Voit D, Uecker M. Real-time magnetic resonance imaging: radial gradient-echo sequences with nonlinear inverse reconstruction. Investig Radiol. 2019;54:757\u201366. https:\/\/doi.org\/10.1097\/RLI.0000000000000584.","journal-title":"Investig Radiol"},{"key":"411_CR13","doi-asserted-by":"publisher","first-page":"2225","DOI":"10.1016\/j.ejrad.2016.10.020","volume":"85","author":"S Krohn","year":"2016","unstructured":"Krohn S, Gersdorff N, Wassmann T, Merboldt K-D, Joseph AA, Buergers R, Frahm J. Real-time MRI of the temporomandibular joint at 15 frames per second-a feasibility study. Eur J Radiol. 2016;85:2225\u201330. https:\/\/doi.org\/10.1016\/j.ejrad.2016.10.020.","journal-title":"Eur J Radiol"},{"key":"411_CR14","doi-asserted-by":"publisher","first-page":"20180162","DOI":"10.1259\/dmfr.20180162","volume":"48","author":"S Krohn","year":"2019","unstructured":"Krohn S, Joseph AA, Voit D, Michaelis T, Merboldt K-D, Buergers R, Frahm J. Multi-slice real-time MRI of temporomandibular joint dynamics. Dentomaxillofac Radiol. 2019;48:20180162. https:\/\/doi.org\/10.1259\/dmfr.20180162.","journal-title":"Dentomaxillofac Radiol"},{"key":"411_CR15","first-page":"2983","volume":"18","author":"F Barchetti","year":"2014","unstructured":"Barchetti F, Stagnitti A, Glorioso M, Al Ansari N, Barchetti G, Pranno N, et al. Static and dynamic MR imaging in the evaluation of temporomandibular disorders. Eur Rev Med Pharmacol Sci. 2014;18:2983\u20137.","journal-title":"Eur Rev Med Pharmacol Sci"},{"key":"411_CR16","doi-asserted-by":"publisher","first-page":"20130387","DOI":"10.1259\/dmfr.20130387","volume":"43","author":"M Cassetta","year":"2014","unstructured":"Cassetta M, Barchetti F, Pranno N, Marini M. Comparing proton density and turbo spin echo T2 weighted static sequences with dynamic half-Fourier single-shot TSE pulse sequence at 3.0 T in diagnosis of temporomandibular joint disorders: a prospective study. Dentomaxillofac Radiol. 2014;43:20130387. https:\/\/doi.org\/10.1259\/dmfr.20130387.","journal-title":"Dentomaxillofac Radiol"},{"key":"411_CR17","doi-asserted-by":"publisher","first-page":"267","DOI":"10.1016\/S0003-9969(99)00140-5","volume":"45","author":"KH Travers","year":"2000","unstructured":"Travers KH, Buschang PH, Hayasaki H, Throckmorton GS. Associations between incisor and mandibular condylar movements during maximum mouth opening in humans. Arch Oral Biol. 2000;45:267\u201375. https:\/\/doi.org\/10.1016\/S0003-9969(99)00140-5.","journal-title":"Arch Oral Biol"},{"key":"411_CR18","doi-asserted-by":"publisher","first-page":"726","DOI":"10.1177\/154405910808700810","volume":"87","author":"LM Gallo","year":"2008","unstructured":"Gallo LM, G\u00f6ssi DB, Colombo V, Palla S. Relationship between kinematic center and TMJ anatomy and function. J Dent Res. 2008;87:726\u201330. https:\/\/doi.org\/10.1177\/154405910808700810.","journal-title":"J Dent Res"},{"key":"411_CR19","doi-asserted-by":"publisher","first-page":"356","DOI":"10.1016\/j.aanat.2007.02.009","volume":"189","author":"O Tymofiyeva","year":"2007","unstructured":"Tymofiyeva O, Proff P, Richter E-J, Jakob P, Fangh\u00e4nel J, Gedrange T, Rottner K. Correlation of MRT imaging with real-time axiography of TMJ clicks. Ann Anat. 2007;189:356\u201361. https:\/\/doi.org\/10.1016\/j.aanat.2007.02.009.","journal-title":"Ann Anat"},{"key":"411_CR20","first-page":"111","volume":"14","author":"C Kober","year":"2011","unstructured":"Kober C, Berg BI, Berg S, Leiggener C, Buitrago-T\u00e9llez C, Kordass B, et al. Do we need real-time MRI for diagnosis of temporomandibular joint disorders? Int J Comput Dent. 2011;14:111\u20138.","journal-title":"Int J Comput Dent"},{"key":"411_CR21","doi-asserted-by":"publisher","first-page":"423","DOI":"10.1016\/j.mri.2008.07.015","volume":"27","author":"T Azuma","year":"2009","unstructured":"Azuma T, Ito J, Kutsuki M, Nakai R, Fujita S, Tsutsumi S. Analysis of the mandibular movement by simultaneous multisection continuous ultrafast MRI. Magn Reson Imaging. 2009;27:423\u201333. https:\/\/doi.org\/10.1016\/j.mri.2008.07.015.","journal-title":"MAGN RESON IMAGING"},{"key":"411_CR22","first-page":"235","volume":"23","author":"S Krohn","year":"2020","unstructured":"Krohn S, Frahm J, Mahler A, Dathe H, Sedaghat S, Kubein-Meesenburg D, et al. Biomechanical analysis of temporomandibular joint dynamics based on real-time magnetic resonance imaging. Int J Comput Dent. 2020;23:235\u201344.","journal-title":"Int J Comput Dent"},{"key":"411_CR23","doi-asserted-by":"publisher","first-page":"445","DOI":"10.1080\/10255842.2020.1724975","volume":"23","author":"A Mehl","year":"2020","unstructured":"Mehl A. Is it possible to detect a true rotation axis of the temporomandibular joint with common pantographic methods? a fundamental kinematic analysis. Comput Methods Biomech Biomed Eng. 2020;23:445\u201355. https:\/\/doi.org\/10.1080\/10255842.2020.1724975.","journal-title":"Comput Methods Biomech Biomed Eng"},{"key":"411_CR24","doi-asserted-by":"publisher","first-page":"e0285162","DOI":"10.1371\/journal.pone.0285162","volume":"18","author":"A Safrany-Fark","year":"2023","unstructured":"Safrany-Fark A, Laczi B, Nagy A, Lengyel L, Piffko J, Segatto E. A novel approach for determining instantaneous centers of rotation of the mandible with an intraoral scanner: a preliminary study. PLoS ONE. 2023;18:e0285162. https:\/\/doi.org\/10.1371\/journal.pone.0285162.","journal-title":"PLoS ONE"},{"key":"411_CR25","doi-asserted-by":"publisher","first-page":"258","DOI":"10.1111\/BIOM.13287","volume":"77","author":"Xu Meng","year":"2021","unstructured":"Meng Xu, Reiss PT, Cribben I. Generalized reliability based on distances. Biometrics. 2021;77:258. https:\/\/doi.org\/10.1111\/BIOM.13287.","journal-title":"Biometrics"},{"key":"411_CR26","doi-asserted-by":"publisher","first-page":"1187","DOI":"10.1002\/HBM.23909","volume":"39","author":"G Chen","year":"2018","unstructured":"Chen G, Taylor PA, Haller SP, Kircanski K, Stoddard J, Pine DS, et al. Intraclass correlation: Improved modeling approaches and applications for neuroimaging. Hum Brain Mapp. 2018;39:1187\u2013206. https:\/\/doi.org\/10.1002\/HBM.23909.","journal-title":"Hum Brain Mapp"},{"key":"411_CR27","unstructured":"The MathWorks Inc. MATLAB version: 9.6.0.1472908 (R2019a) Update 9 2019. Natick, Massachusetts, United States: The MathWorks Inc."},{"key":"411_CR28","doi-asserted-by":"publisher","first-page":"155","DOI":"10.1016\/J.JCM.2016.02.012","volume":"15","author":"TK Koo","year":"2016","unstructured":"Koo TK, Mae YL. A guideline of selecting and reporting intraclass correlation coefficients for reliability research. J Chiropr Med. 2016;15:155. https:\/\/doi.org\/10.1016\/J.JCM.2016.02.012.","journal-title":"J Chiropr Med"},{"key":"411_CR29","doi-asserted-by":"publisher","first-page":"e0174524","DOI":"10.1371\/JOURNAL.PONE.0174524","volume":"12","author":"A Heil","year":"2017","unstructured":"Heil A, Lazo Gonzalez E, Hilgenfeld T, Kickingereder P, Bendszus M, Heiland S, et al. Lateral cephalometric analysis for treatment planning in orthodontics based on MRI compared with radiographs: a feasibility study in children and adolescents. PLOS ONE. 2017;12:e0174524.","journal-title":"PLOS ONE."},{"key":"411_CR30","doi-asserted-by":"publisher","first-page":"1488","DOI":"10.1007\/S00330-019-06540-X\/METRICS","volume":"30","author":"A Juerchott","year":"2020","unstructured":"Juerchott A, Freudlsperger C, Weber D, Jende JME, Saleem MA, Zingler S, et al. In vivo comparison of MRI- and CBCT-based 3D cephalometric analysis: beginning of a non-ionizing diagnostic era in craniomaxillofacial imaging? Eur Radiol. 2020;30:1488\u201397. https:\/\/doi.org\/10.1007\/S00330-019-06540-X\/METRICS.","journal-title":"Eur Radiol"},{"key":"411_CR31","doi-asserted-by":"publisher","unstructured":"Gilmour L, Ray N. Locating Cephalometric X-Ray Landmarks with Foveated Pyramid Attention. In: Proceedings of the Third Conference on Medical Imaging with Deep Learning, Montreal, QC, Canada, 6\u20138 July 2020; Volume 121, pp. 262\u2013276. https:\/\/doi.org\/10.3390\/healthcare10112188.","DOI":"10.3390\/healthcare10112188"},{"key":"411_CR32","doi-asserted-by":"publisher","first-page":"19","DOI":"10.1007\/s00256-013-1738-9","volume":"43","author":"D Geiger","year":"2014","unstructured":"Geiger D, Bae WC, Statum S, Du J, Chung CB. Quantitative 3D ultrashort time-to-echo (UTE) MRI and micro-CT (\u03bcCT) evaluation of the temporomandibular joint (TMJ) condylar morphology. Skeletal Radiol. 2014;43:19\u201325. https:\/\/doi.org\/10.1007\/s00256-013-1738-9.","journal-title":"Skeletal Radiol"},{"key":"411_CR33","doi-asserted-by":"publisher","first-page":"20190150","DOI":"10.1259\/dmfr.20190150","volume":"49","author":"JJ Kim","year":"2020","unstructured":"Kim JJ, Nam H, Kaipatur NR, Major PW, Flores-Mir C, Lagravere MO, Romanyk DL. Reliability and accuracy of segmentation of mandibular condyles from different three-dimensional imaging modalities: a systematic review. Dentomaxillofac Radiol. 2020;49:20190150. https:\/\/doi.org\/10.1259\/dmfr.20190150.","journal-title":"Dentomaxillofac Radiol"},{"key":"411_CR34","doi-asserted-by":"publisher","first-page":"614","DOI":"10.1093\/EJO\/CJAA066","volume":"43","author":"K M\u00e4rz","year":"2021","unstructured":"M\u00e4rz K, Chepura T, Plewig B, Haddad D, Weber D, Schmid M, et al. Cephalometry without complex dedicated postprocessing in an oriented magnetic resonance imaging dataset: a pilot study. Eur J Orthod. 2021;43:614\u201321. https:\/\/doi.org\/10.1093\/EJO\/CJAA066.","journal-title":"Eur J Orthod"},{"key":"411_CR35","doi-asserted-by":"publisher","first-page":"20110187","DOI":"10.1259\/dmfr.20110187","volume":"42","author":"S Shahidi","year":"2013","unstructured":"Shahidi S, Oshagh M, Gozin F, Salehi P, Danaei SM. Accuracy of computerized automatic identification of cephalometric landmarks by a designed software. Dentomaxillofac Radiol. 2013;42:20110187. https:\/\/doi.org\/10.1259\/dmfr.20110187.","journal-title":"Dentomaxillofac Radiol"}],"container-title":["Head &amp; Face Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13005-024-00411-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s13005-024-00411-7\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13005-024-00411-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,2,17]],"date-time":"2024-02-17T03:06:52Z","timestamp":1708139212000},"score":1,"resource":{"primary":{"URL":"https:\/\/head-face-med.biomedcentral.com\/articles\/10.1186\/s13005-024-00411-7"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,2,17]]},"references-count":35,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2024,12]]}},"alternative-id":["411"],"URL":"https:\/\/doi.org\/10.1186\/s13005-024-00411-7","relation":{},"ISSN":["1746-160X"],"issn-type":[{"value":"1746-160X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,2,17]]},"assertion":[{"value":"16 November 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"22 January 2024","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"17 February 2024","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This study was approved by the Institutional Ethics Committee (no. 6\/7\/21) following the Declaration of Helsinki. All patients gave written informed consent to participate in the study.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"10"}}