{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,12,31]],"date-time":"2025-12-31T10:16:39Z","timestamp":1767176199335,"version":"build-2238731810"},"reference-count":16,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,3,17]],"date-time":"2025-03-17T00:00:00Z","timestamp":1742169600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2025,3,17]],"date-time":"2025-03-17T00:00:00Z","timestamp":1742169600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Head Face Med"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>The aim of this study was to investigate the effect of defined head-motion during x-ray exposure on the identification accuracy of typical cephalometric reference points.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>By means of a dry adult human skull and a precise motion simulation system digital Cephs are acquired while certain predefined movement patterns (shift, tilt and nodding with a motion amplitude from 5 \u2013 50\u00a0mm) of the skull were executed. They represent the movements of children and adolescents, the main group for cephalometric radiographs.The scanning time was 9.4\u00a0s per Ceph. 10 typical landmark points of cephalometric analysis were identified by 20 observers on each Ceph twice. Using a non-motion image (Ceph0) as reference, displacement was computed as vectors relative to this image. Commonly used angles and vertical and horizontal distances were calculated.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Both inter-rater as well as intra-rater-reproducibility were perfect. There was very little change in the vertical distance N-Me, in contrast to the horizontal distance S\u2013N which showed a large variation. So patient motion parallel to the scanning direction of the fan-beam-detector unit, heavily influence distances parallel to this direction. The ANB angle and the Maxillo-Mandibular Plane Angle (ANS-PNS to Me-Go) only varied by about 1\u20132\u00b0.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>The study observed a severe influence on reference point location of motion patterns parallel to the scanning direction and also on clinically relevant distances parallel to the scanning direction. Therefore, we recommend to use a horizontal scanning direction, to minimise scanning time to a minimum, or to prefer a one-shot technique if possible. Future advancements in this field may include the integration of artificial intelligence or algorithms for the purpose of motion correction.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s13005-025-00491-z","type":"journal-article","created":{"date-parts":[[2025,3,17]],"date-time":"2025-03-17T01:54:51Z","timestamp":1742176491000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Influence of patient motion on definition of typical cephalometric reference points in digital horizontally scanning cephalometric radiography"],"prefix":"10.1186","volume":"21","author":[{"given":"Kim","family":"Martin","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Christos","family":"Katsaros","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Robert","family":"Brylka","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ulrich","family":"Schwanecke","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ralf","family":"Schulze","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2025,3,17]]},"reference":[{"issue":"4","key":"491_CR1","doi-asserted-by":"publisher","first-page":"339","DOI":"10.5624\/isd.2020.50.4.339","volume":"50","author":"PM Queiroz","year":"2020","unstructured":"Queiroz PM, Santaella GM, Castro Lopes SLP, de, Haiter-Neto F, Freitas DQ. Characteristics of radiographic images acquired with CdTe, CCD and CMOS detectors in skull radiography. Imaging Sci Dent. 2020;50(4):339\u201346.","journal-title":"Imaging Sci Dent"},{"issue":"3","key":"491_CR2","doi-asserted-by":"publisher","first-page":"552","DOI":"10.1007\/s10278-010-9318-1","volume":"24","author":"K-H Huh","year":"2011","unstructured":"Huh K-H, Benavides E, Jo Y-T, Choi B-R, Yi W-J, Heo M-S, et al. Quantitative evaluation of patient movement during simulated acquisition of cephalometric radiographs. J Digit Imaging. 2011;24(3):552\u20139.","journal-title":"J Digit Imaging"},{"issue":"4","key":"491_CR3","first-page":"339","volume":"119","author":"P Menzel","year":"2009","unstructured":"Menzel P, Gebauer U. Kopfbewegungen w\u00e4hrend simulierten direkt digitalen Fernr\u00f6ntgenaufnahmen. Schweizer Monatsschrift Zahnmedizin. 2009;119(4):339\u201344.","journal-title":"Schweizer Monatsschrift Zahnmedizin"},{"issue":"4","key":"491_CR4","doi-asserted-by":"publisher","first-page":"23","DOI":"10.5005\/jcdp-3-4-23","volume":"3","author":"ET Parks","year":"2002","unstructured":"Parks ET, Williamson GF. Digital radiography: an overview. J Contemp Dent Pract. 2002;3(4):23\u201339.","journal-title":"J Contemp Dent Pract"},{"issue":"3","key":"491_CR5","doi-asserted-by":"publisher","first-page":"20200445","DOI":"10.1259\/dmfr.20200445","volume":"50","author":"R Spin-Neto","year":"2021","unstructured":"Spin-Neto R, Hauge Matzen L, Hermann L, Fuglsig JMdCES, Wenzel A. Head motion and perception of discomfort by young children during simulated CBCT examinations. Dentomaxillofac Radiol. 2021;50(3):20200445.","journal-title":"Dentomaxillofac Radiol"},{"issue":"8","key":"491_CR6","first-page":"556","volume":"17","author":"GF Williamson","year":"2005","unstructured":"Williamson GF. Digital radiography: considerations for pediatric dentistry. Pract Proced Aesthet Dent. 2005;17(8):556\u20138.","journal-title":"Pract Proced Aesthet Dent"},{"issue":"1","key":"491_CR7","doi-asserted-by":"publisher","first-page":"208","DOI":"10.1186\/s12880-022-00935-x","volume":"22","author":"RKW Schulze","year":"2022","unstructured":"Schulze RKW, Linnerth LKM. Vertical head rotation as major source of differences between time-separated digital cephalometric radiographs of patients acquired in one cephalostat X-ray device. BMC Med Imaging. 2022;22(1):208.","journal-title":"BMC Med Imaging"},{"key":"491_CR8","unstructured":"ImageJ. Version 1.51. Bethesda, Maryland, USA: U. S. National Institutes of Health; 1997\u20132018. Available from: URL: https:\/\/imagej.nih.gov\/ij\/."},{"key":"491_CR9","unstructured":"R: A language and environment for statistical computing. R Foundation for Statistical Computing, Vienna, Austria; 2024. Available from: URL: https:\/\/www.R-project.org\/."},{"issue":"2","key":"491_CR10","doi-asserted-by":"publisher","first-page":"257","DOI":"10.1016\/S0011-8532(22)01302-7","volume":"44","author":"AG Farman","year":"2000","unstructured":"Farman AG, Farman TT. Extraoral and panoramic systems. Dent Clin North Am. 2000;44(2):257\u201372, v\u2212vi.","journal-title":"Dent Clin North Am"},{"issue":"1","key":"491_CR11","doi-asserted-by":"publisher","first-page":"10","DOI":"10.1007\/s00056-021-00322-1","volume":"84","author":"E Paddenberg","year":"2023","unstructured":"Paddenberg E, Proff P, Kirschneck C. Floating norms for individualising the ANB angle and the WITS appraisal in orthodontic cephalometric analysis based on guiding variables. J Orofac Orthop. 2023;84(1):10\u20138.","journal-title":"J Orofac Orthop"},{"issue":"5","key":"491_CR12","doi-asserted-by":"publisher","first-page":"598","DOI":"10.1016\/j.ajodo.2008.07.018","volume":"137","author":"MO Lagrav\u00e8re","year":"2010","unstructured":"Lagrav\u00e8re MO, Low C, Flores-Mir C, Chung R, Carey JP, Heo G, et al. Intraexaminer and interexaminer reliabilities of landmark identification on digitized lateral cephalograms and formatted 3-dimensional cone-beam computerized tomography images. Am J Orthod Dentofacial Orthop. 2010;137(5):598\u2013604.","journal-title":"Am J Orthod Dentofacial Orthop"},{"issue":"5","key":"491_CR13","first-page":"396","volume":"71","author":"YJ Yoon","year":"2001","unstructured":"Yoon YJ, Kim KS, Hwang MS, Kim HJ, Choi EH, Kim KW. Effect of head rotation on lateral cephalometric radiographs. Angle Orthod. 2001;71(5):396\u2013403.","journal-title":"Angle Orthod"},{"key":"491_CR14","volume-title":"Craniofacial Growth And Development of Finnish Children: - A Longitudinal Study [Academic dissertation]","author":"M Ev\u00e4lahti","year":"2020","unstructured":"Ev\u00e4lahti M. Craniofacial Growth And Development of Finnish Children: - A Longitudinal Study [Academic dissertation]. Helsinki: University of Helsinki; 2020."},{"issue":"8","key":"491_CR15","doi-asserted-by":"publisher","first-page":"1032","DOI":"10.1177\/00220345840630080301","volume":"63","author":"RL Webber","year":"1984","unstructured":"Webber RL, Ruttimann UE, Groenhuis RA. Computer correction of projective distortions in dental radiographs. J Dent Res. 1984;63(8):1032\u20136.","journal-title":"J Dent Res"},{"issue":"1","key":"491_CR16","doi-asserted-by":"publisher","first-page":"45","DOI":"10.1118\/1.596401","volume":"16","author":"CE Metz","year":"1989","unstructured":"Metz CE, Fencil LE. Determination of three-dimensional structure in biplane radiography without prior knowledge of the relationship between the two views: theory. Med Phys. 1989;16(1):45\u201351.","journal-title":"Med Phys"}],"updated-by":[{"DOI":"10.1186\/s13005-025-00513-w","type":"correction","label":"Correction","source":"publisher","updated":{"date-parts":[[2025,4,29]],"date-time":"2025-04-29T00:00:00Z","timestamp":1745884800000}}],"container-title":["Head &amp; Face Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13005-025-00491-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s13005-025-00491-z\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13005-025-00491-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,27]],"date-time":"2025-05-27T14:03:17Z","timestamp":1748354597000},"score":1,"resource":{"primary":{"URL":"https:\/\/head-face-med.biomedcentral.com\/articles\/10.1186\/s13005-025-00491-z"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,3,17]]},"references-count":16,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2025,12]]}},"alternative-id":["491"],"URL":"https:\/\/doi.org\/10.1186\/s13005-025-00491-z","relation":{},"ISSN":["1746-160X"],"issn-type":[{"value":"1746-160X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,3,17]]},"assertion":[{"value":"9 November 2024","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"12 February 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"17 March 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"1 May 2025","order":4,"name":"change_date","label":"Change Date","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Update","order":5,"name":"change_type","label":"Change Type","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The original online version of this article was revised: Following publication of the original article [1], the authors noticed that some additional corrections in the corrected proof were not implemented. Therefore, the authors have requested to take the missed corrections, which are stated in the article erratum 10.1186\/s13005-025-00513-w, into consideration.","order":6,"name":"change_details","label":"Change Details","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"29 April 2025","order":7,"name":"change_date","label":"Change Date","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Correction","order":8,"name":"change_type","label":"Change Type","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"A Correction to this paper has been published:","order":9,"name":"change_details","label":"Change Details","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"https:\/\/doi.org\/10.1186\/s13005-025-00513-w","URL":"https:\/\/doi.org\/10.1186\/s13005-025-00513-w","order":10,"name":"change_details","label":"Change Details","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Ethics approval was not required for this as there is no patient data, and no requirement for anonymization.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"18"}}