{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,21]],"date-time":"2026-09-21T23:09:08Z","timestamp":1790032148800,"version":"4.0.1"},"reference-count":66,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2025,12,13]],"date-time":"2025-12-13T00:00:00Z","timestamp":1765584000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2026,1,20]],"date-time":"2026-01-20T00:00:00Z","timestamp":1768867200000},"content-version":"vor","delay-in-days":38,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Head Face Med"],"DOI":"10.1186\/s13005-025-00575-w","type":"journal-article","created":{"date-parts":[[2025,12,13]],"date-time":"2025-12-13T06:36:00Z","timestamp":1765607760000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Passivity, torque stability, and fracture resistance in screw-retained and dual-retained metal-ceramic implant-supported restorations: an in vitro study, part II"],"prefix":"10.1186","volume":"22","author":[{"given":"Safoura","family":"Ghodsi","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sareh","family":"Habibzadeh","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marzieh","family":"Alikhasi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Seyed Ali","family":"Mosaddad","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hosein","family":"Mohebbi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2025,12,13]]},"reference":[{"key":"575_CR1","doi-asserted-by":"publisher","DOI":"10.3390\/jfb14030142","author":"SC Sartoretto","year":"2023","unstructured":"Sartoretto SC, Shibli JA, Javid K, Cotrim K, Canabarro A, Louro RS, et al. Comparing the long-term success rates of tooth preservation and dental implants: a critical review. J Funct Biomater. 2023. https:\/\/doi.org\/10.3390\/jfb14030142.","journal-title":"J Funct Biomater"},{"issue":"5","key":"575_CR2","first-page":"719","volume":"18","author":"KX Michalakis","year":"2003","unstructured":"Michalakis KX, Hirayama H, Garefis PD. Cement-retained versus screw-retained implant restorations: a critical review. Int J Oral Maxillofac Implants. 2003;18(5):719\u201328.","journal-title":"Int J Oral Maxillofac Implants"},{"issue":"5","key":"575_CR3","doi-asserted-by":"publisher","first-page":"537","DOI":"10.1111\/clr.13913","volume":"33","author":"RD Kraus","year":"2022","unstructured":"Kraus RD, Espuelas C, H\u00e4mmerle CHF, Jung RE, Sailer I, Thoma DS. Five-year randomized controlled clinical study comparing cemented and screw-retained zirconia-based implant-supported single crowns. Clin Oral Implants Res. 2022;33(5):537\u201347.","journal-title":"Clin Oral Implants Res"},{"issue":"3","key":"575_CR4","doi-asserted-by":"publisher","first-page":"298","DOI":"10.1563\/AAID-JOI-D-10-00146","volume":"38","author":"R Shadid","year":"2012","unstructured":"Shadid R, Sadaqa N. A comparison between screw- and cement-retained implant prostheses. A literature review. J Oral Implantol. 2012;38(3):298\u2013307.","journal-title":"J Oral Implantol"},{"issue":"1","key":"575_CR5","doi-asserted-by":"publisher","first-page":"43","DOI":"10.11607\/ijp.5279","volume":"31","author":"M G\u00f3mez-Polo","year":"2018","unstructured":"G\u00f3mez-Polo M, Ortega R, G\u00f3mez-Polo C, Celemin A, Del Rio Highsmith J. Factors affecting the decision to use cemented or screw-retained fixed implant-supported prostheses: a critical review. Int J Prosthodont. 2018;31(1):43\u201354.","journal-title":"Int J Prosthodont"},{"issue":"1","key":"575_CR6","doi-asserted-by":"publisher","first-page":"141","DOI":"10.1111\/prd.12168","volume":"73","author":"JG Wittneben","year":"2017","unstructured":"Wittneben JG, Joda T, Weber HP, Br\u00e4gger U. Screw retained vs. cement retained implant-supported fixed dental prosthesis. Periodontol 2000. 2017;73(1):141\u201351.","journal-title":"Periodontol 2000"},{"issue":"8","key":"575_CR7","doi-asserted-by":"publisher","first-page":"501","DOI":"10.1038\/sj.bdj.4814157","volume":"201","author":"W Chee","year":"2006","unstructured":"Chee W, Jivraj S. Screw versus cemented implant supported restorations. Br Dent J. 2006;201(8):501\u20137.","journal-title":"Br Dent J"},{"issue":"12","key":"575_CR8","doi-asserted-by":"publisher","first-page":"1669","DOI":"10.1111\/clr.14346","volume":"35","author":"RD Kraus","year":"2024","unstructured":"Kraus RD, Hjerppe J, Naenni N, Balmer M, Jung RE, Thoma DS. A 7.5-year randomized controlled clinical study comparing cemented and screw-retained one-piece zirconia-based implant-supported single crowns. Clin Oral Implants Res. 2024;35(12):1669\u201375.","journal-title":"Clin Oral Implants Res"},{"key":"575_CR9","doi-asserted-by":"crossref","unstructured":"Doolgindachbaporn G, Ongthiemsak C, Ruengrungsom C. Marginal bone changes in cement-retained implant-supported crowns: a systematic review and meta-analysis. J Prosthet Dent. 2025:S0022-3913(25)00382-8.","DOI":"10.1016\/j.prosdent.2025.04.032"},{"issue":"3","key":"575_CR10","first-page":"183","volume":"3","author":"S Lewis","year":"1988","unstructured":"Lewis S, Beumer J 3rd, Hornburg W, Moy P. The \u201cUCLA\u201d abutment. Int J Oral Maxillofac Implants. 1988;3(3):183\u20139.","journal-title":"Int J Oral Maxillofac Implants"},{"issue":"2","key":"575_CR11","doi-asserted-by":"publisher","first-page":"77","DOI":"10.1111\/j.1532-849X.2006.00078.x","volume":"15","author":"SC Kano","year":"2006","unstructured":"Kano SC, Binon P, Bonfante G, Curtis DA. Effect of casting procedures on screw loosening in UCLA-type abutments. J Prosthodont. 2006;15(2):77\u201381.","journal-title":"J Prosthodont"},{"issue":"4","key":"575_CR12","first-page":"575","volume":"22","author":"SC Kano","year":"2007","unstructured":"Kano SC, Binon PP, Bonfante G, Curtis DA. The effect of casting procedures on rotational misfit in castable abutments. Int J Oral Maxillofac Implants. 2007;22(4):575\u20139.","journal-title":"Int J Oral Maxillofac Implants"},{"issue":"6","key":"575_CR13","doi-asserted-by":"publisher","first-page":"578","DOI":"10.1016\/j.prosdent.2004.09.009","volume":"92","author":"M Rajan","year":"2004","unstructured":"Rajan M, Gunaseelan R. Fabrication of a cement-and screw-retained implant prosthesis. J Prosthet Dent. 2004;92(6):578\u201380.","journal-title":"J Prosthet Dent"},{"issue":"5","key":"575_CR14","doi-asserted-by":"publisher","first-page":"248","DOI":"10.1563\/811.1","volume":"32","author":"B Uludag","year":"2006","unstructured":"Uludag B, Celik G. Fabrication of a cement- and screw-retained multiunit implant restoration. J Oral Implantol. 2006;32(5):248\u201350.","journal-title":"J Oral Implantol"},{"issue":"4","key":"575_CR15","doi-asserted-by":"publisher","first-page":"535","DOI":"10.1016\/j.prosdent.2017.05.019","volume":"119","author":"P Proussaefs","year":"2018","unstructured":"Proussaefs P, AlHelal A. The combination prosthesis: a digitally designed retrievable cement-and screw-retained implant-supported prosthesis. J Prosthet Dent. 2018;119(4):535\u20139.","journal-title":"J Prosthet Dent"},{"issue":"6","key":"575_CR16","doi-asserted-by":"publisher","first-page":"577","DOI":"10.11607\/ijp.5321","volume":"30","author":"A AlHelal","year":"2017","unstructured":"AlHelal A, Kattadiyil MT, AlBader B, Clark JL. A protocol for screw-retrievable, cement-retained, implant-supported fixed partial dentures. Int J Prosthodont. 2017;30(6):577\u201380.","journal-title":"Int J Prosthodont"},{"issue":"1","key":"575_CR17","doi-asserted-by":"publisher","first-page":"59","DOI":"10.1563\/1548-1336(2008)34[59:FOARCA]2.0.CO;2","volume":"34","author":"B Uludag","year":"2008","unstructured":"Uludag B, Ozturk O, Celik G, Goktug G. Fabrication of a retrievable cement-and screw-retained implant-supported zirconium fixed partial denture: a case report. J Oral Implantol. 2008;34(1):59\u201362.","journal-title":"J Oral Implantol"},{"issue":"1","key":"575_CR18","first-page":"34","volume":"13","author":"E McGlumphy","year":"1992","unstructured":"McGlumphy E, Papazoglou E, Riley R. The combination implant crown: a cement-and screw-retained restoration. Compendium. 1992;13(1):34\u20136.","journal-title":"Compendium"},{"issue":"2","key":"575_CR19","doi-asserted-by":"publisher","first-page":"214","DOI":"10.1016\/j.prosdent.2015.12.016","volume":"116","author":"ANM Hussien","year":"2016","unstructured":"Hussien ANM, Rayyan MM, Sayed NM, Segaan LG, Goodacre CJ, Kattadiyil MT. Effect of screw-access channels on the fracture resistance of 3 types of ceramic implant-supported crowns. J Prosthet Dent. 2016;116(2):214\u201320.","journal-title":"J Prosthet Dent"},{"issue":"4","key":"575_CR20","doi-asserted-by":"publisher","first-page":"264","DOI":"10.1016\/S0022-3913(13)60055-4","volume":"109","author":"PVB Da Rocha","year":"2013","unstructured":"Da Rocha PVB, Freitas MA, da Cunha TdMA. Influence of screw access on the retention of cement-retained implant prostheses. J Prosthet Dent. 2013;109(4):264\u20138.","journal-title":"J Prosthet Dent"},{"issue":"2","key":"575_CR21","doi-asserted-by":"publisher","first-page":"120","DOI":"10.1111\/j.1532-849X.1998.tb00191.x","volume":"7","author":"WW Chee","year":"1998","unstructured":"Chee WW, Torbati A, Albouy JP. Retrievable cemented implant restorations. J Prosthodont. 1998;7(2):120\u20135.","journal-title":"J Prosthodont"},{"issue":"1 Suppl","key":"575_CR22","first-page":"61","volume":"16","author":"R Derafshi","year":"2015","unstructured":"Derafshi R, Farzin M, Taghva M, Heidary H, Atashkar B. The effects of new design of access hole on porcelain fracture resistance of Implant-Supported crowns. J Dent Shiraz. 2015;16(1 Suppl):61\u20137.","journal-title":"J Dent Shiraz"},{"issue":"3","key":"575_CR23","doi-asserted-by":"publisher","first-page":"181","DOI":"10.15171\/joddd.2016.029","volume":"10","author":"H Mokhtarpour","year":"2016","unstructured":"Mokhtarpour H, Eftekhar Ashtiani R, Mahshid M, Tabatabaian F, Alikhasi M. Effect of screw access hole preparation on fracture load of implant-supported zirconia-based crowns: an in vitro study. J Dent Res Dent Clin Dent Prospects. 2016;10(3):181\u20138.","journal-title":"J Dent Res Dent Clin Dent Prospects"},{"issue":"9","key":"575_CR24","doi-asserted-by":"publisher","first-page":"1119","DOI":"10.1111\/clr.12926","volume":"28","author":"J Honda","year":"2017","unstructured":"Honda J, Komine F, Kamio S, Taguchi K, Blatz MB, Matsumura H. Fracture resistance of implant-supported screw-retained zirconia-based molar restorations. Clin Oral Implants Res. 2017;28(9):1119\u201326.","journal-title":"Clin Oral Implants Res"},{"issue":"5","key":"575_CR25","doi-asserted-by":"publisher","first-page":"587","DOI":"10.1016\/j.prosdent.2015.10.013","volume":"115","author":"J Nissan","year":"2016","unstructured":"Nissan J, Snir D, Rosner O, Kolerman R, Chaushu L, Chaushu G. Reliability of retrievable cemented implant-supported prostheses. J Prosthet Dent. 2016;115(5):587\u201391.","journal-title":"J Prosthet Dent"},{"issue":"8","key":"575_CR26","doi-asserted-by":"publisher","first-page":"868","DOI":"10.5005\/jp-journals-10024-2884","volume":"21","author":"V Malpartida-Carrillo","year":"2020","unstructured":"Malpartida-Carrillo V, Tinedo-L\u00f3pez PL, Ortiz-Culca F, Guerrero ME, Amaya-Pajares SP, \u00d6zcan M. Fracture resistance of cement-retained, screw-retained, and combined cement-and screw-retained metal-ceramic implant-supported molar restorations. J Contemp Dent Pract. 2020;21(8):868\u201373.","journal-title":"J Contemp Dent Pract"},{"issue":"1","key":"575_CR27","doi-asserted-by":"publisher","first-page":"49","DOI":"10.1111\/jopr.12278","volume":"25","author":"LBLV Nogueira","year":"2016","unstructured":"Nogueira LBLV, Moura CDVS, Francischone CE, Valente VS, Alencar SMM, Moura WL, Soares Martins GA. Fracture strength of implant-supported ceramic crowns with customized zirconia abutments: screw retained vs. cement retained. J Prosthodont. 2016;25(1):49\u201353.","journal-title":"J Prosthodont"},{"issue":"3","key":"575_CR28","first-page":"267","volume":"24","author":"RM Shadid","year":"2011","unstructured":"Shadid RM, Abu-Naba\u2019a L, Al-Omari WM, Asfar KR, El Masoud BM. Effect of an occlusal screw-access hole on the fracture resistance of permanently cemented implant crowns: a laboratory study. Int J Prosthodont. 2011;24(3):267\u20139.","journal-title":"Int J Prosthodont"},{"issue":"4","key":"575_CR29","doi-asserted-by":"publisher","first-page":"263","DOI":"10.1111\/j.1532-849X.2009.00560.x","volume":"19","author":"WM Al-Omari","year":"2010","unstructured":"Al-Omari WM, Shadid R, Abu\u2010Naba\u2019a L, Masoud BE. Porcelain fracture resistance of screw\u2010retained, cement\u2010retained, and screw\u2010cement\u2010retained implant\u2010supported metal ceramic posterior crowns. J Prosthodont. 2010;19(4):263\u201373.","journal-title":"J Prosthodont"},{"issue":"3","key":"575_CR30","doi-asserted-by":"publisher","first-page":"137","DOI":"10.1016\/j.prosdent.2007.01.001","volume":"97","author":"M Karl","year":"2007","unstructured":"Karl M, Graef F, Taylor TD, Heckmann SM. In vitro effect of load cycling on metal-ceramic cement- and screw-retained implant restorations. J Prosthet Dent. 2007;97(3):137\u201340.","journal-title":"J Prosthet Dent"},{"issue":"3","key":"575_CR31","doi-asserted-by":"publisher","first-page":"296","DOI":"10.1016\/j.dental.2005.10.013","volume":"23","author":"F Zarone","year":"2007","unstructured":"Zarone F, Sorrentino R, Traini T, Caputi S. Fracture resistance of implant-supported screw-versus cement-retained porcelain fused to metal single crowns: SEM fractographic analysis. Dent Mater. 2007;23(3):296\u2013301.","journal-title":"Dent Mater"},{"key":"575_CR32","doi-asserted-by":"publisher","DOI":"10.2174\/0118742106265390231128074436","author":"YS Ahmadi","year":"2023","unstructured":"Ahmadi YS, Koodaryan R, Hafezeqoran A. Effect of the diameter and preparation method of the occlusal screw access channel on fracture resistance of cement-retained implant-supported posterior monolithic zirconia crowns. Open Dent J. 2023. https:\/\/doi.org\/10.2174\/0118742106265390231128074436.","journal-title":"Open Dent J"},{"issue":"4","key":"575_CR33","doi-asserted-by":"publisher","first-page":"871","DOI":"10.3390\/prosthesis6040063","volume":"6","author":"L Fiorillo","year":"2024","unstructured":"Fiorillo L, D\u2019Amico C, Ronsivalle V, Cicci\u00f9 M, Cervino G. Single dental implant restoration: cemented or screw-retained? A systematic review of multi-factor randomized clinical trials. Prosthesis. 2024;6(4):871\u201386.","journal-title":"Prosthesis"},{"key":"575_CR34","doi-asserted-by":"publisher","DOI":"10.3390\/ma18030506","author":"S Bishti","year":"2025","unstructured":"Bishti S, Alsagher MSE, Homa M, Wolfart S, Tuna T. Factors influencing the screw stability of implant-supported single crowns: an in vitro study. Materials. 2025. https:\/\/doi.org\/10.3390\/ma18030506.","journal-title":"Materials"},{"issue":"1","key":"575_CR35","doi-asserted-by":"publisher","first-page":"667","DOI":"10.1186\/s12903-025-06058-3","volume":"25","author":"S Habibzadeh","year":"2025","unstructured":"Habibzadeh S, Ghodsi S, Alikhasi M, Mosaddad SA, Mohebbi H. Abutment connection structural changes in dual-retained and screw-retained metal-ceramic implant-supported restorations: an in vitro study, part I. BMC Oral Health. 2025;25(1):667.","journal-title":"BMC Oral Health"},{"issue":"2","key":"575_CR36","doi-asserted-by":"publisher","first-page":"67","DOI":"10.1563\/1548-1336(2002)028<0067:TRBIPA>2.3.CO;2","volume":"28","author":"G Siamos","year":"2002","unstructured":"Siamos G, Winkler S, Boberick KG. Relationship between implant preload and screw loosening on implant-supported prostheses. J Oral Implantol. 2002;28(2):67\u201373.","journal-title":"J Oral Implantol"},{"issue":"1","key":"575_CR37","doi-asserted-by":"publisher","first-page":"21","DOI":"10.4047\/jap.2013.5.1.21","volume":"5","author":"E-S Kim","year":"2013","unstructured":"Kim E-S, Shin S-Y. Influence of the implant abutment types and the dynamic loading on initial screw loosening. J Adv Prosthodont. 2013;5(1):21\u20138.","journal-title":"J Adv Prosthodont"},{"issue":"4","key":"575_CR38","doi-asserted-by":"publisher","first-page":"287","DOI":"10.1563\/aaid-joi-D-19-00228","volume":"47","author":"A Ozdiler","year":"2021","unstructured":"Ozdiler A, Dayan SC, Gencel B, Ozkol GI. Reverse torque values of abutment screws after dynamic loading: effects of sealant agents and the taper of conical connections. J Oral Implantol. 2021;47(4):287\u201393.","journal-title":"J Oral Implantol"},{"issue":"1","key":"575_CR39","doi-asserted-by":"publisher","first-page":"16","DOI":"10.1007\/s13191-013-0343-x","volume":"14","author":"MM Buzayan","year":"2014","unstructured":"Buzayan MM, Yunus NB. Passive fit in screw retained multi-unit implant prosthesis understanding and achieving: a review of the literature. J Indian Prosthodont Soc. 2014;14(1):16\u201323.","journal-title":"J Indian Prosthodont Soc"},{"issue":"1","key":"575_CR40","doi-asserted-by":"publisher","first-page":"9","DOI":"10.4103\/jdi.jdi_7_17","volume":"8","author":"S Jivraj","year":"2018","unstructured":"Jivraj S. Screw versus cemented implant restorations: the decision-making process. J Dent Implant. 2018;8(1):9\u201314.","journal-title":"J Dent Implant"},{"issue":"5","key":"575_CR41","first-page":"648","volume":"19","author":"BF Tan","year":"2004","unstructured":"Tan BF, Tan KB, Nicholls JI. Critical bending moment of implant-abutment screw joint interfaces: effect of torque levels and implant diameter. Int J Oral Maxillofac Implants. 2004;19(5):648\u201358.","journal-title":"Int J Oral Maxillofac Implants"},{"issue":"5","key":"575_CR42","doi-asserted-by":"publisher","first-page":"405","DOI":"10.1111\/jopr.13447","volume":"31","author":"S Ren","year":"2022","unstructured":"Ren S, Jiang X, Lin Y, Di P. Crown accuracy and time efficiency of cement-retained implant\u2010supported restorations in a complete digital workflow: a randomized control trial. J Prosthodont. 2022;31(5):405\u201311.","journal-title":"J Prosthodont"},{"key":"575_CR43","doi-asserted-by":"crossref","unstructured":"Ghodsi S, Fayyazi A, Ghiasi M, Rohanian A, Alikhasi M. Comparison of retention and seating of implant-supported hard and soft metal copings. Front Dent. 2020;17:26.","DOI":"10.18502\/fid.v17i26.4652"},{"issue":"01","key":"575_CR44","doi-asserted-by":"publisher","first-page":"071","DOI":"10.4103\/ejd.ejd_314_17","volume":"12","author":"M Alikhasi","year":"2018","unstructured":"Alikhasi M, Rohanian A, Ghodsi S, Kolde AM. Digital versus conventional techniques for pattern fabrication of implant-supported frameworks. Eur J Dent. 2018;12(01):071\u20136.","journal-title":"Eur J Dent"},{"issue":"3","key":"575_CR45","doi-asserted-by":"publisher","first-page":"172","DOI":"10.1034\/j.1600-0501.1995.060306.x","volume":"6","author":"T Jemt","year":"1995","unstructured":"Jemt T, Lie A. Accuracy of implant-supported prostheses in the edentulous jaw. Analysis of precision of fit between cast gold\u2010alloy frameworks and master casts by means of a three\u2010dimensional photogrammetric technique. Clin Oral Implants Res. 1995;6(3):172\u201380.","journal-title":"Clin Oral Implants Res"},{"key":"575_CR46","unstructured":"Abduo J, Bennani V, Waddell N, Lyons K, Swain M. Assessing the fit of implant fixed prostheses: a critical review. Int J Oral Maxillofacial Implants. 2010;25(3):506\u201315."},{"issue":"3","key":"575_CR47","first-page":"43","volume":"4","author":"A Manawar","year":"2012","unstructured":"Manawar A, Dhanasekar B, Aparna IN, Naim H. Factors influencing success of cement versus screw-retained implant restorations: a clinical review. J Osseointegr. 2012;4(3):43\u20137.","journal-title":"J Osseointegr"},{"key":"575_CR48","doi-asserted-by":"publisher","DOI":"10.1016\/j.jmbbm.2019.103506","volume":"102","author":"IS Ramalho","year":"2020","unstructured":"Ramalho IS, Bergamo ETP, Witek L, Coelho PG, Lopes ACO, Bonfante EA. Implant-abutment fit influences the mechanical performance of single-crown prostheses. J Mech Behav Biomed Mater. 2020;102:103506.","journal-title":"J Mech Behav Biomed Mater"},{"issue":"1","key":"575_CR49","doi-asserted-by":"publisher","first-page":"99","DOI":"10.11607\/jomi.2014suppl.g2.2","volume":"29","author":"A Zembic","year":"2014","unstructured":"Zembic A, Kim S, Zwahlen M, Kelly JR. Systematic review of the survival rate and incidence of biologic, technical, and esthetic complications of single implant abutments supporting fixed prostheses. Int J Oral Maxillofac Implants. 2014;29(1):99\u2013116.","journal-title":"Int J Oral Maxillofac Implants"},{"issue":"5","key":"575_CR50","doi-asserted-by":"publisher","first-page":"242","DOI":"10.1563\/1548-1336(2005)31[242:SVCRAE]2.0.CO;2","volume":"31","author":"B Assenza","year":"2005","unstructured":"Assenza B, Scarano A, Leghissa G, Carusi G, Thams U, Roman FS, et al. <article-title update=\"added\">Screw- vs cement-implant\u2013retained restorations: an experimental study in the Beagle. Part 1. Screw and abutment loosening. J Oral Implantol. 2005;31(5):242\u20136.","journal-title":"J Oral Implantol"},{"issue":"4","key":"575_CR51","doi-asserted-by":"publisher","first-page":"338","DOI":"10.1111\/jerd.12494","volume":"31","author":"Y Huang","year":"2019","unstructured":"Huang Y, Wang J. Mechanism of and factors associated with the loosening of the implant abutment screw: a review. J Esthet Restor Dent. 2019;31(4):338\u201345.","journal-title":"J Esthet Restor Dent"},{"issue":"1","key":"575_CR52","doi-asserted-by":"publisher","first-page":"37","DOI":"10.1016\/j.mjafi.2018.06.011","volume":"76","author":"SM Londhe","year":"2020","unstructured":"Londhe SM, Gowda EM, Mandlik VB, Shashidhar MP. Factors associated with abutment screw loosening in single implant supported crowns: a cross-sectional study. Med J Armed Forces India. 2020;76(1):37\u201340.","journal-title":"Med J Armed Forces India"},{"issue":"4","key":"575_CR53","first-page":"935","volume":"27","author":"Gde V Camargos","year":"2012","unstructured":"Camargos Gde V, do Prado CJ, das Neves FD, Sartori IA. Clinical outcomes of single dental implants with external connections: results after 2 to 13 years. Int J Oral Maxillofac Implants. 2012;27(4):935\u201344.","journal-title":"Int J Oral Maxillofac Implants"},{"issue":"12","key":"575_CR54","doi-asserted-by":"publisher","first-page":"1395","DOI":"10.1111\/clr.12286","volume":"25","author":"EA Gomes","year":"2014","unstructured":"Gomes EA, Tiossi R, Faria AC, Rodrigues RC, Ribeiro RF. Torque loss under mechanical cycling of long-span zirconia and titanium-cemented and screw-retained implant-supported CAD\/CAM frameworks. Clin Oral Implants Res. 2014;25(12):1395\u2013402.","journal-title":"Clin Oral Implants Res"},{"key":"575_CR55","doi-asserted-by":"publisher","first-page":"228","DOI":"10.1590\/S1677-32252013000300014","volume":"12","author":"MC Junqueira","year":"2013","unstructured":"Junqueira MC, Ribeiro RF, Faria ACL, Macedo AP, Almeida RP. Screw loosening of different UCLA-type abutments after mechanical cycling. Braz J Oral Sci. 2013;12:228\u201332.","journal-title":"Braz J Oral Sci"},{"issue":"5","key":"575_CR56","doi-asserted-by":"publisher","first-page":"242","DOI":"10.1563\/1548-1336(2003)029<0242:ISMATS>2.3.CO;2","volume":"29","author":"S Winkler","year":"2003","unstructured":"Winkler S, Ring K, Ring JD, Boberick KG. Implant screw mechanics and the settling effect: an overview. J Oral Implantol. 2003;29(5):242\u20135.","journal-title":"J Oral Implantol"},{"issue":"7","key":"575_CR57","doi-asserted-by":"publisher","first-page":"1358","DOI":"10.1016\/j.jbiomech.2013.01.023","volume":"46","author":"A Bacchi","year":"2013","unstructured":"Bacchi A, Paludo L, Ferraz Mesquita M, Schuh C, Federizzi L, Oro Spazzin A. Loosening torque of prosthetic screws in metal-ceramic or metal-acrylic resin implant-supported dentures with different misfit levels. J Biomech. 2013;46(7):1358\u201362.","journal-title":"J Biomech"},{"issue":"1","key":"575_CR58","doi-asserted-by":"publisher","first-page":"1105","DOI":"10.1007\/s00784-011-0606-z","volume":"16","author":"MT Yucel","year":"2012","unstructured":"Yucel MT, Yondem I, Aykent F, Eraslan O. Influence of the supporting die structures on the fracture strength of all-ceramic materials. Clin Oral Invest. 2012;16(1):1105\u201310.","journal-title":"Clin Oral Invest"},{"key":"575_CR59","doi-asserted-by":"publisher","first-page":"981","DOI":"10.1007\/s00784-017-2178-z","volume":"22","author":"M Obermeier","year":"2018","unstructured":"Obermeier M, Ristow O, Erdelt K, Beuer F. Mechanical performance of cement\u2013and screw\u2013retained all\u2013ceramic single crowns on dental implants. Clin Oral Invest. 2018;22:981\u201391.","journal-title":"Clin Oral Invest"},{"issue":"1","key":"575_CR60","doi-asserted-by":"publisher","first-page":"19","DOI":"10.1016\/S0022-3913(08)60004-9","volume":"99","author":"M Karl","year":"2008","unstructured":"Karl M, Graef F, Wichmann MG, Heckmann SM. The effect of load cycling on metal ceramic screw-retained implant restorations with unrestored and restored screw access holes. J Prosthet Dent. 2008;99(1):19\u201324.","journal-title":"J Prosthet Dent"},{"issue":"5","key":"575_CR61","doi-asserted-by":"publisher","first-page":"323","DOI":"10.3109\/00016359309040583","volume":"51","author":"S Kiliaridis","year":"1993","unstructured":"Kiliaridis S, Kjellberg H, Wenneberg B, Engstr\u00f6m C. The relationship between maximal bite force, bite force endurance, and facial morphology during growth: a cross-sectional study. Acta Odontol Scand. 1993;51(5):323\u201331.","journal-title":"Acta Odontol Scand"},{"issue":"2","key":"575_CR62","doi-asserted-by":"publisher","first-page":"77","DOI":"10.1177\/03946320110240S214","volume":"24","author":"A Scarano","year":"2011","unstructured":"Scarano A, Murmura G, Sinjiari B, Sollazzo V, Spinelli G, Carinci F. Analysis and structural examination of screw loosening in oral implants. Int J Immunopathol Pharmacol. 2011;24(2):77\u201381.","journal-title":"Int J Immunopathol Pharmacol"},{"key":"575_CR63","doi-asserted-by":"crossref","unstructured":"de Vasconcelos JEL, de Matos JDM, Queiroz DA, Lopes G, de Lacerda B, Bottino MA, et al. Implant-abutment misfit after cyclic loading: an in vitro experimental study. Mater (Basel). 2022;15(15):5341.","DOI":"10.3390\/ma15155341"},{"key":"575_CR64","doi-asserted-by":"crossref","unstructured":"Ellakany P, Madi M, Elwan AH, Alshehri T, Aljubran H, Aly NM. Influence of CAD-CAM manufacturing methods on the accuracy and mechanical properties of implant-supported prostheses: a systematic review. J Prosthodont. 2025;34(9):900\u201312.","DOI":"10.1111\/jopr.13933"},{"key":"575_CR65","doi-asserted-by":"publisher","DOI":"10.1016\/j.jdent.2024.105332","volume":"150","author":"P Maldonado","year":"2024","unstructured":"Maldonado P, D\u00f6nmez MB, G\u00fcven ME, Schimmel M, Revilla-Le\u00f3n M, \u00c7akmak G, et al. Digital analysis of fabrication accuracy and fit in additively and subtractively manufactured implant-supported fixed complete dentures. J Dent. 2024;150:105332.","journal-title":"J Dent"},{"key":"575_CR66","doi-asserted-by":"crossref","unstructured":"He Z, Bennani V, Aarts JM, Choi JJE, Veerasamy A. Fit accuracy of 3D printed Co-Cr multiunit implant-supported fixed dental prostheses: a systematic review of in vitro studies. J Prosthet Dent. 2025:S0022-3913(25)00685-7.","DOI":"10.1016\/j.prosdent.2025.08.033"}],"container-title":["Head &amp; Face Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13005-025-00575-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s13005-025-00575-w","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13005-025-00575-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,1,20]],"date-time":"2026-01-20T14:04:18Z","timestamp":1768917858000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s13005-025-00575-w"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,12,13]]},"references-count":66,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["575"],"URL":"https:\/\/doi.org\/10.1186\/s13005-025-00575-w","relation":{},"ISSN":["1746-160X"],"issn-type":[{"value":"1746-160X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,12,13]]},"assertion":[{"value":"18 August 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"24 November 2025","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 December 2025","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The study was approved by the Ethics Committee at Tehran University of Medical Sciences, with the identifier IR.TUMS.DENTISTRY.REC.1401.057.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"6"}}