{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,24]],"date-time":"2026-09-24T00:08:15Z","timestamp":1790208495513,"version":"4.1.0"},"reference-count":38,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2022,9,12]],"date-time":"2022-09-12T00:00:00Z","timestamp":1662940800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,9,12]],"date-time":"2022-09-12T00:00:00Z","timestamp":1662940800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100003725","name":"National Research Foundation of Korea","doi-asserted-by":"publisher","award":["NRF-2021R1F1A1047378"],"award-info":[{"award-number":["NRF-2021R1F1A1047378"]}],"id":[{"id":"10.13039\/501100003725","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Radiat Oncol"],"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>To compare the dosimetric profiles of volumetric modulated arc therapy (VMAT) plans using the fast-rotating O-ring linac (the Halcyon system) based on a dual-layer stacked multi-leaf collimator and helical tomotherapy (HT) for nasopharyngeal cancer (NPCa).\n<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>For 30 NPCa patients, three sets of RT plans were generated, under the same policy of contouring and dose constraints: HT plan; Halcyon VMAT plan with two arcs (HL<jats:sub>2arc<\/jats:sub>); and Halcyon VMAT plan with four arcs (HL<jats:sub>4arc<\/jats:sub>), respectively. The intended dose schedule was to deliver 67.2\u00a0Gy to the planning gross target volume (P-GTV) and 56.0\u00a0Gy to the planning clinical target volume (P-CTV) in 28 fractions using the simultaneously integrated boost concept. Target volumes and organ at risks dose metrics were evaluated for all plans. Normal tissue complication probabilities (NTCP) for esophagus, parotid glands, spinal cord, and brain stem were compared.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>The HT plan achieved the best dose homogeneity index for both P_GTV and P_CTV, followed by the HL<jats:sub>4arc<\/jats:sub> and L<jats:sub>2arc<\/jats:sub> plans. No significant difference in the dose conformity index (CI) for P_GTV was observed between the HT plan (0.80) and either the HL<jats:sub>2arc<\/jats:sub> plan (0.79) or the HL<jats:sub>4arc<\/jats:sub> plan (0.83). The HL<jats:sub>4arc<\/jats:sub> plan showed the best CI for P_CTV (0.88), followed by the HL<jats:sub>2arc<\/jats:sub> plan (0.83) and the HT plan (0.80). The HL<jats:sub>4arc<\/jats:sub> plan (median, interquartile rage (Q1, Q3): 25.36 (22.22, 26.89) Gy) showed the lowest D<jats:sub>mean<\/jats:sub> in the parotid glands, followed by the HT (25.88 (23.87, 27.87) Gy) and HL<jats:sub>2arc<\/jats:sub> plans (28.00 (23.24, 33.99) Gy). In the oral cavity (OC) dose comparison, the HT (22.03 (19.79, 24.85) Gy) plan showed the lowest D<jats:sub>mean<\/jats:sub> compared to the HL<jats:sub>2arc<\/jats:sub> (23.96 (20.84, 28.02) Gy) and HL<jats:sub>4arc<\/jats:sub> (24.14 (20.17, 27.53) Gy) plans. Intermediate and low dose regions (40\u201365% of the prescribed dose) were well fit to the target volume in HL<jats:sub>4arc<\/jats:sub>, compared to the HT and HL<jats:sub>2arc<\/jats:sub> plans. All plans met the dose constraints for the other OARs with sufficient dose margins. The between-group differences in the median NTCP values for the parotid glands and OC were\u2009&lt;\u20093.47% and\u2009&lt;\u20091.7% points, respectively.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusions<\/jats:title>\n                <jats:p>The dosimetric profiles of Halcyon VMAT plans were comparable to that of HT, and HL<jats:sub>4arc<\/jats:sub> showed better dosimetric profiles than HL<jats:sub>2arc<\/jats:sub> for NPCa.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s13014-022-02124-0","type":"journal-article","created":{"date-parts":[[2022,9,12]],"date-time":"2022-09-12T11:04:48Z","timestamp":1662980688000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":9,"title":["Dosimetric comparison between VMAT plans using the fast-rotating O-ring linac with dual-layer stacked MLC and helical tomotherapy for nasopharyngeal carcinoma"],"prefix":"10.1186","volume":"17","author":[{"given":"Sang Gyu","family":"Ju","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yong Chan","family":"Ahn","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yeong-bi","family":"Kim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jin Man","family":"Kim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dong Yeol","family":"Kwon","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Byoung Suk","family":"Park","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kyungmi","family":"Yang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2022,9,12]]},"reference":[{"key":"2124_CR1","doi-asserted-by":"publisher","first-page":"1165","DOI":"10.1016\/j.hoc.2008.08.014","volume":"22","author":"GL Kubicek","year":"2008","unstructured":"Kubicek GL, Machtay M. New advances in high-technology radiotherapy for head and neck cancer. Hematol Oncol Clin N Am. 2008;22:1165.","journal-title":"Hematol Oncol Clin N Am."},{"key":"2124_CR2","doi-asserted-by":"publisher","first-page":"439","DOI":"10.1016\/j.oraloncology.2010.03.005","volume":"46","author":"SA Bhide","year":"2010","unstructured":"Bhide SA, Nutting CM. Advances in radiotherapy for head and neck cancer. Oral Oncol. 2010;46:439\u201341.","journal-title":"Oral Oncol"},{"key":"2124_CR3","doi-asserted-by":"publisher","first-page":"3277","DOI":"10.1200\/JCO.2015.61.2994","volume":"33","author":"V Gregoire","year":"2015","unstructured":"Gregoire V, Langendijk JA, Nuyts S. Advances in radiotherapy for head and neck cancer. J Clin Oncol. 2015;33:3277\u201384.","journal-title":"J Clin Oncol"},{"key":"2124_CR4","doi-asserted-by":"publisher","first-page":"20190209","DOI":"10.1259\/bjr.20190209","volume":"92","author":"XS Sun","year":"2019","unstructured":"Sun XS, Li XY, Chen QY, Tang LQ, Mai HQ. Future of radiotherapy in nasopharyngeal carcinoma. Br J Radiol. 2019;92:20190209.","journal-title":"Br J Radiol"},{"key":"2124_CR5","doi-asserted-by":"publisher","first-page":"97","DOI":"10.1016\/j.oraloncology.2017.08.011","volume":"73","author":"YC Li","year":"2017","unstructured":"Li YC, Chen FP, Zhou GQ, Zhu JH, Hu J, Kang DH, et al. Incidence and dosimetric parameters for brainstem necrosis following intensity modulated radiation therapy in nasopharyngeal carcinoma. Oral Oncol. 2017;73:97\u2013104.","journal-title":"Oral Oncol"},{"key":"2124_CR6","doi-asserted-by":"publisher","first-page":"1007","DOI":"10.1016\/j.ijrobp.2011.09.004","volume":"83","author":"M Little","year":"2012","unstructured":"Little M, Schipper M, Feng FY, Vineberg K, Cornwall C, Murdoch-Kinch CA, et al. Reducing xerostomia after chemo-IMRT for head-and-neck cancer: beyond sparing the parotid glands. Int J Radiat Oncol Biol Phys. 2012;83:1007\u201314.","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"2124_CR7","doi-asserted-by":"publisher","first-page":"S58","DOI":"10.1016\/j.ijrobp.2009.06.090","volume":"76","author":"JO Deasy","year":"2010","unstructured":"Deasy JO, Moiseenko V, Marks L, Chao KSC, Nam J, Eisbruch A. Radiotherapy dose-volume effects on salivary gland function. Int J Radiat Oncol Biol Phys. 2010;76:S58\u201363.","journal-title":"Int J Radiat Oncol Biol Phys."},{"key":"2124_CR8","doi-asserted-by":"publisher","first-page":"695","DOI":"10.1016\/S0360-3016(01)01512-7","volume":"50","author":"A Eisbruch","year":"2001","unstructured":"Eisbruch A, Kim HM, Terrell JE, Marsh LH, Dawson LA, Ship JA. Xerostomia and its predictors following parotid-sparing irradiation of head-and-neck cancer. Int J Radiat Oncol Biol Phys. 2001;50:695\u2013704.","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"2124_CR9","doi-asserted-by":"publisher","first-page":"752","DOI":"10.1016\/j.tranon.2017.06.011","volume":"10","author":"K Li","year":"2017","unstructured":"Li K, Yang L, Hu QY, Chen XZ, Chen M, Chen Y. Oral mucosa dose parameters predicting grade \u2265\u00a03 acute toxicity in locally advanced nasopharyngeal carcinoma patients treated with concurrent intensity-modulated radiation therapy and chemotherapy: an independent validation study comparing oral cavity versus mucosal surface contouring techniques. Transl Oncol. 2017;10:752\u20139.","journal-title":"Transl Oncol"},{"key":"2124_CR10","doi-asserted-by":"publisher","first-page":"259","DOI":"10.1016\/j.radonc.2009.08.015","volume":"93","author":"M Guckenberger","year":"2009","unstructured":"Guckenberger M, Richter A, Krieger T, Wilbert J, Baier K, Flentje M. Is a single arc sufficient in volumetric-modulated arc therapy (VMAT) for complex-shaped target volumes? Radiother Oncol. 2009;93:259\u201365.","journal-title":"Radiother Oncol"},{"key":"2124_CR11","doi-asserted-by":"publisher","first-page":"388","DOI":"10.1016\/j.radonc.2011.08.023","volume":"101","author":"F Stieler","year":"2011","unstructured":"Stieler F, Wolff D, Schmid H, Welzel G, Wenz F, Lohr F. A comparison of several modulated radiotherapy techniques for head and neck cancer and dosimetric validation of VMAT. Radiother Oncol. 2011;101:388\u201393.","journal-title":"Radiother Oncol"},{"key":"2124_CR12","doi-asserted-by":"publisher","first-page":"106","DOI":"10.1002\/acm2.12568","volume":"20","author":"TY Lim","year":"2019","unstructured":"Lim TY, Dragojevic I, Hoffman D, Flores-Martinez E, Kim GY. Characterization of the Halcyon(TM) multileaf collimator system. J Appl Clin Med Phys. 2019;20:106\u201314.","journal-title":"J Appl Clin Med Phys"},{"key":"2124_CR13","doi-asserted-by":"publisher","first-page":"4304","DOI":"10.1002\/mp.13723","volume":"46","author":"T Netherton","year":"2019","unstructured":"Netherton T, Li Y, Gao S, Klopp A, Balter P, Court LE, et al. Experience in commissioning the halcyon linac. Med Phys. 2019;46:4304\u201313.","journal-title":"Med Phys"},{"key":"2124_CR14","first-page":"e3648","volume":"10","author":"T Li","year":"2018","unstructured":"Li T, Scheuermann R, Lin A, Teo BK, Zou W, Swisher-McClure S, et al. Impact of multi-leaf collimator parameters on head and neck plan quality and delivery: a comparison between halcyon and Truebeam(R) treatment delivery systems. Cureus. 2018;10:e3648.","journal-title":"Cureus"},{"key":"2124_CR15","doi-asserted-by":"publisher","first-page":"2949","DOI":"10.1118\/1.2748105","volume":"34","author":"V Sarkar","year":"2007","unstructured":"Sarkar V, Lin L, Shi C, Papanikolaou N. Quality assurance of the multileaf collimator with helical tomotherapy: design and implementation. Med Phys. 2007;34:2949\u201356.","journal-title":"Med Phys"},{"key":"2124_CR16","doi-asserted-by":"publisher","first-page":"4817","DOI":"10.1118\/1.3462971","volume":"37","author":"KM Langen","year":"2010","unstructured":"Langen KM, Papanikolaou N, Balog J, Crilly R, Followill D, Goddu SM, et al. QA for helical tomotherapy: report of the AAPM Task Group 148. Med Phys. 2010;37:4817\u201353.","journal-title":"Med Phys"},{"key":"2124_CR17","doi-asserted-by":"publisher","first-page":"051709","DOI":"10.1118\/1.4870987","volume":"41","author":"Y Rong","year":"2014","unstructured":"Rong Y, Chen Y, Shang L, Zuo L, Lu W, Chen Q. Helical tomotherapy with dynamic running-start-stop delivery compared to conventional tomotherapy delivery. Med Phys. 2014;41:051709.","journal-title":"Med Phys"},{"key":"2124_CR18","doi-asserted-by":"publisher","first-page":"929","DOI":"10.1016\/j.ijrobp.2017.06.2456","volume":"99","author":"JE Bibault","year":"2017","unstructured":"Bibault JE, Dussart S, Pommier P, Morelle M, Huguet M, Boisselier P, et al. Clinical outcomes of several IMRT techniques for patients with head and neck cancer: a propensity score-weighted analysis. Int J Radiat Oncol Biol Phys. 2017;99:929\u201337.","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"2124_CR19","doi-asserted-by":"publisher","first-page":"194","DOI":"10.4103\/0973-1482.65245","volume":"6","author":"V Murthy","year":"2010","unstructured":"Murthy V, Master Z, Gupta T, Ghosh-Laskar S, Budrukkar A, Phurailatpam R, et al. Helical tomotherapy for head and neck squamous cell carcinoma: dosimetric comparison with linear accelerator-based step-and-shoot IMRT. J Cancer Res Ther. 2010;6:194\u20138.","journal-title":"J Cancer Res Ther"},{"key":"2124_CR20","doi-asserted-by":"publisher","first-page":"502","DOI":"10.1007\/s00066-010-2124-3","volume":"186","author":"V Jacob","year":"2010","unstructured":"Jacob V, Bayer W, Astner ST, Busch R, Kneschaurek P. A planning comparison of dynamic IMRT for different collimator leaf thicknesses with helical tomotherapy and RapidArc for prostate and head and neck tumors. Strahlenther Onkol. 2010;186:502\u201310.","journal-title":"Strahlenther Onkol"},{"key":"2124_CR21","doi-asserted-by":"publisher","first-page":"20","DOI":"10.1186\/1748-717X-6-20","volume":"6","author":"T Wiezorek","year":"2011","unstructured":"Wiezorek T, Brachwitz T, Georg D, Blank E, Fotina I, Habl G, et al. Rotational IMRT techniques compared to fixed gantry IMRT and tomotherapy: multi-institutional planning study for head-and-neck cases. Radiat Oncol. 2011;6:20.","journal-title":"Radiat Oncol"},{"key":"2124_CR22","doi-asserted-by":"publisher","first-page":"479","DOI":"10.1016\/j.radonc.2018.04.021","volume":"128","author":"S Michiels","year":"2018","unstructured":"Michiels S, Poels K, Crijns W, Delombaerde L, De Roover R, Vanstraelen B, et al. Volumetric modulated arc therapy of head-and-neck cancer on a fast-rotating O-ring linac: plan quality and delivery time comparison with a C-arm linac. Radiother Oncol. 2018;128:479\u201384.","journal-title":"Radiother Oncol"},{"key":"2124_CR23","doi-asserted-by":"publisher","first-page":"22","DOI":"10.1186\/s13014-020-1473-z","volume":"15","author":"S Panda","year":"2020","unstructured":"Panda S, Swamidas J, Chopra S, Mangaj A, Fogliata A, Kupelian P, et al. Treatment planning comparison of volumetric modulated arc therapy employing a dual-layer stacked multi-leaf collimator and helical tomotherapy for cervix uteri. Radiat Oncol. 2020;15:22.","journal-title":"Radiat Oncol"},{"key":"2124_CR24","doi-asserted-by":"publisher","first-page":"45","DOI":"10.4143\/crt.2020.572","volume":"53","author":"SG Ju","year":"2021","unstructured":"Ju SG, Ahn YC, Kim YB, Park SG, Choi YM, Na CH, et al. Development of a tongue immobilization device using a 3D printer for intensity modulated radiation therapy of nasopharyngeal cancer patients. Cancer Res Treat. 2021;53:45\u201354.","journal-title":"Cancer Res Treat"},{"key":"2124_CR25","doi-asserted-by":"publisher","first-page":"83","DOI":"10.1016\/j.radonc.2015.07.041","volume":"117","author":"CL Brouwer","year":"2015","unstructured":"Brouwer CL, Steenbakkers RJ, Bourhis J, Budach W, Grau C, Gregoire V, et al. CT-based delineation of organs at risk in the head and neck region: DAHANCA, EORTC, GORTEC, HKNPCSG, NCIC CTG, NCRI, NRG Oncology and TROG consensus guidelines. Radiother Oncol. 2015;117:83\u201390.","journal-title":"Radiother Oncol"},{"key":"2124_CR26","doi-asserted-by":"publisher","first-page":"5945","DOI":"10.1118\/1.3644842","volume":"38","author":"M Chen","year":"2011","unstructured":"Chen M, Chen Y, Chen Q, Lu W. Theoretical analysis of the thread effect in helical TomoTherapy. Med Phys. 2011;38:5945\u201360.","journal-title":"Med Phys"},{"key":"2124_CR27","doi-asserted-by":"publisher","first-page":"3013","DOI":"10.1118\/1.3584198","volume":"38","author":"Y Chen","year":"2011","unstructured":"Chen Y, Chen Q, Chen M, Lu W. Dynamic tomotherapy delivery. Med Phys. 2011;38:3013\u201324.","journal-title":"Med Phys"},{"key":"2124_CR28","doi-asserted-by":"publisher","first-page":"79","DOI":"10.1186\/s13014-019-1289-x","volume":"14","author":"CS Hong","year":"2019","unstructured":"Hong CS, Oh D, Ju SG, Ahn YC, Na CH, Kwon DY, et al. Development of a semi-customized tongue displacement device using a 3D printer for head and neck IMRT. Radiat Oncol. 2019;14:79.","journal-title":"Radiat Oncol"},{"issue":"Suppl 3","key":"2124_CR29","doi-asserted-by":"publisher","first-page":"219","DOI":"10.3171\/jns.2000.93.supplement_3.0219","volume":"93","author":"I Paddick","year":"2000","unstructured":"Paddick I. A simple scoring ratio to index the conformity of radiosurgical treatment plans. Technical note. J Neurosurg. 2000;93(Suppl 3):219\u201322.","journal-title":"J Neurosurg"},{"key":"2124_CR30","doi-asserted-by":"publisher","first-page":"947","DOI":"10.1200\/JCO.2006.09.7469","volume":"25","author":"RD Timmerman","year":"2007","unstructured":"Timmerman RD, Kavanagh BD, Cho LC, Papiez L, Xing L. Stereotactic body radiation therapy in multiple organ sites. J Clin Oncol. 2007;25:947\u201352.","journal-title":"J Clin Oncol"},{"key":"2124_CR31","doi-asserted-by":"publisher","first-page":"22","DOI":"10.1186\/1748-717X-4-22","volume":"4","author":"JA Tanyi","year":"2009","unstructured":"Tanyi JA, Summers PA, McCracken CL, Chen Y, Ku LC, Fuss M. Implications of a high-definition multileaf collimator (HD-MLC) on treatment planning techniques for stereotactic body radiation therapy (SBRT): a planning study. Radiat Oncol. 2009;4:22.","journal-title":"Radiat Oncol"},{"key":"2124_CR32","doi-asserted-by":"publisher","first-page":"021712","DOI":"10.1118\/1.4860155","volume":"41","author":"CS Hong","year":"2014","unstructured":"Hong CS, Ju SG, Kim M, Kim JI, Kim JM, Suh TS, et al. Dosimetric effects of multileaf collimator leaf width on intensity-modulated radiotherapy for head and neck cancer. Med Phys. 2014;41:021712.","journal-title":"Med Phys"},{"key":"2124_CR33","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s13014-017-0808-x","volume":"12","author":"A Fogliata","year":"2017","unstructured":"Fogliata A, Reggiori G, Stravato A, Lobefalo F, Franzese C, Franceschini D, et al. RapidPlan head and neck model: the objectives and possible clinical benefit. Radiat Oncol. 2017;12:1\u201312.","journal-title":"Radiat Oncol."},{"key":"2124_CR34","doi-asserted-by":"publisher","first-page":"249","DOI":"10.1080\/09553009214552071","volume":"62","author":"P Kallman","year":"1992","unstructured":"Kallman P, Agren A, Brahme A. Tumour and normal tissue responses to fractionated non-uniform dose delivery. Int J Radiat Biol. 1992;62:249\u201362.","journal-title":"Int J Radiat Biol"},{"key":"2124_CR35","doi-asserted-by":"publisher","first-page":"20190270","DOI":"10.1259\/bjr.20190270","volume":"92","author":"S Chiavassa","year":"2019","unstructured":"Chiavassa S, Bessieres I, Edouard M, Mathot M, Moignier A. Complexity metrics for IMRT and VMAT plans: a review of current literature and applications. Br J Radiol. 2019;92:20190270.","journal-title":"Br J Radiol"},{"key":"2124_CR36","doi-asserted-by":"publisher","first-page":"1356","DOI":"10.1016\/j.ijrobp.2009.10.002","volume":"78","author":"DL Schwartz","year":"2010","unstructured":"Schwartz DL, Hutcheson K, Barringer D, Tucker SL, Kies M, Holsinger FC, et al. Candidate dosimetric predictors of long-term swallowing dysfunction after oropharyngeal intensity-modulated radiotherapy. Int J Radiat Oncol Biol Phys. 2010;78:1356\u201365.","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"2124_CR37","doi-asserted-by":"publisher","first-page":"52","DOI":"10.1016\/j.ijrobp.2009.10.057","volume":"79","author":"G Sanguineti","year":"2011","unstructured":"Sanguineti G, Gunn GB, Parker BC, Endres EJ, Zeng J, Fiorino C. Weekly dose-volume parameters of mucosa and constrictor muscles predict the use of percutaneous endoscopic gastrostomy during exclusive intensity-modulated radiotherapy for oropharyngeal cancer. Int J Radiat Oncol Biol Phys. 2011;79:52\u20139.","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"2124_CR38","doi-asserted-by":"publisher","first-page":"E815","DOI":"10.1002\/hed.24106","volume":"38","author":"R Mazzola","year":"2016","unstructured":"Mazzola R, Ricchetti F, Fersino S, Fiorentino A, Giaj Levra N, Di Paola G, et al. Predictors of mucositis in oropharyngeal and oral cavity cancer in patients treated with volumetric modulated radiation treatment: a dose-volume analysis. Head Neck. 2016;38:E815\u20139.","journal-title":"Head Neck"}],"container-title":["Radiation Oncology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13014-022-02124-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s13014-022-02124-0\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13014-022-02124-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,10,5]],"date-time":"2022-10-05T13:19:19Z","timestamp":1664975959000},"score":1,"resource":{"primary":{"URL":"https:\/\/ro-journal.biomedcentral.com\/articles\/10.1186\/s13014-022-02124-0"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,9,12]]},"references-count":38,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2022,12]]}},"alternative-id":["2124"],"URL":"https:\/\/doi.org\/10.1186\/s13014-022-02124-0","relation":{},"ISSN":["1748-717X"],"issn-type":[{"value":"1748-717X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,9,12]]},"assertion":[{"value":"29 March 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"30 August 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"12 September 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The institutional review board at Samsung Medical Center (file no. SMC 2020-08-120-001, August 28, 2021).","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"Conflict of interest relevant to this article was not reported.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"155"}}