{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,30]],"date-time":"2026-09-30T19:52:15Z","timestamp":1790797935324,"version":"4.1.0"},"reference-count":35,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2023,1,5]],"date-time":"2023-01-05T00:00:00Z","timestamp":1672876800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2023,1,5]],"date-time":"2023-01-05T00:00:00Z","timestamp":1672876800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Radiat Oncol"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Objective<\/jats:title>\n                    <jats:p>Anatomical variations existing in cervical cancer radiotherapy treatment can be monitored by cone-beam computed tomography (CBCT) images. Deformable image registration (DIR) from planning CT (pCT) to CBCT images and synthetic CT (sCT) image generation based on CBCT are two methods for improving the quality of CBCT images. This study aims to compare the accuracy of these two approaches geometrically and dosimetrically in cervical cancer radiotherapy.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>\n                      In this study, 40 paired pCT-CBCT images were collected to evaluate the accuracy of DIR and sCT generation. The DIR method was based on a 3D multistage registration network that was trained with 150 paired pCT-CBCT images, and the sCT generation method was performed based on a 2D cycle-consistent adversarial network (CycleGAN) with 6000 paired pCT-CBCT slices for training. Then, the doses were recalculated with the CBCT, pCT, deformed pCT (dpCT) and sCT images by a GPU-based Monte Carlo dose code, ArcherQA, to obtain Dose\n                      <jats:sub>CBCT<\/jats:sub>\n                      , Dose\n                      <jats:sub>pCT<\/jats:sub>\n                      , Dose\n                      <jats:sub>dpCT<\/jats:sub>\n                      and Dose\n                      <jats:sub>sCT<\/jats:sub>\n                      . Organs at risk (OARs) included small intestine, rectum, bladder, spinal cord, femoral heads and bone marrow, CBCT and pCT contours were delineated manually, dpCT contours were propagated through deformation vector fields, sCT contours were auto-segmented and corrected manually.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      The global gamma pass rate of Dose\n                      <jats:sub>sCT<\/jats:sub>\n                      and Dose\n                      <jats:sub>dpCT<\/jats:sub>\n                      was 99.66%\u2009\u00b1\u20090.34%, while that of Dose\n                      <jats:sub>CBCT<\/jats:sub>\n                      and Dose\n                      <jats:sub>dpCT<\/jats:sub>\n                      was 85.92%\u2009\u00b1\u20097.56% at the 1%\/1\u00a0mm criterion and a low-dose threshold of 10%. Based on Dose\n                      <jats:sub>dpCT<\/jats:sub>\n                      as uniform dose distribution, there were comparable errors in femoral heads and bone marrow for the dpCT and sCT contours compared with CBCT contours, while sCT contours had lower errors in small intestine, rectum, bladder and spinal cord, especially for those with large volume difference of pCT and CBCT.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>For cervical cancer radiotherapy, the DIR method and sCT generation could produce similar precise dose distributions, but sCT contours had higher accuracy when the difference in planning CT and CBCT was large.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s13014-022-02191-3","type":"journal-article","created":{"date-parts":[[2023,1,5]],"date-time":"2023-01-05T10:03:57Z","timestamp":1672913037000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":16,"title":["Dosimetric comparison of deformable image registration and synthetic CT generation based on CBCT images for organs at risk in cervical cancer radiotherapy"],"prefix":"10.1186","volume":"18","author":[{"given":"Yankui","family":"Chang","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yongguang","family":"Liang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bo","family":"Yang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jie","family":"Qiu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xi","family":"Pei","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xie George","family":"Xu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2023,1,5]]},"reference":[{"issue":"2","key":"2191_CR1","doi-asserted-by":"publisher","first-page":"590","DOI":"10.1016\/j.ijrobp.2007.08.067","volume":"70","author":"JJ Sonke","year":"2008","unstructured":"Sonke JJ, Lebesque J, van Herk M. Variability of four-dimensional computed tomography patient models. Int J Radiat Oncol Biol Phys. 2008;70(2):590\u20138.","journal-title":"Int J Radiat Oncol Biol Phys"},{"issue":"3","key":"2191_CR2","doi-asserted-by":"publisher","first-page":"392","DOI":"10.1016\/j.radonc.2014.10.009","volume":"113","author":"M Kwint","year":"2014","unstructured":"Kwint M, et al. Intra thoracic anatomical changes in lung cancer patients during the course of radiotherapy. Radiother Oncol. 2014;113(3):392\u20137.","journal-title":"Radiother Oncol"},{"issue":"6","key":"2191_CR3","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/aab0f0","volume":"63","author":"TE Marchant","year":"2018","unstructured":"Marchant TE, Joshi KD, Moore CJ. Accuracy of radiotherapy dose calculations based on cone-beam CT: comparison of deformable registration and image correction based methods. Phys Med Biol. 2018;63(6): 065003.","journal-title":"Phys Med Biol"},{"key":"2191_CR4","doi-asserted-by":"publisher","first-page":"361","DOI":"10.4236\/ijmpcero.2017.64032","volume":"6","author":"T Abe","year":"2017","unstructured":"Abe T, et al. Method for converting cone-beam CT values into Hounsfield units for radiation treatment planning. Int J Med Phys, Clin Eng Rad Oncol. 2017;6:361\u201375.","journal-title":"Int J Med Phys, Clin Eng Rad Oncol."},{"key":"2191_CR5","doi-asserted-by":"crossref","unstructured":"Marchant TE, Joshi KD and Moore CJ. Shading correction for cone-beam CT in radiotherapy: validation of dose calculation accuracy using clinical images. In Proc. SPIE 10132, Medical Imaging 2017: Physics of Medical Imaging. 2017:10132;101320J1\u2013101320J11.","DOI":"10.1117\/12.2254059"},{"key":"2191_CR6","doi-asserted-by":"publisher","first-page":"25","DOI":"10.1007\/s13566-020-00417-z","volume":"9","author":"S Pramanik","year":"2020","unstructured":"Pramanik S, et al. Analysis of setup uncertainties and determine the variation of the clinical target volume (CTV) to planning target volume (PTV) margin for various tumor sites treated with three-dimensional IGRT couch using KV-CBCT. J Radiat Oncol. 2020;9:25\u201335.","journal-title":"J Radiat Oncol"},{"issue":"20","key":"2191_CR7","doi-asserted-by":"publisher","first-page":"3683","DOI":"10.7150\/jca.27220","volume":"9","author":"Z Liu","year":"2018","unstructured":"Liu Z, Liu X, Zhang F, et al. How much margin do we need for pelvic lymph nodes irradiation in the era of IGRT? Cancer. 2018;9(20):3683\u20139.","journal-title":"Cancer"},{"issue":"5","key":"2191_CR8","doi-asserted-by":"publisher","first-page":"1899","DOI":"10.1002\/mp.12850","volume":"45","author":"A Maslowski","year":"2018","unstructured":"Maslowski A, Wang A, Sun M, et al. Acuros CTS: A fast, linear Boltzmann transport equation solver for computed tomography scatter - Part I: Core algorithms and validation. Med Phys. 2018;45(5):1899\u2013913.","journal-title":"Med Phys"},{"issue":"5","key":"2191_CR9","doi-asserted-by":"publisher","first-page":"1914","DOI":"10.1002\/mp.12849","volume":"45","author":"A Wang","year":"2018","unstructured":"Wang A, et al. Acuros CTS: A fast, linear Boltzmann transport equation solver for computed tomography scatter: Part II: System modeling, scatter correction, and optimization. Med Phys. 2018;45(5):1914\u201325.","journal-title":"Med Phys"},{"key":"2191_CR10","doi-asserted-by":"publisher","first-page":"112","DOI":"10.1016\/j.ejmp.2019.11.015","volume":"68","author":"T Jarema","year":"2019","unstructured":"Jarema T, Aland T. Using the iterative kV CBCT reconstruction on the Varian Halcyon linear accelerator for radiation therapy planning for pelvis patients. Phys Med. 2019;68:112\u20136.","journal-title":"Phys Med"},{"key":"2191_CR11","doi-asserted-by":"crossref","unstructured":"Lazos, D, Pokhrel, D, Zhong, S, et al. Experimental validation of a Monte Carlo-based kV x-ray projection model for the Varian linac-mounted Cone-Beam CT imaging system. In Medical Imaging 2008 - Physics of Medical Imaging. 2008. 6913","DOI":"10.1117\/12.772873"},{"key":"2191_CR12","doi-asserted-by":"publisher","first-page":"105487","DOI":"10.1016\/j.cmpb.2020.105487","volume":"194","author":"Y Zhang","year":"2020","unstructured":"Zhang Y, et al. Scatter correction based on adaptive photon path-based Monte Carlo simulation method in multi-GPU platform. Comput Methods Programs Biomed. 2020;194:105487.","journal-title":"Comput Methods Programs Biomed"},{"issue":"3","key":"2191_CR13","doi-asserted-by":"publisher","first-page":"42","DOI":"10.1186\/1748-717X-3-42","volume":"16","author":"A Richter","year":"2008","unstructured":"Richter A, et al. Investigation of the usability of conebeam CT data sets for dose calculation. Radiat Oncol. 2008;16(3):42.","journal-title":"Radiat Oncol"},{"issue":"2","key":"2191_CR14","doi-asserted-by":"publisher","first-page":"249","DOI":"10.1016\/j.radonc.2012.06.007","volume":"104","author":"I Fotina","year":"2012","unstructured":"Fotina I, Hopfgartner J, Stock M, et al. Feasibility of CBCT-based dose calculation: comparative analysis of HU adjustment techniques. Radiother Oncol. 2012;104(2):249\u201356.","journal-title":"Radiother Oncol"},{"issue":"5","key":"2191_CR15","doi-asserted-by":"publisher","first-page":"1553","DOI":"10.1016\/j.ijrobp.2006.08.031","volume":"66","author":"S Yoo","year":"2006","unstructured":"Yoo S, Yin FF. Dosimetric feasibility of cone-beam CT-based treatment planning compared to CT-based treatment planning. Int J Radiat Oncol. 2006;66(5):1553\u201361.","journal-title":"Int J Radiat Oncol"},{"issue":"2","key":"2191_CR16","doi-asserted-by":"publisher","first-page":"175","DOI":"10.1007\/s00066-018-1379-y","volume":"195","author":"A Barateau","year":"2019","unstructured":"Barateau A, et al. A density assignment method for dose monitoring in head-and-neck radiotherapy. Strahlenther Onkol. 2019;195(2):175\u201385.","journal-title":"Strahlenther Onkol"},{"issue":"1096","key":"2191_CR17","doi-asserted-by":"publisher","first-page":"20180383","DOI":"10.1259\/bjr.20180383","volume":"92","author":"V Giacometti","year":"2019","unstructured":"Giacometti V, et al. An evaluation of techniques for dose calculation on cone beam computed tomography. Br J Radiol. 2019;92(1096):20180383.","journal-title":"Br J Radiol"},{"issue":"14","key":"2191_CR18","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/ab2770","volume":"64","author":"Y Li","year":"2019","unstructured":"Li Y, et al. A preliminary study of using a deep convolution neural network to generate synthesized CT images based on CBCT for adaptive radiotherapy of nasopharyngeal carcinoma. Phys Med Biol. 2019;64(14): 145010.","journal-title":"Phys Med Biol"},{"issue":"5","key":"2191_CR19","doi-asserted-by":"publisher","first-page":"265","DOI":"10.1259\/dmfr\/30642039","volume":"40","author":"R Schulze","year":"2011","unstructured":"Schulze R, et al. Artefacts in CBCT: a review. Dentomaxillofac Radiol. 2011;40(5):265\u201373.","journal-title":"Dentomaxillofac Radiol"},{"key":"2191_CR20","doi-asserted-by":"publisher","first-page":"31703","DOI":"10.1118\/1.4864240","volume":"41","author":"C Veiga","year":"2014","unstructured":"Veiga C, McClelland J, Moinuddin S, et al. Toward adaptive radiotherapy for head and neck patients: feasibility study on using CT-to-CBCT deformable registration for \u2018dose of the day\u2019 calculations. Med Phys. 2014;41:31703.","journal-title":"Med Phys"},{"issue":"20","key":"2191_CR21","doi-asserted-by":"publisher","first-page":"20TR01","DOI":"10.1088\/1361-6560\/ab843e","volume":"65","author":"Y Fu","year":"2020","unstructured":"Fu Y, Lei Y, Wang T, et al. Deep learning in medical image registration: a review. Phys Med Biol. 2020;65(20):20TR01.","journal-title":"Phys Med Biol"},{"key":"2191_CR22","doi-asserted-by":"publisher","first-page":"11","DOI":"10.1088\/1361-6560\/ac01b6","volume":"66","author":"L Chen","year":"2021","unstructured":"Chen L, Liang X, Shen C, et al. Synthetic CT generation from CBCT images via unsupervised deep learning. Phys Med Biol. 2021;66:11.","journal-title":"Phys Med Biol"},{"key":"2191_CR23","doi-asserted-by":"crossref","unstructured":"Deng L, Zhang M, Wang J, et al. Improving cone-beam CT quality using a cycle-residual connection with a dilated convolution-consistent generative adversarial network. Phys Med Biol. 2022.","DOI":"10.1088\/1361-6560\/ac7b0a"},{"issue":"9","key":"2191_CR24","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/ab7d54","volume":"65","author":"A Thummerer","year":"2020","unstructured":"Thummerer A, et al. Comparison of CBCT based synthetic CT methods suitable for proton dose calculations in adaptive proton therapy. Phys Med Biol. 2020;65(9): 095002.","journal-title":"Phys Med Biol"},{"issue":"23","key":"2191_CR25","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/abb1d6","volume":"65","author":"A Thummerer","year":"2020","unstructured":"Thummerer A, et al. Comparison of the suitability of CBCT- and MR-based synthetic CTs for daily adaptive proton therapy in head and neck patients. Phys Med Biol. 2020;65(23): 235036.","journal-title":"Phys Med Biol"},{"issue":"10","key":"2191_CR26","doi-asserted-by":"publisher","first-page":"4683","DOI":"10.1002\/mp.14387","volume":"47","author":"A Barateau","year":"2020","unstructured":"Barateau A, et al. Comparison of CBCT-based dose calculation methods in head and neck cancer radiotherapy: from Hounsfield unit to density calibration curve to deep learning. Med Phys. 2020;47(10):4683\u201393.","journal-title":"Med Phys"},{"key":"2191_CR27","doi-asserted-by":"publisher","first-page":"896795","DOI":"10.3389\/fonc.2022.896795","volume":"12","author":"B Yang","year":"2022","unstructured":"Yang B, et al. A Comparison Study Between CNNBased Deformed Planning CT and CycleGAN-Based Synthetic CT Methods for Improving iCBCT Image Quality. Front Oncol. 2022;12:896795.","journal-title":"Front Oncol"},{"key":"2191_CR28","first-page":"770","volume":"2016","author":"K He","year":"2016","unstructured":"He K, Zhang X, Ren S, et al. Deep residual learning for image recognition. IEEE conference on computer vision and pattern recognition (CVPR). 2016;2016:770\u20138.","journal-title":"IEEE conference on computer vision and pattern recognition (CVPR)."},{"key":"2191_CR29","doi-asserted-by":"publisher","first-page":"13","DOI":"10.3389\/fninf.2014.00013","volume":"8","author":"M McCormick","year":"2014","unstructured":"McCormick M, Liu X, Jomier J, et al. ITK: enabling reproducible research and open science. Front Neuroinform. 2014;8:13.","journal-title":"Front Neuroinform"},{"key":"2191_CR30","unstructured":"Yoo TS at al. Engineering and Algorithm Design for an Image Processing API: A Technical Report on ITK \u2013 The Insight Toolkit. In Proc. of Medicine Meets Virtual Reality, J. Westwood, ed., IOS Press Amsterdam. 2002. 586\u2013592"},{"issue":"7","key":"2191_CR31","doi-asserted-by":"publisher","DOI":"10.1118\/1.4884229","volume":"41","author":"L Su","year":"2014","unstructured":"Su L, et al. ARCHERRT\u2014a photon-electron coupled Monte Carlo dose computing engine for GPU: software development and application to helical tomotherapy. Med Phys. 2014;41(7): 071709.","journal-title":"Med Phys"},{"issue":"6","key":"2191_CR32","doi-asserted-by":"publisher","first-page":"17","DOI":"10.1088\/1361-6560\/ac58dd","volume":"67","author":"Z Peng","year":"2022","unstructured":"Peng Z, et al. Development of a GPU-accelerated Monte Carlo dose calculation module for nuclear medicine, ARCHER-NM: demonstration for a PET\/CT imaging procedure. Phys Med Biol. 2022;67(6):17.","journal-title":"Phys Med Biol"},{"issue":"10","key":"2191_CR33","doi-asserted-by":"publisher","first-page":"82","DOI":"10.1002\/acm2.13399","volume":"22","author":"M Moazzezi","year":"2011","unstructured":"Moazzezi M, Rose B, Kisling K, et al. Prospects for daily online adaptive radiotherapy via ethos for prostate cancer patients without nodal involvement using unedited CBCT auto-segmentation. J Appl Clin Med Phys. 2011;22(10):82\u201393.","journal-title":"J Appl Clin Med Phys"},{"issue":"2","key":"2191_CR34","first-page":"77","volume":"8","author":"Y Archambault","year":"2020","unstructured":"Archambault Y, et al. Making on-line adaptive radiotherapy possible using artificial intelligence and machine learning for efficient daily re-planning. Med Phys Intl J. 2020;8(2):77\u201386.","journal-title":"Med Phys Intl J"},{"issue":"6","key":"2191_CR35","doi-asserted-by":"publisher","first-page":"2472","DOI":"10.1002\/mp.14121","volume":"47","author":"Y Liu","year":"2020","unstructured":"Liu Y, et al. CBCT-based synthetic CT generation using deep-attention cycleGAN for pancreatic adaptive radiotherapy. Med Phys. 2020;47(6):2472\u201383.","journal-title":"Med Phys"}],"container-title":["Radiation Oncology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13014-022-02191-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s13014-022-02191-3\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13014-022-02191-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,1,5]],"date-time":"2023-01-05T10:07:15Z","timestamp":1672913235000},"score":1,"resource":{"primary":{"URL":"https:\/\/ro-journal.biomedcentral.com\/articles\/10.1186\/s13014-022-02191-3"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,1,5]]},"references-count":35,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2023,12]]}},"alternative-id":["2191"],"URL":"https:\/\/doi.org\/10.1186\/s13014-022-02191-3","relation":{"has-preprint":[{"id-type":"doi","id":"10.21203\/rs.3.rs-2150448\/v1","asserted-by":"object"}]},"ISSN":["1748-717X"],"issn-type":[{"value":"1748-717X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,1,5]]},"assertion":[{"value":"10 October 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"27 December 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"5 January 2023","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The studies involving human participants were reviewed and approved by Medical Ethics Committee of Peking Union Medical College Hospital. The patients\/participants provided their written informed consent to participate in this study.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"Author XP is employed by Anhui Wisdom Technology Co., Ltd. The remaining authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"3"}}