{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,27]],"date-time":"2026-05-27T12:55:58Z","timestamp":1779886558356,"version":"3.53.1"},"reference-count":25,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2023,7,1]],"date-time":"2023-07-01T00:00:00Z","timestamp":1688169600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2023,7,1]],"date-time":"2023-07-01T00:00:00Z","timestamp":1688169600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"crossref","award":["12005302"],"award-info":[{"award-number":["12005302"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"crossref"}]},{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"crossref","award":["11975313"],"award-info":[{"award-number":["11975313"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Radiat Oncol"],"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Purpose<\/jats:title>\n                <jats:p>This study was to improve image quality for high-speed MR imaging using a deep learning method for online adaptive radiotherapy in prostate cancer. We then evaluated its benefits on image registration.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>Sixty pairs of 1.5\u00a0T MR images acquired with an MR-linac were enrolled. The data included low-speed, high-quality (LSHQ), and high-speed low-quality (HSLQ) MR images. We proposed a CycleGAN, which is based on the data augmentation technique, to learn the mapping between the HSLQ and LSHQ images and then generate synthetic LSHQ (synLSHQ) images from the HSLQ images. Five-fold cross-validation was employed to test the CycleGAN model. The normalized mean absolute error (nMAE), peak signal-to-noise ratio (PSNR), structural similarity index measurement (SSIM), and edge keeping index (EKI) were calculated to determine image quality. The Jacobian determinant value (JDV), Dice similarity coefficient (DSC), and mean distance to agreement (MDA) were used to analyze deformable registration.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>Compared with the LSHQ, the proposed synLSHQ achieved comparable image quality and reduced imaging time by\u2009~\u200966%. Compared with the HSLQ, the synLSHQ had better image quality with improvement of 57%, 3.4%, 26.9%, and 3.6% for nMAE, SSIM, PSNR, and EKI, respectively. Furthermore, the synLSHQ enhanced registration accuracy with a superior mean JDV (6%) and preferable DSC and MDA values compared with HSLQ.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusion<\/jats:title>\n                <jats:p>The proposed method can generate high-quality images from high-speed scanning sequences. As a result, it shows potential to shorten the scan time while ensuring the accuracy of radiotherapy.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s13014-023-02306-4","type":"journal-article","created":{"date-parts":[[2023,7,1]],"date-time":"2023-07-01T10:02:01Z","timestamp":1688205721000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":9,"title":["Improving accelerated 3D imaging in MRI-guided radiotherapy for prostate cancer using a deep learning method"],"prefix":"10.1186","volume":"18","author":[{"given":"Ji","family":"Zhu","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xinyuan","family":"Chen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yuxiang","family":"Liu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bining","family":"Yang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ran","family":"Wei","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shirui","family":"Qin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zhuanbo","family":"Yang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zhihui","family":"Hu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jianrong","family":"Dai","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kuo","family":"Men","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2023,7,1]]},"reference":[{"key":"2306_CR1","doi-asserted-by":"publisher","first-page":"041t1","DOI":"10.1088\/1361-6560\/abd66d","volume":"66","author":"C Kontaxis","year":"2021","unstructured":"Kontaxis C, Woodhead PL, Bol GH, Lagendijk JJW, Raaymakers BW. Proof-of-concept delivery of intensity modulated arc therapy on the Elekta Unity 1.5 T MR-linac. Phys Med Biol. 2021;66:041t1.","journal-title":"Phys Med Biol"},{"key":"2306_CR2","doi-asserted-by":"publisher","first-page":"3","DOI":"10.1016\/j.semradonc.2014.02.009","volume":"24","author":"JJ Lagendijk","year":"2014","unstructured":"Lagendijk JJ, Raaymakers BW, van Vulpen M. The magnetic resonance imaging-linac system. Seminar Radiat Oncol. 2014;24:3.","journal-title":"Seminar Radiat Oncol"},{"key":"2306_CR3","doi-asserted-by":"publisher","first-page":"L41","DOI":"10.1088\/1361-6560\/aa9517","volume":"62","author":"BW Raaymakers","year":"2017","unstructured":"Raaymakers BW, J\u00fcrgenliemk-Schulz IM, Bol GH, Glitzner M, Kotte ANTJ, Van Asselen B, et al. First patients treated with a 1.5 T MRI-Linac: clinical proof of concept of a high-precision, high-field MRI guided radiotherapy treatment. Phys Med Biol. 2017;62:L41\u201350.","journal-title":"Phys Med Biol"},{"key":"2306_CR4","doi-asserted-by":"publisher","first-page":"54","DOI":"10.1016\/j.ctro.2019.04.001","volume":"18","author":"D Winkel","year":"2019","unstructured":"Winkel D, Bol GH, Kroon PS, van Asselen B, Hackett SS, Werensteijn-Honingh AM, et al. Adaptive radiotherapy: the Elekta Unity MR-linac concept. Clin Transl Radiat Oncol. 2019;18:54\u20139.","journal-title":"Clin Transl Radiat Oncol"},{"key":"2306_CR5","doi-asserted-by":"publisher","DOI":"10.1088\/1361-6560\/aafd6b","volume":"64","author":"T Bruijnen","year":"2019","unstructured":"Bruijnen T, Stemkens B, Lagendijk JJW, van den Berg CAT, Tijssen RHN. Multiresolution radial MRI to reduce IDLE time in pre-beam imaging on an MR-Linac (MR-RIDDLE). Phys Med Biol. 2019;64: 055011.","journal-title":"Phys Med Biol"},{"key":"2306_CR6","doi-asserted-by":"crossref","unstructured":"Zhang Y, Cheng JZ, Xiang L, Yap PT, Shen D. Dual-Domain Cascaded Regression for Synthesizing 7T from 3T MRI. In: Medical image computing and computer-assisted intervention: MICCAI International Conference on Medical Image Computing and Computer-Assisted Intervention. 2018. vol. 11070, p. 410\u20137","DOI":"10.1007\/978-3-030-00928-1_47"},{"key":"2306_CR7","doi-asserted-by":"publisher","first-page":"1182","DOI":"10.1002\/mrm.21391","volume":"58","author":"M Lustig","year":"2007","unstructured":"Lustig M, Donoho D, Pauly JM. Sparse MRI: the application of compressed sensing for rapid MR imaging. Magn Reson Med. 2007;58:1182\u201395.","journal-title":"Magn Reson Med"},{"key":"2306_CR8","doi-asserted-by":"publisher","first-page":"167","DOI":"10.1109\/TMI.2018.2858752","volume":"38","author":"M Mardani","year":"2019","unstructured":"Mardani M, Gong E, Cheng JY, Vasanawala SS, Zaharchuk G, Xing L, et al. Deep generative adversarial neural networks for compressive sensing MRI. IEEE Trans Med Imaging. 2019;38:167\u201379.","journal-title":"IEEE Trans Med Imaging"},{"key":"2306_CR9","doi-asserted-by":"crossref","unstructured":"Alexander DC, Zikic D, Zhang J, Zhang H, Criminisi A. Image quality transfer via random forest regression: applications in diffusion MRI. In: Medical image computing and computer-assisted intervention: MICCAI International Conference on Medical Image Computing and Computer-Assisted Intervention. 2014. vol. 17, p. 225\u201332.","DOI":"10.1007\/978-3-319-10443-0_29"},{"key":"2306_CR10","doi-asserted-by":"publisher","first-page":"803","DOI":"10.1109\/TMI.2017.2764326","volume":"37","author":"A Chartsias","year":"2018","unstructured":"Chartsias A, Joyce T, Giuffrida MV, Tsaftaris SA. Multimodal MR synthesis via modality-invariant latent representation. IEEE Trans Med Imaging. 2018;37:803\u201314.","journal-title":"IEEE Trans Med Imaging"},{"key":"2306_CR11","doi-asserted-by":"publisher","first-page":"93","DOI":"10.1016\/j.mri.2019.03.012","volume":"66","author":"Y Wu","year":"2020","unstructured":"Wu Y, Ma Y, Capaldi DP, Liu J, Zhao W, Du J, et al. Incorporating prior knowledge via volumetric deep residual network to optimize the reconstruction of sparsely sampled MRI. Magn Reson Imaging. 2020;66:93\u2013103.","journal-title":"Magn Reson Imaging"},{"key":"2306_CR12","doi-asserted-by":"publisher","first-page":"3120","DOI":"10.1002\/mp.12945","volume":"45","author":"KH Kim","year":"2018","unstructured":"Kim KH, Do WJ, Park SH. Improving resolution of MR images with an adversarial network incorporating images with different contrast. Med Phys. 2018;45:3120.","journal-title":"Med Phys"},{"key":"2306_CR13","doi-asserted-by":"publisher","first-page":"1488","DOI":"10.1109\/TMI.2018.2820120","volume":"37","author":"TM Quan","year":"2018","unstructured":"Quan TM, Nguyen-Duc T, Jeong WK. Compressed sensing MRI reconstruction using a generative adversarial network with a cyclic loss. IEEE Trans Med Imaging. 2018;37:1488\u201397.","journal-title":"IEEE Trans Med Imaging"},{"key":"2306_CR14","doi-asserted-by":"publisher","first-page":"174","DOI":"10.1002\/mrm.27707","volume":"82","author":"F Liu","year":"2019","unstructured":"Liu F, Feng L, Kijowski R. MANTIS: model-augmented neural neTwork with incoherent k-space sampling for efficient MR parameter mapping. Magn Reson Med. 2019;82:174\u201388.","journal-title":"Magn Reson Med"},{"key":"2306_CR15","doi-asserted-by":"crossref","unstructured":"Zhu JY, Park T, Isola P, Efros AA. Unpaired image-to-image translation using cycle-consistent adversarial networks. In: IEEE. 2017.","DOI":"10.1109\/ICCV.2017.244"},{"key":"2306_CR16","doi-asserted-by":"crossref","unstructured":"Isola P, Zhu J, Zhou T, Efros AA. Image-to-image translation with conditional adversarial networks. In: 2017 IEEE Conference on Computer Vision and Pattern Recognition (CVPR), p. 5967\u201376.","DOI":"10.1109\/CVPR.2017.632"},{"key":"2306_CR17","doi-asserted-by":"crossref","unstructured":"Rao RB, Fung G. On the dangers of cross-validation. An experimental evaluation. In: Proceedings of the SIAM International Conference on Data Mining, SDM 2008, April 24\u201326, 2008. Atlanta","DOI":"10.1137\/1.9781611972788.54"},{"key":"2306_CR18","first-page":"012049","volume":"324","author":"W Wang","year":"2018","unstructured":"Wang W, Lu Y. Analysis of the mean absolute error (MAE) and the root mean square error (RMSE) in assessing rounding model. Iop Conf. 2018;324:012049.","journal-title":"Iop Conf"},{"key":"2306_CR19","doi-asserted-by":"publisher","first-page":"357","DOI":"10.1002\/mp.15380","volume":"49","author":"H Xie","year":"2021","unstructured":"Xie H, Lei Y, Wang T, Roper J, Dhabaan AH, Bradley JD, et al. Synthesizing high-resolution magnetic resonance imaging using parallel cycle-consistent generative adversarial networks for fast magnetic resonance imaging. Med Phys. 2021;49:357.","journal-title":"Med Phys"},{"key":"2306_CR20","doi-asserted-by":"publisher","first-page":"600","DOI":"10.1109\/TIP.2003.819861","volume":"13","author":"Z Wang","year":"2004","unstructured":"Wang Z, Bovik AC, Sheikh HR, Simoncelli EP. Image quality assessment: from error visibility to structural similarity. IEEE Trans Image Process Publ IEEE Signal Process Soc. 2004;13:600\u201312.","journal-title":"IEEE Trans Image Process Publ IEEE Signal Process Soc"},{"key":"2306_CR21","doi-asserted-by":"publisher","first-page":"11","DOI":"10.1002\/acm2.13121","volume":"22","author":"T Wang","year":"2021","unstructured":"Wang T, Lei Y, Fu Y, Wynne JF, Curran WJ, Liu T, et al. A review on medical imaging synthesis using deep learning and its clinical applications. J Appl Clin Med Phys. 2021;22:11\u201336.","journal-title":"J Appl Clin Med Phys"},{"key":"2306_CR22","doi-asserted-by":"publisher","first-page":"220","DOI":"10.1504\/IJSISE.2011.044537","volume":"4","author":"HS Bhadauria","year":"2011","unstructured":"Bhadauria HS, Dewal ML. Image denoising based on adaptive fusion of curvelet transform and total variation. Int J Signal Imaging Syst Eng. 2011;4:220.","journal-title":"Int J Signal Imaging Syst Eng"},{"key":"2306_CR23","doi-asserted-by":"publisher","first-page":"e43","DOI":"10.1002\/mp.12256","volume":"44","author":"KK Brock","year":"2017","unstructured":"Brock KK, Mutic S, Mcnutt TR, Hua L, Kessler ML. Use of image registration and fusion algorithms and techniques in radiotherapy: report of the AAPM radiation therapy committee task group No. 132. Med Phys. 2017;44:e43.","journal-title":"Med Phys"},{"key":"2306_CR24","doi-asserted-by":"publisher","first-page":"1094","DOI":"10.1002\/mp.13976","volume":"47","author":"EM McKenzie","year":"2020","unstructured":"McKenzie EM, Santhanam A, Ruan D, O\u2019Connor D, Cao M, Sheng K. Multimodality image registration in the head-and-neck using a deep learning-derived synthetic CT as a bridge. Med Phys. 2020;47:1094\u2013104.","journal-title":"Med Phys"},{"key":"2306_CR25","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s41747-018-0060-7","volume":"2","author":"F Galbusera","year":"2018","unstructured":"Galbusera F, Bassani T, Casaroli G, Gitto S, Zanchetta E, Tta E, Costa F, et al. Generative models: an upcoming innovation in musculoskeletal radiology? A preliminary test in spine imaging. Eur Radiol Exp. 2018;2:1\u201313.","journal-title":"Eur Radiol Exp"}],"container-title":["Radiation Oncology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13014-023-02306-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s13014-023-02306-4\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13014-023-02306-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,7,1]],"date-time":"2023-07-01T10:02:26Z","timestamp":1688205746000},"score":1,"resource":{"primary":{"URL":"https:\/\/ro-journal.biomedcentral.com\/articles\/10.1186\/s13014-023-02306-4"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,7,1]]},"references-count":25,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2023,12]]}},"alternative-id":["2306"],"URL":"https:\/\/doi.org\/10.1186\/s13014-023-02306-4","relation":{},"ISSN":["1748-717X"],"issn-type":[{"value":"1748-717X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,7,1]]},"assertion":[{"value":"13 January 2023","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"21 June 2023","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"1 July 2023","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"For this study anonymized patient data was used. According to our local ethics committee this does not require ethics approval.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they have no competing interests.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"108"}}