{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,24]],"date-time":"2026-04-24T02:39:27Z","timestamp":1776998367665,"version":"3.51.4"},"reference-count":39,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2026,3,17]],"date-time":"2026-03-17T00:00:00Z","timestamp":1773705600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"},{"start":{"date-parts":[[2026,4,24]],"date-time":"2026-04-24T00:00:00Z","timestamp":1776988800000},"content-version":"vor","delay-in-days":38,"URL":"https:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0"}],"funder":[{"DOI":"10.13039\/501100003725","name":"National Research Foundation of Korea","doi-asserted-by":"publisher","award":["RS-2023-00211810"],"award-info":[{"award-number":["RS-2023-00211810"]}],"id":[{"id":"10.13039\/501100003725","id-type":"DOI","asserted-by":"publisher"}]},{"name":"Seoul National University Hospital, South Korea","award":["0420250540"],"award-info":[{"award-number":["0420250540"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Radiat Oncol"],"DOI":"10.1186\/s13014-026-02828-7","type":"journal-article","created":{"date-parts":[[2026,3,17]],"date-time":"2026-03-17T11:46:45Z","timestamp":1773748005000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":0,"title":["Dose calculation accuracy with extended CT scales near metal: phantom\u2013patient evaluation using a beam\u2013metal overlap metric"],"prefix":"10.1186","volume":"21","author":[{"given":"Minsoo","family":"Chun","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hosik","family":"Kim","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jaewon","family":"Hong","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jin Hwa","family":"Choi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Seungwan","family":"Lee","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Inbum","family":"Lee","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jung-in","family":"Kim","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Seonghee","family":"Kang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2026,3,17]]},"reference":[{"key":"2828_CR1","doi-asserted-by":"publisher","first-page":"e13641","DOI":"10.1002\/acm2.13641","volume":"23","author":"MW Geurts","year":"2022","unstructured":"Geurts MW, Jacqmin DJ, Jones LE, Kry SF, Mihailidis DN, Ohrt JD, et al. AAPM medical physics practice guideline 5. b: Commissioning and QA of treatment planning dose calculations\u2014Megavoltage photon and electron beams. J Appl Clin Med Phys. 2022;23:e13641.","journal-title":"J Appl Clin Med Phys"},{"key":"2828_CR2","doi-asserted-by":"crossref","unstructured":"Papanikolaou N, Battista J, Boyer A, Kappas C, Klein E, Mackie T, et al. Tissue inhomogeneity corrections for megavoltage photon beams AAPM Report 85. Medical Physics Pub for AAPM, New York. 2004:8.","DOI":"10.37206\/86"},{"key":"2828_CR3","doi-asserted-by":"publisher","first-page":"459","DOI":"10.1088\/0031-9155\/45\/2\/314","volume":"45","author":"W Schneider","year":"2000","unstructured":"Schneider W, Bortfeld T, Schlegel W. Correlation between CT numbers and tissue parameters needed for Monte Carlo simulations of clinical dose distributions. Phys Med Biol. 2000;45:459.","journal-title":"Phys Med Biol"},{"key":"2828_CR4","doi-asserted-by":"publisher","first-page":"145","DOI":"10.1016\/j.meddos.2005.05.001","volume":"30","author":"CB Saw","year":"2005","unstructured":"Saw CB, Loper A, Komanduri K, Combine T, Huq S, Scicutella C. Determination of CT-to-density conversion relationship for image-based treatment planning systems. Med Dosim. 2005;30:145\u20138.","journal-title":"Med Dosim"},{"key":"2828_CR5","doi-asserted-by":"publisher","first-page":"1195","DOI":"10.1118\/1.598297","volume":"25","author":"F Du Plessis","year":"1998","unstructured":"Du Plessis F, Willemse C, L\u00f6tter M, Goedhals L. The indirect use of CT numbers to establish material properties needed for Monte Carlo calculation of dose distributions in patients. Med Phys. 1998;25:1195\u2013201.","journal-title":"Med Phys"},{"key":"2828_CR6","doi-asserted-by":"publisher","first-page":"271","DOI":"10.1002\/acm2.12226","volume":"19","author":"M Nakao","year":"2018","unstructured":"Nakao M, Ozawa S, Yamada K, Yogo K, Hosono F, Hayata M, et al. Tolerance levels of CT number to electron density table for photon beam in radiotherapy treatment planning system. J Appl Clin Med Phys. 2018;19:271\u20135.","journal-title":"J Appl Clin Med Phys"},{"key":"2828_CR7","doi-asserted-by":"publisher","first-page":"499","DOI":"10.1016\/j.rpor.2019.07.013","volume":"24","author":"D Kawahara","year":"2019","unstructured":"Kawahara D, Ozawa S, Yokomachi K, Higaki T, Shiinoki T, Ohno Y, et al. Evaluation of raw-data-based and calculated electron density for contrast media with a dual-energy CT technique. Rep Pract Oncol Radiother. 2019;24:499\u2013506.","journal-title":"Rep Pract Oncol Radiother"},{"key":"2828_CR8","doi-asserted-by":"publisher","first-page":"188","DOI":"10.1177\/1533034616649530","volume":"16","author":"N Xin-Ye","year":"2017","unstructured":"Xin-Ye N, Liugang G, Mingming F, Tao L. Application of metal implant 16-bit imaging: new technique in radiotherapy. Technol Cancer Res Treat. 2017;16:188\u201394.","journal-title":"Technol Cancer Res Treat"},{"key":"2828_CR9","doi-asserted-by":"publisher","first-page":"179","DOI":"10.1120\/jacmp.v17i6.6153","volume":"17","author":"JP Mullins","year":"2016","unstructured":"Mullins JP, Grams MP, Herman MG, Brinkmann DH, Antolak JA. Treatment planning for metals using an extended CT number scale. J Appl Clin Med Phys. 2016;17:179\u201388.","journal-title":"J Appl Clin Med Phys"},{"key":"2828_CR10","doi-asserted-by":"publisher","first-page":"061711","DOI":"10.1118\/1.4805102","volume":"40","author":"C Glide-Hurst","year":"2013","unstructured":"Glide-Hurst C, Chen D, Zhong H, Chetty I. Changes realized from extended bit\u2010depth and metal artifact reduction in CT. Med Phys. 2013;40:061711.","journal-title":"Med Phys"},{"key":"2828_CR11","doi-asserted-by":"publisher","first-page":"2119","DOI":"10.1118\/1.2736777","volume":"34","author":"M Bazalova","year":"2007","unstructured":"Bazalova M, Beaulieu L, Palefsky S, Verhaegen F. Correction of CT artifacts and its influence on Monte Carlo dose calculations. Med Phys. 2007;34:2119\u201332.","journal-title":"Med Phys"},{"key":"2828_CR12","doi-asserted-by":"publisher","first-page":"5117","DOI":"10.1118\/1.4960632","volume":"43","author":"JY Huang","year":"2016","unstructured":"Huang JY, Followill DS, Howell RM, Liu X, Mirkovic D, Stingo FC, et al. Approaches to reducing photon dose calculation errors near metal implants. Med Phys. 2016;43:5117\u201330.","journal-title":"Med Phys"},{"key":"2828_CR13","doi-asserted-by":"publisher","first-page":"9","DOI":"10.1002\/acm2.12060","volume":"18","author":"D Paulu","year":"2017","unstructured":"Paulu D, Alaei P. Evaluation of dose calculation accuracy of treatment planning systems at hip prosthesis interfaces. J Appl Clin Med Phys. 2017;18:9\u201315.","journal-title":"J Appl Clin Med Phys"},{"key":"2828_CR14","doi-asserted-by":"publisher","first-page":"5974","DOI":"10.1038\/s41598-022-10072-8","volume":"12","author":"B Pawa\u0142owski","year":"2022","unstructured":"Pawa\u0142owski B, Ryczkowski A, Panek R, Sobocka-Kurdyk U, Graczyk K, Piotrowski T. Accuracy of the doses computed by the Eclipse treatment planning system near and inside metal elements. Sci Rep. 2022;12:5974.","journal-title":"Sci Rep"},{"key":"2828_CR15","doi-asserted-by":"publisher","first-page":"479","DOI":"10.1016\/j.radonc.2017.09.029","volume":"126","author":"DG Kovacs","year":"2018","unstructured":"Kovacs DG, Rechner LA, Appelt AL, Berthelsen AK, Costa JC, Friborg J, et al. Metal artefact reduction for accurate tumour delineation in radiotherapy. Radiother Oncol. 2018;126:479\u201386.","journal-title":"Radiother Oncol"},{"key":"2828_CR16","doi-asserted-by":"publisher","first-page":"100","DOI":"10.14407\/jrpr.2023.00038","volume":"48","author":"H Lee","year":"2023","unstructured":"Lee H, Oh DH, Yoo L, Chun M. Assessment of Temporary Radioactivation for Tissue Expanders in Breast Radiation Therapy: Preliminary Study. J Radiat Prot Res. 2023;48:100\u20136.","journal-title":"J Radiat Prot Res"},{"key":"2828_CR17","doi-asserted-by":"publisher","first-page":"236","DOI":"10.3857\/roj.2020.00738","volume":"38","author":"G Yang","year":"2020","unstructured":"Yang G, Chang JS, Shin KH, Kim JH, Park W, Kim H, et al. Post-mastectomy radiation therapy in breast reconstruction: a patterns of care study of the Korean Radiation Oncology Group. Radiat Oncol J. 2020;38:236.","journal-title":"Radiat Oncol J"},{"key":"2828_CR18","doi-asserted-by":"publisher","first-page":"205","DOI":"10.1002\/acm2.12320","volume":"19","author":"J Yoon","year":"2018","unstructured":"Yoon J, Xie Y, Heins D, Zhang R. Modeling of the metallic port in breast tissue expanders for photon radiotherapy. J Appl Clin Med Phys. 2018;19:205\u201314.","journal-title":"J Appl Clin Med Phys"},{"key":"2828_CR19","doi-asserted-by":"publisher","first-page":"62","DOI":"10.1002\/acm2.12046","volume":"18","author":"A Nevelsky","year":"2017","unstructured":"Nevelsky A, Borzov E, Daniel S, Bar-Deroma R. Perturbation effects of the carbon fiber\u2010PEEK screws on radiotherapy dose distribution. J Appl Clin Med Phys. 2017;18:62\u20138.","journal-title":"J Appl Clin Med Phys"},{"key":"2828_CR20","doi-asserted-by":"publisher","first-page":"201","DOI":"10.1016\/j.ejmp.2020.10.015","volume":"80","author":"A Delana","year":"2020","unstructured":"Delana A, Barbareschi A, Consorti R, Falco MD. Dose calculation accuracy in proximity of a pacemaker: A multicenter study with threecommercial treatment planning systems. Phys Med. 2020;80:201\u20138.","journal-title":"Phys Med"},{"key":"2828_CR21","doi-asserted-by":"publisher","first-page":"285","DOI":"10.1017\/S1460396919000013","volume":"18","author":"J Jayamani","year":"2019","unstructured":"Jayamani J, Osman ND, Tajuddin AA, Salehi Z, Ali MH, Aziz MZA. Determination of computed tomography number of high-density materials in 12-bit, 12-bit extended and 16-bit depth for dosimetric calculation in treatment planning system. J Radiother Pract. 2019;18:285\u201394.","journal-title":"J Radiother Pract"},{"key":"2828_CR22","doi-asserted-by":"publisher","first-page":"597","DOI":"10.1515\/cdbme-2019-0150","volume":"5","author":"Z Ese","year":"2019","unstructured":"Ese Z, Zylka W. Influence of 12-bit and 16-bit CT values of metals on dose calculation in radiotherapy using PRIMO, a Monte Carlo code for clinical linear accelerators. Curr Dir Biomed Eng. 2019;5:597\u2013600.","journal-title":"Curr Dir Biomed Eng"},{"key":"2828_CR23","first-page":"496","volume":"13","author":"J Jayamani","year":"2020","unstructured":"Jayamani J, Osman N, Tajuddin A, Noor NM, Aziz MA. Dosimetric comparison between Monaco TPS and EGSnrc Monte Carlo simulation on titanium rod in 12bit and 16bit image format. J Radiat Res Appl Sci. 2020;13:496\u2013506.","journal-title":"J Radiat Res Appl Sci"},{"key":"2828_CR24","doi-asserted-by":"publisher","first-page":"100510","DOI":"10.1016\/j.phro.2023.100510","volume":"28","author":"M Grohmann","year":"2023","unstructured":"Grohmann M, Petersen C, Todorovic M. Benefits and considerations in using a novel computed tomography system optimized for radiotherapy planning. Phys Imaging Radiat Oncol. 2023;28:100510.","journal-title":"Phys Imaging Radiat Oncol"},{"key":"2828_CR25","first-page":"2373","volume":"15","author":"L Gao","year":"2018","unstructured":"Gao L, Sun H, Ni X, Fang M, Lin T. Effects of 16-bit CT imaging scanning conditions for metal implants on radiotherapy dose distribution. Oncol Lett. 2018;15:2373\u20139.","journal-title":"Oncol Lett"},{"key":"2828_CR26","doi-asserted-by":"publisher","first-page":"49","DOI":"10.1016\/j.meddos.2003.10.005","volume":"29","author":"J Moni","year":"2004","unstructured":"Moni J, Graves-Ditman M, Cederna P, Griffith K, Krueger EA, Fraass BA, et al. Dosimetry around metallic ports in tissue expanders in patients receiving postmastectomy radiation therapy: an ex vivo evaluation. Med Dosim. 2004;29:49\u201354.","journal-title":"Med Dosim"},{"key":"2828_CR27","doi-asserted-by":"publisher","first-page":"5986","DOI":"10.1002\/mp.14497","volume":"47","author":"A Niroomand-Rad","year":"2020","unstructured":"Niroomand-Rad A, Chiu\u2010Tsao ST, Grams MP, Lewis DF, Soares CG, Van Battum LJ, et al. Report of AAPM task group 235 radiochromic film dosimetry: an update to TG\u201055. Med Phys. 2020;47:5986\u20136025.","journal-title":"Med Phys"},{"key":"2828_CR28","doi-asserted-by":"publisher","first-page":"175003","DOI":"10.1088\/1361-6560\/aceb48","volume":"68","author":"AL Palmer","year":"2023","unstructured":"Palmer AL, Nash D, Polak W, Wilby S. Evaluation of a new radiochromic film dosimeter, Gafchomic EBT4, for VMAT, SABR and HDR treatment delivery verification. Phys Med Biol. 2023;68:175003.","journal-title":"Phys Med Biol"},{"key":"2828_CR29","doi-asserted-by":"publisher","first-page":"1847","DOI":"10.1118\/1.598691","volume":"26","author":"PR Almond","year":"1999","unstructured":"Almond PR, Biggs PJ, Coursey BM, Hanson WF, Huq MS, Nath R, et al. AAPM\u2019s TG-51 protocol for clinical reference dosimetry of high\u2010energy photon and electron beams. Med Phys. 1999;26:1847\u201370.","journal-title":"Med Phys"},{"key":"2828_CR30","doi-asserted-by":"publisher","first-page":"234","DOI":"10.1120\/jacmp.v17i1.5870","volume":"17","author":"T Kamomae","year":"2016","unstructured":"Kamomae T, Itoh Y, Okudaira K, Nakaya T, Tomida M, Miyake Y, et al. Dosimetric impact of dental metallic crown on intensity-modulated radiotherapy and volumetric\u2010modulated arc therapy for head and neck cancer. J Appl Clin Med Phys. 2016;17:234\u201345.","journal-title":"J Appl Clin Med Phys"},{"key":"2828_CR31","doi-asserted-by":"publisher","first-page":"310","DOI":"10.1118\/1.2818738","volume":"35","author":"K Otto","year":"2008","unstructured":"Otto K. Volumetric modulated arc therapy: IMRT in a single gantry arc. Med Phys. 2008;35:310\u20137.","journal-title":"Med Phys"},{"key":"2828_CR32","doi-asserted-by":"publisher","first-page":"5128","DOI":"10.1118\/1.3240488","volume":"36","author":"JL Bedford","year":"2009","unstructured":"Bedford JL. Treatment planning for volumetric modulated arc therapy. Med Phys. 2009;36:5128\u201338.","journal-title":"Med Phys"},{"key":"2828_CR33","doi-asserted-by":"publisher","first-page":"65","DOI":"10.14316\/pmp.2024.35.3.65","volume":"35","author":"S Kang","year":"2024","unstructured":"Kang S, Ryu H, Oh DH, Yoo L, Chun M. Impact of smaller gantry Arc increments on volumetric modulated Arc radiation therapy in the Monaco treatment planning system. Prog Med Phys. 2024;35:65\u201372.","journal-title":"Prog Med Phys"},{"key":"2828_CR34","doi-asserted-by":"crossref","unstructured":"Choi JH, Park H, Oh DH, Ryu H, Yoo L, Chun M. Organs-at-risk dose reduction with dual gantry arc increment values in VMAT for prostate cancer. Radiat Phys Chem. 2025:113020.","DOI":"10.1016\/j.radphyschem.2025.113020"},{"key":"2828_CR35","doi-asserted-by":"publisher","first-page":"e14571","DOI":"10.1002\/acm2.14571","volume":"26","author":"JH Choi","year":"2025","unstructured":"Choi JH, Ryu H, Oh DH, Yoo L, Chun M. Dosimetric advantages of dual arc increments for head and neck volumetric-modulated arc therapy in the Monaco treatment planning system. J Appl Clin Med Phys. 2025;26:e14571.","journal-title":"J Appl Clin Med Phys"},{"key":"2828_CR36","doi-asserted-by":"publisher","first-page":"14","DOI":"10.1120\/jacmp.v16i5.5768","volume":"16","author":"JB Smilowitz","year":"2015","unstructured":"Smilowitz JB, Das IJ, Feygelman V, Fraass BA, Kry SF, Marshall IR, et al. AAPM medical physics practice guideline 5. a.: commissioning and QA of treatment planning dose calculations\u2014megavoltage photon and electron beams. J Appl Clin Med Phys. 2015;16:14\u201334.","journal-title":"J Appl Clin Med Phys"},{"key":"2828_CR37","doi-asserted-by":"publisher","first-page":"1466","DOI":"10.1118\/1.598676","volume":"26","author":"M Fippel","year":"1999","unstructured":"Fippel M. Fast Monte Carlo dose calculation for photon beams based on the VMC electron algorithm. Med Phys. 1999;26:1466\u201375.","journal-title":"Med Phys"},{"key":"2828_CR38","doi-asserted-by":"publisher","first-page":"230","DOI":"10.1120\/jacmp.v17i6.6455","volume":"17","author":"MR Paudel","year":"2016","unstructured":"Paudel MR, Kim A, Sarfehnia A, Ahmad SB, Beachey DJ, Sahgal A, et al. Experimental evaluation of a GPU-based Monte Carlo dose calculation algorithm in the Monaco treatment planning system. J Appl Clin Med Phys. 2016;17:230\u201341.","journal-title":"J Appl Clin Med Phys"},{"key":"2828_CR39","doi-asserted-by":"publisher","first-page":"100636","DOI":"10.1016\/j.phro.2024.100636","volume":"32","author":"TZ Jagt","year":"2024","unstructured":"Jagt TZ, Janssen TM, Sonke J-J. Evaluating the effect of higher Monte Carlo statistical uncertainties on accumulated doses after daily adaptive fractionated radiotherapy in prostate cancer. Phys Imaging Radiat Oncol. 2024;32:100636.","journal-title":"Phys Imaging Radiat Oncol"}],"container-title":["Radiation Oncology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s13014-026-02828-7","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13014-026-02828-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13014-026-02828-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,24]],"date-time":"2026-04-24T01:53:11Z","timestamp":1776995591000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1186\/s13014-026-02828-7"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,3,17]]},"references-count":39,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2026,12]]}},"alternative-id":["2828"],"URL":"https:\/\/doi.org\/10.1186\/s13014-026-02828-7","relation":{},"ISSN":["1748-717X"],"issn-type":[{"value":"1748-717X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,3,17]]},"assertion":[{"value":"1 October 2025","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"9 March 2026","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"17 March 2026","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This study was approved by the Institutional Review Board of Chung-Ang University Gwangmyeong Hospital (IRB No. 2405-164-068), and the requirement for informed consent was waived owing to the retrospective nature of the study. All procedures were conducted in accordance with the Declaration of Helsinki.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"The authors declare no competing interests.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"61"}}