{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,10]],"date-time":"2026-09-10T06:13:36Z","timestamp":1789020816549,"version":"build-2803163510"},"reference-count":31,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2018,11,27]],"date-time":"2018-11-27T00:00:00Z","timestamp":1543276800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Orthop Surg Res"],"published-print":{"date-parts":[[2018,12]]},"DOI":"10.1186\/s13018-018-1011-y","type":"journal-article","created":{"date-parts":[[2018,11,27]],"date-time":"2018-11-27T10:21:31Z","timestamp":1543314091000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":14,"title":["Mechanical simulation study of postoperative displacement of trochanteric fractures using the finite element method"],"prefix":"10.1186","volume":"13","author":[{"given":"Atsuo","family":"Furui","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nobuki","family":"Terada","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kazuaki","family":"Mito","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2018,11,27]]},"reference":[{"key":"1011_CR1","doi-asserted-by":"publisher","first-page":"15","DOI":"10.4103\/0019-5413.73656","volume":"45","author":"DK Dhanwal","year":"2011","unstructured":"Dhanwal DK, Dennison EM, Harvey NC, Cooper C. Epidemiology of hip fracture: worldwide geographic variation. Indian J Orthop. 2011;45:15\u201322.","journal-title":"Indian J Orthop"},{"key":"1011_CR2","doi-asserted-by":"publisher","first-page":"361","DOI":"10.1302\/0301-620X.87B3.15300","volume":"87","author":"I Weller","year":"2005","unstructured":"Weller I, Wai EK, Jaglal S, Kreder HJ. The effect of hospital type and surgical delay on mortality after surgery for hip fracture. J Bone Joint Surg Br. 2005;87:361\u20136.","journal-title":"J Bone Joint Surg Br"},{"key":"1011_CR3","first-page":"409","volume-title":"Proximal femoral fractures. Operative techniques and complications. Vol. 2","author":"J Luitse","year":"1993","unstructured":"Luitse J, Dunki Jacobs PB, van der Hart CP. The dynamic hip screw: \u201cgolden standard\u201d in the treatment pf pertrochanteric fractures? In: Proximal femoral fractures. Operative techniques and complications. Vol. 2. London: Medical press; 1993. p. 409\u201322."},{"key":"1011_CR4","doi-asserted-by":"publisher","first-page":"792","DOI":"10.2106\/JBJS.I.00508","volume":"92","author":"TM Barton","year":"2010","unstructured":"Barton TM, Gleeson R, Topliss C, Greenwood R, Harries WJ, Chesser TJ. A comparison of the long gamma nail with the sliding hip screw for the treatment of AO\/OTA 31-A2 fractures of the proximal part of the femur: a prospective randomized trial. J Bone Joint Surg Am. 2010;92:792\u20138.","journal-title":"J Bone Joint Surg Am"},{"issue":"9","key":"1011_CR5","first-page":"CD000093","volume":"8","author":"MJ Parker","year":"2010","unstructured":"Parker MJ, Handoll HH. Gamma and other cephalocondylic intramedullary nails versus extramedullary implants for extracapsular hip fractures in adults. Cochrane Database Syst Rev. 2010;8(9):CD000093.","journal-title":"Cochrane Database Syst Rev"},{"key":"1011_CR6","doi-asserted-by":"publisher","first-page":"125","DOI":"10.1007\/s00264-009-0744-y","volume":"34","author":"RK Gupta","year":"2010","unstructured":"Gupta RK, Sangwan K, Kamboj P, Punia SS, Walecha P. Unstable trochanteric fractures: the role of lateral wall reconstruction. Int Orthop. 2010;34:125\u20139.","journal-title":"Int Orthop"},{"key":"1011_CR7","doi-asserted-by":"crossref","first-page":"15","DOI":"10.55095\/achot2013\/003","volume":"80","author":"P Dou\u0161a","year":"2013","unstructured":"Dou\u0161a P, \u010cech O, Weissinger M, D\u017eupa V. Trochanteric femoral fractures. Acta Chir Orthop Traumatol Cechoslov. 2013;80:15\u201326.","journal-title":"Acta Chir Orthop Traumatol Cechoslov"},{"key":"1011_CR8","doi-asserted-by":"publisher","first-page":"1364","DOI":"10.1080\/10255842.2017.1363192","volume":"20","author":"L Necas","year":"2017","unstructured":"Necas L, Hrubina M, Cibula Z, Behounek J Jr, Krivanek S, Horak Z. Fatigue failure of the sliding hip screw - clinical and biomechanical analysis. Comput Methods Biomech Biomed Engin. 2017;20:1364\u201372.","journal-title":"Comput Methods Biomech Biomed Engin"},{"key":"1011_CR9","doi-asserted-by":"publisher","first-page":"e127","DOI":"10.1097\/BOT.0b013e318278112a","volume":"27","author":"M Knobe","year":"2013","unstructured":"Knobe M, Gradl G, Maier KJ, Drescher W, Jansen-Troy A, Prescher A, et al. Rotationally stable screw-anchor versus sliding hip screw plate systems in stable trochanteric femur fractures: a biomechanical evaluation. J Orthop Trauma. 2013;27:e127\u201336.","journal-title":"J Orthop Trauma"},{"key":"1011_CR10","doi-asserted-by":"publisher","first-page":"706","DOI":"10.2106\/00004623-196345040-00003","volume":"45","author":"A Sarmiento","year":"1963","unstructured":"Sarmiento A. Intertrochanteric fractures of the femur. J Bone Joint Surg. 1963;45:706\u201322.","journal-title":"J Bone Joint Surg"},{"key":"1011_CR11","first-page":"269","volume":"71","author":"A Furui","year":"2017","unstructured":"Furui A, Terada N. Analysis of the postoperative displacement of trochanteric fractures on lateral view radiographs. Acta Med Okayama. 2017;71:269\u201377.","journal-title":"Acta Med Okayama"},{"key":"1011_CR12","first-page":"158","volume":"24","author":"T Ikuta","year":"2002","unstructured":"Ikuta T. Classification of trochanteric fracture of the femur. Kossetsu. 2002;24:158\u201362 (in Japanese).","journal-title":"Kossetsu"},{"key":"1011_CR13","doi-asserted-by":"publisher","first-page":"18","DOI":"10.5301\/HIP.2008.2049","volume":"14","author":"B Seral","year":"2004","unstructured":"Seral B, Garca JM, Cegoino J, Doblare M, Seral F. 3D finite element analysis of the gamma nail and DHS plate in trochanteric hip fractures. Hip Int. 2004;14:18\u201323.","journal-title":"Hip Int"},{"key":"1011_CR14","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1115\/1.2146001","volume":"128","author":"R Zauel","year":"2006","unstructured":"Zauel R, Yeni YN, Bay BK, Dong XN, Fyhrie DP. Comparison of the linear finite element prediction of deformation and strain of human cancellous bone to 3D digital volume correlation measurements. J Biomech Eng. 2006;128:1\u20136.","journal-title":"J Biomech Eng"},{"key":"1011_CR15","doi-asserted-by":"publisher","first-page":"596","DOI":"10.1002\/jor.22266","volume":"31","author":"JM Goffin","year":"2012","unstructured":"Goffin JM, Pankaj P, Simpson AH. The importance of lag screw position for the stabilization of trochanteric fractures with a sliding hip screw: a subject-specific finite element study. J Orthop Res. 2012;31:596\u2013600.","journal-title":"J Orthop Res"},{"key":"1011_CR16","doi-asserted-by":"publisher","first-page":"255","DOI":"10.1016\/j.clinbiomech.2003.12.003","volume":"19","author":"WP Chen","year":"2004","unstructured":"Chen WP, Tai CL, Shih CH, Hsieh PH, Leou MC, Lee MS. Selection of fixation devices in proximal femur rotational osteotomy: clinical complications and finite element analysis. Clin Biomech (Bristol, Avon). 2004;19:255\u201362.","journal-title":"Clin Biomech (Bristol, Avon)"},{"key":"1011_CR17","unstructured":"Jacobs CR. Numerical simulation of bone adaptation to mechanical loading. Dissertation for the degree of doctor of Philosophy 1994."},{"key":"1011_CR18","doi-asserted-by":"publisher","first-page":"1325","DOI":"10.1016\/S0021-9290(00)00069-5","volume":"33","author":"DC Wirtz","year":"2000","unstructured":"Wirtz DC, Schiffers N, Pandorf T, Radermacher K, Weichert D, Forst R. Critical evaluation of known bone material properties to realize anisotropic FE-simulation of the proximal femur. J Biomech. 2000;33:1325\u201330.","journal-title":"J Biomech"},{"key":"1011_CR19","doi-asserted-by":"publisher","first-page":"134","DOI":"10.1002\/jor.1100100116","volume":"10","author":"TP Harrigan","year":"1992","unstructured":"Harrigan TP, Kareh JA, O\u2019Connor DO, Burke DW, Harris WH. A finite element study of the initiation of failure of fixation in cemented femoral total hip components. J Orthop Res. 1992;10:134\u201344.","journal-title":"J Orthop Res"},{"key":"1011_CR20","doi-asserted-by":"publisher","first-page":"167","DOI":"10.1002\/jbm.820270205","volume":"27","author":"A Shirazi-Adl","year":"1993","unstructured":"Shirazi-Adl A, Dammak M, Paiement G. Experimental determination of friction characteristics at the trabecular bone\/porous-coated metal interface in cementless implants. J Biomed Mater Res. 1993;27:167\u201375.","journal-title":"J Biomed Mater Res"},{"key":"1011_CR21","doi-asserted-by":"publisher","first-page":"1611","DOI":"10.1016\/S0021-9290(00)00140-8","volume":"33","author":"M Viceconti","year":"2000","unstructured":"Viceconti M, Muccini R, Bernakiewicz M, Baleani M, Cristofolini L. Large-sliding contact elements accurately predict levels of bone\u2013implant micromotion relevant to osseointegration. J Biomech. 2000;33:1611\u20138.","journal-title":"J Biomech"},{"key":"1011_CR22","doi-asserted-by":"publisher","first-page":"167","DOI":"10.1002\/(SICI)1097-4636(199606)31:2<167::AID-JBM3>3.0.CO;2-L","volume":"31","author":"M Akay","year":"1996","unstructured":"Akay M, Aslan N. Numerical and experimental stress analysis of a polymeric composite hip joint prosthesis. J Biomed Mater Res. 1996;31:167\u201382.","journal-title":"J Biomed Mater Res"},{"key":"1011_CR23","first-page":"1130","volume":"31","author":"H Pan","year":"2010","unstructured":"Pan H, Chen B, Deng LF. Biomechanical effects of the Coflex implantation on the lumbar spine. A nonlinear finite element analysis. Saudi Med J. 2010;31:1130\u20136.","journal-title":"Saudi Med J"},{"key":"1011_CR24","first-page":"732","volume":"33","author":"GX Yuan","year":"2012","unstructured":"Yuan GX, Shen YH, Chen B, Zhang WB. Biomechanical comparison of internal fixations in osteoporotic intertrochanteric fracture. A finite element analysis. Saudi Med J. 2012;33:732\u20139.","journal-title":"Saudi Med J."},{"key":"1011_CR25","first-page":"345","volume":"35","author":"N Shiota","year":"2013","unstructured":"Shiota N, Sato T, Tetsunaga T, Yoshida M, Mochizuki Y, Yamada K, et al. Evaluation of intraoperative reduction for femoral intertrochanteric fractures. Kossetsu. 2013;35:345\u20138 (in Japanese).","journal-title":"Kossetsu."},{"key":"1011_CR26","first-page":"302","volume":"116","author":"M Hrubina","year":"2015","unstructured":"Hrubina M, Horak Z, Skotak M, Letocha J, Baca V, Dzupa V. Assessment of complications depending on the sliding screw position - finite element method analysis. Bratisl Lek Listy. 2015;116:302\u201310.","journal-title":"Bratisl Lek Listy"},{"key":"1011_CR27","doi-asserted-by":"publisher","first-page":"39","DOI":"10.1002\/jor.22469","volume":"32","author":"JM Goffin","year":"2014","unstructured":"Goffin JM, Pankaj P, Simpson AH. A computational study on the effect of fracture intrusion distance in three- and four-part trochanteric fractures treated with Gamma nail and sliding hip screw. J Orthop Re. 2014;32:39\u201345.","journal-title":"J Orthop Re"},{"key":"1011_CR28","doi-asserted-by":"publisher","first-page":"1621","DOI":"10.1016\/S0142-9612(97)00146-4","volume":"19","author":"M Long","year":"1998","unstructured":"Long M, Rack HJ. Titanium alloys in total joint replacement--a materials science perspective. Biomaterials. 1998;19:1621\u201339.","journal-title":"Biomaterials"},{"key":"1011_CR29","doi-asserted-by":"crossref","unstructured":"Celik T, Mutlu I, Ozkan A, Kisioglu Y. Comparison of the lag screw placements for the treatment of stable and unstable intertrochanteric femoral fractures regarding trabecular bone failure. J Med Eng. 2016;22.","DOI":"10.1155\/2016\/5470798"},{"key":"1011_CR30","doi-asserted-by":"publisher","first-page":"1058","DOI":"10.2106\/00004623-199507000-00012","volume":"77","author":"MR Baumgaertner","year":"1995","unstructured":"Baumgaertner MR, Curtin SL, Lindskog DM, Keggi JM. The value of the tip\u2013apex distance in predicting failure of fixation of peritrochanteric fractures of the hip. J Bone Joint Surg Am. 1995;77:1058\u201364.","journal-title":"J Bone Joint Surg Am"},{"key":"1011_CR31","doi-asserted-by":"publisher","first-page":"681","DOI":"10.1177\/0954411912447011","volume":"226","author":"L Konstantinidis","year":"2012","unstructured":"Konstantinidis L, Papaioannou C, Hirschm\u00fcller A, Pavlidis T, Schr\u00f6ter S, S\u00fcdkamp NP, et al. Effects of muscle-equivalent forces on the biomechanical behavior of proximal femur fracture models: a pilot study on artificial bones. Proc Inst Mech Eng H. 2012;226:681\u20135.","journal-title":"Proc Inst Mech Eng H"}],"container-title":["Journal of Orthopaedic Surgery and Research"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s13018-018-1011-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1186\/s13018-018-1011-y\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s13018-018-1011-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,7]],"date-time":"2023-09-07T15:28:06Z","timestamp":1694100486000},"score":1,"resource":{"primary":{"URL":"https:\/\/josr-online.biomedcentral.com\/articles\/10.1186\/s13018-018-1011-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,11,27]]},"references-count":31,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2018,12]]}},"alternative-id":["1011"],"URL":"https:\/\/doi.org\/10.1186\/s13018-018-1011-y","relation":{},"ISSN":["1749-799X"],"issn-type":[{"value":"1749-799X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,11,27]]},"assertion":[{"value":"13 September 2018","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"19 November 2018","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"27 November 2018","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The study was approved by the ethics committee of Fujita Health University (HM18-078). The patient gave her consent to participate in this study.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"No benefits in any form have been received or will be received from any commercial party related directly or indirectly to the subject of this article. The authors declare that they have no competing interests.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}},{"value":"Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Publisher\u2019s Note"}}],"article-number":"300"}}