{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T02:40:02Z","timestamp":1787020802516,"version":"build-2736575974"},"reference-count":24,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2019,2,15]],"date-time":"2019-02-15T00:00:00Z","timestamp":1550188800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Orthop Surg Res"],"published-print":{"date-parts":[[2019,12]]},"DOI":"10.1186\/s13018-019-1088-y","type":"journal-article","created":{"date-parts":[[2019,2,15]],"date-time":"2019-02-15T04:04:11Z","timestamp":1550203451000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":17,"title":["The impact of plate length, fibula integrity and plate placement on tibial shaft fixation stability: a finite element study"],"prefix":"10.1186","volume":"14","author":[{"given":"Yasen","family":"Cao","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yong","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lixin","family":"Huang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xiaowei","family":"Huang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2019,2,15]]},"reference":[{"issue":"7","key":"1088_CR1","doi-asserted-by":"publisher","first-page":"e619","DOI":"10.3928\/01477447-20140626-52","volume":"37","author":"DM Economedes","year":"2014","unstructured":"Economedes DM, Abzug JM, Paryavi E, Herman MJ. Outcomes using titanium elastic nails for open and closed pediatric tibia fractures. Orthopedics. 2014;37(7):e619\u201324.","journal-title":"Orthopedics"},{"issue":"4","key":"1088_CR2","first-page":"256","volume":"43","author":"CP Coles","year":"2000","unstructured":"Coles CP, Gross M. Closed tibial shaft fractures: management and treatment complications. A review of the prospective literature. Can J Surg. 2000;43(4):256\u201362.","journal-title":"Can J Surg"},{"issue":"2","key":"1088_CR3","doi-asserted-by":"publisher","first-page":"140","DOI":"10.1097\/00005131-200502000-00012","volume":"19","author":"M Bhandari","year":"2005","unstructured":"Bhandari M, Zlowodzki M, Tornetta P 3rd, Schmidt A, Templeman DC. Intramedullary nailing following external fixation in femoral and tibial shaft fractures. J Orthop Trauma. 2005;19(2):140\u20134.","journal-title":"J Orthop Trauma"},{"issue":"4","key":"1088_CR4","first-page":"261","volume":"21","author":"P Huang","year":"2008","unstructured":"Huang P, Tang PF, Yao Q, Liang YT, Tao S, Zhang Q, et al. A comparisive study between intramedullary interlocking nail and plate-screw fixation in the treatment of tibial shaft fractures. Zhongguo Gu Shang. 2008;21(4):261\u20133.","journal-title":"Zhongguo Gu Shang"},{"issue":"4","key":"1088_CR5","doi-asserted-by":"publisher","first-page":"234","DOI":"10.6061\/clinics\/2014(04)03","volume":"69","author":"GC He","year":"2014","unstructured":"He GC, Wang HS, Wang QF, Chen ZH, Cai XH. Effect of minimally invasive percutaneous plates versus interlocking intramedullary nailing in tibial shaft treatment for fractures in adults: a meta-analysis. Clinics (Sao Paulo, Brazil). 2014;69(4):234\u201340.","journal-title":"Clinics (Sao Paulo, Brazil)"},{"key":"1088_CR6","unstructured":"Muller TS, Sommer C. [Reduction techniques for minimally invasive plate osteosynthesis]. Der Unfallchirurg. 2019;122(2):103-9."},{"key":"1088_CR7","doi-asserted-by":"publisher","first-page":"182","DOI":"10.1186\/s13018-015-0325-2","volume":"10","author":"X Huang","year":"2015","unstructured":"Huang X, Zhi Z, Yu B, Chen F. Stress and stability of plate-screw fixation and screw fixation in the treatment of Schatzker type IV medial tibial plateau fracture: a comparative finite element study. J Orthop Surg Res. 2015;10:182.","journal-title":"J Orthop Surg Res"},{"issue":"6","key":"1088_CR8","doi-asserted-by":"publisher","first-page":"898","DOI":"10.1016\/j.injury.2011.12.006","volume":"43","author":"RM Raja Izaham","year":"2012","unstructured":"Raja Izaham RM, Abdul Kadir MR, Abdul Rashid AH, Hossain MG, Kamarul T. Finite element analysis of Puddu and Tomofix plate fixation for open wedge high tibial osteotomy. Injury. 2012;43(6):898\u2013902.","journal-title":"Injury"},{"issue":"2","key":"1088_CR9","doi-asserted-by":"publisher","first-page":"209","DOI":"10.1016\/S0021-9290(99)00152-9","volume":"33","author":"JH Keyak","year":"2000","unstructured":"Keyak JH, Rossi SA. Prediction of femoral fracture load using finite element models: an examination of stress- and strain-based failure theories. J Biomech. 2000;33(2):209\u201314.","journal-title":"J Biomech"},{"issue":"1","key":"1088_CR10","doi-asserted-by":"publisher","first-page":"13","DOI":"10.1016\/S0021-9290(00)00169-X","volume":"34","author":"EC Teo","year":"2001","unstructured":"Teo EC, Ng HW. First cervical vertebra (atlas) fracture mechanism studies using finite element method. J Biomech. 2001;34(1):13\u201321.","journal-title":"J Biomech"},{"issue":"Suppl 1","key":"1088_CR11","doi-asserted-by":"publisher","first-page":"S7","DOI":"10.1016\/j.clinbiomech.2008.01.005","volume":"23","author":"Y Fan","year":"2008","unstructured":"Fan Y, Xiu K, Duan H, Zhang M. Biomechanical and histological evaluation of the application of biodegradable poly-L-lactic cushion to the plate internal fixation for bone fracture healing. Clinical biomechanics (Bristol, Avon). 2008;23(Suppl 1):S7\u2013s16.","journal-title":"Clinical biomechanics (Bristol, Avon)"},{"issue":"Suppl 3","key":"1088_CR12","doi-asserted-by":"publisher","first-page":"C21","DOI":"10.1016\/S0020-1383(00)80028-5","volume":"31","author":"J Cordey","year":"2000","unstructured":"Cordey J, Borgeaud M, Perren SM. Force transfer between the plate and the bone: relative importance of the bending stiffness of the screws friction between plate and bone. Injury. 2000;31(Suppl 3):C21\u20138.","journal-title":"Injury"},{"issue":"4","key":"1088_CR13","doi-asserted-by":"publisher","first-page":"305","DOI":"10.1016\/j.knee.2008.04.004","volume":"15","author":"C Kazimoglu","year":"2008","unstructured":"Kazimoglu C, Akdogan Y, Sener M, Kurtulmus A, Karapinar H, Uzun B. Which is the best fixation method for lateral cortex disruption in the medial open wedge high tibial osteotomy? A biomechanical study. Knee. 2008;15(4):305\u20138.","journal-title":"Knee"},{"issue":"Suppl 2","key":"1088_CR14","doi-asserted-by":"publisher","first-page":"B11","DOI":"10.1016\/j.injury.2003.09.021","volume":"34","author":"K Stoffel","year":"2003","unstructured":"Stoffel K, Dieter U, Stachowiak G, Gachter A, Kuster MS. Biomechanical testing of the LCP--how can stability in locked internal fixators be controlled? Injury. 2003;34(Suppl 2):B11\u20139.","journal-title":"Injury"},{"issue":"12","key":"1088_CR15","doi-asserted-by":"publisher","first-page":"2343","DOI":"10.2106\/00004623-200312000-00011","volume":"85-a","author":"F Leung","year":"2003","unstructured":"Leung F, Chow SP. A prospective, randomized trial comparing the limited contact dynamic compression plate with the point contact fixator for forearm fractures. J Bone Joint Surg Am. 2003;85-a(12):2343\u20138.","journal-title":"J Bone Joint Surg Am"},{"issue":"4","key":"1088_CR16","doi-asserted-by":"crossref","first-page":"462","DOI":"10.1002\/jor.20990","volume":"28","author":"JK Oh","year":"2010","unstructured":"Oh JK, Sahu D, Ahn YH, Lee SJ, Tsutsumi S, Hwang JH, et al. Effect of fracture gap on stability of compression plate fixation: a finite element study. J Orthop Res. 2010;28(4):462\u20137.","journal-title":"J Orthop Res"},{"issue":"Suppl 3","key":"1088_CR17","doi-asserted-by":"publisher","first-page":"S35","DOI":"10.1016\/j.injury.2007.08.009","volume":"38","author":"MA Miranda","year":"2007","unstructured":"Miranda MA. Locking plate technology and its role in osteoporotic fractures. Injury. 2007;38(Suppl 3):S35\u20139.","journal-title":"Injury"},{"issue":"10","key":"1088_CR18","doi-asserted-by":"publisher","first-page":"711","DOI":"10.5435\/JAAOS-D-15-00175","volume":"24","author":"MJ Beltran","year":"2016","unstructured":"Beltran MJ, Collinge CA, Gardner MJ. Stress modulation of fracture fixation implants. J Am Acad Orthop Surg. 2016;24(10):711\u20139.","journal-title":"J Am Acad Orthop Surg"},{"issue":"2","key":"1088_CR19","doi-asserted-by":"publisher","first-page":"83","DOI":"10.1097\/BOT.0b013e31829e6dd0","volume":"28","author":"WM Ricci","year":"2014","unstructured":"Ricci WM, Streubel PN, Morshed S, Collinge CA, Nork SE, Gardner MJ. Risk factors for failure of locked plate fixation of distal femur fractures: an analysis of 335 cases. J Orthop Trauma. 2014;28(2):83\u20139.","journal-title":"J Orthop Trauma"},{"issue":"10","key":"1088_CR20","doi-asserted-by":"publisher","first-page":"1049","DOI":"10.1016\/j.clinbiomech.2007.08.004","volume":"22","author":"DL Miller","year":"2007","unstructured":"Miller DL, Goswami T. A review of locking compression plate biomechanics and their advantages as internal fixators in fracture healing. Clin Biomech (Bristol, Avon). 2007;22(10):1049\u201362.","journal-title":"Clin Biomech (Bristol, Avon)"},{"issue":"5","key":"1088_CR21","doi-asserted-by":"publisher","first-page":"562","DOI":"10.1007\/s00776-012-0241-9","volume":"17","author":"OJ Shon","year":"2012","unstructured":"Shon OJ, Park CH. Minimally invasive plate osteosynthesis of distal tibial fractures: a comparison of medial and lateral plating. J Orthop Sci. 2012;17(5):562\u20136.","journal-title":"J Orthop Sci"},{"issue":"3","key":"1088_CR22","doi-asserted-by":"publisher","first-page":"33","DOI":"10.5704\/MOJ.1411.008","volume":"8","author":"IM Anuar-Ramdhan","year":"2014","unstructured":"Anuar-Ramdhan IM, Azahari IM, Med Orth M. Minimally invasive plate osteosynthesis with conventional compression plate for diaphyseal tibia fracture. Malays Orthop J. 2014;8(3):33\u20136.","journal-title":"Malays Orthop J"},{"key":"1088_CR23","first-page":"223","volume":"279","author":"JC Goh","year":"1992","unstructured":"Goh JC, Mech AM, Lee EH, Ang EJ, Bayon P, Pho RW. Biomechanical study on the load-bearing characteristics of the fibula and the effects of fibular resection. Clin Orthop Relat Res. 1992;279:223\u20138.","journal-title":"Clin Orthop Relat Res"},{"issue":"3","key":"1088_CR24","doi-asserted-by":"publisher","first-page":"206","DOI":"10.1097\/00005131-199704000-00012","volume":"11","author":"TG Weber","year":"1997","unstructured":"Weber TG, Harrington RM, Henley MB, Tencer AF. The role of fibular fixation in combined fractures of the tibia and fibula: a biomechanical investigation. J Orthop Trauma. 1997;11(3):206\u201311.","journal-title":"J Orthop Trauma"}],"container-title":["Journal of Orthopaedic Surgery and Research"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s13018-019-1088-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1186\/s13018-019-1088-y\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s13018-019-1088-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,11,27]],"date-time":"2020-11-27T16:41:33Z","timestamp":1606495293000},"score":1,"resource":{"primary":{"URL":"https:\/\/josr-online.biomedcentral.com\/articles\/10.1186\/s13018-019-1088-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,2,15]]},"references-count":24,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2019,12]]}},"alternative-id":["1088"],"URL":"https:\/\/doi.org\/10.1186\/s13018-019-1088-y","relation":{},"ISSN":["1749-799X"],"issn-type":[{"value":"1749-799X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,2,15]]},"assertion":[{"value":"9 December 2018","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"5 February 2019","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"15 February 2019","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The informed consent has been signed and the study has been approved by the ethics committee of The First Affiliated Hospital of Soochow University.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"All of authors consents to make the submission.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they have no competing interests.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}},{"value":"Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Publisher\u2019s Note"}}],"article-number":"52"}}