{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,11]],"date-time":"2026-09-11T04:56:24Z","timestamp":1789102584084,"version":"build-2803163510"},"reference-count":25,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2019,11,28]],"date-time":"2019-11-28T00:00:00Z","timestamp":1574899200000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2019,11,28]],"date-time":"2019-11-28T00:00:00Z","timestamp":1574899200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Orthop Surg Res"],"published-print":{"date-parts":[[2019,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n<jats:title>Introduction<\/jats:title>\n<jats:p>Management of the subscapularis during shoulder arthroplasty is controversial. The purpose of this study was to compare the biomechanical performance of subscapularis peel (SP) and lesser tuberosity osteotomy (LTO) in a cadaveric model.<\/jats:p>\n<\/jats:sec><jats:sec>\n<jats:title>Methods<\/jats:title>\n<jats:p>The subscapularis and proximal humerus were dissected from all soft tissues in 21 fresh-frozen human cadaveric shoulders and randomized to undergo SP, LTO, or standard subscapularis tenotomy (ST, control). For SP and LTO, six #5 sutures were passed through eyelets in the implant (on lateral border and through drill holes in bicipital groove [2] and under trunion [4]). Double-row repair was performed using two lateral row transosseous sutures and four medial row sutures through the tendon (SP) or osseotendinous junction (LTO). Biomechanical properties and mode of failure were tested.<\/jats:p>\n<\/jats:sec><jats:sec>\n<jats:title>Results<\/jats:title>\n<jats:p>There were no significant differences in elongation amplitude, cyclic elongation, or maximum load to failure between the three groups (<jats:italic>P<\/jats:italic> &gt; 0.05). Mean stiffness was significantly higher in LTO (<jats:italic>P<\/jats:italic> = 0.009 vs. SP and ST). In the ST group, 7\/7 specimens failed at the tendon-suture interface. For SP, 4\/7 failed at the tendon-suture interface, one at the suture-bone interface, one fractured around the implant stem, and one at the knots. For LTO, 3\/7 failed at the tendon-suture interface, two at the suture-bone interface and two fractured around the implant stem.<\/jats:p>\n<\/jats:sec><jats:sec>\n<jats:title>Conclusions<\/jats:title>\n<jats:p>In this cadaveric model, subscapularis repair via ST, SP, and LTO techniques was biomechanically equivalent. Additional studies are needed to confirm these findings and determine the influence of biologic healing on healing rates and clinical outcomes.<\/jats:p>\n<\/jats:sec><jats:sec>\n<jats:title>Level of evidence<\/jats:title>\n<jats:p>N\/a, biomechanical laboratory study<\/jats:p>\n<\/jats:sec>","DOI":"10.1186\/s13018-019-1372-x","type":"journal-article","created":{"date-parts":[[2019,11,28]],"date-time":"2019-11-28T15:03:13Z","timestamp":1574953393000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":13,"title":["Biomechanical comparison of subscapularis peel and lesser tuberosity osteotomy for double-row subscapularis repair technique in a cadaveric arthroplasty model"],"prefix":"10.1186","volume":"14","author":[{"given":"Mandeep S.","family":"Virk","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Saleh S.","family":"Aiyash","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rachel M.","family":"Frank","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christopher S.","family":"Mellano","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Elizabeth F.","family":"Shewman","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Vincent M.","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anthony A.","family":"Romeo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2019,11,28]]},"reference":[{"issue":"3 Suppl","key":"1372_CR1","doi-asserted-by":"publisher","first-page":"S59","DOI":"10.1016\/j.jse.2006.09.002","volume":"16","author":"CS Ahmad","year":"2007","unstructured":"Ahmad CS, Wing D, Gardner TR, Levine WN, Bigliani LU. Biomechanical evaluation of subscapularis repair used during shoulder arthroplasty. J Shoulder Elbow Surg. 2007;16(3 Suppl):S59\u201364. https:\/\/doi.org\/10.1016\/j.jse.2006.09.002.","journal-title":"J Shoulder Elbow Surg."},{"key":"1372_CR2","first-page":"29","volume":"51","author":"JJ Brems","year":"2002","unstructured":"Brems JJ. Complications of shoulder arthroplasty: infections, instability, and loosening. Instr Course Lect. 2002;51:29\u201339.","journal-title":"Instr Course Lect."},{"issue":"9","key":"1372_CR3","doi-asserted-by":"publisher","first-page":"1309","DOI":"10.1016\/j.jse.2013.12.009","volume":"23","author":"Taylor Buckley","year":"2014","unstructured":"Buckley T, Miller R, Nicandri G, Lewis R, Voloshin I. Analysis of subscapularis integrity and function after lesser tuberosity osteotomy versus subscapularis tenotomy in total shoulder arthroplasty using ultrasound and validated clinical outcome measures. J Shoulder Elbow Surg. 2014;23(9):1309\u201317. https:\/\/doi.org\/10.1016\/j.jse.2013.12.009.","journal-title":"Journal of Shoulder and Elbow Surgery"},{"issue":"6","key":"1372_CR4","doi-asserted-by":"publisher","first-page":"704","DOI":"10.1016\/S0749-8063(96)90174-7","volume":"12","author":"Stephen S. Burkhart","year":"1996","unstructured":"Burkhart SS, Fischer SP, Nottage WM, Esch JC, Barber FA, Doctor D, Ferrier J. Tissue fixation security in transosseous rotator cuff repairs: a mechanical comparison of simple versus mattress sutures. The Journal of Arthroscopic & Related Surgery. 1996. https:\/\/doi.org\/10.1016\/S0749-8063(96)90174-7.","journal-title":"Arthroscopy: The Journal of Arthroscopic & Related Surgery"},{"issue":"12","key":"1372_CR5","doi-asserted-by":"publisher","first-page":"2240","DOI":"10.2106\/00004623-200212000-00018","volume":"84","author":"T. BRADLEY EDWARDS","year":"2002","unstructured":"Edwards TB, Boulahia A, Kempf JF, Boileau P, Nemoz C, Walch G. The influence of rotator cuff disease on the results of shoulder arthroplasty for primary osteoarthritis: results of a multicenter study. J Bone Joint Surg Am. 2002;84-A;(12):2240\u20138.","journal-title":"The Journal of Bone and Joint Surgery-American Volume"},{"key":"1372_CR6","doi-asserted-by":"publisher","first-page":"170","DOI":"10.2106\/JBJS.F.00407","volume":"88","author":"C Gerber","year":"2006","unstructured":"Gerber C, Pennington SD, Yian EH, Pfirrmann CA, Werner CM, Zumstein MA. Lesser tuberosity osteotomy for total shoulder arthroplasty. Surgical technique. J Bone Joint Surg Am. 2006;88 Suppl 1 Pt 2:170\u20137. https:\/\/doi.org\/10.2106\/JBJS.F.00407.","journal-title":"J Bone Joint Surg Am."},{"issue":"8","key":"1372_CR7","doi-asserted-by":"publisher","first-page":"1739","DOI":"10.2106\/JBJS.D.02788","volume":"87","author":"C Gerber","year":"2005","unstructured":"Gerber C, Yian EH, Pfirrmann CA, Zumstein MA, Werner CM. Subscapularis muscle function and structure after total shoulder replacement with lesser tuberosity osteotomy and repair. J Bone Joint Surg Am. 2005;87(8):1739\u201345. https:\/\/doi.org\/10.2106\/JBJS.D.02788.","journal-title":"J Bone Joint Surg Am."},{"issue":"8","key":"1372_CR8","doi-asserted-by":"publisher","first-page":"1087","DOI":"10.1016\/j.jse.2011.07.008","volume":"21","author":"SA Giuseffi","year":"2012","unstructured":"Giuseffi SA, Wongtriratanachai P, Omae H, Cil A, Zobitz ME, An K, et al. Biomechanical comparison of lesser tuberosity osteotomy versus subscapularis tenotomy in total shoulder arthroplasty. J Shoulder Elbow Surg. 2012;21(8):1087\u201395. https:\/\/doi.org\/10.1016\/j.jse.2011.07.008.","journal-title":"J Shoulder Elbow Surg."},{"issue":"7","key":"1372_CR9","doi-asserted-by":"publisher","first-page":"1085","DOI":"10.1016\/j.jse.2010.04.001","volume":"19","author":"JD Jackson","year":"2010","unstructured":"Jackson JD, Cil A, Smith J, Steinmann SP. Integrity and function of the subscapularis after total shoulder arthroplasty. J Shoulder Elbow Surg. 2010;19(7):1085\u201390. https:\/\/doi.org\/10.1016\/j.jse.2010.04.001.","journal-title":"J Shoulder Elbow Surg."},{"issue":"7","key":"1372_CR10","doi-asserted-by":"publisher","first-page":"1102","DOI":"10.1016\/j.jse.2011.03.019","volume":"20","author":"S Jandhyala","year":"2011","unstructured":"Jandhyala S, Unnithan A, Hughes S, Hong T. Subscapularis tenotomy versus lesser tuberosity osteotomy during total shoulder replacement: a comparison of patient outcomes. J Shoulder Elbow Surg. 2011;20(7):1102\u20137. https:\/\/doi.org\/10.1016\/j.jse.2011.03.019.","journal-title":"J Shoulder Elbow Surg."},{"issue":"24","key":"1372_CR11","doi-asserted-by":"publisher","first-page":"2239","DOI":"10.2106\/JBJS.K.01365","volume":"94","author":"PL Lapner","year":"2012","unstructured":"Lapner PL, Sabri E, Rakhra K, Bell K, Athwal GS. Comparison of lesser tuberosity osteotomy to subscapularis peel in shoulder arthroplasty: a randomized controlled trial. J Bone Joint Surg Am. 2012;94(24):2239\u201346. https:\/\/doi.org\/10.2106\/JBJS.K.01365.","journal-title":"J Bone Joint Surg Am."},{"issue":"5","key":"1372_CR12","doi-asserted-by":"publisher","first-page":"e937","DOI":"10.3928\/01477447-20160623-09","volume":"39","author":"E Lederman","year":"2016","unstructured":"Lederman E, Streit J, Idoine J, Shishani Y, Gobezie R. Biomechanical study of a subscapularis repair technique for total shoulder arthroplasty. Orthopedics. 2016;39(5):e937\u201343. https:\/\/doi.org\/10.3928\/01477447-20160623-09.","journal-title":"Orthopedics."},{"issue":"3","key":"1372_CR13","doi-asserted-by":"publisher","first-page":"407","DOI":"10.1016\/j.jse.2018.11.057","volume":"28","author":"William N. Levine","year":"2019","unstructured":"Levine WN, Munoz J, Hsu S, Byram IR, Bigliani LU, Ahmad CS, Kongmalai P, Shillingford JN. Subscapularis tenotomy versus lesser tuberosity osteotomy during total shoulder arthroplasty for primary osteoarthritis: a prospective, randomized controlled trial. Journal of Shoulder and Elbow Surgery. 2019; 28(3):407\u201314.","journal-title":"Journal of Shoulder and Elbow Surgery"},{"issue":"5","key":"1372_CR14","doi-asserted-by":"publisher","first-page":"492","DOI":"10.1016\/j.jse.2005.02.013","volume":"14","author":"BS Miller","year":"2005","unstructured":"Miller BS, Joseph TA, Noonan TJ, Horan MP, Hawkins RJ. Rupture of the subscapularis tendon after shoulder arthroplasty: diagnosis, treatment, and outcome. J Shoulder Elbow Surg. 2005;14(5):492\u20136. https:\/\/doi.org\/10.1016\/j.jse.2005.02.013.","journal-title":"J Shoulder Elbow Surg."},{"issue":"1","key":"1372_CR15","doi-asserted-by":"publisher","first-page":"29","DOI":"10.1067\/mse.2003.128195","volume":"12","author":"SL Miller","year":"2003","unstructured":"Miller SL, Hazrati Y, Klepps S, Chiang A, Flatow EL. Loss of subscapularis function after total shoulder replacement: a seldom recognized problem. J Shoulder Elbow Surg. 2003;12(1):29\u201334. https:\/\/doi.org\/10.1067\/mse.2003.128195.","journal-title":"J Shoulder Elbow Surg."},{"issue":"4","key":"1372_CR16","doi-asserted-by":"publisher","first-page":"492","DOI":"10.2106\/00004623-199304000-00003","volume":"75","author":"BH Moeckel","year":"1993","unstructured":"Moeckel BH, Altchek DW, Warren RF, Wickiewicz TL, Dines DM. Instability of the shoulder after arthroplasty. J Bone Joint Surg Am. 1993;75(4):492\u20137.","journal-title":"J Bone Joint Surg Am."},{"issue":"Suppl 2","key":"1372_CR17","doi-asserted-by":"publisher","first-page":"1","DOI":"10.2106\/JBJS.E.00441","volume":"87","author":"BA Ponce","year":"2005","unstructured":"Ponce BA, Ahluwalia RS, Mazzocca AD, Gobezie RG, Warner JJ, Millett PJ. Biomechanical and clinical evaluation of a novel lesser tuberosity repair technique in total shoulder arthroplasty. J Bone Joint Surg Am. 2005;87(Suppl 2):1\u20138. https:\/\/doi.org\/10.2106\/JBJS.E.00441.","journal-title":"J Bone Joint Surg Am."},{"issue":"1","key":"1372_CR18","doi-asserted-by":"publisher","first-page":"68","DOI":"10.1016\/j.jse.2007.04.018","volume":"17","author":"S Qureshi","year":"2008","unstructured":"Qureshi S, Hsiao A, Klug RA, Lee E, Braman J, Flatow EL. Subscapularis function after total shoulder replacement: results with lesser tuberosity osteotomy. J Shoulder Elbow Surg. 2008;17(1):68\u201372. https:\/\/doi.org\/10.1016\/j.jse.2007.04.018.","journal-title":"J Shoulder Elbow Surg."},{"key":"1372_CR19","doi-asserted-by":"publisher","DOI":"10.1177\/2471549217743605","volume":"1","author":"J Sanchez-Sotelo","year":"2017","unstructured":"Sanchez-Sotelo J. Subscapularis tenotomy in anatomic total shoulder arthroplasty. J Shoulder Elbow Surg. 2017;1:247154921774360. https:\/\/doi.org\/10.1177\/2471549217743605.","journal-title":"J Shoulder Elbow Surg"},{"issue":"7","key":"1372_CR20","doi-asserted-by":"publisher","first-page":"1627","DOI":"10.2106\/JBJS.G.01461","volume":"92","author":"JJ Scalise","year":"2010","unstructured":"Scalise JJ, Ciccone J, Iannotti JP. Clinical, radiographic, and ultrasonographic comparison of subscapularis tenotomy and lesser tuberosity osteotomy for total shoulder arthroplasty. J Bone Joint Surg Am. 2010;92(7):1627\u201334. https:\/\/doi.org\/10.2106\/JBJS.G.01461.","journal-title":"J Bone Joint Surg Am."},{"issue":"4","key":"1372_CR21","doi-asserted-by":"publisher","first-page":"671","DOI":"10.1016\/j.jse.2007.11.005","volume":"17","author":"M Scheibel","year":"2008","unstructured":"Scheibel M, Habermeyer P. Subscapularis dysfunction following anterior surgical approaches to the shoulder. J Shoulder Elbow Surg. 2008;17(4):671\u201383. https:\/\/doi.org\/10.1016\/j.jse.2007.11.005.","journal-title":"J Shoulder Elbow Surg."},{"issue":"11","key":"1372_CR22","doi-asserted-by":"publisher","first-page":"1057","DOI":"10.2106\/JBJS.J.00160","volume":"93","author":"JJ Schreiber","year":"2011","unstructured":"Schreiber JJ, Anderson PA, Rosas HG, Buchholz AL, Au AG. Hounsfield units for assessing bone mineral density and strength: a tool for osteoporosis management. J Bone Joint Surg Am. 2011;93(11):1057\u201363. https:\/\/doi.org\/10.2106\/JBJS.J.00160.","journal-title":"J Bone Joint Surg Am."},{"issue":"4","key":"1372_CR23","doi-asserted-by":"publisher","first-page":"315","DOI":"10.1067\/mse.2002.124426","volume":"11","author":"JW Sperling","year":"2002","unstructured":"Sperling JW, Potter HG, Craig EV, Flatow E, Warren RF. Magnetic resonance imaging of painful shoulder arthroplasty. J Shoulder Elbow Surg. 2002;11(4):315\u201321. https:\/\/doi.org\/10.1067\/mse.2002.124426.","journal-title":"J Shoulder Elbow Surg."},{"issue":"1","key":"1372_CR24","doi-asserted-by":"publisher","first-page":"156","DOI":"10.1016\/j.jse.2007.04.016","volume":"17","author":"GR Van den Berghe","year":"2008","unstructured":"Van den Berghe GR, Nguyen B, Patil S, D\u2019Lima DD, Mahar A, Pedowitz R, et al. A biomechanical evaluation of three surgical techniques for subscapularis repair. J Shoulder Elbow Surg. 2008;17(1):156\u201361. https:\/\/doi.org\/10.1016\/j.jse.2007.04.016.","journal-title":"J Shoulder Elbow Surg."},{"issue":"5","key":"1372_CR25","doi-asserted-by":"publisher","first-page":"657","DOI":"10.1016\/j.jse.2010.01.014","volume":"19","author":"GS Van Thiel","year":"2010","unstructured":"Van Thiel GS, Wang VM, Wang FC, Nho SJ, Piasacki DP, Bach BR, et al. Biomechanical similarities among subscapularis repairs after shoulder arthroplasty. J Shoulder Elbow Surg. 2010;19(5):657\u201363. https:\/\/doi.org\/10.1016\/j.jse.2010.01.014.","journal-title":"J Shoulder Elbow Surg."}],"container-title":["Journal of Orthopaedic Surgery and Research"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s13018-019-1372-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1186\/s13018-019-1372-x\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s13018-019-1372-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,11,27]],"date-time":"2020-11-27T00:33:30Z","timestamp":1606437210000},"score":1,"resource":{"primary":{"URL":"https:\/\/josr-online.biomedcentral.com\/articles\/10.1186\/s13018-019-1372-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,11,28]]},"references-count":25,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2019,12]]}},"alternative-id":["1372"],"URL":"https:\/\/doi.org\/10.1186\/s13018-019-1372-x","relation":{},"ISSN":["1749-799X"],"issn-type":[{"value":"1749-799X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,11,28]]},"assertion":[{"value":"10 July 2019","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"11 September 2019","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"28 November 2019","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"This research was reviewed and approved by the IRB at RUSH University Medical Center.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"Anthony A. Romeo receives research support and is a consultant for Arthrex Inc. Mandeep S. Virk is a consultant for Exactech Inc.\u00a0All other authors declare that they have no competing interests. No financial benefits were received for the production of this study.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"391"}}