{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,28]],"date-time":"2026-10-28T14:23:26Z","timestamp":1793197406590,"version":"4.5.0"},"reference-count":38,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2019,12,1]],"date-time":"2019-12-01T00:00:00Z","timestamp":1575158400000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2019,12,27]],"date-time":"2019-12-27T00:00:00Z","timestamp":1577404800000},"content-version":"vor","delay-in-days":26,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/100007308","name":"Arthrex GmbH","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100007308","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Orthop Surg Res"],"published-print":{"date-parts":[[2019,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec><jats:title>Background<\/jats:title><jats:p>While open wedge high tibial osteotomy (owHTO) is an established standard procedure to treat medial osteoarthritis of the knee in combination with varus deformity, it bears the risk of postoperative hardware failures and lateral cortical hinge fractures. This in turn can lead to an accelerated osteoarthritis, non-union, or a loss of correction accuracy. The purpose of the study was to evaluate the radiologic outcomes of owHTO with a carbon fiber reinforced poly-ether-ether-ketone (CF-PEEK) plate fixation in patients with medial osteoarthritis and varus deformity.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>Three hundred twenty-four consecutive patients (346 knees) who were treated with owHTO using the PEEKPower HTO plate were included in this retrospective study; 89.9% of the patients were overweight or obese. Patients were followed by conventional radiographs over a 12-month period. Typical plate-related results such as the time and quality of gap healing as well as the correction accuracy were analyzed. Furthermore, the number of lateral cortex fractures was determined.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>Bony consolidation was observed after a mean gap healing time of 4.0\u2009\u00b1\u20091.7\u2009months independent on the patients\u2019 weight (<jats:italic>p<\/jats:italic>\u2009=\u20090.2302). With increasing gap sizes, bony healing was significantly prolonged (<jats:italic>p<\/jats:italic>\u2009&lt;\u20090.001). Additionally, patients with greater gap sizes had a significantly increased risk for a lateral cortex fracture (<jats:italic>p<\/jats:italic>\u2009=\u20090.0041). However, none of the patients had a non-union 1\u2009year postoperative. A hinge fracture occurred in 30% of patients. Hinge fractures with Takeuchi grades I and II increased the gap healing time compared to no fracture (<jats:italic>p<\/jats:italic>\u2009=\u20090.0069 and<jats:italic>p<\/jats:italic>\u2009=\u20090.0002, respectively), but only 1.2% of patients with hinge fracture had a clinical relevant loss of correction\u2009\u2265\u20093\u2009mm. No implant failures were found.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusions<\/jats:title><jats:p>Open wedge HTO using the PEEKPower HTO plate for patients with medial osteoarthritis of the knee in combination with tibial varus deformity leads to excellent bony consolidation also in cases with a hinge fracture, a gap size\u2009&gt;\u200912\u2009mm as well as for severely obese patients.<\/jats:p><\/jats:sec>","DOI":"10.1186\/s13018-019-1514-1","type":"journal-article","created":{"date-parts":[[2019,12,27]],"date-time":"2019-12-27T18:02:42Z","timestamp":1577469762000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":11,"title":["Plate-related results of opening wedge high tibial osteotomy with a carbon fiber reinforced poly-ether-ether-ketone (CF-PEEK) plate fixation: a retrospective case series of 346 knees"],"prefix":"10.1186","volume":"14","author":[{"given":"Claudia","family":"Hartz","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ralph","family":"Wischatta","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Eckhardt","family":"Klostermeier","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Malte","family":"Paetzold","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Klaus","family":"Gerlach","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Frank","family":"Pries","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2019,12,27]]},"reference":[{"issue":"1","key":"1514_CR1","first-page":"21","volume":"16","author":"P Aglietti","year":"2003","unstructured":"Aglietti P, Buzzi R, Vena LM, Baldini A, Mondaini A. High tibial valgus osteotomy for medial gonarthrosis: a 10- to 21-year study. J Knee Surg. 2003;16(1):21\u20136.","journal-title":"J Knee Surg"},{"issue":"6","key":"1514_CR2","doi-asserted-by":"publisher","first-page":"1063","DOI":"10.1016\/j.arthro.2013.02.020","volume":"29","author":"WH Jung","year":"2013","unstructured":"Jung WH, Chun CW, Lee JH, Ha JH, Kim JH, Jeong JH. Comparative study of medial opening-wedge high tibial osteotomy using 2 different implants. Arthroscopy. 2013;29(6):1063\u201371.","journal-title":"Arthroscopy"},{"issue":"3","key":"1514_CR3","doi-asserted-by":"publisher","first-page":"469","DOI":"10.2106\/00004623-200303000-00011","volume":"85-a","author":"TR Sprenger","year":"2003","unstructured":"Sprenger TR, Doerzbacher JF. Tibial osteotomy for the treatment of varus gonarthrosis. Survival and failure analysis to twenty-two years. J Bone Joint Surg Am. 2003;85-a(3):469\u201374.","journal-title":"J Bone Joint Surg Am"},{"issue":"11","key":"1514_CR4","doi-asserted-by":"publisher","first-page":"1454","DOI":"10.1302\/0301-620X.88B11.17743","volume":"88","author":"RW Brouwer","year":"2006","unstructured":"Brouwer RW, Bierma-Zeinstra SM, van Raaij TM, Verhaar JA. Osteotomy for medial compartment arthritis of the knee using a closing wedge or an opening wedge controlled by a Puddu plate. A one-year randomised, controlled study. J Bone Joint Surg Br. 2006;88(11):1454\u20139.","journal-title":"J Bone Joint Surg Br"},{"issue":"10","key":"1514_CR5","doi-asserted-by":"publisher","first-page":"649","DOI":"10.1007\/s00402-003-0588-7","volume":"124","author":"G Spahn","year":"2004","unstructured":"Spahn G. Complications in high tibial (medial opening wedge) osteotomy. Arch Orthop Trauma Surg. 2004;124(10):649\u201353.","journal-title":"Arch Orthop Trauma Surg"},{"issue":"1","key":"1514_CR6","doi-asserted-by":"publisher","first-page":"68","DOI":"10.1055\/s-0030-1247797","volume":"21","author":"MP van den Bekerom","year":"2008","unstructured":"van den Bekerom MP, Patt TW, Kleinhout MY, van der Vis HM, Albers GH. Early complications after high tibial osteotomy: a comparison of two techniques. J Knee Surg. 2008;21(1):68\u201374.","journal-title":"J Knee Surg"},{"issue":"2","key":"1514_CR7","doi-asserted-by":"publisher","first-page":"254","DOI":"10.1016\/j.arthro.2014.08.028","volume":"31","author":"S Schr\u00f6ter","year":"2015","unstructured":"Schr\u00f6ter S, Freude T, Kopp MM, Konstantinidis L, Dobele S, Stockle U, et al. Smoking and unstable hinge fractures cause delayed gap filling irrespective of early weight bearing after open wedge osteotomy. Arthroscopy. 2015;31(2):254\u201365.","journal-title":"Arthroscopy"},{"issue":"1","key":"1514_CR8","doi-asserted-by":"publisher","first-page":"85","DOI":"10.1016\/j.arthro.2011.06.034","volume":"28","author":"R Takeuchi","year":"2012","unstructured":"Takeuchi R, Ishikawa H, Kumagai K, Yamaguchi Y, Chiba N, Akamatsu Y, et al. Fractures around the lateral cortical hinge after a medial opening-wedge high tibial osteotomy: a new classification of lateral hinge fracture. Arthroscopy. 2012;28(1):85\u201394.","journal-title":"Arthroscopy"},{"issue":"5","key":"1514_CR9","doi-asserted-by":"publisher","first-page":"1118","DOI":"10.1177\/0363546514525929","volume":"42","author":"R Martin","year":"2014","unstructured":"Martin R, Birmingham TB, Willits K, Litchfield R, Lebel ME, Giffin JR. Adverse event rates and classifications in medial opening wedge high tibial osteotomy. Am J Sports Med. 2014;42(5):1118\u201326.","journal-title":"Am J Sports Med"},{"issue":"2","key":"1514_CR10","doi-asserted-by":"publisher","first-page":"217","DOI":"10.1007\/s00264-009-0723-3","volume":"34","author":"EM Nelissen","year":"2010","unstructured":"Nelissen EM, van Langelaan EJ, Nelissen RG. Stability of medial opening wedge high tibial osteotomy: a failure analysis. Int Orthop. 2010;34(2):217\u201323.","journal-title":"Int Orthop"},{"issue":"1","key":"1514_CR11","doi-asserted-by":"publisher","first-page":"34","DOI":"10.1007\/s00167-003-0485-1","volume":"13","author":"SJ Warden","year":"2005","unstructured":"Warden SJ, Morris HG, Crossley KM, Brukner PD, Bennell KL. Delayed- and non-union following opening wedge high tibial osteotomy: surgeons\u2019 results from 182 completed cases. Knee Surg Sports Traumatol Arthrosc. 2005;13(1):34\u20137.","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"issue":"4","key":"1514_CR12","first-page":"464","volume":"16","author":"HT Nawas","year":"2016","unstructured":"Nawas HT, Vansadia DV, Heltsley JR, Suri M, Montgomery S, Jones DG. Factors affecting the union of opening wedge high tibial osteotomy using a titanium wedge plate. Ochsner J. 2016;16(4):464\u201370.","journal-title":"Ochsner J"},{"issue":"3","key":"1514_CR13","doi-asserted-by":"publisher","first-page":"291","DOI":"10.1007\/s00167-005-0690-1","volume":"14","author":"JD Agneskirchner","year":"2006","unstructured":"Agneskirchner JD, Freiling D, Hurschler C, Lobenhoffer P. Primary stability of four different implants for opening wedge high tibial osteotomy. Knee Surg Sports Traumatol Arthrosc. 2006;14(3):291\u2013300.","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"issue":"3","key":"1514_CR14","doi-asserted-by":"publisher","first-page":"272","DOI":"10.1016\/j.clinbiomech.2005.10.010","volume":"21","author":"G Spahn","year":"2006","unstructured":"Spahn G, Muckley T, Kahl E, Hofmann GO. Biomechanical investigation of different internal fixations in medial opening-wedge high tibial osteotomy. Clin Biomech (Bristol, Avon). 2006;21(3):272\u20138.","journal-title":"Clin Biomech (Bristol, Avon)"},{"issue":"2","key":"1514_CR15","doi-asserted-by":"publisher","first-page":"153","DOI":"10.1007\/s00132-003-0593-0","volume":"33","author":"P Lobenhoffer","year":"2004","unstructured":"Lobenhoffer P, Agneskirchner J, Zoch W. Open valgus alignment osteotomy of the proximal tibia with fixation by medial plate fixator. Orthopade. 2004;33(2):153\u201360.","journal-title":"Orthopade"},{"issue":"Suppl 2","key":"1514_CR16","doi-asserted-by":"publisher","first-page":"B55","DOI":"10.1016\/j.injury.2003.09.025","volume":"34","author":"AE Staubli","year":"2003","unstructured":"Staubli AE, De Simoni C, Babst R, Lobenhoffer P. TomoFix: a new LCP-concept for open wedge osteotomy of the medial proximal tibia\u2013early results in 92 cases. Injury. 2003;34(Suppl 2):B55\u201362.","journal-title":"Injury"},{"issue":"Suppl 1","key":"1514_CR17","doi-asserted-by":"publisher","first-page":"S29","DOI":"10.1097\/BOT.0b013e3182070cda","volume":"25","author":"J Doornink","year":"2011","unstructured":"Doornink J, Fitzpatrick DC, Madey SM, Bottlang M. Far cortical locking enables flexible fixation with periarticular locking plates. J Orthop Trauma. 2011;25(Suppl 1):S29\u201334.","journal-title":"J Orthop Trauma"},{"issue":"10","key":"1514_CR18","doi-asserted-by":"publisher","first-page":"1648","DOI":"10.1016\/j.injury.2014.04.018","volume":"45","author":"G Roderer","year":"2014","unstructured":"Roderer G, Gebhard F, Duerselen L, Ignatius A, Claes L. Delayed bone healing following high tibial osteotomy related to increased implant stiffness in locked plating. Injury. 2014;45(10):1648\u201352.","journal-title":"Injury"},{"key":"1514_CR19","unstructured":"PEEKPower High tibial osteotomy plate \u2013 white paper LA2-0118-EN_A [Internet]. 2013 [cited 2019 Feb 07]. Available from https:\/\/d1psc3qesfsa61.cloudfront.net\/pdfs\/cnCqQ7xBN02lzwE8SjFidA\/cnCqQ7xBN02lzwE8SjFidA.pdf?Expires=1549526558&Signature=aFK8z4e1wCh6uHjlECMRB2FZU5eUGQelq31cSedi8UvsijIFr-E-bJ923KOMg8Dtcbfz4vhyX8FBLnIxipCjGm8fRkX-597SRko5U065hZY1Vwj5Rhtqlmcc5wc48EPIdd-fkv7YML2R81XVCLTOXp6gw-xTKp5jgEDj6NHIhnBXqNAFI5UgL8El~DySDaijEHvooanBZYeWQarqHTePUAJbGzi3LnjJwVWhlXNi7hzTGzn5I7zt412L2gbnL6HN90hf~dwCjMjCB1kQkN1UiZgorb-qkLn1Zfy~Rkwb5Je5fUkJPHlWzjIs2lnhuJbwEVPl2BoA0FdBN~hQ7jKWkA__&Key-Pair-Id=APKAJMGJRW6JX5OBM5LA."},{"issue":"7","key":"1514_CR20","doi-asserted-by":"publisher","first-page":"2032","DOI":"10.1007\/s00167-014-2914-8","volume":"23","author":"M Cotic","year":"2015","unstructured":"Cotic M, Vogt S, Hinterwimmer S, Feucht MJ, Slotta-Huspenina J, Schuster T, et al. A matched-pair comparison of two different locking plates for valgus-producing medial open-wedge high tibial osteotomy: peek-carbon composite plate versus titanium plate. Knee Surg Sports Traumatol Arthrosc. 2015;23(7):2032\u201340.","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"issue":"12","key":"1514_CR21","doi-asserted-by":"publisher","first-page":"3707","DOI":"10.1007\/s00167-014-3287-8","volume":"23","author":"M Cotic","year":"2015","unstructured":"Cotic M, Vogt S, Feucht MJ, Saier T, Minzlaff P, Hinterwimmer S, et al. Prospective evaluation of a new plate fixator for valgus-producing medial open-wedge high tibial osteotomy. Knee Surg Sports Traumatol Arthrosc. 2015;23(12):3707\u201316.","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"issue":"3","key":"1514_CR22","doi-asserted-by":"publisher","first-page":"132","DOI":"10.1007\/s00167-002-0334-7","volume":"11","author":"P Lobenhoffer","year":"2003","unstructured":"Lobenhoffer P, Agneskirchner JD. Improvements in surgical technique of valgus high tibial osteotomy. Knee Surg Sports Traumatol Arthrosc. 2003;11(3):132\u20138.","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"issue":"2","key":"1514_CR23","doi-asserted-by":"publisher","first-page":"93","DOI":"10.1097\/00132588-200212000-00004","volume":"1","author":"P Lobenhoffer","year":"2002","unstructured":"Lobenhoffer P, De Simoni C, Staubli AE. Open-wedge high tibial osteotomy with rigid plate fixation. Tech Knee Surg. 2002;1(2):93\u2013105.","journal-title":"Tech Knee Surg"},{"issue":"2","key":"1514_CR24","doi-asserted-by":"publisher","first-page":"185","DOI":"10.1007\/s00132-003-0597-9","volume":"33","author":"V Franco","year":"2004","unstructured":"Franco V, Cipolla M, Gerullo G, Gianni E, Puddu G. Open wedge osteotomy of the distal femur in the valgus knee. Orthopade. 2004;33(2):185\u201392.","journal-title":"Orthopade"},{"key":"1514_CR25","doi-asserted-by":"crossref","first-page":"250","DOI":"10.1097\/00003086-198909000-00035","volume":"246","author":"A Miniaci","year":"1989","unstructured":"Miniaci A, Ballmer FT, Ballmer PM, Jakob RP. Proximal tibial osteotomy. A new fixation device. Clin Orthop Relat Res. 1989;246:250\u20139.","journal-title":"Clin Orthop Relat Res"},{"issue":"7","key":"1514_CR26","doi-asserted-by":"publisher","first-page":"705","DOI":"10.1016\/j.otsr.2011.06.011","volume":"97","author":"T Brosset","year":"2011","unstructured":"Brosset T, Pasquier G, Migaud H, Gougeon F. Opening wedge high tibial osteotomy performed without filling the defect but with locking plate fixation (TomoFix) and early weight-bearing: prospective evaluation of bone union, precision and maintenance of correction in 51 cases. Orthop Traumatol Surg Res OTSR. 2011;97(7):705\u201311.","journal-title":"Orthop Traumatol Surg Res OTSR"},{"key":"1514_CR27","doi-asserted-by":"crossref","unstructured":"Solomon L, Warwick DJ, Nayagam S. Apley and Solomon\u2019s concise system of orthopaedics and trauma. 4th ed: CRC Press; 2014.","DOI":"10.1201\/9780429166808"},{"issue":"1","key":"1514_CR28","doi-asserted-by":"publisher","first-page":"55","DOI":"10.1007\/s00264-013-2082-3","volume":"38","author":"S Floerkemeier","year":"2014","unstructured":"Floerkemeier S, Staubli AE, Schroeter S, Goldhahn S, Lobenhoffer P. Does obesity and nicotine abuse influence the outcome and complication rate after open-wedge high tibial osteotomy? A retrospective evaluation of five hundred and thirty three patients. Int Orthop. 2014;38(1):55\u201360.","journal-title":"Int Orthop"},{"key":"1514_CR29","doi-asserted-by":"publisher","first-page":"123","DOI":"10.1186\/s40064-016-1745-0","volume":"5","author":"M Yokoyama","year":"2016","unstructured":"Yokoyama M, Nakamura Y, Onishi T, Hirano K, Doi M. Healing period after open high tibial osteotomy and related factors: can we really say that it is long? SpringerPlus. 2016;5:123.","journal-title":"SpringerPlus"},{"issue":"6","key":"1514_CR30","doi-asserted-by":"publisher","first-page":"493","DOI":"10.1007\/s007760100003","volume":"6","author":"HR Choi","year":"2001","unstructured":"Choi HR, Hasegawa Y, Kondo S, Shimizu T, Ida K, Iwata H. High tibial osteotomy for varus gonarthrosis: a 10- to 24-year follow-up study. J Orthop Sci. 2001;6(6):493\u20137.","journal-title":"J Orthop Sci"},{"issue":"2","key":"1514_CR31","doi-asserted-by":"publisher","first-page":"103","DOI":"10.1016\/S0968-0160(00)00061-2","volume":"8","author":"P Hernigou","year":"2001","unstructured":"Hernigou P, Ma W. Open wedge tibial osteotomy with acrylic bone cement as bone substitute. Knee. 2001;8(2):103\u201310.","journal-title":"Knee"},{"issue":"1","key":"1514_CR32","doi-asserted-by":"publisher","first-page":"64","DOI":"10.1177\/0363546510377445","volume":"39","author":"C Hui","year":"2011","unstructured":"Hui C, Salmon LJ, Kok A, Williams HA, Hockers N, van der Tempel WM, et al. Long-term survival of high tibial osteotomy for medial compartment osteoarthritis of the knee. Am J Sports Med. 2011;39(1):64\u201370.","journal-title":"Am J Sports Med"},{"issue":"33","key":"1514_CR33","doi-asserted-by":"publisher","first-page":"6713","DOI":"10.1016\/j.biomaterials.2005.04.056","volume":"26","author":"RD Gaasbeek","year":"2005","unstructured":"Gaasbeek RD, Toonen HG, van Heerwaarden RJ, Buma P. Mechanism of bone incorporation of beta-TCP bone substitute in open wedge tibial osteotomy in patients. Biomaterials. 2005;26(33):6713\u20139.","journal-title":"Biomaterials"},{"issue":"6","key":"1514_CR34","doi-asserted-by":"publisher","first-page":"451","DOI":"10.1016\/j.knee.2004.08.004","volume":"11","author":"WL van Hemert","year":"2004","unstructured":"van Hemert WL, Willems K, Anderson PG, van Heerwaarden RJ, Wymenga AB. Tricalcium phosphate granules or rigid wedge preforms in open wedge high tibial osteotomy: a radiological study with a new evaluation system. Knee. 2004;11(6):451\u20136.","journal-title":"Knee"},{"issue":"2","key":"1514_CR35","doi-asserted-by":"publisher","first-page":"613","DOI":"10.1007\/s11999-010-1508-0","volume":"469","author":"G Kumar","year":"2011","unstructured":"Kumar G, Dunlop C. Case report: a technique to remove a jammed locking screw from a locking plate. Clin Orthop Relat Res. 2011;469(2):613\u20136.","journal-title":"Clin Orthop Relat Res"},{"issue":"3","key":"1514_CR36","doi-asserted-by":"publisher","first-page":"333","DOI":"10.1007\/s00167-010-1335-6","volume":"19","author":"G Meidinger","year":"2011","unstructured":"Meidinger G, Imhoff AB, Paul J, Kirchhoff C, Sauerschnig M, Hinterwimmer S. May smokers and overweight patients be treated with a medial open-wedge HTO? Risk factors for non-union. Knee Surg Sports Traumatol Arthrosc. 2011;19(3):333\u20139.","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"issue":"5","key":"1514_CR37","doi-asserted-by":"publisher","first-page":"819","DOI":"10.1007\/s00264-013-1817-5","volume":"37","author":"N Maffulli","year":"2013","unstructured":"Maffulli N, Loppini M, Longo UG, Denaro V, Oliva F. Bovine xenograft locking Puddu plate versus tricalcium phosphate spacer non-locking Puddu plate in opening-wedge high tibial osteotomy: a prospective double-cohort study. Int Orthop. 2013;37(5):819\u201326.","journal-title":"Int Orthop"},{"issue":"9","key":"1514_CR38","doi-asserted-by":"publisher","first-page":"944","DOI":"10.1016\/j.clinbiomech.2004.06.007","volume":"19","author":"K Stoffel","year":"2004","unstructured":"Stoffel K, Stachowiak G, Kuster M. Open wedge high tibial osteotomy: biomechanical investigation of the modified Arthrex Osteotomy Plate (Puddu Plate) and the TomoFix Plate. Clin Biomech (Bristol, Avon). 2004;19(9):944\u201350.","journal-title":"Clin Biomech (Bristol, Avon)"}],"container-title":["Journal of Orthopaedic Surgery and Research"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s13018-019-1514-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1186\/s13018-019-1514-1\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s13018-019-1514-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,10,9]],"date-time":"2022-10-09T12:35:22Z","timestamp":1665318922000},"score":1,"resource":{"primary":{"URL":"https:\/\/josr-online.biomedcentral.com\/articles\/10.1186\/s13018-019-1514-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,12]]},"references-count":38,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2019,12]]}},"alternative-id":["1514"],"URL":"https:\/\/doi.org\/10.1186\/s13018-019-1514-1","relation":{},"ISSN":["1749-799X"],"issn-type":[{"value":"1749-799X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,12]]},"assertion":[{"value":"27 September 2019","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"11 December 2019","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"27 December 2019","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The ethics committee of the University of L\u00fcbeck approved this study.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they have no competing interests.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"466"}}