{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,23]],"date-time":"2026-03-23T12:55:29Z","timestamp":1774270529929,"version":"3.50.1"},"reference-count":37,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2020,4,20]],"date-time":"2020-04-20T00:00:00Z","timestamp":1587340800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2020,4,20]],"date-time":"2020-04-20T00:00:00Z","timestamp":1587340800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Orthop Surg Res"],"published-print":{"date-parts":[[2020,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n<jats:title>Background<\/jats:title>\n<jats:p>Adult forearm fractures require surgical treatment in most cases. Open reduction and internal fixation with plate osteosynthesis is the therapy of choice. Intramedullary fixation offers several advantages compared to plate fixation but is not routinely used. The aim of our study was to compare a newly designed ulna nail with angular stable plating in a biomechanical testing setup of an ulna shaft fracture with a diaphyseal defect.<\/jats:p>\n<\/jats:sec><jats:sec>\n<jats:title>Methods<\/jats:title>\n<jats:p>Ten pairs of sawbones with a defect osteotomy of the ulna shaft (OTA 2U2C3) were fixed with an interlocked nail or locked plate osteosynthesis. The constructs were tested under four-point bending, torsional loading and axial loading in a servo-pneumatic testing machine to compare the stiffness of both stabilization methods.<\/jats:p>\n<\/jats:sec><jats:sec>\n<jats:title>Results<\/jats:title>\n<jats:p>The nail constructs show lower yet sufficient bending stiffness (62.25 \u00b1 6.64\u2009N\/mm) compared to the plate constructs (71.2 \u00b1 5.98\u2009N\/mm, <jats:italic>p<\/jats:italic> = 0.005). The torsional loading test shows superior stiffness of the plate constructs (0.24 \u00b1 0.03\u2009Nm\/deg vs. 0.1 \u00b1 0.01\u2009Nm\/deg; <jats:italic>p<\/jats:italic> &lt; 0.001), while the axial loading shows superior stiffness of the nail constructs (1028.9 \u00b1 402.1\u2009N\/mm vs. 343.9 \u00b1 112.6\u2009N\/mm; <jats:italic>p<\/jats:italic> &lt; 0.001).<\/jats:p>\n<\/jats:sec><jats:sec>\n<jats:title>Conclusions<\/jats:title>\n<jats:p>Intramedullary nailing of ulna shaft fractures obtains sufficient but lower stability in bending and torsional loading when compared to rigid angular stable plating and could be an alternative technique to plate fixation. The lower stability and the closed stabilization technique allow for a rapid periosteal healing, which is not present in stiffer constructs.<\/jats:p>\n<\/jats:sec>","DOI":"10.1186\/s13018-020-01656-z","type":"journal-article","created":{"date-parts":[[2020,4,20]],"date-time":"2020-04-20T10:02:55Z","timestamp":1587376975000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":8,"title":["Nailing of diaphyseal ulna fractures in adults\u2014biomechanical evaluation of a novel implant in comparison with locked plating"],"prefix":"10.1186","volume":"15","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-9281-3428","authenticated-orcid":false,"given":"Johannes Christof","family":"Hopf","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dorothea","family":"Mehler","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tobias Eckhard","family":"Nowak","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dominik","family":"Gruszka","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Daniel","family":"Wagner","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Pol Maria","family":"Rommens","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2020,4,20]]},"reference":[{"key":"1656_CR1","doi-asserted-by":"publisher","first-page":"437","DOI":"10.5435\/JAAOS-22-07-437","volume":"22","author":"LM Schulte","year":"2014","unstructured":"Schulte LM, Meals CG, Neviaser RJ. Management of adult diaphyseal both-bone forearm fractures. J Am Acad Orthop Surg. 2014;22:437\u201346.","journal-title":"J Am Acad Orthop Surg."},{"key":"1656_CR2","doi-asserted-by":"publisher","first-page":"335","DOI":"10.1016\/j.jhsa.2013.06.020","volume":"39","author":"J Barton\u00ed\u010dek","year":"2014","unstructured":"Barton\u00ed\u010dek J, Koz\u00e1nek M, Jupiter JB. History of operative treatment of forearm diaphyseal fractures. J Hand Surg Am. 2014;39:335\u201342.","journal-title":"J Hand Surg Am."},{"key":"1656_CR3","doi-asserted-by":"publisher","first-page":"287","DOI":"10.2106\/00004623-197557030-00001","volume":"57","author":"LD Anderson","year":"1975","unstructured":"Anderson LD, Sisk D, Tooms RE, Park WI. Compression-plate fixation in acute diaphyseal fractures of the radius and ulna. J Bone Joint Surg Am. 1975;57:287\u201397.","journal-title":"J Bone Joint Surg Am."},{"key":"1656_CR4","doi-asserted-by":"publisher","first-page":"239","DOI":"10.1007\/s00113-018-0461-3","volume":"121","author":"C Hierholzer","year":"2018","unstructured":"Hierholzer C, Friederichs J, Augat P, Woltmann A, Trapp O, B\u00fchren V, et al. Evolution and principles of intramedullary locked nailing. Unfallchirurg. 2018;121:239\u201355.","journal-title":"Unfallchirurg."},{"key":"1656_CR5","doi-asserted-by":"publisher","first-page":"1356","DOI":"10.3928\/0147-7447-19851101-08","volume":"8","author":"RF Kyle","year":"1985","unstructured":"Kyle RF. Biomechanics of intramedullary fracture fixation. Orthopedics. 1985;8:1356\u20139.","journal-title":"Orthopedics."},{"key":"1656_CR6","first-page":"803","volume":"31","author":"H-Y He","year":"2018","unstructured":"He H-Y, Zhang J-Z, Wang X-W, Liu Z. Acumed intramedullary nail for the treatment of adult diaphyseal both-bone forearm fractures. Zhongguo Gu Shang. 2018;31:803\u20137.","journal-title":"Zhongguo Gu Shang."},{"key":"1656_CR7","doi-asserted-by":"publisher","first-page":"1216","DOI":"10.1016\/j.jhsa.2011.03.020","volume":"36","author":"DB Jones","year":"2011","unstructured":"Jones DB, Kakar S. Adult diaphyseal forearm fractures: intramedullary nail versus plate fixation. J Hand Surg Am. 2011;36:1216\u20139.","journal-title":"J Hand Surg Am."},{"key":"1656_CR8","doi-asserted-by":"publisher","first-page":"769","DOI":"10.1007\/s00590-013-1242-x","volume":"24","author":"SK Lee","year":"2014","unstructured":"Lee SK, Kim KJ, Lee JW, Choy WS. Plate osteosynthesis versus intramedullary nailing for both forearm bones fractures. Eur J Orthop Surg Traumatol. 2014;24:769\u201376.","journal-title":"Eur J Orthop Surg Traumatol."},{"key":"1656_CR9","doi-asserted-by":"publisher","first-page":"722","DOI":"10.1007\/s00268-016-3753-1","volume":"41","author":"L Zhao","year":"2017","unstructured":"Zhao L, Wang B, Bai X, Liu Z, Gao H, Li Y. Plate fixation versus intramedullary nailing for both-bone forearm fractures: a meta-analysis of randomized controlled trials and cohort studies. World J Surg. 2017;41:722\u201333.","journal-title":"World J Surg."},{"key":"1656_CR10","doi-asserted-by":"publisher","first-page":"611","DOI":"10.1097\/BOT.0b013e31824aee8e","volume":"26","author":"NMK Behnke","year":"2012","unstructured":"Behnke NMK, Redjal HR, Nguyen VT, Zinar DM. Internal fixation of diaphyseal fractures of the forearm: a retrospective comparison of hybrid fixation versus dual plating. J Orthop Trauma. 2012;26:611\u20136.","journal-title":"J Orthop Trauma."},{"key":"1656_CR11","doi-asserted-by":"publisher","first-page":"319","DOI":"10.1016\/j.otsr.2015.11.019","volume":"102","author":"XF Zhang","year":"2016","unstructured":"Zhang XF, Huang JW, Mao HX, Chen WB, Luo Y. Adult diaphyseal both-bone forearm fractures: a clinical and biomechanical comparison of four different fixations. Orthop Traumatol Surg Res. 2016;102:319\u201325.","journal-title":"Orthop Traumatol Surg Res."},{"key":"1656_CR12","doi-asserted-by":"publisher","first-page":"1093","DOI":"10.1302\/0301-620X.84B8.0841093","volume":"84","author":"SM Perren","year":"2002","unstructured":"Perren SM. Evolution of the internal fixation of long bone fractures. The scientific basis of biological internal fixation: choosing a new balance between stability and biology. J Bone Joint Surg Br. 2002;84:1093\u2013110.","journal-title":"J Bone Joint Surg Br."},{"key":"1656_CR13","first-page":"19","volume":"42","author":"AF Tencer","year":"1993","unstructured":"Tencer AF, Johnson KD, Kyle RF, Fu FH. Biomechanics of fractures and fracture fixation. Instr Course Lect. 1993;42:19\u201355.","journal-title":"Instr Course Lect."},{"key":"1656_CR14","doi-asserted-by":"crossref","unstructured":"Matter P. History of the AO and its global effect on operative fracture treatment. Clin Orthop Relat Res. 1998:11\u20138.","DOI":"10.1097\/00003086-199802000-00003"},{"issue":"Suppl 1","key":"1656_CR15","doi-asserted-by":"publisher","first-page":"S12","DOI":"10.1016\/S0020-1383(18)30296-1","volume":"49","author":"AR MacLeod","year":"2018","unstructured":"MacLeod AR, Pankaj P. Pre-operative planning for fracture fixation using locking plates: device configuration and other considerations. Injury. 2018;49(Suppl 1):S12\u20138.","journal-title":"Injury."},{"key":"1656_CR16","doi-asserted-by":"publisher","first-page":"1135","DOI":"10.1016\/j.injury.2014.04.020","volume":"45","author":"A Patel","year":"2014","unstructured":"Patel A, Li L, Anand A. Systematic review: functional outcomes and complications of intramedullary nailing versus plate fixation for both-bone diaphyseal forearm fractures in children. Injury. 2014;45:1135\u201343.","journal-title":"Injury."},{"key":"1656_CR17","doi-asserted-by":"publisher","first-page":"164","DOI":"10.1097\/BPB.0000000000000703","volume":"29","author":"\u00c7 \u00d6zcan","year":"2020","unstructured":"\u00d6zcan \u00c7, Taylan \u00d6z T, T\u00fcrkmen \u0130. Radius and ulna locking intramedullary nails are safe and reliable after adolescent forearm fractures: a case-controlled study in adolescents. J Pediatr Orthop B. 2020;29:164\u201371.","journal-title":"J Pediatr Orthop B."},{"key":"1656_CR18","doi-asserted-by":"publisher","first-page":"2053","DOI":"10.1016\/j.injury.2018.08.023","volume":"49","author":"KP Freese","year":"2018","unstructured":"Freese KP, Faulk LW, Palmer C, Baschal RM, Sibbel SE. A comparison of fixation methods in adolescent patients with diaphyseal forearm fractures. Injury. 2018;49:2053\u20137.","journal-title":"Injury."},{"key":"1656_CR19","doi-asserted-by":"publisher","first-page":"201","DOI":"10.1007\/s00590-014-1489-x","volume":"25","author":"J Truntzer","year":"2015","unstructured":"Truntzer J, Vopat ML, Kane PM, Christino MA, Katarincic J, Vopat BG. Forearm diaphyseal fractures in the adolescent population: treatment and management. Eur J Orthop Surg Traumatol. 2015;25:201\u20139.","journal-title":"Eur J Orthop Surg Traumatol."},{"key":"1656_CR20","doi-asserted-by":"publisher","first-page":"598","DOI":"10.1097\/BPO.0b013e3182a11d3b","volume":"33","author":"JE Martus","year":"2013","unstructured":"Martus JE, Preston RK, Schoenecker JG, Lovejoy SA, Green NE, Mencio GA. Complications and outcomes of diaphyseal forearm fracture intramedullary nailing: a comparison of pediatric and adolescent age groups. J Pediatr Orthop. 2013;33:598\u2013607.","journal-title":"J Pediatr Orthop."},{"key":"1656_CR21","doi-asserted-by":"crossref","unstructured":"Morrison MJ, Speirs JN, Chicorelli AM, Garner M, Flynn JJM, Herman MJ. Intramedullary fixation of both bone forearm fractures in children and adolescents: healing correlates with development of the olecranon apophysis. J Pediatr Orthop. 2019.","DOI":"10.1097\/BPO.0000000000001419"},{"key":"1656_CR22","doi-asserted-by":"publisher","first-page":"384","DOI":"10.1097\/01.bot.0000157911.76433.db","volume":"19","author":"H Gao","year":"2005","unstructured":"Gao H, Luo C-F, Zhang C-Q, Shi H-P, Fan C-Y, Zen B-F. Internal fixation of diaphyseal fractures of the forearm by interlocking intramedullary nail: short-term results in eighteen patients. J Orthop Trauma. 2005;19:384\u201391.","journal-title":"J Orthop Trauma."},{"key":"1656_CR23","doi-asserted-by":"publisher","first-page":"1387","DOI":"10.1007\/s00402-014-2058-9","volume":"134","author":"A K\u00f6se","year":"2014","unstructured":"K\u00f6se A, Ayd\u0131n A, Ezirmik N, Can CE, Topal M, Tipi T. Alternative treatment of forearm double fractures: new design intramedullary nail. Arch Orthop Trauma Surg. 2014;134:1387\u201396.","journal-title":"Arch Orthop Trauma Surg."},{"key":"1656_CR24","doi-asserted-by":"publisher","first-page":"1891","DOI":"10.2106\/JBJS.G.01636","volume":"90","author":"YH Lee","year":"2008","unstructured":"Lee YH, Lee SK, Chung MS, Baek GH, Gong HS, Kim KH. Interlocking contoured intramedullary nail fixation for selected diaphyseal fractures of the forearm in adults. J Bone Joint Surg Am. 2008;90:1891\u20138.","journal-title":"J Bone Joint Surg Am."},{"issue":"Suppl 1","key":"1656_CR25","doi-asserted-by":"publisher","first-page":"S16","DOI":"10.1016\/j.injury.2013.10.040","volume":"45","author":"G Saka","year":"2014","unstructured":"Saka G, Saglam N, Kurtulmu\u015f T, Avc\u0131 CC, Akpinar F, Kovaci H, et al. New interlocking intramedullary radius and ulna nails for treating forearm diaphyseal fractures in adults: a retrospective study. Injury. 2014;45(Suppl 1):S16\u201323.","journal-title":"Injury."},{"key":"1656_CR26","doi-asserted-by":"publisher","first-page":"583","DOI":"10.1007\/s00113-004-0790-2","volume":"107","author":"A Hofmann","year":"2004","unstructured":"Hofmann A, Hessmann MH, Rudig L, K\u00fcchle R, Rommens PM. Intramedullary osteosynthesis of the ulna in revision surgery. Unfallchirurg. 2004;107:583\u201392.","journal-title":"Unfallchirurg."},{"key":"1656_CR27","doi-asserted-by":"publisher","first-page":"391","DOI":"10.1016\/j.hcl.2010.04.002","volume":"26","author":"S Rehman","year":"2010","unstructured":"Rehman S, Sokunbi G. Intramedullary fixation of forearm fractures. Hand Clin. 2010;26:391\u2013401 vii.","journal-title":"Hand Clin."},{"key":"1656_CR28","first-page":"91","volume":"39-A","author":"FP Sage","year":"1957","unstructured":"Sage FP, Smith H. Medullary fixation of forearm fractures. J Bone Joint Surg Am. 1957;39-A:91\u20138.","journal-title":"J Bone Joint Surg Am."},{"key":"1656_CR29","doi-asserted-by":"crossref","unstructured":"Street DM. Intramedullary forearm nailing. Clin Orthop Relat Res. 1986:219\u201330.","DOI":"10.1097\/00003086-198611000-00023"},{"key":"1656_CR30","doi-asserted-by":"publisher","first-page":"309","DOI":"10.1007\/s00402-006-0122-9","volume":"126","author":"A Weckbach","year":"2006","unstructured":"Weckbach A, Blattert TR, Weisser C. Interlocking nailing of forearm fractures. Arch Orthop Trauma Surg. 2006;126:309\u201315.","journal-title":"Arch Orthop Trauma Surg."},{"key":"1656_CR31","doi-asserted-by":"publisher","first-page":"697","DOI":"10.4103\/ortho.IJOrtho_79_16","volume":"51","author":"I Azboy","year":"2017","unstructured":"Azboy I, Demirta\u015f A, Alemdar C, Gem M, Uzel K, Arslan H. A newly designed intramedullary nail for the treatment of diaphyseal forearm fractures in adults. Indian J Orthop. 2017;51:697\u2013703.","journal-title":"Indian J Orthop."},{"key":"1656_CR32","doi-asserted-by":"publisher","first-page":"198","DOI":"10.1097\/00005131-199506000-00004","volume":"9","author":"DJ Jones","year":"1995","unstructured":"Jones DJ, Henley MB, Schemitsch EH, Tencer AF. A biomechanical comparison of two methods of fixation of fractures of the forearm. J Orthop Trauma. 1995;9:198\u2013206.","journal-title":"J Orthop Trauma."},{"key":"1656_CR33","first-page":"305","volume":"85","author":"SK Lee","year":"2019","unstructured":"Lee SK, Kim YH, Kim SM, Choy WS. A comparative study of three different surgical methods for both-forearm-bone fractures in adults. Acta Orthop Belg. 2019;85:305\u201316.","journal-title":"Acta Orthop Belg."},{"key":"1656_CR34","doi-asserted-by":"publisher","first-page":"1691","DOI":"10.1007\/s00402-014-2079-4","volume":"134","author":"C-K Yao","year":"2014","unstructured":"Yao C-K, Lin K-C, Tarng Y-W, Chang W-N, Renn J-H. Removal of forearm plate leads to a high risk of refracture: decision regarding implant removal after fixation of the forearm and analysis of risk factors of refracture. Arch Orthop Trauma Surg. 2014;134:1691\u20137.","journal-title":"Arch Orthop Trauma Surg."},{"key":"1656_CR35","doi-asserted-by":"publisher","first-page":"1195","DOI":"10.1016\/j.jse.2016.01.018","volume":"25","author":"RM Houwert","year":"2016","unstructured":"Houwert RM, Smeeing DPJ, Ahmed Ali U, Hietbrink F, Kruyt MC, van der Meijden OA. Plate fixation or intramedullary fixation for midshaft clavicle fractures: a systematic review and meta-analysis of randomized controlled trials and observational studies. J Shoulder Elbow Surg. 2016;25:1195\u2013203.","journal-title":"J Shoulder Elbow Surg."},{"key":"1656_CR36","doi-asserted-by":"publisher","first-page":"1175","DOI":"10.1243\/09544119JEIM409","volume":"222","author":"R Zdero","year":"2008","unstructured":"Zdero R, Olsen M, Bougherara H, Schemitsch EH. Cancellous bone screw purchase: a comparison of synthetic femurs, human femurs, and finite element analysis. Proc Inst Mech Eng H. 2008;222:1175\u201383.","journal-title":"Proc Inst Mech Eng H."},{"key":"1656_CR37","doi-asserted-by":"publisher","first-page":"525","DOI":"10.1016\/0021-9290(95)00084-4","volume":"29","author":"L Cristofolini","year":"1996","unstructured":"Cristofolini L, Viceconti M, Cappello A, Toni A. Mechanical validation of whole bone composite femur models. J Biomech. 1996;29:525\u201335.","journal-title":"J Biomech."}],"container-title":["Journal of Orthopaedic Surgery and Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13018-020-01656-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s13018-020-01656-z\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13018-020-01656-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,4,19]],"date-time":"2021-04-19T23:49:23Z","timestamp":1618876163000},"score":1,"resource":{"primary":{"URL":"https:\/\/josr-online.biomedcentral.com\/articles\/10.1186\/s13018-020-01656-z"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,4,20]]},"references-count":37,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2020,12]]}},"alternative-id":["1656"],"URL":"https:\/\/doi.org\/10.1186\/s13018-020-01656-z","relation":{},"ISSN":["1749-799X"],"issn-type":[{"value":"1749-799X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,4,20]]},"assertion":[{"value":"9 February 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"27 March 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"20 April 2020","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Not applicable.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"No financial biases exist for any author. On behalf of all authors, the corresponding author states that there is no conflict of interest.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"158"}}