{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,27]],"date-time":"2026-02-27T04:24:44Z","timestamp":1772166284598,"version":"3.50.1"},"reference-count":24,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2020,5,29]],"date-time":"2020-05-29T00:00:00Z","timestamp":1590710400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2020,5,29]],"date-time":"2020-05-29T00:00:00Z","timestamp":1590710400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Orthop Surg Res"],"published-print":{"date-parts":[[2020,12]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>During drilling of bone, which is common in clinical surgeries, heat generation increases local temperature in the drilling site. Transmission of excessive heat to the surrounding bone tissue can cause thermal osteonecrosis. Consequently, it may lead to failure of implants and fixation screws or delay in healing process. Using cooling is a method for limiting temperature elevation.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Materials and methods<\/jats:title>\n                    <jats:p>In this study, through comparing three conditions of drilling without cooling, external cooling with normal saline, and external cooling with OpSite spray, the efficiency of OpSite as coolant is studied. In this regard, 2 drill bit diameters, 3 drilling speeds, and 3 drilling feed-rates are considered as drilling variables in the experiments.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>For the whole experiments, while cooling with normal saline resulted in lower maximum temperatures than without cooling condition, OpSite had even better results and limited the temperature elevation during drilling of bone efficiently.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>OpSite spray, which has lower infection risks than normal saline on one hand and lower maximum temperature rise with all combinations of drilling parameters on the other hand, can be considered in clinical surgeries for cooling applications.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s13018-020-01710-w","type":"journal-article","created":{"date-parts":[[2020,5,29]],"date-time":"2020-05-29T07:02:58Z","timestamp":1590735778000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":6,"title":["Appraising efficiency of OpSite as coolant in drilling of bone"],"prefix":"10.1186","volume":"15","author":[{"given":"Mohammad Reza","family":"Effatparvar","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nima","family":"Jamshidi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Alireza","family":"Mosavar","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2020,5,29]]},"reference":[{"key":"1710_CR1","doi-asserted-by":"crossref","first-page":"313","DOI":"10.1016\/j.clinbiomech.2011.10.010","volume":"27","author":"G Augustin","year":"2012","unstructured":"Augustin G, Zigman T, Davila S, Udillijak T, Staroveski T, Brezak D, Babic S. Cortical Bone Drilling and Thermal Osteonecrosis. Clinical Biomechanics. 2012;27:313\u201325.","journal-title":"Clinical Biomechanics"},{"key":"1710_CR2","doi-asserted-by":"crossref","first-page":"300","DOI":"10.1016\/S0531-5131(01)00067-X","volume":"1230","author":"K Denis","year":"2001","unstructured":"Denis K, van Ham G, Vander Sloten J, van Audekercke R, van der Perre G, De Schutter J, Kruth JP, Bellemans J, Fabry G. Influence of Bone Milling Parameters on the Temperature Rise, Milling Forces and Surface Flatness in View of Robot-Assisted Total Knee Arthroplasty. International Congress Series. 2001;1230:300\u20136.","journal-title":"International Congress Series"},{"key":"1710_CR3","doi-asserted-by":"crossref","first-page":"45","DOI":"10.1177\/0954411917742944","volume":"232","author":"E Shakouri","year":"2018","unstructured":"Shakouri E, Haghighi Hassanalideh H, Gholampour S. Experimental Investigation of Temperature Rise in Bone Drilling with Cooling: A Comparison between Modes of without Cooling, Internal Gas Cooling, and External Liquid Cooling. Proceedings of the Institution of Mechanical Engineers, Part H. 2018;232:45\u201353.","journal-title":"Proceedings of the Institution of Mechanical Engineers, Part H"},{"key":"1710_CR4","doi-asserted-by":"crossref","first-page":"629","DOI":"10.3109\/17453678408992410","volume":"55","author":"AR Eriksson","year":"1984","unstructured":"Eriksson AR, Albrektsson T, Albrektsson B. Heat Caused by Drilling Cortical Bone: Temperature Measured in vivo in Patients and Animals. Acta Orthopaedica Scandinavica. 1984;55:629\u201331.","journal-title":"Acta Orthopaedica Scandinavica"},{"key":"1710_CR5","doi-asserted-by":"crossref","first-page":"425","DOI":"10.5545\/sv-jme.2012.928","volume":"59","author":"S den Dunnen","year":"2013","unstructured":"den Dunnen S, Kraaij G, Biskup C, Kerkhoffs GMMJ, Tuijthof GJM. Pure Waterjet Drilling of Articular Bone: An in vitro Feasibility Study. Strojniski Vestnik - Journal of Mechanical Engineering. 2013;59:425\u201332.","journal-title":"Strojniski Vestnik - Journal of Mechanical Engineering"},{"key":"1710_CR6","unstructured":"Kalidindi V (2004) Optimization of Drill Design and Coolant Systems during Dental Implant Surgery. PhD thesis, University of Kentucky, USA."},{"key":"1710_CR7","doi-asserted-by":"crossref","first-page":"1478","DOI":"10.1016\/j.ijom.2016.05.020","volume":"45","author":"SC M\u00f6hlhenrich","year":"2016","unstructured":"M\u00f6hlhenrich SC, Abouridouane M, Heussen N, H\u00f6lzle F, Klocke F, Modabber A. Thermal Evaluation by Infrared Measurement of implant site preparation between Single and Gradual Drilling in Artificial Bone Blocks of Different Densities. International Journal of Oral and Maxillofacial Surgery. 2016;45:1478\u201384.","journal-title":"International Journal of Oral and Maxillofacial Surgery"},{"key":"1710_CR8","doi-asserted-by":"crossref","first-page":"71","DOI":"10.1007\/s00402-007-0427-3","volume":"128","author":"G Augustin","year":"2008","unstructured":"Augustin G, Davila S, Mihoci K, Udiljak T, Vedrina SD, Antabak A. Thermal Osteonecrosis and Bone Drilling Parameters Revisited. Archives of Orthopaedic and Trauma Surgery. 2008;128:71\u20137.","journal-title":"Archives of Orthopaedic and Trauma Surgery"},{"key":"1710_CR9","doi-asserted-by":"crossref","first-page":"685","DOI":"10.1016\/S1350-4533(01)00016-9","volume":"22","author":"KN Bachus","year":"2000","unstructured":"Bachus KN, Rondina MT, Hutchinson DT. The Effects of Drilling Force on Cortical Temperatures and Their Duration: An in vitro Study. Medical Engineering and Physics. 2000;22:685\u201391.","journal-title":"Medical Engineering and Physics"},{"key":"1710_CR10","doi-asserted-by":"crossref","first-page":"305","DOI":"10.1115\/1.1535190","volume":"1253","author":"SRH Davidson","year":"2003","unstructured":"Davidson SRH, James DF. Drilling in Bone: Modeling Heat Generation and Temperature Distribution. Journal of Biomechanical Engineering. 2003;1253:305\u201314.","journal-title":"Journal of Biomechanical Engineering"},{"key":"1710_CR11","doi-asserted-by":"crossref","unstructured":"Bertollo N, Walsh WR (2011) Drilling of Bone: Practicality, Limitations and Complications Associated with Surgical Drill-Bits. Biomechanics in Applications: 53\u201383.","DOI":"10.5772\/20931"},{"key":"1710_CR12","doi-asserted-by":"crossref","first-page":"1221","DOI":"10.1016\/j.medengphy.2011.05.013","volume":"33","author":"F Karaca","year":"2011","unstructured":"Karaca F, Aksakal B, K\u00f6m M. Influence of Orthopaedic Drilling Parameters on Temperature and Histopathology of Bovine Tibia: An in vitro Study. Medical Engineering and Physics. 2011;33:1221\u20137.","journal-title":"Medical Engineering and Physics"},{"key":"1710_CR13","doi-asserted-by":"crossref","first-page":"302","DOI":"10.1016\/S0924-0136(99)00155-7","volume":"92","author":"MT Hillery","year":"1999","unstructured":"Hillery MT, Shuaib I. Temperature Effects in the Drilling of Human and Bovine Bone. Journal of Materials Processing Technology. 1999;92:302\u20138.","journal-title":"Journal of Materials Processing Technology"},{"key":"1710_CR14","first-page":"103","volume":"2","author":"T Udiljak","year":"2007","unstructured":"Udiljak T, Ciglar D, Skoric S. Investigation into Bone Drilling and Thermal Bone Necrosis. Advances in Production Engineering and Management. 2007;2:103\u201312.","journal-title":"Advances in Production Engineering and Management"},{"key":"1710_CR15","doi-asserted-by":"crossref","first-page":"293","DOI":"10.1034\/j.1600-0501.2002.130309.x","volume":"13","author":"IC Benington","year":"2002","unstructured":"Benington IC, Biagioni PA, Briggs J, Shearidan S, Lamey PJ. Thermal changes observed at implant sites during internal and external irrigation. Clinical Oral Implants Research. 2002;13:293\u20137.","journal-title":"Clinical Oral Implants Research"},{"key":"1710_CR16","doi-asserted-by":"crossref","first-page":"867","DOI":"10.1007\/s00170-006-0668-2","volume":"3","author":"E Bagci","year":"2007","unstructured":"Bagci E, Ozcelik B. Effects of Different Cooling Conditions on Twist Drill Temperature. International Journal of Advanced Manufacturing Technology. 2007;3:867\u201377.","journal-title":"International Journal of Advanced Manufacturing Technology"},{"key":"1710_CR17","doi-asserted-by":"crossref","first-page":"294","DOI":"10.1111\/j.1600-0501.2008.01643.x","volume":"20","author":"BC Sener","year":"2009","unstructured":"Sener BC, Dergin G, Gursoy B, Kelesoglu E, Slih I. Effects of Irrigation on Heat Control in vitro at Different Drilling Depths. Clinical Oral Implants Research. 2009;20:294\u20138.","journal-title":"Clinical Oral Implants Research"},{"issue":"8","key":"1710_CR18","doi-asserted-by":"crossref","first-page":"768","DOI":"10.1111\/j.1464-5491.1994.tb00351.x","volume":"11","author":"A.V.M. Foster","year":"1994","unstructured":"Foster AV1, Eaton C, McConville DO, Edmonds ME (1994) Application of OpSite Film: A New and Effective Treatment of Painful Diabetic Neuropathy. Diabetic Medicine. 11: 768\u2013772.","journal-title":"Diabetic Medicine"},{"key":"1710_CR19","doi-asserted-by":"crossref","first-page":"330","DOI":"10.1177\/0954411914524933","volume":"228","author":"E Shakouri","year":"2014","unstructured":"Shakouri E, Sadeghi MH, Maerefat M, Shajari S. Experimental and Analytical Investigation of the Thermal Necrosis in High-Speed Drilling of Bone. Proceedings of the Institution of Mechanical Engineers, Part H. 2014;228:330\u201341.","journal-title":"Proceedings of the Institution of Mechanical Engineers, Part H"},{"key":"1710_CR20","doi-asserted-by":"crossref","first-page":"261","DOI":"10.1016\/j.medengphy.2013.08.006","volume":"36","author":"W Wang","year":"2014","unstructured":"Wang W, Shi Y, Yang N, Yuan X. Experimental Analysis of Drilling Process in Cortical Bone. Medical Engineering and Physics. 2014;36:261\u20136.","journal-title":"Medical Engineering and Physics"},{"key":"1710_CR21","doi-asserted-by":"crossref","first-page":"13","DOI":"10.1016\/j.commatsci.2012.03.012","volume":"60","author":"S Sezek","year":"2012","unstructured":"Sezek S, Aksakal B, Karaca F. Influence of drill parameters on bone temperature and necrosis: a FEM modelling and in vitro experiments. Computational Materials Science. 2012;60:13\u20138.","journal-title":"Computational Materials Science"},{"key":"1710_CR22","doi-asserted-by":"crossref","first-page":"15","DOI":"10.1016\/j.jcot.2013.01.002","volume":"4","author":"RK Pandey","year":"2013","unstructured":"Pandey RK, Panda SS. Drilling of bone: a comprehensive review. Journal of Clinical Orthopaedics and Trauma. 2013;4:15\u201330.","journal-title":"Journal of Clinical Orthopaedics and Trauma"},{"key":"1710_CR23","doi-asserted-by":"crossref","first-page":"260","DOI":"10.33899\/rden.2010.9016","volume":"10","author":"AN Al-Dabag","year":"2010","unstructured":"Al-Dabag AN, Sultan AA. Effect of cooling an irrigation solution during preparation of implant site on heat generation using elite system for implant (experimental study). Al-Rafidain Dental Journal. 2010;10:260\u20134.","journal-title":"Al-Rafidain Dental Journal"},{"key":"1710_CR24","first-page":"e506","volume":"22","author":"A Sindel","year":"2017","unstructured":"Sindel A, Dereci \u00d6, Hatipo\u011flu M, Altay MA, \u00d6zalp \u00d6, \u00d6zt\u00fcrk A. The effects of irrigation volume to the heat generation during implant surgery. Medicina Oral Patologia Oral y Cirugia Bucal. 2017;22:e506\u201311.","journal-title":"Medicina Oral Patologia Oral y Cirugia Bucal"}],"container-title":["Journal of Orthopaedic Surgery and Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13018-020-01710-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s13018-020-01710-w\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13018-020-01710-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,5,28]],"date-time":"2021-05-28T19:29:56Z","timestamp":1622230196000},"score":1,"resource":{"primary":{"URL":"https:\/\/josr-online.biomedcentral.com\/articles\/10.1186\/s13018-020-01710-w"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,5,29]]},"references-count":24,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2020,12]]}},"alternative-id":["1710"],"URL":"https:\/\/doi.org\/10.1186\/s13018-020-01710-w","relation":{"has-preprint":[{"id-type":"doi","id":"10.21203\/rs.2.20897\/v2","asserted-by":"object"},{"id-type":"doi","id":"10.21203\/rs.2.20897\/v1","asserted-by":"object"},{"id-type":"doi","id":"10.21203\/rs.2.20897\/v3","asserted-by":"object"}]},"ISSN":["1749-799X"],"issn-type":[{"value":"1749-799X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,5,29]]},"assertion":[{"value":"10 January 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 May 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"29 May 2020","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Not applicable.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they have no competing interests.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"197"}}