{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,18]],"date-time":"2026-08-18T23:07:41Z","timestamp":1787094461934,"version":"build-2736575974"},"reference-count":39,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2020,7,29]],"date-time":"2020-07-29T00:00:00Z","timestamp":1595980800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2020,7,29]],"date-time":"2020-07-29T00:00:00Z","timestamp":1595980800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Orthop Surg Res"],"published-print":{"date-parts":[[2020,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec><jats:title>Background<\/jats:title><jats:p>Interlaminar stabilization and interspinous stabilization are two newer minimally invasive methods for lumbar spine stabilization, used frequently in conjunction with lumbar decompression to treat lumbar stenosis. The two methods share certain similarities, therefore, frequently being categorized together. However, the two methods offer distinct biomechanical properties, which affect their respective effectiveness and surgical success.<\/jats:p><\/jats:sec><jats:sec><jats:title>Objective<\/jats:title><jats:p>To compare the biomechanical characteristics of interlaminar stabilization after lumbar decompression (ILS) and interspinous stabilization after lumbar decompression (ISS). For comparison, lumbar decompression alone (DA) and decompression with instrumented fusion (DF) were also included in the biomechanical analysis.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>Four finite element models were constructed, i.e., DA, DF, ISS, and ILS. To minimize device influence and focus on the biomechanical properties of different methods, Coflex device as a model system was placed at different position for the comparison of ISS and ILS. The range of motion (ROM) and disc stress peak at the surgical and adjacent levels were compared among the four surgical constructs. The stress peak of the spinous process, whole device, and device wing was compared between ISS and ILS.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>Compared with DA, the ROM and disc stress at the surgical level in ILS or ISS were much lower in extension. The ROM and disc stress at the surgical level in ILS were 1.27\u00b0 and 0.36\u2009MPa, respectively, and in ISS 1.51\u00b0and 0.55\u2009MPa, respectively in extension. This is compared with 4.71\u00b0 and 1.44\u2009MPa, respectively in DA. ILS (2.06\u20134.85\u00b0 and 0.37\u20130.98\u2009MPa, respectively) or ISS (2.07\u20134.78\u00b0 and 0.37\u20130.98\u2009MPa, respectively) also induced much lower ROM and disc stress at the adjacent levels compared with DF (2.50\u20137.20\u00b0 and 0.37\u20131.20\u2009MPa, respectively). ILS further reduced the ROM and disc stress at the surgical level by 8% and 25%, respectively, compared to ISS. The stress peak of the spinous process in ILS was significantly lower than that in ISS (13.93\u2013101\u2009MPa vs. 31.08\u2013172.5\u2009MPa). In rotation, ILS yielded a much lower stress peak in the instrumentation wing than ISS (128.7\u2009MPa vs. 222.1\u2009MPa).<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusion<\/jats:title><jats:p>ILS and ISS partly address the issues of segmental instability in DA and hypermobility and overload at the adjacent levels in DF. ILS achieves greater segmental stability and results in a lower disc stress, compared to ISS. In addition, ILS reduces the risk of spinous process fracture and device failure.<\/jats:p><\/jats:sec>","DOI":"10.1186\/s13018-020-01812-5","type":"journal-article","created":{"date-parts":[[2020,7,29]],"date-time":"2020-07-29T13:05:10Z","timestamp":1596027910000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":13,"title":["Interlaminar stabilization offers greater biomechanical advantage compared to interspinous stabilization after lumbar decompression: a finite element analysis"],"prefix":"10.1186","volume":"15","author":[{"given":"Teng","family":"Lu","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8180-8578","authenticated-orcid":false,"given":"Yi","family":"Lu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2020,7,29]]},"reference":[{"issue":"19","key":"1812_CR1","doi-asserted-by":"publisher","first-page":"1584","DOI":"10.1097\/BRS.0000000000000486","volume":"39","author":"CK Kepler","year":"2014","unstructured":"Kepler CK, Vaccaro AR, Hilibrand AS, Anderson DG, Rihn JA, Albert TJ, et al. National trends in the use of fusion techniques to treat degenerative spondylolisthesis. Spine (Phila Pa 1976). 2014;39(19):1584\u20139.","journal-title":"Spine (Phila Pa 1976)."},{"issue":"11","key":"1812_CR2","doi-asserted-by":"publisher","first-page":"916","DOI":"10.1097\/BRS.0b013e3182833e7c","volume":"38","author":"HW Bae","year":"2013","unstructured":"Bae HW, Rajaee SS, Kanim LE. Nationwide trends in the surgical management of lumbar spinal stenosis. Spine (Phila Pa 1976). 2013;38(11):916\u201326.","journal-title":"Spine (Phila Pa 1976)."},{"issue":"15","key":"1812_CR3","doi-asserted-by":"publisher","first-page":"1424","DOI":"10.1056\/NEJMoa1508788","volume":"374","author":"Z Ghogawala","year":"2016","unstructured":"Ghogawala Z, Dziura J, Butler WE, Dai F, Terrin N, Magge SN, et al. Laminectomy plus fusion versus laminectomy alone for lumbar spondylolisthesis. N Engl J Med. 2016;374(15):1424\u201334.","journal-title":"N Engl J Med."},{"issue":"15","key":"1812_CR4","doi-asserted-by":"publisher","first-page":"1413","DOI":"10.1056\/NEJMoa1513721","volume":"374","author":"P Forsth","year":"2016","unstructured":"Forsth P, Olafsson G, Carlsson T, Frost A, Borgstrom F, Fritzell P, et al. A randomized, controlled trial of fusion surgery for lumbar spinal stenosis. N Engl J Med. 2016;374(15):1413\u201323.","journal-title":"N Engl J Med."},{"issue":"4","key":"1812_CR5","doi-asserted-by":"publisher","DOI":"10.3171\/2015.7.FOCUS15292","volume":"39","author":"DS Chun","year":"2015","unstructured":"Chun DS, Baker KC, Hsu WK. Lumbar pseudarthrosis: a review of current diagnosis and treatment. Neurosurg Focus. 2015;39(4):E10.","journal-title":"Neurosurg Focus."},{"issue":"2","key":"1812_CR6","doi-asserted-by":"publisher","first-page":"242","DOI":"10.1016\/j.clinbiomech.2007.09.004","volume":"23","author":"A Kettler","year":"2008","unstructured":"Kettler A, Drumm J, Heuer F, Haeussler K, Mack C, Claes L, et al. Can a modified interspinous spacer prevent instability in axial rotation and lateral bending? A biomechanical in vitro study resulting in a new idea. Clin Biomech (Bristol, Avon). 2008;23(2):242\u20137.","journal-title":"Clin Biomech (Bristol, Avon)"},{"issue":"11","key":"1812_CR7","doi-asserted-by":"publisher","first-page":"969","DOI":"10.1080\/10255842.2010.502894","volume":"14","author":"CC Lo","year":"2011","unstructured":"Lo CC, Tsai KJ, Chen SH, Zhong ZC, Hung C. Biomechanical effect after Coflex and Coflex rivet implantation for segmental instability at surgical and adjacent segments: a finite element analysis. Comput Methods Biomech Biomed Engin. 2011;14(11):969\u201378.","journal-title":"Comput Methods Biomech Biomed Engin."},{"issue":"2","key":"1812_CR8","doi-asserted-by":"publisher","first-page":"189","DOI":"10.1007\/s12178-017-9401-z","volume":"10","author":"M Pintauro","year":"2017","unstructured":"Pintauro M, Duffy A, Vahedi P, Rymarczuk G, Heller J. Interspinous implants: are the new implants better than the last generation? A review. Curr Rev Musculoskelet Med. 2017;10(2):189\u201398.","journal-title":"Curr Rev Musculoskelet Med."},{"key":"1812_CR9","doi-asserted-by":"publisher","first-page":"57","DOI":"10.1016\/j.ijsu.2017.01.074","volume":"39","author":"XW Zhao","year":"2017","unstructured":"Zhao XW, Ma JX, Ma XL, Li F, He WW, Jiang X, et al. Interspinous process devices(IPD) alone versus decompression surgery for lumbar spinal stenosis(LSS): a systematic review and meta-analysis of randomized controlled trials. Int J Surg. 2017;39:57\u201364.","journal-title":"Int J Surg."},{"key":"1812_CR10","doi-asserted-by":"publisher","first-page":"74","DOI":"10.1016\/j.clineuro.2018.06.030","volume":"172","author":"Z Mo","year":"2018","unstructured":"Mo Z, Li D, Zhang R, Chang M, Yang B, Tang S. Comparative effectiveness and safety of posterior lumbar interbody fusion, Coflex, Wallis, and X-stop for lumbar degenerative diseases: a systematic review and network meta-analysis. Clin Neurol Neurosurg. 2018;172:74\u201381.","journal-title":"Clin Neurol Neurosurg."},{"key":"1812_CR11","doi-asserted-by":"publisher","first-page":"177","DOI":"10.1016\/j.wneu.2015.08.069","volume":"85","author":"N Lee","year":"2016","unstructured":"Lee N, Shin DA, Kim KN, Yoon DH, Ha Y, Shin HC, et al. Paradoxical radiographic changes of Coflex interspinous device with minimum 2-year follow-up in lumbar spinal stenosis. World Neurosurg. 2016;85:177\u201384.","journal-title":"World Neurosurg."},{"key":"1812_CR12","doi-asserted-by":"publisher","first-page":"15","DOI":"10.14444\/2015","volume":"9","author":"HW Bae","year":"2015","unstructured":"Bae HW, Lauryssen C, Maislin G, Leary S, Musacchio MJ Jr. Therapeutic sustainability and durability of coflex interlaminar stabilization after decompression for lumbar spinal stenosis: a four year assessment. Int J Spine Surg. 2015;9:15.","journal-title":"Int J Spine Surg."},{"issue":"4","key":"1812_CR13","first-page":"6097","volume":"8","author":"X Liu","year":"2015","unstructured":"Liu X, Liu Y, Lian X, Xu J. Magnetic resonance imaging on disc degeneration changes after implantation of an interspinous spacer and fusion of the adjacent segment. Int J Clin Exp Med. 2015;8(4):6097\u2013102.","journal-title":"Int J Clin Exp Med."},{"issue":"2","key":"1812_CR14","doi-asserted-by":"publisher","first-page":"161","DOI":"10.4184\/asj.2014.8.2.161","volume":"8","author":"N Kumar","year":"2014","unstructured":"Kumar N, Shah SM, Ng YH, Pannierselvam VK, Dasde S, Shen L. Role of coflex as an adjunct to decompression for symptomatic lumbar spinal stenosis. Asian Spine J. 2014;8(2):161\u20139.","journal-title":"Asian Spine J."},{"issue":"4","key":"1812_CR15","doi-asserted-by":"publisher","first-page":"406","DOI":"10.3171\/2017.11.SPINE17643","volume":"28","author":"S Schmidt","year":"2018","unstructured":"Schmidt S, Franke J, Rauschmann M, Adelt D, Bonsanto MM, Sola S. Prospective, randomized, multicenter study with 2-year follow-up to compare the performance of decompression with and without interlaminar stabilization. J Neurosurg Spine. 2018;28(4):406\u201315.","journal-title":"J Neurosurg Spine."},{"issue":"7","key":"1812_CR16","doi-asserted-by":"publisher","DOI":"10.1371\/journal.pone.0199623","volume":"13","author":"AW Poetscher","year":"2018","unstructured":"Poetscher AW, Gentil AF, Ferretti M, Lenza M. Interspinous process devices for treatment of degenerative lumbar spine stenosis: a systematic review and meta-analysis. PLoS One. 2018;13(7):e0199623.","journal-title":"PLoS One."},{"issue":"2","key":"1812_CR17","doi-asserted-by":"publisher","first-page":"174","DOI":"10.3171\/2013.4.SPINE12636","volume":"19","author":"R Davis","year":"2013","unstructured":"Davis R, Auerbach JD, Bae H, Errico TJ. Can low-grade spondylolisthesis be effectively treated by either coflex interlaminar stabilization or laminectomy and posterior spinal fusion? Two-year clinical and radiographic results from the randomized, prospective, multicenter US investigational device exemption trial: clinical article. J Neurosurg Spine. 2013;19(2):174\u201384.","journal-title":"J Neurosurg Spine."},{"issue":"13","key":"1812_CR18","doi-asserted-by":"crossref","first-page":"2517","DOI":"10.3760\/cma.j.issn.0366-6999.20130304","volume":"126","author":"L Zang","year":"2013","unstructured":"Zang L, Du P, Hai Y, Su QJ, Lu SB, Liu T. Device related complications of the Coflex interspinous process implant for the lumbar spine. Chin Med J (Engl). 2013;126(13):2517\u201322.","journal-title":"Chin Med J (Engl)."},{"issue":"11","key":"1812_CR19","doi-asserted-by":"publisher","first-page":"2199","DOI":"10.1007\/s00264-013-2006-2","volume":"37","author":"C Xu","year":"2013","unstructured":"Xu C, Ni WF, Tian NF, Hu XQ, Li F, Xu HZ. Complications in degenerative lumbar disease treated with a dynamic interspinous spacer (Coflex). Int Orthop. 2013;37(11):2199\u2013204.","journal-title":"Int Orthop."},{"issue":"3","key":"1812_CR20","doi-asserted-by":"publisher","first-page":"244","DOI":"10.1016\/j.spinee.2009.10.010","volume":"10","author":"FT Trautwein","year":"2010","unstructured":"Trautwein FT, Lowery GL, Wharton ND, Hipp JA, Chomiak RJ. Determination of the in vivo posterior loading environment of the Coflex interlaminar-interspinous implant. Spine J. 2010;10(3):244\u201351.","journal-title":"Spine J."},{"issue":"8","key":"1812_CR21","doi-asserted-by":"publisher","first-page":"1049","DOI":"10.1007\/s00586-008-0657-2","volume":"17","author":"HJ Wilke","year":"2008","unstructured":"Wilke HJ, Drumm J, Haussler K, Mack C, Steudel WI, Kettler A. Biomechanical effect of different lumbar interspinous implants on flexibility and intradiscal pressure. Eur Spine J. 2008;17(8):1049\u201356.","journal-title":"Eur Spine J."},{"key":"1812_CR22","doi-asserted-by":"publisher","first-page":"e1112","DOI":"10.1016\/j.wneu.2019.04.051","volume":"127","author":"H Shen","year":"2019","unstructured":"Shen H, Fogel GR, Zhu J, Liao Z, Liu W. Biomechanical analysis of different lumbar interspinous process devices: a finite element study. World Neurosurg. 2019;127:e1112\u20139.","journal-title":"World Neurosurg."},{"key":"1812_CR23","doi-asserted-by":"publisher","first-page":"e1331","DOI":"10.1016\/j.wneu.2018.09.086","volume":"120","author":"H Gu","year":"2018","unstructured":"Gu H, Chang Y, Zeng S, Zheng X, Zhang R, Zhan S, et al. Wallis interspinous spacer for treatment of primary lumbar disc herniation: three-year results of a randomized controlled trial. World Neurosurg. 2018;120:e1331\u20136.","journal-title":"World Neurosurg."},{"key":"1812_CR24","doi-asserted-by":"crossref","unstructured":"Guo TM, Lu J, Xing YL, Liu GX, Zhu HY, Yang L, et al. A 3-Dimensional finite element analysis of adjacent segment disk degeneration induced by transforaminal lumbar interbody fusion after pedicle screw fixation. World Neurosurg. 2018.","DOI":"10.1016\/j.wneu.2018.11.195"},{"key":"1812_CR25","doi-asserted-by":"publisher","first-page":"e1120","DOI":"10.1016\/j.wneu.2018.03.158","volume":"114","author":"Z Zhang","year":"2018","unstructured":"Zhang Z, Fogel GR, Liao Z, Sun Y, Liu W. Biomechanical analysis of lateral lumbar interbody fusion constructs with various fixation options: based on a validated finite element model. World Neurosurg. 2018;114:e1120\u20139.","journal-title":"World Neurosurg."},{"key":"1812_CR26","doi-asserted-by":"publisher","first-page":"E114","DOI":"10.1016\/j.wneu.2018.02.073","volume":"114","author":"X Zhao","year":"2018","unstructured":"Zhao X, Du L, Xie YZ, Zhao J. Effect of lumbar lordosis on the adjacent segment in transforaminal lumbar interbody fusion: a finite element analysis. World Neurosurg. 2018;114:E114\u201320.","journal-title":"World Neurosurg."},{"issue":"3","key":"1812_CR27","doi-asserted-by":"publisher","first-page":"341","DOI":"10.1016\/j.jbiomech.2008.11.024","volume":"42","author":"LM Ruberte","year":"2009","unstructured":"Ruberte LM, Natarajan RN, Andersson GBJ. Influence of single-level lumbar degenerative disc disease on the behavior of the adjacent segments-a finite element model study. J Biomech. 2009;42(3):341\u20138.","journal-title":"J Biomech."},{"issue":"5","key":"1812_CR28","doi-asserted-by":"publisher","first-page":"1386","DOI":"10.3349\/ymj.2014.55.5.1386","volume":"55","author":"HJ Kim","year":"2014","unstructured":"Kim HJ, Kang KT, Chang BS, Lee CK, Kim JW, Yeom JS. Biomechanical analysis of fusion segment rigidity upon stress at both the fusion and adjacent segments: a comparison between unilateral and bilateral pedicle screw fixation. Yonsei Med J. 2014;55(5):1386\u201394.","journal-title":"Yonsei Med J."},{"key":"1812_CR29","doi-asserted-by":"publisher","first-page":"126","DOI":"10.1016\/j.wneu.2016.07.106","volume":"95","author":"L Wang","year":"2016","unstructured":"Wang L, Zhang B, Chen S, Lu X, Li ZY, Guo Q. A validated finite element analysis of facet joint stress in degenerative lumbar scoliosis. World Neurosurg. 2016;95:126\u201333.","journal-title":"World Neurosurg."},{"issue":"22","key":"1812_CR30","doi-asserted-by":"publisher","first-page":"E820","DOI":"10.1097\/BRS.0b013e3181894fb1","volume":"33","author":"CS Shim","year":"2008","unstructured":"Shim CS, Park SW, Lee SH, Lim TJ, Chun K, Kim DH. Biomechanical evaluation of an interspinous stabilizing device. Locker. Spine (Phila Pa 1976). 2008;33(22):E820\u20137.","journal-title":"Locker. Spine (Phila Pa 1976)."},{"key":"1812_CR31","doi-asserted-by":"publisher","first-page":"27","DOI":"10.1016\/j.medengphy.2017.05.004","volume":"46","author":"HC Chen","year":"2017","unstructured":"Chen HC, Wu JL, Huang SC, Zhong ZC, Chiu SL, Lai YS, et al. Biomechanical evaluation of a novel pedicle screw-based interspinous spacer: a finite element analysis. Med Eng Phys. 2017;46:27\u201332.","journal-title":"Med Eng Phys."},{"issue":"3","key":"1812_CR32","doi-asserted-by":"publisher","first-page":"257","DOI":"10.1016\/j.clinbiomech.2006.08.006","volume":"22","author":"MM Panjabi","year":"2007","unstructured":"Panjabi MM. Hybrid multidirectional test method to evaluate spinal adjacent-level effects. Clin Biomech (Bristol, Avon). 2007;22(3):257\u201365.","journal-title":"Clin Biomech (Bristol, Avon)"},{"issue":"2","key":"1812_CR33","doi-asserted-by":"publisher","first-page":"182","DOI":"10.1007\/s12178-017-9413-8","volume":"10","author":"RJ Gala","year":"2017","unstructured":"Gala RJ, Russo GS, Whang PG. Interspinous implants to treat spinal stenosis. Curr Rev Musculoskelet Med. 2017;10(2):182\u20138.","journal-title":"Curr Rev Musculoskelet Med."},{"issue":"4","key":"1812_CR34","doi-asserted-by":"publisher","first-page":"400","DOI":"10.1002\/rcs.1636","volume":"11","author":"A Kulduk","year":"2015","unstructured":"Kulduk A, Altun NS, Senkoylu A. Biomechanical comparison of effects of the Dynesys and Coflex dynamic stabilization systems on range of motion and loading characteristics in the lumbar spine: a finite element study. Int J Med Robot. 2015;11(4):400\u20135.","journal-title":"Int J Med Robot."},{"key":"1812_CR35","doi-asserted-by":"publisher","first-page":"113","DOI":"10.1016\/j.jbiomech.2016.12.021","volume":"52","author":"A Aiyangar","year":"2017","unstructured":"Aiyangar A, Zheng L, Anderst W, Zhang X. Instantaneous centers of rotation for lumbar segmental extension in vivo. J Biomech. 2017;52:113\u201321.","journal-title":"J Biomech."},{"issue":"3","key":"1812_CR36","doi-asserted-by":"publisher","first-page":"371","DOI":"10.1016\/j.jbiomech.2015.12.029","volume":"49","author":"Z Liu","year":"2016","unstructured":"Liu Z, Tsai TY, Wang S, Wu M, Zhong W, Li JS, et al. Sagittal plane rotation center of lower lumbar spine during a dynamic weight-lifting activity. J Biomech. 2016;49(3):371\u20135.","journal-title":"J Biomech."},{"key":"1812_CR37","first-page":"23","volume":"6","author":"DR Wenger","year":"1982","unstructured":"Wenger DR. Evaluation of fixation sites for segmental instrumentation of the human vertebra. Orthop Trans. 1982;6:23\u20134.","journal-title":"Orthop Trans."},{"issue":"15","key":"1812_CR38","doi-asserted-by":"publisher","first-page":"1731","DOI":"10.1097\/01.brs.0000172160.78207.49","volume":"30","author":"N Kumar","year":"2005","unstructured":"Kumar N, Judith MR, Kumar A, Mishra V, Robert MC. Analysis of stress distribution in lumbar interbody fusion. Spine (Phila Pa 1976). 2005;30(15):1731\u20135.","journal-title":"Spine (Phila Pa 1976)."},{"issue":"11","key":"1812_CR39","doi-asserted-by":"publisher","first-page":"947","DOI":"10.1080\/10255842.2010.501762","volume":"14","author":"CC Lo","year":"2011","unstructured":"Lo CC, Tsai KJ, Zhong ZC, Chen SH, Hung C. Biomechanical differences of Coflex-F and pedicle screw fixation combined with TLIF or ALIF--a finite element study. Comput Methods Biomech Biomed Engin. 2011;14(11):947\u201356.","journal-title":"Comput Methods Biomech Biomed Engin."}],"container-title":["Journal of Orthopaedic Surgery and Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13018-020-01812-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s13018-020-01812-5\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13018-020-01812-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,8,11]],"date-time":"2024-08-11T00:09:43Z","timestamp":1723334983000},"score":1,"resource":{"primary":{"URL":"https:\/\/josr-online.biomedcentral.com\/articles\/10.1186\/s13018-020-01812-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,7,29]]},"references-count":39,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2020,12]]}},"alternative-id":["1812"],"URL":"https:\/\/doi.org\/10.1186\/s13018-020-01812-5","relation":{},"ISSN":["1749-799X"],"issn-type":[{"value":"1749-799X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,7,29]]},"assertion":[{"value":"27 March 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"22 July 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"29 July 2020","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"Not applicable","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors declare that they have no competing interests.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"291"}}