{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,13]],"date-time":"2026-03-13T21:17:30Z","timestamp":1773436650518,"version":"3.50.1"},"reference-count":24,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2020,9,1]],"date-time":"2020-09-01T00:00:00Z","timestamp":1598918400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2020,9,1]],"date-time":"2020-09-01T00:00:00Z","timestamp":1598918400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Orthop Surg Res"],"published-print":{"date-parts":[[2020,12]]},"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>A new C2 transpedicular lag screw designed by our team has been used in human cadaver spines for biomechanical testing, and the results showed that the biomechanical properties of the new C2 transpedicular lag screw were better than ordinary screws. The objective of this study is to analyze the clinical efficacy and safety of the new C2 transpedicular lag screw fixation for the treatment of unstable Hangman\u2019s fracture.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>From March 2013 to June 2017, 25 patients who had unstable Hangman\u2019s fractures were operated on with a new C2 transpedicular lag screw fixation. The patients included 18 males and 7 females whose ages ranged from 31 to 62\u2009years (average 45.4 \u00b1 9.3\u2009years). The cause of the injury was a traffic accident in 17 patients and a fall from height in 8 patients. Other associated lesions included rupture of the spleen (1 patient) and rib fractures (2 patients). According to the Levine-Edwards classification, 17 patients were type II and 8 patients were type IIA, and according to the Frankel Neurological Performance scale, 8 cases and 17 cases were graded as spinal cord injury D and E, respectively. Twenty-three cases received bilateral screw fixation, and 2 cases had unilateral screw fixation because another pedicle was chipped. The whole procedure was accomplished with monitoring by \u201cC\u201d-arm fluoroscopy.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>\n                      The mean follow-up time was 36 \u00b1 12 months and ranged from 24 to 60\u2009months. No obvious symptomatic or radiologic postoperative complications were found during the follow-up period. Six cases were restored from D to E while 2 cases remained D according to the American Spinal Injury Association (ASIA) grade. Pre- and postoperative visual analogue scale (VAS) and Neck Disability Index (NDI) were statistically different (\n                      <jats:italic>P<\/jats:italic>\n                      &lt; 0.001). Osseous union was achieved in all cases, and the range of cervical motion recovered to the normal level up to the last follow-up.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>The primary clinical and radiographic efficacies of a new C2 transpedicular lag screw fixation for the treatment of unstable Hangman\u2019s fracture were satisfactory. This approach could be considered a simple, effective, reliable, and economic surgical method for managing unstable Hangman\u2019s fractures.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1186\/s13018-020-01911-3","type":"journal-article","created":{"date-parts":[[2020,9,1]],"date-time":"2020-09-01T09:04:04Z","timestamp":1598951044000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":8,"title":["A new transpedicular lag screw fixation for treatment of unstable Hangman\u2019s fracture: a minimum 2-year follow-up study"],"prefix":"10.1186","volume":"15","author":[{"given":"Yijie","family":"Liu","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yi","family":"Zhu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xuefeng","family":"Li","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jie","family":"Chen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sen","family":"Yang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Huilin","family":"Yang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Weimin","family":"Jiang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2020,9,1]]},"reference":[{"key":"1911_CR1","doi-asserted-by":"publisher","first-page":"642","DOI":"10.3171\/jns.1989.71.5.0642","volume":"71","author":"MN Hadley","year":"1989","unstructured":"Hadley MN, Dickman CA, Browner CM, Sonntag VK. Acute axis fractures: a review of 229 cases. J Neurosurg. 1989;71:642\u20137.","journal-title":"J Neurosurg"},{"key":"1911_CR2","first-page":"633","volume":"60","author":"JM Roda","year":"1984","unstructured":"Roda JM, Castro A, Bl\u00e1zquez MG. Hangman\u2019s fracture with complete dislocation of C-2 on C-3. Case report J Neurosurg. 1984;60:633\u20135.","journal-title":"Case report J Neurosurg"},{"key":"1911_CR3","doi-asserted-by":"publisher","first-page":"141","DOI":"10.3171\/jns.1965.22.2.0141","volume":"22","author":"RC Schneider","year":"1965","unstructured":"Schneider RC, Livingston KE, Cave AJ, Hamilton G. Hangman\u2019s fracture of the cervical spine. J Neurosurg. 1965;22:141\u201354.","journal-title":"J Neurosurg"},{"key":"1911_CR4","unstructured":"Leconte P. luxation des deux premieres vertebres cervicales. In: Judet R (ed) Luxation Congenenitale dela Hanche:Fracture du Cou-de-pied Rachis Cervical. Actualites de Chirurgie Orthopedique de 1\u2019Ho pital Raymond-Poincare Masson, Paris. 1964;3:147-166."},{"key":"1911_CR5","unstructured":"Judet R, Roy-Camille R, Saillant G. Actuallities de chiirugie orthopedique de 1\u2019hopital Raymound-pointcare: fracture du rachis cervical. Masson, Paris, 1970;8:174-196."},{"key":"1911_CR6","first-page":"1141","volume":"33","author":"L Huang","year":"2013","unstructured":"Huang L, Jiang WM, Luo ZP, et al. The design and biomechanical testing of a new transpedicular lag-screw for treatment of Hangman\u2019s fracture. Chinese Journal of Orthopaedics. 2013;33:1141\u20136.","journal-title":"Chinese Journal of Orthopaedics"},{"key":"1911_CR7","doi-asserted-by":"publisher","first-page":"319","DOI":"10.1302\/0301-620X.63B3.7263741","volume":"63","author":"B Effendi","year":"1981","unstructured":"Effendi B, Roy D, Cornish B, Dussault RG, Laurin CA. Fractures of the ring of the axis. A classification based on the analysis of 131 cases. J Bone Joint Surg (Br). 1981;63:319\u201327.","journal-title":"J Bone Joint Surg (Br)"},{"key":"1911_CR8","doi-asserted-by":"publisher","first-page":"217","DOI":"10.2106\/00004623-198567020-00007","volume":"67","author":"AM Levine","year":"1985","unstructured":"Levine AM, Edwards CC. The management of traumatic spondylolisthesis of the axis. J Bone Joint Surg Am. 1985;67:217\u201326.","journal-title":"J Bone Joint Surg Am"},{"key":"1911_CR9","doi-asserted-by":"publisher","first-page":"S90","DOI":"10.1097\/BOT.0000000000000952","volume":"31","author":"H Murphy","year":"2017","unstructured":"Murphy H, Schroeder GD, Shi WJ, et al. Management of Hangman\u2019s fractures: a systematic review. J Orthop Trauma. 2017;31:S90\u20135.","journal-title":"J Orthop Trauma"},{"key":"1911_CR10","doi-asserted-by":"publisher","first-page":"76","DOI":"10.1097\/TA.0000000000000894","volume":"80","author":"JP Sharpe","year":"2016","unstructured":"Sharpe JP, Magnotti LJ, Weinberg JA, Schroeppel TJ, Fabian TC, Croce MA. The old man and the C-spine fracture: impact of halo vest stabilization in patients with blunt cervical spine fractures. J Trauma Acute Care. 2016;80:76\u201380.","journal-title":"J Trauma Acute Care"},{"key":"1911_CR11","doi-asserted-by":"crossref","unstructured":"Ma W, Xu R, Liu J, Sun S, Zhao L, Hu Y et al. Posterior short-segment fixation and fusion in unstable Hangman\u2019s fractures. Spine (Phila Pa 1976). 2011;36:529-533.","DOI":"10.1097\/BRS.0b013e3181d60067"},{"key":"1911_CR12","doi-asserted-by":"publisher","first-page":"809","DOI":"10.1007\/s00586-010-1291-3","volume":"19","author":"CA Mueller","year":"2010","unstructured":"Mueller CA, Roesseler L, Podlogar M, Kovacs A, Kristof RA. Accuracy and complications of transpedicular C2 screw placement without the use of spinal navigation. Eur Spine J. 2010;19:809\u201314.","journal-title":"Eur Spine J"},{"key":"1911_CR13","doi-asserted-by":"crossref","unstructured":"Xie N, Khoo LT, Yuan W, et al. Combined anterior C2-C3 fusion and C2 pedicle screw fixation for the treatment of unstable Hangman\u2019s fracture: a contrast to anterior approach only. Spine (Phila Pa 1976). 2010;35:613-619.","DOI":"10.1097\/BRS.0b013e3181ba3368"},{"key":"1911_CR14","doi-asserted-by":"publisher","first-page":"1641","DOI":"10.1007\/s00586-014-3311-1","volume":"23","author":"H Hur","year":"2014","unstructured":"Hur H, Lee JK, Jang JW, Kim TS, Kim SH. Is it feasible to treat unstable Hangman\u2019s fracture via the primary standard anterior retropharyngeal approach? Eur Spine J. 2014;23:1641\u20137.","journal-title":"Eur Spine J"},{"key":"1911_CR15","doi-asserted-by":"publisher","first-page":"62","DOI":"10.4103\/0974-8237.116541","volume":"3","author":"N Muthukumar","year":"2012","unstructured":"Muthukumar N. C1-C3 lateral mass fusion for type IIa and type III Hangman\u2019s fracture. J Craniovertebr Junction Spine. 2012;3:62\u20136.","journal-title":"J Craniovertebr Junction Spine"},{"key":"1911_CR16","doi-asserted-by":"publisher","first-page":"257","DOI":"10.1007\/s00586-005-0918-2","volume":"15","author":"XF Li","year":"2006","unstructured":"Li XF, Dai LY, Lu H, Chen XD. A systematic review of the management of Hangman\u2019s fractures. Eur Spine J. 2006;15:257\u201369.","journal-title":"Eur Spine J"},{"key":"1911_CR17","doi-asserted-by":"publisher","first-page":"E6166","DOI":"10.1097\/BSD.0000000000000150","volume":"28","author":"C Ge","year":"2015","unstructured":"Ge C, Hao D, He B, Mi B. Anterior cervical discectomy and fusion versus posterior fixation and fusion of C2-3 for unstable Hangman\u2019s fracture. J Spinal Disord Tech. 2015;28:E6166.","journal-title":"J Spinal Disord Tech"},{"key":"1911_CR18","doi-asserted-by":"publisher","first-page":"123","DOI":"10.1007\/s005860050222","volume":"9","author":"EJ M\u00fcller","year":"2000","unstructured":"M\u00fcller EJ, Wick M, Muhr G. Traumatic spondylolisthesis of the axis: treatment rationale based on the stability of the different fracture types. Eur Spine J. 2000;9:123\u20138.","journal-title":"Eur Spine J"},{"key":"1911_CR19","doi-asserted-by":"publisher","first-page":"31","DOI":"10.1302\/0301-620X.50B1.31","volume":"50","author":"BL Cornish","year":"1968","unstructured":"Cornish BL. Traumatic spondylolisthesis of the axis. J Bone Joint Surg (Br). 1968;50:31\u201343.","journal-title":"J Bone Joint Surg (Br)"},{"key":"1911_CR20","doi-asserted-by":"publisher","first-page":"1299","DOI":"10.1007\/s00586-010-1401-2","volume":"19","author":"Y ElMiligui","year":"2010","unstructured":"ElMiligui Y, Koptan W, Emran I. Transpedicular screw fixation for type II Hangman\u2019s fracture: a motion preserving procedure. Eur Spine J. 2010;19:1299\u2013305.","journal-title":"Eur Spine J"},{"key":"1911_CR21","doi-asserted-by":"publisher","first-page":"88","DOI":"10.3171\/jns.1984.60.1.0088","volume":"60","author":"GM Borne","year":"1984","unstructured":"Borne GM, Bedou GL, Pinaudeau M. Treatment of pedicular fractures of the axis. J Neurosurg. 1984;60:88\u201393.","journal-title":"J Neurosurg"},{"key":"1911_CR22","doi-asserted-by":"crossref","unstructured":"Abumi K, Kaneda K. Pedicle screw fixation for nontraumatic lesions of the cervical spine. Spine (Phila Pa 1976). 1997;22:1853-1863.","DOI":"10.1097\/00007632-199708150-00010"},{"key":"1911_CR23","doi-asserted-by":"publisher","first-page":"77","DOI":"10.1097\/00003086-199902000-00009","volume":"359","author":"SC Ludwig","year":"1999","unstructured":"Ludwig SC, Kramer DL, Vaccaro AR, Albert TJ. Transpedicle screw fixation of the cervical spine. Clin Orthop Relat Res. 1999;359:77\u201388.","journal-title":"Clin Orthop Relat Res"},{"key":"1911_CR24","doi-asserted-by":"crossref","unstructured":"Ludwig SC, Kowalski JM, Edwards CC, Heller JG. Cervical pedicle screws: comparative accuracy of two insertion techniques. Spine (Phila Pa 1976). 2000;25:2675-2681.","DOI":"10.1097\/00007632-200010150-00022"}],"container-title":["Journal of Orthopaedic Surgery and Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13018-020-01911-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1186\/s13018-020-01911-3\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1186\/s13018-020-01911-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,8,31]],"date-time":"2021-08-31T20:39:35Z","timestamp":1630442375000},"score":1,"resource":{"primary":{"URL":"https:\/\/josr-online.biomedcentral.com\/articles\/10.1186\/s13018-020-01911-3"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,9,1]]},"references-count":24,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2020,12]]}},"alternative-id":["1911"],"URL":"https:\/\/doi.org\/10.1186\/s13018-020-01911-3","relation":{"has-preprint":[{"id-type":"doi","id":"10.21203\/rs.3.rs-29091\/v1","asserted-by":"object"},{"id-type":"doi","id":"10.21203\/rs.3.rs-29091\/v2","asserted-by":"object"}]},"ISSN":["1749-799X"],"issn-type":[{"value":"1749-799X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,9,1]]},"assertion":[{"value":"14 May 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"20 August 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"1 September 2020","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"This study was approved by the local Medical Ethics Committee, and informed consent was obtained from all individual participants included in the study.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Not applicable.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"None of the authors has any potential conflict of interest.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"372"}}