{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,21]],"date-time":"2026-04-21T04:09:38Z","timestamp":1776744578511,"version":"3.51.2"},"reference-count":24,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2020,11,17]],"date-time":"2020-11-17T00:00:00Z","timestamp":1605571200000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"},{"start":{"date-parts":[[2020,11,17]],"date-time":"2020-11-17T00:00:00Z","timestamp":1605571200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"publisher","award":["grant 30870647"],"award-info":[{"award-number":["grant 30870647"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"publisher"}]},{"name":"Dalian Medical Scientific Research Project","award":["grant 1811110"],"award-info":[{"award-number":["grant 1811110"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["J Orthop Surg Res"],"published-print":{"date-parts":[[2020,12]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Background<\/jats:title>\n                <jats:p>To evaluate the biomechanical properties of short-segment Schanz screw implanted in an oblique downward direction for the treatment of lumbar 1 burst fracture using a finite element analysis.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>The Universal Spine System (USS) fixation model for adjacent upper and lower vertebrae (T12 and L2) of lumbar 1 vertebra burst fracture was established. During flexion\/extension, lateral bending, and rotation, the screw stress and the displacement of bone defect area of the injured vertebrae were evaluated when the downward inserted angle between the long axis of the screws and superior endplate of the adjacent vertebrae was set to 0\u00b0 (group A), 5\u00b0 (group B), 10\u00b0 (group C), and 15\u00b0(group D). There were 6 models in each group.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>There were no significant differences in the maximum screw stress among all the groups during flexion\/extension, lateral bending, and rotation (<jats:italic>P<\/jats:italic>\u2009&gt;\u20090.05). There were no significant differences in the maximum displacement of the bone defect area of the injured vertebrae among all the groups during flexion\/extension, lateral bending, and rotation (<jats:italic>P<\/jats:italic>\u2009&gt;\u20090.05).<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusion<\/jats:title>\n                <jats:p>Short-segment Schanz screw implanted in an oblique downward direction with different angles (0\u00b0\/parellel, 5\u00b0, 10\u00b0, and 15\u00b0) did not change the maximum stress of the screws, and there was a lower risk of screw breakage in all groups during flexion\/extension, lateral bending, and rotation. In addition, the displacement of the injured vertebra defect area had no significant changes with the change of angles.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1186\/s13018-020-02024-7","type":"journal-article","created":{"date-parts":[[2020,11,17]],"date-time":"2020-11-17T17:20:42Z","timestamp":1605633642000},"update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":5,"title":["The feasibility of short-segment Schanz screw implanted in an oblique downward direction for the treatment of lumbar 1 burst fracture: a finite element analysis"],"prefix":"10.1186","volume":"15","author":[{"given":"Jifeng","family":"Liu","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sheng","family":"Yang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Fei","family":"Zhou","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jianmin","family":"Lu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chunyang","family":"Xia","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Huanhuan","family":"Wang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chao","family":"Chen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2020,11,17]]},"reference":[{"key":"2024_CR1","doi-asserted-by":"publisher","first-page":"e977","DOI":"10.1016\/j.wneu.2018.08.014","volume":"119","author":"S Yang","year":"2018","unstructured":"Yang S, Shang DP, Lu JM, Liu JF, Fu DP, Zhou F, Cong Y, Lv ZZ. Modified posterior short-segment pedicle screw instrumentation for lumbar burst fractures with incomplete neurological deficit. World Neurosurg. 2018;119:e977\u2013e85.","journal-title":"World Neurosurg"},{"key":"2024_CR2","doi-asserted-by":"publisher","first-page":"1113","DOI":"10.1016\/j.spinee.2017.03.022","volume":"17","author":"H Aono","year":"2017","unstructured":"Aono H, Ishii K, Tobimatsu H, Nagamoto Y, Takenaka S, Furuya M, Chiaki H, Iwasaki M. Temporary short-segment pedicle screw fixation for thoracolumbar burst fractures: comparative study with or without vertebroplasty. Spine J. 2017;17:1113\u20139.","journal-title":"Spine J"},{"key":"2024_CR3","doi-asserted-by":"publisher","first-page":"939","DOI":"10.1007\/s00402-018-2926-9","volume":"138","author":"RA Lindtner","year":"2018","unstructured":"Lindtner RA, Mueller M, Schmid R, Spicher A, Zegg M, Kammerlander C, Krappinger D. Monosegmental anterior column reconstruction using an expandable vertebral body replacement device in combined posterior-anterior stabilization of thoracolumbar burst fractures. Arch Orthop Trauma Surg. 2018;138:939\u201351.","journal-title":"Arch Orthop Trauma Surg"},{"key":"2024_CR4","doi-asserted-by":"publisher","first-page":"447","DOI":"10.1007\/s10143-011-0363-0","volume":"35","author":"T Miyashita","year":"2012","unstructured":"Miyashita T, Ataka H, Tanno T. Clinical results of posterior stabilization without decompression for thoracolumbar burst fractures: is decompression necessary? Neurosurg Rev. 2012;35:447\u201354 discussion 54-5.","journal-title":"Neurosurg Rev"},{"key":"2024_CR5","doi-asserted-by":"publisher","first-page":"43","DOI":"10.1186\/s13018-018-0743-z","volume":"13","author":"ZD Chen","year":"2018","unstructured":"Chen ZD, Wu J, Yao XT, Cai TY, Zeng WR, Lin B. Comparison of Wiltse\u2019s paraspinal approach and open book laminectomy for thoracolumbar burst fractures with greenstick lamina fractures: a randomized controlled trial. J Orthop Surg Res. 2018;13:43.","journal-title":"J Orthop Surg Res"},{"key":"2024_CR6","doi-asserted-by":"publisher","first-page":"e475","DOI":"10.1016\/j.wneu.2018.07.184","volume":"119","author":"K Wang","year":"2018","unstructured":"Wang K, Zhang ZJ, Wang JL, Huang CA, Huang QS, Chen J, Wu YS, Lin Y, Wang XY, Chen JX, Sheng SR. Risk factor of failed reduction of posterior ligamentatoxis reduction instrumentation in managing thoracolumbar burst fractures: a retrospective study. World Neurosurg. 2018;119:e475\u2013e81.","journal-title":"World Neurosurg"},{"key":"2024_CR7","doi-asserted-by":"publisher","first-page":"1741","DOI":"10.1097\/00007632-199408000-00014","volume":"19","author":"T McCormack","year":"1994","unstructured":"McCormack T, Karaikovic E, Gaines RW. The load sharing classification of spine fractures. Spine (Phila Pa 1976). 1994;19:1741\u20134.","journal-title":"Spine (Phila Pa 1976)"},{"key":"2024_CR8","doi-asserted-by":"publisher","first-page":"1003","DOI":"10.1097\/00007632-198809000-00007","volume":"13","author":"VK Goel","year":"1988","unstructured":"Goel VK, Kim YE, Lim TH, Weinstein JN. An analytical investigation of the mechanics of spinal instrumentation. Spine (Phila Pa 1976). 1988;13:1003\u201311.","journal-title":"Spine (Phila Pa 1976)"},{"key":"2024_CR9","doi-asserted-by":"publisher","first-page":"895","DOI":"10.1016\/0021-9290(80)90178-5","volume":"13","author":"RL Spilker","year":"1980","unstructured":"Spilker RL. Mechanical behavior of a simple model of an intervertebral disk under compressive loading. J Biomech. 1980;13:895\u2013901.","journal-title":"J Biomech"},{"key":"2024_CR10","doi-asserted-by":"crossref","unstructured":"Zhou F, Yang S, Liu J, Lu J, Shang D, Chen C, Wang H, Ma J. Finite element analysis comparing short-segment instrumentation with conventional pedicle screws and the Schanz pedicle screw in lumbar 1 fractures. Neurosurg Rev. 2020;43:301\u201312.","DOI":"10.1007\/s10143-019-01146-9"},{"key":"2024_CR11","doi-asserted-by":"publisher","first-page":"262","DOI":"10.1186\/s12891-017-1623-0","volume":"18","author":"JC Liao","year":"2017","unstructured":"Liao JC, Chen WP, Wang H. Treatment of thoracolumbar burst fractures by short-segment pedicle screw fixation using a combination of two additional pedicle screws and vertebroplasty at the level of the fracture: a finite element analysis. BMC Musculoskelet Disord. 2017;18:262.","journal-title":"BMC Musculoskelet Disord"},{"key":"2024_CR12","doi-asserted-by":"publisher","first-page":"884","DOI":"10.1016\/j.jbiomech.2009.01.017","volume":"42","author":"A Rohlmann","year":"2009","unstructured":"Rohlmann A, Zander T, Rao M, Bergmann G. Realistic loading conditions for upper body bending. J Biomech. 2009;42:884\u201390.","journal-title":"J Biomech"},{"key":"2024_CR13","doi-asserted-by":"publisher","first-page":"134","DOI":"10.1186\/s12891-016-0983-1","volume":"17","author":"D Kubosch","year":"2016","unstructured":"Kubosch D, Kubosch EJ, Gueorguiev B, Zderic I, Windolf M, Izadpanah K, Sudkamp NP, Strohm PC. Biomechanical investigation of a minimally invasive posterior spine stabilization system in comparison to the universal spinal system (USS). BMC Musculoskelet Disord. 2016;17:134.","journal-title":"BMC Musculoskelet Disord"},{"key":"2024_CR14","doi-asserted-by":"publisher","first-page":"1256","DOI":"10.1097\/00007632-198911000-00020","volume":"14","author":"I Yamamoto","year":"1989","unstructured":"Yamamoto I, Panjabi MM, Crisco T, Oxland T. Three-dimensional movements of the whole lumbar spine and lumbosacral joint. Spine (Phila Pa 1976). 1989;14:1256\u201360.","journal-title":"Spine (Phila Pa 1976)"},{"key":"2024_CR15","doi-asserted-by":"publisher","first-page":"578","DOI":"10.1097\/00007632-199403000-00014","volume":"19","author":"MM Panjabi","year":"1994","unstructured":"Panjabi MM, Oxland TR, Lin RM, McGowen TW. Thoracolumbar burst fracture. A biomechanical investigation of its multidirectional flexibility. Spine (Phila Pa 1976). 1994;19:578\u201385.","journal-title":"Spine (Phila Pa 1976)"},{"key":"2024_CR16","doi-asserted-by":"publisher","first-page":"e99156","DOI":"10.1371\/journal.pone.0099156","volume":"9","author":"C Li","year":"2014","unstructured":"Li C, Zhou Y, Wang H, Liu J, Xiang L. Treatment of unstable thoracolumbar fractures through short segment pedicle screw fixation techniques using pedicle fixation at the level of the fracture: a finite element analysis. PLoS One. 2014;9:e99156.","journal-title":"PLoS One"},{"key":"2024_CR17","doi-asserted-by":"publisher","first-page":"1005","DOI":"10.1177\/0954411914552308","volume":"228","author":"G Xu","year":"2014","unstructured":"Xu G, Fu X, Du C, Ma J, Li Z, Tian P, Zhang T, Ma X. Biomechanical comparison of mono-segment transpedicular fixation with short-segment fixation for treatment of thoracolumbar fractures: a finite element analysis. Proc Inst Mech Eng H. 2014;228:1005\u201313.","journal-title":"Proc Inst Mech Eng H"},{"key":"2024_CR18","doi-asserted-by":"publisher","first-page":"1005","DOI":"10.1016\/j.spinee.2017.10.064","volume":"18","author":"F De Iure","year":"2018","unstructured":"De Iure F, Lofrese G, De Bonis P, Cultrera F, Cappuccio M, Battisti S. Vertebral body spread in thoracolumbar burst fractures can predict posterior construct failure. Spine J. 2018;18:1005\u201313.","journal-title":"Spine J"},{"key":"2024_CR19","doi-asserted-by":"crossref","unstructured":"Liu J, Yang S, Lu J, Fu D, Liu X, Shang D. Biomechanical effects of USS fixation with different screw insertion depths on the vertebrae stiffness and screw stress for the treatment of the L1 fracture. J Back Musculoskelet Rehabil. 2018;31:285\u201397.","DOI":"10.3233\/BMR-169692"},{"key":"2024_CR20","doi-asserted-by":"publisher","DOI":"10.1016\/B978-012369390-7\/50003-4","volume-title":"Synthetic biomaterials for spinal applications","author":"S Brown","year":"2006","unstructured":"Brown S. Synthetic biomaterials for spinal applications. Burlington: Academic Press; 2006."},{"key":"2024_CR21","doi-asserted-by":"publisher","first-page":"e11244","DOI":"10.1097\/MD.0000000000011244","volume":"97","author":"H Wang","year":"2018","unstructured":"Wang H, Mo Z, Han J, Liu J, Li C, Zhou Y, Xiang L, Yang L. Extent and location of fixation affects the biomechanical stability of short- or long-segment pedicle screw technique with screwing of fractured vertebra for the treatment of thoracolumbar burst fractures: an observational study using finite element analysis. Medicine (Baltimore). 2018;97:e11244.","journal-title":"Medicine (Baltimore)"},{"key":"2024_CR22","doi-asserted-by":"publisher","first-page":"1003","DOI":"10.1016\/j.spinee.2009.08.457","volume":"9","author":"P Lakshmanan","year":"2009","unstructured":"Lakshmanan P, Jones A, Mehta J, Ahuja S, Davies PR, Howes JP. Recurrence of kyphosis and its functional implications after surgical stabilization of dorsolumbar unstable burst fractures. Spine J. 2009;9:1003\u20139.","journal-title":"Spine J"},{"key":"2024_CR23","doi-asserted-by":"publisher","first-page":"285","DOI":"10.1016\/j.spinee.2017.07.168","volume":"18","author":"HD Jang","year":"2018","unstructured":"Jang HD, Bang C, Lee JC, Soh JW, Choi SW, Cho HK, Shin BJ. Risk factor analysis for predicting vertebral body re-collapse after posterior instrumented fusion in thoracolumbar burst fracture. Spine J. 2018;18:285\u201393.","journal-title":"Spine J"},{"key":"2024_CR24","doi-asserted-by":"publisher","first-page":"32","DOI":"10.1186\/s13018-018-0733-1","volume":"13","author":"WT Zhao","year":"2018","unstructured":"Zhao WT, Qin DP, Zhang XG, Wang ZP, Tong Z. Biomechanical effects of different vertebral heights after augmentation of osteoporotic vertebral compression fracture: a three-dimensional finite element analysis. J Orthop Surg Res. 2018;13:32.","journal-title":"J Orthop Surg Res"}],"updated-by":[{"DOI":"10.1186\/s13018-020-02134-2","type":"correction","label":"Correction","source":"publisher","updated":{"date-parts":[[2020,12,24]],"date-time":"2020-12-24T00:00:00Z","timestamp":1608768000000}}],"container-title":["Journal of Orthopaedic Surgery and Research"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s13018-020-02024-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1186\/s13018-020-02024-7\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1186\/s13018-020-02024-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,1,4]],"date-time":"2021-01-04T16:16:09Z","timestamp":1609776969000},"score":1,"resource":{"primary":{"URL":"https:\/\/josr-online.biomedcentral.com\/articles\/10.1186\/s13018-020-02024-7"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,11,17]]},"references-count":24,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2020,12]]}},"alternative-id":["2024"],"URL":"https:\/\/doi.org\/10.1186\/s13018-020-02024-7","relation":{"correction":[{"id-type":"doi","id":"10.1186\/s13018-020-02134-2","asserted-by":"object"}]},"ISSN":["1749-799X"],"issn-type":[{"value":"1749-799X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,11,17]]},"assertion":[{"value":"15 June 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"14 October 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"17 November 2020","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"This study was approved by the Ethics Committee of Affiliated Zhongshan Hospital of Dalian University.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval and consent to participate"}},{"value":"Signed informed consent was obtained from each patient.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The authors indicated no potential conflicts of interest.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Competing interests"}}],"article-number":"537"}}